This is a Design Guidelines and Minimum Project Specifications document for the City of Ocala's Invitation to Negotiate (ITN# GRM/260331) regarding the development of affordable housing on Lot # 2220-005-003 in Ocala, Florida. The project requires construction of single-family residential units with a minimum of 900 square feet of livable area, at least 2 bedrooms and 2 bathrooms, designed to serve households up to 120% of Area Median Income as defined by the U.S. Department of Housing and Urban Development. The developer/contractor must comply with current Florida Building Code standards and provide all labor, materials, and equipment necessary for construction, including concrete driveways and sidewalks (minimum 750 square feet), single-car garages (minimum 12 feet wide by 20 feet deep), and a minimum of 6,500 square feet of sod landscaping around the home.
The specifications mandate specific architectural and functional components including concrete block construction on the first floor with durable exterior materials, architectural shingles rated for 130 mph winds with a 30-year warranty, energy-efficient split air source heat pump systems with a minimum 16 SEER2 rating, 200-amp electrical service, low-E argon-filled vinyl windows, and comprehensive plumbing fixtures from Delta Classic and American Standard manufacturers. Interior finishes must include solid wood cabinetry, waterproof vinyl plank flooring, ceramic tile in bathrooms, Sherwin Williams paint products, Energy Star-certified appliances, and ClosetMaid wire shelving. Exterior lighting must include LED motion security floodlights on each corner, and the developer is responsible for new connections to City of Ocala water and sewer systems with extensions from the city stub-out.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DESIGN GUIDELINES AND MINIMUM PROJECT SPECIFICATIONS
D-1
Developer/Contractor shall be responsible for providing all labor, materials, and equipment necessary to perform the services as described in the solicitation documents and in strict accordance with the current Florida Building Code. If a conflict exists, the more stringent regulation/specification shall govern. Developer/Contractor shall immediately notify the City Project Manager of any discovered conflicts.
These standards are the minimum project specifications, Developer/Contractor may exceed standards or provide comparable products/designs. This work includes, but is not limited to the following:
Architecture and Structural Components
• Building Materials - All homes should be constructed with different materials, including concrete block on the first floor, and be covered with durable exterior materials. No exposed concrete block is permitted. Alternative construction materials may be considered with regard to weather resistance, durability, aesthetics, and neighborhood compatibility.
• Concrete Driveway - Provide and install a new concrete driveway, sidewalk and driveway apron, location TBD. This area should be no less than 750 square feet.
• Garage- All homes should have at least a single car garage that is either attached or detached from the main house, measuring at least 12 feet wide by 20 feet deep with a 9-foot-wide door. This requirement may be waived in certain circumstances depending on lot size.
• Entry Doors (Exterior Rated) – Steel or fiberglass on rot-proof jams with rot-proof exterior trim. Stainless steel security hinges, with door stops. ADA-compliant door threshold, typical o Front Entry Door: Swinging – 3’-0” x 6’-8”, 6-panel (or similar design), Fiberglass or Steel, Peephole Viewer, Model DS238 OR Equivalent with Kwikset SmartKey lever-style ADA-compliant keyed-entry lockset. Matching deadbolt in brushed nickel or oil rubbed bronze finish.
o Storm Door: On front entry, install a full-light storm door with retractable window and screen. Use Larson Model # 14604032 OR substantially similar model with all necessary hardware. Matching front entry door hardware and color.
o Rear Entry Door: If drawings call for a sliding glass door, then follow the window specifications, or Swinging – 3’-0” x 6’-8”, 6-panel (or similar design), Fiberglass with ½-light with up/down/tilt blinds in the glass with Kwikset SmartKey lever-style ADA-compliant keyed-entry lockset. Matching deadbolt in brushed nickel or oil rubbed bronze finish.
• Interior Doors – Colonial style, 6-panel wood grain, hollow-core, pre-hung with KwikSet, ADA-compliant lever-style hardware. Privacy locks on bedrooms and bathrooms and passage on other rooms. In brushed nickel or oil rubbed bronze finish to match Entry Doors. 2-1/4” colonial casing, typical. All sizes per plans.
• Eve Drip – 2” aluminum drip-edge.
D-2
• Fascia / Soffit – Aluminum, woodgrain fascia and vented aluminum soffit, typical.
• Interior Studs – 2x4 Wood / #2 Spruce-Stud spacing 16” on center ( o.c.)
• Landscaping – Provide a minimum of 6500 square feet of sod, Argentine Bahia, around home. The remainder of the lot should be seeded and strawed. If the size is below 6500 SF, the area around the home should be sodded. Install a standard rural mailbox as per U.S.
Postal Service regulations. Install code approved house numbers in the most visible location. (Do not use stick on).
• Plate Height – Eight feet (8’) - Typical
• Roof Dry-In – Code-compliant water/moisture barrier – 100% of Roof
• Roof Pitch – 5/12-check elevations
• Roof Sheathing – ½” CDX or OSB
• Shingles – 30 yr. architectural, 130 m.p.h. rated (or better). Must provide written warranty, brand, model, and color to owner/representative. Install max amount of ridge vent.
• Size - All single-family units should be a minimum of 900 square feet of livable area and include at least 2 bedrooms and 2 bathrooms.
• Sidewalk/ADA Ramps – Provide a concrete ramp/walk from home to driveway, location
TBD. (Do not exceed 1:12 slope/2% cross slope)
• Vent Penetrations - 4”-6” bath vent boots (2 – sized per fan requirement). 8-10” Range
Hood Vent Boot (1), Ridge Vent is to be “Shingle Over” (“Cobra Vent”) style
• Windows/Sliding Glass Doors – Single Hung, Colonial Style, White Vinyl, Low-E, Argon
Filled, Energy Star Certified for Florida. Grids must be integrated in the glass. Screens must be provided.
Functional Components
• Ceiling Fan/LED Light Units – 44-inch to 52-inch in bedrooms, 52-inch in Living/Family room All fans to have reverse air-flow option, minimum 3000 CFM capable air movement All ceiling fan/lights are to have changeable-type LED bulbs/fixtures
• Electric Service – Overhead, 200 AMP main minimum
• Insulation – R-30 fiberglass batt in attic (min). R-13-15 fiberglass batt in walls or ¾” RMAX equal or better.
• Lighting - ALL light fixtures and ceiling fans to be Energy Star Certified (4000K +/- unless otherwise specified).
o Exterior – Provide LED motion security floodlights on each corner of the home.
Entry Doors – Standard bracket mount fixtures with LED changeable type bulbs Recessed Exterior Fixtures – To be “Wet Location” approved, LED with white trim o Interior – Kitchen/Dining Area – Recessed Can fixtures (if installed) to be LED Energy Star
D-3
Certified.
• Bathroom(s) – To have three (3) bulb tulip-style, fixtures with changeable LED bulbs.
• Light / Fan Switches/Receptacles – Toggle style typical (white)
• HVAC– Split air source heat pump. Minimum system requirements per current
Florida Building Code – mechanical and FBC. Energy Conservation Code requirements.
o Illuminated digital thermostat required. Matched/Compatible with HVAC System.
o 16 SEER2 minimum rating.
o Secondary “wet-switch” in condensate line required.
o AHRI Certificate and Energy Calculations and Manual D & J Required.
In each bathroom, provide and install “Delta Breez Green Builder,” Model 80HLED
(OR Equivalent) bathroom exhaust Fans with 4-inch semi-rigid aluminum duct to roof penetration. Fans to be run on dedicated GFCI Circuit with the LED Light on a separate switch.
In kitchen, provide and install ridged metal duct for microwave/range hood ventilation through the roof to exterior
• Meter Enclosure – Per NEC and OEU “Metering Enclosure and Equipment Standards”.
• Plumbing – ¼-turn Stops, typical (kitchen sink, refrigerator/ice maker, dishwasher, bathroom vanities, toilets, laundry supplies and hose bibs) o Kitchen: Double Basin Stainless Steel (33” X 22” X 8” Deep) Delta Classic Stainless 1-handle, High-arc faucet o Bathroom(s):
Delta Classic Tub and/or Shower Valve w/ Integrated Stops Delta Classic Chrome, Single lever shower trim Delta Classic Chrome, Single lever vanity faucet, typical Each tub/shower area to have recessed soap/shampoo niche shelves in each.
White, American Standard Cadet Series, 2-piece, ADA/Comfort/Right Height, “WaterSense Certified,” 1.28 GPF, Elongated Toilets w/ seat and lid– Typical Both Bathrooms
Install adequate wood backing for ADA grab bars, locations.
Install recessed, 3-shelf, mirrored medicine cabinets to the left or right of the vanity sink.
Install wall mirror, centered above each vanity sink.
Install towel bars in tub/shower area(s), and on the wall of the bathroom(s) Install toilet paper dispensers in most logical location to service the commode Install towel hook or ring next to the vanity sinks in most logical location(s)
• Smoke/CO Detectors – Smoke and smoke/CO detectors must be hard-wired and interconnected with non-serviceable 10-year battery back-ups.
• Water and Sewer Connections - Provide and install completely new connections to City of Ocala Water and Sewer Connections. The developer is responsible for extensions and restoration
D-4 needed to connect to the City stub-out (location to be determined by Developer).
• Finishes
• Appliances – All appliances (Frigidaire equal or better) to be Energy Star Certified (except range and microwave) o Appliances to be white, black or stainless steel Refrigerator/Freezer, 20 c.f. or larger w/water line/ice maker kit 30-inch Smooth-top, Freestanding Electric Range with Self Cleaning Oven w/power cord Dishwasher, top controls, provide all necessary power cords, drain and supply hoses.
30-inch, Over-the-range microwave oven/vent hood, with exterior ventilation.
Range, refrigerator, dishwasher and microwave MUST be same brand/matching model line and finish color).
• Bath Wall Tile-Ceramic to the ceiling with bullnose trim floor to ceiling.
• Cabinets – All Cabinets to be solid wood/plywood construction, w/ pulls, handles or knobs as appropriate.
o Kitchen Lower cabinet units per plan, door and drawers, standard height.
Upper cabinet units 30” +/- per plan Mica-type counter tops with integrated 4” backsplash per plans - typical o Bathroom(s) 36” counter height with solid surface top and 18” oval or integrated vanity sink
• Closet Shelving – ClosetMaid shelf type wire shelving typical in closets o All bedroom closets and above washer and dryer area, ClosetMaid shelf and rod type o ClosetMaid pantry/close mesh type wire shelving typical in pantry/laundry/linen
• Ceiling/walls – 1/2” Gypsum lightweight ceiling board w/ knock down texture, flat white paint
• Exterior Wall Construction – CMU/stucco
• Exterior Wall Finish –Paint
• Flooring – Waterproof vinyl plank flooring throughout. (Lighter colors suggested) o Bathroom Floors – Waterproof Vinyl Plank Flooring o Roll-in shower, to be porcelain or ceramic tile or PVC/fiberglass base.
• Front Entry Ceiling- Exterior drywall/paint
• Interior Trim – All interior trim styles to match. Colonial style finger-jointed, Casing 2-1/4”, Base 3-1/4” https://www.lowes.com/pl/Closetmaid--Wire-closet-shelves-Wire-closet-organizers-Closet-organization-Storage-organization/2350164646?refinement=4294965732 https://www.lowes.com/pl/Closetmaid--Wire-closet-shelves-Wire-closet-organizers-Closet-organization-Storage-organization/2350164646?refinement=4294965732 https://www.lowes.com/pl/Closetmaid--Wire-closet-shelves-Wire-closet-organizers-Closet-organization-Storage-organization/2350164646?refinement=4294965732
D-5
• Paint – All primer(s) to be Sherwin Williams Multi-Purpose Interior/Exterior Latex Primer, equal or better. All interior paint to be Sherwin Williams ProMar 200, low/no VOC equal or better. All exterior paint to be Sherwin Williams SuperPaint equal or better.
o Interior Ceilings to be flat white ceiling paint Wet/Damp areas to be semi-gloss finish All other areas to be satin finish All trim to be gloss finish o Exterior Ceilings (if paintable) to be exterior rated, flat white ceiling paint Walls to be satin All Trim to be gloss finish
• Paint General-Prep surfaces as per manufactures specs to include patching, filling and/or caulking. Apply 1 coat of an acrylic primer/sealer and paint with 2 coats of acrylic semi-gloss/satin/flat (3 coats in total).
| Architecture and Structural Components |
| Functional Components |
| o Interior – |
| o Bathroom(s): |
| Finishes |
| o Appliances to be white, black or stainless steel |
| Cabinets – All Cabinets to be solid wood/plywood construction, w/ pulls, handles or knobs as appropriate. |