J.02 Attachment 02 - Drawing [99 Pages].pdf

PDF 24 MB Posted

Attached to
(PROJ: 573-19-616) BB Correct Electrical Deficiencies (3-Year Test) Federal contract opportunity
Solicitation number
36C24823R0042
Issued by
Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 8

About this file

This solicitation is for electrical deficiency corrective work at a Department of Veterans Affairs medical facility. The solicitation seeks proposals to correct electrical deficiencies through a three-year test contract at the Veterans Affairs Medical Center in Building 1. A site visit is scheduled for November 9th where attendees will park in a garage and meet in Conference Room EB59G-1 in the basement of the main building. Proposals for the work are due by November 28th and the work will be performed under the oversight of the Veterans Health Administration within Veterans Integrated Service Network 8.

View the file

Other files for this federal contract opportunity

Show all 11

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

EXTERIOR ELEVATION

INTERIOR ELEVATION

SECTION/DETAIL NUMBER

DRAWING NUMBER

EQUIPMENT TAG

COLUMN GRID

NOTE

WINDOW OPENING

DOOR OPENING

ROOM NAME

ROOM NUMBER

WALL TYPE

SEE SHEET A001

CEILING HEIGHT

FINISH DESIGNATION

X

10'-8"

X

X

XX.X-X

XX

X

1/A101

X

A101

XX

TOILET ACCESSORY TAGX SIGNAGE TAG

T-3 T- 1A

T-7 T-

T-9

T-10

T-1

BLDG. 12

CLC

T-5

T-11 T-2

MEP

T-4

T-6

B30

G02

G03

G01

G1

WATER TANK

PUMP

HOUSE

B01

ACA

ST

A

T E O F F L O R

ID

A

RE

G

IS

T E R E D A R C H

IT

EC

T

ROGE

R A R E P

ST

IEN

A R

VA Project No.

RDC/JPA Project No.

Department of Veterans Affairs Medical Center

ABOVE GROUP

ENGINEERING

70 BIRCH ALLEY, SUITE 250

BEAVERCREEK OHIO, 45440

937.795.4440

ARCHITECTURE PLANNING INTERIOR DESIGN

524 FERNWOOD AVENUE

ALTAMONTE SPRINGS, FLORIDA 32701

407.830.6522 P

937.461.0260 F

RDC / JOHN POE ARCHITECTS

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

Office of Construction and Facilities Management

/1

/2

:0

:5

P

M

Correct Electrical Deficiencies (3-Year Test)

12..2020

COVER SHEET

G001

MDMD

573-19-616

Gainesville, Florida

Correct Electrical Deficiencies (3-Year Test)

1601 SW Archer Rd Gainesville, FL 32608 PROJECT #: 573-19-616

100% CONSTRUCTION

DOCUMENTS

19019.00

G001 COVER SHEET

A101 B25 BATTERY CLOSET

S-101 STRUCTURAL SECTIONS & DETAILS MEP BUILDING ROOF

S-201 STRUCTURAL SECTIONS & DETAILS MEP BUILDING ROOF

M-000 MECHANICAL LEGENDS, SYMBOLS, & NOTES

MD101 MECHANICAL DEMO FLOOR/ROOF PLAN – BLDG. 25

MD102 MECHANICAL DEMO FLOOR/ROOF PLAN – MEP BLDG.

MD103 MECHANICAL DEMO FLOOR PLAN – ACA BLDG.

MH101 MECHANICAL NEW WORK FLOOR/ROOF PLAN – BLDG. 25

MH102 MECHANICAL NEW WORK FLOOR/ROOF PLAN – MEP BLDG.

MH103 MECHANICAL NEW WORK FLOOR PLAN – ACA BLDG.

M-201 MECHANICAL DETAILS

M-202 MECHANICAL DETAILS

M-301 MECHANICAL SCHEDULES

E-001 ELECTRICAL LEGENDS

E-002 ELECTRICAL GENERAL NOTES

E-003 ELECTRICAL SCHEDULES

ED101 ELECTRICAL DEMO FLOOR/ROOF PLAN - BLDG. 25

ED102 ELECTRICAL DEMO FLOOR/ROOF PLAN – MEP BLDG.

EP101 ELECTRICAL NEW WORK FLOOR/ROOF PLAN – BLDG. 25

EP102 ELECTRICAL NEW WORK FLOOR/ROOF PLAN – MEP BLDG.

EP103 ELECTRICAL NEW WORK FLOOR PLAN – ACA BLDG.

EP104 ELECTRICAL NEW WORK FLOOR PLAN – BED TOWER

EP105 ELECTRICAL NEW WORK FLOOR PLAN – BUILDING 1

GENERAL CONSTRUCTION NOTES

7. CONTRACTOR IS RESPONSIBLE TO VERIFY SIZES OF ALL EQUIPMENT, ETC. TO

BE INSTALLED AS PART OF THIS PROJECT, AND WHERE NECESSARY, MAKE

SPECIAL PROVISIONS TO INSTALL EQUIPMENT THAT IS TOO LARGE TO FIT

THROUGH FINISHED OPENINGS.

8. CONTRACTOR SHALL PROVIDE WOOD BLOCKING AT TOILET ACCESSORIES,

HAND RAILS, BUMPER RAILS, SHELVING, CASEWORK, MOUNTING BRACKETS

AND OTHER WALL MOUNTED ITEMS, AS INDICATED IN THE CONTRACT

DOCUMENTS AND AS RECOMMENDED BY PRODUCT MANUFACTURERS. ALL

WOOD BLOCKING SHALL BE FIRE RETARDANT TREATED.

9. ALL EXPOSED NEW WORK IS TO RECEIVE NEW FINISHES UNLESS

SPECIFICALLY NOTED OTHERWISE. iF NO FINISH IS INDICATED AT A

PARTICULAR SURFACE, CONTRACTOR SHALL PROVIDE FINISH(S) AS

INDICATED AT SIMILAR CONDITIONS.

10. CONTRACTOR SHALL PROVIDE COMPLETE AND FULLY OPERATIONAL

SYSTEMS WHICH COMPLY WITH STATED CODES AND REGULATIONS. WHERE

THE OMISSION OF A PART OR ELEMENT OF A SYSTEM WOULD RESULT IN THE

NON-OPERATION, OR INCORRECT OPERATION OF A SYSTEM, CONTRACTOR

SHALL INCLUDE SAID PART OR ELEMENT AS PART OF THE WORK.

11. ALL PENETRATIONS THROUGH NEW AND/OR EXISTING SMOKE OR FIRE RATED

WALLS SHALL BE SMOKE/FIRE STOPPED AS REQUIRED BY THE RATING OF

THE WALL.

12. CONTRACTOR TO COMPLY WITH VA CAMPUS COVID-19 REGULATIONS

INCLUDING DAILY SCREENING.

* PLEASE NOTE THAT THE TERM PROJECT ENGINEER REFERS TO THE

CONTRACTING OFFICER'S REPRESENTATIVE (C.O.R.).

1. ALL WORK SHALL COMPLY WITH THE LATEST NFPA 101 LIFE SAFETY CODE,

INTERNATIONAL BUILDING CODE, AND OTHER COES AS IDENTIFIED IN VHA

PROGRAM GUIDE PG-18-3, TOPIC 01, CODES, STANDARDS AND EXECUTIVE

ORDERS WHICH CAN BE FOUND ON THE DEPARTMENT OF VETERAN AFFAIRS,

TECHNICAL INFORMATION LIBRRARY WEBSITE.

2. ALL WORK SHALL COMPLY WITH REQUIREMENTS OF THE LATEST

ARCHITECTURAL BARRIERS ACT ACCESSIBILITY STANDARD (ABAAS) AND

DEPARTMENT OF VETERANS AFFAIRS BARRIER FREE DESIGN GUIDE PG-18-13

WHICH CAN BE FOUND ON THE DEPARTMENT OF VETERANS AFFAIRS

TECHNICAL INFORMATION LIBRARY WEBSITE.

3. CONTRACTOR IS RESPONSIBLE TO VISIT THE SITE, EXAMINE AND ACCEPT

EXISTING CONDITIONS PRIOR TO BIDDING. SITE VISITS TO BE COORDINATED

WITH THE CONTRACTING OFFICER'S REPRESENTATIVE.

4. CONTRACTOR IS RESPONSIBLE TO REPAIR AND/OR REFINISH, TO MATCH

ADJACENT EXISTING SURFACES, ANY EXISTING MATERIALS TO REMAIN THAT

ARE DAMAGED DURING THE COURSE OF DEMOLITION OR NEW WORK.

5. WHERE REMOVAL OF EXISTING WORK IS REQUIRED FOR INSTALLATION OF

NEW WORK, CONTRACTOR SHALL REPAIR EXISTING CONSTRUCTION TO

REMAIN OR PROVIDE NEW CONSTRUCTION TO MATCH EXISTING ADJACENT

SURFACES TO REMAIN.

6. CONTRACTOR IS RESPONSIBLE TO FIELD VERIFY ALL CONDITIONS AND

DIMENSIONS PRIOR TO ORDERING, FABRICATING OR INSTALLING NEW

MATERIALS.

DRAWING INDEX

GRAPHIC SYMBOLS

VICINITY MAP

Revisions Date

07.13.2021

305 EAST DR, SUITE H,

MELBOURNE, FLORIDA 32904

321.345.9026

10'-0"

1'-0" 1'-0"

B25-2

S1.0

Switchgear

B25-1

Battery Closet

B25-2

S1.0

4 7/8"

9.219.21

9.02

9.80

7.82

7.82

STRUCTURE ABOVE

FIN. CEILING

FLOOR SLAB

SEE SCHED.

S E

E S

C H

E D

U L E

F

2"

SEE

SCHED. 2"

S E

E S

C H

E D

U L E

SEE PLAN

1/2" 1/2"

H1

J1

8.02

9.21

9.80

8.02

9.09

9.21

9.80

9.08

7.82

7.82 1/2" 1/2"

ST

A

T E O F F L O R

ID

A

RE

G

IS

T E R E D A R C H

IT

EC

T

ROGE

R A R E P

ST

IEN

A R

VA Project No.

RDC/JPA Project No.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

Office of Construction and Facilities Management

/1

/2

:0

:5

P

M

Correct Electrical Deficiencies (3-Year Test)

12..2020

B25 BATTERY CLOSET

A101

MDMD

573-19-616

Gainesville, Florida

100% CONSTRUCTION

DOCUMENTS

19019.00

Scale: 1/4" = 1'-0"1 B25 - Floor Plan

Scale: 1" = 1'-0"

Wall Types

A. All dimensions are taken to face of gypsum wallboard or unit masonry.

B. Edge of all door jambs at hinge side not otherwise indicated are to be 6" from the face of intersecting walls. Edge of all door jambs at strike side not otherwise located are to be 18" minimum from the face of intersecting walls.

C. All wood blocking to be fire retardent treated.

D. All partitions shall be type 'S1.0' unless noted otherwise.

7.82 Continuous acoustic sealant @ non-rated walls / fire-rated sealant @ rated walls each side.

8.02 Hollow metal frame.

9.02 3 5/8" non-structural metal framing @ 16" o.c.

9.08 Metal framing box header.

9.09 Double metal framing at jambs, typ.

9.21 5/8" Type X gypsum board.

9.80 Acoustic insulation

NOTES

GENERAL NOTES

DOOR SCHEDULE

DOOR

BETWEEN DOOR DESCRIPTION FRAME DESCRIPTION

FIRE

RATING

HDWE

SET REMARKSRM RM TYPE MAT'L

SIZE

TYPE MAT'L HEAD JAMB# W H T

ACA ACA EXT. F HM 2 3'-0" 7'-0" 1 3/4" 1 HM EXST. EXST. - 1 Existing HM frame to remain. See Mechanical ACA plan for door location.

B25-2 B25-2 B25-1 F WD 4 2'-3" 7'-0" 1 1/2" 1 HM 1 1 - 2

N.T.S.Scale:

DOOR TYPES

N.T.S.Scale:

H.M. FRAME TYPES

Scale: 1 1/2" = 1'-0"

H.M. FRAME DETAILS

Revisions Date

07.13.2021

20.1 19.1 18.3 18.1 17.6

W.1

U

V

T.1

T

17.1

S

AHU-66

MEP BUILDING ROOF PLAN

SCALE: 3/16" = 1'-0"

A S201

REF: ABOVE GROUP SHEET MH102

VA FORM 08 - 6231

A

B

C

D

E

F

21 4 5 6 7 8 9 10

321 4 5 6 7 8 9 10

VA Project No.

AG Project No.

Project Number

Building

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

U.S. Department of Veterans Affairs

PhaseARCHITECT/ENGINEER OF RECORDCONSULTANT Office of Construction and Facilities Management www.abovegroupinc.com COA/CA Lic. No. 31120

305 East Dr., Suite H, Melbounre, Florida 32904

PH: 321.345.9026

100% CONSTRUCTION

DOCUMENTS

BI

M

- C or re ct E le ct ric al

D ef ic ie nc ie s/

C or re ct E le ct ric al

D ef ic ie nc ie s R

M

EP

FP

.rv t

/1

1/

:1 8:

P

M

573-19-616

CORRECT ELECTRICAL

DEFICIENCIES

GAINESVILLE VA

0119039

Revisions Date

STRUCTURAL SECTIONS & DETAILS

MEP BUILDING ROOF

07/13/2021 AJN RP

S-101

SHEET LIST

Sheet Number Sheet Name

S-101 STRUCTURAL NOTES & MEP BLDG ROOF PLAN

S-201 STRUCTURAL SECTIONS & DETAILS MEB BLDG ROOF

GENERAL

1. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND EXISTING CONDITIONS IN THE FIELD AND

NOTIFY THE ENGINEER OF ANY DISCREPANCIES PRIOR TO PROCEEDING WITH FABRICATION AND

CONSTRUCTION.

2. ALL STRUCTURAL SHEETS SHALL BE USED IN CONJUNCTION WITH THE CIVIL, MECHANICAL, ELECTRICAL, AND PROJECT SPECIFICATIONS.

3. GOVERNING BUILDING CODES::

a. 2017 FLORIDA BUILDING CODE AND ALL OTHER APPLICABLE LOCAL CODES

b. ASCE 7-16 MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES

4. DESIGN WIND LOADS ARE IN ACCORDANCE WITH ASCE 7-16 USING THE FOLLOWING CRITERIA:

a. RISK CATEGORY = III

b. ULTIMATE WIND SPEED, V ULT = 135 MPH

c. NOMINAL WIND SPEED, V ASD = 105 MPH

d. IMPORTANCE FACTOR = 1.15

e. EXPOSURE CATEGORY = B

f. INTERNAL PRESSURE COEFF. = +/-0.18 (ENCLOSED)

5. ALL DETAILS APPLY TO SIMILAR SITUATIONS UNLESS SPECIFICALLY NOTED OTHERWISE ELSEWHERE.

POST-INSTALLED AND ADHESIVE ANCHORS

1. ANCHORS AND ADHESIVE ANCHORING SYSTEMS MUST BE TESTED AND APPROVED USING ICC

EVALUATION SERVICE ACCEPTANCE CRITERIA,, INCLUDING ICC-ES AC193 "MECHANICAL ANCHORS IN CONCRETE ELEMENTS" OR ICC-ES AC308 'POST-INSTALLED ADHESIVE ANCHORS IN CONCRETE

ELEMENTS". CONCRETE SHALL BE CONSIDERED CRACKED. SUBMIT MANUFACTURER'S DATA AND

EVALUATION REPORT (ESR) FOR PROPOSED ANCHORS.

2. MECHANICAL ANCHORS TO CONCRETE SHALL BE AS SHOWN IN THE STRUCTURAL DETAILS, UNLESS

NOTED OTHERWISE. USE ONE OF THE FOLLOWING:

a. HILTI KWIK BOLT TZ EXPANSION ANCHORS

b. HILTI HDA UNDERCUT ANCHORS

c. POWERS POWER-STUD+ SD2 WEDGE EXPANSION ANCHORS

d. SIMPSON STRONG-BOLT 2 WEDGE ANCHORS

3. ADHESIVE ANCHORING OF RODS AND REINFORCING BAR TO CONCRETE SHALL BE AS SHOWN IN

THE STRUCTURAL DETAILS, UNLESS NOTED OTHERWISE. PROVIDE STANDARD HAS-E RODS AND

USE ONE OF THE FOLLOWING:

a. HILTI HY-200 HYBRID ADHESIVE ANCHORING SYSTEM

b. HILTI RE-500-SD EPOXY ADHESIVE ANCHORING SYSTEM

c. POWERS PE-1000+ EPOXY ADHESIVE ANCHORING SYSTEM

d. SIMPSON SET-XP EPOXY ANCHORING ADHESIVE

4. MINIMUM EMBEDMENT, UNLESS OTHERWISE NOTED, SHALL BE AS FOLLOWS:

a. 1/2" DIA OR #4 REBAR = 4 1/2" EMBED

b. 5/8" DIA OR #5 REBAR = 5 5/8" EMBED

c. 3/4" DIA OR #6 REBAR = 6 3/4" EMBED

d. 1" DIA OR #8 REBAR = 9" EMBED

5. ALL ANCHORS AND RELATED HARDWARE SHALL BE GALVANIZED OR STAINLESS STEEL.

AHU-66 ROOF SECTIONA

S-201 SCALE: 3/4" = 1'-0"

RTU-1

RTU-1 ROOF ATTACHMENT

SEE SECTION 1/S-201

AHU-66 ROOF UNIT ATTACHMENTB

S-201 SCALE: 1 1/2" = 1'-0"

EXISTING INSULATION

EXISTING ROOF

MEMBRANE

NEW 4x4 CANT STRIP

NEW RIGID INSULATION

#14x3

4" SELF DRILLING

SCREWS @ 24" O.C.

NEW 24 GA FLASHING

EQUIPMENT

BASE PANEL

RTU-1 EQUIPMENT

SEE MECHANICAL DRAWINGS

EXISTING CAST IN

PLACE ROOF SLAB

16 GA GALVINIZED

STRAP 18" O.C. MAX

#12 SELF DRILLING SCREWS S.S.

ADHESIVE ANCHORS

2"Ø STAINLESS STEEL

TOTAL 8 BOLTS REQUIRED

NOTE:

ALL ANCHORS SHALL BE LOCATED OVER

CIP RIBS AS SHOWN

#12 SELF DRILLING SCREWS S.S.

VA FORM 08 - 6231

A

B

C

D

E

F

21 4 5 6 7 8 9 10

321 4 5 6 7 8 9 10

VA Project No.

AG Project No.

Project Number

Building

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

U.S. Department of Veterans Affairs

PhaseARCHITECT/ENGINEER OF RECORDCONSULTANT Office of Construction and Facilities Management www.abovegroupinc.com COA/CA Lic. No. 31120

305 East Dr., Suite H, Melbounre, Florida 32904

PH: 321.345.9026

100% CONSTRUCTION

DOCUMENTS

BI

M

- C or re ct E le ct ric al

D ef ic ie nc ie s/

C or re ct E le ct ric al

D ef ic ie nc ie s R

M

EP

FP

.rv t

/1

1/

:1 8:

P

M

573-19-616

CORRECT ELECTRICAL

DEFICIENCIES

GAINESVILLE VA

0119039

Revisions Date

STRUCTURAL SECTIONS & DETAILS

MEP BUILDING ROOF

07/13/2021 AJN RP

S-101

SHEET LIST

Sheet Number Sheet Name

S-101 STRUCTURAL NOTES & MEP BLDG ROOF PLAN

S-201 STRUCTURAL SECTIONS & DETAILS MEB BLDG ROOF

DUCTWORK SYMBOLS

SYMBOL DESCRIPTION ABBR. DESCRIPTION

A/E ARCHITECT / ENGINEER

AHU AIR-HANDLING UNIT

AMP AMPERGE

BTUH BRITISH THERMAL UNIT PER HOUR

CD CONDENSATE

CD CONSTRUCTION DOCUMENTS

CFM CUBIC FEET PER MINUTE

CU CONDENSING UNIT

DD DESIGN DOCUMENTS

DEG DEGREE

EA EXHAUST AIR

EAT ENTERING AIR TEMPERATURE

ECC ENGINEERING CONTROL CENTER

EER ENERGY EFFICIENCY RATIO

EF EXHAUST FAN

ENT ENTERING

(E) EXISTING

F FAHRENHEIT

FLA FULL LOAD AMPS

HOA HAND/OFF/AUTOMATIC

IN WG INCH WATER GAUGE

kW KILOWATT

LAT LEAVING AIR TEMPERATURE

MIN MINIMUM

NC NOISE CRITERIA

NOM NOMINAL

NTS NOT TO SCALE

OA OUTSIDE AIR

RA RETURN AIR

RLA RUN LOAD AMPERE

DN

DN

UP

UP

SUPPLY DUCT (UP & DOWN)

EXHAUST DUCT (UP & DOWN)

SUPPLY TOP REGISTER OR GRILLE (WALL

TYPE)

EXHAUST OR RETURN CEILING REGISTER OR

GRILLE

EXHAUST OR RETURN BOTTOM REGISTER OR

GRILLE (WALL TYPE)

EXHAUST OR RETURN REGISTER OR TOP

GRILLE (WALL TYPE)

VANED ELBOW & AIR SPLIT TYPE DUCT TAKE-

OFF

D

INCLINED RISE, IN DIRECTION OF AIR FLOW

INCLINED DROP, IN DIRECTION OF AIR FLOW

R

DNUP RETURN DUCT (UP & DOWN)

FC

10x8

FLEXIBLE CONNECTION,

EQUIPMENT, VIBRATION, OR SEISMIC

VANED ELBOW (PROVIDE ALL SQUARE OR

RECTANGULAR ELBOWS WITH VANES EVEN IF

SYMBOL IS MISSING)

VANED ELBOW (SHORT RADIUS)

STANDARD RADIUS ELBOW (LONG RADIUS)

NEW DUCT (INSIDE DIMENSIONS: WIDTH x

DEPTH)

EXISTING DUCT TO REMAIN

VD

FLEXIBLE DUCTWORK (INSULATED)

MANUAL VOLUME DAMPER

SUPPLY

RETURN45°

STANDARD BRANCH SUPPLY

OR RETURN, NO SPLITTER(45° TAP)

45°

MOTORIZED DAMPER

M

SYMBOL DESCRIPTION

PIPING SYMBOLS

CONDENSATECD

SIDE CONNECTION

BOTTOM CONNECTION, 45° OR 90°

TOP CONNECTION, 45° OR 90°

RISE OR DROP IN PIPE

CAPPED OUTLET

PIPE UP

PIPE DOWN

ABBREVIATIONS

WELDED STAINLESS STEEL DUCTWORK

SYMBOL DESCRIPTION

CONTROL SYMBOLS

ECC

IT CURRENT TRANSMITTER

INTEGRATE CONTROL POINT ON REMOTE GRAPHICS

WORKSTATION AT ENERGY CONTROL CENTER

T THERMOSTAT

1. CONNECTION TO EQUIPMENT SHALL BE VERIFIED WITH MANUFACTURER'S CERTIFIED DRAWINGS.

TRANSITIONS TO ALL EQUIPMENT SHALL BE VERIFIED AND PROVIDED FOR EQUIPMENT FURNISHED.

2. DIMENSIONS SHALL BE FIELD-VERIFIED AND COORDINATED PRIOR TO PROCUREMENT OR FABRICATION.

COORDINATE THE WORK WITH OTHER TRADES INVOLVED. FIELD MODIFICATIONS SUCH AS OFFSETS IN

PIPING OR DUCTWORK (INCLUDING DIVIDED DUCTWORK) NEEDED DUE TO OBSTRUCTIONS OR

INTERFERENCES SHALL BE PROVIDED AT NO ADDITIONAL COST.

3. DUCT CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE LATEST EDITION OF THE SMACNA HVAC DUCT

CONSTRUCTION STANDARD.

4. PROVIDE 1.5R ELBOWS IN DUCTWORK AS INDICATED. IF 1.5R ELBOWS DO NOT FIT, PROVIDE 1.0R ELBOWS.

IF 1.0R ELBOWS DO NOT FIT, PROVIDE 90 DEGREE RECTANGULAR DUCT ELBOWS WITH TURNING VANES.

5. DUCT SIZES AND ALL OPENINGS THROUGH BUILDING CONSTRUCTION SHALL SUIT EQUIPMENT FURNISHED.

6. LOCATE THERMOSTATS, TEMPERATURE SENSORS, HUMIDISTATS, AND HUMIDITY SENSORS AT 48" ABOVE FINISHED FLOOR UNLESS NOTED OTHERWISE. COORDINATE LOCATIONS WITH OTHER EQUIPMENT, FURNITURE, AND DOOR SWINGS.

7. ALL EQUIPMENT, DUCTWORK, ETC., SHALL BE SUPPORTED AS DETAILED AND/OR SPECIFIED. PROVIDE

ADDITIONAL SUPPORTS AS REQUIRED TO PROVIDE A VIBRATION-FREE, RIGID INSTALLATION.

8. ALL DUCT SIZES SHOWN ARE INSIDE CLEAR DIMENSIONS.

9. DAMPERS AND INSIDES OF DUCTS VISIBLE THROUGH GRILLES, REGISTERS AND DIFFUSERS SHALL BE

PAINTED FLAT BLACK.

10. REFER TO TYPICAL DETAILS FOR PIPING AND INSTALLATION OF EQUIPMENT.

11. TRAPPED CONDENSATE DRAINS FROM ALL MECHANICAL EQUIPMENT SHALL BE PROVIDED FOR PROPER

DRAINAGE TO SUIT EQUIPMENT FURNISHED.

12. ACCESS PANELS IN DUCTWORK AND CEILINGS SHALL BE PROVIDED WHERE REQUIRED FOR OPERATION, BALANCING OR MAINTENANCE OF ALL MECHANICAL EQUIPMENT.

13. ALL DUCTWORK AND PIPING IS SHOWN SCHEMATICALLY. PROVIDE ALL TRANSITIONS, TURNING VANES, ELBOWS, FITTINGS, ETC., TO ALLOW SMOOTH FLOWS.

14. COORDINATE SIZE REQUIREMENTS OF ALL CONCRETE HOUSEKEEPING PADS UNDER ALL FLOOR-MOUNTED

EQUIPMENT.

15. VERIFY FINISH WITH ARCHITECT PRIOR TO PURCHASING GRILLES, REGISTERS, DIFFUSERS, LOUVERS AND

OTHER AIR DISTRIBUTION DEVICES.

16. PROVIDE FLEXIBLE DUCT CONNECTIONS ON ALL DUCTWORK CONNECTING TO FANS, AIR HANDLING UNITS, AND FAN COIL UNITS.

17. PROVIDE TRANSITIONS AT DIFFUSER NECKS AS REQUIRED TO MATCH SIZES OF FLEX DUCTS TO BE

CONNECTED.

18. SLEEVE AND SEAL ALL PIPING PENETRATIONS THROUGH BUILDING PARTITIONS.

GENERAL NOTES

DRAWING SYMBOLS

BASIC MATERIALS

EXISTING TO BE REMOVED (HEAVY, DASHED)

EXISTING TO REMAIN (THIN, HALFTONED LINE)

NEW (HEAVY, SOLID LINE)

26-SF 3

26-TU-I-I

DETAIL NUMBER DRAWING

DRAWING NUMBER WHERE SHOWN

SECTIONLETTER

TYPICAL UNIT NO.

BUILDING NO. WHERE EQUIPMENT IS LOCATED.

SUPPLY FAN NO. 3 IN BUILDING NO. 26

EQUIPMENT ABBREVIATION (SUPPLY FAN). AN "(E)" SHOWN IN FRONT OF

EQUIPMENT TAGS NOTIFIES THAT EQUIPMENT IS EXISTING

ITEM NUMBER (TERMINAL UNIT NO. 1)

ITEM (TERMINAL UNIT SHOWN)

SERVED BY AIR HANDLER UNIT NO. 1

BUILDING NO. WHERE EQUIPMENT IS LOCATED

H4

H7

A

NUMBER WHERE DRAWN

TT TEMPERATURE TRANSMITTER

UC UNIT CONTROLLER

DUCT SMOKE DETECTOR

VA FORM 08 - 6231

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

321 4 5 6 7 8 9 10

VA Project No.

AG Project No.

Project Number

Building

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

U.S. Department of Veterans Affairs

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT Office of Construction and Facilities Management www.abovegroupinc.com COA/CA Lic. No. 31120

305 East Dr., Suite H, Melbounre, Florida 32904

PH: 321.345.9026

100% CONSTRUCTION

DOCUMENTS

B

IM

/0

C o rr e c t E le c tr ic a l D e fi c ie n c ie s /0

C o rr e c t E le c tr ic a l D e fi c ie n c ie s R

M

E P

F P

.r v t

/1

/2

:2

:2

A

M

573-19-616

KYLE J .DAVIS, P.E.

FL License #84275

MECHANICAL LEGENDS,

SYMBOLS, & NOTES

CORRECT ELECTRICAL

DEFICIENCIES

GAINESVILLE VA

07/13/2021 KJD MRK

M-000

0119039

SHEET LIST

Sheet Number Sheet Name

M-000 MECHANICAL LEGENDS, SYMBOLS, & NOTES

MD101 MECHANICAL DEMO FLOOR/ROOF PLAN - BLDG. 25

MD102 MECHANICAL DEMO FLOOR/ROOF PLAN - MEP BLDG.

MD103 MECHANICAL DEMO FLOOR PLAN - ACA BLDG.

MH101 MECHANICAL NEW WORK FLOOR/ROOF PLAN - BLDG. 25

MH102 MECHANICAL NEW WORK FLOOR/ROOF PLAN - MEP BLDG.

MH103 MECHANICAL NEW WORK FLOOR PLAN - ACA BLDG.

M-201 MECHANICAL DETAILS

M-202 MECHANICAL DETAILS

M-301 MECHANICAL SCHEDULES

P R

O F

E S

S

I O NA L

E N G

I N

E E

R

L I CENSE

F L O R I DA

STATE

No. 84275

SI

VAD.JELYK

MD101

MD101

KEY PLAN

SCOPE OF

WORK

(E)EF-11

B25 - FIRST FLOOR

47' - 9"

BLDG 25 ROOF

63' - 5"

2 2

B25 - FIRST FLOOR

47' - 9"

BLDG 25 ROOF

63' - 5"

2 3

VA FORM 08 - 6231

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

321 4 5 6 7 8 9 10

VA Project No.

AG Project No.

Project Number

Building

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

U.S. Department of Veterans Affairs

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT Office of Construction and Facilities Management www.abovegroupinc.com COA/CA Lic. No. 31120

305 East Dr., Suite H, Melbounre, Florida 32904

PH: 321.345.9026

100% CONSTRUCTION

DOCUMENTS 25

NOT SPRINKLERED

B

IM

/0

C o rr e c t E le c tr ic a l D e fi c ie n c ie s /0

C o rr e c t E le c tr ic a l D e fi c ie n c ie s R

M

E P

F P

.r v t

/1

/2

:2

:3

A

M

573-19-616

KYLE J .DAVIS, P.E.

FL License #84275

MECHANICAL DEMO FLOOR/ROOF

PLAN - BLDG. 25

CORRECT ELECTRICAL

DEFICIENCIES

GAINESVILLE VA

07/13/2021 KJD MRK

MD101

0119039

1/4" = 1'-0"MD101

1 MECHANICAL DEMO FLOOR PLAN - BLDG. 25

0 2' 4' 8' 12'

1/4" = 1'-0" N

CODED NOTES:

1. DEMOLISH EXISTING EXHAUST FAN, MESH SCREEN, AND DAMPER. DEMOLISH ASSOCIATED

ACCESSORIES AND CONTROLS. CAP EXISTING ROOF CURB UNTIL NEW FAN INSTALLATION.

2. PROVIDE SHEET METAL PANEL AND BLANK OFF EXISTING LOUVER. FIELD VERIFY EXACT LOUVER

DIMENSIONS FOR BLANK OFF PANEL.

3. EXISTING LOUVER ABOVE DOOR SHALL REMAIN.

XX

1/4" = 1'-0"MD101

4 MECHANICAL DEMO ROOF PLAN - BLDG. 25

1/4" = 1'-0"MD101

2 BLDG. 25 SECTION 1

1/4" = 1'-0"MD101

3 BLDG. 25 SECTION 2

Revisions Date

P R

O F

E S

S

I O NA L

E N G

I N

E E

R

L I CENSE

F L O R I DA

STATE

No. 84275

SI

KEY PLAN

SCOPE OF WORK

20.1 19.1 18.3 18.1 17.6

W.1

U

V

T.1

T

17.1

S

(E)EF-21

(E)EF-13

MD102

20.1 19.1 18.3 18.1 17.6

W.1

U

V

T.1

T

17.1

S

MD102

7 7

VA FORM 08 - 6231

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

321 4 5 6 7 8 9 10

VA Project No.

AG Project No.

Project Number

Building

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

FULLY SPRINKLERED

U.S. Department of Veterans Affairs

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT Office of Construction and Facilities Management www.abovegroupinc.com COA/CA Lic. No. 31120

305 East Dr., Suite H, Melbounre, Florida 32904

PH: 321.345.9026

100% CONSTRUCTION

DOCUMENTS MEP

B

IM

/0

C o rr e c t E le c tr ic a l D e fi c ie n c ie s /0

C o rr e c t E le c tr ic a l D e fi c ie n c ie s R

M

E P

F P

.r v t

/1

/2

:2

:4

A

M

573-19-616

KYLE J .DAVIS, P.E.

FL License #84275

MECHANICAL DEMO FLOOR/ROOF

PLAN - MEP BLDG.

CORRECT ELECTRICAL

DEFICIENCIES

GAINESVILLE VA

07/13/2021 KJD MRK

MD102

0119039

0 2' 4' 8' 12'

1/4" = 1'-0" N

CODED NOTES:

1. DEMOLISH EXISTING EXHAUST FAN AND DAMPER. DEMOLISH ASSOCIATED ACCESSORIES AND

CONTROLS. CAP EXISTING ROOF CURB - REFER TO DETAIL.

2. PROVIDE SHEET METAL PANEL AND BLANK OFF EXISTING LOUVER. FIELD VERIFY EXACT LOUVER

DIMENSIONS FOR BLANK OFF PANEL.

3. DEMOLISH EXISTING EXHAUST FAN AND DAMPER. DEMOLISH ASSOCIATED ACCESSORIES AND

CONTROLS. EXISTING ROOF CURB SHALL REMAIN.

4. EXISTING HOOD TO REMAIN.

5. EXISTING TO REMAIN EXHAUST DUCTWORK ROUTED ON ROOF.

6. EXISTING LOUVER TO REMAIN.

7. EXISTING UNIT HEATER TO REMAIN.

XX

1/8" = 1'-0"MD102

3 MECHANICAL DEMO ROOF PLAN - MEP BLDG.

1/8" = 1'-0"MD102

1 MECHANICAL DEMO FLOOR PLAN - MEP BLDG.

N.T.S.MD102

2 MEP BLDG. PHOTO 1

N.T.S.MD102

4 MEP BLDG. PHOTO 2

Revisions Date

P R

O F

E S

S

I O NA L

E N G

I N

E E

R

L I CENSE

F L O R I DA

STATE

No. 84275

SCOPE OF

WORK

33 32 31

K.3

M

M.6

N

MD103

MD103

MD103

MD103

4 4

VA FORM 08 - 6231

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

321 4 5 6 7 8 9 10

VA Project No.

AG Project No.

Project Number

Building

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

FULLY SPRINKLERED

U.S. Department of Veterans Affairs

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT Office of Construction and Facilities Management www.abovegroupinc.com COA/CA Lic. No. 31120

305 East Dr., Suite H, Melbounre, Florida 32904

PH: 321.345.9026

100% CONSTRUCTION

DOCUMENTS ACA

B

IM

/0

C o rr e c t E le c tr ic a l D e fi c ie n c ie s /0

C o rr e c t E le c tr ic a l D e fi c ie n c ie s R

M

E P

F P

.r v t

/1

/2

:2

:4

A

M

573-19-616

KYLE J .DAVIS, P.E.

FL License #84275

MECHANICAL DEMO FLOOR PLAN -

ACA BLDG.

CORRECT ELECTRICAL

DEFICIENCIES

GAINESVILLE VA

07/13/2021 KJD MRK

MD103

0119039

0 2' 4' 8' 12'

1/4" = 1'-0" N

1/4" = 1'-0"MD103

1 MECHANICAL DEMO FLOOR PLAN - ACA BLDG.

CODED NOTES:

1. PROVIDE SHEET METAL PANEL AND BLANK OFF EXISTING LOUVER. FIELD VERIFY EXACT LOUVER

DIMENSIONS FOR BLANK OFF PANEL.

2. PROVIDE SHEET METAL PANEL AND BLANK OFF EXISTING WALL GRILLE. FIELD VERIFY EXACT WALL

GRILLE DIMENSIONS FOR BLANK OFF PANEL.

3. EXISTING UNIT HEATER TO REMAIN.

4. REPLACE EXISTING LOUVERED METAL DOORS AND REPLACE WITH NEW, SOLID, INSULATED,

HOLLOW METAL DOORS. PROVIDE NEW HARDWARE TO MATCH EXISTING.

5. PROVIDE SHEET METAL PANEL AND BLANK OFF EXISTING LOUVER ABOVE DOUBLE DOORS. FIELD

VERIFY EXACT LOUVER DIMENSIONS FOR BLANK OFF PANEL.

XX

N.T.S.MD103

2 ACA BLDG. PHOTO 1

N.T.S.MD103

3 ACA BLDG. PHOTO 2

N.T.S.MD103

4 ACA BLDG. PHOTO 3

N.T.S.MD103

5 ACA BLDG. PHOTO 4

Revisions Date

P R

O F

E S

S

I O NA L

E N G

I N

E E

R

L I CENSE

F L O R I DA

STATE

No. 84275

SCOPE OF

WORK

AHU 67

CU 67

6ø EA

C 825 C 825

28x16 SA

T

C 100

C F

M

100 CFM 6

EXISTING ELECTRICAL GEAR

EXISTING ELECTRICAL GEAR

MH101

EXISTING BATTERIES

NEW BATTERY

STORAGE ROOM

C 825 C 825

2' - 10"

3' - 10"

MH101

24ø SA 22ø SA 18ø SA 14ø SA

EF 181

VA FORM 08 - 6231

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

321 4 5 6 7 8 9 10

VA Project No.

AG Project No.

Project Number

Building

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

U.S. Department of Veterans Affairs

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT Office of Construction and Facilities Management www.abovegroupinc.com COA/CA Lic. No. 31120

305 East Dr., Suite H, Melbounre, Florida 32904

PH: 321.345.9026

100% CONSTRUCTION

DOCUMENTS 25

NOT SPRINKLERED

B

IM

/0

C o rr e c t E le c tr ic a l D e fi c ie n c ie s /0

C o rr e c t E le c tr ic a l D e fi c ie n c ie s R

M

E P

F P

.r v t

/1

/2

:2

:4

A

M

573-19-616

KYLE J .DAVIS, P.E.

FL License #84275

MECHANICAL NEW WORK

FLOOR/ROOF PLAN - BLDG. 25

CORRECT ELECTRICAL

DEFICIENCIES

GAINESVILLE VA

07/13/2021 KJD MRK

MH101

0119039

0 2' 4' 8' 12'

1/4" = 1'-0" N

1/4" = 1'-0"MH101

1 MECHANICAL NEW WORK FLOOR PLAN - BLDG. 25

1/4" = 1'-0"MH101

2 MECHANICAL NEW WORK ROOF PLAN - BLDG. 25

CODED NOTES:

1. EQUIPMENT MOUNTED ON 4" CONCRETE PAD. CONCRETE PAD SHALL EXTEND 6" BEYOND

PERIMETER OF EQUIPMENT.

2. MANUFACTURER'S RECOMMENDED CLEARANCE.

3. EXPOSED SPIRAL DUCTWORK, DOUBLE-WALL INTERNALLY INSULATED. DUCTWORK SHALL BE

ROUTED TIGHT TO STRUCTURE ABOVE AND SHALL NOT BE ROUTED ABOVE ELECTRICAL

EQUIPMENT.

4. 3/4" CONDENSATE ROUTED FROM AHU-1 AND THRU WALL TO DISCHARGE 6" ABOVE SPLASHBLOCK.

CONDENSATE SHALL MAINTAIN A 1/8" SLOPE. SEAL WALL PENETRATION WATERTIGHT.

5. 6"Ø EA ROUTED UP TO EF 181 ON ROOF.

6. MAKEUP AIR THRU EXISTING LOUVER ABOVE DOOR. PROVIDE NEW 1" FILTER RACK ON BACK OF

EXISTING LOUVER AND PROVIDE WITH 1" GALVANIZED STEEL WASHABLE FILTER.

7. REFRIGERANT PIPING ROUTED TIGHT TO STRUCTURE. REFRIGERANT PIPING SHALL NOT BE ROUTED

OVER ELECTRICAL EQUIPMENT.

8. REFRIGERANT PIPING ROUTED TO AVOID ELECTRICAL EQUIPMENT.

9. EXISTING BATTERY ELECTRICAL EQUIPMENT. CONTRACTOR SHALL NOT INSTALL NEW UTILITIES

ABOVE EXISTING EQUIPMENT

10. EXISTING ELECTRICAL DISCONNECTS. CONTRACTOR SHALL NOT INSTALL NEW UTILITIES ABOVE

EXISTING DISCONNECTS.

11. ROUTED REFRIGERANT PIPING DOWN AND THRU WALL TO CU 67. SEAL WALL PENETRATION

WATERTIGHT.

12. EXHAUST DUCTWORK ROUTED AROUND EXISTING ELECTRICAL GEAR TO MAINTAIN PROPER

VERTICAL CLEARANCE FOR ELECTRICAL GEAR.

13. PROVIDE CURB ADAPTER FOR NEW EXHAUST FAN.

14. PROVIDE FLEXIBLE CONNECTION AT AHU DUCT CONNECTION.

XX

N.T.S.MH101

3 BLDG. 25 PHOTO 1

N.T.S.MH101

4 BLDG. 25 PHOTO 2

GENERAL NOTES:

1. BLDG. 25 PHOTO 2 SHOWN FOR REFERENCE FOR DUCTWORK ROUTING.

Revisions Date

P R

O F

E S

S

I O NA L

E N G

I N

E E

R

L I CENSE

F L O R I DA

STATE

No. 84275

SCOPE OF WORK

20.1 19.1 18.3 18.1 17.6

W.1

U

V

T.1

T

17.1

S

B 60002

T

IDU-1

IDU-2

MH102

T

MH102

20.1 19.1 18.3 18.1 17.6

W.1

U

V

T.1

T

17.1

S x3

S

A x3

R

A

AHU 66

ODU-1

M - MAIN FLOOR

88' - 9"

M - ROOF

108' - 1"

MEP Roof 66' - 1 1/32"

18.1

M - MAIN FLOOR

46' - 9 1/32"

36x18 SA 18x36 RA

VA FORM 08 - 6231

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

321 4 5 6 7 8 9 10

VA Project No.

AG Project No.

Project Number

Building

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

FULLY SPRINKLERED

U.S. Department of Veterans Affairs

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT Office of Construction and Facilities Management www.abovegroupinc.com COA/CA Lic. No. 31120

305 East Dr., Suite H, Melbounre, Florida 32904

PH: 321.345.9026

100% CONSTRUCTION

DOCUMENTS MEP

B

IM

/0

C o rr e c t E le c tr ic a l D e fi c ie n c ie s /0

C o rr e c t E le c tr ic a l D e fi c ie n c ie s R

M

E P

F P

.r v t

/1

/2

:2

:4

A

M

573-19-616

KYLE J .DAVIS, P.E.

FL License #84275

MECHANICAL NEW WORK

FLOOR/ROOF PLAN - MEP BLDG.

CORRECT ELECTRICAL

DEFICIENCIES

GAINESVILLE VA

07/13/2021 KJD MRK

MH102

0119039

0 2' 4' 8' 12'

1/4" = 1'-0" N

1/8" = 1'-0"MH102

1 MECHANICAL NEW WORK FLOOR PLAN - MEP BLDG.

1/8" = 1'-0"MH102

2 MECHANICAL NEW WORK ROOF PLAN - MEP BLDG.

CODED NOTES:

1. UTILIZE EXISTING PENETRATION AND ROOF CURB. SEAL CURB WATER TIGHT.

2. NEW CONCENTRIC DIFFUSER. CONCENTRIC DIFFUSER SHALL BE MOUNTED TIGHT TO STRUCTURE

ABOVE ELECTRICAL CONDUIT, BUT SO THAT STRUCTURE DOES NOT AFFECT AIRFLOW.

3. MANUFACTURER'S RECOMMENDED CLEARANCE.

4. REFRIGERANT PIPING UP THRU EXISTING CAPPED ROOF CURB AND TO OUTDOOR UNIT.

5. ROUTE 3/4" CONDENSATE TO NEAREST ROOF DRAIN LOCATED PLAN EAST OF COLUMN LINE 17.1, ADJACENT TO EXISTING COOLING TOWER. SLOPE PIPING AT 1/8" AND PROVIDE PIPING SUPPORTS AS

REQUIRED.

6. INDOOR UNIT SHALL BE MOUNTED AT HEIGHT ABOVE ELECTRICAL GEAR BUT BELOW SUSPENDED

LIGHTING (APPROXIMATELY 9'-0" ABOVE FINISHED FLOOR).

7. 3/4" CONDENSATE ROUTED FROM IDU-2 ALONG WALL AND UNDER IDU-1. SLOPE PIPING AT 1/8".

8. REFRIGERANT PIPING ROUTED FROM IDU-2 ALONG WALL AND UNDER IDU-1.

9. REFRIGERANT PIPING ROUTED FROM IDU-1 ALONG WALL.

10. REFRIGERANT PIPING ROUTED UP WALL AND OVER TO EXISTING ROOF PENETRATION.

11. 3/4" CONDENSATE ROUTED FROM IDU-1 DOWN TO TIE INTO 3/4" CONDENSATE FROM IDU-2.

12. 3/4" CONDENSATE ROUTED DOWN AND THRU WALL TO DISCHARGE AT SPLASHBLOCK.

13. COORDINATE FINAL CONDENSATE ROUTING WITH EXISTING EQUIPMENT. PIPING SHALL NOT BE

ROUTED ABOVE ELECTRICAL EQUIPMENT.

14. EXISTING LOUVER TO REMAIN.

15. EXISTING TO REMAIN DUCTWORK ROUTED ON ROOF.

16. PROVIDE OUTDOOR RATED FLEXIBLE CONNECTION AT AHU DUCT CONNECTION AND SEALED WATER

TIGHT.

XX

1/4" = 1'-0"MH102

3 MECHANICAL SECTION - MEP BLDG.

N.T.S.MH102

4 MEP BLDG. PHOTO 1

GENERAL NOTES:

1. MEP BLDG. PHOTO 1 SHOWN FOR REFERENCE FOR ROUTING OF NEW CONDENSATE.

P R

O F

E S

S

I O NA L

E N G

I N

E E

R

L I CENSE

F L O R I DA

STATE

No. 84275

SI

33 32 31

K.3

M

M.6

N

AHU 68

CU 68

C 900

C 900

C 900

C 900

C 900

2 1

EXISTING ELECTRICAL GEAR

EXISTING ELECTRICAL GEAR

18x30 SA

MH103

MH103

30x18 SA x1

S

A x1

S A x1

S

A x1

S A

T

5 6

KEY PLAN

SCOPE OF

WORK

VA FORM 08 - 6231

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

321 4 5 6 7 8 9 10

VA Project No.

AG Project No.

Project Number

Building

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

FULLY SPRINKLERED

U.S. Department of Veterans Affairs

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT Office of Construction and Facilities Management www.abovegroupinc.com COA/CA Lic. No. 31120

305 East Dr., Suite H, Melbounre, Florida 32904

PH: 321.345.9026

100% CONSTRUCTION

DOCUMENTS ACA

B

IM

/0

C o rr e c t E le c tr ic a l D e fi c ie n c ie s /0

C o rr e c t E le c tr ic a l D e fi c ie n c ie s R

M

E P

F P

.r v t

/1

/2

:2

:5

A

M

573-19-616

KYLE J .DAVIS, P.E.

FL License #84275

MECHANICAL NEW WORK FLOOR

PLAN - ACA BLDG.

CORRECT ELECTRICAL

DEFICIENCIES

GAINESVILLE VA

07/13/2021 KJD MRK

MH103

0119039

1/4" = 1'-0"MH103

1 MECHANICAL NEW WORK FLOOR PLAN - ACA BLDG.

0 2' 4' 8' 12'

1/4" = 1'-0" N

CODED NOTES:

1. EQUIPMENT MOUNTED ON 4" CONCRETE PAD. CONCRETE PAD SHALL EXTEND 6" BEYOND

PERIMETER OF EQUIPMENT.

2. MANUFACTURER'S RECOMMENDED CLEARANCE.

3. EXPOSED RECTANGULAR DUCTWORK, DOUBLE-WALL INTERNALLY INSULATED. DUCTWORK SHALL

NOT BE ROUTED ABOVE ELECTRICAL EQUIPMENT. DUCTWORK HEIGHT SHALL BE LOCATED ABOVE

ELECTRICAL GEAR AND ABOVE SUSPENDED LIGHTING. FINAL HEIGHT SHALL BE COORDINATED WITH

EXISTING SANITARY PIPING, SPRINKLER PIPING, AND ELECTRICAL CONDUIT.

4. 3/4" CONDENSATE AND REFRIGERANT PIPING ROUTED THRU EXISTING SHEET METAL/LOUVER.

CONDENSATE SHALL BE ROUTED AT 1/8" SLOPE AND SHALL DISCHARGE 6" ABOVE SPLASHBLOCK.

SEAL PENETRATION WATERTIGHT.

5. DUCTWORK SHALL BE ROUTED BELOW SANITARY PIPING.

6. DUCTWORK ROUTED UP AND ROUTED ACROSS ROOM ABOVE SANITARY PIPING AND BELOW FIRE

SPRINKLER PIPING.

7. PROVIDE FLEXIBLE CONNECTION AT AHU DUCT CONNECTION.

XX

N.T.S.MH103

4 ACA BLDG. PHOTO 1

GENERAL NOTES:

1. ACA PHOTO 3 & 4 SHOWN FOR REFERENCE FOR DUCTWORK ROUTING.

N.T.S.MH103

3 ACA BLDG. PHOTO 1

Revisions Date

P R

O F

E S

S

I O NA L

E N G

I N

E E

R

L I CENSE

F L O R I DA

STATE

No. 84275

18 GAUGE STAINLESS STEEL STRAPS

1" WIDE MIN (DO NOT BLOCK ACCESS

PANELS) 2-MIN PER 4'0". WRAP

CONTINUOUS OVER CONDENSER AND

SECURE TO CONCRETE PAD WITH

1/4"X1-1/2" STAINLESS STEEL

CONCRETE SCREWS OR ANCHORS.

(EACH SIDE)

4" THK FIBERMESH

REINFORCED

CONCRETE PAD

6" MIN

ALL

SIDES

CONDENSING UNIT

PROVIDE 6" CLEAR GRAVEL

AROUND CONDENSER. SOD

THEREAFTER.

W

1/ 3W

R

1/ 3W1/2W

W

2/3W

R

W

R

VANE

R SHALL

EQUAL

OR BE

GREATER

THAN W.

R SHALL

EQUAL OR

BE

GREATER

THAN 1/3W.

R SHALL

EQUAL OR

BE

GREATER

THAN 1/6W.

NOTES:

1. THE INTERIOR SURFACE OF ALL RADIUS ELBOWS SHALL BE MADE ROUND.

2. ALL STANDARD RADIUS ELBOWS CAN BE SUBSTITUTED WITH SHORT RADIUS ELBOWS. ALL SHORT RADIUS

ELBOWS SHALL HAVE VANES. VANES SHALL BE CONSTRUCTED, SUPPORTED AND FASTENED AS

RECOMMENDED BY SMACNA.

NOTES:

1. ALL VANE ELBOWS SHALL BE CONSTRUCTED AND INSTALLED AS DETAILED BY SMACNA.

2. WHEN W1 DOES NOT EQUAL W2, VANE SHALL BE SINGLE THICKNESS VANE TYPE REGARDLESS OF W

DIMENSION.

3. ALL SINGLE THICKNESS VANES SHALL HAVE A 2" [50mm] RADIUS, 1 1/2" [40mm] MAXIMUM SPACE

BETWEEN VANES AND A 3/4" [20mm] TRAILING EDGE.

4. WHEN W EQUALS W2 AND W1 IS GREATER THAN 20" [500mm] VANES SHALL BE DOUBLE VANE TYPE.

W1

W

ROUND FLEXIBLE CONNECTION

RECTANGULAR FLEXIBLE CONNECTION

FLANGED

CONNECTION ON

FAN SIDE

WASHER 1-1/2" [40mm] MIN. TO 3" [75mm] MAX. INSTALLED. 6" [150mm] NOMINAL WITH MATERIAL

TAUT

FLEXIBLE

MATERIAL AS

SPECIFIED

1"x1/8" [25x3mm] DRAW BAND

1"x1/8" [25x3mm] BAND IRON

BOLT ON 4" [100mm] CENTERS

5/16" [8mm] FLANGE

DUCT

SHEET METAL SCREWS

ON 12" [300mm]

CENTERS

RIVET ON 4"

[100mm]

CENTERS

SHEET METAL AS

SPECIFIED FOR

DUCTWORK.

1"x1/8" [25x3mm] BAND IRON

BOLT ON 4" [100mm] CENTERS

1" [25mm] FLANGE & HEMALTERNATE

POSITION OF

BOLT 1 1/2" [40mm]

POCKET SLIP

DUCT

SHEET METAL AS

SPECIFIED FOR

DUCTWORK.

[15mm] [15mm] [40mm]

1 1/2" [40mm] MIN. TO 3" [75mm] MAX. INSTALLED. 6" [150mm] NOMINAL WITH MATERIAL TAUT

FLANGED

CONNECTION

ON FAN SIDE

WASHER

FLEXIBLE MATERIAL AS

SPECIFIED

1/2" 1 1/2"1/2"

CURB CAP

SEAL WITH APPROVED FIRE

STOPPING MATERIAL

GALV. SHEET METAL HOOD WITH

SOLDERED SEAMS.

SEAL OPENING WATER

TIGHT FOLLOWING

INSTALLATION OF

PIPING TWO PIECE PIPE CLAMP

INSULATED

REFRIGERANT PIPING

1-5/8", 16 GA. SPOT

WELDED CHANNELS

BACK TO BACK

PITCH

4"X4"X1/4" THICK ALUM. PLATE

ANCHORED TO ROOF DECK.

ANCHORS SHALL NOT

PENETRATE THE ROOF DECK

MORE THAN 3/4"

NOTES:

1. FLASH AROUND PIPING SUPPORT COLUMN

2. PIPING SHALL BE SLOPED TOWARD THE CONDENSING UNITS

EXISTING ROOF

TAPERED INSULATION

20 GAUGE GALVANIZED

SHEETMETAL COVER

SLOPE

1-1/2" LONG, ONE WAY

SECURITY SCREWS W/

WASHER, INSTALL EVERY 4" O.C.

SEAL WATERTIGHT

EXISTING ROOF

CURB

ROOF

SIZE CAPS TO FIT EXISTING ROOF CURBS; FIELD VERIFY

EXACT DIMENTIONS

6" R-19 FIBERGLASS BATT

INSULATION

22 GAIGE INSULATION

LINER

SILICONE CAULK SEAL-

CONTINUOUS BEAD

BETWEEN LINER CURB

EDGE & CAP

3/4" CDX PLYWOOD

1/4" THICK

WOOD SHIM

BAND

OVER 50"∅

HANGER RODS

BAND OF

SAME SIZE AS

HANGER STRAP

LOAD RATED

FASTENERS

50"∅ & UNDER

NOTE:

TABULATED DATA FROM SMACNA ALLOWS FOR DUCT

REINFORCING AND INSULATION, BUT NO EXTERNAL LOAD.

420ONE 1 x 18 GA STRAP36

TWO 1/2∅ RODS

TWO 3/8∅. RODS

ONE 1 x 16 GA STRAP

50 700

ONE 1 x 22 GA STRAP

QUANTITY/SIZEMAX. DUCT ∅

HANGER STRAPS OR RODS

MAX. LOAD

LBS.

MAX.

IN.

SPACING

IN. IN.

UNION

DRAIN PAN (FURNISHED

WITH UNIT)

PRIMER PLUG

CLEAN OUT

PITCH DOWN

TOWARD DRAIN

L DIMENSIONS:

L = H + J + PIPE DIAMETER

H = 1 INCH FOR EACH INCH OF NEGATIVE

PRESSURE (INTERNAL PLUS RETURN

STATIC PRESSURE) + 1 INCH

J = 1/2 H

H

J

EXTERIOR

BUILDING WALL

INSULATED PIPING

INSULATION

REFRIGERANT PIPING

FIRE RATED CAULK

7/8" MAX. ANNULAR SPACE

NOTE: NON-INSULATED PIPING SIMILAR.

REFER TO ARCHITECTURAL FOR

FLASHING AND SEALING

REQUIREMENTS OF PENETRATION

ON EXTERIOR SIDE OF WALL

INTERIOR

BUILDING WALL

VA FORM 08 - 6231

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

321 4 5 6 7 8 9 10

VA Project No.

AG Project No.

Project Number

Building

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

U.S. Department of Veterans Affairs

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT Office of Construction and Facilities Management www.abovegroupinc.com COA/CA Lic. No. 31120

305 East Dr., Suite H, Melbounre, Florida 32904

PH: 321.345.9026

100% CONSTRUCTION

DOCUMENTS

B

IM

/0

C o rr e c t E le c tr ic a l D e fi c ie n c ie s /0

C o rr e c t E le c tr ic a l D e fi c ie n c ie s R

M

E P

F P

.r v t

/1

/2

:2

:3

A

M

573-19-616

KYLE J .DAVIS, P.E.

FL License #84275

MECHANICAL DETAILS CORRECT ELECTRICAL

DEFICIENCIES

GAINESVILLE VA

07/13/2021 KJD MRK

M-201

0119039

N.T.S.

CU MOUNTED ON GRADE

N.T.S.

DUCTWORK RADIUS ELBOWS DETAIL

N.T.S.

DUCTWORK SQUARE VANE ELBOWS DETAIL

N.T.S.

FLEXIBLE DUCT CONNECTIONS DETAIL

N.T.S.

REGRIGERANT PIPING ROOF CAP DETAIL

N.T.S.

ROOF CURB CAP DETAIL

N.T.S.

ROUND DUCT HANGERS

N.T.S.

CONDENSATE DRAIN TRAP W/ FORMULA DETAIL

N.T.S.

PIPING PENETRATION DETAIL

Revisions Date

P R

O F

E S

S

I O NA L

E N G

I N

E E

R

L I CENSE

F L O R I DA

STATE

No. 84275

PREFAB CURB BY EQUIP.

MFR.

12" MIN.

ROOF INSULATION

THICKNESS

VARIES

ROOF

SMOKE DETECTORS LOCATED IN AN

ACCESSIBLE LOCATION IN SA DUCT

J-BOX CONDUIT &

WIRE BY

DIV. 27

PACKAGED

A/C UNIT

ELECTRICAL

DISCONNECT AND

SERVICE

RECEPTACLE

RETURN AIR

CONNECTION

SUPPLY AIR

CONNECTION

NOTE: ALL ROOF MOUNTED EQUIPMENT MUST ADHERE TO CURRENT HURRICANE

CODES REGARDING ROOF TIE-IN AND WIND RESISTANCE.

MOTOR & DRIVE

U.L. APPROVED

ELECTRICAL DISCONNECT

BIRDSCREEN

SPONGE RUBBER PAD

(VIB. ISOL.)

EXISTING CURB

THERMAL &

ACOUSTICAL

INSULATION

BACKDRAFT

DAMPER

FLASHING

ROOF

CONSTRUCTION

EXHAUST

DUCTWORK

ALL ALUMINUM WHEEL

HUB & HOUSING

MOTOR DOME EXHAUST FAN

DISCHARGE

DOME

RING FLANGE. WELD

TO CURB CAP.

WEATHERPROOF GLASS

FAB. & MASTIC (2 LAYERS)

BETWEEN DUCT & RING

FLANGE COLLAR

GALV. METAL CURB

CAP. CROSS BREAK.

WELD CORNERS.

PRE-FAB ROOF CURB

CANT. (REF.)

ROOFING (REF.)

INSULATION (REF.)

STRUCTURAL DECK (REF.)

DUCT SUPPORT CLAMP

SECURE CURB TO

STRUCT. DECK.

8" M

IN

4" M

IN

WELDED STEEL ANGLE

SUPPORT. ATTACH TO CURB.

DUCT SUPPORT CLAMP

2" MIN.

DUCT

DUCT CLAMP

STEEL ANGLE

8" MIN.

NOTE:

1. ROUND DUCT SHOWN AS TYPICAL

2. SLOPE TOP OF DUCTWORK FROM PEAK

AT 10 DEGREESE FROM HORIZONTAL

ROOF SURFACE

PRE-FAB ROOF EQUIPMENT SUPPORT

(2) LAG SCREWS SILICONE CAULK

BENEATH HEAD BEFORE

TIGHTENING SIZE PER INSTALL

CLEARANCE REQUIREMENTS

FOR ROOFTOP EQUIPMENT

(DIMENSION A)

D

IM

E N

S

IO

N

A

WIDTH OF EQUIP.

(INCHES)

CLEARANCE

(INCHES)

UP TO 24

24 TO 36

37 TO 48

49 TO 60

61 & WIDER

SUPPLY AIR

RETURN AIR

PROVIDE FILTER SECTION WITH

HINGED ACCESS DOOR AND

LOCKS. PROVIDE 1" FILTER

RACK SECTION.

FLOOR SLAB

UNISTRUT P2481 PIPE

BRACKET ANCHOR UNISTRUT

SUPPORT TO FLOOR

CONDENSATE DRAIN

(INSULATED)

REFRIGERANT LINES

FLEX CONNECTION

4" CONCRETE HOUSEKEEPING

PAD. EXTEND 6" BEYOND

PERIMETER OF AHU

NOTE: AN OVERFLOW DEVICE SHALL

BE PROVIDED FOR CONDENSATE

CONTROL IN ACCORDANCE TO FBC -

MECHANICAL (2017) 307.2.3.

SIDE RETURN

SUPPLY DUCT

SINGLE CONTINUOUS

HANGER STRAP, ATTACH TO

STRUCTURE ABOVE.

LOUVERED SUPPLY

GRILLE WITH AIR

SCOOP

SUPPLY DUCT

SINGLE CONTINUOUS

HANGER STRAP, ATTACH

TO STRUCTURE ABOVE

LOUVERED SUPPLY

GRILLE WITH

OPPOSED BLADE

DAMPER.

VA FORM 08 - 6231

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

321 4 5 6 7 8 9 10

VA Project No.

AG Project No.

Project Number

Building

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

U.S. Department of Veterans Affairs

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT Office of Construction and Facilities Management www.abovegroupinc.com COA/CA Lic. No. 31120

305 East Dr., Suite H, Melbounre, Florida 32904

PH: 321.345.9026

100% CONSTRUCTION

DOCUMENTS

B

IM

/0

C o rr e c t E le c tr ic a l D e fi c ie n c ie s /0

C o rr e c t E le c tr ic a l D e fi c ie n c ie s R

M

E P

F P

.r v t

/1

/2

:2

:3

A

M

573-19-616

KYLE J .DAVIS, P.E.

FL License #84275

MECHANICAL DETAILS CORRECT ELECTRICAL

DEFICIENCIES

GAINESVILLE VA

07/13/2021 KJD MRK

M-202

0119039

N.T.S.

RTU INSTALLATION

N.T.S.

ROOF DOWNBLAST EXHAUST FAN DETAIL

N.T.S.

DUCT ROOF PENETRATION DETAIL

N.T.S.

ROOF DUCT SUPPORT DETIAL

N.T.S.

AHU INSTALL DETAIL

N.T.S.

EXPOSED DUCT SUPPLY GRILLE DETAIL

Revisions Date

P R

O F

E S

S

I O NA L

E N G

I N

E E

R

L I CENSE

F L O R I DA

STATE

No. 84275

EF-1 SEQUENCE OF OPERATION

1. GENERAL

A. FAN IS NORMALLY STARTED AND STOPPED REMOTELY AT THE ECC. EF-1 SERVES BATTERY STORAGE IN

BLDG. 25.

B. FAN SHALL RUN CONTINUOUSLY.

2. GRAPHICAL USER INTERFACE

A. GRAPHIC DISPLAY: PROVIDE A COMPLETE GRAPHIC DISPLAY OF THE SYSTEM AT THE ECC. THE DISPLAY SHALL

SHOW ALARM CAPABILITIES FOR FAN STATUS AND AIRFLOW INTERRUPTION.

ECC

SST

IT

EF-1

FAN

C O

O

LI

N G

C O

IL

F

IL

T E

R

RA

ROOM TEMPERATURE SENSOR, WALL MOUNTED 48" AFF.

T

UC

AHU 66, 67, & 68 UNIT SEQUENCE OF OPERATION

E

LE

C T

R

IC

H

E A

T

IN

G C

O

IL

COMPRESSOR

IF APPLICABLE

TT

AHU 66, 67, & 68

ECC

SST

IT

SA

1. GENERAL

A. AIR HANDLING UNIT SHALL REMAIN OPERATIONAL AT ALL TIMES.

B. AIR HANDLING UNIT SHALL BE THERMOSTATICALLY CONTROLLED TO CYCLE WITH LOADS THRU ITS

FACTORY PROVIDED CONTROLLER.

C. ALARM IF SPACE TEMPERATURE IS OUTSIDE OF RANGES FOR MORE THAN 10 MINUTES (ADJUSTABLE).

2. GRAPHICAL USER INTERFACE

A. GRAPHIC DISPLAY: PROVIDE A COMPLETE GRAPHIC DISPLAY OF THE SYSTEM AT THE ECC. THE DISPLAY SHALL

SHOW ALARM CAPABILITIES FOR FAN STATUS AND AIRFLOW INTERRUPTION.

EXISTING

EXISTING ENGINEERING

CONTROL CENTER -

ECC

NETWORK

EXISTING COMMUNICATION NETWORK

CLOSEST

UPSTREAM DEVICE

TO AHU 66

BACNET

BUILDING

CONTROLLER

MSTP

COMMUNICATION

(TYPICAL)

NOTES:

1. REUSE EXISTING COMMUNICATION NETWORK.

2. EXISTING CONTROL SYSTEM SOFTWARE TO REMAIN.

UPGRADE GRAPHICS ACCORDINGLY.

3. CONTROL SYSTEM ARCHITECTURE SHOWN IS FOR

DESIGN INTENT OF CONTROL SYSTEM. CONTROLS

CONTRACTOR SHALL ALTER SYSTEM ARCHITECTURE

AS REQUIRED TO BEST FIT NEW CONTROL SYSTEM

AND TIE IN TO EXISTING SYSTEM.

4. ALL NEW EQUIPMENT SHALL BE BACNET COMPATIBLE.

5. ALL NEW CONTROL POINTS SHALL BE ABLE TO BE

MONITORED AND ADJUSTED FROM THE EXISTING

CONTROLS FRONT END.

AHU 66

(NEW)

CLOSEST

UPSTREAM DEVICE

TO AHU 67

1st DEVICE IN LINE

(EXISTING)

AHU 67

(NEW)

CLOSEST

UPSTREAM DEVICE

TO AHU 68

AHU 68

(NEW)

CLOSEST

UPSTREAM DEVICE

TO EF-1

EF-1

(NEW)

VA FORM 08 - 6231

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

321 4 5 6 7 8 9 10

VA Project No.

AG Project No.

Project Number

Building

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

U.S. Department of Veterans Affairs

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT Office of Construction and Facilities Management www.abovegroupinc.com COA/CA Lic. No. 31120

305 East Dr., Suite H, Melbounre, Florida 32904

PH: 321.345.9026

100% CONSTRUCTION

DOCUMENTS

B

IM

/0

C o rr e c t E le c tr ic a l D e fi c ie n c ie s /0

C o rr e c t E le c tr ic a l D e fi c ie n c ie s R

M

E P

F P

.r v t

/1

/2

:2

:3

A

M

573-19-616

KYLE J .DAVIS, P.E.

FL License #84275

MECHANICAL SCHEDULES CORRECT ELECTRICAL

DEFICIENCIES

GAINESVILLE VA

07/13/2021 KJD MRK

M-301

0119039

MULTI-ZONE MINI-SPLIT DUCTLESS HEAT PUMP SCHEDULE

INDOOR UNIT OUTDOOR UNIT

MARK MODEL NO.

SA CFM

(MAX.)

TOTAL COOLING

CAPACITY (BTU/H)

TOTAL HEATING

CAPACITY (BTU/H)

UNIT ELECTRICAL

MARK MODEL NO.

NOM.

TONS

AMBIENT

TEMP. (°F)

UNIT ELECTRICAL

RATED

AMPS V/PH/HZ RATED AMPS MCA MOCP V/PH/HZ

IDU-1 ,2 LMN079HVT 250 7000 8100 0.4 208/1/60 ODU-1 LMU18CHV 1.3 95 11.1 13.3 20 208/1/60

AIR HANDLING UNIT SCHEDULE

MARK MODEL NO.

NOM.

TONS

SUPPLY FAN COOLING - DX HEATING COIL

WEIGHT

ELECTRICAL

SUPPLY

CFM

OUTSIDE AIR

CFM ESP (IN WG) MOTOR HP

EAT

(°F DB)

EAT

(°F WB)

MAX LAT

(°F DB)

TOT. CAP.

(MBH) REFRIGERANT TYPE

TOTAL CAP.

(KW) V/PH/HZ MCA MOP

AHU 67 TWE09044A 7.5 3300 NONE 1.0 3.0 76 63.7 55.0 89.8 R-410A ELETRIC 14.96 400 460/3/60 28 30

AHU 68 TWE12044A 10 4500 NONE 1.0 3.0 76 63.4 55.0 118.1 R-410A ELETRIC NONE 450 460/3/60 6 15

AIR-COOLED CONDENSING UNIT SCHEDULE

MARK MODEL NO. NOM. TONS

COMPRESSOR

QTY/RLA

FAN

QTY/FLA

REFRIGERANT

VOLTS/PH/HZ MCA MOP MIN. SEERTYPE GAS SIZE LIQUID SIZE

CU 67 TTA09044A 7.5 1/12.2 1/1.6 R-410A NOTE 2 NOTE 2 460/3/60 17 25 11.5

CU 68 TTA12044A 10 1/17.8 1/2.5 R-410A NOTE 2 NOTE 2 460/3/60 25 40 11.5

NOTES:

1. BASIS OF DESIGN MANUFACTURER IS TRANE.

2. SIZE REFRIGERANT LINES PER MANUFACTURER RECOMMENDATIONS. PROVIDE OVERSIZE LINES AND/OR REFRIGERATION LINE EXTENSION KIT BASED ON MANUFACTURERS RECOMMENDATIONS FOR EXTENDED

REFRIGERATION LINE RUNS.

3. AMBIENT DESIGN TEMPERATURE IS 95° F.

4. PROVIDE SINGLE POINT ELECTRICAL CONNECTION.

5. PROVIDE 5 YEAR COMPRESSOR WARRANTY.

6. PROVIDE ANTI-RECYCLE COMPRESSOR TIMER.

7. PROVIDE CONDENSER COIL GUARDS.

8. PROVIDE PROTECTIVE COATING ON CASING, BASE, FRAME AND CONDENSER COIL OF OUTSIDE CONDENSING UNIT. ACCEPTABLE PROVIDERS ARE GOLDFIN, BLYGOLD, LUVATA, AND BRONZ-GLOW. COIL COATING

SHALL BE APPLIED AFTER CONSTRUCTION OF THE COIL (COATED FIN STOCK IS NOT ACCEPTABLE). COATING SHALL BE DOCUMENTED TO ENDURE A MINIMUM OF 4,000 HOURS OF SALT SPRAY (ASTM B117).

COATING SHALL BE APPLIED BY THE FACTORY TRAINED AND CERTIFIED APPLICATOR.

NOTES:

1. BASIS OF DESIGN MANUFACTURER IS TRANE.

2. PROVIDE SIDE RETURN AND PROVIDE GRILLE AT RETURN INTAKE.

3. PROVIDE SINGLE POINT ELECTRICAL CONNECTION. STARTER, RELAY, HEATING ELEMENT, AND CONTROLS SHALL BE PART OF PACKAGED UNIT.

4. PROVIDE WITH 30% EFFICIENCY FILTERS.

5. PROVIDE HEAD PRESSURE CONTROLLER FOR OPERATION IN AMBIENT TEMPERATURE DOWN TO 30° F.

6. SIZE REFRIGERANT LINES PER MANUFACTURER RECOMMENDATIONS FOR SPECIFIC REFRIGERANT LINE RUN.

7. PROVIDE 7-DAY PROGRAMMABLE THERMOSTAT. UNITS SHALL BE THERMOSTATICALLY CONTROLLED TO CYCLE WITH LOADS. NO ADDITIONAL CONTROLS ARE REQUIRED.

NOTES:

1. BASIS OF DESIGN MANUFACTURER IS LG.

2. INDOOR UNITS AND OUTDOOR UNITS POWERED INDIVIDUALLY. PROVIDE SINGLE POINT ELECTRICAL CONNECTION FOR EACH IDU AND ODU.

3. DISCONNECT PROVIDED BY ELECTRICAL. REFER TO ELECTRICAL DRAWINGS.

4. PROVIDE LOW AMBIENT KIT FOR OPERATION IN AMBIENT TEMPERATURES DOWN TO 0° F.

5. SIZE REFRIGERANT LINES PER MANUFACTURER RECOMMENDATIONS. PROVIDE OVERSIZE LINES AND/OR REFRIGERATION LINE EXTENSION KIT BASED ON

MANUFACTURERS RECOMMENDATIONS FOR EXTENDED REFRIGERATION LINE RUNS.

6. PROVIDE 5 YEAR COMPRESSOR WARRANTY.

7. PROVIDE ANTI-RECYCLE COMPRESSOR TIMER.

8. PROVIDE CONDENSER COIL GUARDS.

9. PROVIDE PROTECTIVE COATING ON CASING, BASE, FRAME, AND CONDENSER COIL OF CONDENSING UNIT. ACCEPTABLE PROVIDERS ARE GOLDFIN, BLYGOLD, LUVATA, AND BRONZGLOW. COIL COATING SHALL BE APPLIED AFTER CONSTRUCTION OF THE COIL (COATED FIN STOCK IS NOT ACCEPTABLE). COATING SHALL BE DOCUMENTED TO ENDURE A MINIMUM OF 4,000 HOURS OF SALT SPRAY (ASTM B117). COATING SHALL BE APPLIED BY THE FACTORY TRAINED AND CERTIFIED

APPLICATOR.

10. PROVIDE 7 DAY PROGRAMMABLE THERMOSTAT. UNITS SHALL BE THERMOSTATICALLY CONTROLLED TO CYCLE WITH LOADS. NO ADDITIONAL CONTROLS ARE

REQUIRED.

AIR DISTRIBUTION SCHEDULE

MARK CFM NECK SIZE

FACE SIZE

LENGTH DESCRIPTION

A 0-950 18X12 18X12 SPIRAL DUCT SUPPLY GRILLE

BASIS OF DESIGN: PRICE - SDGE

COLOR: MATCH DUCTWORK

MATERIAL: ALUMINUM

AIR SCOOP: YES

B 0-6000 (2) 18X36 45.5X45.5 CONCENTRIC SUPPLY/RETURN DIFFUSER

BASIS OF DESIGN: RUSKIN - CDS-60

COLOR: WHITE

MATERIAL: ALUMINUM

OPPOSED BLADE DAMPER: NO

C 0-100 8X6 8X6 SIDEWALL EXHAUST GRILLE

BASIS OF DESIGN: PRICE - 80

COLOR: MATCH WALL

MATERIAL: ALUMINUM

OPPOSED BLADE DAMPER: NO

D 0-900 18X12 18X12 SUPPLY GRILLE

BASIS OF DESIGN: PRICE - 620DAL

COLOR: MATCH DUCT

MATERIAL: ALUMINUM

OPPOSED BLADE DAMPER: YES

EXHAUST FAN SCHEDULE

MARK BASIS OF DESIGN MODEL NO. TYPE CFM

ESP

(IN-WG)

FAN

RPM

ELECTRICAL DRIVE

TYPE

MAX

SONESHP NEC FLA V/PH/HZ

EF 181 GREENHECK G-097-VG CENTRIFUGAL

ROOF

100 0.3 917 1/4 2.85 115/1/60 DIRECT 3.0

NOTES:

1. PROVIDE FACTORY DISCONNECT SWITCH.

2. PROVIDE BACKDRAFT DAMPER.

3. EXHAUST FAN SHALL RUN CONTINUOUSLY.

4. PROVIDE MOTOR WITH SPEED CONTROL CAPABILITY.

5. PROVIDE SPARK PROOF FAN WITH EXPLOSION PROOF MOTOR.

6. PROVIDE ROOF CURB ADAPTOR.

7. EXHAUST FAN SHALL BE TIED INTO THE EXISTING ECC. REFER TO CONTROL DIAGRAM FOR CONTROL INFORMATION.

PACKAGED ROOFTOP AIR CONDITIONING UNIT SCHEDULE

MARK

BASIS OF

DESIGN MODEL NO.

NOMINAL

TONS

SUPPLY FAN

OUTSIDE AIR

(CFM)

COOLING COIL - DX

ELECTRIC

HEAT

WEIGHT

(LBS)

ELECTRICAL

NOMINAL

CFM

ESP

(IN-WG)

MOTOR

HP

DRIVE

TYPE CFM

EAT

(F° DB)

EAT

(F° WB)

MAX. LAT

(F° DB)

GROSS TOTAL

MBH

GROSS

SENSIBLE MBH

AMBIENT TEMP.

(F°) REFRIGERANT

MIN. EFFICIENCY

(EER) V/PH/HZ MCA MOP

AHU 66 TRANE THD180 15.0 6000 1.0 3.0 BELT NONE 6000 76.0 62.8 54.9 165.8 136.9 100 R-410A 12.1 NONE 2500 460/3/60 33 45

NOTES:

1. PROVIDE SIDE SUPPLY DISCHARGE AND SIDE RETURN INTAKE CONNECTIONS.

2. PROVIDE FACTORY UNIT MOUNTED DISCONNECT WITH HOA SWITCH AND PILOT LIGHTS.

3. PROVIDE 115V DUPLEX GROUND FAULT PROTECTED ELECTRICAL OUTLET WITH POWER SUPPLY INDEPENDENT OF UNIT DISCONNECT.

4. PROVIDE PROTECTIVE COATING ON CASING, BASE, FRAME, AND CONDENSER COIL. ACCEPTABLE PROVIDERS ARE BLYGOLD, LUVATA AND BRONZ-GLOW. COIL COATING SHALL BE APPLIED AFTER CONSTRUCTION OF THE

COIL (COATED FIN STOCK IS NOT ACCEPTABLE). COATING SHALL BE DOCUMENTED TO ENDURE A MINIMUM OF 4,000 HOURS OF SALT SPRAY (ASTM B117). COATING SHALL BE APPLIED BY THE FACTORY OR BY A FACTORY

TRAINED AND CERTIFIED APPLICATOR.

5. PROVIDE MANUFACTURER'S INTEGRATED CONTROLS PACKAGE CAPABLE OF PROGRAMMABLE CONTROL.

6. PROVIDE PREFABRICATED ROOF CURB TO EXTEND A MINIMUM OF 8" ABOVE FINISHED ROOF.

7. PROVIDE PROTECTIVE COATING ON CASING, BASE, FRAME AND CONDENSER COIL OF OUTSIDE CONDENSING UNIT. ACCEPTABLE PROVIDERS ARE GOLDFIN, BLYGOLD, LUVATA, AND BRONZ-GLOW. COIL COATING SHALL

BE APPLIED AFTER CONSTRUCTION OF THE COIL (COATED FIN STOCK IS NOT ACCEPTABLE). COATING SHALL BE DOCUMENTED TO ENDURE A MINIMUM OF 4,000 HOURS OF SALT SPRAY (ASTM B117). COATING SHALL BE

APPLIED BY THE FACTORY TRAINED AND CERTIFIED APPLICATOR.

N.T.S.

EF-1 CONTROL DIAGRAM

3 N.T.S.

AIR HANDLING UNIT CONTROLS

2 N.T.S.

BACNET SYSTEM ARCHITECTURE

CODED NOTES:

1. CONTROLS PART OF "BID ALTERNATE NO. 1 - REMOVE AHU 66, 67, & 69 CONTROLS" INDICATED IN

SPECIFICATIONS.

XX

Revisions Date

P R

O F

E S

S

I O NA L

E N G

I N

E E

R

L I CENSE

F L O R I DA

STATE

No. 84275

1PH SINGLE-PHASE

1P SINGLE POLE

2/C TWO-CONDUCTOR

3/C THREE-CONDUCTOR

3PH THREE-PHASE

4/C FOUR-CONDUCTOR

4W FOUR-WIRE

A/C UNIT AIR CONDITIONING UNIT

A/E ARCHITECT/ENGINEER

AAP ALARM ANNUNCIATOR PANEL

AC ALTERNATING CURRENT OR ARMORED CABLE

ACC ACCESSIBLE

ADDL ADDITIONAL

ADJ ADJACENT, ADJOINING

ADO AUTOMATIC DOOR OPENER

AF AMPERE FRAME OR AMP FUSE

AFC ABOVE FINISHED COUNTER, AUTOMATIC FREQUENCY

CONTROL, OR AVAILABLE FAULT CURRENT

AFF ABOVE FINISHED FLOOR

AFG ABOVE FINISHED GRADE

AH AMPERE HOUR

AHJ AUTHORITY HAVING JURISDICTION

AIC AMPERE INTERRUPTING CAPACITY

ALT ALTERNATE

AMB OR A AMBIENT

AMP AMPERE

ARCH ARCHITECT

ASC AMPS SHORT CIRCUIT

AT AMPERE TRIP

ATS AUTOMATIC TRANSFER SWITCH

AUTO AUTOMATIC

AV AUDIO VISUAL

BAT BATTERY

BC BARE COPPER

BD BOARD

BFF BELOW FINISH FLOOR

BIL BASIC INSULATION LEVEL

BLDG BUILDING

BPIP BOILER PLANT INSTRUMENTATION PANEL

BRKR BREAKER

BYP BY PASS

C CONDUIT

CAB CABINET

CALC CALCULATE

CAP CAPACITY

CAT CATALOG

CATV COMMUNITY ANTENNA TELEVISION

CCR CONTROL CONTACTOR

CCTV CLOSED CIRCUIT TELEVISION

cd CANDELA

CD CONSTRUCTION DOCUMENTS

CF CONTRACTOR FURNISHED

CF/CI CONTRACTOR FURNISHED/CONTRACTOR INSTALLED

CF/OI CONTRACTOR FURNISHED/OWNER INSTALLED

CFE CONTRACTOR FURNISHED EQUIPMENT

CHW CHILLED WATER

CHWP CHILLED WATER PUMP

CKT CIRCUIT

CKT BRKR CIRCUIT BREAKER

CLF CURRENT LIMITING FUSE

CLG CEILING

CMU CONCRETE MASONRY UNIT

COAX COAX CABLE

COMM COMMUNICATION

COMPT COMPARTMENT

CONC CONCRETE

CONT CONTINUE

CONTR CONTRACTOR

COORD COORDINATE

CPT CONTROL POWER TRANSFORMER

CRI COLOR RENDERING INDEX

CT CURRENT TRANSFORMER

CTV CABLE TELEVISION

CU COPPER

CU FT CUBIC FEET

CUR CURRENT

DB DECIBEL OR DIRECT BURIAL

DC DIRECT CURRENT

DCP DIMMER CONTROL PANEL

DEG C DEGREES CELSIUS

DEG F DEGREES FAHRENHEIT

DEMO DEMOLITION

DIAG DIAGRAM

DISC DISCONNECT

DISTR DISTRIBUTION

DISTR PNL DISTRIBUTION PANEL

DMR SW DIMMER SWITCH

DN DOWN

DPDT DOUBLE POLE, DOUBLE THROW

DPST DOUBLE POLE, SINGLE THROW

DRSW DOOR SWITCH

DS DISCONNECT SWITCH

DWG DRAWING

EC EMPTY CONDUIT

EG EQUIPMENT GROUND

EL ELEVATION

ELEC ELECTRIC OR ELECTRICAL

ELEV ELEVATOR

EMCP EMERGENCY MONITORING CONTROL PANEL

EMER EMERGENCY

EMI ELECTROMAGNETIC INTERFERENCE

EMT ELECTRICAL METALLIC TUBING

ENCL ENCLOSURE

EPO EMERGENCY POWER OFF

EPRF EXPLOSION PROOF

ESMT EASEMENT

EWC ELECTRIC WATER COOLER

EWH ELECTRIC WATER HEATER

EXIST EXISTING

ELECTRICAL ABBREVIATIONS

FA FIRE ALARM

FAAP FIRE ALARM ANNUNCIATOR PANEL

FABL FIRE ALARM BELL

FABX FIRE ALARM BOX

FACP FIRE ALARM CONTROL PANEL

FC FOOTCANDLE

FI FILM ILLUMINATOR

FIXT FIXTURE

FLA FULL LOAD AMPS

FLEX FLEXIBLE METALLIC CONDUIT

FLT FLOODLIGHT

FLUOR FLUORESCENT

FLUOR FIX FLUORESCENT FIXTURE

FOUTT TELEPHONE FLOOR OUTLET

FP FIRE PROTECTION

FT FEET OR FOOT

FU SW FUSED SWITCH

FVNR FULL VOLTAGE NON-REVERSING

FVR FULL VOLTAGE REVERSING

G OR GND GROUND OR GENERATOR

GEN…

This is the start of the file's text. The full file is on GovTribe.