About this file

This is a specification sheet for equipment stands designed to support SteamChef 3 and 6 counter-top steamers, prepared by Cleveland Range for the Savannah-Chatham County Public School System (SCCPSS) in Georgia as part of Bid 23-27 for Large Kitchen Equipment in the School Nutrition Program. The document details multiple equipment stand models manufactured by Cleveland Range, including the UNISTAND25, UNISTAND34, ES26304066E, ES26304433G, and ES26304466G, which are available in both electric and gas configurations. The stands are constructed entirely of stainless steel with welded construction, level-adjustable feet with flanged rear feet for floor bolting, preset mounting holes, and stainless steel bottom shelves. The specifications include detailed dimensional drawings showing front and right-side views for each model, with dimensions ranging from approximately 21.75 inches to 43.57 inches in width and varying depths and heights to accommodate different steamer configurations.

The document provides comprehensive specifications for five distinct stand models that can accommodate either one or two SteamChef units, with options for stacking multiple units when field installation is required. Standard features include all stainless steel construction with varying tubing sizes (1 1/4 inch square tubing for UNISTAND25 and UNISTAND34; 1 1/2 inch square tubing for larger models), adjustable feet with flanging for floor mounting, and integrated stainless steel bottom shelves. Optional features and accessories include a 100 psi steam jacket pressure option and control center placement on the left-hand console for applicable models. Each specification includes combinations with common drain and water connection manifolds to support multiple steamer units, with all installations requiring field assembly. Cleveland Range maintains design improvement rights and notes that compliance with regional, state, and local codes remains the responsibility of the owner and installer, with equipment built to U.L./NSF#4 and CSA (AGA, CGA) standards.

Text of this file

Project

Item

Quantity

FCSI Section 11400

Approved

Date

760 Beta Drive, Unit D

Mayfield Village, Ohio 44143

Tel 1.216.481.4900 Fax 1.216.481.3782 Email steam@clevelandrange.com www.clevelandrange.com

Steam chef™

3 & 6 Equipm ent Stands

SteamChef ™ 3 & 6

OPEN TYPE STAND,

ALL STAINLESS STEEL,

Models

• UNISTAND25 ELECTRIC UNITS - two 22CET3.1 or one 22CET6.1

GAS UNITS - one 22CGT3.1 or one 22CGT6.1

• UNISTAND34 ELECTRIC UNITS - two 22CET3.1 or one 22CET6.1 GAS UNITS - one 22CGT3.1 or one 22CGT6.1

• ES26304066E ELECTRIC UNITS - two 22CET6.1

• ES26304433G GAS UNITS - two 22CGT3.1

• ES26304466G GAS UNITS - two 22CGT6.1 or one 22CGT3.1 on top of one 22CGT6.1

Additional Stacking Kits required if purchased separately, contact factory.

Short Form Specifications Shall be CLEVELAND, ___________ open type Equipment Stands for mounting one or two SteamChef™ 3's or 6's. All Stainless Steel welded construction with; 1 1/4˝ square tubing for UNISTAND25 and UNISTAND34; 1 1/2" square tubing for ES263044___. Furnished with Level Adjustable Feet (rear feet are flanged for floor bolting). Preset mounting Holes for positioning unit into proper location

Standard Features

• Preset mounting holes for positioning unit into proper location

• All stainless steel welded construction with:

1 1/4˝ square tubing for UNISTAND25 and

UNISTAND34

1 1/2" square tubing ES26304066E and

ES26304466G

• Level adjustable feet (rear feet are flanged for floor bolting)

• Stainless steel bottom shelf

Options & Accessories

• 100 psi Steam Jacket pressure Option

• Control Center on left-hand Console *Not available for ES26304066E and ES26304466G

KE004046-100

Section 2, Page 21 5561A 10 / 2018

(2) 22CET3.1

Requires field installation. This combination includes:

• 2-each 22CET3.1 SteamChef ™ Counter Top Steamers

• 1-each ChefStackIt Direct Stacking Kit and install hardware

• 1-each UNISTAND25 Equipment Stacking Stand

• Common drain and water connection manifold

(2) 22CET6.1

Requires field installation. This combination includes:

• 2-each 22CET6.1 SteamChef ™ Counter Top Steamers

• ES26304066E Stacking Stand (PN 111467E)

• Common drain and water connection manifold

(2) 22CGT33.1

Requires field installation. This combination includes:

• 2-each 22CGT3.1 SteamChef ™ Counter Top Steamers

• 1-each ES26304433G Equipment Stacking Stand

• Common drain and water connection manifold

(2) 22CGT63.1

Requires field installation. This combination includes:

• 1-each 22CGT6.1 & 22CGT3.1 SteamChef ™ Counter Top Steamers

• ES26304466G Stacking Stand (PN 113130G)

• Common drain and water connection manifold

(2) 22CGT66.1

Requires field installation. This combination includes:

• 2-each 22CGT6.1 SteamChef ™ Counter Top Steamers

• ES26304466G Stacking Stand (PN 113130G)

• Common drain and water connection manifold

ES26304433E

& ES26304433G

UNISTAND 25

& UNISTAND34

760 Beta Drive, Unit D

Mayfield Village, Ohio 44143

Tel 1.216.481.4900 Fax 1.216.481.3782 Email steam@clevelandrange.com www.clevelandrange.com

St ea m ch ef

E qu ip m en t S ta nd s

(NOT TO SCALE)

FRONT

VIEW

RIGHT SIDE

VIEW

MODEL: UNISTAND25

FRONT

VIEW

RIGHT SIDE

VIEW

FRONT

VIEW

RIGHT SIDE

VIEW

FRONT

VIEW

RIGHT SIDE

VIEW

MODEL: ES26304066E

MODEL: ES26304433G

FRONT

VIEW

RIGHT SIDE

VIEW

MODEL: UNISTAND34

21.75" 552mm

25.50" 648mm

29.25" 743mm

39.29" 998mm

7.73" 196mm

43.57" 1107mm

17.73" 450mm

25.50" 648mm

29.25" 743mm

30.00" 762mm

25.26" 641mm

20.38" 518mm

28.60" 727mm

20.38" 518mm

28.60" 727mm

27.00" 686mm

30.00" 762mm

27.00" 686mm

30.00" 762mm

MODEL: ES26304466G

43.57" 1107mm

7.73" 196mm

25.50" 648mm

29.25" 743mm

27.00" 686mm

30.00" 762mm

33.19" 843mm

21.75" 552mm

30.00" 762mm

Section 2, Page 22 10 / 2018

NOTES:

Cleveland Range reserves right of design improvement or modification, as warranted.

Many regional, state and local codes exist and it is the responsibility of the owner and installer to comply with the codes.

Cleveland Range equipment is built to comply with applicable standards for manufacturers. Included among those approval agencies are U.L/NSF#4 and CSA (AGA, CGA).

Other files

File Type Posted
BID 23-27 SOLICITATION DOCUMEN —
ITEM 24 SPEC SHEET —
Bid 23-27 Addendum 1 —
BID NOTIFICATION LETTER —
REVISED BID SUBMITTAL FORM 12 —
ITEM 3 SPEC SHEET —
BID 23-27 SAMPLE CONTRACT —
ITEM 11 SPEC SHEET —
BID 23-27 ATTACHMENT E —
Award Information —

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

File details come from the government source that posted it. Updated .