J-3. Drawings 21-016A_2021-05-17_B1170 R171 Breakroom Renovations N66604-21-Q-0642.pdf
PDF 2 MB Posted
- Solicitation number
- N66604-21-Q-0642
View the file
Other files
Show all 14
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
WORK REQ. NO.
D E
P A
R
TM
E N
T O
F
TH
E N
A V
Y
N E
W P
O R
T, R
H O
D E
IS
LA
N D
FA
C
IL
IT
IE
S
B R
A N
C H
N A
V A
L U
N D
E R
S E
A W
A R
FA
R
E C
E N
TE
R
D
IV
IS
IO
N
SHEET OF
CONTRACT NO.
NAVFAC DRAWING NO.
NUWC DRAWING NO.
SCALE:
SIZE: ANSI D
A P
P R
O V
E D
C H
E C
K E
D B
Y
D E
S
IG
N E
D B
Y
D R
A W
N B
Y
D A
TE
S A
TI
S
FA
C
TO
R
Y T
O D
A
TE
D A
TE
D A
TE
D A
TE
R E
V
IS
IO
N
S S
Y M
D E
S C
R
IP
TI
O
N D
A
TE
A P
P R
AS NOTED
B U
IL
D
IN
G
N
U W
C D
IV
N
W P
T
B R
E A
K R
O O
M R
E
FU
R B
IS
H
M E
N T
TI
TL
E S
H E
E T
21-016A
S .T
IL
LE
Y
S .T
1 11
T-1
SCALE: NTS
1. NEW CONSTRUCTION IS SHOWN IN DARK BLACK. ITEMS TO BE REMOVED ARE SHOWN AS DASHED LINES. EXISTING FEATURES AND ITEMS TO REMAIN ARE
SHOWN IN GRAY.
2. THE CONTRACTOR SHALL CONFORM TO ALL STATE, NATIONAL AND OTHER CODES AND ORDINANCES WHICH APPLY TO THIS PROJECT.
3. THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL PERMITS WHICH ARE REQUIRED FOR THE SATISFACTORY COMPLETION OF THE WORK.
4. THE CONTRACTOR SHALL PROVIDE TO THE GOVERNMENT ALL SAFETY DATA SHEETS (SDS) IN ACCORDANCE WITH NUWC HAZARDOUS MATERIAL CONTROL (HAZCON) PROGRAM FOR ALL HAZARDOUS MATERIALS. REVIEW AND APPROVAL IS REQUIRED PRIOR TO BRINGING MATERIAL ON SITE. TYPICAL ITEMS REQUIRING SDS SHEETS INCLUDE PAINTS, ADHESIVES, SEALANTS, CAULKING, JOINT COMPOUND, ETC.
5. THE CONTRACTOR SHALL IDENTIFY AND FIELD VERIFY POINTS OF CONNECTION WHERE EXISTING AND NEW CONSTRUCTION MEET AND REPORT ANY DISCREPANCIES TO THE CONTRACTING OFFICER. THE CONTRACTOR SHALL PROCEED WITH THE WORK ONLY AFTER THE DISCREPANCIES HAVE BEEN
RESOLVED BY THE GOVERNMENT.
6. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS IN THE FIELD PRIOR TO ORDERING MATERIAL.
7. THE CONTRACTOR SHALL GAIN GOVERNMENT APPROVAL REGARDING COLORS RELATED TO THIS PROJECT. ALL PAINT SHALL BE ZERO V.O.C. TYPE. A COLOR
BOARD SHALL BE SUBMITTED FOR REVIEW AND APPROVAL.
8. THE CONTRACTOR SHALL PROVIDE ALL NECESSARY COMPONENTS AND PERFORM ALL WORK RELATED TO THIS PROJECT UNLESS OTHERWISE NOTED.
9. THE CONTRACTOR SHALL REMOVE AND RE-INSTALL ALL WALL AND CEILING MOUNTED ITEMS (SIGNAGE, ELECTRICAL DEVICES, ETC.). UNLESS ITEM IS
SCHEDULED FOR DEMOLITION. IF LEFT IN PLACE, PROTECT ITEMS DURING WORK.
10. THE CONTRACTOR SHALL REPAIR OR REPLACE ANY EQUIPMENT OR SURFACE TO REMAIN THAT IS DAMAGED BY HIS/HER OPERATIONS, AS APPROVED BY THE CONTRACTING OFFICER AT NO ADDITIONAL COST TO THE GOVERNMENT. DAMAGED SURFACES SHALL MATCH EXISTING FINISHES AND COLOR.
11. THE CONTRACTOR SHALL DISPOSE OF AND/OR RECYCLE CONSTRUCTION DEBRIS FROM THE PROJECT SITE IN A MANNER APPROVED BY STATE AND FEDERAL
REGULATIONS.
12. THE CONTRACTOR SHALL LEAVE THE CONSTRUCTION SITE IN A NEAT AND CLEAN MANNER AT THE END OF EACH WORKING DAY.
13. THE BUILDING WILL REMAIN OCCUPIED AND IN OPERATION DURING THE WORK. PORTIONS OF THE BUILDING OUTSIDE THE WORK AREA WILL REMAIN
OCCUPIED AND SECURED. CONTRACTOR SHALL PROTECT THESE OCCUPANTS FROM DUST, NOISE, AND FUMES DURING EXECUTION OF THE WORK. THE
WORK AREA WILL REMAIN CLOSED DURING CONSTRUTION.
INDEX OF DRAWINGS
GENERAL NOTES:
WORK AREA: BUILDING 1170 EXISTING PLAN
LOCATION MAP
C U
N N
IN
G
H A
M
BUSHNELL
E
FE
N S
E H
IG
H
W A
Y
CUNNINGHAM
LAY STREET
S T
R E
E T
FULTON
P O
R T
E R
S T
R E
E T
H U N
T STR
EET
LEAVITT STR
EET
ERICSON
C U N N
IN
G H
AM
P O
R T E R
S T R
E E T
STREET
LAY STREET
STR
EET
F U
L T O
N
STREET
STREET
S T R
E E
T
C U
N N
IN
G
H A
M S
T R
E E T
D E
F E
N S
E H
IG
H
W A
Y
C H
A S
E S
L A
N E
S T R
E E
T
FLEET ACCESS ROAD
BOOM STREET
N O
R T H
H O
W E L L S
T R
E E T
FU
LTO
N
S T R
E E T
S T
R E
E T
W A N U M
E T O N O M Y
G O L F & C O U N T R Y C L U B
PIER N0. 1
N A
R R
A G
A N
S E
T T
B A
Y
PIER N0. 2
WARFARE CENTER
NAVAL UNDERSEA
FACILITIES
BUILDING
GATE 23
TO ROUTE 114
GATE 32
THE SCOPE OF THIS RENOVATION PROJECT INCLUDES WORK TO BE
PERFORMED IN THE CURRENT ROOM 171 BREAK ROOM. WORK INCLUDES
PAINTING, REMOVING EXISTING ASBESTOS CONTAINING FLOOR TILES AND
MASTIC, NEW FLOORING, NEW CABINETS, NEW CEILING GRID AND CEILING
TILES, ELECTRICAL UPGRADES, NEW LIGHTING, NEW PLUMBING, AS WELL AS,
ALL OTHER INCIDENTAL WORK FOR A COMPLETE AND USABLE FACILITY.
SCOPE OF WORK:
SHEET
NUMBER
NUWCDIVNPT
DWG. NO. DWG. NUMBER
DISCIPLINE
DRAWING TITLE
1 OF 11 TITLE SHEETT-1
18-055A
D-1 ARCHITECTURAL DEMOLITION PLAN
A-1
A-2
A-3
NEW FLOOR PLAN
FIXTURE/ ACCESSORY PLAN
BUILDING 1170
ROOM 171 BREAK ROOM RENOVATIONS
NAVAL UNDERSEA WARFARE CENTER
NEWPORT, RI FACILITIES BRANCH
INDEX OF DRAWINGS
PROJECT SITE
BUILDING 1170
18-055A
18-055A
18-055A
E-1 EXISTING/ NEW LIGHTING PLAN18-055A
P-118-055A EXISTING/ NEW PLUMBING
FP-118-055A EXISTING/ NEW FIRE PROTECTION
WORK AREA
18-055A EXISTING/ NEW CEILING PLAN
BUILDING LOCATION
5/
/2
5/
/2
5/
/2
P O
R T
E R
S T
R E
E T C U N N
IN
G H
AM
BLDG. 1170
WORK
AREA
M-1 EXISTING/ NEW HVAC PLAN18-055A6 OF 11
E-2 EXISTING/ NEW ELECTRICAL PLAN18-055A8 OF 11
E-3 LIGHTING DETAILS18-055A9 OF 11
W2020-321-01
GATE 17
R .N
E
LS
O N
AutoCAD SHX Text
SEAL
AutoCAD SHX Text
STONE
AutoCAD SHX Text
BREAKWATER
AutoCAD SHX Text
CREEK
AutoCAD SHX Text
STOP
AutoCAD SHX Text
STOP
AutoCAD SHX Text
STOP
AutoCAD SHX Text
STOP
AutoCAD SHX Text
STOP
AutoCAD SHX Text
STOP
AutoCAD SHX Text
STOP
AutoCAD SHX Text
STOP
AutoCAD SHX Text
STOP
AutoCAD SHX Text
PROPANE
AutoCAD SHX Text
TANKS
AutoCAD SHX Text
BUSHNELL STREET
AutoCAD SHX Text
BUSHNELL STREET
AutoCAD SHX Text
BASIN "C"
AutoCAD SHX Text
BASIN "B"
AutoCAD SHX Text
BASIN "A"
AutoCAD SHX Text
HEADQUARTER STREET
AutoCAD SHX Text
RAILROAD RIGHT OF WAY
AutoCAD SHX Text
CHILLER
AutoCAD SHX Text
CHILLER
AutoCAD SHX Text N
AutoCAD SHX Text N
AutoCAD SHX Text N
AutoCAD SHX Text
STOP
AutoCAD SHX Text
STOP
AutoCAD SHX Text
STOP
AutoCAD SHX Text
STOP
E
P A
R
TM
E N
T O
F
TH
E N
A V
Y
N E
W P
O R
T, R
H O
D E
IS
LA
N D
FA
C
IL
IT
IE
S
B R
A N
C H
N A
V A
L U
N D
E R
S E
A W
A R
FA
R
E C
E N
TE
R
D
IV
IS
IO
N
SHEET OF
CONTRACT NO.
NAVFAC DRAWING NO.
NUWC DRAWING NO.
SCALE:
SIZE: ANSI D
A P
P R
O V
E D
C H
E C
K E
D B
Y
D E
S
IG
N E
D B
Y
D R
A W
N B
Y
D A
TE
S A
TI
S
FA
C
TO
R
Y T
O D
A
TE
D A
TE
D A
TE
D A
TE
R E
V
IS
IO
N
S S
Y M
D E
S C
R
IP
TI
O
N D
A
TE
A P
P R
AS NOTED
B U
IL
D
IN
G
A
R C
H
IT
E C
TU
R
A L
D E
M O
LI
TI
O N
P
LA
N
21-016A
S .T
IL
LE
Y
S .T
2 11
D-1
EXISTING DEMOLITION PLAN
SCALE: 14" = 1'-0"
LEGEND:
SPECIFIC DEMOLITION NOTES
DENOTES PHOTO NUMBER AND LOCATION TAKEN1
APPROX. 850 SQ.FT. OF ASBESTOS FLOOR TILE AND
MASTIC TO BE REMOVED.
EXISTING FLOORING TO BE REMOVED
SCALE: 14" = 1'-0"
B R
E A
K R
O O
M R
E N
O V
A
TI
O N
S
ASBESTOS DEMOLITION NOTE:
EXISTING VINYL FLOOR TILE AND MASTIC CONTAIN ASBESTOS
AND SHALL TO BE REMOVED AND DISPOSED OF PROPERLY
USING PROPER STATE AND FEDERAL ABATEMENT
PROCEDURES. ANY ITEMS NOT PART OF THIS PROJECT AND
REMAINING GOVERNMENT PROPERTY REQUIRING TO BE
REMOVED BEFORE ASBESTOS ABATEMENT WILL BE REMOVED
BY THE GOVERNMENT.
DEMOLITION NOTES:
EXISTING CABINETS TO BE REMOVED AND DISPOSED OF PROPERLY.
SINK IN COUNTERTOPS TO BE REMOVED AND DISPOSED OF PROPERLY.
ALL ASSOCIATED PLUMBING TO REMAIN FOR RECONNECTION TO NEW
KITCHEN CABINET AND SINK.
CEILING GRID AND CEILING TILE TO BE REMOVED AND DISPOSED OF
PROPERLY (DASHED). ALL LIGHTING FIXTURES TO BE REMOVED AND
DISPOSED OF PROPERLY (DASHED). ALL EMERGENCY LIGHTS,
SPRINKLER HEADS, HVAC REGISTERS TO BE REMOVED. ALL ITEMS WILL
BE REUSED UNLESS OTHERWISE NOTED IN DRAWINGS. SEE SHEET A-3.
PROVIDE PROPER SUPPORT AS NECESSARY WHILE CEILING
SUSPENSION SYSTEM IS REPLACED.
EXISTING FLOOR TILE AND MASTIC TO BE REMOVED. FLOOR TILE AND
MASTIC CONTAIN ASBESTOS AND SHOULD BE REMOVED AND DISPOSED
OF BY A LICENSED ASBESTOS REMEDIATION COMPANY. ASBESTOS
REMEDIATION COMPANY SHALL FOLLOW GOVERNMENT AND STATE
LAWS FOR REMEDIATION AND DISPOSAL OF MATERIALS. THIRD PARTY
AIR QUALITY CONTROL COMPANY SHALL BE USED TO CLEAR THE AREA
BEFORE WORK CAN PROCEED. REFER TO SPECIFICATION SECTION
02 82 00 ASBESTOS REMEDIATION.
ELECTRICAL OUTLETS ON WALL WHERE EXISTING CABINETS ARE
LOCATED SHALL BE REMOVED. CIRCUITS TO REMAIN IN USE WHILE
CONSTRUCTION IS GOING ON. THESE CIRCUITS WILL BE REUSED AFTER
NEW WALL IS INSTALLED FOR NEW CABINETS INSTALLATION. SEE
SHEET E-2.
EXISTING WATER FOUNTAIN TO BE REMOVED AND DISPOSED OF
PROPERLY.
REMOVE AND RETURN TO GOVERNMENT EXISTING CEILING MOUNTED
PROJECTOR AND ASSOCIATED CEILING MOUNTED SCREEN.
ASSOCIATED ELECTRICAL TO BE RUN BACK TO NEAREST JUNCTION
BOX. CIRCUIT TO REMAIN INTACT. SEE SHEET E-1 FOR DETAILS
5/
/2
5/
/2
5/
/2
1 PHOTO 1
2 PHOTO 2
EXISTING PHONE TOWER TO
REMAIN. PHONE TOWER TO
BE ROTATED TO FIT INTO
NEW MECHANICAL CLOSET.
SEE SHEET E-2.
EXISTING CEILING
MOUNTED
REGISTERS AND
DIFFUSERS TO BE
REMOVED AND
REPLACED AFTER
NEW CEILING GRID
IS INSTALLED.
(TYP.8)
EXISTING CABINETS (WATER FOUNTAIN)
TO BE REMOVED AND DISPOSED OF
PROPERLY. ALL ASSOCIATED PLUMBING
TO REMAIN. SOAP DISPENSER AND
PAPER TOWEL DISPENSER TO BE
REMOVED AND REINSTALLED.
EXISTING REFRIGERATORS TO
BE MOVED OUT OF AREA (BY
GOVERNMENT) TEMPORARILY
UNTIL PROJECT IS COMPLETE.
SEE REFLECTED CEILING PLAN
A-3.
EXISTING FLOOR TILE AND
MASTIC TO BE REMOVED
AND DISPOSED OF
PROPERLY. FLOOR TILE
AND MASTIC CONTAIN
ASBESTOS.
W2020-321-01
EXISTING LIGHTS TO BE REMOVED AND DISPOSED OF
PROPERLY. CIRCUIT TO REMAIN INTACT DURING
REMODEL. SEE SHEET E-1 FOR DETAILS.
EXISTING HVAC SUPPLY REGISTER TO BE REMOVED
AND DISPOSED OF PROPERLY. SEE SHEET M-1 FOR
DETAILS.
EXISTING HVAC RETURN REGISTER TO BE REMOVED
AND DISPOSED OF PROPERLY. SEE SHEET M-1 FOR
DETAILS.
EXISTING CONCRETE/CMU BLOCK WALL.
28'-511 16"
30'-2"
R .N
E
LS
O N
EXISTING CMU
BLOCK WALL
SEAL
E
P A
R
TM
E N
T O
F
TH
E N
A V
Y
N E
W P
O R
T, R
H O
D E
IS
LA
N D
N A
V A
L U
N D
E R
S E
A W
A R
FA
R
E C
E N
TE
R
D
IV
IS
IO
N
SHEET OF
CONTRACT NO.
NAVFAC DRAWING NO.
NUWC DRAWING NO.
SCALE:
SIZE: ANSI D
A P
P R
O V
E D
C H
E C
K E
D B
Y
D E
S
IG
N E
D B
Y
D R
A W
N B
Y
D A
TE
S A
TI
S
FA
C
TO
R
Y T
O D
A
TE
D A
TE
D A
TE
D A
TE
R E
V
IS
IO
N
S S
Y M
D E
S C
R
IP
TI
O
N D
A
TE
A P
P R
AS NOTED
21-016A
S .T
IL
LE
Y
S .T
3 11
A-1
B U
IL
D
IN
G
N
E W
F
LO
O R
P
LA
N
NEW WALL TO BE INSTALLED USING METAL STUDS AND 5 8" GWB. WALL TO BE PREPPED FOR TWO (2) COATS OF PRIMER AND TWO (2) COATS OF PAINT (GRAY SCREEN #SW7071). SEE THIS SHEET FOR WALL SECTION DETAIL
(WALL SECTION "A").
NEW WALL TO BE INSTALLED USING METAL STUDS AND 5 8" GWB. WALL TO BE PREPPED FOR TWO (2) COATS OF PRIMER AND TWO (2) COATS OF PAINT (GRAY SCREEN #SW7071). SEE THIS SHEET FOR WALL SECTION DETAIL
(WALL SECTION "B").
NEW CEILING GRID AND TILES TO BE INSTALLED (SHEET A-3). ADD NEW LIGHTING FIXTURES AS SHOWN ON
SHEET E-2.
NEW LIGHTS ARE TO BE 2x2 LED, AND UTILIZE EXISTING CIRCUITS FROM EXISTING POWER PANEL.
SEE SHEET A-3 AND E-1 FOR LIGHTING LAYOUT.
NEW CABINETS TO BE INSTALLED. SEE NEW CABINET ELEVATION ON SHEET A-2.
NEW DOOR TO BE INSTALLED IN NEW WALL . SEE DOOR DETAILS ON SHEET A-2.
PROVIDE A 20"x 25"x 8" DEPTH (MINIMUM) UNDER-MOUNT STAINLESS STEEL BAR SINK WITH HOT AND COLD
WATER AND GOOSE NECK STYLE FAUCET.
CONSTRUCTION NOTES:
LEGEND:
1 INDICATES WORK NOTES
INDICATES WALL DETAIL (SEE WALL DETAILS ON THIS
SHEET)
1/4"=1'-0"
5' 0' 5' 10' 15' 20'
FA
C
IL
IT
IE
S
B R
A N
C H
A A 4
INDICATES DETAIL SECTION OR ELEVATION
INDICATES ELEVATION NUMBER OR SECTION LETTER
INDICATES SHEET
GRAPHIC SCALE
W2020-321-01
NEW FLOOR PLAN
SCALE: 14" = 1'-0"
NEW FLOOR PLAN W/ DIMENSIONS
SCALE: 14" = 1'-0"
B R
E A
K R
O O
M R
E N
O V
A
TI
O N
S
1/2"=1'-0" 1'
0' 5' 10'6' 7' 8' 9'4'3'2'1'
REF.
REF.
171 171
7'-7"
8'
12'
7'-101 2"
10'-31 2"
FLOOR TILE (SEE
FINISH SHEET A-3)
SLAB ON GRADE
2x4 METAL STUDS 16" O.C.
8" FIRE RATED
GWB BOARD.
NEW SUSPENDED
CEILING 9'-0" A.F.F.
NEW WALL SECTION
SCALE: 12" = 1'-0"
A
9'-55 8"
MECH.
ROOM
MECH.
ROOM
FLOOR TILE (SEE
FINISH SHEET A-3)
SLAB ON GRADE
2x6 METAL STUDS
16" O.C. FOR
PLUMBING AND
ELECTRICAL
NEW SUSPENDED
CEILING 9'-0" A.F.F.
NEW WALL SECTION
SCALE: 12" = 1'-0"
2" AIR GAP BETWEEN
EXISTING WALL AND
NEW STUD WALL
REF.
REF.
3.
4.
4'-11 4"
NEW SUSPENDED
CEILING 9'-0" A.F.F.
5/
/2
5/
/2
5/
/2
NEW LOCATION
OF PAPER TOWEL
DISPENSER
EXISTING CMU
BLOCK WALL
INDICATES NEW WALL TO BE INSTALLED. SEE WALL
SECTIONS ON THIS SHEET.
101 INDICATES NEW DOOR TO BE INSTALLED. SEE
SHEET A-2 FOR DETAILS.
EXISTING CONCRETE/CMU BLOCK WALL.
WALL TO BE 12" ABOVE
SUSPENDED CEILING. WALL
TO BE BRACED TO ROOF
DECK
WALL TO BE 12" ABOVE
SUSPENDED CEILING. WALL
TO BE BRACED TO ROOF
DECK
8" FIRE RATED
GWB BOARD.
8" FIRE RATED
GWB BOARD.
B
A
A
A
B
MECHANICAL
ROOM SIDE
R .N
E
LS
O N
PROVIDE WOOD
BLOCKING WHERE
NEEDED FOR CABINET
INSTALLATION.
A 2 2
ADD MINERAL
WOOL INSULATION
FOR SOUND.
STUD WALL TO SIT ON
TOP OF FINISHED FLOOR
STUD WALL TO SIT ON
TOP OF FINISHED FLOOR
2'-6"EXISTING CMU
BLOCK WALL
E
P A
R
TM
E N
T O
F
TH
E N
A V
Y
N E
W P
O R
T, R
H O
D E
IS
LA
N D
N A
V A
L U
N D
E R
S E
A W
A R
FA
R
E C
E N
TE
R
D
IV
IS
IO
N
SHEET OF
CONTRACT NO.
NAVFAC DRAWING NO.
NUWC DRAWING NO.
SCALE:
SIZE: ANSI D
A P
P R
O V
E D
C H
E C
K E
D B
Y
D E
S
IG
N E
D B
Y
D R
A W
N B
Y
D A
TE
S A
TI
S
FA
C
TO
R
Y T
O D
A
TE
D A
TE
D A
TE
D A
TE
R E
V
IS
IO
N
S S
Y M
D E
S C
R
IP
TI
O
N D
A
TE
A P
P R
AS NOTED
21-016A
S .T
IL
LE
Y
S .T
4 11
A-2
B U
IL
D
IN
G
FI
X
TU
R E
/ A C
C E
S S
O R
Y P
LA
N
FA
C
IL
IT
IE
S
B R
A N
C H
NEW FLOORING PLAN
SCALE: 14" = 1'-0"
WALL COLOR IN LUNCHROOM. WALL COLOR
FOR ROOM 171 TO BE SHERWIN WILLIAMS
#SW7071 GRAY SCREEN WITH EGGSHELL
FINISH. TRIM PAINT TO BE FLAT BLACK.
PAINT
B R
E A
K R
O O
M R
E N
O V
A
TI
O N
S
ARMSTRONG VINYL PLANK FLOORING-
CASTLE LUXURY VINYL TILE-
COLOR: SILVER MINE 7.2in Wide x 48in Long
APPROX. 1000 SQ.FT. W/ 20% OVERAGE.
BASE MOLDING TO BE: JOHNSONITE RECESS
VINYL WALL BASE, RWDC-63 "BURNT UMBER"
FLOORING
CABINETS TO BEMANUFACTORED BY
"CLASSIC". COLOR TO BE DARTMOUTH
HONEY. SOFT CLOSE DOORS AND DRAWERS
TO BE INCLUDED.
CABINET HARDWARE: SATIN STEEL KNOBS
FOR PULL DRAWERS AND HANDLES FOR
DOORS
CABINETS
B36 B36 B36 B36
U3630 U3615
COUNTER TOP TO BE GRANITE WITH 4" BACK
SPLASH. COLOR TO BE BLUE PEARL GRANITE.COUNTER TOP
3' 3' 3' 3' 3'
BORED LOCKSET SEE
HARDWARE SCHEDULE
FOR HARDWARE
REQUIREMENTS
F-1
16 GAUGE STEEL FRAME
(KNOCK DOWN TYPE)
SOLID CORE
WOOD DOOR
FRAME
SIZE (inches)
W
ID
T H
H E
IG
H
T
T H
IC
K
DOOR
T Y
P E
M A
T
M A
T
REMARKS
H E
A D
T Y
P E
T H
R E
S
J A
M B
DETAILS
H A
R D
W A
R E
L A
B E
L F
IR
E R
A T
IN
G
S E
T N
O
D O
O R
N O
F R
O M
T H
IS
S
H E
E T
DOOR AND FRAME SCHEDULE NOTE:
ALL HARDWARE SHALL BE SATIN STAINLESS STEEL FINISH, GRADE 1
36 84 1 3/4 W A STEEL F1 -1 1 - 101
HW-101
· 1 12 PAIR HINGES - ANSI/BHMA A156.1 4 12"x 4 12" TYPE A8111
HEAVY DUTY
· 1 BORED LOCKSET - ANSI/BHMA A156.2 SERIES 4000, GRADE 2,
FUNCTION F86, STOREROOM FUNCTION PROVIDE
INTERCHANGEABLE CYLINDER TO ACCEPT 6 PIN CORE
MANUFACTURED BY "BEST" (PREFER STANLEY/BEST 7KC SERIES)
· 3 EA - DOOR SILENCERS
· 1 BORED LOCKSET FOR DEADBOLT
F-1
DOOR HARDWARE
3'-4"
7'-2"
2" 2"
5/
/2
5/
/2
5/
/2
6'-111 2"
2'-10"
2'-101 2"
1'-3"
1'-6"
15'
NEW CABINET ELEVATION
SCALE: 12" = 1'-0"
W2020-321-01
NEW DOOR AND FINISH PLAN
SCALE: 14" = 1'-0"
A 2 2
JAMB 1 HEADER 1
ANODIZED ALUMINUM FRAME:
· FRAME TO BE 16 GAUGE
· PROVIDE THE PROPER ANCHORS FOR ADJOINING
STEEL STUD CONSTRUCTION
· PREP AND REINFORCE FRAME AS NECESSARY
FOR THE SPECIFIED HARDWARE
FRAME DETAILS
NTS
U3615 U3630
BORED LOCKSET
FOR DEADBOLT
TYPE "A"
NOTE: AFTER REMOVAL OF ASBESTOS
CONTAINING FLOOR AND MASTIC, THE
CONTRACTOR SHALL PREP AND LEVEL
FLOOR AS NECESSARYTO INSTALL NEW
FLOORING IN ACCORDANCE WITH
MANUFACTER'S INSTRUCTIONS
R .N
E
LS
O N
E
P A
R
TM
E N
T O
F
TH
E N
A V
Y
N E
W P
O R
T, R
H O
D E
IS
LA
N D
N A
V A
L U
N D
E R
S E
A W
A R
FA
R
E C
E N
TE
R
D
IV
IS
IO
N
SHEET OF
CONTRACT NO.
NAVFAC DRAWING NO.
NUWC DRAWING NO.
SCALE:
SIZE: ANSI D
A P
P R
O V
E D
C H
E C
K E
D B
Y
D E
S
IG
N E
D B
Y
D R
A W
N B
Y
D A
TE
S A
TI
S
FA
C
TO
R
Y T
O D
A
TE
D A
TE
D A
TE
D A
TE
R E
V
IS
IO
N
S S
Y M
D E
S C
R
IP
TI
O
N D
A
TE
A P
P R
AS NOTED
21-016A
S .T
IL
LE
Y
S .T
5 11
A-3
B U
IL
D
IN
G
E
X
IS
TI
N
G / N
E W
C E
IL
IN
G P
LA
N
NEW REFELECTED CEILING PLAN
SCALE: 14" = 1'-0"
LEGEND:GENERAL NOTES
L1
1 WORK NOTE.
NEW 2x2 CEILING GRID, INTERMEDIATE DUTY; 15
16" WIDE;
PROVIDE WIRE SUPPORTS AT 4' O.C. MAXIMUM SPACING.
NEW 2x2 CEILING TILES, ARMSTRONG - ULTIMA HEALTH
ZONE HIGH NRC, BEVELED TEGULAR (WHITE) HUMIDITY
AND SAG RESISTANT
PROPOSED 2x2 LED LIGHTING FIXTURE. SEE FIXTURE "L1"
ON SHEET E-3 FOR FIXTURE DETAILS
EXISTING LIGHTING TO BE REMOVED, PACKAGED FOR RECYCLING AND DISPOSED OF PROPERLY.
EXISTING HVAC SUPPLY AND RETURN DIFFUSER TO BE REMOVED. SEE SHEET M-1 FOR INFORMATION ON
MECHANICAL.
EXISTING CEILING GRID AND CEILING TILES TO BE REMOVED AND DISPOSED OF. (BOLD DASHED LINES)
EXISTING CEILING MOUNTED PROJECTOR AND SCREEN TO BE REMOVED. PROJECTOR SHALL BE RETURNED
TO GOVERNMENT FOR STORAGE. SCREEN SHALL BE DISPOSED OF PROPERLY.
NEW 2 x 2 CEILING GRID TO BE INSTALLED WITH NEW MOISTURE RESISTANT 2 x 2 CEILING TILES.
NEW LIGHTS TO BE INSTALLED (TYPICAL OF 9). SEE SHEET E-1 FOR DETAILS.
NEW HVAC SUPPLY AND RETURN DIFFUSER TO BE INSTALLED. SEE SHEET M-1 FOR DETAILS.
WORKING NOTES
FA
C
IL
IT
IE
S
B R
A N
C H
EXISTING REFLECTED CEILING PLAN
SCALE: 14" = 1'-0"
INDICATES EXISTING LIGHTS TO BE REMOVED. EXISTING
LAMPS AND BALLASTS TO BE BOXED AND RETURNED TO
THE GOVERNMENT FOR RECYCLING. SEE SHEET E-1 FOR
LIGHTING PLANS.
1. CONTRACTOR SHALL VERIFY ALL DIMENSIONS IN THE FIELD PRIOR TO ORDERING MATERIAL.
2. CEILING HEIGHT TO BE 9'-0".
3. EXISTING EMERGENCY LIGHTS TO BE REPLACED USING NEW LEAD CALCIUM FIXTURE UTILIZING EXISTING LOCATION. SEE SHEET E-1 FOR LIGHTING PLAN AND SHEET E-3 FOR FIXTURE DETAILS.
EXISTING 2x4 CEILING GRID TO BE REMOVED AND
DISPOSED OF PROPERLY.
B R
E A
K R
O O
M R
E N
O V
A
TI
O N
S
SP
EXISTING PENDANT SPRINKLER HEAD TO BE REMOVED.
SP
NEW PENDANT SPRINKLER HEAD LOCATION.
EXISTING HVAC SUPPLY DIFFUSER TO BE REMOVED.
NEW HVAC SUPPLY DIFFUSER.
L1 L1 L1
L1L1L1
L1 L1 L1
5/
/2
5/
/2
5/
/2
EXISTING HVAC RETURN REGISTER TO BE REMOVED.
NEW HVAC RETURN REGISTER.
W2020-321-01
(TYPICAL)
(TYPICAL)
(TYPICAL)
(TYPICAL)
TT
D E
P A
R
TM
E N
T O
F
TH
E N
A V
Y
N E
W P
O R
T, R
H O
D E
IS
LA
N D
N A
V A
L U
N D
E R
S E
A W
A R
FA
R
E C
E N
TE
R
D
IV
IS
IO
N
SHEET OF
CONTRACT NO.
NAVFAC DRAWING NO.
NUWC DRAWING NO.
SCALE:
SIZE: ANSI D
A P
P R
O V
E D
C H
E C
K E
D B
Y
D E
S
IG
N E
D B
Y
D R
A W
N B
Y
D A
TE
S A
TI
S
FA
C
TO
R
Y T
O D
A
TE
D A
TE
D A
TE
D A
TE
R E
V
IS
IO
N
S S
Y M
D E
S C
R
IP
TI
O
N D
A
TE
A P
P R
AS NOTED
21-016A
S .T
IL
LE
Y
S .T
6 11
M-1
B U
IL
D
IN
G
E
X
IS
TI
N
G / N
E W
H V
A C
P
LA
N
NEW HVAC PLAN
SCALE: 14" = 1'-0"
LEGEND:
1 SPECIFIC WORK NOTE
FA
C
IL
IT
IE
S
B R
A N
C H
EXISTING HVAC PLAN
SCALE: 14" = 1'-0"
B R
E A
K R
O O
M R
E N
O V
A
TI
O N
S
INDICATES EXISTING HVAC SUPPLY REGISTER TO BE MOVED
INDICATES NEW HVAC SUPPLY REGISTER
34x16 38x16 x6 x1
24x22 x6 x1
9x12 CFM
2- 9x12 CFM'S
335 EA.
9x12 CFM
12x12 CD
12x12 CD
12x12 CD
12x12 CD x6 x1 x6 x1
9x12 CFM
2- 9x12 CFM'S
335 EA.
9x12 CFM
12x12 CD
12x12 CD
12x12 CD
12x12 CD
12x12 CD
HVAC DEMOLITION NOTES:
NEW FRESH AIR SUPPLY AND RETURN TO BE PROVIDED FOR REENOVATION.
INDICATES FRESH AIR RETURN TO BE RELOCATED AS INDICATED AFTER NEW
CEILING GRID AND TILES HAVE BEEN INSTALLED. SEE SHEET A-1 FOR NEW
LOCATION WITHIN NEW CEILING GRID.
1.
NEW HVAC NOTES:
NEW AIR SUPPLY DUCT TO BE CONNECTED TO EXISTING 24x22 DUCT WITH 6"
ROUND DUCT (SEE BRANCH CONNECTION DETAIL ON THIS SHEET). NEW AIR
RETURN TO BE CONNECTED TO EXISTING 38x16 MAIN RETURN DUCT WITH 6x6
DUCT WORK.
INDICATES LOCATION OF NEW AIR RETURN. NEW RETURN REGISTER TO MATCH
EXISTING SURFACE MOUNTED WITH SATIN FINISH.
NEW AIR SUPPLY AIR DUCT 6" ROUND. NEW SUPPLY TO MATCH EXISTING SURFACE
MOUNTED WITH SATIN FINISH.
INDICATES NEW LOCATION OF EXISTING AIR RETURN. PROVIDE MODIFICATIONS TO
EXISTING DUCT WORK AS REQUIRED.
5.
7.
DUCT MAIN
SPIN TAP SHALL
BE FULL SIZE OF
DIFFUSER NECK
WITH VD.
INSULATE
DIFFUSER NECK
OPPOSED BLADE
DAMPER
T-BAR
CEILING DIFFUSER (TYP.)
SUSPENDED CEILING
BAND AT
DIFFUSER NECK
DIFFUSER NECK
ATTACH METALLIC FLEX
DUCT TO DIFFUSER
NECK WITH BAND (MAX
LENGTH OF 5'-0")
BAND
DIFFUSER CONNECTION DETAIL
NTS
BRANCH CONNECTION DETAIL
NTS
MAIN DUCT
45°
BRANCH DUCT
VOLUME DAMPER
NOTE: THIS CONNECTION SHALL BE
USED AT ALL BRANCHES FROM
MAINS AND SUB-MAINS. BALANCING
DAMPERS SHALL BE PROVIDED.
8" ROUND DUCT
INDICATES EXISTING HVAC RETURN DIFFUSER TO BE MOVED
INDICATES NEW HVAC RETURN DIFFUSER
T INDICATES EXISTING THERMOSTAT LOCATION
5/
/2
5/
/2
5/
/2
2 2
2 2
6 6
8 8 8
W2020-321-01
1 SPECIFIC DEMOLITION NOTE
RETURN DUCT
SUPPLY DUCT
R .N
E
LS
O N
9x12 CFM
RETURN DUCT
34x16 38x16
24x22
RETURN DUCT
SUPPLY DUCT
RETURN DUCT
J J J
J J J
J J J
J J J
S
WORK REQ. NO.
D E
P A
R
TM
E N
T O
F
TH
E N
A V
Y
N E
W P
O R
T, R
H O
D E
IS
LA
N D
N A
V A
L U
N D
E R
S E
A W
A R
FA
R
E C
E N
TE
R
D
IV
IS
IO
N
SHEET OF
CONTRACT NO.
NAVFAC DRAWING NO.
NUWC DRAWING NO.
SCALE:
SIZE: ANSI D
A P
P R
O V
E D
C H
E C
K E
D B
Y
D E
S
IG
N E
D B
Y
D R
A W
N B
Y
D A
TE
S A
TI
S
FA
C
TO
R
Y T
O D
A
TE
D A
TE
D A
TE
D A
TE
R E
V
IS
IO
N
S S
Y M
D E
S C
R
IP
TI
O
N D
A
TE
A P
P R
AS NOTED
21-016A
S .T
IL
LE
Y
S .T
7 11
E-1
B U
IL
D
IN
G
E
X
IS
TI
N
G / N
E W
L
IG
H
TI
N G
P
LA
NFA
C
IL
IT
IE
S
B R
A N
C H
B R
E A
K R
O O
M R
E N
O V
A
TI
O N
S
LEGEND:
GENERAL NOTES
L1
1 WORK NOTE
NEW 2'x 2' LED LIGHTING FIXTURE. SEE FIXTURE "L1" ON
SHEET E-1 FOR DETAILS
WORKING NOTES
INDICATES EXISTING LIGHTS TO BE REMOVED. EXISTING
BALLASTS AND LAMPS TO BE BOXED FOR RECYCLING
PURPOSES. SEE THIS SHEET FOR LIGHTING REMOVAL.
INDICATES EXISTING EMERGENCY LIGHTS TO BE REMOVED. SEE
THIS SHEET FOR DETAILS. BATTERY TO BE BOXED FOR
RECYCLING PURPOSES.
1/4"=1'-0"
5' 0' 5' 10' 15' 20'
GRAPHIC SCALE
SPECIFIC DEMOLITION NOTES1
INDICATES EXISTING CEILING MOUNTED LIGHTS TO BE REMOVED
AND DISPOSED OF PROPERLY.
INDICATES EXISTING EMERGENCY LIGHTS TO BE REMOVED AND
DISPOSED OF PROPERLY. NEW EMERGENCY LIGHTS TO INSTALLED
IN SAME LOCATION (1).
3 INDICATES NEW 2x2 LIGHT FIXTURES TO BE INSTALLED . SEE
LIGHTING PLATE "L1" ON SHEET E-3.
4 INDICATES NEW EMERGENCY LIGHTS TO BE INSTALLED IN SAME
LOCATION AS THE ONES THAT WERE REMOVED. SEE LIGHTING PLATE
"L3" ON SHEET E-3.
5.
1. CONTRACTOR SHALL VERIFY ALL DIMENSIONS IN FIELD PRIOR TO ORDERING MATERIALS.
2. UNLESS INDICATED OTHERWISE, ALL ITEMS IN BOLD ARE NEW.
3. ALL ELECTRICAL WIRING SHALL BE IN ACCORDANCE WITH ALL APPLICABLE LOCAL, STATE AND FEDERAL REGULATIONS AND SHALL COMPLY WITH THE NEWEST EDITION OF THE NATIONAL ELECTRICAL
CODE (NEC) AND THE NATIONAL ELECTRICAL SAFETY CODE (NESC).
4. ALL NEW CONDUIT AND WIRING SHALL BE CONCEALED TO THE GREATEST EXTENT POSSIBLE ABOVE SUSPENDED CEILING AND WITHIN NEW WALLS. ALL NEW CIRCUITS SHALL UTILIZE 3/12'S IN 3 4" EMT UNLESS INDICATED OTHERWISE. AT THE CONTRACTORS OPTION, ALL PORTIONS OF 20 AMP BRANCH CIRCUITS CONCEALED WITHIN WALLS OR ABOVE SUSPENDED CEILING MAY UTILIZE METAL CLAD CABLE CONTAINING 3# 12'S (COLOR CODED). ALL WIRING SHALL BE COPPER. ALL WIRING OF SIZES NO.10 AND
SMALLER SHALL BE SOLID VICE STRANDED CONSTRUCTION.
5. CONTRACTORS SHALL PROVIDE A GREEN INSULATED EQUIPMENT GROUND CONDUCTOR IN ALL
CIRCUITS AND TO ALL NON-CURRENT CARRYING METALLIC ITEMS.
6. ALL NEW PENETRATIONS SHALL BE SEALED. ALL HOLES LEFT BY REMOVALS SHALL BE PREPARED AND PAINTED TO MATCH EXISTING ADJACENT SURFACES. ALL HOLES LEFT IN ELECTRICAL BOXES, PANELS, COVERS,...ETC. SHALL BE PROVIDED WITH KNOCKOUT CLOSURE PIECES.
7. ALL SWITCHES, SENSORS, DEVICES AND DEVICE PLATES,...ETC. SHALL BE WHITE IN COLOR.
EXISTING LIGHTING PLAN
SCALE: 14" = 1'-0"
NEW LIGHTING PLAN
SCALE: 14" = 1'-0"
LP1-7
LP2-2 LP2-2 LP2-2
LP2-2LP2-2LP2-2
LP2-2 LP2-2 LP2-2
EXISTING WIRING FOR LIGHTS
CONNECTED TO JUNCTION
BOX IN ADJACENT ROOM
LP1-7
L5
L5
INDICATES EXISTING EXIT SIGNS TO BE REMOVED. NEW
EXIT SIGNS WILL REPLACE ORIGINAL IN EXISTING
LOCATION. SEE SHEET E-3 FOR FIXTURE DETAILS. (L5)
5/
/2
5/
/2
5/
/2
J INDICATES EXISTING JUNCTION BOX ABOVE CEILING.
W2020-321-01
R .N
E
LS
O N
(TYPICAL)
S INDICATES NEW LIGHT SWITCH TO BE INSTALLED.
(TYPICAL)
"L1"
"L3"
INDICATES NEW EMERGENCY LIGHTS TO BE INSTALLED.
NEW EMERGENCY LIGHTS WILL REPLACE ORIGINAL IN
EXISTING LOCATION. SEE THIS SHEET FOR DETAILS. (L3)
L3
L5
SEE REFLECTED CEILING PLAN ON SHEET A-3 FOR EXACT
LOCATIONS WITHIN CEILING GRID. EXISTING CEILING HEIGHT IS
9'-1". NEW CEILING HEIGHT TO BE THE SAME.
E
P A
R
TM
E N
T O
F
TH
E N
A V
Y
N E
W P
O R
T, R
H O
D E
IS
LA
N D
N A
V A
L U
N D
E R
S E
A W
A R
FA
R
E C
E N
TE
R
D
IV
IS
IO
N
SHEET OF
CONTRACT NO.
NAVFAC DRAWING NO.
NUWC DRAWING NO.
SCALE:
SIZE: ANSI D
A P
P R
O V
E D
C H
E C
K E
D B
Y
D E
S
IG
N E
D B
Y
D R
A W
N B
Y
D A
TE
S A
TI
S
FA
C
TO
R
Y T
O D
A
TE
D A
TE
D A
TE
D A
TE
R E
V
IS
IO
N
S S
Y M
D E
S C
R
IP
TI
O
N D
A
TE
A P
P R
AS NOTED
21-016A
S .T
IL
LE
Y
S .T
8 11
E-2
B U
IL
D
IN
G
E
X
IS
TI
N
G / N
E W
E
LE
C
TR
IC
A
L P
LA
N
FA
C
IL
IT
IE
S
B R
A N
C H
B R
E A
K R
O O
M R
E N
O V
A
TI
O N
S
LEGEND: GENERAL NOTES
1 WORK NOTE
WORKING NOTES
INDICATES EXISTING ELECTRICAL OUTLET TO REMAIN.
CIRCUIT SHALL BE VERIFIED BEFORE WORK BEGINS.
INDICATES PANEL AND CIRCUIT NUMBER
INDICATES EXISTING EMERGENCY LIGHTS TO BE
REMOVED. NEW EMERGENCY LIGHTS WILL REPLACE
ORIGINAL IN EXISTING LOCATION. SEE THIS SHEET FOR
DETAILS. (L3)
L3
1/4"=1'-0"
5' 0' 5' 10' 15' 20'
GRAPHIC SCALE
SPECIFIC DEMOLITION NOTES1
1. CONTRACTOR SHALL VERIFY ALL DIMENSIONS IN FIELD PRIOR TO ORDERING MATERIALS.
2. UNLESS INDICATED OTHERWISE, ALL ITEMS IN BOLD ARE NEW.
3. ALL ELECTRICAL WIRING SHALL BE IN ACCORDANCE WITH ALL APPLICABLE LOCAL, STATE AND
FEDERAL REGULATIONS AND SHALL COMPLY WITH THE NEWEST EDITION OF THE NATIONAL
ELECTRICAL CODE (NEC) AND THE NATIONAL ELECTRICAL SAFETY CODE (NESC).
4. ALL NEW CONDUIT AND WIRING SHALL BE CONCEALED TO THE GREATEST EXTENT POSSIBLE
ABOVE SUSPENDED CEILING AND WITHIN NEW WALLS. ALL NEW CIRCUITS SHALL UTILIZE 3/12'S IN 3 4" EMT UNLESS INDICATED OTHERWISE. AT THE CONTRACTORS OPTION, ALL PORTIONS OF
20 AMP BRANCH CIRCUITS CONCEALED WITHIN WALLS OR ABOVE SUSPENDED CEILING MAY
UTILIZE METAL CLAD CABLE CONTAINING 3# 12'S (COLOR CODED). ALL WIRING SHALL BE
COPPER. ALL WIRING OF SIZES NO.10 AND SMALLER SHALL BE SOLID VICE STRANDED
CONSTRUCTION.
5. CONTRACTORS SHALL PROVIDE A GREEN INSULATED EQUIPMENT GROUND CONDUCTOR IN ALL
CIRCUITS AND TO ALL NON-CURRENT CARRYING METALLIC ITEMS.
6. ALL NEW PENETRATIONS SHALL BE SEALED. ALL HOLES LEFT BY REMOVALS SHALL BE
PREPARED AND PAINTED TO MATCH EXISTING ADJACENT SURFACES. ALL HOLES LEFT IN
ELECTRICAL BOXES, PANELS, COVERS,...ETC. SHALL BE PROVIDED WITH KNOCKOUT CLOSURE
PIECES.
7. ALL SWITCHES, SENSORS, DEVICES AND DEVICE PLATES,...ETC. SHALL BE WHITE IN COLOR.
EXISTING ELECTRICAL POWER PLAN
SCALE: 14" = 1'-0"
NEW ELECTRICAL POWER PLAN
SCALE: 14" = 1'-0"
PP6 (27)
PP6 (3)
PP6 (14)
PP6 (3)
PP6 (1)
INDICATES EXISTING EXIT SIGNS TO BE REMOVED. NEW
EXIT SIGNS WILL REPLACE ORIGINAL IN EXISTING
LOCATION. SEE THIS SHEET FOR DETAILS. (L5)
5/
/2
5/
/2
5/
/2
INDICATES NEW LOCATION OF PHONE CABINET. PHONE CABINET
INCLUDES PIPING GOING UP THROUGH EXISTING CEILING GRID.
CABINET TO BE ROTATED AS SHOWN ON NEW ELECTRICAL POWER
PLAN.
W2020-321-01
INDICATES NEW 20 AMP GFCI RECEPTACLE MOUNTED AT
COUTERTOP HEIGHT.
INDICATES PANEL AND CIRCUIT NUMBERPP6 (1)
EXISTING PROJECTOR AND SCREEN TO BE REMOVED AND RETURNED
TO GOVERNMENT. ASSOCIATED ELECTRICAL TO REMAIN INTACTED
DURING CONSTRUCTION.
EXISTING PHONE CABINET TO BE ROTATED. WORK TO BE DONE WITH
MINIMAL DISTURBANCE TO CABINET.
INDICATES EXSISTING QUAD BOX RECEPTACLE TO BE
REMOVED. NEW CIRCUIT TO PANEL NEEDS TO BE
INDICATED ON PANEL SCHEDULE.
INDICATES PANEL AND CIRCUIT NUMBER
PP6 (1)
R .N
E
LS
O N
INDICATES NEW RECEPTACLES TO BE INSTALLED. COUNTERTOP
RECEPTACLES TO BE 36" A.F.F.
C
GFCI
C
GFCI
COUNTER HEIGHT (36"A.F.F.)
PP6 (5) PP6 (9)
PP6 (14)
PP6 (3)
PP6 (12)
PP6 (3)
PP6 (15)
PP6
(17,18)
PP6 (5)
PP6 (27)
PP6 (3)PP6 (5) PP6 (9)
PP6 (3)
PP6 (5)
PP6 (3)
C
GFCI
PP6 (3)
C
GFCI
PP6 (12)
PP6 (14)
5 INDICATES NEW RECEPTACLES TO BE INSTALLED. RECEPTACLES
TO BE 18" A.F.F.
INDICATES EXISTING CEILING MOUNTED RECEPTACLE TO
BE REMOVED.
PP6 (15)
S
EXISTING
LIGHT SWITCH
TO REMAIN
S
E
P A
R
TM
E N
T O
F
TH
E N
A V
Y
N E
W P
O R
T, R
H O
D E
IS
LA
N D
N A
V A
L U
N D
E R
S E
A W
A R
FA
R
E C
E N
TE
R
D
IV
IS
IO
N
SHEET OF
CONTRACT NO.
NAVFAC DRAWING NO.
NUWC DRAWING NO.
SCALE:
SIZE: ANSI D
A P
P R
O V
E D
C H
E C
K E
D B
Y
D E
S
IG
N E
D B
Y
D R
A W
N B
Y
D A
TE
S A
TI
S
FA
C
TO
R
Y T
O D
A
TE
D A
TE
D A
TE
D A
TE
R E
V
IS
IO
N
S S
Y M
D E
S C
R
IP
TI
O
N D
A
TE
A P
P R
AS NOTED
21-016A
S .T
IL
LE
Y
S .T
9 11
E-3
B U
IL
D
IN
G
LI
G H
TI
N
G D
E
TA
IL
S
FA
C
IL
IT
IE
S
B R
A N
C H
B R
E A
K R
O O
M R
E N
O V
A
TI
O N
S
5/
/2
5/
/2
5/
/2
DIRECT/INDIRECT LED TROFFER
NL-1LIGHTING PLATE:
EMERGENCY LIGHT FIXTURE
LIGHTING PLATE:
L1
L3
LUMINAIRE REQUIREMENTS:
1. UNIT SHALL BE CONSTRUCTED OF 20 GAUGE STEEL WITH AN
OFF WHITE BAKED ENAMEL FINISH WITH REMOVABLE FRONT
COVER. CONFORM TO UL 924 AND NFPA 101.
2. THE UNIT SHALL BE DUAL RATED FOR USE ON EITHER 120 OR
277 VOLT ALTERNATING CURRENT POWER SUPPLIES.
FOLLOWING A SUSTAINED LOSS OF THE NORMAL POWER
SUPPLY. THE UNIT SHALL BE CAPABLE OF AUTOMATICALLY
AND INSTANTANEOUSLY ILLUMINATING THE 6-VOLT LIGHTING
FIXTURES FOR A PERIOD OF NOT LESS THAN 90 MINUTES AT A
BATTERY VOLTAGE IN EXCESS OF 87.5 PERCENT OF THE
NOMINAL VOLTAGE RATING.
3. THE BATTERY SHALL BE LEAD CALCIUM AND DESIGNED TO BE
MAINTENANCE FREE DURING THE EXPECTED BATTERY LIFE,
AND SHALL BE WARRANTED FOR NOT LESS THAN 3 YEARS
FROM THE DATE OF THE PURCHASE OF THAT UNIT, AND
SHALL BE FIELD REPLACEABLE WITHOUT REQUIRING
REMOVAL OF OTHER COMPONENTS. PROVIDE PULSE PLUS
CHARGER CIRCUITRY, FUSED OUTPUTS, DIAGNOSTIC
INDICATOR LIGHTS, LOW VOLTAGE BATTERY DISCONNECT,
BROWNOUT PROTECTION AND BATTERY LOCKOUT WITH
AUTOMATIC BATTERY CONNECT. THE BATTERY AND CHARGER
SHALL BE CONTAINED IN A WHITE/OFF WHITE METALLIC
CABINET, UNLESS APPROVED OTHERWISE, AND SHALL BE
EQUIPPED WITH A PUSH-TO-TEST SWITCH AND A METER TO
INDICATE BATTERY VOLTAGE.
4. THE UNIT SHALL BE PRE-WIRED AND EQUIPPED WITH TWO 4
WATT L.E.D. HEADS.
5. UNIT SHALL INCLUDE SELF DIAGNOSTIC CAPABILITY TO
PERFORM A 30 SECOND TEST EVERY 30 DAYS AND A 90 MIN
TEST ANNUALLY. IF UNIT FAILS ANY TEST, AN INTERNAL
AUDIBLE ALARM WILL SOUND UNTIL ACKNOWLEDGED.
6. UNIT SHALL BE EQUIVALENT TO EMERGI-LITE LSM54-210LA-AD
SERIES.
LUMINAIRE REQUIREMENTS:
1. HOUSING - DIE-FORMED, COLD ROLLED STEEL, WITH ON-PIECE
LOWER REFLECTOR HAVING TEXTURED, HIGH REFLECTANCE,
WHITE POLYESTER POWDER-COATED FINISH. SIZE OF 2'x2'.
2. LIGHT SOURCE - UPWARD- FACING LEDS WITH DIFFUSE LENS TO
ELIMINATE DIRECT VIEW OF LIGHT SOURCE. 4000K COLOR
TEMPERATURE UON, MAXIMUM BINNING TOLERANCE OF A
4-STEP MCADAM ELLIPSE, MINIMUM EFFICACY OF 90
LUMENS/WATT, WITH A MINIMUM CRI OF 80. INITIAL LUMEN
OUTPUT OF 2900 LUMENS.
3. DRIVER - REPLACEABLE, INTEGRAL, HIGH-EFFICIENCY DRIVER
WITH MINIMUM 0.9 PF, OPERATING VOLTAGE OF 120-277V,
THERMAL MANAGEMENT, <20% TOTAL HARMONIC DISTORTION.
PROVIDE WITH A 0-10 VOLT FULLY DIMMABLE DRIVER.
4. CERTIFICATION - UL1598, DAMP LOCATION, DLC QUALIFIED,
AND ROHS COMPLIANT. COMPLIES WITH LM79, LM80 AND TM21
TESTING STANDARDS. IC RATED WHEN INDICATED.
5. MOUNTING - RECESSED IN SUSPENDED ACOUSTICAL TILE OR
HARD CEILING.
6. FIXTURE SHALL BE EQUIVALENT TO METALUX CRUZE MODEL
22CZ-LD5-29-UNV-L840-CD1-SVPD1-V. THIS IS NOT INTENDED TO
BE PROPRIETARY, OTHER MANUFACTURERS WITH EQUIVALENT
PRODUCTS ARE ACCEPTABLE.
ALL FIXTURES TO HAVE
ALL FOUR CORNERS
SECURED TO THE
STRUCTURE ABOVE
INDEPENDENT OF THE
CEILING SUSPENSION
SYSTEM (TYP)
13"
NOMINAL
NOMINAL
9"
LED EXIT SIGN
NL-63LIGHTING PLATE:
L5
LUMINAIRE REQUIREMENTS:
1. HOUSING - DIE-CAST ALUMINUM OR STEEL CONSTRUCTION,
SINGLE OR DOUBLE-FACED AS INDICATED.
2. FINISH - POWDER COAT FINISH OPTIONS INCLUDE WHITE OR
BRUSHED ALUMINUM FACE, BLACK, OR BLACK WITH BRUSHED
ALUMINUM FACE. LETTERS/CHEVRONS- MINIMUM 6" HIGH WITH
4" STROKE. RED LETTERS.
3. AS INDICATED, PROVIDE CHEVRONS AS INDICATED EITHER
LEFT, RIGHT OR BOTH DIRECTIONS AS INDICATED, CHEVRONS
PUNCHED OUT THROUGH HOUSING AS REQUIRED.
4. EMERGENCY PACK - SOLID-STATE, CONSTANT-CURRENT TYPE
BATTERY CHARGER WITH MAINTENANCE-FREE,
NICKEL-CADMIUM BATTERY, AC-ON INDICATOR LAMP AND TEST
SWITCH.
5. MOUNTING - UNIVERSAL MOUNTING KIT FOR CEILING, WALL OR
END-OF-FIXTURE MOUNTING.
6. ILLUMINATION - PROVIDED BY RED HIGH-OUTPUT LEDS INSIDE
OF FIXTURE HOUSING. PROVIDE POLYSTYRENE DIFFUSER IN
COLOR INDICATED WITH FREQUENCY-MATCHED SILKSCREEN
COATING FOR MAXIMUM LED LIGHT OUTPUT.
7. CERTIFICATION - UL LISTED AND CERTIFIED FOR DAMP
LOCATIONS, UNIT SHALL CONFORM TO UL 924, UL 1571, AND
NFPA 101.
8. PROVIDE UNIT WITH SELF DIAGNOSTICS OPTION THAT
PERFORMS SELF TESTING OF UNIT FOR 30 SECONDS EVERY 30
DAYS AND FOR 90 MINUTES ANNUALLY SO AS TO MEET NFPA
101 LIFE SAFETY CODE FOR PERIODIC TESTING. UNIT SHALL
SOUND AN INTEGRAL AUDIBLE ALARM AND ILLUMINATE A LAMP
SHOULD ANY TESTS FAIL.
9. UNIT SHALL BE EQUIVALENT TO COOPER SURE LITES SLX7SD
SERIES.
W2020-321-01
R .N
E
LS
O N
E
P A
R
TM
E N
T O
F
TH
E N
A V
Y
N E
W P
O R
T, R
H O
D E
IS
LA
N D
N A
V A
L U
N D
E R
S E
A W
A R
FA
R
E C
E N
TE
R
D
IV
IS
IO
N
SHEET OF
CONTRACT NO.
NAVFAC DRAWING NO.
NUWC DRAWING NO.
SCALE:
SIZE: ANSI D
A P
P R
O V
E D
C H
E C
K E
D B
Y
D E
S
IG
N E
D B
Y
D R
A W
N B
Y
D A
TE
S A
TI
S
FA
C
TO
R
Y T
O D
A
TE
D A
TE
D A
TE
D A
TE
R E
V
IS
IO
N
S S
Y M
D E
S C
R
IP
TI
O
N D
A
TE
A P
P R
AS NOTED
21-016A
S .T
IL
LE
Y
S .T
10 11
P-1
NEW PLUMBING PLAN
SCALE: 14" = 1'-0"
B U
IL
D
IN
G
E
X
IS
TI
N
G / N
E W
P
LU
M B
IN
G
EXISTING PLUMBING PLAN
SCALE: 14" = 1'-0"
PLUMBING NOTES:
ALL EXISTING PLUMBING FIXTURES TO BE REMOVED AND DISPOSED OF,
INCLUDING WATER FOUNTAIN. ASSOCIATED PLUMBING TO BE REUSED.
EXISTING HOT WATER TANK TO BE REMOVED AND REUSED UNERSINK IN NEW
CABINETS TO BE INSTALLED. PLUMBING TO BE MODIFIED TO NEW LOCATION
AND EXISTING ELECTRICAL SUPPLY TO BE USED.
PROVIDE A 20"x 25"x 8" DEPTH (MINIMUM) UNDER-MOUNT STAINLESS STEEL
BAR SINK WITH HOT AND COLD WATER AND GOOSE NECK STYLE FAUCET.
EXISTING PLUMBING TO BE USED IN NEW SINK INSTALLATION. EXISTING
DRAIN TO BE PLUMBED INTO NEW SINK LOCATION.
NEW SHUT OFF VALVE TO BE INSTALLED ABOVE CEILING. NEW COLD WATER
SUPPLY TO BE INSTALLED IN NEW WALL TO BE INSTALLED. EXISTING COLD
WATER SUPPLY IN CMU BLOCK WALL TO BE REMOVED.
1. GENERAL NOTES ON THIS DRAWING ARE APPLICABLE TO EACH PLUMBING DRAWING OF THIS SET. SEE EACH
DRAWING FOR SPECIFIC NOTES APPLICABLE TO THAT DRAWING.
2. OVERHEAD PIPING IN SPACES WITH CEILINGS SHALL BE CONCEALED OR IN WALLS OR CHASES UNLESS
OTHERWISE NOTED.
3. COORDINATE LOCATION AND INSTALLATION OF EQUIPMENT WITH OTHER TRADES.OFFSET PIPING AROUND
OBSTRUCTIONS AT NO ADDITIONAL COST TO THE GOVERNMENT.
4. PROVIDE UNION OR FLANGE CONNECTIONS AT EACH PIECE OF EQUIPMENT. PROVIDE SHUT-OFF VALVES AT
EACH PIECE OF EQUIPMENT AND TAKEOFFS.
5. PIPING SHALL BE SUPPORTED IN ACCORDANCE WITH THE SPECIFICATION. ADDITIONAL SUPPORTS OR HANGERS SHALL BE ADJACENT TO ELBOWS, TO PREVENT WEIGHT OF PIPING BEING PLACED ON EQUIPMENT.
6. EXISTING PIPING AND EQUIPMENT SHOWN IS BASED ON EXISTING AND FIELD OBSERVATION WITHOUT DEMOLITION. DURING DEMOLITION, ANY CLARIFICATION REQUIRED TO DETERMINE SCOPE OF WORK SHALL
BE BROUGHT TO THE ATTENTION OF THE CONTRACTING OFFICER.
7. DRAWINGS DO NOT SHOW EVERY EXISTING PIPE, CONDUIT, DUCT,... ETC. CONTRACTOR SHALL TAKE CARE TO REMOVE ONLY ITEMS REQUIRED TO BE REMOVED AND VERIFY PIPES, DUCTS,...ETC. BEFORE REMOVAL.
8. INSTALL ALL EQUIPMENT IN STRICT ACCORDANCE WITH MANUFACTURER'S WRITTEN INSTRUCTIONS.
9. PATCH ALL HOLES FROM REMOVAL OF PIPING, DUCTWORK, AND/OR EQUIPMENT TO MATCH EXISTING
ADJACENT CONSTRUCTION.
10. PROVIDE ALL MATERIALS AND EQUIPMENT AND PERFORM ALL LABOR REQUIRED TO INSTALL COMPLETE AND OPERABLE PLUMBING SYSTEMS AS INDICATED ON THE DRAWINGS, SPECIFIED AND REQUIRED BY
CODE.
11. FIELD VERIFY ALL DIMENSIONS.
12. COORDINATE WITH THE ARCHITECTURAL DRAWINGS PRIOR TO INSTALLING PLUMBING EQUIPMENT.
13. IT IS THE INTENTION OF THE DRAWINGS TO COVER ALL WORK AND MATERIAL FOR A COMPLETE FIRST CLASS INSTALLATION. ANY EQUIPMENT, TRIM HARDWARE AND/OR DEVICES USUALLY UTILIZED IN CLASS OF WORK, THOUGH NOT SPECIFICALLY MENTIONED OR SHOWN ON THE DRAWINGS, BUT WHICH MAY BE NECESSARY FOR THE SATISFACTORY COMPLETION OF WORK (AS DETERMINED BY THE CONTRACTING OFFICER) SHALL
BE FURNISHED AND INSTALLED BY THE CONTRACTOR AS PART OF HIS TOTAL WORK.
14. CONTRACTOR SHALL GUARANTEE ALL WORK FOR A PERIOD OF ONE YEAR FROM DATE OF SUBSTANTIAL
COMPLETION.
15. EXISTING PIPE AND EQUIPMENT SIZES NOTED ARE FOR THE CONVENIENCE OF THE CONTRACTOR ONLY AND ARE NOT WARRANTED TO BE CORRECT. THE CONTRACTOR SHALL FIELD VERIFY ALL EXISTING PIPE AND
EQUIPMENT SIZES AND THEIR RESPECTIVE LOCATIONS BEFORE PROCEEDING WITH ANY WORK.
16. AFTER THE PIPING IS INSULATED, PROVIDE SETON BRAND OR EQUAL FACTORY-FABRICATED PIPE LABELS, WITH DIRECTION OF FLOW ARROWS, ON THE PIPING, AT 10 FEET ON CENTER ON THE PIPING MAINS AND 5 FEET ON CENTER ON THE BRANCH RUNOUTS FROM MAINS. FOLLOW COLOR CODING OF ASME A13.1.
17. MAKE PROPER PIPING CONNECTIONS TO ALL FIXTURES AND EQUIPMENT EVEN THOUGH ALL BRANCH
MAINS, ELBOWS AND CONNECTIONS ARE NOT SHOWN.
18. ALL PIPING SHALL BE LOCATED AND DETERMINED WHERE TO BE RUN TO AVOID CONFLICT WITH OTHER
TRADES.
19. ALL PLUMBING VENTS WITHIN A 10'-0" RADIUS OF EXHAUST VENTS SHALL BE EXTENDED TO HEIGHT OF 2'-0"
ABOVE EXHAUST VENT CROWN.
20. ALL HOT AND COLD WATER PIPING INDICATED TO BE RUN ABOVE FINISHED CEILINGS OR IN EXTERIOR WALLS SHALL BE INSTALLED ON THE CONDITIONED SPACE SIDE OF THE BUILDING INSULATION.
GENERAL NOTES:
FA
C
IL
IT
IE
S
B R
A N
C H
B R
E A
K R
O O
M R
E N
O V
A
TI
O N
S
5/
/2
5/
/2
5/
/2
2" COLD WATER
PIPE LOCATED
ABOVE CEILING
W2020-321-01
R .N
E
LS
O N
PLUMBING LEGEND:
INDICATES EXISTING COLD WATER PIPING.
INDICATES NEW COLD WATER PIPING.
INDICATES EXISTING SHUT VALVES TO REMAIN.
INDICATES EXISTING SANITARY PIPES TO REMAIN.
INDICATES CONNECTION POINT BETWEEN NEW AND
EXISTING SUPPLY LINES.
EXISTING VENT
PIPE TO REMAIN
2" COLD WATER
PIPE LOCATED
ABOVE CEILING
EXISTING VENT
PIPE TO REMAIN
VENT PIPE IN
CMU WALL
COLD WATER
SUPPLY IN
CMU WALL
SANITARY
WASTE PIPE IN
CMU WALL
EXISTING HOT
WATER TANK
UNDER SINK
IN CABINET
SINK DRAIN
HOT WATER
TO EXISTING
SINK
WATER SUPPLY TO EXISTING SINK
E
P A
R
TM
E N
T O
F
TH
E N
A V
Y
N E
W P
O R
T, R
H O
D E
IS
LA
N D
N A
V A
L U
N D
E R
S E
A W
A R
FA
R
E C
E N
TE
R
D
IV
IS
IO
N
SHEET OF
CONTRACT NO.
NAVFAC DRAWING NO.
NUWC DRAWING NO.
SCALE:
SIZE: ANSI D
A P
P R
O V
E D
C H
E C
K E
D B
Y
D E
S
IG
N E
D B
Y
D R
A W
N B
Y
D A
TE
S A
TI
S
FA
C
TO
R
Y T
O D
A
TE
D A
TE
D A
TE
D A
TE
R E
V
IS
IO
N
S S
Y M
D E
S C
R
IP
TI
O
N D
A
TE
A P
P R
AS NOTED
21-016A
S .T
IL
LE
Y
S .T
11 11
FP-1
NEW FIRE PROTECTION PLAN
SCALE: 14" = 1'-0"
B U
IL
D
IN
G
E
X
IS
TI
N
G / N
E W
F
IR
E P
R O
TE
C
TI
O
N P
LA
N
EXISTING FIRE PROTECTION PLAN
SCALE: 14" = 1'-0"
TYPICAL PENDANT SPRINKLER
SCALE: NTS
NOTES: ADJUST SPRINKLER DROPS AS NECESSARY TO CLEAR OBSTRUCTIONS SUCH AS
THE CEILING "T" BAR SUSPENSION SYSTEM, LIGHTING FIXTURES,ETC. PROVIDE A PIPE
HANGER IF THE HORIZONTAL OFFSET LENGTH EXCEEDS 24".
1" BLACK STEEL SCHEDULE
40 PIPING, TYP.
PROVIDE NEW CHROME PENDANT
SPRINKLER HEAD (155 DEGREE F)
1" x 1/2" PIPE REDUCING COUPLING
FIRE PROTECTION NOTES
1. EXISTING SPRINKLER HEADS TO BE REMOVED (DARK DASHED).
2. NEW PENDANT SPRINKLER HEADS TO BE INSTALLED (BOLD).
SEE DETAIL ON THIS SHEET. NEW PIPING TO BE INSTALLED
FROM EXISTING PENDANT LOCATION.
LEGEND:
INDICATES NEW SPRINKLER HEADS (BOLD)
INDICATES EXISTING SPRINKLER PIPING (GRAY)
INDICATES NEW SPRINKLER PIPING (BOLD)
INDICATES EXISTING SPRINKLER HEADS TO BE MOVED (DASHED BOLD)
PROVIDE LENGTH TO SUIT
PROVIDE
LENGTH TO SUIT
1 INDICATES WORK NOTE
FA
C
IL
IT
IE
S
B R
A N
C H
EXISTING 2" BRANCH PIPE
B R
E A
K R
O O
M R
E N
O V
A
TI
O N
S
5/
/2
5/
/2
5/
/2
W2020-321-01
R .N
E
LS
O N
(TYPICAL)
(TYPICAL)
171 INDICATES ROOM NUMBER
INDICATES EXISTING SPRINKLER PIPING TO BE REMOVED (BOLD)
| Sheets and Views |
| BLDG 1170 Breakroom Renovations-T-1 |
| BLDG 1170 Breakroom Renovations-D-1 |
| BLDG 1170 Breakroom Renovations-A-1 |
| BLDG 1170 Breakroom Renovations-A-2 |
| BLDG 1170 Breakroom Renovations-A-3 |
| BLDG 1170 Breakroom Renovations-M-1 |
| BLDG 1170 Breakroom Renovations-E-1 |
| BLDG 1170 Breakroom Renovations-E-2 |
| BLDG 1170 Breakroom Renovations-E-3 |
| BLDG 1170 Breakroom Renovations-P-1 |
| BLDG 1170 Breakroom Renovations-FP-1 |
File details come from the government source that posted it. Updated .