J-7 MSC Ship Repair Facility Survey.doc
DOC document 109 KB Posted
- Attached to
- USNS MEDGAR EVERS (T-AKE 13) Mid-Term Availability (MTA) Federal contract opportunity
- Solicitation number
- N3220520R4112
About this file
This document is a ship repair facility survey form and supporting solicitation for the USNS MEDGAR EVERS (T-AKE 13) FY21 Mid-Term Availability. The Military Sealift Command requires ship repair services including maintenance, modernization, and regulatory inspections for the vessel. Offerors must complete the facility survey form providing details of their shipyard facilities, equipment, and experience. The solicitation requires services from June 2020 to September 2020 at a total evaluated price. Offerors must submit proposals by April 2020 and award is expected in May 2020. US shipyards certified under the Navy Shipyard Industrial Fund are eligible to compete for this requirement from the Department of the Navy's Military Sealift Command.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| N3220520R4112 Amend 0005.docx | DOCX document | |
| N3220520R4112 Amend 0004.docx | DOCX document | |
| N3220520R4112 Amend 0003.docx | DOCX document | |
| N3220520R4112 Amend 0002.docx | DOCX document | |
| J-A USNS MEDGAR EVERS MTA FY21.Redacted.REV01.pdf | ||
| N3220520R4112 Amend 0001.docx | DOCX document | |
| J-14 Technical NDA.docx | DOCX document | |
| J-13- Past Perf Questionaire.MEV.docx | DOCX document | |
| J-A USNS MEDGAR EVERS TAKE 13 MTA FY21.Redacted.pdf | ||
| Exhibit A CDRLs DD Form 1423.zip | ZIP file | |
| J-2 Category A Items.xlsx | XLSX spreadsheet | |
| J-3 Category B Items.xlsx | XLSX spreadsheet | |
| Solicitation N3220520R4112.pdf | ||
| J-4 MEV MTA FY21 GFP REPORT.pdf | ||
| J-8 RFC.doc | DOC document | |
| J-12 Past Perf Data.docx | DOCX document | |
| J-9 Disclsr Lobbying Activities SF-LLL.doc | DOC document | |
| J-10 Interport Differential.docx | DOCX document |
Show all 18
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
N3220520R4112
USNS MEDGAR EVERS
SHEET 1 OF 5
MSC SHIP REPAIR FACILITY SURVEY
NOTE: If survey form has been previously submitted, then enter changes only.
DATE:
SHIPYARD AND ADDRESS
Commander (Code M-4E3)
Military Sealift Command
Norfolk, VA 23511
SHIPYARD DATA
Telephone No:
Telex No:
Date Found:
BUILDING WAYS (M. I. W.)
NO. LAUNCHING DIMENSIONS MAXIMUM SHIP SIZE
OF (check one) (ton 2,240 lbs)
WAY
[ ] END LENGTH: LENGTH:
[ ] SIDE
[ ] BASIN WIDTH: WIDTH:
[ ] SLAB
DEPTH: DEPTH:
DEPTH OF WATER
CRANES SERVING WAY
CERTIFICATION DATE &
CERTIFIED BY WHOM
LIFT CAPACITY
(std. tons)
TYPE
NO.
AT DROP
OFF
OVER
WAY END
[ ] BASIN WIDTH: WIDTH:
[ ] BASIN WIDTH: WIDTH:
[ ] BASIN WIDTH: WIDTH:
[ ] BASIN WIDTH: WIDTH:
[ ] BASIN WIDTH: WIDTH:
LENGTH OF LAUNCHING RUN DEPTH OF RUN AT M.L.W.
TIDAL RANGE (DIFF. OF M.L. M.H)
IS SNUBBING NECESSARY?
YES NO
IS FIRE PROTECTION AVAILABLE
ON BUILDING WAY?
YES NO
DOCK
MAXIMUM SHIP SIZE
ACCOMMODATED
LENGTH OA-BEAM
LENGTH
at coping (GD), at keel blocks
OVERALL on cradle (MR), on PONTOON
(FD)
CLEAR WIDTH
at top cradle (MR), at keel at top inboard block wing wall (FD, GD) height
DEPTH/DRAFT
OVER OVER OVER
SILL FLOOR KEEL
(GD) BLOCKS
LIFTING CAPACITY
(ton 2,240)
DATE CERTIFIED, CERTIFIED BY WHOM, &
DATE CERTIFICATION EXPIRES
DRY DOCKS (continued)
MATERIAL TYPE
Floating--(FD)
Graving--(GD) Marine Railway (MR)
SERVICES AVAILABLE
(use abbreviation of service below)
USE
REPAIR/
OUTFIT-
ING
HEIGHT
OF
(M.L.W.)
OUT-
BOARD
IN-
BOARD
TYPE
LENGTH
(actual & usable)
ACT:
USE:
WATER DEPTH
(M. L. W.)
BERTHS OF SHIPS (Piers, Wharves, Bulkheads, etc.) DRY DOCKS (means high water)
MSC SHIP REPAIR FACILITY SURVEY (continued) SHIPYARD:
LEGEND (abbreviation of services)
Fresh Water --- F.W. - G.P.M. - P.S.I. Steam --- S - P/HR - P.S.I. Electric Power --- E - V - AC - AMP Fire Protection --- FP - G.P.M. - P.S.I.
Salt Water ----- S.W. - G.P.M. - P.S.I Air ------ A - C.F.M. - P.S.I. Electric Power --- E - V- DC - AMP Sanitary Sewer --SS - YES - NO
MSC SHIP REPAIR FACILITY SURVEY (continued) SHIPYARD:
BERTHING, SHOP OR YARD CRANES; STATIONARY, RAIL, MOBILE, OR BRIDGE (3 tons or over)
MAX REACH HEIGHT OF HOOK
NO TYPE CAPACITY MAX SPAN CAPACITY BOOM HEIGHT ABOVE BASE HEIGHT OF HOOK AREA SERVICE DATE CERTIFIED, CERTIFIED BY WHOM &
(STD TONS) (BRIDGE) AT REACH LENGTH HINGE ABOUT REACH (BRIDGE) DATE CERTIFICATION EXPIRES
DISTANCE TO NEAREST DISTANCE TO NEAREST AIRPORT
RAILROAD CONNECTION (identify)
NAVIGATIONAL RESTRICTIONS (indicate at M.L.W.)
MINIMUM CHANNEL (depth width) MINIMUM HORIZONTAL AND VERTICAL BRIDGE CLEARANCES
LIST ANY OTHER RESTRICTIONS (include projects under construction which will after navigational restrictions)
SHIPYARD:
MSC SHIP FACILITY SURVEY (continued)
STORAGE SPACE FOR COMPONENTS AND MATERIALS
(LIST DIMENSIONS FOR EACH AREA, PLUS TYPE MATERIAL STORED)
PRINCIPAL SHOPS AND BUILDINGS
ALL OTHER SHOPS
(LIST NAMES AND DIMENSIONS)
LARGEST EXIT
WIDTH HEIGHT
DIMENSIONS OF
SHOP OR BUILDING
NAME OF SHOP
OR BUILDING
FABRICATING
PLATE
SHEET METAL
SUBASSEMBLY
WOOD WORKING
BOAT ASSEMBLY
OR MOLDING
BOILER
MACHINE
ELECTRICAL
ELECTRONIC
PIPE
FOUNDRY
RIGGER
RAW STEEL STORAGE (SQ. FT.) ___________________________________________________________
WELDING AND ASSEMBLY (SQ. FT.) _______________________________________________________
ACREAGE LEGALLY CONTROLLED
IN USE DEVELOPED TOTAL
LIST TYPES OF WORK NORMALLY SUBCONTRACTED
SHIPYARD:
MSC SHIP REPAIR FACILITY SURVEY (continued)
LIST ANY EQUIPMENT OR CAPABILITY NOT OTHERWISE DESCRIBED IN THIS FORM
REQUIRED SUBMITTALS TO ACCOMPANY THIS FORM:
1. PLOT PLAN OF YARD.
2. CERTIFIED DEPTH OF WATER PLOT
3. FOR EACH SHOP LISTED ON SHEET 4, A LIST OF MACHINE TOOLS AND
EQUIPMENT WHICH INDICATES THE CAPACITIES OF THE SHOP.
4. A GENERAL STATEMENT (INCLUE, NAME OF SHIP, DATES, AND
DOLLAR AMONT OF JOB) OF SHIP REPAPIR WORK WHICH HAS BEEN
ACCOMPLISHED BY THE APPLICANT.
5. LISTING OF OFFICIALS AND THE QUALIFICATIONS OF EACH FOR SHIP
REPAIR (INCLUDE AS A MINIMUM JOBS HELD, YEARS, HELD, ONE LINE
6. IF FACILITIES ARE LOCATED AT MORE THAN ONE LOCATION THEN
LIST EACH FACILITY AND ITS LOCATION.
7. POINT OF CONTACT FOR INFORMATION SUBMITTED IN THIS FORM
(NAME/TITLE/PHONE NUMBER).
NORMAL
SHIFTS
NORMAL
MAXIMUM
POTENTIAL MAXIMUM
CURRENT
CURRENT
EMPLOYMENT
MANAGEMENT, ADMINISTRATION
PROFESSIONAL ENGINEERING
PRODUCTION SKILLED
PRODUCTION UNSKILLED
NONPRODUCTION
TOTAL:
ARE YOU CERTIFIED AS A SMALL BUSINESS ? YES NO
NAME AND TITLE OF SENIOR SURVEYOR SIGNATURE DATE SIGNED
PAGE
ATTACHMENT J - 7
MSC Form 4330/26
File details come from the government source that posted it. Updated .