View the file

Other files

Show all 14

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

WORK REQ. NO.

D E

P A

R

TM

E N

T O

F

TH

E N

A V

Y

N E

W P

O R

T, R

H O

D E

IS

LA

N D

FA

C

IL

IT

IE

S

B R

A N

C H

N A

V A

L U

N D

E R

S E

A W

A R

FA

R

E C

E N

TE

R

D

IV

IS

IO

N

SHEET OF

CONTRACT NO.

NAVFAC DRAWING NO.

NUWC DRAWING NO.

SCALE:

SIZE: ANSI D

A P

P R

O V

E D

C H

E C

K E

D B

Y

D E

S

IG

N E

D B

Y

D R

A W

N B

Y

D A

TE

S A

TI

S

FA

C

TO

R

Y T

O D

A

TE

D A

TE

D A

TE

D A

TE

R E

V

IS

IO

N

S S

Y M

D E

S C

R

IP

TI

O

N D

A

TE

A P

P R

AS NOTED

B U

IL

D

IN

G

N

U W

C D

IV

N

W P

T

B R

E A

K R

O O

M R

E

FU

R B

IS

H

M E

N T

TI

TL

E S

H E

E T

21-016A

S .T

IL

LE

Y

S .T

1 11

T-1

SCALE: NTS

1. NEW CONSTRUCTION IS SHOWN IN DARK BLACK. ITEMS TO BE REMOVED ARE SHOWN AS DASHED LINES. EXISTING FEATURES AND ITEMS TO REMAIN ARE

SHOWN IN GRAY.

2. THE CONTRACTOR SHALL CONFORM TO ALL STATE, NATIONAL AND OTHER CODES AND ORDINANCES WHICH APPLY TO THIS PROJECT.

3. THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL PERMITS WHICH ARE REQUIRED FOR THE SATISFACTORY COMPLETION OF THE WORK.

4. THE CONTRACTOR SHALL PROVIDE TO THE GOVERNMENT ALL SAFETY DATA SHEETS (SDS) IN ACCORDANCE WITH NUWC HAZARDOUS MATERIAL CONTROL (HAZCON) PROGRAM FOR ALL HAZARDOUS MATERIALS. REVIEW AND APPROVAL IS REQUIRED PRIOR TO BRINGING MATERIAL ON SITE. TYPICAL ITEMS REQUIRING SDS SHEETS INCLUDE PAINTS, ADHESIVES, SEALANTS, CAULKING, JOINT COMPOUND, ETC.

5. THE CONTRACTOR SHALL IDENTIFY AND FIELD VERIFY POINTS OF CONNECTION WHERE EXISTING AND NEW CONSTRUCTION MEET AND REPORT ANY DISCREPANCIES TO THE CONTRACTING OFFICER. THE CONTRACTOR SHALL PROCEED WITH THE WORK ONLY AFTER THE DISCREPANCIES HAVE BEEN

RESOLVED BY THE GOVERNMENT.

6. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS IN THE FIELD PRIOR TO ORDERING MATERIAL.

7. THE CONTRACTOR SHALL GAIN GOVERNMENT APPROVAL REGARDING COLORS RELATED TO THIS PROJECT. ALL PAINT SHALL BE ZERO V.O.C. TYPE. A COLOR

BOARD SHALL BE SUBMITTED FOR REVIEW AND APPROVAL.

8. THE CONTRACTOR SHALL PROVIDE ALL NECESSARY COMPONENTS AND PERFORM ALL WORK RELATED TO THIS PROJECT UNLESS OTHERWISE NOTED.

9. THE CONTRACTOR SHALL REMOVE AND RE-INSTALL ALL WALL AND CEILING MOUNTED ITEMS (SIGNAGE, ELECTRICAL DEVICES, ETC.). UNLESS ITEM IS

SCHEDULED FOR DEMOLITION. IF LEFT IN PLACE, PROTECT ITEMS DURING WORK.

10. THE CONTRACTOR SHALL REPAIR OR REPLACE ANY EQUIPMENT OR SURFACE TO REMAIN THAT IS DAMAGED BY HIS/HER OPERATIONS, AS APPROVED BY THE CONTRACTING OFFICER AT NO ADDITIONAL COST TO THE GOVERNMENT. DAMAGED SURFACES SHALL MATCH EXISTING FINISHES AND COLOR.

11. THE CONTRACTOR SHALL DISPOSE OF AND/OR RECYCLE CONSTRUCTION DEBRIS FROM THE PROJECT SITE IN A MANNER APPROVED BY STATE AND FEDERAL

REGULATIONS.

12. THE CONTRACTOR SHALL LEAVE THE CONSTRUCTION SITE IN A NEAT AND CLEAN MANNER AT THE END OF EACH WORKING DAY.

13. THE BUILDING WILL REMAIN OCCUPIED AND IN OPERATION DURING THE WORK. PORTIONS OF THE BUILDING OUTSIDE THE WORK AREA WILL REMAIN

OCCUPIED AND SECURED. CONTRACTOR SHALL PROTECT THESE OCCUPANTS FROM DUST, NOISE, AND FUMES DURING EXECUTION OF THE WORK. THE

WORK AREA WILL REMAIN CLOSED DURING CONSTRUTION.

INDEX OF DRAWINGS

GENERAL NOTES:

WORK AREA: BUILDING 1170 EXISTING PLAN

LOCATION MAP

C U

N N

IN

G

H A

M

BUSHNELL

E

FE

N S

E H

IG

H

W A

Y

CUNNINGHAM

LAY STREET

S T

R E

E T

FULTON

P O

R T

E R

S T

R E

E T

H U N

T STR

EET

LEAVITT STR

EET

ERICSON

C U N N

IN

G H

AM

P O

R T E R

S T R

E E T

STREET

LAY STREET

STR

EET

F U

L T O

N

STREET

STREET

S T R

E E

T

C U

N N

IN

G

H A

M S

T R

E E T

D E

F E

N S

E H

IG

H

W A

Y

C H

A S

E S

L A

N E

S T R

E E

T

FLEET ACCESS ROAD

BOOM STREET

N O

R T H

H O

W E L L S

T R

E E T

FU

LTO

N

S T R

E E T

S T

R E

E T

W A N U M

E T O N O M Y

G O L F & C O U N T R Y C L U B

PIER N0. 1

N A

R R

A G

A N

S E

T T

B A

Y

PIER N0. 2

WARFARE CENTER

NAVAL UNDERSEA

FACILITIES

BUILDING

GATE 23

TO ROUTE 114

GATE 32

THE SCOPE OF THIS RENOVATION PROJECT INCLUDES WORK TO BE

PERFORMED IN THE CURRENT ROOM 171 BREAK ROOM. WORK INCLUDES

PAINTING, REMOVING EXISTING ASBESTOS CONTAINING FLOOR TILES AND

MASTIC, NEW FLOORING, NEW CABINETS, NEW CEILING GRID AND CEILING

TILES, ELECTRICAL UPGRADES, NEW LIGHTING, NEW PLUMBING, AS WELL AS,

ALL OTHER INCIDENTAL WORK FOR A COMPLETE AND USABLE FACILITY.

SCOPE OF WORK:

SHEET

NUMBER

NUWCDIVNPT

DWG. NO. DWG. NUMBER

DISCIPLINE

DRAWING TITLE

1 OF 11 TITLE SHEETT-1

18-055A

D-1 ARCHITECTURAL DEMOLITION PLAN

A-1

A-2

A-3

NEW FLOOR PLAN

FIXTURE/ ACCESSORY PLAN

BUILDING 1170

ROOM 171 BREAK ROOM RENOVATIONS

NAVAL UNDERSEA WARFARE CENTER

NEWPORT, RI FACILITIES BRANCH

INDEX OF DRAWINGS

PROJECT SITE

BUILDING 1170

18-055A

18-055A

18-055A

E-1 EXISTING/ NEW LIGHTING PLAN18-055A

P-118-055A EXISTING/ NEW PLUMBING

FP-118-055A EXISTING/ NEW FIRE PROTECTION

WORK AREA

18-055A EXISTING/ NEW CEILING PLAN

BUILDING LOCATION

5/

/2

5/

/2

5/

/2

P O

R T

E R

S T

R E

E T C U N N

IN

G H

AM

BLDG. 1170

WORK

AREA

M-1 EXISTING/ NEW HVAC PLAN18-055A6 OF 11

E-2 EXISTING/ NEW ELECTRICAL PLAN18-055A8 OF 11

E-3 LIGHTING DETAILS18-055A9 OF 11

W2020-321-01

GATE 17

R .N

E

LS

O N

AutoCAD SHX Text

SEAL

AutoCAD SHX Text

STONE

AutoCAD SHX Text

BREAKWATER

AutoCAD SHX Text

CREEK

AutoCAD SHX Text

STOP

AutoCAD SHX Text

STOP

AutoCAD SHX Text

STOP

AutoCAD SHX Text

STOP

AutoCAD SHX Text

STOP

AutoCAD SHX Text

STOP

AutoCAD SHX Text

STOP

AutoCAD SHX Text

STOP

AutoCAD SHX Text

STOP

AutoCAD SHX Text

PROPANE

AutoCAD SHX Text

TANKS

AutoCAD SHX Text

BUSHNELL STREET

AutoCAD SHX Text

BUSHNELL STREET

AutoCAD SHX Text

BASIN "C"

AutoCAD SHX Text

BASIN "B"

AutoCAD SHX Text

BASIN "A"

AutoCAD SHX Text

HEADQUARTER STREET

AutoCAD SHX Text

RAILROAD RIGHT OF WAY

AutoCAD SHX Text

CHILLER

AutoCAD SHX Text

CHILLER

AutoCAD SHX Text N

AutoCAD SHX Text N

AutoCAD SHX Text N

AutoCAD SHX Text

STOP

AutoCAD SHX Text

STOP

AutoCAD SHX Text

STOP

AutoCAD SHX Text

STOP

E

P A

R

TM

E N

T O

F

TH

E N

A V

Y

N E

W P

O R

T, R

H O

D E

IS

LA

N D

FA

C

IL

IT

IE

S

B R

A N

C H

N A

V A

L U

N D

E R

S E

A W

A R

FA

R

E C

E N

TE

R

D

IV

IS

IO

N

SHEET OF

CONTRACT NO.

NAVFAC DRAWING NO.

NUWC DRAWING NO.

SCALE:

SIZE: ANSI D

A P

P R

O V

E D

C H

E C

K E

D B

Y

D E

S

IG

N E

D B

Y

D R

A W

N B

Y

D A

TE

S A

TI

S

FA

C

TO

R

Y T

O D

A

TE

D A

TE

D A

TE

D A

TE

R E

V

IS

IO

N

S S

Y M

D E

S C

R

IP

TI

O

N D

A

TE

A P

P R

AS NOTED

B U

IL

D

IN

G

A

R C

H

IT

E C

TU

R

A L

D E

M O

LI

TI

O N

P

LA

N

21-016A

S .T

IL

LE

Y

S .T

2 11

D-1

EXISTING DEMOLITION PLAN

SCALE: 14" = 1'-0"

LEGEND:

SPECIFIC DEMOLITION NOTES

DENOTES PHOTO NUMBER AND LOCATION TAKEN1

APPROX. 850 SQ.FT. OF ASBESTOS FLOOR TILE AND

MASTIC TO BE REMOVED.

EXISTING FLOORING TO BE REMOVED

SCALE: 14" = 1'-0"

B R

E A

K R

O O

M R

E N

O V

A

TI

O N

S

ASBESTOS DEMOLITION NOTE:

EXISTING VINYL FLOOR TILE AND MASTIC CONTAIN ASBESTOS

AND SHALL TO BE REMOVED AND DISPOSED OF PROPERLY

USING PROPER STATE AND FEDERAL ABATEMENT

PROCEDURES. ANY ITEMS NOT PART OF THIS PROJECT AND

REMAINING GOVERNMENT PROPERTY REQUIRING TO BE

REMOVED BEFORE ASBESTOS ABATEMENT WILL BE REMOVED

BY THE GOVERNMENT.

DEMOLITION NOTES:

EXISTING CABINETS TO BE REMOVED AND DISPOSED OF PROPERLY.

SINK IN COUNTERTOPS TO BE REMOVED AND DISPOSED OF PROPERLY.

ALL ASSOCIATED PLUMBING TO REMAIN FOR RECONNECTION TO NEW

KITCHEN CABINET AND SINK.

CEILING GRID AND CEILING TILE TO BE REMOVED AND DISPOSED OF

PROPERLY (DASHED). ALL LIGHTING FIXTURES TO BE REMOVED AND

DISPOSED OF PROPERLY (DASHED). ALL EMERGENCY LIGHTS,

SPRINKLER HEADS, HVAC REGISTERS TO BE REMOVED. ALL ITEMS WILL

BE REUSED UNLESS OTHERWISE NOTED IN DRAWINGS. SEE SHEET A-3.

PROVIDE PROPER SUPPORT AS NECESSARY WHILE CEILING

SUSPENSION SYSTEM IS REPLACED.

EXISTING FLOOR TILE AND MASTIC TO BE REMOVED. FLOOR TILE AND

MASTIC CONTAIN ASBESTOS AND SHOULD BE REMOVED AND DISPOSED

OF BY A LICENSED ASBESTOS REMEDIATION COMPANY. ASBESTOS

REMEDIATION COMPANY SHALL FOLLOW GOVERNMENT AND STATE

LAWS FOR REMEDIATION AND DISPOSAL OF MATERIALS. THIRD PARTY

AIR QUALITY CONTROL COMPANY SHALL BE USED TO CLEAR THE AREA

BEFORE WORK CAN PROCEED. REFER TO SPECIFICATION SECTION

02 82 00 ASBESTOS REMEDIATION.

ELECTRICAL OUTLETS ON WALL WHERE EXISTING CABINETS ARE

LOCATED SHALL BE REMOVED. CIRCUITS TO REMAIN IN USE WHILE

CONSTRUCTION IS GOING ON. THESE CIRCUITS WILL BE REUSED AFTER

NEW WALL IS INSTALLED FOR NEW CABINETS INSTALLATION. SEE

SHEET E-2.

EXISTING WATER FOUNTAIN TO BE REMOVED AND DISPOSED OF

PROPERLY.

REMOVE AND RETURN TO GOVERNMENT EXISTING CEILING MOUNTED

PROJECTOR AND ASSOCIATED CEILING MOUNTED SCREEN.

ASSOCIATED ELECTRICAL TO BE RUN BACK TO NEAREST JUNCTION

BOX. CIRCUIT TO REMAIN INTACT. SEE SHEET E-1 FOR DETAILS

5/

/2

5/

/2

5/

/2

1 PHOTO 1

2 PHOTO 2

EXISTING PHONE TOWER TO

REMAIN. PHONE TOWER TO

BE ROTATED TO FIT INTO

NEW MECHANICAL CLOSET.

SEE SHEET E-2.

EXISTING CEILING

MOUNTED

REGISTERS AND

DIFFUSERS TO BE

REMOVED AND

REPLACED AFTER

NEW CEILING GRID

IS INSTALLED.

(TYP.8)

EXISTING CABINETS (WATER FOUNTAIN)

TO BE REMOVED AND DISPOSED OF

PROPERLY. ALL ASSOCIATED PLUMBING

TO REMAIN. SOAP DISPENSER AND

PAPER TOWEL DISPENSER TO BE

REMOVED AND REINSTALLED.

EXISTING REFRIGERATORS TO

BE MOVED OUT OF AREA (BY

GOVERNMENT) TEMPORARILY

UNTIL PROJECT IS COMPLETE.

SEE REFLECTED CEILING PLAN

A-3.

EXISTING FLOOR TILE AND

MASTIC TO BE REMOVED

AND DISPOSED OF

PROPERLY. FLOOR TILE

AND MASTIC CONTAIN

ASBESTOS.

W2020-321-01

EXISTING LIGHTS TO BE REMOVED AND DISPOSED OF

PROPERLY. CIRCUIT TO REMAIN INTACT DURING

REMODEL. SEE SHEET E-1 FOR DETAILS.

EXISTING HVAC SUPPLY REGISTER TO BE REMOVED

AND DISPOSED OF PROPERLY. SEE SHEET M-1 FOR

DETAILS.

EXISTING HVAC RETURN REGISTER TO BE REMOVED

AND DISPOSED OF PROPERLY. SEE SHEET M-1 FOR

DETAILS.

EXISTING CONCRETE/CMU BLOCK WALL.

28'-511 16"

30'-2"

R .N

E

LS

O N

EXISTING CMU

BLOCK WALL

SEAL

E

P A

R

TM

E N

T O

F

TH

E N

A V

Y

N E

W P

O R

T, R

H O

D E

IS

LA

N D

N A

V A

L U

N D

E R

S E

A W

A R

FA

R

E C

E N

TE

R

D

IV

IS

IO

N

SHEET OF

CONTRACT NO.

NAVFAC DRAWING NO.

NUWC DRAWING NO.

SCALE:

SIZE: ANSI D

A P

P R

O V

E D

C H

E C

K E

D B

Y

D E

S

IG

N E

D B

Y

D R

A W

N B

Y

D A

TE

S A

TI

S

FA

C

TO

R

Y T

O D

A

TE

D A

TE

D A

TE

D A

TE

R E

V

IS

IO

N

S S

Y M

D E

S C

R

IP

TI

O

N D

A

TE

A P

P R

AS NOTED

21-016A

S .T

IL

LE

Y

S .T

3 11

A-1

B U

IL

D

IN

G

N

E W

F

LO

O R

P

LA

N

NEW WALL TO BE INSTALLED USING METAL STUDS AND 5 8" GWB. WALL TO BE PREPPED FOR TWO (2) COATS OF PRIMER AND TWO (2) COATS OF PAINT (GRAY SCREEN #SW7071). SEE THIS SHEET FOR WALL SECTION DETAIL

(WALL SECTION "A").

NEW WALL TO BE INSTALLED USING METAL STUDS AND 5 8" GWB. WALL TO BE PREPPED FOR TWO (2) COATS OF PRIMER AND TWO (2) COATS OF PAINT (GRAY SCREEN #SW7071). SEE THIS SHEET FOR WALL SECTION DETAIL

(WALL SECTION "B").

NEW CEILING GRID AND TILES TO BE INSTALLED (SHEET A-3). ADD NEW LIGHTING FIXTURES AS SHOWN ON

SHEET E-2.

NEW LIGHTS ARE TO BE 2x2 LED, AND UTILIZE EXISTING CIRCUITS FROM EXISTING POWER PANEL.

SEE SHEET A-3 AND E-1 FOR LIGHTING LAYOUT.

NEW CABINETS TO BE INSTALLED. SEE NEW CABINET ELEVATION ON SHEET A-2.

NEW DOOR TO BE INSTALLED IN NEW WALL . SEE DOOR DETAILS ON SHEET A-2.

PROVIDE A 20"x 25"x 8" DEPTH (MINIMUM) UNDER-MOUNT STAINLESS STEEL BAR SINK WITH HOT AND COLD

WATER AND GOOSE NECK STYLE FAUCET.

CONSTRUCTION NOTES:

LEGEND:

1 INDICATES WORK NOTES

INDICATES WALL DETAIL (SEE WALL DETAILS ON THIS

SHEET)

1/4"=1'-0"

5' 0' 5' 10' 15' 20'

FA

C

IL

IT

IE

S

B R

A N

C H

A A 4

INDICATES DETAIL SECTION OR ELEVATION

INDICATES ELEVATION NUMBER OR SECTION LETTER

INDICATES SHEET

GRAPHIC SCALE

W2020-321-01

NEW FLOOR PLAN

SCALE: 14" = 1'-0"

NEW FLOOR PLAN W/ DIMENSIONS

SCALE: 14" = 1'-0"

B R

E A

K R

O O

M R

E N

O V

A

TI

O N

S

1/2"=1'-0" 1'

0' 5' 10'6' 7' 8' 9'4'3'2'1'

REF.

REF.

171 171

7'-7"

8'

12'

7'-101 2"

10'-31 2"

FLOOR TILE (SEE

FINISH SHEET A-3)

SLAB ON GRADE

2x4 METAL STUDS 16" O.C.

8" FIRE RATED

GWB BOARD.

NEW SUSPENDED

CEILING 9'-0" A.F.F.

NEW WALL SECTION

SCALE: 12" = 1'-0"

A

9'-55 8"

MECH.

ROOM

MECH.

ROOM

FLOOR TILE (SEE

FINISH SHEET A-3)

SLAB ON GRADE

2x6 METAL STUDS

16" O.C. FOR

PLUMBING AND

ELECTRICAL

NEW SUSPENDED

CEILING 9'-0" A.F.F.

NEW WALL SECTION

SCALE: 12" = 1'-0"

2" AIR GAP BETWEEN

EXISTING WALL AND

NEW STUD WALL

REF.

REF.

3.

4.

4'-11 4"

NEW SUSPENDED

CEILING 9'-0" A.F.F.

5/

/2

5/

/2

5/

/2

NEW LOCATION

OF PAPER TOWEL

DISPENSER

EXISTING CMU

BLOCK WALL

INDICATES NEW WALL TO BE INSTALLED. SEE WALL

SECTIONS ON THIS SHEET.

101 INDICATES NEW DOOR TO BE INSTALLED. SEE

SHEET A-2 FOR DETAILS.

EXISTING CONCRETE/CMU BLOCK WALL.

WALL TO BE 12" ABOVE

SUSPENDED CEILING. WALL

TO BE BRACED TO ROOF

DECK

WALL TO BE 12" ABOVE

SUSPENDED CEILING. WALL

TO BE BRACED TO ROOF

DECK

8" FIRE RATED

GWB BOARD.

8" FIRE RATED

GWB BOARD.

B

A

A

A

B

MECHANICAL

ROOM SIDE

R .N

E

LS

O N

PROVIDE WOOD

BLOCKING WHERE

NEEDED FOR CABINET

INSTALLATION.

A 2 2

ADD MINERAL

WOOL INSULATION

FOR SOUND.

STUD WALL TO SIT ON

TOP OF FINISHED FLOOR

STUD WALL TO SIT ON

TOP OF FINISHED FLOOR

2'-6"EXISTING CMU

BLOCK WALL

E

P A

R

TM

E N

T O

F

TH

E N

A V

Y

N E

W P

O R

T, R

H O

D E

IS

LA

N D

N A

V A

L U

N D

E R

S E

A W

A R

FA

R

E C

E N

TE

R

D

IV

IS

IO

N

SHEET OF

CONTRACT NO.

NAVFAC DRAWING NO.

NUWC DRAWING NO.

SCALE:

SIZE: ANSI D

A P

P R

O V

E D

C H

E C

K E

D B

Y

D E

S

IG

N E

D B

Y

D R

A W

N B

Y

D A

TE

S A

TI

S

FA

C

TO

R

Y T

O D

A

TE

D A

TE

D A

TE

D A

TE

R E

V

IS

IO

N

S S

Y M

D E

S C

R

IP

TI

O

N D

A

TE

A P

P R

AS NOTED

21-016A

S .T

IL

LE

Y

S .T

4 11

A-2

B U

IL

D

IN

G

FI

X

TU

R E

/ A C

C E

S S

O R

Y P

LA

N

FA

C

IL

IT

IE

S

B R

A N

C H

NEW FLOORING PLAN

SCALE: 14" = 1'-0"

WALL COLOR IN LUNCHROOM. WALL COLOR

FOR ROOM 171 TO BE SHERWIN WILLIAMS

#SW7071 GRAY SCREEN WITH EGGSHELL

FINISH. TRIM PAINT TO BE FLAT BLACK.

PAINT

B R

E A

K R

O O

M R

E N

O V

A

TI

O N

S

ARMSTRONG VINYL PLANK FLOORING-

CASTLE LUXURY VINYL TILE-

COLOR: SILVER MINE 7.2in Wide x 48in Long

APPROX. 1000 SQ.FT. W/ 20% OVERAGE.

BASE MOLDING TO BE: JOHNSONITE RECESS

VINYL WALL BASE, RWDC-63 "BURNT UMBER"

FLOORING

CABINETS TO BEMANUFACTORED BY

"CLASSIC". COLOR TO BE DARTMOUTH

HONEY. SOFT CLOSE DOORS AND DRAWERS

TO BE INCLUDED.

CABINET HARDWARE: SATIN STEEL KNOBS

FOR PULL DRAWERS AND HANDLES FOR

DOORS

CABINETS

B36 B36 B36 B36

U3630 U3615

COUNTER TOP TO BE GRANITE WITH 4" BACK

SPLASH. COLOR TO BE BLUE PEARL GRANITE.COUNTER TOP

3' 3' 3' 3' 3'

BORED LOCKSET SEE

HARDWARE SCHEDULE

FOR HARDWARE

REQUIREMENTS

F-1

16 GAUGE STEEL FRAME

(KNOCK DOWN TYPE)

SOLID CORE

WOOD DOOR

FRAME

SIZE (inches)

W

ID

T H

H E

IG

H

T

T H

IC

K

DOOR

T Y

P E

M A

T

M A

T

REMARKS

H E

A D

T Y

P E

T H

R E

S

J A

M B

DETAILS

H A

R D

W A

R E

L A

B E

L F

IR

E R

A T

IN

G

S E

T N

O

D O

O R

N O

F R

O M

T H

IS

S

H E

E T

DOOR AND FRAME SCHEDULE NOTE:

ALL HARDWARE SHALL BE SATIN STAINLESS STEEL FINISH, GRADE 1

36 84 1 3/4 W A STEEL F1 -1 1 - 101

HW-101

· 1 12 PAIR HINGES - ANSI/BHMA A156.1 4 12"x 4 12" TYPE A8111

HEAVY DUTY

· 1 BORED LOCKSET - ANSI/BHMA A156.2 SERIES 4000, GRADE 2,

FUNCTION F86, STOREROOM FUNCTION PROVIDE

INTERCHANGEABLE CYLINDER TO ACCEPT 6 PIN CORE

MANUFACTURED BY "BEST" (PREFER STANLEY/BEST 7KC SERIES)

· 3 EA - DOOR SILENCERS

· 1 BORED LOCKSET FOR DEADBOLT

F-1

DOOR HARDWARE

3'-4"

7'-2"

2" 2"

5/

/2

5/

/2

5/

/2

6'-111 2"

2'-10"

2'-101 2"

1'-3"

1'-6"

15'

NEW CABINET ELEVATION

SCALE: 12" = 1'-0"

W2020-321-01

NEW DOOR AND FINISH PLAN

SCALE: 14" = 1'-0"

A 2 2

JAMB 1 HEADER 1

ANODIZED ALUMINUM FRAME:

· FRAME TO BE 16 GAUGE

· PROVIDE THE PROPER ANCHORS FOR ADJOINING

STEEL STUD CONSTRUCTION

· PREP AND REINFORCE FRAME AS NECESSARY

FOR THE SPECIFIED HARDWARE

FRAME DETAILS

NTS

U3615 U3630

BORED LOCKSET

FOR DEADBOLT

TYPE "A"

NOTE: AFTER REMOVAL OF ASBESTOS

CONTAINING FLOOR AND MASTIC, THE

CONTRACTOR SHALL PREP AND LEVEL

FLOOR AS NECESSARYTO INSTALL NEW

FLOORING IN ACCORDANCE WITH

MANUFACTER'S INSTRUCTIONS

R .N

E

LS

O N

E

P A

R

TM

E N

T O

F

TH

E N

A V

Y

N E

W P

O R

T, R

H O

D E

IS

LA

N D

N A

V A

L U

N D

E R

S E

A W

A R

FA

R

E C

E N

TE

R

D

IV

IS

IO

N

SHEET OF

CONTRACT NO.

NAVFAC DRAWING NO.

NUWC DRAWING NO.

SCALE:

SIZE: ANSI D

A P

P R

O V

E D

C H

E C

K E

D B

Y

D E

S

IG

N E

D B

Y

D R

A W

N B

Y

D A

TE

S A

TI

S

FA

C

TO

R

Y T

O D

A

TE

D A

TE

D A

TE

D A

TE

R E

V

IS

IO

N

S S

Y M

D E

S C

R

IP

TI

O

N D

A

TE

A P

P R

AS NOTED

21-016A

S .T

IL

LE

Y

S .T

5 11

A-3

B U

IL

D

IN

G

E

X

IS

TI

N

G / N

E W

C E

IL

IN

G P

LA

N

NEW REFELECTED CEILING PLAN

SCALE: 14" = 1'-0"

LEGEND:GENERAL NOTES

L1

1 WORK NOTE.

NEW 2x2 CEILING GRID, INTERMEDIATE DUTY; 15

16" WIDE;

PROVIDE WIRE SUPPORTS AT 4' O.C. MAXIMUM SPACING.

NEW 2x2 CEILING TILES, ARMSTRONG - ULTIMA HEALTH

ZONE HIGH NRC, BEVELED TEGULAR (WHITE) HUMIDITY

AND SAG RESISTANT

PROPOSED 2x2 LED LIGHTING FIXTURE. SEE FIXTURE "L1"

ON SHEET E-3 FOR FIXTURE DETAILS

EXISTING LIGHTING TO BE REMOVED, PACKAGED FOR RECYCLING AND DISPOSED OF PROPERLY.

EXISTING HVAC SUPPLY AND RETURN DIFFUSER TO BE REMOVED. SEE SHEET M-1 FOR INFORMATION ON

MECHANICAL.

EXISTING CEILING GRID AND CEILING TILES TO BE REMOVED AND DISPOSED OF. (BOLD DASHED LINES)

EXISTING CEILING MOUNTED PROJECTOR AND SCREEN TO BE REMOVED. PROJECTOR SHALL BE RETURNED

TO GOVERNMENT FOR STORAGE. SCREEN SHALL BE DISPOSED OF PROPERLY.

NEW 2 x 2 CEILING GRID TO BE INSTALLED WITH NEW MOISTURE RESISTANT 2 x 2 CEILING TILES.

NEW LIGHTS TO BE INSTALLED (TYPICAL OF 9). SEE SHEET E-1 FOR DETAILS.

NEW HVAC SUPPLY AND RETURN DIFFUSER TO BE INSTALLED. SEE SHEET M-1 FOR DETAILS.

WORKING NOTES

FA

C

IL

IT

IE

S

B R

A N

C H

EXISTING REFLECTED CEILING PLAN

SCALE: 14" = 1'-0"

INDICATES EXISTING LIGHTS TO BE REMOVED. EXISTING

LAMPS AND BALLASTS TO BE BOXED AND RETURNED TO

THE GOVERNMENT FOR RECYCLING. SEE SHEET E-1 FOR

LIGHTING PLANS.

1. CONTRACTOR SHALL VERIFY ALL DIMENSIONS IN THE FIELD PRIOR TO ORDERING MATERIAL.

2. CEILING HEIGHT TO BE 9'-0".

3. EXISTING EMERGENCY LIGHTS TO BE REPLACED USING NEW LEAD CALCIUM FIXTURE UTILIZING EXISTING LOCATION. SEE SHEET E-1 FOR LIGHTING PLAN AND SHEET E-3 FOR FIXTURE DETAILS.

EXISTING 2x4 CEILING GRID TO BE REMOVED AND

DISPOSED OF PROPERLY.

B R

E A

K R

O O

M R

E N

O V

A

TI

O N

S

SP

EXISTING PENDANT SPRINKLER HEAD TO BE REMOVED.

SP

NEW PENDANT SPRINKLER HEAD LOCATION.

EXISTING HVAC SUPPLY DIFFUSER TO BE REMOVED.

NEW HVAC SUPPLY DIFFUSER.

L1 L1 L1

L1L1L1

L1 L1 L1

5/

/2

5/

/2

5/

/2

EXISTING HVAC RETURN REGISTER TO BE REMOVED.

NEW HVAC RETURN REGISTER.

W2020-321-01

(TYPICAL)

(TYPICAL)

(TYPICAL)

(TYPICAL)

TT

D E

P A

R

TM

E N

T O

F

TH

E N

A V

Y

N E

W P

O R

T, R

H O

D E

IS

LA

N D

N A

V A

L U

N D

E R

S E

A W

A R

FA

R

E C

E N

TE

R

D

IV

IS

IO

N

SHEET OF

CONTRACT NO.

NAVFAC DRAWING NO.

NUWC DRAWING NO.

SCALE:

SIZE: ANSI D

A P

P R

O V

E D

C H

E C

K E

D B

Y

D E

S

IG

N E

D B

Y

D R

A W

N B

Y

D A

TE

S A

TI

S

FA

C

TO

R

Y T

O D

A

TE

D A

TE

D A

TE

D A

TE

R E

V

IS

IO

N

S S

Y M

D E

S C

R

IP

TI

O

N D

A

TE

A P

P R

AS NOTED

21-016A

S .T

IL

LE

Y

S .T

6 11

M-1

B U

IL

D

IN

G

E

X

IS

TI

N

G / N

E W

H V

A C

P

LA

N

NEW HVAC PLAN

SCALE: 14" = 1'-0"

LEGEND:

1 SPECIFIC WORK NOTE

FA

C

IL

IT

IE

S

B R

A N

C H

EXISTING HVAC PLAN

SCALE: 14" = 1'-0"

B R

E A

K R

O O

M R

E N

O V

A

TI

O N

S

INDICATES EXISTING HVAC SUPPLY REGISTER TO BE MOVED

INDICATES NEW HVAC SUPPLY REGISTER

34x16 38x16 x6 x1

24x22 x6 x1

9x12 CFM

2- 9x12 CFM'S

335 EA.

9x12 CFM

12x12 CD

12x12 CD

12x12 CD

12x12 CD x6 x1 x6 x1

9x12 CFM

2- 9x12 CFM'S

335 EA.

9x12 CFM

12x12 CD

12x12 CD

12x12 CD

12x12 CD

12x12 CD

HVAC DEMOLITION NOTES:

NEW FRESH AIR SUPPLY AND RETURN TO BE PROVIDED FOR REENOVATION.

INDICATES FRESH AIR RETURN TO BE RELOCATED AS INDICATED AFTER NEW

CEILING GRID AND TILES HAVE BEEN INSTALLED. SEE SHEET A-1 FOR NEW

LOCATION WITHIN NEW CEILING GRID.

1.

NEW HVAC NOTES:

NEW AIR SUPPLY DUCT TO BE CONNECTED TO EXISTING 24x22 DUCT WITH 6"

ROUND DUCT (SEE BRANCH CONNECTION DETAIL ON THIS SHEET). NEW AIR

RETURN TO BE CONNECTED TO EXISTING 38x16 MAIN RETURN DUCT WITH 6x6

DUCT WORK.

INDICATES LOCATION OF NEW AIR RETURN. NEW RETURN REGISTER TO MATCH

EXISTING SURFACE MOUNTED WITH SATIN FINISH.

NEW AIR SUPPLY AIR DUCT 6" ROUND. NEW SUPPLY TO MATCH EXISTING SURFACE

MOUNTED WITH SATIN FINISH.

INDICATES NEW LOCATION OF EXISTING AIR RETURN. PROVIDE MODIFICATIONS TO

EXISTING DUCT WORK AS REQUIRED.

5.

7.

DUCT MAIN

SPIN TAP SHALL

BE FULL SIZE OF

DIFFUSER NECK

WITH VD.

INSULATE

DIFFUSER NECK

OPPOSED BLADE

DAMPER

T-BAR

CEILING DIFFUSER (TYP.)

SUSPENDED CEILING

BAND AT

DIFFUSER NECK

DIFFUSER NECK

ATTACH METALLIC FLEX

DUCT TO DIFFUSER

NECK WITH BAND (MAX

LENGTH OF 5'-0")

BAND

DIFFUSER CONNECTION DETAIL

NTS

BRANCH CONNECTION DETAIL

NTS

MAIN DUCT

45°

BRANCH DUCT

VOLUME DAMPER

NOTE: THIS CONNECTION SHALL BE

USED AT ALL BRANCHES FROM

MAINS AND SUB-MAINS. BALANCING

DAMPERS SHALL BE PROVIDED.

8" ROUND DUCT

INDICATES EXISTING HVAC RETURN DIFFUSER TO BE MOVED

INDICATES NEW HVAC RETURN DIFFUSER

T INDICATES EXISTING THERMOSTAT LOCATION

5/

/2

5/

/2

5/

/2

2 2

2 2

6 6

8 8 8

W2020-321-01

1 SPECIFIC DEMOLITION NOTE

RETURN DUCT

SUPPLY DUCT

R .N

E

LS

O N

9x12 CFM

RETURN DUCT

34x16 38x16

24x22

RETURN DUCT

SUPPLY DUCT

RETURN DUCT

J J J

J J J

J J J

J J J

S

WORK REQ. NO.

D E

P A

R

TM

E N

T O

F

TH

E N

A V

Y

N E

W P

O R

T, R

H O

D E

IS

LA

N D

N A

V A

L U

N D

E R

S E

A W

A R

FA

R

E C

E N

TE

R

D

IV

IS

IO

N

SHEET OF

CONTRACT NO.

NAVFAC DRAWING NO.

NUWC DRAWING NO.

SCALE:

SIZE: ANSI D

A P

P R

O V

E D

C H

E C

K E

D B

Y

D E

S

IG

N E

D B

Y

D R

A W

N B

Y

D A

TE

S A

TI

S

FA

C

TO

R

Y T

O D

A

TE

D A

TE

D A

TE

D A

TE

R E

V

IS

IO

N

S S

Y M

D E

S C

R

IP

TI

O

N D

A

TE

A P

P R

AS NOTED

21-016A

S .T

IL

LE

Y

S .T

7 11

E-1

B U

IL

D

IN

G

E

X

IS

TI

N

G / N

E W

L

IG

H

TI

N G

P

LA

NFA

C

IL

IT

IE

S

B R

A N

C H

B R

E A

K R

O O

M R

E N

O V

A

TI

O N

S

LEGEND:

GENERAL NOTES

L1

1 WORK NOTE

NEW 2'x 2' LED LIGHTING FIXTURE. SEE FIXTURE "L1" ON

SHEET E-1 FOR DETAILS

WORKING NOTES

INDICATES EXISTING LIGHTS TO BE REMOVED. EXISTING

BALLASTS AND LAMPS TO BE BOXED FOR RECYCLING

PURPOSES. SEE THIS SHEET FOR LIGHTING REMOVAL.

INDICATES EXISTING EMERGENCY LIGHTS TO BE REMOVED. SEE

THIS SHEET FOR DETAILS. BATTERY TO BE BOXED FOR

RECYCLING PURPOSES.

1/4"=1'-0"

5' 0' 5' 10' 15' 20'

GRAPHIC SCALE

SPECIFIC DEMOLITION NOTES1

INDICATES EXISTING CEILING MOUNTED LIGHTS TO BE REMOVED

AND DISPOSED OF PROPERLY.

INDICATES EXISTING EMERGENCY LIGHTS TO BE REMOVED AND

DISPOSED OF PROPERLY. NEW EMERGENCY LIGHTS TO INSTALLED

IN SAME LOCATION (1).

3 INDICATES NEW 2x2 LIGHT FIXTURES TO BE INSTALLED . SEE

LIGHTING PLATE "L1" ON SHEET E-3.

4 INDICATES NEW EMERGENCY LIGHTS TO BE INSTALLED IN SAME

LOCATION AS THE ONES THAT WERE REMOVED. SEE LIGHTING PLATE

"L3" ON SHEET E-3.

5.

1. CONTRACTOR SHALL VERIFY ALL DIMENSIONS IN FIELD PRIOR TO ORDERING MATERIALS.

2. UNLESS INDICATED OTHERWISE, ALL ITEMS IN BOLD ARE NEW.

3. ALL ELECTRICAL WIRING SHALL BE IN ACCORDANCE WITH ALL APPLICABLE LOCAL, STATE AND FEDERAL REGULATIONS AND SHALL COMPLY WITH THE NEWEST EDITION OF THE NATIONAL ELECTRICAL

CODE (NEC) AND THE NATIONAL ELECTRICAL SAFETY CODE (NESC).

4. ALL NEW CONDUIT AND WIRING SHALL BE CONCEALED TO THE GREATEST EXTENT POSSIBLE ABOVE SUSPENDED CEILING AND WITHIN NEW WALLS. ALL NEW CIRCUITS SHALL UTILIZE 3/12'S IN 3 4" EMT UNLESS INDICATED OTHERWISE. AT THE CONTRACTORS OPTION, ALL PORTIONS OF 20 AMP BRANCH CIRCUITS CONCEALED WITHIN WALLS OR ABOVE SUSPENDED CEILING MAY UTILIZE METAL CLAD CABLE CONTAINING 3# 12'S (COLOR CODED). ALL WIRING SHALL BE COPPER. ALL WIRING OF SIZES NO.10 AND

SMALLER SHALL BE SOLID VICE STRANDED CONSTRUCTION.

5. CONTRACTORS SHALL PROVIDE A GREEN INSULATED EQUIPMENT GROUND CONDUCTOR IN ALL

CIRCUITS AND TO ALL NON-CURRENT CARRYING METALLIC ITEMS.

6. ALL NEW PENETRATIONS SHALL BE SEALED. ALL HOLES LEFT BY REMOVALS SHALL BE PREPARED AND PAINTED TO MATCH EXISTING ADJACENT SURFACES. ALL HOLES LEFT IN ELECTRICAL BOXES, PANELS, COVERS,...ETC. SHALL BE PROVIDED WITH KNOCKOUT CLOSURE PIECES.

7. ALL SWITCHES, SENSORS, DEVICES AND DEVICE PLATES,...ETC. SHALL BE WHITE IN COLOR.

EXISTING LIGHTING PLAN

SCALE: 14" = 1'-0"

NEW LIGHTING PLAN

SCALE: 14" = 1'-0"

LP1-7

LP2-2 LP2-2 LP2-2

LP2-2LP2-2LP2-2

LP2-2 LP2-2 LP2-2

EXISTING WIRING FOR LIGHTS

CONNECTED TO JUNCTION

BOX IN ADJACENT ROOM

LP1-7

L5

L5

INDICATES EXISTING EXIT SIGNS TO BE REMOVED. NEW

EXIT SIGNS WILL REPLACE ORIGINAL IN EXISTING

LOCATION. SEE SHEET E-3 FOR FIXTURE DETAILS. (L5)

5/

/2

5/

/2

5/

/2

J INDICATES EXISTING JUNCTION BOX ABOVE CEILING.

W2020-321-01

R .N

E

LS

O N

(TYPICAL)

S INDICATES NEW LIGHT SWITCH TO BE INSTALLED.

(TYPICAL)

"L1"

"L3"

INDICATES NEW EMERGENCY LIGHTS TO BE INSTALLED.

NEW EMERGENCY LIGHTS WILL REPLACE ORIGINAL IN

EXISTING LOCATION. SEE THIS SHEET FOR DETAILS. (L3)

L3

L5

SEE REFLECTED CEILING PLAN ON SHEET A-3 FOR EXACT

LOCATIONS WITHIN CEILING GRID. EXISTING CEILING HEIGHT IS

9'-1". NEW CEILING HEIGHT TO BE THE SAME.

E

P A

R

TM

E N

T O

F

TH

E N

A V

Y

N E

W P

O R

T, R

H O

D E

IS

LA

N D

N A

V A

L U

N D

E R

S E

A W

A R

FA

R

E C

E N

TE

R

D

IV

IS

IO

N

SHEET OF

CONTRACT NO.

NAVFAC DRAWING NO.

NUWC DRAWING NO.

SCALE:

SIZE: ANSI D

A P

P R

O V

E D

C H

E C

K E

D B

Y

D E

S

IG

N E

D B

Y

D R

A W

N B

Y

D A

TE

S A

TI

S

FA

C

TO

R

Y T

O D

A

TE

D A

TE

D A

TE

D A

TE

R E

V

IS

IO

N

S S

Y M

D E

S C

R

IP

TI

O

N D

A

TE

A P

P R

AS NOTED

21-016A

S .T

IL

LE

Y

S .T

8 11

E-2

B U

IL

D

IN

G

E

X

IS

TI

N

G / N

E W

E

LE

C

TR

IC

A

L P

LA

N

FA

C

IL

IT

IE

S

B R

A N

C H

B R

E A

K R

O O

M R

E N

O V

A

TI

O N

S

LEGEND: GENERAL NOTES

1 WORK NOTE

WORKING NOTES

INDICATES EXISTING ELECTRICAL OUTLET TO REMAIN.

CIRCUIT SHALL BE VERIFIED BEFORE WORK BEGINS.

INDICATES PANEL AND CIRCUIT NUMBER

INDICATES EXISTING EMERGENCY LIGHTS TO BE

REMOVED. NEW EMERGENCY LIGHTS WILL REPLACE

ORIGINAL IN EXISTING LOCATION. SEE THIS SHEET FOR

DETAILS. (L3)

L3

1/4"=1'-0"

5' 0' 5' 10' 15' 20'

GRAPHIC SCALE

SPECIFIC DEMOLITION NOTES1

1. CONTRACTOR SHALL VERIFY ALL DIMENSIONS IN FIELD PRIOR TO ORDERING MATERIALS.

2. UNLESS INDICATED OTHERWISE, ALL ITEMS IN BOLD ARE NEW.

3. ALL ELECTRICAL WIRING SHALL BE IN ACCORDANCE WITH ALL APPLICABLE LOCAL, STATE AND

FEDERAL REGULATIONS AND SHALL COMPLY WITH THE NEWEST EDITION OF THE NATIONAL

ELECTRICAL CODE (NEC) AND THE NATIONAL ELECTRICAL SAFETY CODE (NESC).

4. ALL NEW CONDUIT AND WIRING SHALL BE CONCEALED TO THE GREATEST EXTENT POSSIBLE

ABOVE SUSPENDED CEILING AND WITHIN NEW WALLS. ALL NEW CIRCUITS SHALL UTILIZE 3/12'S IN 3 4" EMT UNLESS INDICATED OTHERWISE. AT THE CONTRACTORS OPTION, ALL PORTIONS OF

20 AMP BRANCH CIRCUITS CONCEALED WITHIN WALLS OR ABOVE SUSPENDED CEILING MAY

UTILIZE METAL CLAD CABLE CONTAINING 3# 12'S (COLOR CODED). ALL WIRING SHALL BE

COPPER. ALL WIRING OF SIZES NO.10 AND SMALLER SHALL BE SOLID VICE STRANDED

CONSTRUCTION.

5. CONTRACTORS SHALL PROVIDE A GREEN INSULATED EQUIPMENT GROUND CONDUCTOR IN ALL

CIRCUITS AND TO ALL NON-CURRENT CARRYING METALLIC ITEMS.

6. ALL NEW PENETRATIONS SHALL BE SEALED. ALL HOLES LEFT BY REMOVALS SHALL BE

PREPARED AND PAINTED TO MATCH EXISTING ADJACENT SURFACES. ALL HOLES LEFT IN

ELECTRICAL BOXES, PANELS, COVERS,...ETC. SHALL BE PROVIDED WITH KNOCKOUT CLOSURE

PIECES.

7. ALL SWITCHES, SENSORS, DEVICES AND DEVICE PLATES,...ETC. SHALL BE WHITE IN COLOR.

EXISTING ELECTRICAL POWER PLAN

SCALE: 14" = 1'-0"

NEW ELECTRICAL POWER PLAN

SCALE: 14" = 1'-0"

PP6 (27)

PP6 (3)

PP6 (14)

PP6 (3)

PP6 (1)

INDICATES EXISTING EXIT SIGNS TO BE REMOVED. NEW

EXIT SIGNS WILL REPLACE ORIGINAL IN EXISTING

LOCATION. SEE THIS SHEET FOR DETAILS. (L5)

5/

/2

5/

/2

5/

/2

INDICATES NEW LOCATION OF PHONE CABINET. PHONE CABINET

INCLUDES PIPING GOING UP THROUGH EXISTING CEILING GRID.

CABINET TO BE ROTATED AS SHOWN ON NEW ELECTRICAL POWER

PLAN.

W2020-321-01

INDICATES NEW 20 AMP GFCI RECEPTACLE MOUNTED AT

COUTERTOP HEIGHT.

INDICATES PANEL AND CIRCUIT NUMBERPP6 (1)

EXISTING PROJECTOR AND SCREEN TO BE REMOVED AND RETURNED

TO GOVERNMENT. ASSOCIATED ELECTRICAL TO REMAIN INTACTED

DURING CONSTRUCTION.

EXISTING PHONE CABINET TO BE ROTATED. WORK TO BE DONE WITH

MINIMAL DISTURBANCE TO CABINET.

INDICATES EXSISTING QUAD BOX RECEPTACLE TO BE

REMOVED. NEW CIRCUIT TO PANEL NEEDS TO BE

INDICATED ON PANEL SCHEDULE.

INDICATES PANEL AND CIRCUIT NUMBER

PP6 (1)

R .N

E

LS

O N

INDICATES NEW RECEPTACLES TO BE INSTALLED. COUNTERTOP

RECEPTACLES TO BE 36" A.F.F.

C

GFCI

C

GFCI

COUNTER HEIGHT (36"A.F.F.)

PP6 (5) PP6 (9)

PP6 (14)

PP6 (3)

PP6 (12)

PP6 (3)

PP6 (15)

PP6

(17,18)

PP6 (5)

PP6 (27)

PP6 (3)PP6 (5) PP6 (9)

PP6 (3)

PP6 (5)

PP6 (3)

C

GFCI

PP6 (3)

C

GFCI

PP6 (12)

PP6 (14)

5 INDICATES NEW RECEPTACLES TO BE INSTALLED. RECEPTACLES

TO BE 18" A.F.F.

INDICATES EXISTING CEILING MOUNTED RECEPTACLE TO

BE REMOVED.

PP6 (15)

S

EXISTING

LIGHT SWITCH

TO REMAIN

S

E

P A

R

TM

E N

T O

F

TH

E N

A V

Y

N E

W P

O R

T, R

H O

D E

IS

LA

N D

N A

V A

L U

N D

E R

S E

A W

A R

FA

R

E C

E N

TE

R

D

IV

IS

IO

N

SHEET OF

CONTRACT NO.

NAVFAC DRAWING NO.

NUWC DRAWING NO.

SCALE:

SIZE: ANSI D

A P

P R

O V

E D

C H

E C

K E

D B

Y

D E

S

IG

N E

D B

Y

D R

A W

N B

Y

D A

TE

S A

TI

S

FA

C

TO

R

Y T

O D

A

TE

D A

TE

D A

TE

D A

TE

R E

V

IS

IO

N

S S

Y M

D E

S C

R

IP

TI

O

N D

A

TE

A P

P R

AS NOTED

21-016A

S .T

IL

LE

Y

S .T

9 11

E-3

B U

IL

D

IN

G

LI

G H

TI

N

G D

E

TA

IL

S

FA

C

IL

IT

IE

S

B R

A N

C H

B R

E A

K R

O O

M R

E N

O V

A

TI

O N

S

5/

/2

5/

/2

5/

/2

DIRECT/INDIRECT LED TROFFER

NL-1LIGHTING PLATE:

EMERGENCY LIGHT FIXTURE

LIGHTING PLATE:

L1

L3

LUMINAIRE REQUIREMENTS:

1. UNIT SHALL BE CONSTRUCTED OF 20 GAUGE STEEL WITH AN

OFF WHITE BAKED ENAMEL FINISH WITH REMOVABLE FRONT

COVER. CONFORM TO UL 924 AND NFPA 101.

2. THE UNIT SHALL BE DUAL RATED FOR USE ON EITHER 120 OR

277 VOLT ALTERNATING CURRENT POWER SUPPLIES.

FOLLOWING A SUSTAINED LOSS OF THE NORMAL POWER

SUPPLY. THE UNIT SHALL BE CAPABLE OF AUTOMATICALLY

AND INSTANTANEOUSLY ILLUMINATING THE 6-VOLT LIGHTING

FIXTURES FOR A PERIOD OF NOT LESS THAN 90 MINUTES AT A

BATTERY VOLTAGE IN EXCESS OF 87.5 PERCENT OF THE

NOMINAL VOLTAGE RATING.

3. THE BATTERY SHALL BE LEAD CALCIUM AND DESIGNED TO BE

MAINTENANCE FREE DURING THE EXPECTED BATTERY LIFE,

AND SHALL BE WARRANTED FOR NOT LESS THAN 3 YEARS

FROM THE DATE OF THE PURCHASE OF THAT UNIT, AND

SHALL BE FIELD REPLACEABLE WITHOUT REQUIRING

REMOVAL OF OTHER COMPONENTS. PROVIDE PULSE PLUS

CHARGER CIRCUITRY, FUSED OUTPUTS, DIAGNOSTIC

INDICATOR LIGHTS, LOW VOLTAGE BATTERY DISCONNECT,

BROWNOUT PROTECTION AND BATTERY LOCKOUT WITH

AUTOMATIC BATTERY CONNECT. THE BATTERY AND CHARGER

SHALL BE CONTAINED IN A WHITE/OFF WHITE METALLIC

CABINET, UNLESS APPROVED OTHERWISE, AND SHALL BE

EQUIPPED WITH A PUSH-TO-TEST SWITCH AND A METER TO

INDICATE BATTERY VOLTAGE.

4. THE UNIT SHALL BE PRE-WIRED AND EQUIPPED WITH TWO 4

WATT L.E.D. HEADS.

5. UNIT SHALL INCLUDE SELF DIAGNOSTIC CAPABILITY TO

PERFORM A 30 SECOND TEST EVERY 30 DAYS AND A 90 MIN

TEST ANNUALLY. IF UNIT FAILS ANY TEST, AN INTERNAL

AUDIBLE ALARM WILL SOUND UNTIL ACKNOWLEDGED.

6. UNIT SHALL BE EQUIVALENT TO EMERGI-LITE LSM54-210LA-AD

SERIES.

LUMINAIRE REQUIREMENTS:

1. HOUSING - DIE-FORMED, COLD ROLLED STEEL, WITH ON-PIECE

LOWER REFLECTOR HAVING TEXTURED, HIGH REFLECTANCE,

WHITE POLYESTER POWDER-COATED FINISH. SIZE OF 2'x2'.

2. LIGHT SOURCE - UPWARD- FACING LEDS WITH DIFFUSE LENS TO

ELIMINATE DIRECT VIEW OF LIGHT SOURCE. 4000K COLOR

TEMPERATURE UON, MAXIMUM BINNING TOLERANCE OF A

4-STEP MCADAM ELLIPSE, MINIMUM EFFICACY OF 90

LUMENS/WATT, WITH A MINIMUM CRI OF 80. INITIAL LUMEN

OUTPUT OF 2900 LUMENS.

3. DRIVER - REPLACEABLE, INTEGRAL, HIGH-EFFICIENCY DRIVER

WITH MINIMUM 0.9 PF, OPERATING VOLTAGE OF 120-277V,

THERMAL MANAGEMENT, <20% TOTAL HARMONIC DISTORTION.

PROVIDE WITH A 0-10 VOLT FULLY DIMMABLE DRIVER.

4. CERTIFICATION - UL1598, DAMP LOCATION, DLC QUALIFIED,

AND ROHS COMPLIANT. COMPLIES WITH LM79, LM80 AND TM21

TESTING STANDARDS. IC RATED WHEN INDICATED.

5. MOUNTING - RECESSED IN SUSPENDED ACOUSTICAL TILE OR

HARD CEILING.

6. FIXTURE SHALL BE EQUIVALENT TO METALUX CRUZE MODEL

22CZ-LD5-29-UNV-L840-CD1-SVPD1-V. THIS IS NOT INTENDED TO

BE PROPRIETARY, OTHER MANUFACTURERS WITH EQUIVALENT

PRODUCTS ARE ACCEPTABLE.

ALL FIXTURES TO HAVE

ALL FOUR CORNERS

SECURED TO THE

STRUCTURE ABOVE

INDEPENDENT OF THE

CEILING SUSPENSION

SYSTEM (TYP)

13"

NOMINAL

NOMINAL

9"

LED EXIT SIGN

NL-63LIGHTING PLATE:

L5

LUMINAIRE REQUIREMENTS:

1. HOUSING - DIE-CAST ALUMINUM OR STEEL CONSTRUCTION,

SINGLE OR DOUBLE-FACED AS INDICATED.

2. FINISH - POWDER COAT FINISH OPTIONS INCLUDE WHITE OR

BRUSHED ALUMINUM FACE, BLACK, OR BLACK WITH BRUSHED

ALUMINUM FACE. LETTERS/CHEVRONS- MINIMUM 6" HIGH WITH

4" STROKE. RED LETTERS.

3. AS INDICATED, PROVIDE CHEVRONS AS INDICATED EITHER

LEFT, RIGHT OR BOTH DIRECTIONS AS INDICATED, CHEVRONS

PUNCHED OUT THROUGH HOUSING AS REQUIRED.

4. EMERGENCY PACK - SOLID-STATE, CONSTANT-CURRENT TYPE

BATTERY CHARGER WITH MAINTENANCE-FREE,

NICKEL-CADMIUM BATTERY, AC-ON INDICATOR LAMP AND TEST

SWITCH.

5. MOUNTING - UNIVERSAL MOUNTING KIT FOR CEILING, WALL OR

END-OF-FIXTURE MOUNTING.

6. ILLUMINATION - PROVIDED BY RED HIGH-OUTPUT LEDS INSIDE

OF FIXTURE HOUSING. PROVIDE POLYSTYRENE DIFFUSER IN

COLOR INDICATED WITH FREQUENCY-MATCHED SILKSCREEN

COATING FOR MAXIMUM LED LIGHT OUTPUT.

7. CERTIFICATION - UL LISTED AND CERTIFIED FOR DAMP

LOCATIONS, UNIT SHALL CONFORM TO UL 924, UL 1571, AND

NFPA 101.

8. PROVIDE UNIT WITH SELF DIAGNOSTICS OPTION THAT

PERFORMS SELF TESTING OF UNIT FOR 30 SECONDS EVERY 30

DAYS AND FOR 90 MINUTES ANNUALLY SO AS TO MEET NFPA

101 LIFE SAFETY CODE FOR PERIODIC TESTING. UNIT SHALL

SOUND AN INTEGRAL AUDIBLE ALARM AND ILLUMINATE A LAMP

SHOULD ANY TESTS FAIL.

9. UNIT SHALL BE EQUIVALENT TO COOPER SURE LITES SLX7SD

SERIES.

W2020-321-01

R .N

E

LS

O N

E

P A

R

TM

E N

T O

F

TH

E N

A V

Y

N E

W P

O R

T, R

H O

D E

IS

LA

N D

N A

V A

L U

N D

E R

S E

A W

A R

FA

R

E C

E N

TE

R

D

IV

IS

IO

N

SHEET OF

CONTRACT NO.

NAVFAC DRAWING NO.

NUWC DRAWING NO.

SCALE:

SIZE: ANSI D

A P

P R

O V

E D

C H

E C

K E

D B

Y

D E

S

IG

N E

D B

Y

D R

A W

N B

Y

D A

TE

S A

TI

S

FA

C

TO

R

Y T

O D

A

TE

D A

TE

D A

TE

D A

TE

R E

V

IS

IO

N

S S

Y M

D E

S C

R

IP

TI

O

N D

A

TE

A P

P R

AS NOTED

21-016A

S .T

IL

LE

Y

S .T

10 11

P-1

NEW PLUMBING PLAN

SCALE: 14" = 1'-0"

B U

IL

D

IN

G

E

X

IS

TI

N

G / N

E W

P

LU

M B

IN

G

EXISTING PLUMBING PLAN

SCALE: 14" = 1'-0"

PLUMBING NOTES:

ALL EXISTING PLUMBING FIXTURES TO BE REMOVED AND DISPOSED OF,

INCLUDING WATER FOUNTAIN. ASSOCIATED PLUMBING TO BE REUSED.

EXISTING HOT WATER TANK TO BE REMOVED AND REUSED UNERSINK IN NEW

CABINETS TO BE INSTALLED. PLUMBING TO BE MODIFIED TO NEW LOCATION

AND EXISTING ELECTRICAL SUPPLY TO BE USED.

PROVIDE A 20"x 25"x 8" DEPTH (MINIMUM) UNDER-MOUNT STAINLESS STEEL

BAR SINK WITH HOT AND COLD WATER AND GOOSE NECK STYLE FAUCET.

EXISTING PLUMBING TO BE USED IN NEW SINK INSTALLATION. EXISTING

DRAIN TO BE PLUMBED INTO NEW SINK LOCATION.

NEW SHUT OFF VALVE TO BE INSTALLED ABOVE CEILING. NEW COLD WATER

SUPPLY TO BE INSTALLED IN NEW WALL TO BE INSTALLED. EXISTING COLD

WATER SUPPLY IN CMU BLOCK WALL TO BE REMOVED.

1. GENERAL NOTES ON THIS DRAWING ARE APPLICABLE TO EACH PLUMBING DRAWING OF THIS SET. SEE EACH

DRAWING FOR SPECIFIC NOTES APPLICABLE TO THAT DRAWING.

2. OVERHEAD PIPING IN SPACES WITH CEILINGS SHALL BE CONCEALED OR IN WALLS OR CHASES UNLESS

OTHERWISE NOTED.

3. COORDINATE LOCATION AND INSTALLATION OF EQUIPMENT WITH OTHER TRADES.OFFSET PIPING AROUND

OBSTRUCTIONS AT NO ADDITIONAL COST TO THE GOVERNMENT.

4. PROVIDE UNION OR FLANGE CONNECTIONS AT EACH PIECE OF EQUIPMENT. PROVIDE SHUT-OFF VALVES AT

EACH PIECE OF EQUIPMENT AND TAKEOFFS.

5. PIPING SHALL BE SUPPORTED IN ACCORDANCE WITH THE SPECIFICATION. ADDITIONAL SUPPORTS OR HANGERS SHALL BE ADJACENT TO ELBOWS, TO PREVENT WEIGHT OF PIPING BEING PLACED ON EQUIPMENT.

6. EXISTING PIPING AND EQUIPMENT SHOWN IS BASED ON EXISTING AND FIELD OBSERVATION WITHOUT DEMOLITION. DURING DEMOLITION, ANY CLARIFICATION REQUIRED TO DETERMINE SCOPE OF WORK SHALL

BE BROUGHT TO THE ATTENTION OF THE CONTRACTING OFFICER.

7. DRAWINGS DO NOT SHOW EVERY EXISTING PIPE, CONDUIT, DUCT,... ETC. CONTRACTOR SHALL TAKE CARE TO REMOVE ONLY ITEMS REQUIRED TO BE REMOVED AND VERIFY PIPES, DUCTS,...ETC. BEFORE REMOVAL.

8. INSTALL ALL EQUIPMENT IN STRICT ACCORDANCE WITH MANUFACTURER'S WRITTEN INSTRUCTIONS.

9. PATCH ALL HOLES FROM REMOVAL OF PIPING, DUCTWORK, AND/OR EQUIPMENT TO MATCH EXISTING

ADJACENT CONSTRUCTION.

10. PROVIDE ALL MATERIALS AND EQUIPMENT AND PERFORM ALL LABOR REQUIRED TO INSTALL COMPLETE AND OPERABLE PLUMBING SYSTEMS AS INDICATED ON THE DRAWINGS, SPECIFIED AND REQUIRED BY

CODE.

11. FIELD VERIFY ALL DIMENSIONS.

12. COORDINATE WITH THE ARCHITECTURAL DRAWINGS PRIOR TO INSTALLING PLUMBING EQUIPMENT.

13. IT IS THE INTENTION OF THE DRAWINGS TO COVER ALL WORK AND MATERIAL FOR A COMPLETE FIRST CLASS INSTALLATION. ANY EQUIPMENT, TRIM HARDWARE AND/OR DEVICES USUALLY UTILIZED IN CLASS OF WORK, THOUGH NOT SPECIFICALLY MENTIONED OR SHOWN ON THE DRAWINGS, BUT WHICH MAY BE NECESSARY FOR THE SATISFACTORY COMPLETION OF WORK (AS DETERMINED BY THE CONTRACTING OFFICER) SHALL

BE FURNISHED AND INSTALLED BY THE CONTRACTOR AS PART OF HIS TOTAL WORK.

14. CONTRACTOR SHALL GUARANTEE ALL WORK FOR A PERIOD OF ONE YEAR FROM DATE OF SUBSTANTIAL

COMPLETION.

15. EXISTING PIPE AND EQUIPMENT SIZES NOTED ARE FOR THE CONVENIENCE OF THE CONTRACTOR ONLY AND ARE NOT WARRANTED TO BE CORRECT. THE CONTRACTOR SHALL FIELD VERIFY ALL EXISTING PIPE AND

EQUIPMENT SIZES AND THEIR RESPECTIVE LOCATIONS BEFORE PROCEEDING WITH ANY WORK.

16. AFTER THE PIPING IS INSULATED, PROVIDE SETON BRAND OR EQUAL FACTORY-FABRICATED PIPE LABELS, WITH DIRECTION OF FLOW ARROWS, ON THE PIPING, AT 10 FEET ON CENTER ON THE PIPING MAINS AND 5 FEET ON CENTER ON THE BRANCH RUNOUTS FROM MAINS. FOLLOW COLOR CODING OF ASME A13.1.

17. MAKE PROPER PIPING CONNECTIONS TO ALL FIXTURES AND EQUIPMENT EVEN THOUGH ALL BRANCH

MAINS, ELBOWS AND CONNECTIONS ARE NOT SHOWN.

18. ALL PIPING SHALL BE LOCATED AND DETERMINED WHERE TO BE RUN TO AVOID CONFLICT WITH OTHER

TRADES.

19. ALL PLUMBING VENTS WITHIN A 10'-0" RADIUS OF EXHAUST VENTS SHALL BE EXTENDED TO HEIGHT OF 2'-0"

ABOVE EXHAUST VENT CROWN.

20. ALL HOT AND COLD WATER PIPING INDICATED TO BE RUN ABOVE FINISHED CEILINGS OR IN EXTERIOR WALLS SHALL BE INSTALLED ON THE CONDITIONED SPACE SIDE OF THE BUILDING INSULATION.

GENERAL NOTES:

FA

C

IL

IT

IE

S

B R

A N

C H

B R

E A

K R

O O

M R

E N

O V

A

TI

O N

S

5/

/2

5/

/2

5/

/2

2" COLD WATER

PIPE LOCATED

ABOVE CEILING

W2020-321-01

R .N

E

LS

O N

PLUMBING LEGEND:

INDICATES EXISTING COLD WATER PIPING.

INDICATES NEW COLD WATER PIPING.

INDICATES EXISTING SHUT VALVES TO REMAIN.

INDICATES EXISTING SANITARY PIPES TO REMAIN.

INDICATES CONNECTION POINT BETWEEN NEW AND

EXISTING SUPPLY LINES.

EXISTING VENT

PIPE TO REMAIN

2" COLD WATER

PIPE LOCATED

ABOVE CEILING

EXISTING VENT

PIPE TO REMAIN

VENT PIPE IN

CMU WALL

COLD WATER

SUPPLY IN

CMU WALL

SANITARY

WASTE PIPE IN

CMU WALL

EXISTING HOT

WATER TANK

UNDER SINK

IN CABINET

SINK DRAIN

HOT WATER

TO EXISTING

SINK

WATER SUPPLY TO EXISTING SINK

E

P A

R

TM

E N

T O

F

TH

E N

A V

Y

N E

W P

O R

T, R

H O

D E

IS

LA

N D

N A

V A

L U

N D

E R

S E

A W

A R

FA

R

E C

E N

TE

R

D

IV

IS

IO

N

SHEET OF

CONTRACT NO.

NAVFAC DRAWING NO.

NUWC DRAWING NO.

SCALE:

SIZE: ANSI D

A P

P R

O V

E D

C H

E C

K E

D B

Y

D E

S

IG

N E

D B

Y

D R

A W

N B

Y

D A

TE

S A

TI

S

FA

C

TO

R

Y T

O D

A

TE

D A

TE

D A

TE

D A

TE

R E

V

IS

IO

N

S S

Y M

D E

S C

R

IP

TI

O

N D

A

TE

A P

P R

AS NOTED

21-016A

S .T

IL

LE

Y

S .T

11 11

FP-1

NEW FIRE PROTECTION PLAN

SCALE: 14" = 1'-0"

B U

IL

D

IN

G

E

X

IS

TI

N

G / N

E W

F

IR

E P

R O

TE

C

TI

O

N P

LA

N

EXISTING FIRE PROTECTION PLAN

SCALE: 14" = 1'-0"

TYPICAL PENDANT SPRINKLER

SCALE: NTS

NOTES: ADJUST SPRINKLER DROPS AS NECESSARY TO CLEAR OBSTRUCTIONS SUCH AS

THE CEILING "T" BAR SUSPENSION SYSTEM, LIGHTING FIXTURES,ETC. PROVIDE A PIPE

HANGER IF THE HORIZONTAL OFFSET LENGTH EXCEEDS 24".

1" BLACK STEEL SCHEDULE

40 PIPING, TYP.

PROVIDE NEW CHROME PENDANT

SPRINKLER HEAD (155 DEGREE F)

1" x 1/2" PIPE REDUCING COUPLING

FIRE PROTECTION NOTES

1. EXISTING SPRINKLER HEADS TO BE REMOVED (DARK DASHED).

2. NEW PENDANT SPRINKLER HEADS TO BE INSTALLED (BOLD).

SEE DETAIL ON THIS SHEET. NEW PIPING TO BE INSTALLED

FROM EXISTING PENDANT LOCATION.

LEGEND:

INDICATES NEW SPRINKLER HEADS (BOLD)

INDICATES EXISTING SPRINKLER PIPING (GRAY)

INDICATES NEW SPRINKLER PIPING (BOLD)

INDICATES EXISTING SPRINKLER HEADS TO BE MOVED (DASHED BOLD)

PROVIDE LENGTH TO SUIT

PROVIDE

LENGTH TO SUIT

1 INDICATES WORK NOTE

FA

C

IL

IT

IE

S

B R

A N

C H

EXISTING 2" BRANCH PIPE

B R

E A

K R

O O

M R

E N

O V

A

TI

O N

S

5/

/2

5/

/2

5/

/2

W2020-321-01

R .N

E

LS

O N

(TYPICAL)

(TYPICAL)

171 INDICATES ROOM NUMBER

INDICATES EXISTING SPRINKLER PIPING TO BE REMOVED (BOLD)

Sheets and Views
BLDG 1170 Breakroom Renovations-T-1
BLDG 1170 Breakroom Renovations-D-1
BLDG 1170 Breakroom Renovations-A-1
BLDG 1170 Breakroom Renovations-A-2
BLDG 1170 Breakroom Renovations-A-3
BLDG 1170 Breakroom Renovations-M-1
BLDG 1170 Breakroom Renovations-E-1
BLDG 1170 Breakroom Renovations-E-2
BLDG 1170 Breakroom Renovations-E-3
BLDG 1170 Breakroom Renovations-P-1
BLDG 1170 Breakroom Renovations-FP-1

File details come from the government source that posted it. Updated .