iVP XL E on Substructure Master view.pdf

PDF 70 KB Posted

Attached to
Y1DA--FY25: NRM (PROJ: 573-24-700) DB - Upgrade Electrical System - Kitchen
Solicitation number
36C24825R0011
Issued by

About this file

This technical drawing is a detailed connection diagram and dimensional specification for a RATIONAL AG iVario Pro 9L commercial cooking appliance mounted on a substructure (feet). The schematic provides precise measurements in millimeters and inches, with multiple view perspectives showing the device's spatial configuration and connection points.

The diagram includes a detailed connection overview with seven key connection types: 1) Cold water supply, 2) Drain, 3) Electrical connection, 4) Equipotential bonding, 5) Safety overflow (no connection), 6) Ethernet interface, and 7) Optional connections. An optional eighth connection point for hot water supply is also noted. The technical drawing is dated 15.03.2020, scaled at 1:1, and provides comprehensive technical specifications for installation and spatial requirements of the commercial kitchen equipment.

View the file

Other files

Show all 16

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

0 [

5 7 /8]

0 [

5/

8]

0 [

1/ 2]

8 [

7/

8]

[4

2 1 /2]

5 [

3/

8]

[4

0 1 /4]

5 [

7/

8]

0 [

1/ 2]

[6 9 1

/4] 1365 [53 3/4]

[3

3/ 4]

1115 [43 7/8] 200 [7 7/8]

120 [4 3/4] 120 [4 3/4] 1079 [42 1/2]

40 [1 5/8]6 [1/4]

1319 [51 7/8]

222 [8 3/4] 255 [10]

613 [24 1/8]

0 [

1/

4]

1 [

3/ 8]

6 [

1/

2]

[4 2 1

/2]

[6

9 1 /4]

0 [

5 7 /8]

8 [

1/

4]

330 [13]

1365 [53 3/4]

7 7

1 3 2 5

82°

1060 [41 3/4]

752 [29 5/8]

22 [7/8] 57 [2 1/4] 70 [2 3/4]

0 [

1/

4]

6 [

1/ 2]

1 [

3/

8]

[4 2 1

/2]

[6

9 1 /4]

0 [

5 7 /8]

8 [

1/

4]

80°

7 7

1 2 8 4 3

8 [

[2

0 [

5/ 8]

4 [

1/

4]

8 [

5 3 /8]

66 [2 5/8] 100 [3 7/8] 1199 [47 1/4] 1365 [53 3/4]

Ø65 [Ø2 1/2]

0 [0]

0 [ 0]

500 [19 5/8] 50 [2] min

Service Master View:

iVario Pro XL on substructure (feet)

Printed drawing is not automatically updated!

Zeichnungsausdruck unterliegt nicht dem Änderungsdienst!

La mise à jour n'est pas assurée sur les plans papier !

Information / Information / Information

Scale / Maßstab / Echelle

Date / Datum / Date

Dimensions / Abmessungen / Dimensions gim ©RATIONAL AG mm [inch]

Connection diagram / Anschlussplan / Plan de connexion

Creator / Ersteller / Créateur

15.03.2020

1 : 1

No. Description No. Beschreibung No. Description

1 Water supply cold

2 Drain

3 Electrical connection

4 Equipotential bonding

5 Safety overflow (no connection)

6 Ethernet interface

7 Options connections

Version 1

7Optionen Anschlüsse Connexions des options

Wasserzulauf kalt Alimentation eau froide

Wasserablauf Evacuation eaux usées Elektroanschluss Raccordement électrique Potentialausgleich Liaison équipotentielle Notüberlauf (kein Anschluss) Rupture de charge (pas de raccordement)

Ethernet-Schnittstelle Interface Ethernet

8 Option: Water supply hot 8 8Option: Wasserzulauf warm Option: alimentation eau chaude

Feuilles et vues
Standard Feet

File details come from the government source that posted it. Updated .