Alton Schematic Floor Plan_07-22-26 (1).pdf

PDF 1 MB Posted

Attached to
Construction Manager at Risk (CMaR) Alton Maintenance Garage complex
Solicitation number
645-RFP-3022-2027
Issued by
Taylor County, Alburnett City, Iowa

About this file

This is a schematic floor plan document for the Alton Maintenance Facility prepared by the Iowa Department of Transportation (IDOT). The facility is a single-story structure measuring 238 feet 8 inches in overall length and 90 feet in overall width, designed to support maintenance operations for the department. The facility includes 112 numbered rooms and areas organized into administrative, operational, and storage zones. Key operational spaces include a mechanic's bay, wash bay, welding area, storage bays, utility rooms, locker rooms, restrooms, break/training room, offices, and parts storage. The plan also depicts multiple brine storage tanks (nine 9,500-gallon units and four 5,000-gallon reclaim tanks, with additional future reclaim capacity), an oil disposal area, and mechanical/electrical support spaces. The building incorporates fire-treated wood framing, CMU walls with square corners, tempered/safety glazing, and exposed concrete flooring in designated areas with control joints and sealant. Interior finishes are specified to meet 2024 IBC Chapter 8 requirements for the assigned occupancies and construction type.

The schematic plan establishes the architectural baseline for the Alton Maintenance Garage complex project identified in the concurrent Construction Manager at Risk (CMaR) RFP 645-RFP-3022-2027. The floor plan references are established at a main ground floor slab elevation of 0'-0" (equivalent to civil engineering elevation 1,057.50) and are dated July 22, 2026. All plan modifications, discrepancies between drawings and field conditions, and dimension conflicts must be reported to and approved by the IDOT Architectural Services Project Manager prior to work performance. The document emphasizes that written dimensions govern partition locations and prohibits scaling from the drawings. Interior accessibility requirements for restrooms and other spaces must be verified against detailed restroom floor plans and interior elevations. Knox box installation near the main entrance and interior bollards at all overhead doors are specified safety requirements.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

STORAGE BAYS

WOMEN'S RR

U T

IL

IT

Y R

O O

M

BREAK/TRAIN.

ROOM

CORR

VEST

LOCKER ROOM

OFFICE

SUPPLY

STORAGE

COMM CLOSET

W2

W2

A112

A1126

AED

(O

V E

R A

LL

B

U

IL

D

IN

G

238' - 8" (OVERALL BUILDING)

127' - 4"

30' - 0"

30' - 0"

3' - 4" 2' - 4"

3' - 4" 2' - 4"

3' - 4"

10' - 0"10' - 0"10' - 0"

4' - 0"16' - 0"4' - 0"16' - 0"4' - 0"

4' - 0"

4' - 0"

2' - 0"

4' - 0"

1' - 8"

4' - 0" 16' - 0" 8' - 0"16' - 0" 4' - 0"16' - 0"4' - 0"

4' - 8"6

4' - 0" 6' - 0"

2' - 4"

2' - 4"

AA

BB

MEN'S RR

16' - 0" 8' - 0"16' - 0"

E Q

E

Q

E Q

E

Q

E Q

E

Q

E Q

E Q

6' - 0"

1' - 8"

6' - 0" 6' - 8" 4' - 8" 7' - 8"

MECHANIC'S BAY

WASH BAY

W E

LD

IN

G

A R

E A

9500 GAL

BRINE

9500 GAL

BRINE

9500 GAL

BRINE

9500 GAL

BRINE

9500 GAL

BRINE

9500 GAL

BRINE

9500 GAL

BRINE

FUTURE

5000 GAL

RECLAIM

5000 GAL

RECLAIM

BRINE

OIL

DISPOSAL

5000 GAL

RECLAIM

5000 GAL

RECLAIM

24' - 0" 10' - 0" 16' - 0" 29' - 4" 22' - 4" 20' - 0" 20' - 0" 20' - 0" 20' - 0" 25' - 0" 30' - 0"

4' - 0" 16' - 0" 7' - 8" 16' - 0" 16' - 4" 16' - 0" 8' - 8" 16' - 0" 4' - 0" 16' - 0" 4' - 0" 16' - 0" 30' - 0"

10' - 0" 10' - 0" 10' - 0"6' - 4" 4' - 8" 3' - 4" 2' - 0"

4' - 0"16' - 0"4' - 0"8' - 8" 16' - 0"16' - 0"

10' - 0"10' - 0"10' - 0"10' - 0"

16' - 0"4' - 0"7' - 6"17' - 4" 40' - 0"

FUTURE

5000 GAL

RECLAIM

UTILITY ROOM

MECHANIC'S

OFFICE

PARTS

17' - 0" 13' - 0"29' - 4"16' - 0"34' - 0" 3

20' - 8" 6' - 0"

GENERAL PLAN NOTES

1. DISCREPANCIES BETWEEN THESE DOCUMENTS AND THE ACTUAL FIELD CONDITIONS

SHALL BE BROUGHT TO THE ATTENTION OF THE IDOT ARCHITECTURAL SERVICES BEFORE

PROCEEDING WITH WORK.

2. REVIEW DOCUMENTS AND VERIFY DIMENSIONS AND FIELD CONDITIONS. CONFLICTS OR

OMISSIONS, ETC. SHALL BE IMMEDIATELY REPORTED TO IDOT ARCHITECTURAL

SERVICES FOR CLARIFICATION PRIOR THE PERFORMANCE OF WORK IN QUESTION.

3. DO NOT SCALE OFF OF DRAWINGS. WRITTEN DIMENSIONS GOVERN PARTITION

LOCATIONS. IN CASE OF CONFLICTS IN DIMENSIONS AND OR APPEARANCE CORRELATION

WITH PLANS NOTIFY IDOT ARCHITECTURAL SERVICES.

4. CHANGES TO THE PLANS, DETAILS, INSTALLATION, EQUIPMENT ETC ARE ONLY GRANTED

BY IDOT ARCHITECTURAL SERVICES PROJECT MANAGER..

5. MATERIALS AND USES IN THE BUILDING WILL BE COMPATIBLE WITH THE ASSIGNED

OCCUPANCIES AND CONSTRUCTION TYPE. INTERIOR FINISHES TO MEET IBC CHAPTER 8

REQUIREMENTS. TEMPERED/SAFETY GLAZING TO BE PROVIDED AS INDICATE ON PLANS TO

MEET 2024 IBC 2406.

6. “TYP” OR “TYPICAL” MEANS THAT THE CONDITION IS REPRESENTATIVE FOR SIMILAR

CONDITIONS THROUGHOUT, UNLESS NOTED OTHERWISE.

7. ALL ROUGH FRAMING/BLOCKING WHERE SHOWN IS TO BE FIRE TREATED WOOD.

8. SEE FLOOR PLANS FOR WALL TYPE LOCATIONS. WALL TYPE INDICATORS ARE FOR

CLARIFICATION WHEN IT IS GRAPHICALLY DIFFICULT TO SHOW ON PLAN. NOT ALL WALLS

ARE INDICATED. VERIFY WITH IDOT ARCHITECTURAL SERVICES FOR CLARIFICATION.

IMPORTANT NOTE:

1. ARCHITECTURAL DRAWINGS UTILIZED THE MAIN GROUND

FLOOR SLAB LEVEL ELEVATION AT 0'-0". THIS EQUATES

TO THE CIVIL ENGINEERING FLOOR PLAN SLAB ELEVATION

OF 1057.50.

DO NOT SCALE OFF OF DRAWINGS. WRITTEN DIMENSION GOVERN

PARTITION LOCATION. IN CASE OF CONFLICTS IN DIMENSIONS

AND/OR APPEARANCE CORRELATION WITH PLANS, NOTIFY DOT

ARCHITECTURAL SERVICES.

CHANGES TO THE PLAN, DETAILS, INSTALLATIONS, EQUIPMENT

ETC. ARE ONLY GRANTED BY IDOT ARCHITECTURAL SERVICES

PROJECT MANAGER.

9. PROVIDE BLOCKING AND/OR PLYWOOD PANELS AS REQUIRED FOR ALL WALL

MOUNTED CASEWORK, SHELVING, MONITORS/DISPLAYS, MARKER BOARDS,

BULLETIN BOARDS OR OTHER SIMILAR EQUIPMENT.

10. PROVIDE AND INSTALL “KNOX” BOX NEAR MAIN ENTRANCE. VERIFY FINAL

LOCATION.

11. SEAL ALL PENETRATIONS THROUGH & INTO WALLS. AT ALL OFFICES AND

CONFERENCE ROOMS WALLS ARE SOUND RATED ASSEMBLIES, PROVIDE

ACOUSTICAL SEALANT.

12. ALL FLOOR MATERIAL CHANGES SHALL OCCUR AT CENTER OF DOOR

LEAF/THRESHOLD.

13. SEE STRUCTURAL DRAWINGS FOR INTERIOR CMU WALL LINTELS.

14. SEE RESTROOM FLOOR PLANS AND INTERIOR ELEVATIONS FOR FIXTURE

PLACEMENTS TO MEET ACCESSIBILITY REQUIREMENTS.

15. ALL CMU IS TO BE SQUARE CORNERS, PAINT.

16. SEE STRUCTURAL DRAWINGS FOR FLOOR SLAB CONTROL JOINT AND

EXPANSION JOINT LOCATIONS. ALL SAWCUT AND EXPANSION JOINTS AT ROOMS

SCHEDULE FOR EXPOSED CONCRETE SHALL HAVE JOINT SEALANT. VERIFY COLOR.

17. FURNISH AND INSTALL (2) EACH 4’ X 8’ X ¾” FIRE TREATED PLYWOOD PANEL AT

TWO WALLS AT COMMUNICATION ROOM.

18. INTERIOR BOLLARDS ARE REQUIRED AT ALL OVERHEAD DOORS. SEE BOLLARD

DETAILS.

19. "EJ" REPRESENTS SEALANT OVER EXPANSION JOINT MATERIAL AT FLOOR SLAB,

SIDEWALK OR PAVING.

20. FLOOR PLAN WALL DIMENSIONS SHOWN ARE TYPICALLY TO THE FACE OF THE

CMU OR PRECAST WALL.

21. DASHED LINES INDICATE CRANE RAILS AND BRIDGE BEAM ABOVE, SEE

STRUCTURAL DRAWINGS

22. DIAGONAL LINES SHOWN ON THE FLOOR PLAN INDICATE A VALLEY BETWEEN

SLOPING FLOOR PLANES AS SHOWN ON SHEET A101. THEY ARE NOT SAWCUT

CONTROL JOINTS FILLED WITH SEALANT OR COLD JOINTS . SEE STRUCTURAL

PLANS FOR CONTROL JOINT LOCATIONS.

1/8" = 1'-0"A102

1 FIRST FLOOR PLAN

SHEET

DATE:

R E

V

IS

IO

N

S

COUNTY: DISTRICT:

PROJECT NUMBER:

Resources & Acquisitions Bureau 800 Lincoln Way Ames, Iowa 50010

(515) 239-1299

/2

2/

4:

5:

P M

D

A

L T

O N

M A

IN

T

E N

A N

C E

F A

C

IL

IT

Y

F

IR

S T

F L

O O

R P

L A

N

23 JUNE 2026