This is a construction specification document prepared by the City of Ocala, Florida for ITB# CIP/260231, which involves the construction of a Union Station Restroom with Ticketing Kiosk facility. The project entails the construction of an approximately 500-square-foot structure at the Union Station (SunTran Transfer Station) located at 501 NE 1st Avenue, Ocala, Florida. The proposed facility will include a public restroom, a restroom for City employees, and a ticketing kiosk. A mandatory pre-bid meeting is scheduled for December 18, 2025 at 10:00 AM EST at the project site. All bids must be electronically submitted through www.bidocala.com or www.prorfx.com by the specified due date; submissions by mail, courier, fax, or email are not permitted. The contract is structured as a lump sum bid for complete construction as designed in the attached exhibits.
Contractor eligibility requirements include Florida state certification as a licensed general or building contractor, a minimum of five years of experience in commercial or industrial building construction, and submission of three completed work projects and three verifiable professional references. Bid bond requirements apply to this solicitation. The specification document includes detailed cast-in-place concrete beam design schedules with specific reinforcement bar sizing and placement diagrams, indicating the structural complexity of the project. Funding sources and specific bond amounts are referenced but detailed in separate sections of the complete solicitation documentation accessible through the City's bidding portal.
View the file
Other files
Show all 18
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
AT SPANDREL BEAMS
PLACE TIE HOOKS ON
SLAB SIDE TYP.
SEE SCHEDULE FOR
STIRRUPS AND CAP SIZE
AND SPACING
SEE NOTE 8
PLACE 135° HOOK OF CLOSURE CAP
AT EXTERIOR FACE OF BEAM
"b" "b"
"d
"b"
"d
END SPAN
L1
INTERIOR SPAN
L2
INTERIOR SPAN
L3
CANTILEVER
L4
.3xL1 .3L1 .3xL2 .3xL2 .3Lx3 .3Lx3 .5xL4
WHICHEVER IS GREATER WHICHEVER IS GREATER WHICHEVER IS GREATER
"E" BARS "D" BARS "D" BARS "D" BARS "D" BARS"C" BARS FOR
L1 SPAN
"C" BARS FOR
L2 SPAN
SEE NOTE 8
"B" BARS"G" BARS
0"
2" CL.
0"
NOTE 6
SEE
NOTE 6
SEE
"A" BARS "F" BARS
FOR L1 SPAN
"A" BARS "A" BARS
INTERIOR COLUMN
.2xL TYP. AT
"F" BARS
FOR L2 SPAN
"F" BARS
FOR L3 SPAN
"A" BARS
6"
TYP.
12" WIDE OR LESS INTERIOR BEAMS WIDER THAN 12" SPANDREL BEAMS WIDER THAN 12"
TYPICAL CAST-IN-PLACE CONCRETE BEAM BAR PLACING DIAGRAM
CAST-IN-PLACE CONCRETE BEAM DETAILS
"C" BARS FOR
L3 SPAN
"B" BARS "B" BARS
BAR SIZE
BAR LENGTH
#5 #6 #7 #8 #9
3'-0" 3'-0" 3'-6" 4'-0" 4'-6"
INTERMEDIATE HORIZONTAL REINFORCING
BEAM DEPTH
REINF. EA. FACE
30"≤ d <36" 36"≤ d <46" 46"≤ d <56" 66" AND GREATER
2 #5 3 #5 4 #5 #5@10" O.C.
MAXIMUM NUMBER OF BARS PER LAYER
REBAR
BEAM WIDTH
#6
#7
#8
#9
#10
#11
8"
10"
12"
16"
18"
20"
24"
28"
30"
32"
36"
1. PRECAST PRESTRESSED SOFFIT BEAMS ARE DESIGNATED WITH ULTIMATE MOMENTS (FOOT-KIPS) IN COLUMN "A" AND ULTIMATE SHEARS (KIPS)
IN THE "SPACING EACH END" COLUMN
2. IN PRECAST SOFFIT BEAMS, PLACE "B", "F" AND "G" BARS DIRECTLY ON TOP OF SOFFIT.
3. "C" AND "F" BARS OCCUR AT CONTINUOUS END OF BEAM. IF BOTH ENDS ARE CONTINUOUS, PLACE "C AND "F" BARS AT END OF BEAM ADJACENT TO BEAM WITH THE HIGHER MARK NUMBER. IN THE CASE OF REPETITIVE MARK NUMBERS, PLACE "C" AND "F" BARS AT SUPPORT BETWEEN
IDENTICAL BEAM MARKS.
4. "D" BARS LAP OVER INTERIOR COLUMNS AND EXTEND TO FAR FACE OF COLUMN AND HOOK AT DISCONTINUOUS ENDS. WHERE NECESSARY, SPLICE "D" BARS AT MIDSPAN WITH A MINIMUM 48 BAR DIAMETER LAP SPLICE.
5. PROVIDE "E" AND "G" BARS AT BOTH ENDS OF SINGLE SPAN BEAMS.
6. DEVELOPMENT LENGTH NOTED FOR "F" AND "G" BARS ARE AS FOLLOW:
7. PLACE FIRST STIRRUP 2" FROM FACE OF SUPPORT. SPACE BALANCE OF STIRRUP TIES AS SCHEDULED. SPACES DESIGNATE NUMBER OF SPACES, NOT QUANTITY OF TIES. IN PRECAST SOFFIT BEAMS, SPECIFIED SHEAR OCCURS AT DISTANCE "d" FROM FACE OF SUPPORT. PLACE FIRST STIRRUP 2" FROM END OF SOFFIT, NEXT 4 TIES @6" O.C. (MAX.) AND BALANCE SPACED AT d/2 (MAX.)
8. FOR 30" AND DEEPER BEAMS, PROVIDE THE FOLLOWING INTERMEDIATE HORIZONTAL REINFORCING EVENLY SPACED BETWEEN THE INNERMOST LAYER OF TOP AND BOTTOM REINFORCING, OR TOP OF PRECAST SOFFIT. PROVIDE 36 BAR DIAMETER LAP AT SUPPORTS AND HOOK
DISCONTINUOUS ENDS.
9. FOR BARS SPECIFIED AS "CONTINUOUS", EXTEND BARS TO THE END OF THE BEAM FRAME AND HOOK, U.O.N. WHERE NECESSARY, SPLICE TOP
BARS AT MIDSPAN AND BOTTOM BARS AT SUPPORTS WITH A 48 BAR DIAMETER LAP
10. EXTEND ALL HOOKED BARS TO FACE OF SUPPORT. WHERE NECESSARY, STAGGER ENDS OF HOOKS 2 INCHES
11. ALIGN BARS IN ALL LAYERS VERTICALLY AND SEPARATE MULTIPLE LAYERS OF #7 BARS AND LARGER WITH #8 SPACER BARS AT 48" O.C.
BUNDLE #5 AND #6 BARS VERTICALLY.
BEAM SCHEDULE NOTES
56"≤ d <56"
5 #5
PROVIDE SLAB BOLSTER OR PLASTIC SPACER 4 SIDES (AT TOP
& MID HEIGHT) MIN. TO MAINTAIN REQUIRED CONCRETE COVER
DOWELS TO MATCH COLUMN
REINFORCEMENT
SEE PLAN
WALL FOOTING OR COLUMN FOOTING
STANDARD 90° HOOK
T.O. FOOTING
SEE PLAN
S E
E S
C H
E D
L A
P S
P L
IC
E
EXTEND HORIZ JOINT REINFORCING 4" INTO
TIE COLUMN PER STRUCTURAL NOTES
4 #7 VERTICAL WITH
#3 TIES @8" O.C.
TC-1
/8
16"
TYPICAL TIE COLUMN DIAGRAM
TYP
1 1/2" CLR
C L
EXTEND COLUMN TO UPPERMOST TIE BEAM
AND TERMINATE WITH STANDARD HOOK
AND SCHEDULE
TIE COL PER PLAN
TYPICAL
LAP PER SCHEDULE
TYP.
0"
CORNERS - SINGLE CURTAIN INTERSECTIONS - SINGLE CURTAIN
LAP PER SCHEDULE STD HOOKOUTSIDE AND INSIDE BARS SAME
SIZE AND SPACING AS HORIZONTAL
REINFORCING
2"x4" KEYWAY
TYP.
0"
L A
P P
E R
S C
H E
D U
L E
TYPICAL HORIZONTAL
REINFORCING
CORNERS - DOUBLE CURTAIN INTERSECTIONS - DOUBLE CURTAIN
CORNER BARS, SAME SIZE AND
SPACING AS HORIZONTAL
REINFORCING
CORNER BARS WITH STD HOOKS AT
SAME SIZE AND SPACING AS
HORIZONTAL REINFORCING
STD HOOK
TYP.
0"
S C
H E
D U
L E
L A
P P
E R
NOTE:
ZERO DIMENSION IS USED TO INDICATE THAT THE BARS ARE INTENDED
TO BE PLACED IN THE SAME PLANE
L A
P P
E R
S C
H E
D U
L E
BEAM SCHEDULE
TYPE
ELEV. TOP OF
BEAM
SIZE "b"x"d"
REINFORCING STIRRUPS
REMARKS
BOT. CONT. TOP CONT.
MID.
CONT.
SIZE SPACING EACH END
B-1 10'-4" 7 5/8"x12" 2#5 2#5 #3 @5" O.C.
B-2 10'-4" 7 5/8"x12" 2#5 2#5 #3 @5" O.C.
3/4" = 1'-0"
1 TYPICAL TIE COLUMN DETAIL
3/4" = 1'-0"
2 TYPICAL TIE COLUMN TERMINATION
AT TIE BEAM OR BOND BEAM 3/4" = 1'-0"
3 TYPICAL HORIZONTAL REINFORCING
CONCRETE TIE BEAMS, WALLS AND FOOTINGS
580 Village Blvd., Suite 310 www.bniengineers.com
West Palm Beach, Florida 33409
Tel. (561) 623-7081
Lazaro Alfonso, P.E. FL Reg. No. 69782
BLISS & NYITRAY, INC.
STRUCTURAL ENGINEERS
To the best of the Structural Engineer's knowledge, the Plans and Specifications comply with the applicable minimum building codes.
FL Certificate of Authorization No. 674
FLORIDA LIC No: AR95989
Carbon design & architecture 263 13th Avenue South Suite 375 St. Petersburg, FL 33701 O:: 941.362.4312 W:: www.carbonAE.com
Project No:
PROJECT DATA
Project Na:
CLIENT DATA
Client:
ARCHITECT DATA
ENGINEER DATA
ISSUE + REVISION DATA
ARCHITECTURE SEAL
CHECKED BY
DRAWN BY
PRINTED:24X36 SHEET
ARCH D
BNI Proj. No.23w21
6/24/2024 6:12:08 PM
6/24/2024 6:12:08 PM
S-402
ALL SCHEDULES
100% CD's Set
05.28.2024
24020
OCALA SUNTRAN
RESTROOMS & KIOSK
CITY OF OCALA
501 NE 1st Ave.
Ocala, FL 34470
L.A
S.C
No: Description: Date:
1 BLD24-1291
Building Comments
06/25/2024
| Sheets |
| S-101 - STRUCTURAL NOTES |
| S-111 - ROOF WIND AND WALL DIAGRAM |
| S-402 - ALL SCHEDULES |
| 561-623-7081 | |
| 2024-06-24T20:44:25-0400 | |
| Lazaro Alfonso | |
| This item has been digitally signed and sealed by Lazaro Alfonso, PE (No. 69782), on the date shown below. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. |