J-2 BGR ATCT TRACON Janitorial Frequency Chart.pdf
PDF 128 KB Posted
- Solicitation number
- 697DCK-26-R-00005
About this file
This document is a detailed Statement of Work (SOW) for cleaning services at the Bangor ATCT and TRACON BGR ATCT facility located at 85 Tower Rd, Bangor, ME 04401. The facility operates 24/7, with cleaning to be performed from 5 PM - 9 PM, and encompasses various areas including operational spaces, office spaces, restrooms, mechanical rooms, and exterior areas. The cleaning matrix specifies different frequencies for various cleaning tasks across multiple spaces, ranging from daily (7 days a week) to quarterly cleaning, with specific attention to different flooring types (carpeted and uncarpeted). The total facility area is approximately 3,779 square feet, with cleaning requirements tailored to each specific area, including tasks such as surface dusting, vacuuming, window cleaning, floor maintenance, and disinfection.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 697DCK-26-R-00005 Amendment 1 jlh.pdf | ||
| Wage Determination 2015-4001 Rev. 29 12-12-2024.pdf | ||
| J-1 Bangor SoW.pdf | ||
| J-5 Contractor Staffing Access Questionnaire.pdf | ||
| 697DCK-26-R-00005.pdf | ||
| J-3 Pricing Proposal Spreadsheet.xlsx | XLSX spreadsheet | |
| J-4 Customer Satisfaction Survey.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Name & Ident of Facility: Bangor ATCT and TRACON BGR ATCT Address: 85 Tower Rd, Bangor ME 04401 Facility Operating Hours: 24x7 Timeframe to clean Operational Area(s) 5 PM - 9 PM
General Frequency Non-24/7 Facilities
Occupancy <25
Flo or in g T yp e
Sq ua re Fo ot ag e (cu m ul at ive
Ite m C ou nt
W as te /R ec yc le Re ce pt ac les
Po lic in g G ro un ds Sm ok in g R ec ep ta cle s
Su rfa ce D us tin g & C lea ni ng Hi gh Su rfa ce
D us tin g &
C lea ni ng
Va cu um /P ol ish
Fu rn itu re
W in do ws
W in do w C ov er s Va cu um
C ar pe te d Flo or s, Ru gs
M at s
Sh am po o/
St ea m C lea n
Ca rp et s, Ru gs
M at s
Cl ea n/ M op U nc ar pe te d Flo or s
Cl ea n/ St rip /W ax /B uf f
Un ca rp et ed Fl oo rs
Re pl en ish
Su pp ly Di sp en se rs
Cl ea n/ Di sin fe ct Cl ea n
Gl as s, M irr or s, an d
Fix tu re s
3.1 3.2 3.3 3.4 3.4 3.4 3.5 3.5 3.6 3.6 3.7 3.7 3.9/3.11 Multi Multi Operational Areas (nonoperational equipment/fixtures) C 712 D7 - - D7 W M - - D7 Q D7 D7 D7 Shared Office Space C 522 D7 - - D3 W Q W Q D3 Q - D5 W Single Occupancy Office Space C 630 D7 - - W W Q W Q W Q - W W Conference Rooms C 300 D7 - - D3 W Q W Q D3 Q - D3 W Reception Areas/Lobbies UC 150 D7 - - D3 W Q D3 Q D3 Q D3 D3 D3 Corridors, Hallways UC 978 D7 - - D3 W - W Q D3 Q - D3 W All Breakrooms/Kitchens/Queue Lines UC 195 D7 - - D7 W M W Q D7 Q D7 D7 D7 All Mechanical Rooms UC 162 D7 - - - - - - - Q - - - - All Equipment Rooms UC 185 D7 - - - - - - Q - - - Janitor Closets/Areas/Rooms UC 98 D7 - - W - - W Q W Q W W W All Restrooms UC 296 D7 - - D7 W - W Q - - D7 Q D7 D7 D7 Smoking Area/Shelter - Gazebo Outside UC 100 D7 D3 D3 D3 - Elevator UC 40 1 - - - D3 M - - - D3 Q - D3 D3 Low-Use Stairwells (Tower Shaft/Egress) UC 4 - - - W M - - - W - - W - Appliances 9 - - - D7 - - - - - - - - - D7 D7 Refrigerators Interior 3 - - - - - - - - - - - - - M - Drinking Fountains/Bottle Fill Stations 1 - - - - - - - - - - - - - D7 D7 HVAC air registers/grilles/diffusers - - - M Q - - - - - - - - Q - Dumpster Area - D7 - - - - - - - - - - - - - Sidewalks/Grounds D7 D5 D5 - - - - - - - - - - - - Rugs and Mats - - - - - - - - D3 Q - - - - -
Chart Key D7 = 1x Day, 7 Days/Wk D3 = 1xDay, 3 Days/Wk 2D7 = 2x Day, 7 Days/Wk 3D7 = 3X Day, 7 Days/Wk D5 = 1x Day, 5 Days/Wk W = Once Weekly M = Once Monthly Q = Quarterly SA = Semi-Annually (Twice a Year)
Carpeted C Uncarpeted (i.e. tile, linoleum, concrete) UC
Total Restrooms
Quantity
Average Sq Ft Per Restroom
Total Sq Ft
Single Use Restroom 1 40 40 Multi-Use Medium Restroom 2 128 256 Multi-Use Large Restroom Total Square Feet 296
Flooring Types
SOW Reference
N24x7 <25_BRG ATCT TRACON
File details come from the government source that posted it. Updated .