This solicitation requests proposals for a major improvement project at the Fort Lauderdale International Airport Air Traffic Control Tower facility. Offerors must be registered in the System for Award Management and submit proposals in accordance with the solicitation instructions. A virtual site visit will be held on July 15, 2020, with questions due by July 20th and proposals due August 3rd. The project involves the Federal Aviation Administration facility located at Fort Lauderdale International Airport.
View the file
Other files
Show all 24
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
FO
TNEMT
R A
P E
D
N
OI
T
AT
RO
PSNART
U N
IT
E
D
STATES OF
AM
ER
I C A
COVER SHEET
GENERAL
G000
JANUARY 31, 2020
FT. LAUDERDALE, FL.
FORT LAUDERDALE INTERNATIONAL
MAJOR IMPROVEMENTS
AIRPORT TRAFFIC CONTROL TOWER
CRK
RAB
CRK
FEDERAL AVIATION ADMINISTRATION
DEPARTMENT OF TRANSPORTATION
DESCRIPTION
DATE
APPROVED
PAGE OF
REVIEWED BY
SUBMITTED BY APPROVED BY
ISSUED BY DATE
DRAWING NO REV
DESIGNED
DRAWN
CHECKED
REV JCN
DATE
REDLINE
APVD
JCN
wileywilson.com
678.320.1888
Atlanta, Georgia 30328-6055
Bldg. C, Ste 515
5901 Peachtree Dunwoody Rd.
Wiley|Wilson
SUBMITTER'S TITLE - CIVIL ENGINEER APPROVER'S TITLE - MANAGER
SCALES SHOWN FOR 22" X 34" SHEET. ADJUST SCALES FOR OTHER SIZES.
FT LAUDERDALE (INTERNATIONAL) FL
FLL-D-TOWB-
1508912
CENTER
ENGINEERING
ATLANTA TERMINAL
WW JOB NUMBER: 219075.00
MAJOR IMPROVEMENTS
FORT LAUDERDALE AIRPORT TRAFFIC CONTROL TOWER
JAN 31, 2020
cknight Stamp
G001
TITLEDRAWING NUMBER
CRK
RAB
GENERAL
BASE BUILDING - DRAWING INDEX
FLL-D-TOWB-H001
FLL-D-TOWB-G040
FLL-D-TOWB-G015
FLL-D-TOWB-G011
FLL-D-TOWB-G010
FLL-D-TOWB-G002
FLL-D-TOWB-G001
FLL-D-TOWB-G000
HAZARDOUS MATERIALS
CONSTRUCTION COORDINATION NOTES
SYMBOL LEGEND
ABBREVIATIONS - SHEET 2
ABBREVIATIONS - SHEET 1
ATCT - DRAWING INDEX
BASE BUILDING - DRAWING INDEX
COVER SHEET
GENERAL
BASE BUILDING (TRACON)
FLL-D-TRACO-G000
DEMOLITION
ARCHITECTURAL
MECHANICAL
PLUMBING
ELECTRICAL
FIRE PROTECTION
GENERATOR BUILDING PLAN
BASE BUILDING AND LINK PLAN
FLL-D-TRACO-F102
FLL-D-TRACO-F101
FLL-D-TRACO-A610
FLL-D-TRACO-A505
FLL-D-TRACO-A500
FLL-D-TRACO-A410
FLL-D-TRACO-A401
FLL-D-TRACO-A400
FLL-D-TRACO-A140
FLL-D-TRACO-A100
FLL-D-TRACO-A000
ROOF DETAILS
DOOR TYPES, SCHEDULE AND DETAILS
FINISH AND COLOR SCHEDULES
SCREENED-IN PORCH
RESTROOM ACCESSORIES
RESTROOM DEMOLITION AND NEW WORK
BASE BUILDING ROOF PLAN
BASE BUILDING FLOOR PLAN
LEGEND, SYMBOLS AND GENERAL NOTES
FLL-D-TRACO-P400
FLL-D-TRACO-P100
FLL-D-TRACO-P050
FLL-D-TRACO-P000
DETAILS
DETAILS
PANEL SCHEDULES
PANEL SCHEDULES
PANEL SCHEDULES
BASE BUILDING ROOF LIGHTNING PROTECTION PLAN
BASE BUILDING POWER PLAN
GENERATOR BUILDING PLAN
ELECTRICAL SITE PLAN
GENERAL NOTES
LEGEND AND SYMBOLS
FLL-D-TRACO-E601
FLL-D-TRACO-E600
FLL-D-TRACO-E502
FLL-D-TRACO-E501
FLL-D-TRACO-E500
FLL-D-TRACO-E160
FLL-D-TRACO-E120
FLL-D-TRACO-E060
FLL-D-TRACO-E050
FLL-D-TRACO-E001
FLL-D-TRACO-E000
FLL-D-TRACO-D501
FLL-D-TRACO-D500
FLL-D-TRACO-D401
FLL-D-TRACO-D400
FLL-D-TRACO-D301
FLL-D-TRACO-D300
FLL-D-TRACO-D140
FLL-D-TRACO-D100
FLL-D-TRACO-D000
FLL-D-TRACO-M802
FLL-D-TRACO-M801
FLL-D-TRACO-M800
FLL-D-TRACO-M602
FLL-D-TRACO-M601
FLL-D-TRACO-M600
FLL-D-TRACO-M500
FLL-D-TRACO-M420
FLL-D-TRACO-M400
FLL-D-TRACO-M100
FLL-D-TRACO-M000
SEQUENCE OF OPERATION AND SYSTEM POINT SYSTEM
CONTROL SYSTEM DIAGRAM FCU-1 AND FCU-2
CONTROL SYSTEM DIAGRAM AHU-1, VAV & EXHAUST FANS
HVAC DETAILS
HVAC DETAILS
HVAC DETAILS
HVAC SCHEDULES
ENLARGED MECHANICAL ROOM & SECTION
ENLARGED RESTROOM HVAC PLAN
BASE BUILDING FLOOR PLAN - HVAC
HVAC LEGEND AND GENERAL NOTES
ENLARGED RESTROOM NEW WORK AND SCHEDULE
BASE BUILDING FLOOR PLAN - NEW WORK
PLUMBING SITE PLAN
SYMBOLS AND GENERAL NOTES
ELECTRICAL - BASE BUILDING ROOF PLAN DEMOLITION
ELECTRICAL - BASE BUILDING FLOOR PLAN DEMOLITION
PLUMBING - ENLARGED RESTROOM DEMOLITION PLAN
PLUMBING - BASE BUILDING FLOOR PLAN - DEMOLITION
MECHANICAL - MECHANICAL ROOM BASE BUILDING PLAN - DEMOLITION
MECHANICAL - BASE BUILDING FLOOR PLAN - DEMOLITION
ARCHITECTURAL - BASE BUILDING ROOF PLAN DEMOLITION
ARCHITECTURAL - BASE BUILDING FLOOR PLAN DEMOLITION
PLUMBING - SITE PLAN - DEMOLITION
FEDERAL AVIATION ADMINISTRATION
DEPARTMENT OF TRANSPORTATION
DESCRIPTION
DATE
APPROVED
PAGE OF
REVIEWED BY
SUBMITTED BY APPROVED BY
ISSUED BY DATE
DRAWING NO REV
DESIGNED
DRAWN
CHECKED
REV JCN
DATE
REDLINE
APVD
JCN
wileywilson.com
678.320.1888
Atlanta, Georgia 30328-6055
Bldg. C, Ste 515
5901 Peachtree Dunwoody Rd.
Wiley|Wilson
SUBMITTER'S TITLE - CIVIL ENGINEER APPROVER'S TITLE - MANAGER
SCALES SHOWN FOR 22" X 34" SHEET. ADJUST SCALES FOR OTHER SIZES.
FT LAUDERDALE (INTERNATIONAL) FL
FLL-D-TOWB-
1508912
CENTER
ENGINEERING
ATLANTA TERMINAL
WW JOB NUMBER: 219075.00
MAJOR IMPROVEMENTS
FORT LAUDERDALE AIRPORT TRAFFIC CONTROL TOWER
JAN 31, 2020
G002
RAB
DRAWING NUMBER TITLE
ATCT
FLL-D-ATCT-G000
DEMOLITION
ARCHITECTURAL
MECHANICAL
ELECTRICAL
FIRE PROTECTION
ATCT - DRAWING INDEX
GENERAL
FLL-D-ATCT-A611
FLL-D-ATCT-A610
FLL-D-ATCT-A505
FLL-D-ATCT-A500
FLL-D-ATCT-A121
FLL-D-ATCT-A103
FLL-D-ATCT-A102
FLL-D-ATCT-A101
FLL-D-ATCT-A100
FLL-D-ATCT-A000
FLL-D-ATCT-F501
FLL-D-ATCT-F103
FLL-D-ATCT-F102
FLL-D-ATCT-F101
DETAILS
SUBJUNCTION LEVEL 1 AND JUNCTION LEVEL PLANS
CABLE ACCESS (TYPICAL) AND SUBJUNCTION LEVEL 2 PLANS
GROUND LEVEL AND CABLE ACCESS LEVEL 1 PLANS
FLL-D-ATCT-D501
FLL-D-ATCT-D500
FLL-D-ATCT-D400
FLL-D-ATCT-D301
FLL-D-ATCT-D300
FLL-D-ATCT-D103
FLL-D-ATCT-D102
FLL-D-ATCT-D101
FLL-D-ATCT-D100
PANEL SCHEDULES
PANEL SCHEDULES
CAB LEVEL ROOF PLAN - LIGHNING PROTECTION
SUBJUNCTION LEVEL 1 AND JUCTION LEVEL - NEW WORK
SUBJUNCTION LEVEL 2 POWER PLAN - NEW WORK
GROUND LEVEL POWER PLAN - NEW WORK
FLL-D-ATCT-E501
FLL-D-ATCT-E500
FLL-D-ATCT-E160
FLL-D-ATCT-E122
FLL-D-ATCT-E121
FLL-D-ATCT-E120
PLUMBING
FLL-D-ATCT-P400
CONTROL SYSTEM DIAGRAM FOR FCU-T2 AND FCU-T3
SEQUENCE OF OPERATION AND SYSTEM POINT SYSTEM
CONTROL SYSTEM DIAGRAM FOR AHUs-T1/T1B, T4/T4B
HVAC SCHEDULES
SUBJUNCTION LEVEL 1 AND JUNCTION LEVEL - HVAC
GROUND LEVEL AND SUBJUNCTION LEVEL 2 - HVAC
FLL-D-ATCT-M802
FLL-D-ATCT-M801
FLL-D-ATCT-M800
FLL-D-ATCT-M500
FLL-D-ATCT-M101
FLL-D-ATCT-M100
GROUND LEVEL PLAN - NEW WORK
ELECTRICAL - SUBJUNCTION LEVEL 1 AND JUNCTION LEVEL DEMOLITION
ELECTRICAL - GROUND LEVEL AND SUBJUNCTION LEVEL 2 DEMOLITION
PLUMBING - GROUND LEVEL PLAN - DEMOLITION
MECHANICAL - SUBJUNCTION LEVEL 1 AND JUNCTION LEVEL DEMOLITION
MECHANICAL - GROUND LEVEL AND SUBJUNCTION LEVEL 2 DEMOLITION
ARCHITECTURAL - CAB FLOOR AND ROOF PLANS DEMOLITION
ARCHITECTURAL - SUBJUNCTION LEVEL 1 AND JUNCTION LEVEL DEMOLITION
ARCHITECTURAL - CABLE ACCESS PLAN AND SUBJUNCTION LEVEL 2 DEMOLITION
ARCHITECTURAL - GROUND LEVEL AND SECOND LEVEL DEMOLITION
CATWALK HATCH AND CAB DETAILS
CATWALK AND CAB ROOF DETAILS
DOOR TYPES, SCHEDULE AND DETAILS
FINISH SCHEDULE AND COLOR SELECTIONS
CABLE ACCESS 7TH LEVEL - RCP
CAB LEVEL FLOOR AND ROOF PLANS
SUBJUNCTION LEVEL 1 AND JUNCTION LEVEL
CABLE ACCESS PLAN AND SUBJUNCTION LEVEL 2
GROUND LEVEL AND SECOND LEVEL PLAN
LEGEND, SYMBOLS AND GENERAL NOTES
FEDERAL AVIATION ADMINISTRATION
DEPARTMENT OF TRANSPORTATION
DESCRIPTION
DATE
APPROVED
PAGE OF
REVIEWED BY
SUBMITTED BY APPROVED BY
ISSUED BY DATE
DRAWING NO REV
DESIGNED
DRAWN
CHECKED
REV JCN
DATE
REDLINE
APVD
JCN
wileywilson.com
678.320.1888
Atlanta, Georgia 30328-6055
Bldg. C, Ste 515
5901 Peachtree Dunwoody Rd.
Wiley|Wilson
SUBMITTER'S TITLE - CIVIL ENGINEER APPROVER'S TITLE - MANAGER
SCALES SHOWN FOR 22" X 34" SHEET. ADJUST SCALES FOR OTHER SIZES.
FT LAUDERDALE (INTERNATIONAL) FL
FLL-D-TOWB-
1508912
CENTER
ENGINEERING
ATLANTA TERMINAL
WW JOB NUMBER: 219075.00
MAJOR IMPROVEMENTS
FORT LAUDERDALE AIRPORT TRAFFIC CONTROL TOWER
JAN 31, 2020
ABBREVIATIONS - SHEET 1
G010
COL COLUMN
CO CLEANOUT, CONDUIT ONLY
CMU CONCRETE MASONRY UNIT
CM COMMUNICATION MANHOLE
CLR CLEAR
CLG CEILING
CLF CURRENT LIMITING FUSE
CL CENTERLINE
CKT CIRCUIT
C.I.P. CAST IN PLACE
CWS CHILLED WATER SUPPLY
CWR CHILLED WATER RETURN
CWP CHILLED WATER PUMP
CHWS CHILLED WATER SUPPLY
CHWR CHILLED WATER RETURN
CHW CHILLED WATER
CHKD CHECKERED
CH CHILLER
CFM CUBIC FEET PER MINUTE
CFACC CENTRIFUGAL FAN AIR COOLED CONDENSER
CF CUBIC FOOT/FEET
CAF COMBUSTION AIR FAN
CENTRIF CENTRIFUGAL
CENT CENTRIFUGAL
CD CEILING DIFFUSER, CONDENSATE DRAIN
CCTV CLOSED CIRCUIT TELEVISION
CBCR CURVED BLADE CEILING REG.
CB CIRCUIT BREAKER
CAV CONSTANT AIR VOLUME
CAP CAPACITY
C CONDUIT
C
BTUH BRITISH THERMAL UNIT/HOUR
BTU BRITISH THERMAL UNIT
BSMT BASEMENT
BSDC BARE SOFT DRAWN COPPER
BPU BREAKER PROGRAMMING UNIT
BP BOOSTER PUMP
BOT BOTTOM
BOP BOTTOM OF PIPING
BOF BOTTOM OF FIXTURE
BOD BOTTOM OF DUCT, BACKDRAFT DAMPER
BLK BLACK
BLDG BUILDING
BITS BYPASS ISOLATION TRANSFER SWITCH
BI BACKWARD INCLINED
BFP BACKFLOW PREVENTER
BFC BELOW FINISHED CEILING
BF BELOW FLOOR (PIPE SIZE)
BDD BACKDRAFT DAMPER
BCKP BACKUP
BC BARE COPPER
BBHWH BASEBOARD HOT WATER HEATER
BAT CHGR BATTERY CHARGER
B
AWS AMERICAN WELDING SOCIETY
AWG AMERICAN WIRE GAUGE
AVG AVERAGE
AV AUTOMATIC VENT
AUX AUXILIARY
ATV ATMOSPHERIC VENT
ATS AUTOMATIC TRANSFER SWITCH
ATCT AIRPORT TRAFFIC CONTROL TOWER
ATC AIR TRAFFIC CONTROL
ATC ACOUSTICAL TILE CEILING
ATBM AIRWAY/TERMINAL BUILDING MAINTENANCE FACILITY
AT AMPERE TRIP
ASME AMERICAN SOCIETY OF MECHANICAL ENGINEERS
AND AIR CONDITIONING ENGINEERS
ASHRAE AMERICAN SOCIETY OF HEATING, REFRIGERATION
A/S AUDIBLE STROBE
AS AIR SEPARATOR
ARTS AUTOMATED RADAR
ARCH ARCHITECT, ARCHITECTURAL
APPROX APPROXIMATELY
APD AIR PRESSURE DROP
AP ANNUNCIATOR POINT, ACCESS PANEL
AO ANALOG OUTPUT
ANSI AMERICAN NATIONAL STANDARDS INSTITUTE
ANN ANNUNCIATOR
AMM AMMETER
ALUM ALUMINUM
AL-GL ALUMINUM AND GLASS
AL AIRPORT LIGHTING, ALUMINUM
AISC AMERICAN INSTITUTE OF STEEL CONSTRUCTION
AIC AMPERE INTERRUPTING CAPACITY
AI ANALOG INPUT
AHU AIR HANDLING UNIT
AH AIR HANDLER
AFR ABOVE FINISHED ROOF
AFG ABOVE FINISHED GRADE
AFF ABOVE FINISHED FLOOR
AF AMPERE FRAME
ADJ ADJUSTABLE
AD ACCESS DOOR, AREA DRAIN
ACT ACOUSTICAL CEILING TILE, ACCESS CONTROL TERMINAL
ACM ASBESTOS CONTAINING MATERIAL
ACI AMERICAN CONCRETE INSTITUTE
ACDFC AIR COOLED DRY FLUID COOLER
ACC AIR COOLED CHILLER
A/C AIR CONDITIONING
AC ALTERNATING CURRENT, ABOVE CEILING
ABG ABOVE FINISHED GRADE
AAV AUTOMATIC AIR VENT
AA AIR COOLED
A AMPERE
A
EXP EXPOSED, EXPANSION
EXIST EXISTING
EXH EXHAUST
EWT ENTERING WATER TEMPERATURE
EWH ELECTRIC WALL HEATER, ELECTRIC WATER HEATER
EWC ELECTRICAL WATER COOLER
EW EACH WAY
EUH ELECTRIC UNIT HEATER
ET EXPANSION TANK
ESP EXTERNAL STATIC PRESSURE
ERMS ENVIRONMENTAL REMOTE MONITORING SYSTEM
ER EXHAUST REGISTER
EQUIP EQUIPMENT
EQ EQUAL
ENT ENTERING
EMT ELECTRICAL METALLIC TUBING
EMS ENERGY MANAGEMENT SYSTEM
EMI ELECTROMAGNETIC INTERFACE
EMERG EMERGENCY
EMCS ENERGY MANAGEMENT AND CONTROL SYSTEM
ELEV, EL ELEVATION, ELEVATOR
ELEC ELECTRIC
EIFS EXTERIOR INSULATION FINISH SYSTEM
EHC ELECTRIC HEATING COIL
EH ELECTRIC HEATER, ELECTRONIC HUMIDIFIER
EMERGENCY GENERATOR
EG, E/G ENGINE GENERATOR, EXHAUST GRILLE
EF EXHAUST FAN
EDH ELECTRIC DUCT HEATER
EDAM ELECTRICAL DATA ACQUISITION AND MONITORING
ECP ENGINE CONTROL PANEL
EAT ENTERING AIR TEMPERATURE
EA EACH, EXHAUST AIR
E EAST
E
DWL DOWEL
DWGS DRAWINGS
DWDI DOUBLE WIDTH DOUBLE INLET
DWBP DOMESTIC WATER BOOSTER PUMP
DTS DOUBLE THROW SWITCH
DT DOUBLE THROW, DIAPHRAM TANK
DSF DESTRATIFICATION FAN
DPT DIFFERENTIAL PRESSURE TRANSMITTER
DPST DOUBLE POLE SINGLE THROW
D PNL DISTRIBUTION PANEL
DPDT DOUBLE POLE DOUBLE THROW
DP DIFFERENTIAL PRESSURE
DO DIGITAL OUTPUT
DN DOWN
DM DEMAND METER
DF DEGREES FAHRENHEIT
DISC DISCONNECT
DIM DIMENSION
DIFF DIFFUSER
DIAG DIAGONAL
DIA DIAMETER
DI DIGITAL INPUT
DHW DOMESTIC HOT WATER
DG DOOR GRILLE
DET DETAIL
DEMO DEMOLITION
DEG DEGREE
DDC DIRECT DIGITAL CONTROL
DC DIRECT CURRENT
DBL DOUBLE
DB DRY BULB, DIRECT BURIAL, DUCTBANK
DAMP DAMPER
D DRAIN
D
CY YD CUBIC YARD
CWV COMBINATION WASTE AND VENT
CWS CONDENSER WATER SUPPLY
CWR CONDENSER WATER RETURN
CWP CONDENSER WATER PUMP, CHILLED WATER PUMP
CW COLD (DOMESTIC) WATER
CVC CENTRAL VACUUM CLEANER
CV CONSTANT VOLUME, CONTROL VALVE
CU FT CUBIC FOOT/FEET
CU CONDENSING UNIT, COPPER
CTL CONTROL
CURRENT TRANSFORMER, CERAMIC TILE
CT COOLING TOWER, CABLE TRAY,
CSF CHEMICAL SHOT FEEDER
CS CONTROL SWITCH
CR CONTROL RELAY
CPU CENTRAL PROCESSING UNIT
CPT CARPET
CPC CRITICAL POWER CENTER
COR CONTRACTING OFFICER'S REPRESENTATIVE
CONTR CONTRACTOR
CONT CONTINUATION
CONN CONNECTION
CONFIG CONFIGURATION
COND CONDENSATE
CONC CONCRETE
COMM COMMUNICATIONS
ISMS INTEGRATED SECURITY MANAGEMENT SYSTEM
INV INVERT
INT INTERIOR
INSUL INSULATED
INDIC INDICATOR
INCL INCLUDE
INCAND INCANDESCENT
IN INCHES
IE INVERT ELEVATION
IC INTERCOMMUNICATION, INTERCOM
I
HZ HERTZ
HX HEAT EXCHANGER
HWUH HOT WATER UNIT HEATER
HWS HOT WATER SUPPLY
HWR HOT WATER RETURN
HWP HOT WATER PUMP
HVAC HEATING, VENTILATION AND AIR CONDITIONING
HU HUMIDIFIER
HTR HEATER
HTG HEATING
HT HEIGHT
HSB HIGH STRENGTH BOLT
HS HIGH STRENGTH
HR HOUR
HPS HIGH PRESSURE SODIUM
HP HORSEPOWER
HORIZ HORIZONTAL
HOA HAND-OFF-AUTOMATIC
H. MET. HOLLOW METAL
HM HOLLOW METAL
HH HAND HOLE
HEX HEXAGONAL
HB HOSE BIBB
HAZMAT HAZARDOUS MATERIALS
H
GYP GYPSUM
GWB GYPSUM WALLBOARD
GUH GAS FIRED UNIT HEATER
GRS GALVANIZED RIGID STEEL
GRN GREEN
GPM GALLONS PER MINUTE
GPH GALLONS PER HOUR
GOVT GOVERNMENT
GND GROUND CONNECTOR
GFM GOVERNMENT FURNISHED MATERIAL
GFE GOVERNMENT FURNISHED EQUIPMENT
GFCI GROUND FAULT CIRCUIT INTERRUPTER
GEN GENERAL, GENERATOR
GALV GALVANIZED
GAL GALLON
GA GAUGE
G GROUND
G
FWD FORWARD, FIRE SPRINKLER WATER DRAIN
FWS FIRE WATER SUPPLY
FW FIRE WATER
FVC FIRE VALVE CABINET
FV FULL VOLTAGE
FTG FOOTING, FITTING
FT FEET
FSS FUSIBLE SAFETY SWITCH
FSD FIRE/SMOKE DAMPER
FS FLOW SWITCH, FLOOR SINK
FPU FIELD PROGRAMMING UNIT
FPM FEET PER MINUTE
FP FIRE PUMP
FOT FIBER OPTIC TERMINAL, FUEL OIL TRANSFER
FOS FUEL OIL SUPPLY
FOR FUEL OIL RETURN
FOG FUEL OIL GAGE
FOD FACE OPERATED DAMPER
FO FIBER OPTIC
FM FACTORY MUTUAL, FORCE MAIN
FLUOR FLUORESCENT
FLS FLOW SWITCH, FIRE AND LIFE SAFETY
FLEX FLEXIBLE
FLR FLOOR
FLA FULL LOAD AMPERES
FIN FINISH
FIG FIGURE
FHV FIRE HOSE VALVE
FHC FIRE HOSE CABINET
FH FIRE HYDRANT
FG FIBERGLASS
FFE FINISHED FLOOR ELEVATION
FF FLY FAN
FEC FIRE EXTINGUISHER CABINET
FE FIRE EXTINGUISHER
FDR FEEDER
FDN FOUNDATION
FDC FIRE DEPARTMENT CONNECTION
FD FLOOR DRAIN, FIRE DAMPER
FCV FLOW CONTROL VALVE
FCU FAN COIL UNIT
FCO FLOOR CLEANOUT
FC FACE OF CURB, FLEXIBLE CONNECTION
FACT FACTORY
FACP FIRE ALARM CONTROL PANEL
FAA FEDERAL AVIATION ADMINISTRATION
FA FIRE ALARM, FREE AREA, FAN COOLED, FRESH AIR
°F DEGREES FAHRENHEIT
F FIRE WATER SUPPLY
F
MVD MANUAL VOLUME DAMPER
MVA MEGAVOLT AMPERE
MV MANUAL VENT
MUW MAKE-UP WATER
MUA MAKE-UP AIR
MTL METAL
MTD MOUNTED
MPG MULTI-POINT GROUND
MOD MOTOR OPERATED DAMPER
MM MILLIMETER
MLO MAIN LUGS ONLY
MISC MISCELLANEOUS
MIN MINIMAL, MINUTE, MINIMUM
MIL ST MILITARY STANDARD
MIL THOUSANDTHS OF AN INCH
MH MANHOLE
MG MOTOR GENERATOR
MFR MANUFACTURER
MEMB MEMBRANE
MED MEDIUM
MECH MECHANICAL
MDT MAIN DISTRIBUTION TERMINAL
MDF MEDIUM DENSITY FIBERBOARD
MD MANUAL DAMPER
MCP MOTOR CIRCUIT PROTECTOR
MCM THOUSAND CIRCULAR MILLS
MCC MOTOR CONTROL CENTER
MCB MOLDED CASE BREAKER
MBP MAINTENANCE BYPASS PANEL
MBH THOUSAND BTU/HOUR
MAX MAXIMUM
MAINT MAINTENANCE
MAG MAGNETIC DOOR HOLD OPEN
M
LWT LEAVING WATER TEMPERATURE
LVL LEVEL
LV LOW VOLTAGE
LTG LIGHTING
LT LIQUID TIGHT
LSD LINEAR SLOT DIFFUSER
LS LIGHT STANDARD
LRG LINEAR RETURN GRILLE
LRAG LINEAR RETURN AIR GRILLE
LRA LOCKED ROTOR AMPERE
LP LOW POINT
LOSP LOCAL OPERATING STATUS PANEL
LONG LONGITUDINAL
LLV LONG LEG VERTICAL
LLH LONG LEG HORIZONTAL
LFS LIGHTING FIXTURE SCHEDULE
LF LINEAR FEET
LD LINEAR DIFFUSER
LBS POUNDS
LBR LINEAR BAR RETURN
LBG LINEAR BAR GRILLE
LBD LINEAR BAR DIFFUSER
LAT LEAVING AIR TEMPERATURE
L&S LOUVER AND SCREEN
L
KWH KILOWATT HOUR
KW KILOWATT
KVAR KILOVOLT AMPERES-REACTIVE
KVA KILOVOLT AMPERES
KV KILOVOLT
KCMIL THOUSAND CIRCULAR MILLS
KA KILOAMPERES
K
JT JOINT
JP JOCKEY PUMP
JB JUNCTION BOX
J
CRK
CRK
RAB
GENERAL
FEDERAL AVIATION ADMINISTRATION
DEPARTMENT OF TRANSPORTATION
DESCRIPTION
DATE
APPROVED
PAGE OF
REVIEWED BY
SUBMITTED BY APPROVED BY
ISSUED BY DATE
DRAWING NO REV
DESIGNED
DRAWN
CHECKED
REV JCN
DATE
REDLINE
APVD
JCN
wileywilson.com
678.320.1888
Atlanta, Georgia 30328-6055
Bldg. C, Ste 515
5901 Peachtree Dunwoody Rd.
Wiley|Wilson
SUBMITTER'S TITLE - CIVIL ENGINEER APPROVER'S TITLE - MANAGER
SCALES SHOWN FOR 22" X 34" SHEET. ADJUST SCALES FOR OTHER SIZES.
FT LAUDERDALE (INTERNATIONAL) FL
FLL-D-TOWB-
1508912
CENTER
ENGINEERING
ATLANTA TERMINAL
WW JOB NUMBER: 219075.00
MAJOR IMPROVEMENTS
FORT LAUDERDALE AIRPORT TRAFFIC CONTROL TOWER
JAN 31, 2020
ABBREVIATIONS - SHEET 2
G011
RGS RIGID GALVANIZED STEEL
RG RETURN GRILLE
RFI RADIO FREQUENCY INTERFERENCE
RF RETURN FAN
REV REVISION
RET RETURN
REQ'D REQUIRED
REINF REINFORCEMENT, REINFORCED
REG REGISTER
REF REFERENCE
RECT RECTIFIER, RECEPTACLE
RECP RECEPTACLE
REC'D RECEIVED
REC RECEPTACLE
REBAR REINFORCING STEEL BAR
RE RESIDENT ENGINEER
RDF RUBBER RAISED DISK FLOOR
RD ROOF DRAIN
RCP REINFORCED CONCRETE PIPE, REFLECTED CEILING PLAN
RB RUBBER BASE
RAR RETURN AIR REGISTER
RAG RETURN AIR GRILLE
RAD RADIUS
RACP REMOTE ACCESS CONTROL PANEL
RA RETURN AIR, REMOTE ANNUNCIATOR
R RED, RISER, RADIATOR, RADIUS, REFRIGERANT
R
QUA QUARTER
Q
PVMT PAVEMENT
PVC POLYVINYL CHLORIDE, POINT OF VERTICAL CURVATURE
PTAC PACKAGED TERMINAL AIR CONDITIONER
PT PRESSURE TRANSMITTER, PRESSURE-TEMPERATURE PORT
PSIG POUNDS PER SQ.IN. GAUGE
PSIA POUNDS PER SQ.IN. ABSOLUTE
PSI POUNDS PER SQ. INCH
PSF POUNDS PER SQ. FOOT
PS PRESSURE SWITCH
PRV PRESSURE REDUCING VALVE
PROP PROPELLER
PRSR PRESSURIZATION
PRMY PRIMARY
PRESS PRESSURE
PREFAB PREFABRICATED
PP POWER POLE, PATCH PANEL
POS POSITIVE, POSITION
P.O.C. POINT OF CONNECTION
PNL PANEL, PANELBOARD
PMB POWER MIXING BOX
PM POWER MANHOLE
PLYWD PLYWOOD
PLCS PLACES
PLBG PLUMBING
PL PLATE
PIU POWER INDUCTION UNIT
PI PRESSURE INDICATOR
PH ELECTRICAL PHASE
PFR PERFORATED FACE RETURN
PFD PERFORATED FACE DIFFUSER
PF POWER FACTOR
PD PRESSURE DROP
PCS POWER CONDITIONING SYSTEM
PCMS POWER CONTROL MONITORING SYSTEM
PCHWS PRIMARY CHILLED WATER SUPPLY
PCHWR PRIMARY CHILLED WATER RETURN
PCF POUNDS PER CUBIC FOOT
PB PULL BOX
PART PARTITION
PABX PRIVATE AUTOMATIC BRANCH EXCHANGE
P POLE, PAINT, PUMP
P
OZ OUNCES
OVHD OVERHEAD
OSCO OUTSIDE CLEANOUT
OSA OUTSIDE SUPPLY AIR
ORL OVERFLOW ROOF LEADER
ORD OVERFLOW ROOF DRAIN
OPP OPPOSITE
OPNG OPENING
OH OPPOSITE HAND, OVERHEAD
OE OPEN END
ODP OPEN DRIP PROOF
OD OUTSIDE DIAMETER, OVERFLOW DRAIN
OC ON CENTER
OBD OPPOSED BLADE DAMPER
OAF OUTSIDE AIR FAN
OA OUTSIDE AIR
O
NTS NOT TO SCALE
NTE NOT TO EXCEED
NOM NOMINAL
N.O. NORMALLY OPEN
NO NUMBER OF DESIGNATION
NK NECK
NIC NOT IN CONTRACT
NG NATURAL GAS
NFPA NATIONAL FIRE PROTECTION ASSOCIATION
NFHB NON-FREEZE HOSE BIB
NEMA NATIONAL ELECTRICAL MANUFACTURERS' ASSOCIATION
NEG NEGATIVE
NEC NATIONAL ELECTRIC CODE
N.C. NORMALLY CLOSED
NC NOISE CRITERIA
NA NOT APPLICABLE
N NORTH, NEUTRAL
N
IMPEDANCEZ
Z
WYE DELTADY-
WYEY
Y
TRANSDUCERXDCR
TRANSMITTERXMTR
TRANSFORMERXFMR
TRANSFERXFR
AUXILIARY RELAYX
X
WELDED WIRE FABRICWWF
WATERWTR
WATER TANKWT
WASHDOWN SUPPLY WATERWSW
WATER PRESSURE DROPWPD
WEATHERPROOF NEMA TYPE 3R OR EQUIVALENT, UON
SUBSCRIPT "WP" APPLIED TO ANY SYMBOL INDICATESWP
WIRE MESH SCREENWMS
WATT METERWM
WATER HAMMER ARRESTERWHA
WATER HEATER, WALL HEATER, WALL HYDRANTWH
WATER GAUGEWG
WALL CLEANOUTWCO
WATER COLUMN, WATER CLOSET, WALL COVERINGWC
WET BULBWB
WITHOUTW/O
WITHW/
WEST, WIDTH, WATTW
W
VENT THROUGH ROOFVTR
VESTIBLE PRESSURIZATION FANVPF
VOLTMETERVM
VARIABLE FREQUENCY DRIVEVFD
VESTIBULEVEST
VERTICALVERT
VENTILATIONVENT
VIDEO DISPLAY TERMINALVDT
VOLUME DAMPER - MANUALVD
VINYL COMPOSITE TILEVCT
VACUUM BREAKERVB
VARIABLE AIR VOLUMEVAV
VACUUMVAC
VOLT AMPERE, VOICE ALARMVA
VOLT, VOLTAGE, VENTV
V
UTILITYUTIL
UNINTERUPTIBLE POWER SUPPLYUPS,U
UNIFORM PLUMBING CODEUPC
UNLESS OTHERWISE NOTEDUON
UNLESS NOTED OTHERWISEUNO
UNFUSEDUNF
UNDERWRITER'S LABORATORYUL
UNIT HEATERUH
UNDERGROUND POWERUGP
UNDERGROUNDUG
UNDERCUTUC
UNIFORM BUILDING CODEUBC
U
GMR
RAB
CRK
GENERAL
TW TEMPERED WATER
TYP TYPICAL
TVSS TRANSIENT VOLTAGE SURGE SUPPRESSOR (GFM)
TV TELEVISION, TEMPERING VALVE
TTB TELEPHONE TERMINAL BOARD
TT TEMPERATURE TRANSMITTER
T°STAT THERMOSTAT
TSP TOTAL STATIC PRESSURE, TRAP SEAL PRIMER
TS TWO SPEED
TRACO TERMINAL RADAR APPROACH CONTROL BUILDING
TRBL TROUBLE CONDITION
TP TRAP PRIMER, TWISTER PAIR
TOWB ATCT AND ATTACHED BASE BUILDING
TOS,T/S TOP OF STEEL
TOD TOP OF DUCT
TOC TOP OF CONCRETE
THK THICK, THICKNESS
TG TRANSFER GRILLE
TERM TERMINAL
TEMP TEMPERATURE
TELCO TELEPHONE COMPANY
TEL TELEPHONE
TEF TOILET EXHAUST FAN
TD TIME DELAY, TRENCH DRAIN
TC TRIP COIL, TOTAL COOLING, TIME CLOCK
TB TERMINAL BOX, TERMINAL BOARD
T&P TEMPERATURE AND PRESSURE
T&B TOP AND BOTTOM
T TRANSDUCER
T
SYS SYSTEM
SYM SYMMETRICAL
SWSR SIDE WALL SUPPLY REGISTER
SWSI SINGLE WIDTH SINGLE INLET
SWR SIDEWALL REGISTER
SWGR SWITCHGEAR
SWG SIDEWALL GRILLE
SWBD SWITCHBOARD
SW SWITCH
SUSP SUSPENDED
SUBJ SUBJUNCTION
STRUCT STRUCTURAL
STP SHIELDED TWISTED PAIR
STL STEEL
STGP SIGNAL TRANSPORT GROUND PLANE
STD STANDARD
ST SHUNT TRIP
S/S START-STOP
SS STAINLESS STEEL
SRG SIGNAL REFERENCE GRID
SR SUPPLY REGISTER
SQ.FT. SQUARE FOOT/FEET
SQ SQUARE
SPVR SUPERVISORY CONDITION
SPT STATIC PRESSURE TRANSMITTER
SPST SINGLE POLE SINGLE THROW
SPF STAIRWELL PRESSURIZATION FAN
SPEC SPECIFICATION
SP STATIC PRESSURE(IN W.G.), SINGLE POLE, SUMP PUMP
SOV SHUT-OFF VALVE
NATIONAL ASSOCIATION
SMACNA SHEET METAL AND AIR CONDITIONING CONTRACTORS'
SIM SIMILAR
SHT SHEET
SHLD SHIELDED
SHDWN SHUT DOWN
SGL SINGLE
SG SUPPLY GRILLE
SF SQUARE FEET
SENS SENSIBLE
SECT SECTION
SEC SECONDARY
S.D. SUPPLY DIFFUSER
SD SPLITTER DAMPER STORM DRAIN, SMOKE DETECTOR
SCP SYSTEM CONTROL PANEL, SMOKE CONTROL PANEL
SCND SECONDARY
SCHWS SECONDARY CHILLED WATER SUPPLY
SCHWR SECONDARY CHILLED WATER RETURN
SCHWP SECONDARY CHILLED WATER PUMP
SCHED SCHEDULE
SCC SECURITY CONTROL CENTER
S.C. SOLID CORE
SC SPIN IN COLLAR WITH VOLUME DAMPER, SENSIBLE COOLING
SAN SANITARY
SA SUPPLY AIR
S SOUTH, STAIN COLOR, SANITARY
S
RV RELIEF VALVE
RTU ROOF TOP UNIT
RTN RETURN
RQMTS REQUIREMENTS
RPZ REDUCED PRESSURE ZONE
RPM ROTATIONS PER MINUTE, REVOLUTIONS PER MINUTE
RP BP REDUCED PRESSURE BACKFLOW PREVENTER
RO REVERSE OSMOSIS
RMS ROOT MEAN SQUARE
RML RADAR MICROWAVE LINK
RMH ROOF MOUNTED HOOD
RM ROOM
RL RAIN LEADER
FEDERAL AVIATION ADMINISTRATION
DEPARTMENT OF TRANSPORTATION
DESCRIPTION
DATE
APPROVED
PAGE OF
REVIEWED BY
SUBMITTED BY APPROVED BY
ISSUED BY DATE
DRAWING NO REV
DESIGNED
DRAWN
CHECKED
REV JCN
DATE
REDLINE
APVD
JCN
wileywilson.com
678.320.1888
Atlanta, Georgia 30328-6055
Bldg. C, Ste 515
5901 Peachtree Dunwoody Rd.
Wiley|Wilson
SUBMITTER'S TITLE - CIVIL ENGINEER APPROVER'S TITLE - MANAGER
SCALES SHOWN FOR 22" X 34" SHEET. ADJUST SCALES FOR OTHER SIZES.
FT LAUDERDALE (INTERNATIONAL) FL
FLL-D-TOWB-
1508912
CENTER
ENGINEERING
ATLANTA TERMINAL
WW JOB NUMBER: 219075.00
MAJOR IMPROVEMENTS
FORT LAUDERDALE AIRPORT TRAFFIC CONTROL TOWER
JAN 31, 2020
4 0 4 8
1/4" = 1'-0"
SCALE IN FEET
020 20 40
X
X
X
GRAPHIC SCALE
ARCHITECTURAL
GRAPHIC SCALE
ENGINEERING
AXXX
AXXX
GENERAL SYMBOL LEGEND:
SECTION LETTER
A
SECTION IS LOCATED
SHEET NUMBER WHERE
AXXX
DETAIL IS LOCATED
SHEET NUMBER WHERE
DETAIL NUMBER
ELEVATION IS LOCATED
SHEET NUMBER WHERE
ELEVATION NUMBER
* SCALE OR OTHER INFORMATION
AXXX
DETAIL NUMBER
DETAIL TITLE
SECTION CUT
ELEVATION
DETAIL 2
GENERAL NOTES
GENERAL
SYMBOL LEGEND
G015
TITLE OF PLAN, SECTION OR DETAIL
RAB
THE SHEET IS REDUCED IN SIZE.
USING THE APPROPRIATE BAR SCALE WHEN
USED FOR SCALING AT FULL SIZE AND FOR
(22" X 34" DRAWING SHEET SIZE) AND IS
THIS SCALE REFERS TO FULL SIZE DRAWING
VERIFY FIELD CONDITIONS PRIOR TO COMMENCING EACH PORTION OF THE WORK.3.
DO NOT SCALE DRAWINGS.2.
FOR ALL ABBREVIATIONS REFERENCE DRAWINGS G010 & G011.1.
IS LOCATED
PLAN, SECTION OR DETAIL
SHEET NUMBER WHERE
CRK
CRK
B-5 ROOM TAG
X-1 DOOR TAG
FEDERAL AVIATION ADMINISTRATION
DEPARTMENT OF TRANSPORTATION
DESCRIPTION
DATE
APPROVED
PAGE OF
WW JOB NUMBER: 219075.00 FLL-D-ATCT-
REVIEWED BY
SUBMITTED BY APPROVED BY
ISSUED BY DATE
DRAWING NO REV
DESIGNED
DRAWN
CHECKED
REV JCN
DATE
REDLINE
APVD
JCN
1508912
FL
wileywilson.com
678.320.1888
Atlanta, Georgia 30328-6055
Bldg. C, Ste 515
5901 Peachtree Dunwoody Rd.
Wiley|Wilson
SUBMITTER'S TITLE - CIVIL ENGINEER APPROVER'S TITLE - MANAGER
SCALES SHOWN FOR 22" X 34" SHEET. ADJUST SCALES FOR OTHER SIZES.
CENTER
ENGINEERING
ATLANTA TERMINAL
FT LAUDERDALE (INTERNATIONAL)
MAJOR IMPROVEMENTS
FORT LAUDERDALE AIRPORT TRAFFIC CONTROL TOWER
JAN 31, 2020
G040
CONSTRUCTION STAGING NOTES
CONSTRUCTION COORDINATION NOTES
CONSTRUCTION NOTES
CRK
CRK
WELDING EQUIPMENT SHALL NOT BE POWERED BY THE FACILITY ELECTRICAL SYSTEM. WELDING SHALL NOT BE PERMITTED IN FAA OCCUPIED AREA.3.
OFFICERS REPRESENTATIVE A MINIMUM OF 10 WORKING DAYS IN ADVANCE OF THE SHUTDOWN OR CUTOVER.
HOURS. PREPARATORY WORK SHALL BE COMPLETED PRIOR TO SHUTDOWN. CUTOVER WORK SHALL BE SCHEDULED AND COORDINATED WITH THE FAA CONTRACTING
SHUTDOWNS, CUTOVERS AND ANY TEMPORARY PROVISIONS FOR PLUMBING, MECHANICAL AND ELECTRICAL SYSTEMS SHALL BE ACCOMPLISHED AFTER NORMAL OPERATING 2.
OF THE FLYING PUBLIC. SEE SPECIAL NOTES ON SHEET M000 FOR ADDITIONAL REQUIREMENTS.
SUCH DAMAGE OR DISRUPTION OF POWER SHOULD OCCUR. THE LOSS OF THESE COMPUTERS AND EQUIPMENT FOR ANY AMOUNT OF TIME WILL JEOPARDIZE THE SAFETY
NEGLIGENCE SUCH AS, BUT NOT LIMITED TO, DISRUPTION OF POWER TO THE UNITS. INFORM THE FAA CONTRACTING OFFICERS REPRESENTATIVE IMMEDIATELY IF
RESPONSIBLE FOR THE CONTINUOUS PROTECTION OF THIS EQUIPMENT FROM PHYSICAL AND ELECTRICAL DAMAGE AS A RESULT OF INCIDENTAL OR ACCIDENTAL
EXISTING FAA AIR TRAFFIC COMPUTERS AND EQUIPMENT SHALL REMAIN OPERATIONAL THROUGHOUT THE DURATION OF THIS CONTRACT. THE CONTRACTOR SHALL BE 1.
G. EQUIPMENT PROTECTION
FAA CONTRACTING OFFICERS REPRESENTATIVE.
CONCRETE SAWING, GRINDING, CORE DRILLING, CONCRETE DEMOLITION AND ANCHOR DRILLING WILL BE ALLOWED ONLY AT PREARRANGED TIMES APPROVED BY THE 3.
SEE CONSTRUCTION SEQUENCE NOTES FOR FURTHER INFORMATION.2.
CONSTRUCTION IN ADVANCE WITH THE FAA CONTRACTING OFFICERS REPRESENTATIVE.
IN AREAS ADJACENT TO THE AIR TRAFFIC CONTROL FUNCTION MUST BE ACCOMPLISHED AFTER NORMAL OPERATING HOURS. COORDINATE NIGHT WORK AND OVERTIME
THE CONTRACTOR SHALL NOT INTERFERE WITH THE AIR TRAFFIC CONTROL FUNCTION OF THE FACILITY. DEMOLITION NOISE, CONSTRUCTION NOISE AND ALL WORK 1.
F. DEMOLITION AND CONSTRUCTION HOURS
A FIRE OR LIFE SAFETY HAZARD.
REMOVE ALL CONSTRUCTION AND/OR DEMOLITION DEBRIS FROM THE JOB SITE TO MAINTAIN A CLEAN AND SAFE ENVIRONMENT AND TO PREVENT THE POSSIBILITY OF 2.
DUMPSTERS SHALL BE KEPT CLEAN AND FREE OF DEBRIS AND DUST DURING CONSTRUCTION. DEBRIS SHALL BE REMOVED BY THE CONTRACTOR IN A TIMELY MANNER.
ENCLOSED DUMPSTERS FOR DISPOSAL OF CONSTRUCTION DEBRIS SHALL BE PROVIDED BY THE CONTRACTOR WITHIN THE STAGING AREA. THE AREAS AROUND THE 1.
E. CONSTRUCTION DEBRIS
UNDERGROUND UTILITIES MAY RUN THROUGH THE STAGING AREA AND ELSEWHERE.
SHALL NOT PERFORM ANY DIGGING WITHOUT PERMISSION FROM THE FAA CONTRACTING OFFICERS REPRESENTATIVE. BURIED CABLES AND OTHER EXISTING
STORED AND PROTECTED. A CONSTRUCTION FENCE SHALL BE PROVIDED AT THE DISCRETION OF THE FAA CONTRACTING OFFICERS REPRESENTATIVE. CONTRACTOR
STORAGE OF CONSTRUCTION MATERIALS AND TRAILERS ON THE SITE SHALL BE LIMITED TO THE CONSTRUCTION STAGING AREA. MATERIALS SHALL BE NEATLY 1.
D. CONSTRUCTION MATERIAL STORAGE
EGRESS.
THE BUILDING IS A SECURE AREA, AND CONSTRUCTION PERSONNEL SHALL REMAIN IN THE CONSTRUCTION AREAS. CONTRACTOR SHALL MINIMIZE INGRESS AND 2.
BE IDENTIFIED AS SUCH. EACH CONSTRUCTION EMPLOYEE SHALL CHECK IN AND OUT UPON ENTERING AND LEAVING THE SITE.
THOSE CONSTRUCTION PERSONNEL. CONTRACTOR SHALL BE RESPONSIBLE FOR THE CONDUCT OF CONTRACTOR'S PERSONNEL ON SITE. CONTRACTOR VEHICLES SHALL
PERIMETER GATE. CONTRACTOR TO COORDINATE WITH HIS SUBS AND EMPLOYEES THE ACCESS TO THE FACILITY. TEMPORARY SECURITY BADGES MAY BE ISSUED TO
REQUIRED TO OBTAIN AN FAA CONTRACTOR BADGE PRIOR TO THE START OF WORK. A FACILITY ACCESS CARD WILL BE ISSUED AND WILL ALLOW ACCESS TO THE
AN ADVANCE LIST OF THE CONTRACTOR'S PERSONNEL SHALL BE PROVIDED TO THE FAA CONTRACTING OFFICERS REPRESENTATIVE. CONTRACTOR SUPERINTENDENT IS 1.
C. FAA SECURITY REQUIREMENTS
SIGNS AS NECESSARY TO RESERVE AN AREA FOR CONSTRUCTION PARKING ONLY.
CONTRACTOR'S STAGING AND PERSONNEL PARKING IS LIMITED AND SHALL BE DETERMINED AT THE PRECONSTRUCTION CONFERENCE. CONTRACTOR SHALL PROVIDE 1.
B. CONTRACTOR STAGING AREA AND PARKING
SHIFT CHANGES TO AVOID CONGESTION.
DELIVERIES SHALL BE SCHEDULED 48 HOURS IN ADVANCE WITH THE FAA CONTRACTING OFFICERS REPRESENTATIVE AND AT TIMES OTHER THAN THE FAA EMPLOYEE 1.
A. CONSTRUCTION ACCESS
STAGING AREA MUST BE COORDINATED WITH SITE PERSONNEL VIA THE FAA CONTRACTING OFFICERS REPRESENTATIVE.
CONSTRUCTION ACCESS (VEHICLE, PEDESTRIAN AND DELIVERIES), CONTRACTOR'S PARKING, CONSTRUCTION OFFICES AND THE EXTENT/SIZE OF THE CONSTRUCTION
PARAPHRASE OR SUPPLEMENT DIVISION 1 REQUIREMENTS AND ARE NOT INTENDED TO REPLACE DIVISION 1 REQUIREMENTS.
THE FOLLOWING NOTES REPRESENT MANY OF THE MAJOR REQUIREMENTS STATED IN "DIVISION 1 - GENERAL REQUIREMENTS" OF THE SPECIFICATIONS. THESE NOTES
DESIGN CRITERIA AND REFERENCES
CLARIFY.
THESE DRAWINGS SHALL NOT BE SCALED FOR DIMENSIONS. IF THERE ARE DIMENSIONS DISCREPANCIES OR CONCERNS, CONTACT THE FAA COR TO 15.
THE COST OF ANY CHANGES REQUIRED BY THE CLIENT TO SUITABLY MODIFY SUCH WORK SHALL BE SOLELY THE RESPONSIBILITY OF THE CONTRACTOR.
PRIOR TO THE BEGGINING OF THE AFFECTED WORK. WORK THAT PROCEEDS IN VIOLATION OF THIS PRINCIPLE IS AT THE CONTRACTOR'S OWN RISK, AND
THEREIN, SHALL BE REPORTED TO THE FAA CONTRACTING OFFICERS REPRESENTATIVE (COR) IMMEDIATELY, AND SUITABLE RESOLUTION ESTABLISHED
ANY DISCREPANCIES BETWEEN THE EXISTING CONDITIONS AND THE CONTRACT DOCUMENTS , OR ANY AMBIGUITIES OR INCONSISTENCIES CONTAIN 14.
IMMEDIATELY.
IF AN UNSAFE CONDITION OR LIFE THREATENING HAZARD IS NOTED AT THE SITE, NOTIFY THE FAA CONTRACTING OFFICERS REPRESENTATIVE 13.
MANUFACTURED ITEMS SHALL BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS.12.
ALL EXTERIOR DIMENSIONS ARE FROM THE EXTERIOR FACE OF WALL.11.
ALL INTERIOR DIMENSIONS ARE FROM THE FACE OF STUD OF MASONRY STRUCTURE, UNLESS OTHERWISE NOTED.10.
REINSTALL ALL SMOKE/FIRE DETECTORS AS REQUIRED.9.
DO NOT PAINT OVER ANY FIRE DOOR LABEL.8.
REPRESENTATIVE SHALL APPROVE THE SYSTEM TO BE UTILIZED FOR VENTILATION PRIOR TO USE.
PAINTING, CURING OF FRP RESINS AND OTHER CONSTRUCTION ACTIVITIES THAT HAVE THE POTENTIAL FOR STRONG ODORS. THE CONTRACTING OFFICERS
CONTRACTOR SHALL USE VERY LOW VOC PAINTS AND COATINGS AND PROVIDE ADEQUATE MEASURES FOR VENTILATION TO MINIMIZE ODORS DURING 7.
RELOCATED BY THE CONTRACTOR. COORDINATE WITH CONTRACTING OFFICERS REPRESENTATIVE.
IF NECESSARY ALL ELECTRONIC EQUIPMENT CIRCUITS SHALL BE RELOCATED BY THE FAA. ALL OTHER BUILDING SYSTEMS CIRCUITS SHALL BE 6.
LOCKOUT AND TAG PROCEDURES MUST BE FOLLOWED AT ALL TIMES.5.
DISRUPTION TO THE NORMAL OPERATIONS OF THE FACILITY. NORMAL HOURS OF OPERATION ARE STATED IN DIVISION 1 OF THE SPECIFICATIONS.
FACILITY DURING NORMAL OPERATING HOURS. ALL WORK NEEDS TO BE COORDINATED WITH FAA CONTRACTING OFFICERS REPRESENTATIVE TO AVOID
THE CONSTRUCTION OF THIS PROJECT MUST NOT INTERFERE WITH OPERATION OF THE AIR TRAFFIC CONTROL FUNCTION OR ACCESS AND EGRESS TO THE 4.
AREA DURING ALL GENERAL CONSTRUCTION SEQUENCES.
CONSTRUCTION NOISE, DUST AND DEBRIS MUST NOT INTERFERE WITH OPERATION OF ATCT FACILITY. MAINTAIN HEPA FILTRATION OF CONSTRUCTION 3.
SIGNIFICANT AMOUNTS OF WORK MUST BE COMPLETED AFTER NORMAL OPERATING HOURS. 2.
NOTICE TO PROCEED IS ISSUED. SCHEDULE SHALL OUTLINE ALL PHASES OF THE WORK AND THEIR IMPACT ON THE OPERATION OF THE FACILITY.
PLAN AND PROVIDE A COMPLETE AND COMPREHENSIVE SCHEDULE TO THE CONTRACTING OFFICERS REPRESENTATIVE FOR REVIEW AND APPROVAL BEFORE A
FAA WILL COORDINATE PHASING PLAN WITH FACILITY TO MINIMIZE THE DISRUPTION OF OPERATIONS. THE CONTRACTOR SHALL USE THIS PHASING 1.
DEMOLITION NOTES
AFTER NEW CONSTRUCTION IS COMPLETED.
IF A PORTION OF AN EXISTING WALL IS DEMOLISHED OR PATCHED, THE ENTIRE WALL OR CEILING SHALL BE PAINTED 3.
STRUCTURAL INTEGRITY SHALL BE MAINTAINED FOR ALL BUILDING ELEMENTS DURING AND AFTER DEMOLITION.2.
EXISTING APPEARANCE, UNLESS NOTED OTHERWISE.
BY THE CONSTRUCTION TO MAINTAIN THEIR FIXTURES OR BUILDING ASSEMBLIES. REPAIR ALL AREAS AFFECTED
FACILITY TO BE PROTECTED DURING CONSTRUCTION AND FROM DAMAGE TO ANY EXISTING OR ADJACENT FINISHES, MATERIALS, 1.
APPLICABLE FAA ORDERS AND STANDARDS.-
NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) 780, STANDARD FOR THE INSTALLATION OF LIGHT PROTECTION SYSTEMS, 2015.-
NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) 110, STANDARD FOR EMERGENCY AND STANDBY POWER SYSTEMS, 2016-
NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) 101, LIFE SAFETY CODE, 2015-
NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) 92, STANDARD FOR SMOKE CONTROL SYSTEMS, 2015.-
NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) 90A, STANDARD FOR THE INSTALLATION OF AIR-CONDITIONING AND VENTILATION SYSTEMS, 2015.-
NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) 75, STANDARD FOR THE PROTECTION OF INFORMATION TECHNOLOGY EQUIPMENT, 2013.-
NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) 72, NATIONAL FIE ALARM AND SIGNALING CODE, 2016.-
NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) 70, NATIONAL ELECTRICAL CODE, 2017.-
NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) 20, STANDARD FOR THE INSTALLATION STATIONARY PUMPS FOR FIRE PROTECTION, 2016.-
NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) 13, STANDARD FOR THE INSTALLATION OF SPRINKLER SYSTEMS, 2016.-
NATIONAL ELECTRICAL CODE (NEC), 2017.-
INTERNATIONAL PLUMBING CODE (IPC), 2015.-
INTERNATIONAL MECHANICAL CODE (IMC), 2015.-
INTERNATIONAL FIRE CODE (IFC), 2015.-
INTERNATIONAL BUILDING CODE (IBC), 2015.-
FEDERAL AVIATION ADMINISTRATION
DEPARTMENT OF TRANSPORTATION
DESCRIPTION
DATE
APPROVED
PAGE OF
WW JOB NUMBER: 219075.00 FLL-D-ATCT-
REVIEWED BY
SUBMITTED BY APPROVED BY
ISSUED BY DATE
DRAWING NO REV
DESIGNED
DRAWN
CHECKED
REV JCN
DATE
REDLINE
APVD
JCN
1508912
FL
wileywilson.com
678.320.1888
Atlanta, Georgia 30328-6055
Bldg. C, Ste 515
5901 Peachtree Dunwoody Rd.
Wiley|Wilson
SUBMITTER'S TITLE - CIVIL ENGINEER APPROVER'S TITLE - MANAGER
SCALES SHOWN FOR 22" X 34" SHEET. ADJUST SCALES FOR OTHER SIZES.
CENTER
ENGINEERING
ATLANTA TERMINAL
FT LAUDERDALE (INTERNATIONAL)
MAJOR IMPROVEMENTS
FORT LAUDERDALE AIRPORT TRAFFIC CONTROL TOWER
JAN 31, 2020
H001
THE PROJECT
AFFECTED BY
(SEE SPECIFICATIONS FOR ACM REPORT)
SUSPECTED ASBESTOS MATERIAL LOCATION SUMMARY
(ACM)
ASBESTOS MATERIAL
HAZARDOUS MATERIALS
GENERAL
HAZMAT NOTES
REQUIREMENTS.
MEDIA AND HANDLED AND DISPOSED OF CONSISTENT WITH ALL APPLICABLE LAWS AND
SUBSTANCES, OR MATERIALS, ARE MANAGED TO AVOID CONTAMINATION OF ENVIRONMENTAL
THOSE THAT CONSIST OF ASBESTOS, LEAD, OR OTHER HAZARDOUS CONSTITUENTS, WASTES,
4. THE CONTRACTOR SHALL ENSURE THAT ALL DEMOLITION GENERATED SOLID WASTES, INCLUDING
PAINT. REFER TO FAA STANDARD SPECIFICATIONS.
3. PAINTED AREAS SUCH AS THE STAIR HANDRAILS ARE ASSUMED TO CONTAIN LEAD-BASED
TO APPROPRIATE SECTIONS OF FAA STANDARD SPECIFICATIONS.
2. IT IS THE INTENT OF THIS DRAWING FOR ALL EXISTING ACM TO BE REMOVED. REFER
IS LISTED.
THE COMPLETE REPORT IS ON FILE WITH THE FAA. PROVIDE TEST WHERE ASSUMED ACM
A SUMMARY OF THIS REPORT IS INCLUDED AS AN APPENDIX TO THE SPECIFICATIONS.
SHOWN IN THE REPORT PREPARED BY RESEARCH MANAGEMENT CONSULTANTS, INC.
IS A SUMMARY OF ASBESTOS CONTAINING MATERIAL (ACM) AND IT'S LOCATION AS
1. BUILDING CONTAINS HAZARDOUS MATERIAL (HAZMAT). THE TABLE ON THIS DRAWING ROOM NAME
STAIRS
10TH FLOOR (JUNCTION LEVEL),
CORRIDOR
10TH FLOOR (JUNCTION LEVEL),
EQUIPM ROOM
10TH FLOOR (JUNCTION LEVEL),
ATCT
TELCO
EQUIPMENT ROOM
TELCO
CONFERENCE ROOM
AF STORAGE
AF STORAGE, EAST WALL
BASE BUILDING
6" BEIGE BASE BOARD TAN MASTIC
12"X12" PEACH VINYL FLOOR TILE TAN MASTIC
YELLOW MASTIC
TAN MASTIC
12"X12" WHITE VINYL FLOOR TILE
4" BROWN VINYL BASEBOARD
WITH SPOTS AND BLACK MASTIC
12"X 12"WHITE VINYL FLOOR TILE
BLACK MASTIC
OFF WHITE FLOOR TILE
BLACK MASTIC
WITH SPOTS AND BLACK MASTIC
12"X 12"WHITE VINYL FLOOR TILE
2" BLACK VINYL BASE BOARD YELLOW MASTIC
WITH JOINT COMPOUND
INTERIOR PERIMETER DRYWALL
WHITE JOINT COMPOUND
YELLOW MASTICTILE GREY SPOTS
12"X 12" WHITE VINYL FLOOR
STRIKES AND MASTIC
BLACK VINYL FLOOR TILE WITH
YELLOW MASTIC
TEM - SAMPLE NOT ANALYZED
TEM - SAMPLE NOT ANALYZED
ASSUME ACM
TEM - SAMPLE NOT ANALYZED
TEM - SAMPLE NOT ANALYZED
TEM - SAMPLE NOT ANALYZED
TEM - SAMPLE NOT ANALYZED
ASSUME ACM
TEM - SAMPLE NOT ANALYZED
TEM - SAMPLE NOT ANALYZED
YES
YES
YES
RESULTS
GMR
GMR
RAB
NO
NO
NO
NO
NO
NO
NO
NO
YES
YES
YES
FEDERAL AVIATION ADMINISTRATION
DEPARTMENT OF TRANSPORTATION
DESCRIPTION
DATE
APPROVED
PAGE OF
REVIEWED BY
SUBMITTED BY APPROVED BY
ISSUED BY DATE
DRAWING NO REV
DESIGNED
DRAWN
CHECKED
REV JCN
DATE
REDLINE
APVD
JCN
wileywilson.com
678.320.1888
Atlanta, Georgia 30328-6055
Bldg. C, Ste 515
5901 Peachtree Dunwoody Rd.
Wiley|Wilson
SUBMITTER'S TITLE - CIVIL ENGINEER APPROVER'S TITLE - MANAGER
SCALES SHOWN FOR 22" X 34" SHEET. ADJUST SCALES FOR OTHER SIZES.
FT LAUDERDALE (INTERNATIONAL) FL
FLL-D-TOWB-
1508912
CENTER
ENGINEERING
ATLANTA TERMINAL
WW JOB NUMBER: 219075.00
MAJOR IMPROVEMENTS
FORT LAUDERDALE AIRPORT TRAFFIC CONTROL TOWER
JAN 31, 2020
CRK
CRK
G000
(TRAC0)
TRACON BASE BUILDING
FEDERAL AVIATION ADMINISTRATION
DEPARTMENT OF TRANSPORTATION
DESCRIPTION
DATE
APPROVED
PAGE OF
WW JOB NUMBER: 219075.00 FLL-D-TRACO-
REVIEWED BY
SUBMITTED BY APPROVED BY
ISSUED BY DATE
DRAWING NO REV
DESIGNED
DRAWN
CHECKED
REV JCN
DATE
REDLINE
APVD
JCN
1508912
FL
wileywilson.com
678.320.1888
Atlanta, Georgia 30328-6055
Bldg. C, Ste 515
5901 Peachtree Dunwoody Rd.
Wiley|Wilson
SUBMITTER'S TITLE - CIVIL ENGINEER APPROVER'S TITLE - MANAGER
SCALES SHOWN FOR 22" X 34" SHEET. ADJUST SCALES FOR OTHER SIZES.
CENTER
ENGINEERING
ATLANTA TERMINAL
FT LAUDERDALE (INTERNATIONAL)
MAJOR IMPROVEMENTS
FORT LAUDERDALE AIRPORT TRAFFIC CONTROL TOWER
JAN 31, 2020
020' 20' 40'
1" = 20' - 0" D000
CRK
JJS
NOTES
SITE PLAN - DEMOLITION
PLUMBING
SCALE: 1" = 20'-0" D000
1 PLUMBING SITE PLAN - DEMOLITION
GENERAL NOTES
EX. 4" SAN
WORK WITH COTR.
THIS AREA MUST BE PERFORMED WHEN TOWER IS UNOCCUPIED. COORDINATE
THIS CONCRETE PATH IS MAIN EGRESS TO BUILDING. ANY WORK ON 2
FROM PLANS DATED 08/04/1987. SEE ATCT-D400 FOR CONTINUATION.
TO 8" LINE. APPROXIMATE LOCATION OF EXISTING 8" PIPE IS SHOWN
REPLACE EXISTING 4" SANITARY SEWER FOR ENTIRE LENGTH OF RUN1
WORK SHALL NOT COMMENCE UNTIL NEW PIPE HAS BEEN INSTALLED.
PIPE SHOWN ALSO SERVES EXISTING RESTROOM AT TOP OF ATCT. DEMOLITIONB.
TOWB-G011 FOR ABBREVIATIONS.
SEE TRACO-P000 FOR GENERAL NOTES AND SYMBOLS. SEE TOWB-G010 AND A.
OF 8" SAN
LOCATION
APPROXIMATE
JJS
FEDERAL AVIATION ADMINISTRATION
DEPARTMENT OF TRANSPORTATION
DESCRIPTION
DATE
APPROVED
PAGE OF
WW JOB NUMBER: 219075.00 FLL-D-TRACO-
REVIEWED BY
SUBMITTED BY APPROVED BY
ISSUED BY DATE
DRAWING NO REV
DESIGNED
DRAWN
CHECKED
REV JCN
DATE
REDLINE
APVD
JCN
1508912
FL
wileywilson.com
678.320.1888
Atlanta, Georgia 30328-6055
Bldg. C, Ste 515
5901 Peachtree Dunwoody Rd.
Wiley|Wilson
SUBMITTER'S TITLE - CIVIL ENGINEER APPROVER'S TITLE - MANAGER
SCALES SHOWN FOR 22" X 34" SHEET. ADJUST SCALES FOR OTHER SIZES.
N
CENTER
ENGINEERING
ATLANTA TERMINAL
FT LAUDERDALE (INTERNATIONAL)
MAJOR IMPROVEMENTS
FORT LAUDERDALE AIRPORT TRAFFIC CONTROL TOWER
JAN 31, 2020
BASE BUILDING
ATCT
ROOM
GENERATOR
ENGINE
ROOM
BREAK
D300
SCALE: 3/16" = 1' - 0"D300
1 BASE BUILDING HVAC FLOOR PLAN - DEMOLITION
10x6
OA DUCT
24X12
CFM
CFM
6"
26x20
26x22 6x6
CFM
10x6
14x8
CFM
CFM
CFM
CFM
3/16" = 1'-0"
04' 4' 8' 12'
8x6
V A
V
O
VAV-2
V
2 5"Ø
Ø
8"Ø
6x6
CFM
10"Ø x
TO VAV-3
VAV-3
CFM
10x10
CFM
8x8 6"Ø
CFM
CFM
V x x
18x8
8x6 x
VAV-7
10"Ø
Ø x
26x8VAV-8
FCU-1 & 2
12"Ø
12x12 x
16x8
16x8 x x
(TYP OF 4)
650 CFM
16x8
16x8
24x16
FCU-2 FCU-1
C
U
150 CFM
8x6
8x8
12x6
TO VAV-5AHU-1
x
VAV-5
5"Ø
VAV-6 10x8
VAV-6
TO
x
(TYP 0F 4)
100 CFM
CFM
Ø6x6
Ø
6x6
8x6 x
CFM
Ø 6x6
80 CFM
TO VAV-4
6x8 x
10x10
VAV-4
5"Ø x
14x8 x
8x6 6"Ø
M M
BASE BUILDING FLOOR PLAN - DEMOLITION
MECHANICAL
T
T
T
T
T
T
T
T
M M
M T
M
M
S D
CO2
P
Ø
VAV-1
12"Ø
OA DUCT
16X12
RA DUCT
14x40
HP-2
HP-1
CU-1
NOTES
GENERAL NOTES
CFM
CFM
CRKCRK
JJS
JJS
4 4
D301
CFM
CFM
116 117/
107 106
MECHANICAL ROOM
COORDINATOR
NAV/COMM
C O
R R I
D O
R
CONFERENCE ROOM
AF STORAGE
VEST.
AF SSC
SECRETARY
AT MANAGER
AT DEPUTY
VESTIBULE
EPDS
CORRIDORCORRIDOR
CORRIDOR
ADMIN. STOR.
AF/AT
ASST. AT
LOCKER ROOM
BREAK ROOM
ROOM
MEN'S
CORRIDOR
ROOM
WOMENS
JANITOR
CORRIDOR
LINK
TELCO
SCREENED PORCH
TRAINING/STOR.
STORAGE
CFM
CFM
ROOM
EQUIPMENT
CFM
ROOM
PLAYBACK
COORDINATOR
RADAR
6"
OWNER SHALL HAVE FIRST RIGHT TO ALL EQUIPMENT THAT IS REMOVED.G.
CONTRACTORS.
RATING AND SHALL BE COORDINATED WITH THE FIRE ALARM AND ELECTRICAL
THIS WORK, THE REMOVED DAMPER SHALL BE REPLACED WITH THE SAME TYPE,
WHERE FIRE OR FIRE/SMOKE DAMPERS ARE REMOVED IN CONJUNCTION WITH F.
NOTES.
SEE DRAWING TRACO-M000 FOR HVAC LEGEND, GENERAL NOTES AND SPECIAL E.
MINIMIZE DOWNTIME OF THE HVAC SYSTEM.
CONTROL INSTALLATION PRIOR TO PERFORMING ANY WORK AND SHALL
CONTRACTOR SHALL REVIEW THE EXISTING CONTROL DRAWINGS AND ACTUAL D.
THERMOSTATS AND ALL ASSOCIATED CONTROL COMPONENTS.
INCLUDING OPERATOR WORKSTATION, CONTROL PANELS, CONTROL WIRING,
CONTRACTOR SHALL COMPLETELY REMOVE THE EXISTING HVAC CONTROL SYSTEM C.
EXISTING WORK SHOWN LIGHT SOLID LINE WITHOUT HATCHING SHALL REMAIN.B.
NEW AIR DEVICES TO AIR FLOW INDICATED.
AFTER CONSTRUCTION. THE SYSTEM SHALL BE REBALANCED ALL EXISTING AND
SUBMITTED TO THE FAA CONTRACTING OFFICER REPRESENTATIVE FOR REVIEW,
COMPLETION OF THE MECHANICAL WORK. THE ACTUAL AIR FLOW SHALL BE
RESULTS SHALL BE RETAINED AND USED TO RESTORE THE SYSTEM AT THE
BUILDING, PRIOR TO CONSTRUCTION START OR ANY HVAC DEMOLITION WORK,
AND RECORD THE ACTUAL AIR FLOW ON EXISTING AIR OUTLETS IN BASE
DRAWINGS. THE APPROVED TAB CONTRACTOR SHALL PERFORM AIR FLOW TEST
AIR FLOW SHOWN ON EXISTING SUPPLY AIR OUTLETS ARE FROM AS-BUILT A.
10 FSD9 M
UP TO EXISTING EF-2, EF-2 TO BE REMOVED.10
REMOVE EXISTING FIRE-SMOKE DAMPER (TYP 2).9
REMOVE EXISTING DDC CONTROL PANEL.8
REMOVE TAP AND MVD. PATCH AND SEAL DUCTWORK AIRTIGHT.7
EXISTING MAKE-UP AIR DUCT FOR TOILETS.6
REMOVE EXISTING THERMOSTAT.5
REMOVE EXISTING CONTROL DAMPERS AND ACTUATORS.4
AIR HANDLING UNIT AHU-1 REPLACED IN INITIAL PHASE OF RENOVATION.3
REMOVE VAV BOXES (VAV-1 THRU VAV-8) AND FD WHERE APLICABLE.2
PHASE OF RENOVATION.
CONDENSING UNIT (CU-1) AND ASSOCIATED LINESET REPLACED IN INTIAL 1
FSD
FEDERAL AVIATION ADMINISTRATION
DEPARTMENT OF TRANSPORTATION
DESCRIPTION
DATE
APPROVED
PAGE OF
WW JOB NUMBER: 219075.00 FLL-D-TRACO-
REVIEWED BY
SUBMITTED BY APPROVED BY
ISSUED BY DATE
DRAWING NO REV
DESIGNED
DRAWN
CHECKED
REV JCN
DATE
REDLINE
APVD
JCN
1508912
FL
wileywilson.com
678.320.1888
Atlanta, Georgia 30328-6055
Bldg. C, Ste 515
5901 Peachtree Dunwoody Rd.
Wiley|Wilson
SUBMITTER'S TITLE - CIVIL ENGINEER APPROVER'S TITLE - MANAGER
SCALES SHOWN FOR 22" X 34" SHEET. ADJUST SCALES FOR OTHER SIZES.
N
CENTER
ENGINEERING
ATLANTA TERMINAL
FT LAUDERDALE (INTERNATIONAL)
MAJOR IMPROVEMENTS
FORT LAUDERDALE AIRPORT TRAFFIC CONTROL TOWER
JAN 31, 2020
CORRIDOR
SE
E
TOWER
DWG'
S.
MAT
CHL
IN
E
D301
NOTES
SA DUCT
14X18 LINED
SEGMENT
SUPPLY FAN
AHU-1
SEGMENT
VERTICAL COIL
MIXING BOX SEGMENT
COMBINATION FILTER AND
CONNECTION (TYP.)
FLEXIBLE DUCT
FINISHED FLOOR
OA DUCT
16X12 LINED
RA DUCT
40X14 LINED
A.F.F.
CEILING 8'-0"
SA DUCT
18X14 LINED
TRANSITION
SD
SD
FD
ROOF
M
MECHANICAL ROOM BASE BUILDING PLAN - DEMOLITION
MECHANICAL
SCALE: 3/8" = 1'-0"D301
1 MECHANICAL ROOM BASE BUILDING PLAN - DEMOLITION
MOTORIZED DAMPER
CRK
JJS
JJS
3/8" = 1'-0"
02' 2' 4' 6'
REMOVE EXISTING SMOKE DETECTORS.3
EXISTING MOTORIZED DAMPER TO REMAIN.2
EXISTING AHU-1 REPLACED IN INITIAL PHASE OF RENOVATION.1
FEDERAL AVIATION ADMINISTRATION
DEPARTMENT OF TRANSPORTATION
DESCRIPTION
DATE
APPROVED
PAGE OF
WW JOB NUMBER: 219075.00 FLL-D-TRACO-
REVIEWED BY
SUBMITTED BY APPROVED BY
ISSUED BY DATE
DRAWING NO REV
DESIGNED
DRAWN
CHECKED
REV JCN
DATE
REDLINE
APVD
JCN
1508912
FL
wileywilson.com
678.320.1888
Atlanta, Georgia 30328-6055
Bldg. C, Ste 515
5901 Peachtree Dunwoody Rd.
Wiley|Wilson
SUBMITTER'S TITLE - CIVIL ENGINEER APPROVER'S TITLE - MANAGER
SCALES SHOWN FOR 22" X 34" SHEET. ADJUST SCALES FOR OTHER SIZES.
CENTER
ENGINEERING
ATLANTA TERMINAL
FT LAUDERDALE (INTERNATIONAL)
MAJOR IMPROVEMENTS
FORT LAUDERDALE AIRPORT TRAFFIC CONTROL TOWER
JAN 31, 2020
D400 3/16" = 1'-0"
04' 4' 8' 12'
JJS
CRK
JJS
BASE BUILDING FLOOR PLAN - DEMOLITION
PLUMBING
SCALE: 3/16" = 1' - 0"D400
1 BASE BUILDING FLOOR PLAN - DEMOLITION
D401
MECHANICAL ROOM
COORDINATOR
NAV/COMM
CORRIDOR
VEST.
AF STORAGE
CONFERENCE ROOM
EQUIPMENT ROOM
STORAGE
TELCO
SCREENED PORCH
LINK
JANITOR
CORRIDOR
RADAR COORDINATOR
AF SSC
SECRETARY
ADMIN OFFICE
QUIET ROOM
102ROOM
CBI/PLAYBACK
TRAINING/STOR.
AT MANAGER
AT DEPUTY
EPDS
CORRIDOR
CORRIDORCORRIDOR
VESTIBULE
LOCKER ROOM
ROOM
MEN'S
BREAK ROOM
CORRIDOR
ROOM
WOMENS
CO
CO
3" RD
3" UP TO
3" RD
CO
3" RD
S D
CO
3" RD
FOR CONTINUATION
SEE DWG. ATCT-D400
NOTES
GENERAL NOTES
1 1
REMOVED AND REPLACED FOR WORK.
TRACO-P100 FOR MORE INFORMATION. CEILING TILES WILL NEED TO BE
REMOVE EXISTING ROOF DRAINS AND REPLACE WITH 4" ROOF DRAINS. SEE 1
4" SD (AC)
4" SD (AC)
6" SD (BF)
3" SD (AC)
BY START OF ATCT OPERATIONS.
WORK NEEDS TO BE COMPLETED AND BUILDING PUT BACK TO WORKING ORDER
ALL WORK IN THIS AREA SHALL BE COMPLETED AFTER HOURS. ALL PHASED C.
DEVIATE SIGNIFICANTLY FROM CONTRACT DOCUMENTS.
CONTRACTOR SHALL NOTIFY ENGINEER IN WRITING IF SITE CONDITIONS B.
TOWB-G010 AND TOWB-G011 FOR ABBREVIATIONS.
SEE DRAWING TRACO-P000 FOR PLUMBING GENERAL NOTES AND SYMBOLS. SEE A.
FEDERAL AVIATION ADMINISTRATION
DEPARTMENT OF TRANSPORTATION
DESCRIPTION
DATE
APPROVED
PAGE OF
WW JOB NUMBER: 219075.00 FLL-D-TRACO-
REVIEWED BY
SUBMITTED BY APPROVED BY
ISSUED BY DATE
DRAWING NO REV
DESIGNED
DRAWN
CHECKED
REV JCN
DATE
REDLINE
APVD
JCN
1508912
FL
wileywilson.com
678.320.1888
Atlanta, Georgia 30328-6055
Bldg. C, Ste 515
5901 Peachtree Dunwoody Rd.
Wiley|Wilson
SUBMITTER'S TITLE - CIVIL ENGINEER APPROVER'S TITLE - MANAGER
SCALES SHOWN FOR 22" X 34" SHEET. ADJUST SCALES FOR OTHER SIZES.
N
CENTER
ENGINEERING
ATLANTA TERMINAL
FT LAUDERDALE (INTERNATIONAL)
MAJOR IMPROVEMENTS
FORT LAUDERDALE AIRPORT TRAFFIC CONTROL TOWER
JAN 31, 2020
A B C
CORRIDOR
SE
E
TOWER
DWG'
S.
MAT
CHL
IN
E
ROOM
MEN'S
NOTES
D401 3/8" = 1'-0"
02' 2' 4' 6'
ROOM
MEN'S
ENLARGED RESTROOM DEMOLITION PLAN
PLUMBING
FD
FD
2" VENT
EXISTING
4" VTR
CO
CO
GENERAL NOTES
SCALE: 3/8" = 1' - 0"D401
1 SANITARY DEMOLITION PLAN
ENLARGED RESTROOM
SCALE: 3/8" = 1' - 0"D401
2 DOMESTIC DEMOLITION PLAN
ENLARGED RESTROOM
1" HW
2" CW
H
3/4" CW
1 1/4" CW
ROOM
WOMENS
ROOM
WOMENS
CORRIDOR
CORRIDOR
EX. EWC-1
EX. UR-1
4" S
EXISTING
4 4
EX. L-12
2 EX. L-1
4 4
EX. L-1
EX. EWC-1
EWC-1
EX.
EX. L-1
L-1
EX.
EX. WC-1 EX. WC-1
EX. EWC-1
EX. WC-1 EX. WC-1
EX. WC-1 EX. WC-1
EX. L-1
EX. WC-1 EX.WC-1
JJS
CRK
TOWB-G011 FOR ABBREVIATIONS.
SEE TRACO-P000 FOR GENERAL NOTES AND SYMBOLS. SEE TOWB-G010 AND B.
EXISTING WORK SHOWN LIGHT SOLID LINE WITHOUT HATCHING SHALL REMAIN.A.
EX. UR-1
EX. UR-1A
EX. UR-1A
REMOVE BACK-TO-BACK WATER CLOSET CARRIER.6
FINISH IN THIS AREA TO BE DEMOLISHED.5
ASSOCIATED ACCESSORIES.
REMOVE EXISTING WATER CLOSET, FLUSH VALVE, SUPPORTS AND ALL 4
ASSOCIATED ACCESSORIES.
REMOVE EXISTING LAVATORY URINAL FLUSH VALVES, SUPPORTS, AND ALL 3
ACCESSORIES.
REMOVE EXISTING LAVATORY SUPPLY LINES, AND ALL ASSOCIATED 2
FLOOR DRAIN IN IT'S ENTIRETY WITH THE EXCEPTION OF THE P-TRAP.
REMOVE EXISTING FLOOR DRAIN AND ALL ASSOCIATED ACCESSORIES. REPLACE 1
6 6
JJS
FEDERAL AVIATION ADMINISTRATION
DEPARTMENT OF TRANSPORTATION
DESCRIPTION
DATE
APPROVED
PAGE OF
WW JOB NUMBER: 219075.00 FLL-D-TRACO-
REVIEWED BY
SUBMITTED BY APPROVED BY
ISSUED BY DATE
DRAWING NO REV
DESIGNED
DRAWN
CHECKED
REV JCN
DATE
REDLINE
APVD
JCN
1508912
FL
wileywilson.com
678.320.1888
Atlanta, Georgia 30328-6055
Bldg. C, Ste 515
5901 Peachtree Dunwoody Rd.
Wiley|Wilson
SUBMITTER'S TITLE - CIVIL ENGINEER APPROVER'S TITLE - MANAGER
SCALES SHOWN FOR 22" X 34" SHEET. ADJUST SCALES FOR OTHER SIZES.
N
CENTER
ENGINEERING
ATLANTA TERMINAL
FT LAUDERDALE (INTERNATIONAL)
MAJOR IMPROVEMENTS
FORT LAUDERDALE AIRPORT TRAFFIC CONTROL TOWER
JAN 31, 2020
D500 3/16" = 1'-0"
04' 4' 8' 12'
BASE BUILDING FLOOR PLAN - DEMOLITION
ELECTRICAL
CU-1
GENERAL NOTES
CRKCRK
JMC
SCALE: 3/16" = 1' - 0"D500
1 BASE BUILDING FLOOR PLAN - DEMOLITION
F A
C P
HP-1
HP-2
KEY NOTES
VAV-1
VAV-2
VAV-7
VAV-3
2 VAV-4
VAV-8 2
VAV-6 2
VAV-52
2 2
MAK
AHU-1
PANEL #9
EXISTING
FCU-2 FCU-1
MECHANICAL ROOM
AF STORAGE
VEST.
C O
R R I
D O
R
CONFERENCE ROOM
116 117/
COORDINATOR
RADAR
COORDINATOR
NAV/COMM
ROOM
EQUIPMENT
STORAGE
TELCO
AF SSC
TRAINING/STOR.
ROOM
PLAYBACK
JANITOR
CORRIDOR
CORRIDOR
CORRIDOR
ADMIN. STOR.
AF/AT
SECRETARY
AT MANAGER
AT DEPUTY
EPDS
VESTIBULE
LOCKER ROOM
ROOM
MEN'S
BREAK ROOM
ROOM
WOMENS
CORRIDOR
ASST. AT
EXISTING NPA
ELPA
EXISTING
SECT 1,2
EXISTING NLPA
SCREENED PORCH
NPA-25,27
NLPA-42,44
NPA-6,8
NPA-10,12
NPA-13,15
NLPA-45,47
NPA-26,28,30
SHALL FIELD VERIFY ALL EXISTING CIRCUITS PRIOR TO DEMOLITION.
ALL CIRCUIT NUMBERS ARE BASED ON AS-BUILT DRAWINGS. CONTRACTOR D.
ROOF. REMOVE ALL ELECTRICAL CONDUCTORS AND CONDUIT BACK TO PANEL.
SEE DRAWING TRACO-D501 FOR ELECTRICAL DEMOLITION REQUIRED ON THE C.
GENERAL NOTES AND SPECIAL NOTES.
SEE DRAWING TRACO-E000 AND TRACO-E001 FOR ELECTRICAL LEGEND, B.
EXISTING WORK SHOWN LIGHT SOLID LINE WITHOUT HATCHING SHALL REMAIN.A.
NPA-19,
PANEL #10
EXISTING
S
S
FSD M
MECHANICAL. REMOVE CIRCUIT BACK TO SOURCE.
EXISTING DDC CONTROL PANEL TO BE REPLACED. COORDINATE WITH 5
SHALL REMAIN FOR CONNECTION OF NEW DEVICES.
ELECTRICAL DEVICES WITHIN SPACE. CIRCUITS SERVED BY PANEL NLPA
RESTROOM TO BE RENOVATED. REMOVE ALL EXISTING LIGHT FIXTURES AND 4
SHALL BE CORRECTED BY THE CONTRACTOR AT NO ADDITIONAL COST.
CONDITIONS. ANY DAMAGE WHILE IN STORAGE OR DURING REINSTALLATION
CONTRACTOR SHALL DOCUMENT EXISTING CONDITIONS AND REINSTALL IN SAME
REMOVE AND SALVAGE EXISTING CEILING FANS AND LIGHT FIXTURES. 3
REMAIN FOR REUSE.
SWITCH AND REMOVE CONDUCTORS BACK TO PANEL. CONDUIT PATHWAY TO
EXISTING MECHANICAL EQUIPMENT TO BE REPLACED. REMOVE DISCONNECT 2
WITH MECHANICAL.
SERVED BY PANEL #9 TO BE REPLACED, WIRING TO REMAIN. COORDINATE
DISCONNECT CIRCUIT WIRING TO FIRE SMOKE DAMPERS 1 & 2. DAMPER 1
FEDERAL AVIATION ADMINISTRATION
DEPARTMENT OF TRANSPORTATION
DESCRIPTION
DATE
APPROVED
PAGE OF
WW JOB NUMBER: 219075.00 FLL-D-TRACO-
REVIEWED BY
SUBMITTED BY APPROVED BY
ISSUED BY DATE
DRAWING NO REV
DESIGNED
DRAWN
CHECKED
REV JCN
DATE
REDLINE
APVD
JCN
1508912
FL
wileywilson.com
678.320.1888
Atlanta, Georgia 30328-6055
Bldg. C, Ste 515
5901 Peachtree Dunwoody Rd.
Wiley|Wilson
SUBMITTER'S TITLE - CIVIL ENGINEER APPROVER'S TITLE - MANAGER
SCALES SHOWN FOR 22" X 34" SHEET. ADJUST SCALES FOR OTHER SIZES.
N
CENTER
ENGINEERING
ATLANTA TERMINAL
FT LAUDERDALE (INTERNATIONAL)
MAJOR IMPROVEMENTS
FORT LAUDERDALE AIRPORT TRAFFIC CONTROL TOWER
JAN 31, 2020
CORRIDOR
SE
E
TOWER
DWG'
S.
MAT
CHL
IN
E
SCALE: 3/16" = 1' - 0"D501
1 BASE BUILDING ROOF PLAN DEMOLITION
D501 3/16" = 1'-0"
04' 4' 8' 12'
BRP
CRK
MAK
BASE BUILDING ROOF PLAN DEMOLITION
ELECTRICAL
GENERAL NOTES
KEY NOTES
SHALL FIELD VERIFY ALL EXISTING CIRCUITS PRIOR TO DEMOLITION.
ALL CIRCUIT NUMBERS ARE BASED ON AS-BUILT DRAWINGS. CONTRACTOR D.
PANEL.
GROUND FLOOR. REMOVE ALL ELECTRICAL CONDUCTORS AND CONDUIT BACK TO
SEE DRAWING TRACO-D500 FOR ELECTRICAL DEMOLITION REQUIRED ON THE C.
GENERAL NOTES AND SPECIAL NOTES.
SEE DRAWING TRACO-E000 AND TRACO-E001 FOR ELECTRICAL LEGEND, B.
EXISTING WORK SHOWN LIGHT SOLID LINE WITHOUT HATCHING SHALL REMAIN.A.
REPLACED. REFER TO NEW WORK SHEET E-160 FROM MORE INFORMATION.
ENTIRE LIGHTNING PROTECTION SYSTEM CONDUCTORS AND HARDWARE TO BE 3
NEW FIXTURES
AND CONDUIT SERVED FROM PANEL NLPA SHALL REMAIN FOR CONNECTION OF
EXISTING LIGHT FIXTURES TO BE REPLACED. EXISTING LIGHTING CIRCUIT 2
EXHAUST FAN
CONDUIT SERVED FROM PANEL NPA SHALL REMAIN FOR CONNECTION OF NEW
EXISTING EXHAUST FAN EF-2 TO BE REPLACED. EXISTING CIRCUIT AND 1
FEDERAL AVIATION ADMINISTRATION
DEPARTMENT OF TRANSPORTATION
DESCRIPTION
DATE
APPROVED
PAGE OF
WW JOB NUMBER: 219075.00 FLL-D-TRACO-
REVIEWED BY
SUBMITTED BY APPROVED BY
ISSUED BY DATE
DRAWING NO REV
DESIGNED
DRAWN
CHECKED
REV JCN
DATE
REDLINE
APVD
JCN
1508912
FL
wileywilson.com
678.320.1888
Atlanta, Georgia 30328-6055
Bldg. C, Ste 515
5901 Peachtree Dunwoody Rd.
Wiley|Wilson
SUBMITTER'S TITLE - CIVIL ENGINEER APPROVER'S TITLE - MANAGER
SCALES SHOWN FOR 22" X 34" SHEET. ADJUST SCALES FOR OTHER SIZES.
N
CENTER
ENGINEERING
ATLANTA TERMINAL
FT LAUDERDALE (INTERNATIONAL)
MAJOR IMPROVEMENTS
FORT LAUDERDALE AIRPORT TRAFFIC CONTROL TOWER
JAN 31, 2020
BA C
TANK VTR
FUEL OIL
4" VTR
DOOR TYPES, SCHEDULE AND DETAILS
ARCHITECTURAL
A505
H E I
G H
T
T H I
C K
M A
T E
R I
A L
F I
N I
S H
T Y
P E
DOOR SCHEDULE HARDWARE SCHEDULE
W I
D T
H
SECURITY DOOR MATRIX
DOOR SCHEDULE
D O
L
O S
E R
W E
A T
H E
R I
P
L O
K
P E
E X
T E
D
A N
A M
E
I N
S T
A
O R
R E
M O
I
D
I N
S T
A
O R
G R
A D
E
B
R E
P A I
N G
T A
L
R E
A D
E R
E L
E C
T R
O N
R D
M A
G N
E T
N T
A C
T
E L
E C
T R
O N
R I
K E
E M
E R
G E
N
G N
N
G N
SCHEDULE