This document is an architectural drawing (Sheet A-2) for the City of Warren's City Hall Library Meeting Room Improvements project, designated as ITB-W-1528. The plan depicts a partial floor plan for a 218 square foot meeting room renovation, which includes installing new moveable wall partitions, updating audio/visual equipment, and making necessary electrical and lighting modifications. The project scope involves reconfiguring the existing space with new AV components, relocating ceiling elements, and providing new power and support blocking for equipment.

The drawing outlines specific building code compliance details, including adherence to the 2021 Michigan Building Code, 2023 National Electric Code, and 2010 ADA Standards for Accessible Design. The work is classified as a Level 1 Alteration, with the use group designated as B (Business) and maintaining the existing construction type. The design ensures emergency egress remains accessible and specifies that the affected areas are not required to be fully accessible. The plan includes notes for contractors to verify exact equipment mounting locations, repair walls seamlessly, and coordinate with the owner's requirements for AV and electrical updates.

View the file

Other files

File Type Posted
ITB-W-1528 Corrected.pdf PDF
ITB-W-1528 A-1_Specs and Details-22x34.pdf PDF
ITB-W-1528.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

9'-5" CLEAR

3'-9" CLEAR

APPROVED

CHECKED

DRAWN

DESIGNED

DATE

HRC JOB NO.

DATE

SCALE

ADDITIONS AND/OR REVISIONS

SHEET

NO.

OF

555 HULET DRIVE

BLOOMFIELD HILLS, MICH.

P.O. BOX 824

48303 - 0824

PHONE: (248) 454-6300

WEB SITE: www.hrcengr.com

FAX (1st. Floor): (248) 454-6312 FAX (2nd. Floor): (248) 454-6359

CITY OF WARREN

CITY HALL LIBRARY

MEETING ROOM

IMPROVEMENTS

ITB - W - 1528

MCM

AMM

QR

AMM

AFFECTED

AREA

04-08-25 ISSUED FOR BID

PARTIAL FLOOR PLAN1

A-2 SCALE: 1/4" = 1'-0"

N MEETING ROOM

FLOOR PLAN

A-2

AS NOTED

NEW MOVEABLE WALL

PARTITIONS BY OWNER

NOTE

THIS DRAWING HAS BEEN COPIED FROM A

PREVIOUS CONSTRUCTION PROJECT AND INDICATES

THE GENERAL ARRANGEMENT OF THE EXISTING

FACILITY. NO GUARANTEE IS MADE, OR SHOULD BE

ASSUMED, AS TO THE COMPLETENESS OR ACCURACY

OF THE INFORMATION SHOWN ON THIS DRAWING.

PARTIES USING THIS INFORMATION SHALL FIELD

VERIFY THE ACCURACY AND COMPLETENESS PRIOR

TO DEMOLITION AND CONSTRUCTION ACTIVITIES.

PROVIDE UPDATED A/V EQUIPMENT AND

COMPONENTS AT THIS AREA PER OWNER'S

REQUIREMENTS. PROVIDE UPDATES TO

ELECTRICAL AND LIGHTING AS REQUIRED

TO ACCOMMODATE NEW WORK.

ACCESS TO EMERGENCY

EGRESS DOOR TO REMAIN

OPEN AT ALL TIMES. PROVIDE

SIGNAGE ON MOVEABLE

PARTITION WALLS TO IDENTIFY

EGRESS PATH ACCESS.

RELOCATE CEILING

COMPONENTS AS REQ'D

TO ACCOMMODATE NEW

AV EQUIPMENT (TYP.)

NEW MOVEABLE

PARTITIONS BY OWNER

APPLICABLE CODES:

2021 MICHIGAN BUILDING CODE (MBC)

2023 NATIONAL ELECTRIC CODE (NEC)

WITH MICHIGAN AMENDMENTS

2021 MICHIGAN MECHANICAL CODE

2021 MICHIGAN PLUMBING CODE

ICC ANSI A117.1 - 2017

2010 ADA STANDARDS FOR ACCESSIBLE DESIGN

CLASSIFICATION OF WORK (MRCEB SECTION 504):

- WORK AREA IS CLASSIFIED AS A LEVEL 1 ALTERATION -

218 SQFT.

- THE REMAINDER OF BUILDING IS UNCHANGED.

- SUM TOTAL OF ALL WORK AREAS DOES NOT EXCEED 50%

OF THE BUILDING AREA.

USE GROUP (302, 303): B, BUSINESS PER MBC SECTION 303.1.2

CONSTRUCTION TYPE (TABLE 601 & 602): EXISTING TO REMAIN

AFFECTED FLOOR AREAS:

FLOOR AREA - 218 SQ. FT.

TRAVEL DISTANCE:

DISTANCE TO AN EXIT ACCESS DOES NOT EXCEED 200 FEET

FOR AREAS CONSTRUCTED UNDER THIS WORK WITH

TWO EXITS.

ACCESSIBILITY:

AFFECTED AREAS ARE NOT REQUIRED TO BE ACCESSIBLE PER

MBC CHAPTER 11, EXCEPTION 1103.2.15.

BUILDING CODE DATA

PROVIDE NEW POWER

AND SUPPORT BLOCKING

AS REQUIRED FOR NEW

MONITOR - VERIFY EXACT

LOCATION IN FIELD WITH

OWNER. REPAIR WALL AS

REQ'D FOR SEAMLESS

APPEARANCE AT VISIBLE

LOCATIONS.

NEW AV EQUIPMENT AT THIS

AREA - CONFIRM EXACT

MOUNTING REQUIREMENTS AND

PROVIDE NEW BLOCKING, POWER

AND DATA AS NECESSARY

AutoCAD SHX Text 2025 Hubbell, Roth & Clark, Inc. All Rights Reserved

AutoCAD SHX Text C

AutoCAD SHX Text V:\202402\20240248\A\Sheets\A-2_Plan.dwg

AutoCAD SHX Text Melchior, Adrianna M.

AutoCAD SHX Text

AutoCAD SHX Text

4/8/2025 3:37 PM

AutoCAD SHX Text 20240248

AutoCAD SHX Text April 2025

AutoCAD SHX Text

ORIGINAL PLOT SIZE: ANSI FULL BLEED D (34.00 X 22.00 INCHES)

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 1/4" = 1'- 0"

AutoCAD SHX Text

PHOTO NO. 03

AutoCAD SHX Text

PHOTO NO. 01

AutoCAD SHX Text

PHOTO NO. 04

AutoCAD SHX Text

PHOTO NO. 02

Sheets and Views
22x34

File details come from the government source that posted it. Updated .