ITB_ENG260395_Tuscawilla_Alum_Treatment_System_Removal_-_Exhibit_C_-_Plan_Set.pdf

PDF 2 MB Posted

Attached to
Tuscawilla Alum Treatment System Removal
Solicitation number
ITB ENG/260395
Issued by
Marion County, Orlando City, Florida

About this file

This is a plan set exhibit file prepared by the City of Ocala, Florida, for Invitation to Bid (ITB) ENG/260395 concerning the demolition and removal of the Tuscawilla Alum Treatment System located at Tuscawilla Park, 475 NE 3rd Street, Ocala, Florida (Parcel ID #28220-000-00). The project requires complete demolition and removal of existing alum stormwater treatment system equipment while preserving the existing building structure and maintaining existing water and power connections serving that building. The scope includes disconnection and abandonment of system utility connections, capping of PVC lines, removal of concrete structures, disconnection of electrical conduit, removal of light poles and trees within demolition limits, backfilling of voids, and site grading to match surrounding areas. A non-mandatory pre-bid meeting and site visit is scheduled for Tuesday, March 17, 2026, at 9:00 a.m. at the project location. Bids are due by April 2, 2026. Contractors must complete substantial work within 60 calendar days and achieve final completion within 7 additional calendar days from the Notice to Proceed, with mobilization required no later than 10 calendar days after notification. Liquidated damages of $100 per calendar day apply for delays beyond the specified completion date.

Qualified bidders must possess a minimum of five years of documented experience in stormwater treatment system equipment demolition, hold a valid Florida General Contractor license, and employ lead-safe practices throughout demolition activities. The contractor must perform a minimum of 60 percent of work with their own forces and provide all materials, labor, and equipment in good working condition. Required bonding includes a 5 percent bid bond and a recorded Public Construction bond equal to the bid amount. Insurance requirements mandate Commercial General Liability ($1,000,000 per occurrence/$2,000,000 aggregate), Commercial Automotive Liability ($1,000,000 combined limit), Workers' Compensation per Florida statutory requirements, and Pollution Liability ($1,000,000 per claim/$2,000,000 aggregate) for three years post-completion. An asbestos survey conducted on February 13, 2026, confirmed no regulated asbestos-containing materials meeting NESHAP thresholds. Contractor pricing must remain valid for a minimum of 90 calendar days after bid receipt, with 5 percent retainage held until project acceptance and final completion. Award will be made to the lowest responsive and responsible bidder meeting all stated requirements. The solicitation documents contain no specific set-aside designations, disadvantaged enterprise preferences, or restrictions limiting bidder eligibility based on business classification, and no incumbent vendors or current contractors are referenced.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

FIGURE SHEET

CHIPLEY

TALLAHASSEE

JACKSONVILLE

ST AUGUSTINE

GAINESVILLE

OCALA

DELAND 4

NEW PORT RICHEY

TAMPA

LAKELAND

MELBOURNE -

COCOA

ORLANDO

BARTOWST PETERSBURG

FT PIERCE

FT MYERS

FT LAUDERDALE

MIAMI

NAPLES

KEY WEST

FORT WALTON

BEACH

PENSACOLA

WEST PALM

BEACH

FLORIDA

TURNPIKE

PANAMA

CITY

LAKE

CITY

DAYTONA

BEACH

SARASOTA -

BRADENTON

BEE LINE

EXPRESSWAY

PROJECT LOCATION

OCALA, MARION COUNTY, FL

PROJECT LOCATION

PARCEL ID#: 28220-000-00

N

CITY ENGINEER'S OFFICE

LOCAL UTILITIES

UTILITY COMPANY PHONE NUMBER EMERGENCY

OCALA PUBLIC WORKS (TRAFFIC) (352) 351-6733

OCALA ELECTRIC UTILITY (352) 351-6650 (352) 351-6666

(LEAVE MESSAGE)

OCALA WATER RESOURCES (352) 351-6772 (352) 351-6775

COX COMMUNICATIONS (888) 269-9693

CENTURYLINK (352) 368-8817

TECO GAS (352) 622-0112 (352) 622-0111

CONTRACT PLANS

INDEX

SHEET NO. SHEET DESCRIPTION

1 KEY SHEET

2 SIGNATURE SHEET

3 DEMOLITION EXHIBIT

4 DEMO NOTES

5 SITE PHOTOS

ITB NO. ENGCIP25-0025

100% PLANS

FOR CONSTRUCTION

DATE: 12/23/2025

1805 NE 30th AVE, BLDG #600

OCALA, FLORIDA 34470

TUSCAWILLA ALUM STATION

REMOVAL

KEY SHEET

DESCRIPTIONDATE DESCRIPTION DATE

R E V I S I O N S

SHEET

No.

PREPARED BY PROJECT No. 25204

PROJECT NAME: TUSCAWILLA ALUM STATION REMOVAL

ENGINEER OF RECORD

AUSTIN H CASH, P.E.

STATE OF FLORIDA PROFESSIONAL

ENGINEER LICENSE NUMBER: 101078

VALID ONLY WITH EMBOSSED SEAL

THE ABOVE NAMED PROFESSIONAL ENGINEER SHALL BE RESPONSIBLE FOR THE FOLLOWING SHEETS IN

ACCORDANCE WITH RULE 61G15-23.004‚ F.A.C.

CITY OF OCALA

CITY ENGINEER'S OFFICE

1805 NE 30TH AVE., BLDG. 300

OCALA, FL 34470

PLAN INDEX

KEY SHEET

SIGNATURE SHEET

DEMOLITION EXHIBIT

DEMO NOTES

SITE PHOTOS

SIGNATURE SHEET

DESCRIPTIONDATE DESCRIPTION DATE

R E V I S I O N S

SHEET

No.

PREPARED BY PROJECT No. 25204

PROJECT NAME: TUSCAWILLA ALUM STATION REMOVAL

ENGINEER OF RECORD

AUSTIN H CASH, P.E.

STATE OF FLORIDA PROFESSIONAL

ENGINEER LICENSE NUMBER: 101078

AutoCAD SHX Text A

AutoCAD SHX Text U

AutoCAD SHX Text S

AutoCAD SHX Text T

AutoCAD SHX Text I

AutoCAD SHX Text N

AutoCAD SHX Text H

AutoCAD SHX Text

AutoCAD SHX Text C

AutoCAD SHX Text A

AutoCAD SHX Text S

AutoCAD SHX Text H

AutoCAD SHX Text P

AutoCAD SHX Text R

AutoCAD SHX Text O

AutoCAD SHX Text F

AutoCAD SHX Text E

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text I

AutoCAD SHX Text O

AutoCAD SHX Text N

AutoCAD SHX Text A

AutoCAD SHX Text L

AutoCAD SHX Text E

AutoCAD SHX Text N

AutoCAD SHX Text G

AutoCAD SHX Text I

AutoCAD SHX Text N

AutoCAD SHX Text E

AutoCAD SHX Text E

AutoCAD SHX Text R

AutoCAD SHX Text F

AutoCAD SHX Text L

AutoCAD SHX Text O

AutoCAD SHX Text R

AutoCAD SHX Text I

AutoCAD SHX Text D

AutoCAD SHX Text A

AutoCAD SHX Text L

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text E

AutoCAD SHX Text N

AutoCAD SHX Text S

AutoCAD SHX Text E

AutoCAD SHX Text No 101078 101078101078

STATE OF

DEMOLITION EXHIBIT

DESCRIPTIONDATE DESCRIPTION DATE

R E V I S I O N S

SHEET

No.

PREPARED BY PROJECT No. 25204

PROJECT NAME: TUSCAWILLA ALUM STATION REMOVAL

REMOVE EXISTING

EQUIPMENT FOR ALUM

TREATMENT SYSTEM

EXISTING POWER

PANEL TO REMAIN

EXISTING WATER SERVICE

LINE TO REMAIN

REMOVE EXISTING

CONCRETE STRUCTURE

REMOVE EXISTING

3" PVC LINE

CAP EXISTING

1" PVC LINES (2)

EXISTING 1"

WATER SERVICE

LINE, WATER

METER AND BFE

TO REMAIN

CAP EXISTING

6" PVC LINE

DISCONNECT AND ABANDON

EXISTING 1" PRGS CONDUIT

CAP EXISTING

1 1/2" PVC LINE

CAP EXISTING

1 1/2" PVC LINE

EXTERIOR DEMOLITION PLAN:

NOT TO SCALE

INTERIOR DEMOLITION PLAN:

NOT TO SCALE

NE 3RD ST.

GENERAL UTILITY NOTE:

ALL EXISTING UTILITY CONNECTIONS AND

METERS SERVING THE EXISTING

BUILDING SHALL REMAIN.

GENERAL ALUM STATION NOTE:

ALL EXISTING UTILITY CONNECTIONS AND

METERS SERVING THE ALUM STATION

SHALL BE DISCONNECTED AND

ABANDONED.

N

ENGINEER OF RECORD

AUSTIN H CASH, P.E.

STATE OF FLORIDA PROFESSIONAL

ENGINEER LICENSE NUMBER: 101078

VALID ONLY WITH EMBOSSED SEAL

EXISTING 12"

WATER MAIN

R E V I S I O N S

SHEET

No.

PREPARED BY PROJECT No. 25204

PROJECT NAME: TUSCAWILLA ALUM STATION REMOVAL

DEMO NOTES

AUSTIN H CASH, P.E.

STATE OF FLORIDA PROFESSIONAL

ENGINEER LICENSE NUMBER: 101078

VALID ONLY WITH EMBOSSED SEAL

DISCLAIMER

This information provided was derived from documents in the possession of the City of Ocala that are readily available. All existing underground utilities should be considered assumed. No warranties, expressed or implied, are provided as to the accuracy of the underground data herein & should be verified to determine exact location.

M

IN

M

IN

AutoCAD SHX Text

1. DEMOLITION IS FOR THE EXISTING ITEMS (MAINLY ABOVE GROUND) WITHIN DEMOLITION LIMITS. DEMOLITION IS FOR THE EXISTING ITEMS (MAINLY ABOVE GROUND) WITHIN DEMOLITION LIMITS. 2. "DEMOLITION ITEM" SHALL REFER TO ANY EXISTING STRUCTURE OR COMPONENT THAT IS TO BE REMOVED. "DEMOLITION ITEM" SHALL REFER TO ANY EXISTING STRUCTURE OR COMPONENT THAT IS TO BE REMOVED. 3. "REMOVE" SHALL REFER TO THE DEMOLITION (OR DISMANTLING) AND REMOVAL OF ANY DEMOLITION ITEM (OR UTILITY) AND THE "REMOVE" SHALL REFER TO THE DEMOLITION (OR DISMANTLING) AND REMOVAL OF ANY DEMOLITION ITEM (OR UTILITY) AND THE HAULING AWAY OF MATERIALS, BY THE CONTRACTOR, TO THE APPROPRIATE DESTINATIONS. 4. THE EXISTING TEMPORARY FENCE IS TO REMAIN IN PLACE DURING AND AFTER THE DEMOLITION PHASE. THE EXISTING TEMPORARY FENCE IS TO REMAIN IN PLACE DURING AND AFTER THE DEMOLITION PHASE. 5. CONSTRUCTION EQUIPMENT MUST MAINTAIN A MINIMUM APPROACH DISTANCE OF 20' FROM ANY OVERHEAD POWER LINES. CONSTRUCTION EQUIPMENT MUST MAINTAIN A MINIMUM APPROACH DISTANCE OF 20' FROM ANY OVERHEAD POWER LINES. 6. ALL ELECTRICAL POWER SUPPLY TO THE DEMOLITION LIMITS IS TO BE PROPERLY DISCONNECTED BY THE CITY OF OCALA BEFORE ALL ELECTRICAL POWER SUPPLY TO THE DEMOLITION LIMITS IS TO BE PROPERLY DISCONNECTED BY THE CITY OF OCALA BEFORE THE ACTUAL DEMOLITION BEGINS. 7. ALL IN GROUND PULL BOXES (ELECTRICAL VAULTS) ARE TO REMAIN. ALL IN GROUND PULL BOXES (ELECTRICAL VAULTS) ARE TO REMAIN. 8. UNDERGROUND UTILITIES THAT ARE TO BE ABANDONED SHALL REMAIN IN PLACE (TO BE COORDINATED WITH CITY OF OCALA, UNDERGROUND UTILITIES THAT ARE TO BE ABANDONED SHALL REMAIN IN PLACE (TO BE COORDINATED WITH CITY OF OCALA, ENGINEERING & WATER RESOURCES) HOWEVER, ALL EXISTING FUNCTIONAL WATER MAINS, THAT ARE CONNECTED TO THE DEMOLITION ITEMS, ARE TO BE: 8.1. CAPPED AT THE NECESSARY AREAS WHERE DISCONNECTION IS MADE, CAPPED AT THE NECESSARY AREAS WHERE DISCONNECTION IS MADE, 8.2. PRESSURE TESTED TO ENSURE THAT THERE ARE NO LEAKS, PRESSURE TESTED TO ENSURE THAT THERE ARE NO LEAKS, 8.3. AND WHERE THERE IS A GAP CAUSED BY THE DEMOLITION, SIMILAR ADDITIONAL MATERIAL IS TO BE ADDED, SO THAT THE AND WHERE THERE IS A GAP CAUSED BY THE DEMOLITION, SIMILAR ADDITIONAL MATERIAL IS TO BE ADDED, SO THAT THE PIPE NETWORK LOOP IS CLOSED AS NECESSARY. 9. ABOVEGROUND UTILITIES, IF APPLICABLE, ARE TO BE REMOVED TO A DEPTH OF 4' BELOW GRADE (MAX.) AND CAPPED AS ABOVEGROUND UTILITIES, IF APPLICABLE, ARE TO BE REMOVED TO A DEPTH OF 4' BELOW GRADE (MAX.) AND CAPPED AS NECESSARY. 10. ALL ATTACHMENTS, OF A DEMOLITION ITEM, ARE TO BE REMOVED. ALL ATTACHMENTS, OF A DEMOLITION ITEM, ARE TO BE REMOVED. 10.1. ATTACHMENTS INCLUDE, BUT ARE NOT LIMITED TO, SUPPORTING STRUCTURES AND ITEMS THAT ARE LOCATED WITHIN, OR ATTACHMENTS INCLUDE, BUT ARE NOT LIMITED TO, SUPPORTING STRUCTURES AND ITEMS THAT ARE LOCATED WITHIN, OR IMMEDIATELY ATTACHED TO, A DEMOLITION ITEM. 11. REMOVE ALL LIGHT POLES WITHIN DEMOLITION LIMITS. REMOVE ALL LIGHT POLES WITHIN DEMOLITION LIMITS. 12. REMOVE ALL TREES WITHIN DEMOLITION LIMITS. REMOVE ALL TREES WITHIN DEMOLITION LIMITS. 13. ALL MATERIALS LISTED IN THE "SCOPE OF WORK" SHOULD BE CONSIDERED ASSUMED. MAY NOT INCLUDE ALL MATERIALS ALL MATERIALS LISTED IN THE "SCOPE OF WORK" SHOULD BE CONSIDERED ASSUMED. MAY NOT INCLUDE ALL MATERIALS PRESENT IN STRUCTURES, ONLY THE BULK OF MATERIALS PRESENT. 14. ALL ENVIRONMENTALLY HAZARDOUS MATERIALS, IF FOUND, ARE TO BE APPROPRIATELY DISPOSED OF SO THAT THEY DO NOT ALL ENVIRONMENTALLY HAZARDOUS MATERIALS, IF FOUND, ARE TO BE APPROPRIATELY DISPOSED OF SO THAT THEY DO NOT POSE ANY THREAT TO THE ENVIRONMENT. 15. ALL DEMOLITION ITEMS, IF APPLICABLE, ARE TO BE REMOVED 4' BELOW GRADE (MAX.) AND WHAT REMAINS IS TO BE BROKEN ALL DEMOLITION ITEMS, IF APPLICABLE, ARE TO BE REMOVED 4' BELOW GRADE (MAX.) AND WHAT REMAINS IS TO BE BROKEN UP TO MEET FLORIDA D.E.P. STANDARDS AS STATED IN THE 'D.E.P. WWTF ABANDONMENT REQUIREMENTS': 16. LEVEL WORK AREA AS NECESSARY. BACK FILL, WITH DIRT, ALL VOIDS CREATED BY THE DEMOLITION. USE CLEAN FILL (FREE LEVEL WORK AREA AS NECESSARY. BACK FILL, WITH DIRT, ALL VOIDS CREATED BY THE DEMOLITION. USE CLEAN FILL (FREE DRAINING). 17. TO KEEP STORM WATER RUNOFF FLOWING ACROSS AND TO THE PROPER DESTINATION, RETURN ALL DISTURBED AREAS TO TO KEEP STORM WATER RUNOFF FLOWING ACROSS AND TO THE PROPER DESTINATION, RETURN ALL DISTURBED AREAS TO GRADE. THE CITY WOULD PREFER THAT THE FULL EXTENT OF THE DEMOLITION LIMITS BE GRADED TO BEST MATCH THE IMMEDIATE SURROUNDING AREA AND/OR THE ELEVATION OF THE EXISTING PARKING AREA (ITEM S ON SHEET 4). 18. SEED, AS NECESSARY, ALL DISTURBED AREAS.SEED, AS NECESSARY, ALL DISTURBED AREAS.

AutoCAD SHX Text

DEMOLITION NOTES

AutoCAD SHX Text

BACKFILLED TRENCH

AutoCAD SHX Text

SPACING OF POSTS TO BE 6'-10' APART

AutoCAD SHX Text FILTER FABRIC MATERIAL (FOR ADDITIONAL STRENGTH, FILTER FABRIC CAN BE ATTATCHED TO A 6" (MAX.) MESH WIRE SCREEN WHICH HAS BEEN FASTENED TO THE POSTS.

AutoCAD SHX Text

APPROXIMATELY 4" BY 4" TRENCH

AutoCAD SHX Text

RUN OFF

AutoCAD SHX Text

WOOD OR STEEL POST

AutoCAD SHX Text

FILTER FABRIC MATERIAL SECURELY FASTENED TO THE POSTS OR USE THE WIRE MESH

AutoCAD SHX Text APPROXIMATELY 8" OF FILTER FABRIC MATERIAL MUST EXTEND INTO A TRENCH AND BE ANCHORED WITH COMPACTED BACKFILL MATERIAL.

AutoCAD SHX Text

DRIVE BOTH POSTS ABOUT 18" INTO THE GROUND AND BURY FLAP.

AutoCAD SHX Text ROTATE BOTH POSTS AT LEASST 180 DEGREES IN A CLOCKWISE DIRECTION TO CREATE A TIGHT SEAL WITH THE FABRIC MATERIAL.

AutoCAD SHX Text

PLACE THE END POST OF THE SECOND FENCE INSIDE THE END POST OF THE FIRST FENCE

AutoCAD SHX Text

ATTATCHING TWO SILT FENCES

AutoCAD SHX Text

DIRECTION OF RUN OFF WATER

TYP. SILT FENCE DETAILS

R E V I S I O N S

SHEET

No.

PREPARED BY PROJECT No. 25204

PROJECT NAME: TUSCAWILLA ALUM STATION REMOVAL

SITE PHOTOS

BUILDING

LAYOUT

AUSTIN H CASH, P.E.

STATE OF FLORIDA PROFESSIONAL

ENGINEER LICENSE NUMBER: 101078

N

ALUM EXHIBIT-1 - KEY SHEET
Sheets and Views
ALUM EXHIBIT-1 - KEY SHEET
ALUM EXHIBIT-2 - SIGNATURE SHEET
Sheets and Views
ALUM EXHIBIT-2 - SIGNATURE SHEET
ALUM EXHIBIT-3 - PLAN EXHIBIT
Sheets and Views
ALUM EXHIBIT-3 - PLAN EXHIBIT
ALUM EXHIBIT-4 - DEMO NOTES
Sheets and Views
4 - DEMO NOTES
ALUM EXHIBIT-5 - SITE PHOTOS
Sheets and Views
ALUM EXHIBIT-5 - SITE PHOTOS

File details come from the government source that posted it. Updated .