This Addendum No. 2, issued by the Town of Cheshire Department of Engineering on October 23, 2026, provides clarifications and modifications to the specifications and contract documents for ITB 2627-04, the Pavilion Replacement at Mixville Park project. The addendum addresses seven vendor questions regarding concrete specifications, removal and replacement of picnic tables, construction safety fencing requirements, pre-staining of structural components, electrical conduit installation, project start date, and worker restroom accessibility. Key responses clarify that the Town of Cheshire Public Works will handle picnic table removal and replacement; safety fencing is not required but may be included in the base bid if the contractor elects to install snow fence; the pavilion structure should be a complete package from the vendor; electrical conduit installation details are specified on plan sheet E-2; the anticipated notice to proceed is end of November or early December with no winter shutdown; and temporary chemical toilets must be provided as the restroom will not be accessible to workers. The project is scheduled to commence as soon as possible following notice to proceed.

The addendum specifies that concrete for footings, slabs, and sidewalks shall meet PCC04462 standards with a compressive strength of 4,400 psi, and all reinforcement shall be ASTM A615 Grade 60 epoxy-coated steel with a yield strength of 60,000 psi. Concrete cover requirements are established at three inches for footing reinforcement and two inches for all other reinforcement. Exposed concrete edges shall be beveled 1 inch by 1 inch unless otherwise dimensioned, and remain-in-place forms are not permitted. The design specifications reference the Connecticut Department of Transportation Form 819 (2024), Supplemental Specifications and Special Provisions dated January 2026, and the AASHTO LRFD Design Specifications, 10th Edition, 2024. No pricing terms, set-asides, or funding information is included in this addendum.

View the file

Other files

Show all 27

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

TOWN OF CHESHIRE

DEPARTMENT OF ENGINEERING

84 South Main Street • Cheshire, Connecticut 06410 203-271-6650 • DPWengineering@cheshirect.gov

PAVILION REPLACEMENT AT MIXVILLE PARK

ITB #2627-04

ADDENDUM NO. 2

October 23, 2026

NOTICE TO ALL BIDDERS:

The attention of all bidders submitting proposals for this ITB is called to the following Addenda to the specifications and plans. The items set forth herein, whether of omission, addition or substitution are to be included in, and form part of the specifications and plans of the above-named project for bids to be received as advertised.

The following clarifications, modifications, deletions and additions are hereby incorporated into and become part of the Contract Documents.

RESPONSES TO QUESTIONS RECEIVED:

Question 1: Can you provide specs for the type of concrete for the slab and sidewalks?

Response 1: See attached Notes & Specifications for concrete and reinforcing steel.

Question 2: Who will be responsible for removing/ putting back the existing picnic tables?

Response 2: Town of Cheshire Public Works will remove and replace the existing picnic tables.

Question 3: Will a construction safety fence be required? If yes, chain-link or ‘snow’ fence type?

Response 3: A safety fence will not be required. If the contractor wishes to install one, a snow fence will be acceptable and shall be included the base bid for this.

Question 4: Are the posts, beams, and tongue & groove roof decking to be pre-stained/ polyurethane?

If yes, by who?

Response 4: The structure should be a complete package from the vendor.

Question 5: Can you clarify how the electrical conduits are to be handled for the new outlets and pendant lights. Can we assume we can surface mount the conduits to the posts and purlins to each outlet?

Response 5: Please refer to notes on plan sheet E-2 for installation of conduits, raceways, outlets, and light fixtures.

Question 6: What is the expected start date, winter 2026, or spring 2027?

Response 6: The anticipated notice to proceed will be end of November or early December pending contract execution with the apparent low bidder. The project has no winter shutdown and will be expected to start as soon as possible after notice to proceed.

Question 7: Will the restroom be accessible to workers, or should we have a temporary toilet?

Response 7: The restroom will not be accessible to workers. Please see bid documents for requirements for chemical toilets.

ATTACHMENTS:

1. General Notes for Concrete and Steel

END OF ADDENDUM NO. 2

GENERAL NOTES

SPECIFICATIONS

SPECIFICATIONS:CONNECTICUT DEPARTMENT OF TRANSPORTATION FORM

819 (2024), SUPPLEMENTAL SPECIFICATIONS AND SPECIAL PROVISIONS

DATED JANUARY, 2026.

DESIGN SPECIFICATIONS: AASHTO LRFD DESIGN SPECIFICATIONS, 10TH

EDITION, 2024, AS SUPPLEMENTED BY THE CONNECTICUT DEPARTMENT OF

TRANSPORTATION BRIDGE AND ROADWAY STRUCTURES DESIGN MANUAL,

RELEASE (BRSDM).

DESIGN LOADING

ALLOWABLE DESIGN STRESSES:

PCC04462 f'c = 4,400 psi

THE SPECIFIED CONCRETE STRENGTH USED IN DESIGN, f'c, OF THE

CONCRETE COMPONENTS IS NOTED ABOVE. THE MINIMUM COMPRESSIVE

STRENGTH OF THE CONCRETE IN THE CONSTRUCTED COMPONENTS SHALL

CONFORM TO THE REQUIREMENTS OF "SECTION 6.01 CONCRETE FOR

STRUCTURES".

REINFORCEMENT

(ASTM A615 GRADE 60) fy = 60000 psi

CONCRETE NOTES:

PCC04462: SHALL BE USED FOR CONCRETE FOOTINGS, SLAB AND SIDEWALK.

REMAIN-IN-PLACE FORMS: THE USE OF REMAIN-IN-PLACE FORMS ON THIS

STRUCTURE IS NOT ALLOWED.

EXPOSED EDGES: EXPOSED EDGES OF CONCRETE SHALL BE BEVELED 1"X1"

UNLESS DIMENSIONED OTHERWISE.

CONCRETE COVER: ALL FOOTING REINFORCEMENT SHALL HAVE THREE

INCHES OF COVER. ALL OTHER REINFORCEMENT SHALL HAVE TWO INCHES

OF COVER UNLESS DIMENSIONED OTHERWISE.

REINFORCEMENT: ALL REINFORCEMENT SHALL BE ASTM A615 GRADE 60 –