Jefferson Maintenance Facility Structural Drawings
This is a comprehensive set of structural design drawings and general notes prepared by Shive-Hattery for the Jefferson Maintenance Facility located at 610 North Pine Street, Jefferson, Iowa 50129, issued April 15, 2026 (Project No. BG-1D21-(000)-80-82). The documents establish the structural design criteria, material specifications, and construction requirements for a maintenance facility incorporating precast concrete shear walls, steel joists and beams, concrete foundations, and cast-in-place concrete slabs. The facility includes a garage with wash bay and brine bay areas requiring hot-dip galvanized structural elements, office space, and mechanical systems. The structural design is based on the 2024 International Building Code with seismic design category B and wind exposure category C (110 mph ultimate wind speed, 85 mph ASD wind speed). Live loads include standard roof loads of 20 psf, floor loads of 100 psf for stairs, and specialized loads such as 150 psf for mechanical rooms and 250 psf for heavy storage, with a maximum 2-ton crane hanger load of 11,400 lbs accommodated in specified bays.
The drawings specify concrete compressive strength of 4,000 psi for all structural concrete elements including footings, foundation walls, and slabs on grade. Structural steel conforms to ASTM A992 for wide flanges (Fy = 50 ksi) and ASTM A36 for angles and channels (Fy = 36 ksi), with all connections designed per AISC 360 specifications and utilizing A325 high-strength bolts. All structural steel in the wash bay and brine bay areas shall be hot-dip galvanized per ASTM A123, while steel outside these areas receives a zinc-rich rust-inhibitive primer. The geotechnical foundation design, based on a Terracon report dated October 14, 2024, establishes an allowable soil bearing pressure of 2,000 psf for spread and continuous wall footings, with minimum frost protection depths of 3 feet 6 inches for heated areas and 4 feet for unheated areas. Extensive quality assurance provisions require special inspection of concrete placement and compressive strength testing, structural steel welding and bolting (with non-destructive testing of complete penetration welds), masonry construction, and precast concrete erection, with all inspectors subject to qualification requirements including ACI, ICC, AWS, or ASNT certifications as applicable.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
1.
A.
B.
C.
D.
E.
F.
G.
H.
2.
A.
B.
C.
D.
E.
F.
G.
a.
b.
c.
3.
4.
CODES:
INTERNATIONAL BUILDING CODE (IBC) 2024
AMERICAN CONCRETE INSTITUTE - BUILDING CODE REQUIREMENTS FOR STRUCTURAL
CONCRETE (ACI 318)
AMERICAN CONCRETE INSTITUTE - BUILDING CODE REQUIREMENTS FOR MASONRY
STRUCTURES (ACI 530)
AMERICAN INSTITUTE OF STEEL CONSTRUCTION - SPECIFICATION FOR STRUCTURAL
STEEL BUILDINGS (AISC 360)
ALLOWABLE STRENGTH DESIGN (ASD)
AMERICAN SOCIETY OF CIVIL ENGINEERS AND STRUCTURAL ENGINEERING INSTITUTE
(ASCE/SEI 7) - MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES
AMERICAN WELDING SOCIETY D1.1
AMERICAN IRON AND STEEL INSTITUTE (AISI S100) SPECIFICATION FOR THE DESIGN OF
COLD FORMED STEEL STRUCTURAL MEMBERS
AMERICAN FOREST & PAPER ASSOCIATION (AF&PA) NATIONAL DESIGN SPECIFICATION
FOR WOOD CONSTRUCTION (NDS)
DESIGN LOADS PER THE 2024 IBC (RISK CATEGORY II)
DEAD LOADS
STRUCTURE SELF WEIGHT AS SHOWN
CEILING, MEP & FP 10 PSF
ROOFING SYSTEM 10 PSF
MEP ABOVE MECHANICAL ROOM 20 PSF
LIVE LOADS
TYPICAL ROOF LIVE LOAD 20 PSF
TYPICAL FLOOR LIVE LOADS (REDUCIBLE PER IBC 1607.10)
PARTITIONS 15 PSF
STAIRS STRUCTURE (UNREDUCIBLE) 100 PSF
STAIR TREADS 300 LBS OR 100 PSF
MECHANICAL ROOMS (UNREDUCIBLE) 150 PSF
HEAVY STORAGE (UNREDUCIBLE) 250 PSF
50' SPAN 2T MAX CRANE HANGER LOAD 11,400 LBS
ROOF SNOW LOAD
GROUND SNOW LOAD, Pg 25 PSF ROOF SNOW LOAD, Pf 20.0 PSF SNOW EXPOSURE FACTOR, Ce 0.90 SNOW IMPORTANCE FACTOR, Is 1.0 THERMAL FACTOR, Ct 1.0
SNOW DRIFT: REFER TO SNOW DRIFT DIAGRAM
WIND PRESSURE (ASCE 7-22)
WIND SPEED, Vult 110 MPH NOMINAL DESIGN WIND SPEED, Vasd 85 MPH
WIND EXPOSURE C
INTERNAL PRESSURE COEFFICIENT +/-0.18
MWFRS DESIGN WIND LATERAL PRESSURE 30 PSF
WIND PRESSURE - COMPONENTS AND CLADDING
PER ASCE 7-22 FOR EACH REQUIRED COMPONENT
SEE SHEET S002 FOR COMPONENTS AND CLADDING LOAD TABLE
SEISMIC DESIGN DATA
SEISMIC IMPORTANCE FACTOR - 1.0
MAPPED SPECTRAL RESPONSE ACCELERATIONS, Ss 0.058
MAPPED SPECTRAL RESPONSE ACCELERATIONS, S1 0.046
SITE CLASS D
SPECTRAL RESPONSE COEFFICIENTS, Sds - 0.062 SPECTRAL RESPONSE COEFFICIENTS, Sd1 - 0.073
SEISMIC DESIGN CATEGORY - B
BASIC SEISMIC FORCE-RESISTING SYSTEM:
PRECAST SHEAR WALLS
DESIGN BASE SHEAR, V = Cs x W 409 KIPS SEISMIC RESPONSE COEFFICIENT, Cs 0.333
RESPONSE MODIFICATION FACTOR, R 3
ANALYSIS PROCEDURE: - EQUIVALENT LATERAL FORCE
DEFLECTION CRITERIA
FLOOR LIVE LOAD - L/360
ROOF LIVE LOAD - L/240
TOTAL LOAD ON MEMBERS SUPPORTING MASONRY - L/600
SOILS INFORMATION BASED ON GEOTECHNICAL REPORT PREPARED BY TERRACON, REPORT
NO. AB245049-01, DATED OCTOBER 14, 2024.
NET ALLOWABLE SOIL BEARING PRESSURES:
SPREAD FOOTINGS - 2000 PSF
CONTINUOUS WALL FOOTINGS - 2000 PSF
MINIMUM FROST PROTECTION DEPTH MEASURED FROM GRADE
EXTERIOR FOOTING ADJACENT TO HEATED AREA (-3'-6")
EXTERIOR FOOTING AT UNHEATED AREA (-4'-0")
DESIGN INFORMATION
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.
ALL EXCAVATIONS SHALL BE PROPERLY AND SAFELY BACKFILLED. DO NOT PLACE BACKFILL
BEHIND BASEMENT WALLS OR RETAINING WALLS UNTIL CONCRETE HAS ATTAINED THE
SPECIFIED COMPRESSIVE STRENGTH. BASEMENT WALLS SHALL NOT BE BACKFILLED UNTIL
SUPPORTING FLOOR IS COMPLETED AND ATTAINED FULL STRENGTH. CONTRACTOR SHALL
PROTECT ALL BELOW GRADE WALLS FROM LATERAL EARTH PRESSURES UNTIL SUPPORTING
FLOOR STRUCTURE IS COMPLETED. CONTRACTOR PROVIDE FOR DESIGN, PERMITS AND
INSTALLATION OF LATERAL SHORING TO BRACE WALLS IN LIEU OF WAITING FOR FLOOR SLAB
COMPLETION.
FOOTING SHALL BE CENTERED UNDER WALLS AND COLUMNS UNLESS NOTED OTHERWISE.
CONTRACTOR SHALL ACCOUNT FOR PUMPING OF WATER FROM THE EXCAVATION DUE TO
SURFACE WATER, GROUND WATER AND SEEPAGE.
CONTRACTOR SHALL BE RESPONSIBLE FOR THE DESIGN AND INSTALLATION OF ALL SHEETING,
SHORING AND CRIBBING REQUIRED TO SAFELY RETAIN THE EARTH BANK AROUND THE
EXCAVATIONS.
ALL FOOTINGS SHALL BE PLACED ONTO FIRM UNDISTURBED SOIL OR ACCEPTABLE COMPACTED
BACKFILL AS OUTLINED IN THE SOIL REPORT AND PROJECT SPECIFICATIONS.
FOOTING ELEVATIONS SHOWN DESIGNATE THE MINIMUM DEPTH OF THE FOOTING WHERE THE
ALLOWABLE SOIL BEARING IS EXPECTED. LOCALIZED AREAS OF UNACCEPTABLE SOILS OR
POOR COMPACTION MAY BE DISCOVERED DURING THE EXCAVATION PROCESS REQUIRING
OVEREXCAVATION AND BACKFILL WITH ACCEPTABLE FILL. FOOTING EXCAVATIONS SHALL BE
LOWERED TO REACH SOIL MEETS THE DESIGN BEARING PRESSURE AND APPROVED BY THE
GEOTECHNICAL SPECIAL INSPECTION AGENCY.
ACCEPTABLE BACKFILL MATERIAL SHALL BE PLACED IN LIFTS NOT TO EXCEED EIGHT (8) INCHES
IN LOOSE THICKNESS.
FOR FOOTING AND FOUNDATIONS, THE SUBGRADE OR FILL MATERIAL SHALL BE COMPACTED
AND VERIFIED TO MEET 98% STANDARD PROCTOR MAXIMUM DRY DENSITY ACCORDANCE WITH
ASTM D698. FOR RELATIVELY COHESIONLESS GRANULAR FILL WHICH HAS A PERCENT PASSING
THE #200 SIEVE LESS THAN 10 PERCENT AND HAS ONLY A SLIGHT SENSITIVITY TO MOISTURE
CHANGES, COMPACTION SHALL BE 75 PERCENT RELATIVE DENSITY IN ACCORDANCE WITH
ASTM D4253 AND D4254. IF COMPACTION DOES NOT COMPLY, CONTRACTOR SHALL RECOMPACT
AREA AND UNTIL TEST RESULTS ARE PASSING. AN AREA EXHIBITING WEAKNESS SUCH AS
RUTTING OR PUMPING SHALL BE REMOVED AND REPLACED WITH COMPACTED GRANULAR FILL.
FOOTING EXCAVATIONS SHALL BE INSPECTED AND APPROVED BY THE GEOTECHNICAL SPECIAL
INSPECTION AGENCY BEFORE CONCRETE IS PLACED. CONTRACTOR SHALL NOTIFY INSPECTION
AGENCY WHEN EXCAVATION IS READY FOR TESTING. INSPECTION AGENCY SHALL PROVIDE A
WRITTEN REPORT OF TEST RESULTS AND COMPLIANCE TO THE OWNER.
ACCEPTABLE SOIL SHALL BE DEFINED AS MEETING ASTM D2487 SOIL CLASSIFICATION GROUPS
GW, GP, GM, SW, SP, SM OR A COMBINATION OF THESE TYPES.
UNACCEPTABLE SOILS SHALL BE DEFINED AS MEETING ASTM D2487 SOIL CLASSIFICATION
GROUPS GC, SC, ML, MH, CL, CH, OL, OH, PT OR A COMBINATION OF THESE TYPES. GROUPS CL AND ML MAY BE ACCEPTABLE IF THE LIQUID LIMIT IS LESS THAN 45 AND THE PLASTICITY INDEX
IS LESS THAN 20.
THE CONTRACTOR SHALL PROVIDE ALL NECESSARY MEASURES TO PREVENT ANY FROST OR
ICE FROM PENETRATING ANY FOOTING OR SLAB SUBGRADES BEFORE AND AFTER PLACING THE
CONCRETE AND UNTIL SUCH SUBGRADE IS FULLY PROTECTED BY THE PERMANENT BUILDING
ENCLOSURE AND THE SPACE IS CONDITIONED TO REMAIN ABOVE FREEZING.
CONCRETE FOOTINGS AND SLABS SHALL NOT BE PLACED ON OR AGAINST SUBGRADES
CONTAINING FROST, SNOW OR ICE. FROZEN SUBGRADES SHALL BE COMPLETELY THAWED AND
RECONDITIONED BEFORE CONCRETE MAY BE PLACED.
REPEATED HEAVY CONSTRUCTION TRAFFIC OVER EXPOSED SUBGRADE WILL CAUSE RUTTING
AND PUMPING WHEN SOIL IS ABOVE THE OPTIMUM MOISTURE CONTENT. AVOID EXCESS
CONSTRUCTION ACTIVITY ON WET SOILS. IF SUBGRADE IS ABOVE THE OPTIMUM MOISTURE
CONTENT DURING CONSTRUCTION, THEN DRYING OF THE SOIL SHALL BE CONDUCTED BY
DISKING, SCARIFICATION, AND AERATION.
SOILS WITH A MOISTURE CONTENT ABOVE THE OPTIMUM LEVEL SHALL BE REMOVED AND
REPLACED WITH COMPACTED GRANULAR FILL.
CONTRACTOR SHALL NOTIFY THE ARCHITECT AND ENGINEER OF ANY UNUSUAL SOIL
CONDITIONS THAT ARE IN VARIANCE WITH THE SOIL REPORT.
CONTRACTOR SHALL NOTIFY THE ARCHITECT AND ENGINEER IMMEDIATELY IF THE EXISTING
FOUNDATIONS VARY FROM THAT SHOWN ON THE DRAWINGS.
CONTRACTOR SHALL VERIFY OPENINGS AND SLEEVES THROUGH FOUNDATION WALLS WITH
THE ARCHITECTURAL, MECHANICAL AND ELECTRICAL REQUIREMENTS. CHANGES IN SIZE,
LOCATION AND NUMBER SHALL NOT BE PERMITTED WITHOUT WRITTEN APPROVAL BY THE
ENGINEER.
FOUNDATIONS
1.
2.
3.
4.
5.
6.
7.
8.
9.
ALL ORGANIC MATERIAL AND UNACCEPTABLE FILL MATERIAL SHALL BE REMOVED FROM
BENEATH THE SLAB ON GRADE AS DIRECTED IN THE SOIL REPORT. EXPOSED SUBGRADE SHALL
BE PROOF ROLLED WITH A HEAVY WEIGHTED VEHICLE OF ROLLER IN THE PRESENCE OF THE
GEOTECHNICAL SPECIAL INSPECTION AGENCY. AREAS EXHIBITING RUTTING, PUMPING OR
WEAKNESS SHALL BE REMOVED AND REPLACED WITH COMPACTED ACCEPTABLE FILL
MATERIAL.
COMPACTION SHALL BE TESTED AND VERIFIED TO MEET 98% STANDARD PROCTOR MAXIMUM
DRY DENSITY ACCORDANCE WITH ASTM D698. FOR RELATIVELY COHESIONLESS GRANULAR FILL
WHICH HAS A PERCENT PASSING THE #200 SIEVE LESS THAN 10 PERCENT AND HAS ONLY A
SLIGHT SENSITIVITY TO MOISTURE CHANGES, COMPACTION SHALL BE 75 PERCENT RELATIVE
DENSITY IN ACCORDANCE WITH ASTM D4253 AND D4254. IF COMPACTION DOES NOT COMPLY,
CONTRACTOR SHALL RECOMPACT AREA AND UNTIL TEST RESULTS ARE PASSING. AN AREA
EXHIBITING WEAKNESS SUCH AS RUTTING OR PUMPING SHALL BE REMOVED AND REPLACED
WITH COMPACTED GRANULAR FILL.
CONCRETE SLAB ON GRADE SHALL BE PLACED ON A 6" WELL GRADED COMPACTED GRANULAR
FILL SUB-BASE.
PLACE ALL SLABS ON GRADE WITH AN APPROVED JOINT PATTERN SUBMITTED BY CONTRACTOR
AND APPROVED BY ENGINEER OR AS SHOWN ON DRAWINGS. SEQUENCE OF CONSTRUCTION
AND CONTROL JOINTS SHALL BE PLACED TO MINIMIZE SHRINKAGE CRACKS.
CONCRETE SLAB ON GRADES SHALL HAVE CONTROL JOINTS SAW CUT OR TOOLED . LOCATE
JOINT ALONG COLUMN CENTER LINES WITH INTERMEDIATE JOINTS AT A MAXIMUM SPACING OF
36 TIMES THE SLAB THICKNESS, UNLESS NOTED OTHERWISE. SLAB JOINT PANELS SHALL HAVE A MAXIMUM LENGTH TO WIDTH RATIO OF 1.5:1. DO NOT STAGGER OR OFFSET JOINTS. PROVIDE
ADDITIONAL JOINTS AT RE-ENTRANT CORNER. IF RE-ENTRANT CORNERS ARE UNAVOIDABLE,
THEN ADDITIONAL REINFORCING COMPRISED OF (2) #4 BARS x 3'-0" SHALL BE PLACED IN THE
CENTER OF THE SLAB DIAGONAL TO THE RE-ENTRANT CORNER CONDITION. PROVIDE SHOP
DRAWING OF CONTROL JOINT PATTERN AND CORNER REINFORCING.
SAWCUT JOINTS AS SOON AS SURFACE WILL ALLOW WITHOUT EDGES RAVELING BUT PRIOR TO
THE NEXT DAY AFTER THE POUR.
FLOOR FINISHES SHALL BE STEEL TROWELED FOR ALL INTERIORS AND BROOM FINISHED FOR
ALL EXTERIORS UNLESS NOTED OTHERWISE.
UTILITY TRENCH BACKFILL UNDER THE SLAB ON GRADE SHALL MEET THE SAME COMPACTION
REQUIREMENTS AS THE ORIGINAL SUBGRADE LISTED ABOVE.
SLOPE SLABS TO DRAINS TO CREATE POSITIVE DRAINAGE. PROVIDE DEPRESSIONS WHERE
INDICATED ON ARCHITECTURAL DRAWINGS, WHILE MAINTAINING THE THICKNESS OF THE
CONCRETE SLAB.
FOUNDATIONS - SLAB ON GRADE
1.
2.
3.
4.
5.
6.
A.
B.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.
19.
DESIGN, FABRICATE, AND ERECT IN ACCORDANCE WITH THE LATEST EDITION OF STEEL JOIST
INSTITUTE'S, "STANDARD SPECIFICATIONS, LOAD TABLES AND WEIGHT TABLES FOR STEEL
JOISTS AND JOIST GIRDERS."
STEEL JOIST MANUFACTURER SHALL BE CERTIFIED BY THE STEEL JOIST INSTITUTE.
JOIST BRIDGING SIZE, TYPE, SPACING AND CONNECTIONS ARE TO BE DESIGNED AND PROVIDED
IN ACCORDANCE WITH CURRENT "SJI SPECIFICATIONS" AND OSHA REGULATIONS FOR TYPE OF
JOIST, SPACING, SPAN AND LOADING. NOT ALL JOIST BRIDGING HAS BEEN SHOWN ON THE
PLANS. LOCATE BRIDGING TO AVOID MECHANICAL OPENINGS AND DUCT WORK INDICATED ON
PLANS.
HANGING LOAD FROM THE JOISTS SHALL BE APPLIED ONLY AT PANEL POINTS AND ONLY WITH
ACCEPTABLE CONCENTRIC JOIST HANGER DEVICES. NO VERTICAL LOAD SHALL BE IMPOSED
ON THE BRIDGING.
UNLESS NOTED OTHERWISE, DESIGN ROOF JOISTS AND BRIDGING FOR A NET UPLIFT OF 15 PSF
WITHIN 9 FEET OF BUILDING EDGE AND 10 PSF ELSEWHERE.
BAR JOISTS SHALL BE DESIGNED TO RESIST THE FOLLOWING LATERAL (ROLLOVER) LOADS:
2 1/2" SEAT = 1600 LBS
5" SEAT = 500 LBS
PROVIDE SPECIAL JOISTS AND CONNECTIONS CAPABLE OF SUPPORTING THE DESIGN LOADS
INDICATED ON THE DRAWINGS. JOISTS SHALL HAVE VERTICAL LIVE LOAD DEFLECTIONS NO
GREATER THAN 1/360 OF SPAN FOR FLOOR JOIST AND 1/240 OF SPAN FOR ROOF JOISTS.
CONNECT STEEL JOISTS ACCORDING TO THIS TABLE. BOLTS AND WELDS ARE TO BE INSTALLED
ON BOTH SIDES OF JOIST SEATS.
WHERE COLUMNS ARE NOT FRAMED IN AT LEAST TWO DIRECTIONS WITH STRUCTURAL STEEL
MEMBERS, BOLT JOISTS TO STRUCTURAL FRAMING AT THE COLUMN LINES.
MANUFACTURE K-SERIES JOISTS ACCORDING TO STEEL JOIST INSTITUTE'S " STANDARD
SPECIFICATIONS FOR OPEN WEB STEEL JOISTS, K-SERIES."
MANUFACTURE LH-SERIES JOISTS ACCORDING TO STEEL JOIST INSTITUTES'S " STANDARD
SPECIFICATIONS FOR LONGSPAN STEEL JOISTS, LH-SERIES, AND DEEP LONGSPAN STEEL
JOISTS, DLH-SERIES.
CAMBER JOISTS ACCORDING TO SJI SPECIFICATIONS UNLESS NOTED OTHERWISE.
WHERE INDICATED, PROVIDE EXTENDED ENDS OF JOISTS WITH TYPE "R" EXTENDED ENDS
COMPLYING WITH "SJI SPECIFICATIONS."
WHERE INDICATED, PROVIDE TOP CHORD EXTENSION OF JOISTS WITH TYPE "S" TOP CHORD
EXTENSIONS COMPLYING WITH "SJI SPECIFICATIONS."
ALL BAR JOISTS IN THE WASH BAY AND BRINE BAY TO BE HOT DIP GALVANIZED. PRIME PAINT
ALL JOISTS WITH MANUFACTURER'S STANDARD, ZINC RICH, SHOP PRIMER COMPLYING WITH
PERFORMANCE REQUIREMENTS IN SSPC-PAINT 15.
FURNISH ALL MISCELLANEOUS ACCESSORIES INCLUDING HEADERS, CONNECTION PLATES AND
BOLTS.
INSTALL JOISTS AND ACCESSORIES PLUMB, SQUARE, AND TRUE TO LINE, SECURELY FASTEN TO
SUPPORTING CONSTRUCTION. INSTALL BRACING, BRIDGING, AND CONNECTIONS AND ANCHORS
TO ENSURE THAT JOISTS ARE STABILIZED DURING CONSTRUCTION.
INSTALL AND CONNECT BRIDGING CONCURRENTLY WITH JOIST ERECTION, BEFORE
CONSTRUCTION LOADS ARE APPLIED. ANCHOR ENDS OF BRIDGING LINES AT TOP AND BOTTOM
CHORDS IF TERMINATING AT WALLS OR BEAMS.
AFTER ERECTION, PROMPTLY CLEAN, PREPARE AND PRIME PAINT ALL CONNECTIONS, RUST
SPOTS, ABRADED SURFACES OF PRIME PAINTED JOISTS, BEARING PLATES ABUTTING
STRUCTURAL STEEL AND ACCESSORIES.
STEEL JOISTS
JOIST TYPE
K
LH/DLH 02-06
LH/DLH 07-17
LH/DLH 18-25
MINIMUM END BEARING
STEEL
2 1/2" 2 1/2" 4" 6"
MASONRY
4" 6" 6" 6"
WELD SIZE
1/8" 3/16" 1/4" 1/4"
WELD LENGTH
2" 2" 2" 4"
(MATERIAL)
1/2"(A307) 3/4"(A307) 3/4"(A307) 3/4"(A325)
WELD REQUIREMENTS BOLTS
STRUCTURAL STEEL
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
STRUCTURAL STEEL SHALL CONFORM TO THE REFERENCED EDITION OF THE AISC
"SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS".
STRUCTURAL STEEL MATERIAL STANDARDS
WIDE FLANGE SECTIONS ASTM A992 Fy = 50 KSI ANGLES, CHANNELS & PLATES ASTM A36 Fy = 36 KSI SQUARE AND RECTANGULAR HSS ASTM A500, GR C Fy = 50 KSI ROUND HSS - ASTM A500, GR C - Fy = 46 KSI
STRUCTURAL STEEL CONNECTION STANDARDS:
HIGH STRENGTH BOLTS ASTM F3125 GRADE A325
TENSION CONTROL BOLT/NUT/WASHER ASTM F1852
HEAVY HEX NUT ASTM A563
WASHERS ASTM F436
ANCHOR RODS ASTM F1554 GRADE 36
HEADED WELDED STUDS ASTM A108 TYPE B
WELDING ELECTRODES (CARBON STEEL) AWS 5.1, E70XX
WELDING SHALL BE IN ACCORDANCE WITH STRUCTURAL WELDING CODE, AWS D1.1, LATEST
EDITION, AND SHALL BE PERFORMED BY CERTIFIED WELDERS ONLY USING PROPER
ELECTRODES FOR MATERIAL BEING WELDED. PROVIDE WELD SIZE IN ACCORDANCE WITH AISC
SPECIFICATIONS, BUT NOT LESS THAN 3/16" FILLET, CONTINUOUS UNLESS OTHERWISE NOTED
ALL HIGH STRENGTH BOLTS SHALL BE INSTALLED IN ACCORDANCE WITH RCSC - "
SPECIFICATION FOR STRUCTURAL JOINTS USING ASTM A325 OR A490 BOLTS." SEE DRAWINGS
FOR BOLTS SIZES. USE 3/4" DIAMETER, A325 BOLTS UNLESS NOTED OTHERWISE.
WHEN TENSION CONTROL BOLTS ARE INDICATED "TC" ON THE DRAWINGS, PROVIDE HIGH
STRENGTH "TENSION CONTROLLED" BOLTS MEETING ASTM F1852, TYPE 1.
ALL BOLTED CONNECTIONS ARE BEARING TYPE, UNLESS INDICATED AS TENSION CONTROLLED
(TC) OR SLIP CRITICAL (SC). PROVIDE STANDARD HOLES FOR BEARING TYPE CONNECTION
WHICH ARE 1/16" WIDER DIAMETER THAN THE BOLT.
ALL STRUCTURAL STEEL FRAMING AND CONNECTORS IN THE WASH BAY AND BRINE BAY SHALL
BE HOT DIPPED GALVANIZED. ITEMS INDICATED TO BE GALVANIZED SHALL BE HOT-DIP
GALVANIZED IN COMPLIANCE WITH ASTM A123.
AFTER FABRICATION, ALL STEEL SHALL BE CLEANED OF ALL RUST, LOOSE MILL SCALE AND
OTHER FOREIGN MATERIALS. STEEL SHALL BE HAND TOOLED CLEANED (SSPC-SP2) OR POWER
TOOL CLEANED (SSPC-SP3).
ALL STRUCTURAL STEEL AND CONNECTORS OUTSIDE OF THE WASH AND BRINE BAYS TO
RECEIVE ONE COAT OF FABRICATOR'S STANDARD LEAD AND CHROMATE-FREE, ZINC RICH,
RUST INHIBITIVE PRIMER APPLIED PRIOR TO DELIVERY TO THE JOB SITE UNLESS NOTED
OTHERWISE. ALL AREAS OF STRUCTURAL STEEL MEMBERS IN WHICH THE PRIMER COATED
SURFACE IS DAMAGED DURING CONSTRUCTION SHALL BE TOUCHED UP WITH MATCHING
PRIMER.
THERE SHALL BE NO FIELD CUTTING OF STRUCTURAL STEEL MEMBERS FOR THE WORK OF
OTHER TRADES WITHOUT PRIOR WRITTEN APPROVAL OF THE STRUCTURAL ENGINEER OF
RECORD.
ALL MISCELLANEOUS STEEL AS SHOWN OR REFERENCED ON THE ARCHITECTURAL DRAWINGS
SHALL BE FABRICATED AND INSTALLED AS PART OF THE STRUCTURAL STEEL.
CONTRACTOR SHALL PROVIDE ALL TEMPORARY SHORES, GUYS, BRACES AND OTHER
SUPPORTS DURING ERECTION TO KEEP STRUCTURAL STEEL SECURE, PLUMB AND IN
ALIGNMENT AGAINST TEMPORARY CONSTRUCTION LOADS AND LOADS EQUAL TO DESIGN
LOADS. REMOVE ALL TEMPORARY SUPPORTS WHEN PERMANENT STRUCTURAL STEEL
FRAMING AND CONNECTIONS ARE COMPLETED.
MAINTAIN ERECTION TOLERANCES OF STRUCTURAL STEEL WITHIN AISC 303, "CODE OF
STANDARD PRACTICE FOR STEEL BUILDINGS AND BRIDGES."
DO NOT ENLARGE MISALIGNED BOLT HOLES BY BURNING OR THERMAL CUTTING. REAM HOLES
THAT MUST BE ENLARGED TO INSTALL BOLTS.
1.
2.
3.
4.
5.
A.
B.
a.
b.
C.
a.
b.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
ALL CONCRETE SHALL CONFORM TO THE LATEST REQUIREMENTS OF THE AMERICAN
CONCRETE INSTITUTES PUBLICATIONS: ACI 301, ACI 305.1, ACI 306.1, ACI 315, AND ACI 318
UNLESS NOTED OTHERWISE.
CONCRETE COMPRESSIVE STRENGTH (28 DAY)(F'c)
FOOTINGS - 4000 PSI
FOUNDATION WALLS AND PIERS - 4000 PSI
SLAB ON GRADE - 4000 PSI
ELEVATED SLAB ON DECK - 4000 PSI
CONCRETE REINFORCEMENT STANDARDS:
DEFORMED BARS - ASTM A615 - Fy = 60 KSI WELDED WIRE REINFORCEMENT (WWR) - ASTM A1064 - Fy = 65 KSI
ALL CONCRETE SHALL BE STONE AGGREGATE UNLESS NOTED OTHERWISE. SUBMIT MIX DESIGN
AND DOCUMENTATION FOR APPROVAL PER ACI 318.
REINFORCEMENT PROTECTION
CONCRETE PLACED AGAINST EARTH - 3"
CONCRETE PLACED IN FORMS BUT EXPOSED TO WEATHER OR EARTH:
BARS #5 AND SMALLER - 1 1/2"
BARS LARGER THAN #5 - 2"
CONCRETE NOT EXPOSED TO WEATHER OR IN CONTACT WITH GROUND:
SLABS, WALLS, AND JOISTS - 3/4"
BEAMS, COLUMNS - 1 1/2"
WHERE REQUIRED, DOWELS SHALL MATCH THE SIZE, NUMBER AND SPACING OF THE MAIN
REINFORCING UNLESS NOTED OTHERWISE.
ALL SPLICES, STANDARD HOOKS, AND DEVELOPMENT LENGTHS TO BE PER THE REFERENCED
EDITION OF ACI 318. MAKE BARS CONTINUOUS AROUND CORNERS. ALL SPLICES SHALL BE BY
CONTACT LAP.
ALL SPLICES SHALL BE A CLASS "B" TENSION SPLICE AS DEFINED IN ACI 318. PROVIDE LAP
SPLICES LENGTHS AS FOLLOWS:
LAP SPLICE LENGTHS GIVEN, ASSUME CLEAR SPACING BETWEEN BARS OF 2 BAR DIAMETERS,
AND A MINIMUM CLEAR COVER OF 1 BAR DIAMETER. TOP BARS ARE DEFINED AS HORIZONTAL
BARS WITH MORE THAN 12" ON FRESH CONCRETE BENEATH THE BARS.
WALLS AND GRADE BEAMS SHALL NOT HAVE JOINTS IN A HORIZONTAL PLANE, UNLESS
APPROVED BY THE ENGINEER.
CONSTRUCTION JOINTS IN STRUCTURAL CONCRETE WORK MUST BE MADE AT CENTER OF
SPAN OR AT CENTER OF SUPPORT WITH VERTICAL BULKHEADS AND HORIZONTAL KEYS,
UNLESS OTHERWISE SHOWN.
THERE SHALL BE NO ADDITIONAL OPENINGS LARGER THAN 10" IN CONCRETE WALLS AND SLABS
NOT SHOWN. REFER TO CONCRETE OPENING DETAIL FOR ADDITIONAL REINFORCEMENT
AROUND OPENINGS.
REINFORCING STEEL SHALL BE SECURELY FASTENED INTO FORMS PRIOR TO POURING
CONCRETE. WET SETTING OF REINFORCING STEEL WILL NOT BE ACCEPTED PER ACI.
CONCRETE MIX - FOUNDATIONS
COARSE AGGREGATE - 100% PASSING 1" SIEVE
FINE AGGREGATE - 100% PASSING 3/8" SIEVE
WATER/CEMENT RATIO - 0.45
SLUMP (NO WATER REDUCER) - 4" +/- 1"
SLUMP (WITH WATER REDUCER) - 4" TO 8"
AIR CONTENT - 6% +/- 1.5%
CONCRETE MIX - SLAB ON GRADE - INTERIOR
COARSE AGGREGATE - 100% PASSING 1" SIEVE
FINE AGGREGATE - 100% PASSING 3/8" SIEVE
WATER/CEMENT RATIO - 0.5
SLUMP (WITH WATER REDUCER) - 4" TO 6"
AIR CONTENT - LESS THAN 3%
CONCRETE MIX - TOPPING SLAB AND PAN STAIR FILL
COARSE AGGREGATE - 100% PASSING 1/2" SIEVE
FINE AGGREGATE - 100% PASSING NO.8 SIEVE
WATER/CEMENT RATIO - 0.5
SLUMP (WITH WATER REDUCER) - 5" TO 8"
AIR CONTENT - LESS THAN 3%
CAST-IN-PLACE CONCRETE
BAR SIZE
#3 #4 #5 #6 #7 #8 #9 #10 #11
TYPICAL
19" 25" 31" 37" 54" 62" 70" 79" 87"
TOP BARS
25" 33" 41" 49" 71" 81" 91" 102" 114"
4000 PSI
ABBREVIATIONS
A
ADD'L ADDITIONAL
ADD ADDENDUM
AFF ABOVE FINISHED FLOOR
AL ALUMINUM
ALT ALTERNATE
APPROX APPROXIMATE (LY)
ARCH ARCHITECT (URAL)
B
B/ BOTTOM OF
BLDG BUILDING
BM BEAM
BOT BOTTOM
BP BASE PLATE
BRG BEARING
BSMT BASEMENT
BTWN BETWEEN
BF BEAM FLANGE WIDTH
C
CFCI CONTRACTOR FURNISHED
CONTRACTOR INSTALLED
CIP CAST-IN PLACE
CJ CONSTRUCTION/CONTROL JOINT
CL CENTER LINE
CLR CLEAR (ANCE)
CMU CONCRETE MASONRY UNIT
COL COLUMN
CONC CONCRETE
CONN CONNECT (ION) (ED) (OR)
CONT CONTINUOUS
CONST CONSTRUCTION
COORD COORDINATE
CFSF COLD FORMED STEEL FRAMING
D
D DEPTH
DBE DECK BEARING ELEVATION
DBL DOUBLE
DEG DEGREE
DEMO DEMOLITION
DIA DIAMETER
DIM DIMENSION
DN DOWN
DTL DETAIL
DWG DRAWING
DWL DOWEL
E E or EXST EXISTING
E/ EDGE OF
EA EACH
EF EACH FACE
EJ EXPANSION JOINT
ELEC ELECTRIC / ELECTRICAL
ELEV or EL ELEVATION
EMBED EMBEDDED
EOR ENGINEER OR RECORD
EQ EQUAL
EQUIP EQUIPMENT
ES EACH SIDE
EW EACH WAY
F
F ISOLATED FOOTING
F'C CONCRETE COMPRESSIVE
STRENGTH
F/ FACE OF
FC CONCRETE COMPRESSIVE
STRENGTH
FDN FOUNDATION
FF FINISHED FLOOR
FFE FINISH (ED) FLOOR ELEVATION
FLR FLOOR (ING)
FP FIRE PROTECTION
FRP FIBER REINFORCED POLYMER
FTG FOOTING
FV FIELD VERIFY
FY YIELD STRENGTH
G GA GAGE or GAUGE
GALV GALVANIZED
GB GRADE BEAM
GC GENERAL CONTRACTOR
G or GL GRID LINE
GRD GRAD (E) (ING)
H
HC HOLLOW CORE
HDR HEADER
HGR HANGER
HK HOOK
HORIZ HORIZONTAL
HT HEIGHT
HWS HEADED WELDED STUDS
I
ID INSIDE DIAMETER
J
JBE JOIST BEARING ELEVATION
JST JOIST (S)
JT JOINT
K
KO KNOCK-OUT
L L or LNTL LINTEL
LF LINEAR FOOT
LLBB LONG LEG BACK TO BACK
LLOS LONG LEG OUTSTANDING
LLH LONG LEG HORIZONTAL
LLV LONG LEG VERTICAL
LONG LONGITUDE (INAL)
LSL LONG SLOTTED (HOLES)
LVL LEVEL (ER) or LAMINATED VENEER
LUMBER
M
MATL MATERIAL
MAX MAXIMUM
MECH MECHANICAL
MEMB MEMBRANE
MEP MECHANICAL, ELECTRICAL,
PLUMBING
MEZZ MEZZANINE
MFRG MANUFACTURING
MFR MANUFACTURER
MID MIDDLE
MIN MINIMUM
MISC MISCELLANEOUS
MK MARK
MO MASONRY OPENING
MTL METAL
N
NA NOT APPLICABLE
NIC NOT IN CONTRACT
NTS NOT TO SCALE
O
O/O OUT TO OUT
OC ON CENTER
OD OUTSIDE DIAMETER
OF OUTSIDE FACE
OFCI OWNER FURNISHED-CONTRACTOR
INSTALLED
OFOI OWNER FURNISHED-OWNER
INSTALLED
OH OPPOSITE HAND
OPNG OPENING (S)
ORIG ORIGINAL
OVHD OVERHEAD
P
PAF POWDER ACTUATED FASTENER
PC PRECAST CONCRETE or PILE CAP
PED PEDESTAL
PERF PERFORATED
PERIM PERIMETER
PERP PERPENDICULAR
PH PHASE
PL PLATE
PLYWD PLYWOOD
PREFAB PREFABRICATED
PRELIM PRELIMINARY
PVC POLYVINYL CHLORIDE
Q
QTY QUANTITY
R
R RADIUS
RD ROOF DRAIN
REF REFER (ENCE)
REINF REINFORCE (D) (ING) (MENT)
REQD REQUIRED
RF RETAINING FOUNDATION
RO ROUGH OPENING
RTU ROOF TOP UNIT
S
SC SLIP CRITICAL
SCH or SCHED SCHEDULE
SECT SECTION
SEOR STRUCTURAL ENGINEER OF RECORD
SIM SIMILAR
SJ SAW CUT JOINT or SLIP JOINT
SLBB SHORT LEG BACK TO BACK
SLOS SHORT LEG OUTSTANDING
SLP SLOPE
SOG SLAB ON GRADE
SPC SPACE (ING)
SPEC SPECIFICATIONS
SS STAINLESS STEEL
SSL SHORT SLOTTED (HOLES)
STA STATION
STAG STAGGERED
STD STANDARD
STIFF STIFFENER
STL STEEL
STRUC STRUCTURE (AL)
T
T&B TOP AND BOTTOM
T&G TONGUE AND GROOVE
T/ TOP OF
TC TENSION CONTROLLED BOLT
TEMP TEMPORARY
TF TRENCHED FOUNDATION
THK THICK (NESS)
TOT TOTAL
TRANS TRANSVERSE
TYP TYPICAL
U
UNO UNLESS NOTED OTHERWISE
V
VERT VERTICAL
W
W/ WITH
W/O WITHOUT
WD WIDTH or WOOD
WF WALL FOOTING
WP WORKING POINT
WWR WELDED WIRE REINFORCEMENT
WWF WELDED WIRE FABRIC
MASONRY
STEEL
MISCELLANEOUS
CONCRETE
EARTH
GRANULAR FILL
GROUT
HIDDEN LINE
L(+100'-0") (+99'-0")
CHANGE IN SLAB ELEVATION MARK
W10 x4
9(E
BP2
STRUCTURAL COLUMN DESIGNATION
(E) - EXISTING
(D) - DEMOLISHED
BASE PLATE MARK
F # (+X'-X") P # (+X'-X")
FOOTING MARK (TOP ELEVATION)
BRICK LEDGE STEP MARK
PIER MARK (TOP ELEVATION)
SPAN DIRECTION MARK - ONE WAY
SPAN DIRECTION MARK - ONE WAY
SPAN DIRECTION MARK - TWO WAY
SLAB EXTENTS - ORTHOGONAL OR SLANTED
SHAFT OPENING
MOMENT FRAMING CONNECTION MARK
CANTILEVER FRAMING CONNECTION MARK
SPLICE FRAMING CONNECTION MARK
MOMENT SPLICE FRAMING
CONNECTION MARK
SHEAR TRANSFER MARK
UPPER ELEVATION
LOWER ELEVATION
W(+100'-2")
(+100'-0") WALL STEP MARK
UPPER ELEVATION
LOWER ELEVATION
(+95'-0")
(+97'-0") FOUNDATION STEP MARK
UPPER ELEVATION
LOWER ELEVATION
GENERAL SYMBOLS LEGEND
NORTH ARROW
0A1 VIEW NAME
1/8" = 1'-0" 12" Contributor 1 / Contributor 2 / Contributor 3
VIEW NUMBER
DRAWING SCALE
TRUE NORTH
NORTH
PLAN
SHEET NUMBER
BUILDING SECTION MARK
A1 A101
A000
A1 A101
A1 A101
A1 A101
INTERIOR ELEVATION MARK
VIEW NUMBER
SHEET NUMBER
A101 A1
A00 KEYNOTE VALUE
RFI
REVISION NUMBER
REVISION TYPE
D.8
D.8
EXISTING GRID ID MARK
NEW GRID ID MARK
100'-0"
FIRST FLOOR
IDENTIFIED LEVEL NAME
ELEVATION MARK
SPOT ELEVATION MARK100'-0"
ROOM NAME
101 ROOM NUMBER
GENERAL SYMBOLS LEGEND
VIEW NUMBER
SHEET NUMBER
WALL SECTION MARK
VIEW NUMBER
A101 A1
SHEET NUMBER
DETAIL SECTION MARK
VIEW NUMBER
SHEET NUMBER
ENLARGED DETAIL MARK
VIEW NUMBER
MATCHLINE
SHEET NUMBER
EXTERIOR ELEVATION MARK
VIEW NUMBER
A4/S104
VIEW NUMBER / SHEET NUMBER
OF CONTINUING VIEW
A1
A1
A1
A1
1.
2.
3.
4.
5.
6.
7.
8.
9.
A.
B.
C.
D.
10.
A.
B.
C.
11.
12.
13.
14.
15.
16.
17.
18.
THE GENERAL STRUCTURAL NOTES ARE INTENDED TO SUPPLEMENT THE DRAWINGS AND
SPECIFICATIONS. SHOULD CONFLICTS EXIST BETWEEN THESE DRAWINGS AND THE
SPECIFICATIONS NOTIFY THE ENGINEER OF ANY SUCH CONFLICTS.
STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH ALL PROJECT DRAWINGS AND
SPECIFICATIONS. REFER TO ALL DRAWINGS FOR THE COORDINATION OF THE WORK IN THIS
PROJECT.
THE INTENT OF THESE PLANS AND NOTES IS TO PRESENT THE PROJECT REQUIREMENTS.
MAJOR DETAILS HAVE BEEN SHOWN ON THE DRAWINGS. HOWEVER, CERTAIN MINOR DETAILS
MUST BE WORKED OUT IN THE FIELD OR SHOP DRAWING PROCESS BY THE CONTRACTOR.
ELEVATIONS GIVEN ON PLANS ARE IN REFERENCE TO THE FINISHED FLOOR ELEVATION (+
100'-0") WHICH IS EQUAL TO THE CIVIL DATUM OF (1057.50').
UNLESS NOTED OTHERWISE, DETAILS SHOWN ON DRAWINGS ARE TO BE CONSIDERED TYPICAL
FOR ALL SIMILAR CONDITIONS.
THE STRUCTURE IS DESIGNED TO BE STABLE AND SELF-SUPPORTING AFTER THE BUILDING IS
FULLY ERECTED AND ALL CONNECTIONS ARE COMPLETED. UNLESS NOTED OTHERWISE, THE
DRAWINGS DO NOT INDICATE THE MEANS AND METHODS OF CONSTRUCTION. IT IS SOLELY THE
CONTRACTOR'S RESPONSIBILITY TO DETERMINE THE ERECTION PROCEDURE AND
SEQUENCING TO ENSURE THE SAFETY OF THE BUILDING AND ITS COMPONENT PARTS DURING
ERECTION. THIS INCLUDES THE ADDITION TEMPORARY BRACING, GUYS AND TIE-DOWNS
NECESSARY FOR THE ERECTION PROCESS.
IT IS SOLELY THE CONTRACTOR'S RESPONSIBILITY TO FOLLOW THE APPLICABLE SAFETY
CODES AND REGULATIONS DURING ALL PHASES OF CONSTRUCTION.
CONTRACTOR'S CONSTRUCTION AND ERECTION SEQUENCE SHALL CONSIDER THE EFFECTS OF
THERMAL MOVEMENTS OF THE STRUCTURAL ELEMENTS DURING THE CONSTRUCTION PERIOD.
EXISTING CONDITIONS:
THE CONTRACTOR IS RESPONSIBLE FOR VERIFYING ALL DIMENSIONS AND CONDITIONS
RELATING TO EXISTING CONSTRUCTION AND EXISTING SERVICES ON SITE. THE
CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND LOCATIONS OF EXISTING COLUMNS,
WALLS, OPENINGS, ETC, WITH THE ARCHITECTURAL DRAWINGS PRIOR TO PROCEEDING
WITH THE WORK. ANY DISCREPANCIES WITH THE CONTRACT DOCUMENTS SHALL BE
REPORTED TO THE ARCHITECT AND ENGINEER BEFORE PROCEEDING WITH THE AFFECTED
PART OF THE WORK.
DURING CONSTRUCTION THE CONTRACTOR MAY ENCOUNTER EXISTING CONDITIONS
WHICH ARE NOT KNOWN OR ARE AT VARIANCE WITH PROJECT DOCUMENTATION
(DISCOVERY). SUCH CONDITIONS MAY INTERFERE WITH THE NEW CONSTRUCTION OR
REQUIRE PROTECTION AND/OR SUPPORT OF EXISTING WORK DURING CONSTRUCTION. IT
MAY ALSO CONSIST OF DAMAGED OR DETERIORATION OF STRUCTURAL MATERIALS OR
COMPONENTS WHICH COULD JEOPARDIZE THE STRUCTURAL INTEGRITY OF THE
BUILDING(S). THE CONTRACTOR SHALL NOTIFY THE ENGINEER OF ALL DISCOVERIES WHICH
MAY INTERFERE WITH THE PROPER EXECUTION OF THE WORK OR JEOPARDIZE THE
STRUCTURAL INTEGRITY OF THE BUILDING(S) PRIOR TO PROCEEDING WITH THE WORK
RELATED TO SUCH DISCOVERIES.
DURING THE CONSTRUCTION PROCESS, IT SHALL BE SOLELY THE CONTRACTOR'S
RESPONSIBILITY TO MAINTAIN THE INTEGRITY OF THE EXISTING STRUCTURE AND TO
PROTECT IT FROM DAMAGE ANY PORTIONS THAT ARE TO REMAIN.
CONTRACTOR SHALL INVESTIGATE THE SITE DURING EARTHWORK OPERATIONS FOR FILL
MATERIAL OR BURIED STRUCTURES. IMMEDIATELY, NOTIFY THE ENGINEER IF ANY SUCH
MATERIALS OR STRUCTURES ARE DISCOVERED.
STRUCTURAL COORDINATION
MECHANICAL, ELECTRICAL OR PLUMBING LOADS, OPENINGS AND SUPPORT FRAMING ARE
SHOWN FOR BIDDING PURPOSES ONLY. CONTRACTOR SHALL OBTAIN APPROVAL OF THE
MECHANICAL, ELECTRICAL OR PLUMBING CONTRACTOR BEFORE PROCEEDING WITH SUCH
PORTION OF THE WORK.
THE CONTRACTOR SHALL VERIFY THE SIZE AND LOCATION OF ALL OPENINGS, HOLES AND
SLEEVES THROUGH FOUNDATIONS AND OTHER STRUCTURAL ELEMENTS WITH THE
MECHANICAL, ELECTRICAL AND PLUMBING CONTRACTORS. NO OPENINGS SHALL PASS
THROUGH STRUCTURAL MEMBERS UNLESS SHOWN ON THE DRAWINGS OR APPROVED BY
THE ENGINEER.
EXCESS COST DUE TO VARIATION IN THE STRUCTURE TO ACCOMMODATE A SUBSTITUTION
OR ALTERNATE MANUFACTURER(S) FROM THE LISTED BASIS OF DESIGN SHALL BE BORNE
BY THE CONTRACTOR.
BEFORE SUBMITTING A BID, EACH BIDDER SHALL VISIT THE SITE AND BECOME FULLY
ACQUAINTED WITH THE EXISTING CONDITIONS, CONSTRUCTION REQUIREMENTS,
RESTRICTIONS, QUANTITIES AND EQUIPMENT NECESSARY TO COMPLETE THE WORK. THE BID
SHALL INCLUDE ALL ITEMS REQUIRED TO COMPLETE THE WORK WITHIN THE EXISTING
CONDITIONS. DISRUPTION OF THE OWNERS NORMAL ACTIVITIES AROUND THE CONSTRUCTION
SITE SHALL BE KEPT TO A MINIMUM.
THE COST OF ADDITIONAL DESIGN WORK DUE TO ERRORS AND OMISSIONS BY THE
CONTRACTOR DURING CONSTRUCTION SHALL BE BORNE BY THE RESPONSIBLE CONTRACTOR.
ANY ENGINEERING DESIGN PROVIDED BY OTHER AND SUBMITTED FOR REVIEW OR RECORD
SHALL BEAR THE STAMP AND SIGNATURE OF A PROFESSIONAL STRUCTURAL ENGINEER
REGISTERED IN THE STATE WHERE THE PROJECT EXISTS.
CONTRACTOR SHALL COORDINATE WORK SCHEDULES WITH THE OWNER TO ESTABLISH
CONSTRUCTION SEQUENCING AROUND ANY OCCUPIED AREAS. CONTRACTOR SHALL NOT
PROCEED TO OCCUPIED AREAS UNTIL AUTHORIZED BY THE OWNER.
ALL ELEMENTS AND SURFACES DAMAGED BY DEMOLITION, BUT NOT SCHEDULED FOR
REMOVAL SHALL BE REPAIRED AND REFINISHED TO MATCH THE ADJACENT SURFACES AT NO
ADDITIONAL COST TO THE OWNER.
CONTRACTOR SHALL REMOVE ALL DEBRIS AND WASTE MATERIALS RESULTING FROM
CONSTRUCTION FROM THE SITE, UNLESS NOTED OTHERWISE.
CONTRACTOR SHALL MINIMIZE CREATION OF DUST, DIRT AND WINDBORNE DEBRIS FROM
BLOWING ACROSS THE SITE AND ONTO ADJACENT SITES.
CONTRACTOR SHALL COVER ANY EXTERIOR OPENING WITH TEMPORARY CLOSURES WHEN
NOT WORKING ON SITE TO PROTECT THE INTERIOR SPACES FROM WEATHER, INSECTS,
RODENTS AND INTRUDERS.
GENERAL NOTES
SHEET
DATE:
R
EV
IS
IO
N S:
COUNTY: DISTRICT:
PROJECT NUMBER:
Resources & Acquisitions Bureau 800 Lincoln Way Ames, Iowa 50010
(515) 239-1299
Iowa | Illinois | Indiana | Nebraska
4125 Westown Pkwy, Suite 100 | West Des Moines, IA 50266
515.223.8104 | www.shive-hattery.com
SHIVE-HATTERY PROJECT NO:
BG-1D21-(000)-80-82
4/
/2
4:
:3
PM
JE
FF
ER
SO
N M
AI
N
TE
N
AN
C
E
FA
C
IL
IT
Y
ST
R
U C
TU
R
AL
G
EN
ER
AL
IN
FO
R
M
AT
IO
N
N O
R
TH
P
IN
E
ST
JE
FF
ER
SO
N , I
A
15 APR 2026
S000
GREENE 01
2240013090
N O
D
AT
E:
BY
D
ES
C R
IP
TI
O N
FOR REFERENCE ONLY
SHOWN AS AN EXAMPLE OF THE TYPE AND SCOPE
OF CONSTRUCTION ANTICIPATED IN ALTON, IA
1.
2.
3.
4.
5.
6.
7.
A.
B.
8.
A.
B.
9.
10.
11.
12.
13.
14.
ALL METAL DECK SHALL BE DESIGNED, MANUFACTURED, AND INSTALLED IN ACCORDANCE WITH
THE LATEST PROVISIONS OF THE STEEL DECK INSTITUTE - "DESIGN MANUAL FOR COMPOSITE
DECKS, FORM DECKS, ROOF DECKS AND CELLULAR METAL FLOOR DECK WITH ELECTRICAL
DISTRIBUTION" AND UNDERWRITER REQUIREMENTS (I.E. FACTORY MUTUAL).
STEEL DECK AND ACCESSORIES SHALL BE FABRICATED FROM STEEL SHEETS CONFORMING TO
THE FOLLOWING STANDARDS:
PAINTED STEEL ROOF DECK ASTM A1008, GR 33
GALVANIZED STEEL ROOF DECK ASTM A653, GR 33
COMPOSITE STEEL FLOOR DECK ASTM A653, GR 50 [40]
PROVIDE METAL DECK MANUFACTURED BY A MEMBER OF THE STEEL DECK INSTITUTE OF THE
TYPE AND GAUGE INDICATED ON THE DRAWINGS.
GALVANIZED STEEL ROOF, FLOOR AND COMPOSITE DECK SHALL BE SHEET MATERIAL
CONFORMING TO ASTM A924 WITH A MINIMUM G60 COATING.
MINIMUM DECK BEARING ON STEEL MEMBERS SHALL BE 1 1/2". INSTALL DECK WITH A MINIMUM
2" END LAPS CENTERED OVER SUPPORT MEMBERS. COMPOSITE FLOOR DECK ENDS SHALL NOT
BE LAPPED.
DECK MANUFACTURER SHALL PROVIDE ALL RIDGE AND VALLEY PLATES, FLOOR DECK FILLERS,
AND COLUMN CLOSURES NECESSARY TO COMPLETE THE DECK INSTALLATION. ALL DECK AND
ACCESSORIES SHALL BE GALVANIZED, 20 GA. MINIMUM.
WHERE NOT INDICATED IN THE DRAWINGS, ATTACH ROOF DECK TO SUPPORTING STEEL
MEMBERS WITH EITHER PUDDLE WELDS OR POWDER ACTUATED FASTENERS:
(4) 5/8" DIAMETER PUDDLE WELDS PER 36 INCH WIDE SHEET (36/4 PATTERN). FASTEN
SIDELAPS CONDITIONS WITH #10 SELF DRILLING SCREWS, MINIMUM OF ONE SCREW AT
EACH MID SPAN OR AT 24" ON CENTER MAXIMUM . ATTACH DECK TO EDGES AT MEMBERS
PARALLEL TO CORRUGATIONS WITH 5/8" DIAMETER PUDDLE WELDS AT MINIMUM 6" ON
CENTER.
APPROVED EQUIVALENT POWDER ACTUATED FASTENERS THAT MEET THE SAME CAPACITY
VALUES AS WELDED CONNECTIONS.
WHERE NOT INDICATED IN THE DRAWINGS, ATTACH FLOOR DECK TO SUPPORTING STEEL
MEMBERS WITH PUDDLE WELDS.
(4) 5/8" DIAMETER PUDDLE WELDS PER 36 INCH WIDE SHEET (36/4 PATTERN). ATTACH DECK
TO EDGE ANGLES AND MEMBERS PARALLEL TO CORRUGATIONS WITH 5/8" DIAMETER
PUDDLE WELDS AT MINIMUM 12" ON CENTER. CONNECT DECK SIDE LAP WITH #10 TEK
SCREWS AT 1/2 THE SPAN OR 36" ON CENTER.
HEADED WELDED STUD INSTALLATION MAY BE SUBSTITUTED FOR WELDED DECK
FASTENING REQUIREMENTS.
DO NOT HANG ANY PIPING, DUCT WORK OR EQUIPMENT GREATER THAN 50LBS FROM STEEL
ROOF DECK.
FLOOR DECKING DEPTH AND GAGES SHOWN HAVE BEEN DESIGNED TO SUPPORT THE WEIGHT
OF WET CONCRETE PLUS A CONSTRUCTION LIVE LOAD OF 20 PSF WITHOUT INTERMEDIATE
SHORING BASED ON A MINIMUM THREE SPAN CONDITION. AREAS WHICH REQUIRE ONE OR TWO
SPAN CONDITIONS BASED ON THE SHOP DRAWING LAYOUT, SHALL BE INVESTIGATED BY THE
MANUFACTURER FOR DEFLECTION AND ALLOWABLE STRESSES. IF DEFLECTION EXCEEDS 1/180
THE SPAN OR THE ALLOWABLE STRESSES OF THE DECK THEN SHORING SHALL BE INDICATED
ON THE SHOP DRAWINGS FOR THOSE LOCATIONS.
AFTER DECK INSTALLATION, PREPARE AND REPAIR DAMAGED GALVANIZED COATINGS ON BOTH
SURFACES OF THE DECK WITH GALVANIZED REPAIR PAINT ACCORDING TO ASTM A780 AND
MANUFACTURER'S WRITTEN INSTRUCTIONS.
AFTER PAINTED DECK INSTALLATION, CLEAN RUST SPOTS, WELDS AND ABRADED SURFACES OF
PAINTED DECK. APPLY REPAIR PAINT OF SAME COLOR AND TYPE AS MANUFACTURER'S SHOP
PRIMED DECK.
VERIFY ALL OPENING SIZES AND LOCATIONS WITH THE APPROPRIATE TRADES. REINFORCE
DECK OPENINGS FROM SIX (6) INCHES TO TWELVE (12) INCHES IN SIZE WITH L2x2x1/4 STEEL
ANGLES. PLACE FRAMING ANGLES PERPENDICULAR TO FLUTES, EXTEND A MINIMUM TWO (2)
FLUTES BEYOND EACH SIDE OF OPENING AND WELD TO DECK AT EACH FLUTE. REFER TO
TYPICAL DETAIL FOR LARGER OPENINGS.
ALL DECK IN GARAGE AREA TO BE ACOUSTICAL DECK. DECK IN WASH BAY AND BRINE BAY TO
BE HOT DIP GALVANIZED AND HAVE ENCAPSULATED INSULATION. ACOUSTICAL DECK IN REST
OF GARAGE AREA TO HAVE A ZINC RICH PRIMER AND THE INSULATION DOES NOT NEED TO BE
ENCAPSULATED. STANDARD ROOF DECK (NON-ACOUSTICAL) OVER THE OFFICE SPACE TO BE
STANDARD PRIMER PAINTED.
STEEL DECK
1.
2.
A.
a.
3.
A.
B.
4.
A.
a.
b.
c.
d.
e.
f.
5.
A.
B.
6.
A.
B.
C.
7.
A.
B.
8.
A.
9.
A.
a.
b.
c.
d.
e.
CONRACTOR SHALL SUBMIT FOR REVIEW AND APPROVAL THE FOLLOWING SUBMITTALS FOR
EACH MATERIAL INDICATED BELOW.
CONCRETE REINFORCING
SUBMIT CONCRETE REINFORCEMENT SHOP DRAWINGS IN ACCORDANCE WITH ACI 315 FOR
APPROVAL.
DETAIL BARS IN ACCORDANCE WITH "ACI DETAILING MANUAL", PUBLICATION SP-66 AND
THE LATEST EDITION OF ACI 318 "BUILDING CODE REQUIREMENTS FOR REINFORCED
CONCRETE".
CAST-IN-PLACE CONCRETE
SUBMIT CONCRETE MIX DESIGNS FOR EACH APPLICATION LOCATION INDICATED IN THE
DRAWINGS.
SUBMIT SHOP DRAWING OF EMBEDDED STEEL ELEMENTS AND CONNECTIONS.
PRECAST STRUCTURAL CONCRETE
PROVIDE PRECAST STRUCTURAL CONCRETE SHOP DRAWINGS WHICH INCLUDE THE
FOLLOWING:
PLANS INDICATING MEMBER SIZES, LOCATIONS, DIMENSIONS, OPENING LOCATIONS
SUPPORT CONDITIONS AND REINFORCEMENT.
DETAIL CONNECTIONS AT MEMBER ENDS AND ADJACENT CONSTRUCTION.
TYPE, SIZE AND LENGTH OF WELDED CONNECTIONS.
LOCATIONS AND DETAILS OF ANCHORAGE DEVICES TO BE EMBEDDED IN OR ATTACHED
TO STRUCTURE OR OTHER CONSTRUCTION.
INDICATE LOCATION, DIMENSIONS AND DETAILS OF CORNER UNITS AND SPECIAL
SHAPES AND JOINTS.
PROVIDE ENGINEERING DESIGN ANALYSIS AND CALCULATIONS DATA SIGNED AND
SEALED BY THE QUALIFIED PROFESSIONAL ENGINEER LICENSED IN THE STATE WHERE
THE PROJECT IS LOCATED.
CONCRETE UNIT MASONRY
SUBMIT CONCRETE MASONRY UNIT PRODUCT DATA, INDICATING COMPRESSIVE STRENGTH
OF UNITS, MORTAR AND GROUT.
SUBMIT SHOP DRAWINGS WITH PLANS AND ELEVATIONS INDICATING CONTROL JOINTS AND
STEEL REINFORCING TO BE INSTALLED IN WALL. INDICATE SIZE, LOCATIONS, BAR LENGTHS
AND SPLICING LENGTHS.
STRUCTURAL STEEL
STRUCTURAL STEEL SHOP DRAWINGS SHOWING COMPLETE DIMENSIONS, DETAILS, SIZES,
AND GRADES OF STEEL MEMBERS AND CONNECTIONS, SIZE, TYPE, AND NUMBER OF
WELDS SHALL BE PREPARED AND SUBMITTED FOR APPROVAL PRIOR TO FABRICATION OF
STEEL COMPONENTS.
STRUCTURAL STEEL SHOP DRAWINGS SHALL BE DETAILED IN COMPLIANCE WITH THE AISC
"DETAILING FOR STEEL CONSTRUCTION". STRUCTURAL STEEL SHALL BE FABRICATED AND
ERECTED IN COMPLIANCE WITH AISC 360 - "SPECIFICATION FOR STRUCTURAL STEEL
BUILDINGS."
CONNECTION DESIGN: SUBMIT DESIGN AND DETAILS OF STRUCTURAL CONNECTIONS
REQUIRED BY THE CONTRACT DOCUMENTS TO BE SELECTED AND COMPLETED BY THE
STRUCTURAL STEEL FABRICATOR, INCLUDING COMPREHENSIVE ENGINEERING ANALYSIS
BY A QUALIFIED REGISTERED STRUCTURAL ENGINEER LICENSED IN THE STATE WHERE
THE PROJECT IS LOCATED. CONNECTION SHALL BE DESIGNED AND DETAILED TO
WITHSTAND THE FORCES AND DESIGN CRITERIA INDICATED ON DRAWINGS.
STEEL JOISTS
SUBMIT BAR JOIST SHOP DRAWING WITH PLANS INDICATING LAYOUT, SIZE DESIGNATIONS,
SPAN LENGTHS, SPACINGS, BRIDGING REQUIREMENTS AND CONNECTION CONDITIONS.
SUBMIT COMPREHENSIVE ENGINEERING DESIGN ANALYSIS OF SPECIAL JOISTS SIGNED
AND SEALED BY THE QUALIFIED PREOFESSIONAL ENGINEER.
STEEL DECKING
SUBMIT STEEL DECK SHOP DRAWING INDICATING PLANS, SIZES, LENGTHS, SPACINGS,
BEARING CONDITIONS AND CONNECTION REQUIREMENTS.
COLD FORMED STEEL FRAMING
PROVIDE COLD FORMED STEEL FRAMING SHOP DRAWINGS WHICH INCLUDE THE
FOLLOWING:
PLANS INDICATING MEMBER SIZES, LOCATIONS, DIMENSIONS, OPENING LOCATIONS
SUPPORT CONDITIONS AND WEB REINFORCEMENT.
DETAIL CONNECTIONS AT MEMBER ENDS AND ADJACENT CONSTRUCTION.
TYPE, SIZE AND LENGTH OF WELDED CONNECTIONS.
LOCATIONS AND DETAILS OF ANCHORAGE DEVICES TO BE EMBEDDED IN OR ATTACHED
TO STRUCTURE OR OTHER CONSTRUCTION.
PROVIDE ENGINEERING DESIGN ANALYSIS AND CALCULATIONS DATA SIGNED AND
SEALED BY THE QUALIFIED PROFESSIONAL ENGINEER LICENSED IN THE STATE WHERE
THE PROJECT IS LOCATED.
SUBMITTALS
1.
2.
A.
B.
C.
D.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
DESIGN STRUCTURAL PRECAST TO COMPLY WITH ACI 318 AND PCI MNL 120, "PCI DESIGN
HANDBOOK - PRECAST AND PRESTRESSED CONCRETE." PRECAST STRUCTURAL CONCRETE
COMPONENTS SHALL BE DESIGNED BY THE PRECAST MANUFACTURER'S QUALIFIED
STRUCTURAL ENGINEER LICENSED IN THE STATE WHERE THE PROJECT IS LOCATIONS.
PROVIDE COMPREHENSIVE ENGINEERING ANALYSIS AND DESIGN USING PERFORMANCE
REQUIREMENTS AND DESIGN CRITERIA INDICATED IN THE DRAWINGS AND SPECIFICATIONS.
PRECAST STRUCTURAL CONCRETE MATERIAL STANDARDS:
MINIMUM 28 DAY COMPRESSIVE STRENGTH: 5,000 PSI
REINFORCING BARS: ASTM A615 60,000 PSI
LOW-ALLOY WELDABLE REINFORCING BARS: ASTM A706 60,000 PSI
PRESTRESSING STEEL WIRE, MIN ULTIMATE STRENGTH ASTM A416 270,000 PSI
PRECAST MANUFACTURER SHALL BE A PCI CERTIFIED PLANT. PRECAST STRUCTURAL
CONCRETE COMPONENTS SHALL BE FABRICATED TO COMPLY WITH PCI MNL 116, "MANUAL
FOR QUALITY CONTROL FOR PLANTS AND PRODUCTION OF STRUCTURAL PRECAST CONCRETE
PRODUCTS."
DESIGN PRECAST STRUCTURAL CONCRETE FRAMING SYSTEM AND CONNECTIONS TO
MAINTAIN CLEARANCES AT OPENINGS, TO ALLOW FOR FABRICATION AND CONSTRUCTION
TOLERANCES, TO ACCOMMODATE LIVE LOAD DEFLECTIONS, SHRINKAGE, CREEP AND OTHER
BUILDING MOVEMENTS. MAINTAIN DEFLECTION LIMITS OF ACI 318
FABRICATOR SHALL BE A PCI CERTIFIED PLANT UNDER GROUP C and CA.C3(A) - PRESTRESSED
STRAIGHT STRAND STRUCTURAL MEMBERS
PRECAST INSTALLER/ERECTOR SHALL BE PCI CERTIFIED (CATEGORY S2 - COMPLEX) TO ERECT
STRUCTURAL SYSTEMS.
FURNISH ALL LOOSE CONNECTION HARDWARE AND ANCHORAGE ITEMS TO BE EMBEDDED IN
OR ATTACHED TO OTHER CONSTRUCTION AHEAD OF THOSE CONSTRUCTION SEQUENCES.
PROVIDE LOCATION, SETTING DIAGRAMS, TEMPLATES, AND INSTALLATION INSTRUCTIONS.
ALL PRECAST BEARING CONDITIONS SHALL USE A BEARING PAD AS RECOMMENDED BY THE
PRECAST MANUFACTURER FOR THE APPLICATION. STEEL SHIMS ARE NOT ALLOWED.
CAST-IN ANCHORS, INSERTS, PLATES ANGLES OR OTHER ANCHORAGE HARDWARE WITH
SUFFICIENT ANCHORAGE AND EMBEDMENT TO COMPLY WITH DESIGN REQUIREMENTS.
CAST-IN OPENINGS LARGER THAN 100 SQUARE INCHES (10"x10"). PROVIDE FIELD CUT OPENING
SIZES AND LOCATION ON THE SHOP DRAWING SUBMITTAL FOR PRECAST MANUFACTURERS
REVIEW AND APPROVAL.
DO NOT INSTALL PRECAST CONCRETE UNITS UNTIL SUPPORTING STRUCTURE IS COMPLETE
AND STRUCTURALLY READY TO RECEIVE LOADS FROM PRECAST. CAST-IN-PLACE CONCRETE
SHALL HAVE ACHIEVED SPECIFIED DESIGN STRENGTH WITH TESTING CONFIRMATION
PERFORMED.
ERECT PRECAST STRUCTURAL CONCRETE LEVEL, PLUMB, AND SQUARE WITHIN ACI
TOLERANCES. PROVIDE TEMPORARY FRAMING, SHORING, AND BRACING AS REQUIRED TO
MAINTAIN POSITION, STABILITY AND ALIGNMENT OF UNITS UNTIL PERMANENT CONNECTIONS
ARE COMPLETED.
CLEAN EXPOSED SURFACES OF PRECAST CONCRETE UNITS AFTER ERECTION AND
COMPLETION OF THE JOINT GROUTING. REMOVE WELD SLAG, STAINS, DIRT AND OTHER
DELETERIOUS MATERIAL.
REFER TO ARCHITECTURAL DRAWINGS FOR EXPOSED SURFACE FINISHES, TEXTURES,
REVEALS, ETC.
PRECAST STRUCTURAL CONCRETE
1.
2.
3.
4.
5.
6.
7.
A.
B.
C.
D.
E.
8.
9.
10.
11.
A.
B.
C.
D.
12.
13.
14.
15.
A.
B.
C.
D.
E.
F.
16.
17.
CONCRETE MASONRY UNIT STANDARDS AND COMPRESSIVE STRENGTHS:
DESIGN ASSEMBLY STRENGTH, F'm , BY UNIT STRENGTH METHOD 2500 PSI
CONCRETE MASONRY UNITS (NORMAL WEIGHT) ASTM C90 3250 PSI
MASONRY GROUT ASTM C476 2500 PSI
MASONRY MORTAR, TYPE S ASTM C270 1800 PSI
REINFORCING FOR MASONRY ASTM A615 Fy = 60 KSI
PLATE AND BENT BAR ANCHORS ASTM A36
WIRE MESH TIES ASTM A185
JOINT REINFORCEMENT, LADDER TYPE, 1.7(9GA) ASTM A1064
ANCHOR RODS FOR MASONRY ASTM A307
THE LOAD BEARING CONCRETE MASONRY WALLS FOR THIS PROJECT WERE DESIGNED TO
SPAN VERTICALLY AND BE BRACED BY THE ROOF AND FLOOR FRAMING ELEMENTS OF THE
STRUCTURE. DURING CONSTRUCTION THE MASONRY CONTRACTOR SHALL PROVIDE LATERAL
BRACING UNTIL THE ROOF STRUCTURE IS INSTALLED AS RECOMMENDED BY ACI 530 AND THE
LATEST REVISION OF "STANDARD PRACTICE FOR BRACING MASONRY WALLS UNDER
CONSTRUCTION", PREPARED BY THE COUNCIL FOR MASONRY WALL BRACING. THIS BRACING IS
TO PREVENT UNNECESSARY STRESS OR DAMAGE TO THE MASONRY WALLS FROM LATERAL
LOADS, WHICH CAN OCCUR WHILE THE WALLS ARE NOT PROPERLY BRACED BY THE ROOF AND
FLOOR STRUCTURE.
SPLICE REINFORCING USING CONTACT LAPS TO THE LENGTHS INDICATED BELOW:
NP = NOT PERMITTED
NOTES TO SPECIFIER:
BASED ON 100% ALLOWABLE TENSILE STRESS IN REINFORCING (24,000 PSI)
LAP SPLICE CAN BE REDUCED (DIV BY 1.5) IF STRESS IS LESS THAN 80%
BARS GREATER THAN #9 ARE REQUIRED TO BE MECHANICALLY SPLICED
MASONRY MATERIALS AND CONSTRUCTION SHALL COMPLY WITH THE REQUIREMENTS OF
“SPECIFICATION FOR MASONRY STRUCTURES AND RELATED COMMENTARIES (ACI 530/ASCE
6/TM 602) PUBLISHED BY AMERICAN CONCRETE INSTITUTE, EXCEPT WHERE REQUIREMENTS
ARE EXCEEDED BY THESE CONTRACT DOCUMENTS.
THOROUGHLY MIX MORTAR AND GROUT INGREDIENTS IN ACCORDANCE WITH THE
REFERENCED ASTM ABOVE IN QUANTITIES NEEDED FOR IMMEDIATE USE. DO NOT USE ANTI-
FREEZE COMPOUNDS TO LOWER THE FREEZE POINT.
ALL LOAD BEARING MASONRY WALLS SHALL BE HAVE FULL MORTAR BED, HEAD AND COLLAR
JOINTS. LAY HOLLOW MASONRY UNITS WITH FACE SHELL BEDDING ON HEAD AND BED JOINTS.
HORIZONTAL JOINT REINFORCEMENT: ALL LOAD BEARING MASONRY WALLS SHALL BE
CONSTRUCTED WITH LADDER TYPE JOINT REINFORCEMENT AS FOLLOWS:
SPACED AT A MAXIMUM OF 16" ON CENTER IN WALL CONSTRUCTION.
LAP JOINT REINFORCEMENT ENDS MINIMUM 6 INCHES.
PLACE HORIZONTAL JOINT REINFORCEMENT ONE ROW ABOVE AND ONE ROW BELOW ALL
WALL OPENINGS.
PLACE CONTINUOUS JOINT REINFORCEMENT IN FIRST JOINT BELOW THE TOP OF THE WALL.
DO NOT CONTINUE HORIZONTAL JOINT REINFORCEMENT ACROSS CONTROL OR EXPANSION
JOINTS.
ALL LOAD BEARING REINFORCED UNIT MASONRY WALLS SHALL HAVE (1) #5 BAR VERTICALLY IN
GROUTED CELL AT ALL CORNERS, ENDS OF WALLS, WALL INTERSECTIONS, AND IMMEDIATELY
ADJACENT TO EACH SIDE OF CONTROL JOINTS AND WALL OPENINGS.
CONCRETE MASONRY UNIT CORES SHALL BE PLACED WITH CELLS IN VERTICAL ALIGNMENT. ALL
CORES CONTAINING REINFORCEMENT AND ANCHORS SHALL BE FILLED SOLID WITH GROUT.
GROUT ALL CELLS TO RECEIVE ANCHORS.
PROVIDE A MINIMUM OF 1/2" OF GROUT BETWEEN THE MAIN REINFORCING AND THE MASONRY
UNITS. ALL VERTICAL REINFORCEMENT SHALL BE CENTERED IN THE WALL UNLESS NOTED
OTHERWISE.
ALL MASONRY WALLS SHALL HAVE VERTICAL CONTROL JOINTS AT A MAXIMUM SPACING OF 25
FEET AS FOLLOWS:
COORDINATE CONTROL JOINTS WITH LOCATIONS INDICATED ON ARCHITECTURAL
DRAWINGS.
CONTROL JOINTS SHALL NOT INTERFERE WITH BEAMS, JOISTS, OR LINTEL BEARING.
PROVIDE PREFORMED EXTRUDED RUBBER CONTROL JOINT DESIGNED FOR MASONRY
WALLS CONFORMING TO ASTM D2000 2AA-805.
SEAL JOINT WITH SINGLE COMPONENT ELASTERMERIC POLYURETHANE SEALANT. COLOR
TO MATCH MORTAR JOINTS.
DOWELS IN FOOTINGS SHALL BE PLACED TO ALIGN WITH CORES CONTAINING REINFORCING
STEEL. COORDINATE PLACEMENT BEFORE CONSTRUCTION OF FOOTING BEGINS.
GROUT SOLID ALL CMU CORES BELOW ADJACENT GRADE OR BELOW SLAB ON GRADE
CONSTRUCTION.
DURING CONSTRUCTION OF WALLS, COVER TOPS OF WALLS, PARTIALLY COMPLETED MASONRY
AND ANY OPEN WALL CAVITIES AT SILLS OR HEADERS WITH WATERPROOF SHEETING AT THE
END OF EACH DAY'S WORK.
MASONRY WALL CONSTRUCTION TOLERANCES
MAXIMUM VARIATION FROM UNIT TO UNIT: 1/16"
MAXIMUM VARIATION FROM PLANE OF WALL: 1/4"
MAXIMUM VARIATION FROM PLUMB: 1/4"
MAXIMUM VARIATION FROM LEVEL COURSING: 1/8"
MAXIMUM VARIATION OF JOINT THICKNESS: 1/8"
MAXIMUM VARIATION FROM CROSS SECTIONAL THICKNESS OF WALL: 1/4"
REINFORCE ALL NON-LOAD BEARING MASONRY WALLS (SHOWN ON ARCHITECTURAL
DRAWINGS) WITH #5 BARS AT XX" OC UNLESS NOTED OTHERWISE.
BEAM BEARING CONDITIONS: FILL BLOCK CELLS SOLID WITH GROUT A DISTANCE OF 24"
BENEATH AND 12" EACH SIDE OF BEAM REACTIONS OR OTHER CONCENTRATED LOADS IF NOT
OTHERWISE REINFORCED. ALL BEAM AND JOIST POCKETS SHALL BE GROUTED SOLID OR
FILLED WITH CONCRETE MASONRY UNITS AFTER STEEL ERECTION IS COMPLETE.
REINFORCED UNIT MASONRY
BAR SIZE
#3 #4 #5 #6 #7 #8 #9
6" CMU
27" 36" 45" 54"
NP
NP
NP
8" CMU
27" 36" 45" 54" 63" 113"
NP
10" CMU
27" 36" 45" 54" 63" 72" 82"
12" CMU
27" 36" 45" 54" 63" 72" 82"
MINIMUM LAP SPLICE LENGTH
1.
2.
3.
4.
5.
6.
7.
8.
PROVIDE LINTELS ABOVE ALL WALL OPENINGS AND RECESSES GREATER THAN 12" WIDE AS
INDICATED IN THE PLANS AND LINTEL SCHEDULE.
OPENINGS NOT IDENTIFIED ON THE DOCUMENTS SHALL BE CONSTRUCTED IN A SIMILAR
MANNER TO THE SCHEDULED LOCATIONS THAT MATCH SPAN AND LOAD CONDITIONS. CONTACT
STRUCTURAL ENGINEER FOR CONFIRMATION.
LINTELS FOR 8" WIDE CMU NON-LOAD BEARING MASONRY PARTITION WALLS SHALL HAVE
LINTELS IN ACCORDANCE WITH THE FOLLOWING SCHEDULE:
ALL CMU BOND BEAM LINTELS SHALL HAVE A MINIMUM (2) #5 BARS PLACED 3" FROM THE
BOTTOM OF THE BLOCK AND GROUTED SOLID.
ALL STEEL ANGLE LINTELS ARE LONG LEG BACK TO BACK AND STITCH WELDED TOGETHER TOP
AND BOTTOM 3" LONG AT 12" ON CENTER MINIMUM.
ALL BOND BEAM LINTELS SHALL BE CONSTRUCTED USING BOND BEAM UNITS.
WALL OPENING JAMBS SHALL BE GROUTED SOLID FULL HEIGHT BELOW THE WIDTH OF THE
LINTEL BEARING, UNLESS NOTED OTHERWISE.
ALL LINTELS SHALL HAVE A MINIMUM OF 8" END BEARING, UNLESS NOTED OTHERWISE.
ALL STEEL LINTEL ASSEMBLIES IN EXTERIOR WALL CONSTRUCTION SHALL BE HOT-DIP
GALVANIZED PER ASTM A123, UNLESS NOTED OTHERWISE.
BEARING PLATES NOT REQUIRED FOR STEEL LINTELS, UNLESS NOTED OTHERWISE.
REINFORCED UNIT MASONRY - LINTELS
OPENING WIDTH MASONRY OPTION STEEL OPTION
1'-0 TO 2'-0"
>2'-0" TO 4'-0"
>4'-0" TO 6'-0"
>6'-0" TO 8'-0"
8" DEEP BOND BEAM 5/16"x7"PLATE (2)L3 1/2x3 1/2x1/4
(2)L4x3 1/2x5/16(LLV) (2)L5x3 1/2x5/16(LLV)
8" DEEP BOND BEAM
8" DEEP BOND BEAM
16" DEEP BOND BEAM
SHEET
DATE:
R
EV
IS
IO
N S:
COUNTY: DISTRICT:
PROJECT NUMBER:
Resources & Acquisitions Bureau 800 Lincoln Way Ames, Iowa 50010
(515) 239-1299
Iowa | Illinois | Indiana | Nebraska
4125 Westown Pkwy, Suite 100 | West Des Moines, IA 50266
515.223.8104 | www.shive-hattery.com
SHIVE-HATTERY PROJECT NO:
BG-1D21-(000)-80-82
4/
/2
4:
:4
PM
JE
FF
ER
SO
N M
AI
N
TE
N
AN
C
E
FA
C
IL
IT
Y
ST
R
U C
TU
R
AL
G
EN
ER
AL
IN
FO
R
M
AT
IO
N
S
PE
C
IA
L
IN
SP
EC
TI
O N
S
N O
R
TH
P
IN
E
ST
JE
FF
ER
SO
N , I
A
15 APR 2026
S001
GREENE 01
2240013090
7. The contractor is responsible for testing services that are required for material submittals and that not part of the special inspections program (e.g. aggregate tests, concrete mix designs, testing of controlled fill, materials, etc.).
6. The special inspection and quality assurance program does not relieve the contractor of his or her responsibility to perform quality control.
5. When deficiencies are identified, the contractor must take corrective actions to comply with the contract documents or remedy the deficiencies as directed by the registered design professional.
4. The contractor must cooperate with the inspections and testing agencies. Safe access must be provided to all inspection and test to be performed. This may require the contractor to provide scaffolding, ladders or lifts.
3. The contractor is responsible for scheduling inspections and tests. Sufficient notice and lead time must be allowed for the inspection and testing to be performed without impending construction operations.
2. Pre-construction meeting is to be conducted by the contractor with meeting minutes to be taken and distributed to all members attending. Meeting minutes to include a sign-in sheet for all parties.
1. The Contractor is responsible for scheduling a pre-construction meeting (scheduled at least 5 business days before start of construction). Meeting should include all responsible parties (A/E, SI's, Field Inspector). Meeting is for entire project, not phase of work.
CONTRACTOR'S RESPONSIBILITY REGARDING INSPECTIONS
6. Each Contractor responsible for the construction or fabrication of a system or component described above must submit a Statement of Responsibility.
I. Foundation design: Cast in place reinforced concrete on aggregate piers.
H. Critical support systems and connections and debris impact protection of the components and connections:
All critical systems are within shelter enclosure.
G. Corrosion resistance or protection of exposed metal connectors providing load path continuity: NA F. Wall cladding and wall cladding connections: NA
E. Main windforce-resisting system connections to the foundation: Field welded steel embeds between precast concrete walls and concrete foundations.
D. Main windforce-resisting systems: Precast concrete shear walls.
C. Roof diaphragm systems, including connectors, drag struts and boundary elements: Reinforced concrete topping slab composite with double tee for roof diaphragm with diaphragm chord reinforcing.
B. Wall connections to roof diaphragm and framing: Steel framing to precast wall panel.
A. Roof cladding, soffits, and roof framing connection: Roof vapor retarder, insulation system, cover board and membrane. Field weld deck attachment to steel beams. See item "B" for beam connection to walls.
5. Description of Wind Force-Resisting components subject to Special Inspection of Wind Resistance:
SEE SPECIAL INSPECTION
CHARTS THIS SHEET
4. Description of main Wind Force-Resisting System subject to Special Inspection for Wind Resistance:
PRECAST SHEAR WALLS
3. Statement for Special Inspection for Wind Resistance Required (Y/N): Y
2. Wind Exposure Category: C
1. Nominal Design Wind Speed, Vasd = 115
Quality Assurance Plan for Wind Requirements:
2. Statement of Special Inspections for Seismic Resistance required (Y/N): N
1. Seismic Design Category: B
Quality Assurance for Seismic Resistance:
QUALITY ASSURANCE PLAN
EDI-EIFS EIFS Third Party Inspector Exterior Design Institute (EDI) Certification