This document is a Statement of Work (SOW) and facility cleaning schedule for the Salt Lake City Air Traffic Control Tower (ATCT)/Terminal Radar Approach Control (TRACON) facility located at 1201 N. 4000 W., Salt Lake City, UT 84116. The facility operates 24 hours per day, 7 days per week with cleaning operations scheduled between 12:01 a.m. and 6:00 a.m. The total facility encompasses approximately 15,760 square feet, consisting of 10,567 square feet of carpeted space and 5,193 square feet of uncarpeted space.

The SOW specifies detailed cleaning requirements for 18 distinct area types, including operational areas, office spaces, conference rooms, reception areas, corridors, breakrooms, locker rooms, mechanical and equipment rooms, restrooms, guard house, elevators, and stairwells. Cleaning frequencies vary by area type and task, ranging from daily service (D7), twice daily (2D7), weekly (W), monthly (M), to quarterly (Q) intervals. The facility includes 8 total restrooms comprising 2 single-use, 3 medium multi-use, and 3 large multi-use configurations with a combined 789 square feet. Restroom fixtures total 23 toilets and 7 urinals. Additional service requirements address waste receptacles, grounds policing, surface and high-surface dusting, carpet shampooing, floor stripping and waxing, supply replenishment, disinfection, glass and fixture cleaning, and specialized maintenance for appliances, refrigerators, drinking fountains, HVAC registers, and dumpster areas. The document indicates all square footage and item counts are estimates provided for planning purposes only.

View the file

Other files

Show all 17

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Name & Ident of Facility: Salt Lake City ATCT/TRACON *All counts and Sq. Ft. provided are estimates for planning purposes only* Address: 1201 N. 4000 W., Salt Lake City, UT 84116 Facility Operating Hours: 24x7 Timeframe to clean Operational Area(s): 12:01am - 6:00am

General Frequency 24/7 Facilities

Occupancy 50+

Es t.

Ca rp et ed

Sq . F t.* Es t.

Un ca rp et ed

Sq . F t.* Es t.

To ta l S qu ar e Fo ot ag e*

(C um ul at iv e)

Ite m

C ou nt

W as te /R ec yc le R ec ep ta cle s Po lic in g G ro un ds

Sm ok in g R ec ep ta cle s Su rfa ce

D us tin g &

C lea ni ng

Hi gh

Su rfa ce D us tin g & C lea ni ng

Va cu um /P ol ish

Fu rn itu re

W in do ws

W in do w C ov er s Va cu um

C ar pe te d Flo or s, Ru gs

M at s Sh am po o Ca rp et ed Fl oo rs

, R ug s, & M at s Cl ea n/

M op

U nc ar pe te d

Flo or s

Cl ea n/ St rip /W ax /B uf f

Un ca rp et ed Fl oo rs

Re pl en ish

Su pp ly Di sp en se rs

Cl ea n/ Di sin fe ct Cl ea n

Gl as s, M irr or s, an d

Fix tu re s

3.1 3.2 3.3 Operational Areas (nonoperational equipment/fixtures) 1,639 0 1,639 2D7 - - D7 W M - - D7 Q - - D7 D7 D7 Shared Office Space 1,462 0 1,462 D7 - - D5 W Q Q Q D5 Q - - - D5 W Single Occupancy Office Space 1,854 0 1,854 D5 - - W W Q Q Q W Q - - - W W Conference Rooms 806 0 806 D5 - - D5 W Q M Q D5 Q - - - D5 W Reception Areas/Lobbies 60 288 348 D7 - - D7 W Q W Q D7 Q D7 Q D7 D7 D7 Corridors, Hallways 866 480 1,346 D7 - - D7 W - W Q D7 Q D7 Q - D7 W All Breakrooms/Kitchens/Queue Lines 0 759 759 2D7 - - 2D7 W M M Q - - 2D7 Q 2D7 2D7 D7 Locker Rooms 233 115 348 D7 - - D7 W Q - - D7 Q D7 Q D7 D7 D7 All Mechanical Rooms 0 2,504 2,504 D7 - - - - - - - - - Q - - - - All Equipment Rooms 3,593 0 3,593 D7 - - - - - - - Q - - - - - - Janitor Closets/Areas/Rooms 0 108 108 D7 - - W - - - - - - W Q W W W All Restrooms 0 789 789 2D7 - - 2D7 W - M Q - - 2D7 Q 2D7 2D7 2D7 Guard House 0 150 150 2D7 - - D7 M Q M Q - - D7 Q D7 D7 D7 Elevator 54 0 54 2 - - - D7 M - - - D7 Q - - - D7 D7 Showers 2 D7 - - - - - - - - - D7 - D7 D7 D7 High-Use Stairwells (Frequent/Daily Use) - # of Levels 5 - - - D7 M - - - - - D7 - - D7 D7 Low-Use Stairwells (Infrequent Use) - # of Levels 23 - - - W M - - - - - W - - W - Appliances (stove/microwave/refrigerator/ice maker) 31 - - - D7 - - - - - - - - - D7 D7 Refrigerators Interior (Total # of refrigerators) 10 - - - - - - - - - - - - - M - Drinking Fountains/Bottle Fill Stations 7 - - - - - - - - - - - - - 2D7 2D7 HVAC air registers/grilles/diffusers - - - M Q - - - - - - - - - - Dumpster Area - D7 - - - - - - - - - - - - - Sidewalks/Grounds D7 D7 D7 - - - - - - - - - - - - Rugs and Mats - - - - - - - - D7 Q - - - - - Estimated Sq. Ft. Totals 10,567 5,193 15,760

Chart Key D7 = 1x Day, 7 Days/Wk 2D7 = 2x Day, 7 Days/Wk 3D7 = 3X Day, 7 Days/Wk D5 = 1x Day, 5 Days/Wk W = Once Weekly M = Once Monthly Q = Quarterly SA = Semi-Annually (Twice a Year)

Total Restrooms* Quantity Toilets Urinals Avg. Per Restroom

Total Sq Ft

Single Use Restroom 2 1 0 24 48 Multi-Use Medium Restroom 3 2-3 0-2 119 357 Multi-Use Large Restroom 3 4 + 3 + 128 384

3.7 MultiSOW Reference

Total Est. Sq. Ft.

3.4

Est. Square Feet

3.5 3.6

File details come from the government source that posted it. Updated .