Summary of Issued for Bid Drawings - Iowa Army National Guard MVSB1 Alteration
This document set comprises issued-for-bid architectural, mechanical, and electrical drawings for the Motor Vehicle Storage Building 1 (MVSB1) alteration project at the Clinton Readiness Center, 1200 13th Avenue North, Clinton, Iowa 52732, under the jurisdiction of the Iowa Army National Guard. The project involves comprehensive alterations to convert existing space into a climate-controlled storage facility for Tactical Water Purification System (TWPS) units, with work including installation of metal building insulation systems on walls and roof, replacement of existing doors with insulated overhead sectional doors, and addition of metal liner panels up to 8 feet above finished floor. The scope encompasses 7,513 square feet of the existing motor vehicle storage facility and includes mechanical systems consisting of three gas unit heaters (30 MBH, 45 MBH, and 30 MBH capacities) positioned at 12 feet above finished floor, new electrical power provisions with updated circuit breaker distribution, and coordination with existing controlled humidity preservation equipment and caging systems that are to remain in place. The drawings reference applicable codes including the 2015 International Existing Building Code, 2015 International Building Code, 2015 International Fire Code, State Mechanical Code, State Plumbing Code, State Electrical Code, and ASHRAE 90.1, with the project classified as a Level 2 alteration requiring compliance with both Chapter 7 (Level 1) and Chapter 8 provisions of the International Existing Building Code.
The drawings identify specific demolition requirements including removal of door panels and hardware, removal of existing overhead door systems, and relocation of fire extinguisher equipment to new unistrut supports. Contractors are required to field-verify existing conditions prior to bidding and construction, coordinate with multiple trades, maintain weather-tight integrity throughout construction, and protect all existing systems and finishes not designated for removal. The project documents include provisions for firestopping assemblies, material isolation for dissimilar metals, protection of roof surfaces during construction with minimum 1/2-inch plywood over 1-inch EPS insulation, and comprehensive patching and finishing of all affected areas to match existing conditions. Professional certifications are provided by licensed Iowa architect Cameron L. Manley (License 06716), electrical engineer Kevin J. Bruxvoort (License 19927), and mechanical engineer Brian A. Steffens (License 22014), all with renewal dates in 2025. Contract number 429C7325 and Iowa Army National Guard Project number 19084049 are referenced throughout the documentation, with bid submission deadline of July 18, 2025, at 1:00 PM CDT.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 00 41 00 Form of Bid.pdf | ||
| 1322481-event.pdf | ||
| 1323392-event.pdf | ||
| 00 11 00 Advertisement for Bids.pdf | ||
| Issued for Bid Specifications.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
N
PROJECT SITE
MVSB 1
CODE SUMMARY
Applicable Codes:
2015 International Existing Building Code 2015 International Building Code 2015 International Fire Code State Mechanical Code State Plumbing Code State Electrical Code
2013 ASHRAE 90.1
Project Description:
Alter the existing Motor Vehicle Storage Building 1 (MVSB1) at Clinton Readiness Center to provide a semiheated tempered space for the Iowa Army National Guard Tactical Water Purification System (TWPS) units which need to be stored inside a storage facility to prevent any residual water in the system from freezing. Alterations consist of adding insulations to the walls and roof, replacing existing doors with insulated doors.
International Existing Building Code Chapter 5 Classification of Work
504.1 Scope
Level 2 alterations include the reconfiguration of space, the addition or elimination of any door or window, the reconfiguration or extension of any system, or the installation of any additional equipment.
504.2 Application
Level 2 alterations shall comply with the provisions of Chapter 7 for Level 1 alterations as well as the provisions of Chapter 8.
Chapter 7 Alterations - Level 1 701 General
Alterations shall not make an existing building less safe than its existing condition.
702 Building Elements and Materials
New finishes shall comply with Chapter 8 of the IBC.
703 Fire Protection
Alterations will maintain the level of fire protection provided.
704 Means of Egress
Alterations will maintain the level of protection provided for means of egress.
705 Accessibility
Alterations shall not reduce or have the effect of reducing accessibility of a facility or portion of a facility.
Chapter 8 Alterations - Level 2 801 General
All new construction elements, components, systems, and spaces shall comply with the requirements of the IBC.
811 Energy Conservation Level 2 alterations to existing buildings or structures are permitted without requiring the entire building or structure to comply with the energy requirements of the IECC or IRC. The alterations shall conform to the energy requirements of the IECC or IRC as they relate to new construction only.
International Building Code Chapter 3 – Use and Occupancy Classification
The use and occupancy classification of the existing building will remain unchanged.
Chapter 5 – General Building Heights and Areas
Existing building height and area to remain unchanged.
Chapter 6 – Types of Construction
The type of construction for the existing building will remain unchanged.
Chapter 7 – Fire and Smoke Protection Features
New construction is minimal.
Chapter 10 – Means of Egress
Means of egress will remain unchanged in the existing building.
0.
8.
S
H
IV
E -H
A T
T E
R Y
.C O
M
BA D E
FC G
SHEET INDEX CERTIFICATIONS
H
BA D E FC G H
Autodesk Revit 2024Autodesk Revit 2024
6/
/2
6:
:2
P
M
A ut od es k D oc s:
//2
IA
N
G
C lin to n
M V
S B
Im p/
-A
-R
-I A
N G
C lin to n M
V S
B Im p.
rv t
1200 13th AVENUE NORTH, CLINTON, IOWA 52732
G000
IO
W
A A
R M
Y N
A T
IO
N
A L
G U
A R
D C
L
IN
T O
N M
V S
B
A
LT
E R
A T
IO
N
Io w a A rm y
N a tio na l G ua rd
3t h
A V
E N
U E
N O
R T
H
C
LI
N T
O N
IO
W A
P R
O
JE
C T
N U
M B
E R
IS
S
U E
D F
O R
B
ID
P
R O
JE
C
T
IS
S U
E D
A T
E
/1
3/
SHEET LIST
SHEET NAME
GENERAL
G000 COVER SHEET
G001 PROJECT GENERAL INFORMATION
ARCHITECTURAL
AD01 DEMOLITION PLANS
A101 FIRST FLOOR PLAN
A200 PHOTOS - GENERAL CONDITIONS
A201 PHOTOS - GENERAL CONDITIONS
A202 PHOTOS - EXISSTING CAGING
Mechanical
M100 MECHANICAL PLAN
Electrical
E000 ELECTRICAL GENERAL INFORMATION
E100 ELECTRICAL POWER PLAN
NOT TO SCALEA1 PROJECT LOCATION
I HEREBY CERTIFY THAT THE PORTION OF THIS TECHNICAL
SUBMISSION DESCRIBED BELOW WAS PREPARED BY ME OR UNDER
MY DIRECT SUPERVISION AND RESPONSIBLE CHARGE. I AM A DULY
LICENSED ARCHITECT UNDER THE LAWS OF THE STATE OF IOWA.
PAGES, SHEETS OR DIVISIONS COVERED BY THIS SEAL
PRINTED OR TYPED NAME
SIGNATURE
MY LICENSE RENEWAL DATE IS JUNE 30,
DATE
ARCHITECT
LICENSE NUMBER
{{t:s;r:y;o:"Architect";w:140;h:25;}}
Cameron L. Manley
ALL G & A SERIES SHEETS
06716
PAGES, SHEETS OR DIVISIONS COVERED BY THIS SEAL
MY LICENSE RENEWAL DATE IS DECEMBER 31,
I HEREBY CERTIFY THAT THIS ENGINEERING DOCUMENT WAS
PREPARED BY ME OR UNDER MY DIRECT SUPERVISION AND THAT I
AM A DULY LICENSED PROFESSIONAL ENGINEER UNDER THE LAWS
OF THE STATE OF IOWA.
{{t:s;r:y;o:"Electrical";w:140;h:25;}}
PRINTED OR TYPED NAME
SIGNATURE DATE
LICENSE NUMBER
Kevin J. Bruxvoort
ALL E SERIES SHEETS
19927
ELECTRICAL ENGINEER
PAGES, SHEETS OR DIVISIONS COVERED BY THIS SEAL
MY LICENSE RENEWAL DATE IS DECEMBER 31,
I HEREBY CERTIFY THAT THIS ENGINEERING DOCUMENT WAS
PREPARED BY ME OR UNDER MY DIRECT SUPERVISION AND THAT I
AM A DULY LICENSED PROFESSIONAL ENGINEER UNDER THE LAWS
OF THE STATE OF IOWA.
{{t:s;r:y;o:"Mechanical";w:140;h:25;}}
PRINTED OR TYPED NAME
SIGNATURE DATE
LICENSE NUMBER
Brian A. Steffens
M100
22014
MECHANICAL ENGINEER
CONTRACT # 429C7325
IANG PROJECT # 19084049
/2
5/
SYMBOLS
& AND
@ AT
# NUMBER or POUND
A
A/E ARCHITECT / ENGINEER
ACP ACOUSTICAL CEILING PANEL
ADA AMERICANS WITH DISABILITIES ACT
ADAAG AMERICANS WITH DISABILITIES ACT
ACCESSIBILITY GUIDELINES
ADD ADDENDUM
ADJ ADJUSTABLE or ADJACENT
ADMIN ADMINISTRATION
AFF ABOVE FINISHED FLOOR
AHJ AUTHORITY HAVING JURISDICTION
AHU AIR HANDLING UNIT
AL or ALUM ALUMINUM
ALT ALTERNATE
AP ACCESS PANEL
APA AMERICAN PLYWOOD ASSOCIATION
APPROX APPROXIMATE (LY)
ASTM AMERICAN SOCIETY FOR TESTING & MATERIALS
AUTO AUTOMATIC (DOOR OPERATOR)
AVE AVENUE
AVG AVERAGE
B
B/O BOTTOM OF
BLDG BUILDING
BLVD BOULEVARD
BRG BEARING
C
CCTV CLOSED CIRCUIT TELEVISION
CG CORNER GUARD
CFCI CONTRACTOR FURNISHED CONTRACTOR
INSTALLED
CFOI CONTRACTOR FURNISHED OWNER INSTALLED
CJ CONSTRUCTION/CONTROL JOINT
CL CENTER LINE
CLG CEILING
CLG HT CEILING HEIGHT
CLR CLEAR (ANCE)
CMU CONCRETE MASONRY UNIT
CO CLEANOUT
COL COLUMN
CONC CONCRETE
CONF CONFERENCE
CONST CONSTRUCTION
CORR CORRIDOR
CPT CARPET
CT CERAMIC TILE
CTRL CONTROL
CF CUBIC FEET
CW COLD WATER
D
DBL DOUBLE
DEG DEGREE
DEMO DEMOLITION/ DEMOLISH
DEPT DEPARTMENT
DF DRINKING FOUNTAIN
DIA DIAMETER
DISP DISPENSER
DIV DIVISION
DN DOWN
DTL DETAIL
DS DOWNSPOUT
DW DISHWASHER
DWG DRAWING
DWGS DRAWINGS
E
EA EACH
EF EPOXY FLOORING or EXHAUST FAN
EJ EXPANSION JOINT
ELEC ELECTRIC / ELECTRICAL
ELEV ELEVATION
EL ELEVATOR
ENGR ENGINEER
EP EPOXY PAINT
EPXY EPOXY
EQ EQUAL
EQUIP EQUIPMENT
EXIST EXISTING
F FDN or FNDN FOUNDATION
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FFE FINISH (ED) FLOOR ELEVATION
FHC FIRE HOSE CABINET
FL FLOOR
FLR FLOOR (ING)
FM FM GLOBAL
FRP FIBERGLASS REINFORCED PANEL
FT FOOT (FEET)
FTG FOOTING
FURN FURNITURE
G GA GAGE or GAUGE
GAL GALVANIZED
GB GRAB BAR
GC GENERAL CONTRACTOR
GFCI GROUND FAULT CIRCUIT INTERRUPTER
GWB GYPSUM WALLBOARD
H
HDWD HARDWOOD
HDWR HARDWARE
HM HOLLOW METAL
HORIZ HORIZONTAL
HR HOUR
HT HEIGHT
HVAC HEATING, VENTILATION, AIR CONDITIONING
HW HOT WATER
I
IBC INTERNATIONAL BUILDING CODE
ICC INTERNATIONAL CODE COUNCIL
ID IDENTIFICATION or INSIDE DIAMETER
IN INCHES
INCL INCLUDE
INFO INFORMATION
J
JAN JANITOR
JC JANITOR'S CLOSET
JST JOIST (S)
JT JOINT
ABBREVIATIONS
K
KO KNOCKOUT
L
LAV LAVATORY
LF LINEAR FOOT
LH LEFT HAND
LHR LEFT HAND REVERSE
LLV LONG LEG VERTICAL
LVL LAMINATED VENEER LUMBER
LVT LUXURY VINYL TILE
M
MAINT MAINTENANCE
MATL MATERIAL
MAX MAXIMUM
MECH MECHANICAL
MEZZ MEZZANINE
MFRG MANUFACTURING
MFR MANUFACTURER
MIC MICROPHONE
MIN MINIMUM or MINUTE
MISC MISCELLANEOUS
MO MASONRY OPENING
MTD MOUNTED
MTL METAL
N
N/A NOT APPLICABLE
NEC NATIONAL ELECTRICAL CODE
NEMA NATIONAL ELECTRICAL MANUFACTURERS
ASSOCIATION
NIC NOT IN CONTRACT
NOM NOMINAL
NRC NOISE REDUCTION COEFFICIENT
NRCA NATIONAL ROOFING CONTRACTORS
ASSOCIATION
NTS NOT TO SCALE
O
OC ON CENTER
OD OUTSIDE DIAMETER
OFCI OWNER FURNISHED CONTRACTOR INSTALLED
OFOI OWNER FURNISHED OWNER INSTALLED
OPP OPPOSITE
OHD OVERHEAD DOOR
P
P PAINT
PERP PERPENDICULAR
PKWY PARKWAY
PL PLATE or PLASTIC LAMINATE
PLAM PLASTIC LAMINATE
PLWD PLYWOOD
PR PAIR
PREFAB PREFABRICATED
PREFIN PREFINISHED
PREP PREPARE (ATION)
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
R R RAD or RADIUS
RCI ROOF CONSULTANTS INSTITUTE
RCP REFLECTED CEILING PLAN
RD ROOF DRAIN
REINF REINFORCE (D) (ING) (MENT)
REQD REQUIRED
RESIL RESILIENT
RF RADIO FREQUENCY
RH RIGHT HAND
RHR RIGHT HAND REVERSE
RM ROOM
RO ROUGH OPENING
VTR VENT THROUGH ROOF
S
SAN SANITARY
SCHED SCHEDULE
SECT SECTION
SF SQUARE FOOT
SHT SHEET REFERRING TO PAGES
SIM SIMILAR
SH SHIVE-HATTERY
SOG SLAB ON GRADE
SPEC(S) SPECIFICATION(S)
SQ SQUARE
SQ IN SQUARE INCH
SS SOLID SURFACE or STAINLESS STEEL ST STREET or STONE
STAG STAGGERED
STC SOUND TRANSMISSION CLASS
STD STANDARD
STL STEEL
STRUC STRUCTURE (AL)
SYM SYMMETRICAL
T
T/O TOP OF
T&G TONGUE AND GROOVE
TAN TANGENT
TBD TO BE DETERMINED
TEL TELEPHONE
TEMP TEMPORARY
THRU THROUGH
TV TELEVISION
TYP TYPICAL
U
UL UNDERWRITERS LABORATORIES
UNO UNLESS NOTED OTHERWISE
V
VB VINYL BASE
VCT VINYL COMPOSITION TILE
VERT VERTICAL
VIF VERIFY IN FIELD
VT VINYL TILE
VTR VENT THROUGH ROOF
VWC VINYL WALL COVERING
W
W WIDTH
W/ WITH
W/O WITHOUT
WC WATER CLOSET or WALL COVERING WT WALL TILE or WEIGHT
WTR WATER
1. COLOR HAS BEEN USED ON THESE DRAWINGS TO ENHANCE
UNDERSTANDING. PRINTING IN COLOR IS RECOMMENDED TO
ENSURE CLARITY.
2. ANY DAMAGE TO AREAS INSIDE OR OUTSIDE OF THE PROJECT
AREA SHALL BE REPAIRED TO THE STATUS PRIOR TO
CONSTRUCTION AT NO COST TO OWNER.
3. THE GENERAL CONTRACTOR SHALL BE ULTIMATELY
RESPONSIBLE FOR ALL CUTTING, SUPPORTING, AND PATCHING
IF NOT COVERED BY A SPECIFIC TRADE.
4. STRUCTURAL STEEL MEMBERS AND DECKING PROFILES, AS
INDICATED ON ARCHITECTURAL DETAILS, ARE DIAGRAMMATIC
AND MAY VARY FROM ACTUAL PROFILES AND SIZES SPECIFIED
IN THE STRUCTURAL DRAWINGS. IN ALL CASES STRUCTURAL
DRAWINGS SHALL GOVERN. FIELD VERIFY EXISTING PROFILE
DIMENSIONS WHEN REQUIRED TO MATCH OR REPLACE
EXISTING. NOTE CHANGES REQUIRED TO ARCHITECTURAL
DETAILS IN SHOP DRAWINGS.
5. PROVIDE FOR PROTECTION OF ANY ROOF SURFACES USED
DURING CONSTRUCTION. PROTECTION IS REQUIRED OVER
FULL EXTENT OF THE WORK AREAS. MINIMUM PROTECTION
CONSISTS OF 1/2” PLYWOOD OVER 1” EPS INSULATION.
6. EACH TRADE SHALL PROVIDE TESTED FIRESTOPPING
ASSEMBLIES FOR PENETRATIONS OF THEIR WORK THROUGH
FIRE-RATED WALLS AND FLOOR/CEILING
ASSEMBLIES. FIRESTOPPING ASSEMBLIES ARE TO BE OF
DESIGNS THAT PROVIDE THE SCHEDULED FIRE RATINGS WHEN
TESTED IN ACCORDANCE WITH ASTM E119, ASTM E814, OR UL
1479, AND ARE TO BE INSTALLED BY INDIVIDUALS TRAINED AND
EXPERIENCED WITH INSTALLATION OF SUCH ASSEMBLIES.
PROVIDE SUBMITTALS TO LOCAL AUTHORITIES AS REQUESTED
7. IF COMPLIANCE WITH TWO OR MORE STANDARDS IS SPECIFIED
AND THE STANDARDS ESTABLISH DIFFERENT OR CONFLICTING
REQUIREMENTS FOR MINIMUM QUANTITIES OR QUALITY
LEVELS, COMPLY WITH THE MOST STRINGENT
REQUIREMENT. REFER UNCERTAINTIES AND REQUIREMENTS
THAT ARE DIFFERENT, BUT APPARENTLY EQUAL, TO
ARCHITECT FOR A DECISION BEFORE PROCEEDING.
8. ABATEMENT WORK WILL BE UNDER SEPARATE CONTRACT.
OBTAIN AND MAINTAIN ON SITE A COMPLETE SET OF
ABATEMENT DOCUMENTS, INCLUDING ADDENDA AND CHANGES
AFTER START OF CONSTRUCTION, FOR REFERENCE AND
COORDINATION BY ALL TRADES. COORDINATE ALL DEMOLITION
AND CONSTRUCTION WORK WITH THE ABATEMENT
CONTRACTOR.
9. OBTAIN AND MAINTAIN A COMPLETE SET OF OWNER-PROVIDED
EQUIPMENT DOCUMENTS, INCLUDING ADDENDA AND CHANGES
AFTER START OF CONSTRUCTION, FOR REFERENCE AND
COORDINATION BY ALL TRADES. COORDINATE WITH
EQUIPMENT INSTALLER ON INSTALLATION OF ALL EQUIPMENT.
10. THE INDICATION OF TYPE AND LOCATION OF EXISTING
CONDITIONS AND MATERIALS IN THE DRAWINGS IS NOT
INTENDED AS EXACT DOCUMENTATION OF IN-PLACE
CONDITIONS. THE CONTRACTOR IS RESPONSIBLE FOR
VERIFYING EXISTING CONDITIONS BEFORE SUBMISSION OF
BIDS. EXISTING CONDITIONS VARYING FROM THOSE SHOWN IN
THE DRAWINGS WILL NOT BE JUSTIFICATION FOR ADDITIONAL
ALLOWANCE TO THE CONTRACTOR. NOTIFY THE ARCHITECT
IMMEDIATELY IF ANY CONDITIONS CONFLICT WITH THE
DRAWINGS.
11. PROTECT ALL BUILDING SYSTEMS, NEW AND EXISTING. COVER
SUPPLY, RETURN, AND EXHAUST AIR GRILLES, AND PROTECT
OTHER SENSITIVE EQUIPMENT FROM ALL ACTIVITIES RELATED
TO THIS CONTRACT. REMOVE PROTECTION AT END OF
CONSTRUCTION.
12. ALL DISSIMILAR METALS SHALL BE ISOLATED FROM EACH
OTHER EVEN IF NOT SPECIFICALLY IDENTIFIED IN THE
CONTRACT DOCUMENTS.
13. ALL CODE-REQUIRED LABELS SUCH AS "UL", “FACTORY
MUTUAL”, OR ANY EQUIPMENT IDENTIFICATION, PERFORMANCE
RATING, NAME, OR NOMENCLATURE PLATES SHALL REMAIN
READABLE AND NOT PAINTED OR COVERED BY OTHER
CONSTRUCTION.
14. STRUCTURAL INFORMATION ON ARCHITECTURAL DRAWINGS IS
FOR REFERENCE ONLY. STRUCTURAL INFORMATION ON
STRUCTURAL DRAWINGS AND SPECIFICATIONS SHALL
GOVERN.
15. ARCHITECTURAL DIMENSIONS AND DESIGN INTENT ARE
INDICATED ON ARCHITECTURAL DRAWINGS. IF THE
INSTALLATION OF EQUIPMENT FROM OTHER TRADES
INTERFERES WITH COMPLIANCE OF THE DESIGN INTENT,
NOTIFY THE ARCHITECT BEFORE PROCEEDING.
16. DO NOT SCALE DRAWINGS; DIMENSIONS GOVERN LOCATION
OF BUILDING ELEMENTS. IF DIMENSIONS ARE NOT AVAILABLE,
CONTACT THE ARCHITECT.
17. WHEN DIMENSIONS ON SMALL SCALE DRAWINGS CONFLICT
WITH THOSE ON LARGE SCALE DRAWINGS, THE LARGE SCALE
DRAWINGS GOVERN.
18. OWNER TO REMOVE FURNISHINGS AND STORED ITEMS AS
REQUIRED FOR NEW CONSTRUCTION.
PROJECT GENERAL INFORMATION
VIEW NUMBER
GENERAL SYMBOLS LEGEND
A1 VIEW NAME
100'-0"
12" = 1'-0" 12"
VIEW SCALE
NORTH ARROW
VIEW NUMBER
SHEET NUMBER
BUILDING SECTION MARK
VIEW NUMBER
SHEET NUMBER
WALL SECTION MARK
VIEW NUMBER
SHEET NUMBER
DETAIL SECTION MARK
VIEW NUMBER
SHEET NUMBER
EXTERIOR ELEVATION MARK
VIEW NUMBER
SHEET NUMBER
INTERIOR ELEVATION MARK
ENLARGED DETAIL MARK
VIEW NUMBER
SHEET NUMBER
KEYNOTE VALUEA00
REVISION NUMBER
REVISION TYPE
EXISTING GRID ID MARK
NEW GRID ID MARK
IDENTIFIED LEVEL NAME
ELEVATION MARK
SPOT ELEVATION MARK
ROOM NAME
101 ROOM NUMBER
A4/A104
VIEW NUMBER / SHEET NUMBER OF
CONTINUING VIEW
MATCHLINE
A1 A101
A1 A101
A1 A101
A1 A101
A1 A101
A1
A1A1
A1
A100
A1 A101
RFI
FIRST FLOOR
100'-0"
N
A P
P R
O V
E D
B Y
D R
A W
N B
Y
IS
S
U E
D F
O R
IS
S
U E
D A
T E
P R
O
JE
C T
N U
M B
E R
F
IE
LD
B
O O
K
0.
8.
S H
IV
E
-H A
T T
E R
Y .C
O M
BA D E
FC G
H
BA D E FC G H
Autodesk Revit 2024Autodesk Revit 2024
6/
/2
6:
:2
P
M
A ut od es k D oc s:
//2
IA
N
G
C lin to n
M V
S B
Im p/
-A
-R
-I A
N G
C lin to n M
V S
B Im p.
rv t
P R
O
JE
C T
G E
N E
R A
L
IN
F O
R M
A T
IO
N
B
ID
A pp ro ve r
A ut ho r
/1
3/
G001
IO
W
A A
R M
Y N
A T
IO
N
A L
G U
A R
D C
L
IN
T O
N M
V S
B
A
LT
E R
A T
IO
N
Io w a A rm y
N a tio na l G ua rd
3t h
A V
E N
U E
N O
R T
H
C
LI
N T
O N
IO
W A
/2
5/
EXISTING WALL PARTITIONS
DEMOLITION PLAN SYMBOLS LEGEND
TEMPORARY WALL PARTITIONS
DEMOLISHED WALL PARTITIONS
EXISTING DOOR
DEMOLISHED DOOR
1. FIELD VERIFY EXISTING CONDITIONS PRIOR TO START OF
DEMOLITION WORK. NOTIFY ARCHITECT IN WRITING OF
DISCREPANCIES BETWEEN WORK SHOWN IN THE DRAWINGS
AND FIELD CONDITIONS ENCOUNTERED.
2. TO PROTECT OWNER AND CONTRACTOR, PHOTOGRAPHICALLY
DOCUMENT EXISTING CONDITIONS TO REMAIN, PRIOR TO
START OF DEMOLITION AND CONSTRUCTION ACTIVITIES. COPY
ARCHITECT AND OWNER ON PHOTOGRAPHIC
DOCUMENTATION.
3. OPEN FLAME EQUIPMENT IS NOT PERMITTED FOR REMOVAL OF
EXISTING WORK WITHOUT SPECIFIC WRITTEN PERMISSION
FROM THE OWNER.
4. COORDINATE WITH OWNER ANY ITEMS TO BE SALVAGED.
5. OWNER WILL REMOVE ALL NON-FIXED FURNISHINGS AND
EQUIPMENT FROM THE CONSTRUCTION AREA PRIOR TO START
OF CONSTRUCTION UNLESS NOTED OTHERWISE.
6. MAINTAIN BUILDING IN A WEATHER-TIGHT CONDITION. DO NOT
PERFORM WORK ON EXTERIOR OPENINGS THAT CANNOT BE
COMPLETED OR MADE WEATHER-TIGHT WHEN INCLEMENT
WEATHER IS POSSIBLE.
7. COORDINATE WITH OTHER TRADES CUTTING AND PATCHING
REQUIRED FOR DEMOLITION OR NEW CONSTRUCTION.
8. ANY DEMOLITION OR REMOVAL INDICATED IS SHOWN IN
GENERAL TO PROVIDE THE EXTENT OF DEMOLITION AND IS
NOT TO BE CONSIDERED AS A RECORD DRAWING OF EXISTING
CONDITIONS. THE CONTRACTOR IS RESPONSIBLE FOR IN FIELD
VERIFICATION AND COORDINATION WITH THE ARCHITECT
PRIOR TO COMMENCING WITH STATED WORK.
9. ALL CONSTRUCTION TO REMAIN WHICH IS AFFECTED BY
DEMOLITION SHALL BE PATCHED, BE PROPERLY ALIGNED AND
FINISHED SO AS TO LEAVE NO EVIDENCE OF PATCHING OR
REPAIR. REPAIR OR REPLACE ANY EXISTING CONSTRUCTION,
MATERIALS, OR EQUIPMENT DAMAGED DURING DEMOLITION TO
LIKE NEW CONDITION.
10. THE CONTRACTOR IS TO RETURN SALVAGEABLE MATERIALS,
INCLUDING BUT NOT LIMITED TO DOORS, FRAMES, HARDWARE,
MARBLE, EQUIPMENT, AND LIGHTING FIXTURES TO THE OWNER
AND STOCKPILE THEM IN AN APPROVED CONSTRUCTION AREA.
DISPOSE OF THESE MATERIALS AFTER OWNER'S REVIEW AND
APPROVAL.
11. CONTRACTOR IS RESPONSIBLE FOR PROTECTION OF ALL
FINISHES (TO REMAIN) IN THE PROJECT AREA. COORDINATE
WITH ARCHITECT AND OWNER PRIOR TO DEMOLITION.
12. CONTRACTOR SHALL ENSURE THAT DUST AND DEBRIS ARE
PREVENTED FROM ENTERING THE EXISTING HVAC SYSTEM
AND ADJOINING SPACES WITH TEMPORARY BARRIERS AS
REQUIRED PER THE BUILDING.
13. INDICATION OF NEW MATERIALS SHALL INFER ALL REMOVAL OR
DEMOLITION AND PATCHING REQUIRED OF EXISTING
MATERIALS AND SUBSTRATES FOR PROPER ALIGNMENT.
MATCH EXISTING FINISHES.
14. ALL NEW AND EXISTING PENETRATIONS IN EXISTING WALLS,
FLOORS AND CEILING DECKS SHALL BE THE RESPONSIBILITY
OF THE PRIME CONTRACTOR AND SHALL RECEIVE UL AND
FACILITY APPROVED FIRE SEALANT MATERIALS TO MATCH
RATING REQUIREMENT OF AREA BEING PENETRATED.
ARCHITECTURAL DEMOLITION NOTES
A B C D E F
7,513 SF
MVSB 1
AD.01
AD.01
A01.01
E3 A101
AD.02 AD.02 AD.02 AD.02 AD.02
AD.03
A01.17
A P
P R
O V
E D
B Y
D R
A W
N B
Y
IS
S
U E
D F
O R
IS
S
U E
D A
T E
P R
O
JE
C T
N U
M B
E R
F
IE
LD
B
O O
K
0.
8.
S H
IV
E
-H A
T T
E R
Y .C
O M
BA D E
FC G
H
BA D E FC G H
Autodesk Revit 2024Autodesk Revit 2024
6/
/2
6:
:2
P
M
A ut od es k D oc s:
//2
IA
N
G
C lin to n
M V
S B
Im p/
-A
-R
-I A
N G
C lin to n M
V S
B Im p.
rv t
D E
M O
LI
T
IO
N
P
LA
N S
B
ID
C
LM
R C
B
/1
3/
AD01
IO
W
A A
R M
Y N
A T
IO
N
A L
G U
A R
D C
L
IN
T O
N M
V S
B
A
LT
E R
A T
IO
N
Io w a A rm y
N a tio na l G ua rd
3t h
A V
E N
U E
N O
R T
H
C
LI
N T
O N
IO
W A
NORTH
01/8" = 1'-0"D6 FIRST FLOOR DEMOLITION PLAN
12'
KEYNOTES
KEY NOTE
A01.01 EXISTING CAGING TO REMAIN IN PLACE
A01.17 EXISTING CONTROLLED HUMIDITY PRESERVATION
EQUIPMENT TO REMAIN
AD.01 REMOVE DOOR PANEL, DOOR FRAME TO REMAIN,
SALVAGE EXISTING DOOR HARDWARE. HARDWARE TO
BE REINSTALLED WITH NEW DOOR PANEL.
AD.02 REMOVE EXISTING OVERHEAD DOOR SYSTEM
INCLUDING DOOR PANEL AND TRACKS. EXISTING
STRUCTURAL SYSTEM SUPPORTING OVERHEAD DOOR
TO REMAIN.
AD.03 REMOVE FIRE EXTINGUISHER, REINSTALL ON UNISTRUT
SUPPORT
/2
5/
126'-4"
'-0
A B C D E F
7,513 SF
MVSB 1
100 101 102 103
A07.02
A07.03
A08.01
A08.01
A07.01
A07.01
A01.01
E3 A101
A01.01
A07.06
A01.04 A01.04 A01.04 A01.04 A01.04
A01.04
A01.09 A01.09
A08.02
A08.02
A10.01
A01.17
A20
A3
A200F3
A09.02
A01.06
A200C3
A200 C6
A201
C2
A201
E2
A201
C2
A201 A4
A200 G6
A200 E6
DOOR MARK
FLOOR PLAN SYMBOLS LEGEND
CW GLAZED OPENING MARK
1. WHERE STRUCTURAL ELEMENTS INTERFERE WITH FIRE-RATED
PARTITIONS, FRAME TOP OF WALL AROUND STRUCTURAL
ELEMENT.
2. REFER TO DRAWINGS OF ALL TRADES FOR ADDITIONAL
INFORMATION REGARDING ITEMS PENETRATING FLOORS,
WALLS, AND CEILINGS.
3. ALL NEW PARTITIONS ARE DIMENSIONED TO FACE OF STUD,
MASONRY, OR CONCRETE COMPONENT UNLESS NOTED
OTHERWISE. DIMENSIONS TO EXISTING ELEMENTS ARE TO
EXPOSED FACE.
4. ALL ANGLED PARTITIONS SHOWN SHALL BE AT A 45° ANGLE
UNLESS NOTED OTHERWISE.
5. PHOTOS PROVIDED ON SHEETS A200, A201, AND A202 FOR
GENERAL CONDITIONS AND ADDITIONAL OBSTRUCTIONS
INSULATION AND VAPOR BARRIER SYSTEM WILL NEED TO
ACCOUNT FOR.
FLOOR PLAN NOTES
A B C D E F
MVSB 1
A07.04
E3 A101
TYPA01.02
A01.13
A01.12A01.12
A01.12
A01.12A01.12
A201F6
A01.12 A01.12 A01.12 A01.12 A01.12
A07.07 A07.07 A07.07 A07.07 A07.07
100' - 0"
FIRST FLOOR
117' - 0"
B/O ROOF, VIF
RIGID INSULATION WITH 20 GA PREFINISHED
GALV METAL CLOSURE PANEL, WRAP
INSULATION OVER STEM WALL AS NEEDED
TO PROVIDE CONTINUOUS INSULATION
METAL BUILDING INSULATION SYSTEM,
PROVIDE CONTINUOUS INSULATION AND AIR
BARRIER AROUND PERIMETER OF EXISTING
BUILDING, SEE SPECIFICATION. INSTALL PER
MANUFACTURER INSTRUCTIONS.
METAL LINER PANEL, UP TO 8'-0" AFF MIN,
FASTEN TO EXISTING BUILDING STRUCTURE
EXISTING BUILDING STRUCTURE
BEYOND, FIELD VERIFY LOCATION AND
SPACING
EXISTING CONCRETE STEM WALL
EXISTING CONCRETE FLOOR
EXISTING BUILDING STRUCTURE, FIELD
VERIFY LOCATION AND SPACING
EXISTING BUILDING STRUCTURE, FIELD
VERIFY LOCATION AND SPACING
'-0
M
IN
METAL BUILDING ROOF INSULATION SYSTEM
WITH CONTINUOUS PERFORATED MEMBRANE
OVER EXISTING ROOF SYSTEM. PROVIDE
ACCOMMODATIONS TO PREVENT MOISTURE
COLLECTION BETWEEN THE EXISTING AND
NEW SYSTEMS, SEE SPECIFICATION. INSTALL
PER MANUFACTURER INSTRUCTIONS.
EXISTING METAL BUILDING ROOF
INSULATION SYSTEM TO REMAIN
METAL STUD RUNNER TRACK
PRIME RIGID INSULATION AS NECESSARY TO
PROVIDE SURFACE FOR METAL BUILDING
INSULATION SYSTEM TO TIE INTO. PROVIDE
CONTINUOUS VAPOR BARRIER.
F
P E
R S
C H
E D
U
LE
SCHEDULE
PER
OHSF
P E
R S
C H
E D
U
LE
PER SCHEDULE
VISION LITE, LOCATED
NEAR PULL CHAIN
2'-0"
CONT WOOD BLOCKING PER MFR
WEATHER STRIP W/ COLOR
MATCHING FASTENERS
EXISTING METAL CLOSURE
TO REMAIN
DOOR TRACK
OVERHEAD SECTIONAL DOOR;
SEE DOOR SCHEDULE
METAL BUILDING INSULATION SYSTEM
METAL LINER PANEL, UP TO 8'-0" AFF
EXISTING BUILDING STRUCTURE, FIELD
VERIFY LOCATION AND SPACING
EXISTING METAL BUILDING CLADDING
VIF
VIF
OVERHEAD SECTIONAL DOOR
FRAME
WEATHER STRIP W/ COLOR
MATCHING FASTENERS
2x WOOD BLOCKING AS
REQUIRED
20 GA PREFINISHED GALV
METAL CLOSURE FLASHING
W/DRIP EDGE
/2
METAL BUILDING INSULATION SYSTEM
METAL LINER PANEL, UP TO 8'-0" AFF
EXISTING BUILDING STRUCTURE, FIELD
VERIFY LOCATION AND SPACING
EXISTING METAL BUILDING CLADDING
FILL EXISTING STRUCTURAL FRAMING
WITH INSULATION
A P
P R
O V
E D
B Y
D R
A W
N B
Y
IS
S
U E
D F
O R
IS
S
U E
D A
T E
P R
O
JE
C T
N U
M B
E R
F
IE
LD
B
O O
K
0.
8.
S H
IV
E
-H A
T T
E R
Y .C
O M
BA D E
FC G
H
BA D E FC G H
Autodesk Revit 2024Autodesk Revit 2024
6/
/2
3:
:1
P
M
A ut od es k D oc s:
//2
IA
N
G
C lin to n
M V
S B
Im p/
-A
-R
-I A
N G
C lin to n M
V S
B Im p.
rv t
F
IR
S T
F
LO
O R
P
LA
N B
ID
C
LM
R C
B
/1
3/
A101
IO
W
A A
R M
Y N
A T
IO
N
A L
G U
A R
D C
L
IN
T O
N M
V S
B
A
LT
E R
A T
IO
N
Io w a A rm y
N a tio na l G ua rd
3t h
A V
E N
U E
N O
R T
H
C
LI
N T
O N
IO
W A
01/4" = 1'-0"
DOOR PANEL ELEVATIONS
6'
NORTH
01/8" = 1'-0"A6 FIRST FLOOR PLAN
12'
KEYNOTES
KEY NOTE
A01.01 EXISTING CAGING TO REMAIN IN PLACE
A01.02 EXISTING BUILDING STRUCTURE, FIELD VERIFY
LOCATION AND SPACING
A01.04 EXISTING CAGING EXTENDS ABOVE CONCRETE STEM
WALL, SEE PHOTOS OF TYPICAL CAGING EXTENSIONS
ON A202
A01.06 BOX AND CONDUIT TO REMAIN IN PLACE
A01.09 EXISTING CAGING CEILING TO REMAIN OVER AREAS
SECURED BY CAGING WALLS
A01.12 ALL LIGHT FIXTURES AND ASSOCIATED CONDUIT TO
REMAIN, TYPICAL
A01.13 AUDIO EQUIPMENT TO REMAIN
A01.17 EXISTING CONTROLLED HUMIDITY PRESERVATION
EQUIPMENT TO REMAIN
A07.01 FILL EXISTING DOOR FRAME WITH INSULATION
A07.02 METAL BUILDING INSULATION SYSTEM, PROVIDE
CONTINUOUS INSULATION AND AIR BARRIER AROUND
PERIMETER OF EXISTING BUILDING, SEE
SPECIFICATION. INSTALL PER MANUFACTURER
INSTRUCTIONS.
A07.03 RIGID INSULATION WRAP AROUND STEM WALL WITH 20
GA PREFINISHED GALV METAL CLOSURE PANEL
A07.04 METAL BUILDING ROOF INSULATION SYSTEM WITH
CONTINUOUS PERFORATED MEMBRANE OVER
EXISTING ROOF SYSTEM. PROVIDE ACCOMMODATIONS
TO PREVENT MOISTURE COLLECTION BETWEEN THE
EXISTING AND NEW SYSTEMS, SEE SPECIFICATION.
INSTALL PER MANUFACTURER INSTRUCTIONS.
A07.06 METAL LINER PANEL, UP TO 8'-0" MIN, FASTEN TO
EXITING BUILDING STRUCTURE
A07.07 FILL EXISTING STRUCTURAL FRAMING AT OVERHEAD
DOORS WITH INSULATION
A08.01 NEW INSULATED DOOR PANEL, SEE SPECIFICATIONS
FOR NEW HARDWARE REQUIREMENTS.
A08.02 EXISTING DOOR FRAME TO REMAIN, PAINT
A09.02 PROVIDE NEW UNISTRUT SUPPORTS FOR ELECTRICAL
EQUIPMENT, MOUNT NEW SUPPORTS TO FRONT OF
STEEL SYSTEM, ALIGN LOCATION WITH EXISTING
UNISTRUT BEHIND. SEE ELECTRICAL DRAWINGS FOR
TEMPORARY SUPPORT OF CABLE BOARD DURING
CONSTRUCTION
A10.01 REINSTALL EXISTING FIRE EXTINGUISHER, PROVIDE
UNISTRUT FOR REMOUNTING FIRE EXTINGUISHER
NORTH
01/8" = 1'-0"A3 FIRST FLOOR REFLECTED CEILING PLAN
12'
DOOR AND FRAME SCHEDULE
MARK ROOM NAME
OPENING SIZE DOOR FRAME DETAILS
HARDWARE RATING REMARKSWIDTH HEIGHT THICKNESS TYPE MATERIAL GLAZING MTRL-TYPE FINISH HEAD JAMB SILL 100 16' - 4" 16' - 0" 1" OHSF -- -- OHS -- G5/A101 G6/A101 SEE SPEC FIELD VERIFY EXISTING DOOR
OPENING SIZE
101 16' - 4" 16' - 0" 1" OHSF -- -- OHS -- G5/A101 G6/A101 SEE SPEC -- FIELD VERIFY EXISTING DOOR
OPENING SIZE
102 16' - 4" 16' - 0" 1" OHSF -- -- OHS -- G5/A101 G6/A101 SEE SPEC -- FIELD VERIFY EXISTING DOOR
OPENING SIZE
103 16' - 4" 16' - 0" 1" OHSF -- -- OHS -- G5/A101 G6/A101 SEE SPEC -- FIELD VERIFY EXISTING DOOR
OPENING SIZE
104 16' - 4" 16' - 0" 1" OHSF -- -- OHS -- G5/A101 G6/A101 SEE SPEC -- FIELD VERIFY EXISTING DOOR
OPENING SIZE
105 MVSB 1 3' - 0" 7' - 0" 1 3/4" F HM -- EXISTING EXISTING -- -- -- 01 -- FIELD VERIFY EXISTING DOOR
OPENING SIZE
106 MVSB 1 3' - 0" 7' - 0" 1 3/4" F HM -- EXISTING EXISTING -- -- -- 01 -- FIELD VERIFY EXISTING DOOR
OPENING SIZE
01/2" = 1'-0"E3 WALL SECTION
3'
MVSB 1
MVSB 1
MVSB 1
MVSB 1
MVSB 1
01 1/2" = 1'-0"G6 JAMB - OHS
1'
01 1/2" = 1'-0"G5 HEAD - OHS
1'
DOOR HARDWARE GROUPS
GROUP 01
SINGLE SWING DOOR
3 EA. HEAVY DUTY HINGES
1 EA SURFACE MOUNTED CLOSER
1 EA MORTISE LOCKSET
1 SET WEATHERSTRIPPING
1 SET GASKETING
/2
5/
PROVIDE NEW
UNISTRUT SUPPORTS
FOR ELECTRICAL
EQUIPMENT, MOUNT
NEW SUPPORTS TO
FRONT OF STEEL
SYSTEM, ALIGN
LOCATION WITH
EXISTING UNISTRUT
BEHIND. SEE
ELECTRICAL DRAWINGS
FOR TEMPORARY
SUPPORT OF CABLE
BOARD DURING
CONSTRUCTION
OWNER TO REMOVE
FURNISHINGS AS NEEDED FOR
NEW CONSTRUCTION
OWNER TO REMOVE STOCK
MATERIALS
UNISTRUT TO REMAIN IN
PLACE, SEE ELECTRICAL
DRAWINGS FOR EQUIPMENT
COORDINATION
EXISTING CONTROLLED HUMIDITY
PRESERVATION EQUIPMENT TO
REMAIN.
BOX AND CONDUIT TO REMAIN
IN PLACE
CONDUIT TO REMAINCONDUIT TO REMAIN
CONDUIT TO REMAIN
REMOVE FIRE EXTINGUISHER,
REINSTALL ON UNISTRUT
SUPPORT
INSTALL NEW UNISTRUT
SUPPORT, MOUNT NEW
SUPPORT TO FACE OF STEEL
SYSTEM
CAGE EXTENSIONS TO
REMAIN IN PLACE AT BOTH
CAGE WALLS AND CAGE
CEILING
CAGE EXTENSIONS TO
REMAIN IN PLACE AT BOTH
CAGE WALLS AND CAGE
CEILING
1. PHOTOS PROVIDED FOR REFERENCE, FIELD VERIFY EXISTING
CONDITIONS.
2. ALL CAGING, CAGE EXTENSIONS, AND CAGE CEILINGS TO
REMAIN.
3. OWNER TO REMOVE FURNISHINGS AND STORED ITEMS AS
REQUIRED FOR NEW CONSTRUCTION.
4. PHOTOS DEPICT TYPICAL CONDITIONS OF OBSTRUCTIONS TO
THE NEW INSULATION SYSTEM. NOT ALL INSTANCES OF
OBSTRUCTIONS ARE DEPICTED, FIELD VERIFY EXISTING
CONDITIONS.
5. CONTRACTORS ARE SUGGESTED TO REVIEW EXISTING
CONDITIONS PRIOR TO BIDDING. CONTACT OWNER’S
REPRESENTATIVE FOR ACCESS TO FACILITY.”
GENERAL NOTES
A P
P R
O V
E D
B Y
D R
A W
N B
Y
IS
S
U E
D F
O R
IS
S
U E
D A
T E
P R
O
JE
C T
N U
M B
E R
F
IE
LD
B
O O
K
0.
8.
S H
IV
E
-H A
T T
E R
Y .C
O M
BA D E
FC G
H
BA D E FC G H
Autodesk Revit 2024Autodesk Revit 2024
6/
/2
3:
:1
P
M
A ut od es k D oc s:
//2
IA
N
G
C lin to n
M V
S B
Im p/
-A
-R
-I A
N G
C lin to n M
V S
B Im p.
rv t
P H
O T
O S
G
E N
E R
A L
C O
N D
IT
IO
N S
B
ID
C
LM
R C
B
/1
3/
A200
IO
W
A A
R M
Y N
A T
IO
N
A L
G U
A R
D C
L
IN
T O
N M
V S
B
A
LT
E R
A T
IO
N
Io w a A rm y
N a tio na l G ua rd
3t h
A V
E N
U E
N O
R T
H
C
LI
N T
O N
IO
W A
012" = 1'-0"F3 WEST WALL ELEVATION
1.5"012" = 1'-0"E3 WEST ELEVATION
1.5"012" = 1'-0"C3 WEST ELEVATION
1.5"012" = 1'-0"A3 WEST ELEVATION
1.5"
012" = 1'-0"A4 NORTH WALL ELEVATION
1.5" 012" = 1'-0"E4 TYPICAL EXISTING OVERHEAD DOOR JAMB
1.5"012" = 1'-0"C4 TYPICAL EXISTING OVERHEAD DOOR JAMB
1.5" 012" = 1'-0"G4 TYPICAL CAGE POST FLOOR MOUNT
1.5"
012" = 1'-0"C6 EAST WALL ELEVATION
1.5" 012" = 1'-0"E6 EAST WALL ELEVATION - EXISTING COLUMN CONDITION
1.5" 012" = 1'-0"G6 EAST WALL ELEVATION - EXISTING COLUMN CONDITION
1.5"012" = 1'-0"A6 EAST WALL ELEVATION - TYP CAGE END AT WALL
1.5"
/2
5/
EXISTING CAGING TO REMAIN
IN PLACE
ELECTRICAL EQUIPMENT AND
CONDUIT TO REMAIN
OWNER TO REMOVE
FURNISHINGS AS NEEDED FOR
NEW CONSTRUCTION
EXISTING CAGING AND CAGE
CEILING TO REMAIN
EXISTING CAGING AND CAGE
CEILING TO REMAIN
THRESHOLD TO REMAIN
ELECTRICAL EQUIPMENT AND
CONDUIT TO REMAIN
EXISTING DOOR FRAME TO
REMAIN, PAINT
CONDUIT AND SWITCHES TO
REMAIN
ALL LIGHT FIXTURES AND
ASSOCIATED CONDUIT TO
REMAIN, TYPICAL
AUDIO EQUIPMENT TO REMAIN
1. PHOTOS PROVIDED FOR REFERENCE, FIELD VERIFY EXISTING
CONDITIONS.
2. ALL CAGING, CAGE EXTENSIONS, AND CAGE CEILINGS TO
REMAIN.
3. OWNER TO REMOVE FURNISHINGS AND STORED ITEMS AS
REQUIRED FOR NEW CONSTRUCTION.
4. PHOTOS DEPICT TYPICAL CONDITIONS OF OBSTRUCTIONS TO
THE NEW INSULATION SYSTEM. NOT ALL INSTANCES OF
OBSTRUCTIONS ARE DEPICTED, FIELD VERIFY EXISTING
CONDITIONS.
5. CONTRACTORS ARE SUGGESTED TO REVIEW EXISTING
CONDITIONS PRIOR TO BIDDING. CONTACT OWNER’S
REPRESENTATIVE FOR ACCESS TO FACILITY.”
GENERAL NOTES
A P
P R
O V
E D
B Y
D R
A W
N B
Y
IS
S
U E
D F
O R
IS
S
U E
D A
T E
P R
O
JE
C T
N U
M B
E R
F
IE
LD
B
O O
K
0.
8.
S H
IV
E
-H A
T T
E R
Y .C
O M
BA D E
FC G
H
BA D E FC G H
Autodesk Revit 2024Autodesk Revit 2024
6/
/2
3:
:3
P
M
A ut od es k D oc s:
//2
IA
N
G
C lin to n
M V
S B
Im p/
-A
-R
-I A
N G
C lin to n M
V S
B Im p.
rv t
P H
O T
O S
G
E N
E R
A L
C O
N D
IT
IO
N S
B
ID
C
LM
R C
B
/1
3/
A201
IO
W
A A
R M
Y N
A T
IO
N
A L
G U
A R
D C
L
IN
T O
N M
V S
B
A
LT
E R
A T
IO
N
Io w a A rm y
N a tio na l G ua rd
3t h
A V
E N
U E
N O
R T
H
C
LI
N T
O N
IO
W A
012" = 1'-0"A4 SOUTH WALL ELEVATION
1.5" 012" = 1'-0"C4 SOUTH WALL ELEVATION
1.5"
012" = 1'-0"C2 SOUTH WALL ELEVATION - TYP CAGE ENCLOSURE
1.5" 012" = 1'-0"E2 SOUTH WALL ELEVATION - TYP CAGE ENCLOSURE
1.5"
012" = 1'-0"E4 SOUTH WALL ELEVATION
1.5" 012" = 1'-0"F4 SOUTH WALL ELEVATION
1.5"
012" = 1'-0"A2 SOUTH WALL ELEVATION - TYP COLUMN BASE
1.5"
012" = 1'-0"F6 CEILIING VIEW
1.5"012" = 1'-0"C6 CEILING VIEW
1.5"
/2
5/
EXISTING CAGING STEEL TO
REMAIN
1. PHOTOS PROVIDED FOR REFERENCE, FIELD VERIFY EXISTING
CONDITIONS.
2. ALL CAGING, CAGE EXTENSIONS, AND CAGE CEILINGS TO
REMAIN.
3. OWNER TO REMOVE FURNISHINGS AND STORED ITEMS AS
REQUIRED FOR NEW CONSTRUCTION.
4. PHOTOS DEPICT TYPICAL CONDITIONS OF OBSTRUCTIONS TO
THE NEW INSULATION SYSTEM. NOT ALL INSTANCES OF
OBSTRUCTIONS ARE DEPICTED, FIELD VERIFY EXISTING
CONDITIONS.
5. CONTRACTORS ARE SUGGESTED TO REVIEW EXISTING
CONDITIONS PRIOR TO BIDDING. CONTACT OWNER’S
REPRESENTATIVE FOR ACCESS TO FACILITY.”
GENERAL NOTES
012" = 1'-0"D6 SOUTH WALL ELEVATION - TYP CAGE EXTENTION BASE
1.5" 012" = 1'-0"F6 SOUTH WALL ELEVATION - CAGE STEEL
1.5"
012" = 1'-0"D5 SOUTH WALL ELEVATION - TYP CAGE EXTENSION
1.5"012" = 1'-0"B5 SOUTH WALL ELEVATION - TYP CAGE EXTENSIONS
1.5"
012" = 1'-0"B6 SOUTH WALL ELEVATION - CAGE CEILNIG
1.5"
A P
P R
O V
E D
B Y
D R
A W
N B
Y
IS
S
U E
D F
O R
IS
S
U E
D A
T E
P R
O
JE
C T
N U
M B
E R
F
IE
LD
B
O O
K
0.
8.
S H
IV
E
-H A
T T
E R
Y .C
O M
BA D E
FC G
H
BA D E FC G H
Autodesk Revit 2024Autodesk Revit 2024
6/
/2
3:
:4
P
M
A ut od es k D oc s:
//2
IA
N
G
C lin to n
M V
S B
Im p/
-A
-R
-I A
N G
C lin to n M
V S
B Im p.
rv t
P H
O T
O S
E
X
IS
S T
IN
G
C A
G
IN
G B
ID
C
LM
R C
B
/1
3/
A202
IO
W
A A
R M
Y N
A T
IO
N
A L
G U
A R
D C
L
IN
T O
N M
V S
B
A
LT
E R
A T
IO
N
Io w a A rm y
N a tio na l G ua rd
3t h
A V
E N
U E
N O
R T
H
C
LI
N T
O N
IO
W A
012" = 1'-0"B2 SOUTH WALL ELEVATION - CAGE CEILING AT COLUMN
1.5" 012" = 1'-0"D2 SOUTH WALL ELEVATION - CAGE EXTENSION
1.5"
012" = 1'-0"F5 SOUTH WALL ELEVATION - TYP CAGE EXTENSION
1.5"
012" = 1'-0"F2 SOUTH WALL ELEVATION - CAGE EXTENSION
1.5"
/2
5/
1. PIPING IS SHOWN IN SCHEMATIC FORM, ROUTE AS REQUIRED
FOR CLEARANCE. VERIFY ROUTING AND CLEARANCES AND
COORDINATE WITH OTHER TRADES PRIOR TO FABRICATION.
THE CONTRACTOR SHALL PROVIDE COMPLETE FULLY
FUNCTIONAL SYSTEMS.
2. BREAK CONNECTIONS REQUIRED AT ALL MAJOR EQUIPMENT
AND PIPING ITEMS THAT REQUIRE REMOVAL FOR
MAINTENANCE.
3. PIPE REDUCTIONS ON HORIZONTAL PIPING GOING FROM
LARGER TO SMALLER SHALL BE MADE WITH ECCENTRIC
REDUCERS: TOP FLAT FOR LIQUID SYSTEMS, CONCENTRIC
REDUCERS MAY BE USED FOR FLOW GOING FROM SMALL TO
LARGER SIZE PIPE.
4. NEW FLOOR/WALL/CEILING PENETRATIONS REQUIRED FOR
MECHANICAL PIPING INSTALLATION SHALL BE CLEANLY BORED
AT RIGHT ANGLES. AS NEW PIPING IS INSTALLED, NEW PIPING
PENETRATIONS SHALL BE NEATLY CAULKED TO FILL VOID.
WALL PENETRATIONS SHALL BE FINISHED WITH
ESCUTCHEONS.
5. ALL NEW EQUIPMENT AND ACCESSORIES SHALL BE INSTALLED
SO AS TO BE EASILY ACCESSIBLE.
6. CONTRACTOR SHALL PATCH/REPAIR ALL UNUSED OPENINGS
AND MODIFIED FINISH SURFACES. PATCHING SHALL MATCH
MATERIALS, FINISH AND TEXTURE OF ADJACENT SURFACES.
7. ALL WORK WITHIN THE CONTRACT DOCUMENTS, WHICH
INCLUDE THIS DRAWING, SHALL BE COMPLETED IN A SAFE
WORKMANLIKE MANNER AND IN ACCORDANCE WITH ALL
APPLICABLE STATE, LOCAL AND NATIONAL CODES,
REGULATIONS AND ORDINANCES. IF ANY CONFLICTS ARISE
BETWEEN THE CONTRACT DOCUMENTS AND THE APPLICABLE
CODES, REGULATIONS OR ORDINANCE, THE CONTRACTOR
SHALL BE RESPONSIBLE TO HAVE ALL WORK CONFORM TO
THE STRICTER OF SAID REQUIREMENTS.
8. THE CONTRACTOR IS RESPONSIBLE FOR OBTAINING ALL
PERMITS AND INSPECTIONS AS REQUIRED FOR ELECTRICAL,
AND MECHANICAL INSTALLATIONS. IT SHALL BE THE
CONTRACTOR'S RESPONSIBILITY TO PROVIDE BOTH A
COMPLETE AND COMPLIANT INSTALLATION AS MAY BE
DETERMINED BY THE AUTHORITY(S) HAVING JURISDICTION.
9. CONTRACTOR SHALL NOT PROCURE OR FABRICATE ANY
PIPING, DUCTWORK OR OTHER EQUIPMENT WITHOUT FIRST
VERIFYING ALL DIMENSIONS AND CONDITIONS WHETHER
CURRENTLY EXISTING OR NOT. THE CONTRACTOR SHALL BE
RESPONSIBLE FOR ALL WORK, INCLUDING ANY REQUIRED
REWORK.
10. MAINTAIN ALL MANUFACTURER RECOMMENDED EQUIPMENT
SERVICE AND SAFETY CLEARANCES. DO NOT LOCATE ANY
EQUIPMENT OR RUN MATERIALS ABOVE ANY ELECTRICAL
PANELS OR SWITCHGEAR. MAINTAIN ALL NFPA/NEC CODE
REQUIRED CLEARANCES.
11. EACH CONTRACTOR SHALL BE RESPONSIBLE FOR
COORDINATING, SCHEDULING AND SEQUENCING OF THEIR
WORK WITH ALL OTHER TRADES. PROVIDE OFFSETS,
EASEMENTS, OR RELOCATE TO AVOID CONFLICTS WITH WORK
OF OTHER TRADES. FURNISH SUFFICIENT RESOURCES TO
MEET ALL PROJECT MILESTONES AND DEADLINES.
12. CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAINING THE
WATERTIGHT AND WEATHER-PROOF INTEGRITY OF ROOFS,
WALLS AND FLOORS DURING CONSTRUCTION. EACH TRADE
SHALL LOCATE/DIMENSION/COORDINATE THEIR ROOF, FLOOR
AND WALL OPENINGS WITH THE GENERAL CONTRACTOR (GC)
OR CONSTRUCTION MANAGER.
13. PROTECT NEW WORK FROM DAMAGE OR CONTAMINATION.
PROVIDE TEMPORARY PROTECTIVE CAPPING OR TAPED
POLYETHYLENE ENCLOSURES OVER OPEN DUCTWORK AND
PIPING ENDS AND EQUIPMENT. CONTRACTOR SHALL BE
RESPONSIBLE FOR CLEANING MECHANICAL SYSTEMS PRIOR
TO PLACING THEM IN SERVICE.
14. IN A NEAT AND WORKMANLIKE MANNER: PATCH ANY
REMAINING OPENINGS AND FILL EXCESSIVE GAPS; REWORK
AND REFINISH TO MATCH ADJACENT STRUCTURES; FLASH
AND SEAL ALL MECHANICAL AND ELECTRICAL PENETRATIONS
THRU WALLS, CEILINGS, AND FLOORS WITH METAL
FRAMEWORK OR ESCUTCHEONS. ALL OPENINGS SHALL BE
PROPERLY SEALED SO AS TO MEET FIRE RATING NEEDS.
MECHANICAL PIPING
PRESSURE REDUCING VALVE
BALL VALVE
MOTORIZED CONTROLVALVE
ELBOW UP
ELBOW DOWN
PIPE OFFSET UP
PIPE OFFSET DOWN
PIPE CAP
PIPE TEE TURNED UP
PIPE TEE TURNED DOWN
PIPE TEE
PIPE UNION
PIPE TRANSITION
NATURAL GASNG
TO BE DEMOLISHEDNG
EXISTING TO REMAINNG
NG PIPE SIZE, SYSTEM AND FLOW TAG (DIA)
NEW CONNECTION INTO EXISTING PIPE OR DUCT
KEYNOTE
THERMOSTATT
MECHANICAL SYMBOLS LEGEND
GATE VALVE
GUH-1 GUH-2
MVSB 1
7,316.75 SF
GUH-3
1/2" NG1/2" NG1/2" NG
4ø FEA 4ø FEA4ø FEA
30 MBH
5-14" WC
45 MBH
5-14" WC
30 MBH
5-14" WC
4ø CA 4ø CA 4ø CA
1" NG DN
3/4" NG
1/2" NG
3/4" NG
3/4" NG
EXISTING GAS SERVICE
ENTRANCE LOCATED AT
THE ARMORY BUILDING METER
ALL PRESSURE REGULATORS SHALL HAVE
RELIEF VENT PIPING ROUTED TO A SAFE
OUTDOOR LOCATION
GAS UNIT HEATER GUH-1
(30 CFH AT 5-14" WC)
GAS UNIT HEATER GUH-2
(45 CFH AT 5-14" WC)
GAS UNIT HEATER GUH-3
(30 CFH AT 5-14" WC)
1/2" 1/2"
MVSB1 BUILDING
APPROXIMATELY 300 FEET
1" (0.5 PSI)
1" (0.5 PSI)
EXISTING
DEHUMIDIFIER
(51.3 CFH AT MAX
14" WC)
3/4" (0.5 PSI)
3/4"
EXISTING
DEHUMIDIFIER
(51.3 CFH AT MAX
14" WC)
MVSB2 BUILDING
EXISTING
CORAYVAC
(80 CFH AT MAX
14" WC)
ASSUMED LOAD
EXISTING
CORAYVAC
(80 CFH AT MAX
14" WC)
ASSUMED LOAD
3/4"
G
PRESSURE REGULATOR
6" DIRT LEG
SHUT-OFF VALVE
UNION
FLUE STACK
DOUBLE WALL
TYPE B GAS VENT
PROVIDE METAL ROOF
PIPE BOOT W/
ALUMINUM LINED BASE
AT DUCT PENETRATION
THROUGH ROOF.
A P
P R
O V
E D
B Y
D R
A W
N B
Y
IS
S
U E
D F
O R
IS
S
U E
D A
T E
P R
O J E
C T
N U
M B
E R
F
IE
L D
B O
O K
.7
.0
S
H
IV
E -H
A T
T E
R Y
.C O
M
BA D E
FC G
H
BA D E FC G H
Autodesk Revit 2024Autodesk Revit 2024
/1
/2
:0 :5
P
M
A u to d e s k D o c s /2
I A
N G
C lin to n M
V S
B Im p /2
-M
E P
-R -I
A N
G
C lin to n M
V S
B I m p .r v t
M E
C H
A N
IC
A
L P
L A
N
B
ID
T L S
T L S
/1
/2
M100
IO
W
A A
R M
Y N
A T
IO
N
A L
G U
A R
T C
L
IN
T O
N M
V S
B
A L
T E
R A
T
IO
N
Io w a A rm y N a ti o n a l G u a rd th
A v e N
C lin to n
IA
NORTH
1/8" = 1'-0"C5
MECHANICAL PLAN
12'
5. SINGLE STAGE THERMOSTAT.
4. DOWNTURN NOZZLE CD2.
3. SINGLE STAGE GAS VALVE.
2. FOUR POINT SUSPENSION.
1. PROVIDE WITH SEPARATED COMBUSTION CONVERSION KIT
REMARKS:
UNIT HEATER SCHEDULE - GAS
MARK AREA SERVED CFM EAT (°F) LAT (°F)
GAS MOUNTING
HEIGHT (FT) ORIENTATION
FAN MOTOR DATA
DESIGN BASIS REMARKSINPUT (MBH) OUTPUT (MBH) HP VOLTS PHASE DISCONNECT FURNISHED / INSTALLED
GUH-1 MVSB-1 506 40 85 30 24.6 12' - 0" HORIZONTAL 1/6 120 1 MFR REZNOR UBXC
GUH-2 MVSB-1 759 40 85 45 36.9 12' - 0" HORIZONTAL 1/6 120 1 MFR REZNOR UBXC
GUH-3 MVSB-1 506 40 85 30 24.6 12' - 0" HORIZONTAL 1/6 120 1 MFR REZNOR UBXC
NOT TO SCALED6
GAS PIPING SCHEMATIC
NOT TO SCALEG6
GAS UNIT HEATER
/2
5/
1. ALL WORK SHALL BE IN CONFORMANCE WITH THE NATIONAL
ELECTRICAL CODE - LATEST EDITION ADOPTED BY THE STATE,
THE STATE AMENDMENTS, LOCAL/MUNICIPAL CODES AND
ORDINANCES, AND THE AUTHORITY HAVING JURISDICTION.
THE COMPLETE INSTALLATION SHALL BE IN ACCORDANCE
WITH THE ADAAG (AMERICANS WITH DISABILITIES ACT
ACCESSIBILITY GUIDELINES).
2. IT IS THE INTENT OF THESE DOCUMENTS TO COMPLY WITH
THE APPLICABLE CODES. WHERE DISCREPANCIES OCCUR,
NOTIFY THE ENGINEER/ARCHITECT IN WRITING FOR
INTERPRETATION. CORRECT ANY INSTALLATION THAT FAILS
TO COMPLY WITH THE CODES AND STANDARDS AT NO
ADDITIONAL COST TO THE OWNER.
3. CONTRACTOR SHALL PROVIDE ALL WORK NECESSARY
INCLUDING ALL LABOR, MATERIALS, PERMITS, TAXES, FEES,
INSPECTIONS, HARDWARE, AND COST FOR INSTALLATION FOR
A COMPLETE AND OPERATIONAL SYSTEM.
4. ALL MATERIALS FURNISHED BY THE CONTRACTOR SHALL BE
NEW, COMPLETE WITH MANUFACTURER’S GUARANTEE OR
WARRANTY AND SHALL BE LISTED BY A NATIONALLY
RECOGNIZED TESTING LABORATORY (NRTL).
5. COORDINATE ELECTRICAL INSTALLATION WITH ALL TRADES
PRIOR TO INSTALLATION. IF ELECTRICAL WORK INSTALLED
INTERFERES WITH OTHER TRADES AFTER INSTALLATION, THE
CONTRACTOR SHALL MAKE ALL NECESSARY CHANGES TO
CORRECT THE CONDITION AT NO ADDITIONAL COST TO THE
OWNER.
6. DRAWINGS ARE DIAGRAMMATIC. ALL DIMENSIONS SHOWN ARE
APPROXIMATE. CONTRACTOR SHALL VERIFY ALL FURNITURE,
MODULAR FURNITURE, AND EQUIPMENT LOCATIONS WITH
ARCHITECTURAL PLANS, ELEVATIONS AND REVIEWED SHOP
DRAWINGS. PRIOR TO MAKING THE ACTUAL ELECTRICAL
INSTALLATION THIS CONTRACTOR SHALL ADJUST
CONNECTION LOCATIONS TO ACCOMMODATE FURNITURE
AND/OR EQUIPMENT.
7. ALL ELECTRICAL PANELS WITH ANY BRANCH CIRCUIT/LOAD
REVISIONS (DEMOLITION OR NEW WORK) SHALL HAVE A NEW
TYPED UPDATED CIRCUIT DIRECTORY CARD INSTALLED INSIDE
THE DOOR OF THE ELECTRICAL PANEL. THE CONTRACTOR
SHALL VERIFY THAT ALL UNUSED CIRCUIT BREAKERS ARE
TURNED ‘OFF’ AND PROPERLY INDICATED AS ‘SPARE’ ON THE
NEW CIRCUIT DIRECTORY CARD. THE CONTRACTOR SHALL
INSTALL FILLER PLATES WHERE BREAKERS ARE REMOVED AS
PART OF THIS PROJECT OR HAVE BEEN REMOVED
PREVIOUSLY.
8. NO ENERGIZED CONDUCTORS SHALL BE EXPOSED AT
ANYTIME EXCEPT WHEN THE IMMEDIATE AREA IS UNDER THE
SUPERVISION OF A QUALIFIED ELECTRICIAN.
9. WHERE CONDUIT IS SURFACE MOUNTED TO A WALL AND RUN
VERTICALLY DOWN TO A SWITCH/OUTLET BOX, UTILIZE 1-HOLE
OR 2-HOLE CONDUIT STRAPS.
10. REFER TO THE ARCHITECTURAL DRAWINGS FOR LOCATIONS
OF BUILDING EXPANSION JOINTS. ALL CONDUITS CROSSING
EXPANSION JOINTS SHALL BE INSTALLED WITH EXPANSION
FITTINGS, UNLESS THE CONDUIT IS BELOW SLAB IN THE
COMPACTED GRANULAR FILL. EXPANSION FITTINGS SHALL BE
INSTALLED IN ACCORDANCE WITH THE NATIONAL ELECTRICAL
CODE, AND MANUFACTURE'S WRITTEN RECOMMENDATIONS.
11. PENETRATIONS THROUGH FIRE RATED WALLS BY DIVISION 26
CONTRACTOR SHALL BE SEALED WITH APPROPRIATE FIRE
PROOFING MATERIAL TO RESTORE FIRE RATING. REFER TO
ARCHITECTURAL DRAWINGS FOR FIRE RATED WALLS.
12. THE CONTRACTOR SHALL KEEP THE WORK AREA CLEAN OF
ALL DEBRIS ON A DAILY BASIS. ALL NEW MATERIALS AWAITING
INSTALLATION SHALL BE KEPT IN AREAS DESIGNATED BY THE
OWNER.
13. THESE DRAWINGS SHALL NOT BE SCALED TO OBTAIN
DIMENSIONS. REFER TO DIMENSIONED ARCHITECTURAL
FLOOR PLANS. IF THE DIMENSIONS CANNOT BE DETERMINED
BY THE INFORMATION GIVEN, CONTRACTOR SHALL CONTACT
THE ENGINEER FOR ADDITIONAL INFORMATION.
14. PERIODIC SITE OBSERVATION BY THE ENGINEER IS SOLELY
FOR THE PURPOSE OF DETERMINING IF THE WORK OF THE
CONTRACTOR IS PROCEEDING IN ACCORDANCE WITH THE
CONTRACT DOCUMENTS. THIS LIMITED SITE OBSERVATION
SHOULD NOT BE CONSTRUED AS EXHAUSTIVE OR
CONTINUOUS TO CHECK THE QUALITY OR QUANTITY OF THE
WORK, BUT RATHER PERIODIC IN AN EFFORT TO GUARD THE
OWNER AGAINST DEFECTS OR DEFICIENCIES IN THE WORK OF
THE CONTRACTOR.
15. THE INFORMATION CONTAINED ON THE ELECTRICAL
DRAWINGS IS IN ITSELF INCOMPLETE AND VOID UNLESS USED
IN CONJUNCTION WITH ALL OTHER DISCIPLINE DRAWINGS,
THE SPECIFICATIONS, TRADE PRACTICES, OR APPLICABLE
STANDARDS, CODES, ETC., AND SHALL BE CONSIDERED THE
CONTRACT DOCUMENTS AND WITH ALL THEREIN BY
REFERENCE, WHICH THE CONTRACTOR CERTIFIES
KNOWLEDGE OF BY SIGNING THE CONTRACT.
16. CONTRACTOR IS TO ASSUME FULL RESPONSIBILITY,
UNRELIEVED BY REVIEW OF SHOP DRAWINGS OR PERIODIC
OBSERVATION OF CONSTRUCTION, FOR COMPLIANCE WITH
THE CONTRACT DOCUMENTS, FOR DIMENSIONS TO BE
CONFIRMED AND CORRELATED ON THE JOB SITE AND
BETWEEN INDIVIDUAL DRAWINGS OR SETS OF DRAWINGS FOR
FABRICATION PROCESSES AND CONSTRUCTION TECHNIQUES
(INCLUDING EXCAVATION, SHORING, SCAFFOLDING, BRACING,
ERECTION, FORM WORK, ETC.), FOR COORDINATION OF THE
VARIOUS TRADES, AND FOR SAFE CONDITIONS ON THE JOB
SITE. VARIATIONS IN FIELD CONDITIONS RELATIVE TO THE
CONTRACT DOCUMENTS SHALL BE REPORTED TO THE
ENGINEER AS SOON AS THEY ARE FOUND. WORK SHALL NOT
PROGRESS UNTIL WRITTEN PERMISSION FROM THE ENGINEER
IS OBTAINED.
ELECTRICAL
1. LIGHT LINES INDICATE EXISTING WALLS AND EQUIPMENT TO
REMAIN. DASHED LINES INDICATE WALLS, EQUIPMENT, AND
ELECTRICAL ITEMS TO BE REMOVED.
2. COORDINATE PATCHING REQUIREMENTS FOR UNUSED
OPENINGS WITH THE GENERAL CONTRACTOR. GENERAL
CONTRACTOR SHALL PATCH ALL UNUSED OPENINGS.
PATCHWORK SHALL MATCH MATERIALS, FINISH, AND TEXTURE
OF ADJACENT SURFACES.
3. FIRE ALARM - REMOVE EXISTING CEILING MOUNTED DEVICES
TO PERMIT REMOVAL OF CEILING. WALL MOUNTED
NOTIFICATION DEVICES SHALL BE DEMOLISHED. COORDINATE
WORK WITH PROJECT PHASING TO MAINTAIN FIRE ALARM
SYSTEM PROTECTION OF SPACES AT ALL TIMES. INCLUDE
COSTS OF ALL TEMPORARY DEVICES IN THE BID.
4. SECURITY/SURVEILLANCE - EXISTING DEVICES TO BE
REMOVED BY SYSTEMS VENDOR. CONTRACTOR SHALL
REMOVE ASSOCIATED CABLING, ROUGH-IN, AND POWER
WIRING. PRIOR TO ANY DEMOLITION IDENTIFY AND PROTECT
CABLING REQUIRED TO MAINTAIN THE SYSTEM IN AREAS THAT
WILL NOT BE REMODELED.
5. COORDINATE DISPOSAL OF ALL ITEMS NOT REQUESTED AS
SALVAGE BY THE OWNER.
6. TELEPHONE AND DATA HORIZONTAL CABLING SHALL BE
REMOVED COMPLETELY BACK TO THE FIRST REMAINING
DISTRIBUTION FRAME. PROTECT FIBER OPTIC AND COPPER
TRUNK CABLING SERVING DISTRIBUTION RACKS.
7. LIGHTING FIXTURES AND CONTROLS - REMOVE EXISTING
LIGHT FIXTURES, WALL SWITCHES, OCCUPANCY SENSORS,
AND ASSOCIATED WIRING. VERIFY AND MAINTAIN
CONNECTION TO EXISTING LIGHTING THAT WILL NOT BE
REMOVED BUT ARE ON COMMON CIRCUITS WITH ITEMS TO BE
REMOVED.
8. DISCONNECT OUTLETS, WIRING, AND OTHER NOTED
EQUIPMENT TO PERMIT DEMOLITION OF WALLS. VERIFY AND
MAINTAIN CONNECTION TO EXISTING OUTLETS THAT WILL NOT
BE REMOVED BUT ARE ON COMMON CIRCUITS WITH ITEMS TO
BE REMOVED.
9. DRAWINGS DO NOT IDENTIFY ALL OUTLETS, SWITCHES,
CABLING, OR EQUIPMENT TO BE REMOVED. CONTRACTOR
SHALL BECOME FAMILIAR WITH THE SITE PRIOR TO BIDDING
AND INCLUDE LABOR AND MATERIAL NECESSARY FOR
REQUIRED DEMOLITION IN THEIR BID.
10. WIRING SHALL BE REMOVED BACK TO SERVING PANEL.
INSTALLATION OF NEW CONDUCTORS IN EXISTING CONDUITS
WILL BE PERMITTED AS DESCRIBED IN THE DIVISION 26
SPECIFICATIONS.
11. HVAC EQUIPMENT NOTED FOR REMOVAL IS FOR REFERENCE
ONLY. THE ELECTRICAL CONTRACTOR SHALL REVIEW THE
MECHANICAL SYSTEMS DEMOLITION PLANS AND INCLUDE ALL
LABOR AND MATERIAL NECESSARY TO FACILITATE REMOVAL
OF EQUIPMENT AS SHOWN ON THOSE DRAWINGS. THIS SHALL
INCLUDE ALL ITEMS NOTED ON EITHER THE PLUMBING OR
MECHANICAL SERIES OF DRAWINGS.
ELECTRICAL DEMOLITION
ELECTRICAL ABBREVIATIONS
A
A
AC
ACB
AF
AFF
AL
ALT
AM
AS
AT
APPROX
ATC
ATS
AUTO
AUX
AWG
B
BAS
BD
BRKR
BLDG
B/M
BUZ
C
C
CAB
CB
CCTV
CKT
CL
CLG
COMM
CONN
CONC
COND
CONTR
CP
CPT
CR
CT
CU
D
DC
DIA
DIAG
DIM
DISC
DIV
DN
DP
DT
DWG
E
EC
EL
ELEC
EMER
EMT
ENG
EPO
ETM
EWC
EXH
EXIST
F
F
FA
FACP
FC
FDR
FF
FHP
FL
FLEX
FLR
FLUOR
FREQ
AMPERE
ABOVE COUNTER/ALTERNATING CURRENT
AIR CIRCUIT BREAKER
AMPERE RATING OF FUSE
ABOVE FINISHED FLOOR
ALUMINUM
ALTERNATE
AMMETER
AMMETER SWITCH
AMPERE TRIP RATING
APPROXIMATELY
AUTOMATIC TEMPERATURE CONTROL
AUTOMATIC TRANSFER SWITCH
AUTOMATIC
AUXILIARY
AMERICAN WIRE GAUGE
BUILDING AUTOMATION SYSTEM
BUS DUCT
BREAKER
BUILDING
BILL OF MATERIALS
BUZZER
CONTRACTOR
CABINET
CIRCUIT BREAKER
CLOSED CIRCUIT TELEVISION
CIRCUIT
CENTERLINE
CEILING
COMMUNICATIONS CONNECT, CONNECTED,
CONNECTOR
CONCRETE
CONDUCTOR
CONTRACTOR
CONTROL PANEL
CONTROL POWER TRANSFORMER
CONTROL RELAY
CURRENT TRANSFORMER
COPPER
DIRECT CURRENT
DIAMETER
DIAGRAM
DIMMER CONTROL
DISCONNECT
DIVISION
DOWN
DOUBLE POLE
DOUBLE THROW
DRAWING
ELECTRICAL CONTRACTOR
ELEVATION
ELECTRICAL
EMERGENCY
ELECTRICAL METALLIC TUBING
ENGINEER
EMERGENCY POWER OFF
ELAPSED (RUN) TIME METER
ELECTRIC WATER COOLER
EXHAUST
EXISTING
FUSE
FIRE ALARM
FIRE ALARM CONTROL PANEL
FOOTCANDLE
FEEDER
FURNITURE FEED
FRACTIONAL HORSEPOWER
FLOODLIGHT
FLEXIBLE, FLEXIBLE CONDUIT
FLOOR
FLUORESCENT
FREQUENCY
G
GC
GEC
GEN
GFI
GFP
GND
GR
GW
H
HGT
HH
HID
HP
HPS
HTR
HZ
I
IMC
INCAND
INTCONN
J
JB
JCT
K
K
KCMIL
KV
KVA
KVAR
KW
KWH
L
LG
LIM
LPS
LTG
LV
LVSS
M
MAN
MATL
MC
MCC
MCP
MFR
MH
MIC
MLO
MTG
MTR
MTS
MVA
MVAR
MW
MWH
N
NC
NF
NIC
NEC
NEMA
NO
NTS
O
OCB
OPR
OL
GENERAL CONTRACTOR
GROUNDING ELECTRODE CONDUCTOR
GENERATOR
GROUND FAULT CIRCUIT INTERRUPTER
GROUND FAULT PROTECTOR
GROUND, GROUNDING CONDUCTOR
GROUND ROD
GROUND WELL
HEIGHT
HANDHOLE
HIGH INTENSITY DISCHARGE
HORSEPOWER
HIGH PRESSURE SODIUM
HEATER
HERTZ, FREQUENCY IN CYCLES PER SECOND
INTERMEDIATE METALLIC CONDUIT
INCANDESCENT
INTERCONNECTION
JUNCTION BOX
JUNCTION
KEY OPERATED
THOUSAND CIRCULAR MILS
KILOVOLT
KILOVOLT-AMPERE
KILOVOLT-AMPERE REACTIVE
KILOWATT
KILOWATT-HOUR
LENGTH
LIMIT
LOW PRESSURE SODIUM
LIGHT, LIGHTING
LOW VOLTAGE
LOW VOLTAGE SURGE SUPPRESSION
MANUAL
MATERIAL
MECHANICAL CONTRACTOR
MOTOR CONTROL CENTER
MOTOR CIRCUIT PROTECTOR
MANUFACTURER
MANHOLE
MICROPHONE
MAIN LUGS ONLY
MOUNT, MOUNTED, MOUNTING
MOTOR
MANUAL TRANSFER SWITCH
MEGAVOLT-AMPERE
MEGAVOLT-AMPERE REACTIVE
MEGAWATT
MEGAWATT-HOUR
NORMALLY CLOSED
NON-FUSED
NOT IN CONTRACT
NATIONAL ELECTRICAL CODE
NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION
NORMALLY OPEN
NOT TO SCALE
OIL CIRCUIT BREAKER
OPERATOR, OPERATED
THERMAL OVERLOAD PROTECTION
P
P
PB
PC
PF
PFM
PNL
PRI
PS
PT
PVC
PWR
R
R
RC
RECPT
REF
REQD
RGS
S
SA
SCHD
SCHM
SP
SPKR
ST
STA
STBY
SUBSTA
SW
SWBD
SWGR
SYNC
SYS
T
T/
TB
TC
TCC
TDCD
TDCE
TDOD
TDOE
TEL
TEMP
TERM
TSTAT
TV
TYP
U
UG
UNO
UNG
UPS
V
V
VA
VAR
VERT
VFD
VM
VS
W
W W/ W/O
WH
WP
X
XDCR
XFMR
XFR
XMIT
XP
PILOT
LIGHT PUSHBUTTON
PHOTOCELL
POWER FACTOR
POWER FACTOR METER
PANEL
PRIMARY
PRESSURE SWITCH
POTENTIAL TRANSFORMER
POLVINYLCHLORIDE, PVC CONDUIT
POWER
RELAY
REMOTE CONTROL
RECEPTACLE
REFER, REFERENCE
REQUIRED
RIGID GALVANIZED STEEL CONDUIT
SURGE ARRESTER
SCHEDULE
SCHEMATIC
SINGLE POLE
LOUDSPEAKER
SINGLE THROW
STATION
STANDBY
SUBSTATION
SWITCH
SWITCHBOARD
SWITCHGEAR
SYNCHRONIZE, (ING), (ACTION)
SYSTEM
TOP OF
TERMINAL BOARD
TIMECLOCK
TEMPERATURE CONTROL CONTRACTOR
TIME DELAY CLOSE ON DENERGIZATION
TIME DELAY CLOSE ON ENERGIZATION
TIME DELAY OPEN ON DENERGIZATION
TIME DELAY OPEN ON ENERGIZATION
TELEPHONE
TEMPERATURE
TERMINAL
THERMOSTAT
TELEVISION
TYPICAL
UNDERGROUND
UNLESS NOTED OTHERWISE
UNGROUNDED
UNINTERRUPTIBLE POWER SUPPLY
VOLTS
VOLT-AMPERE
VOLT-AMPERE REACTIVE
VERTICAL
VARIABLE FREQUENCY DRIVE
VOLTMETER
VOLTMETER SWITCH
WATTS
WITH
WITHOUT
WATT-HOUR
WEATHERPROOF
TRANSDUCER
TRANSFORMER
TRANSFER
TRANSMIT, TRANSMITTER
EXPLOSION PROOF
UC
OS
LS
S
FS
TS
FB
B
L
L S
FACP
FARP
NAC
EVAC
FTR
FSCP
HVA
TCVR
T R
DR
FR
ARCR
ASCP
ARCM
E
HH
J
TV
N
NCM
NC ANNUN
NCC
K
D
OS
M
T
SURFACE CYLINDER
RECESSED DOWNLIGHT
WALL MOUNTED LIGHT
FLOOD LIGHT
POLE MOUNTED LIGHT
SURFACE LIGHT
SUSPENDED LINEAR
(+ DENOTES POWERED FROM)
RECESSED LINEAR
INDUSTRIAL STRIP LIGHT
TRACK AND TRACK LIGHT
EMERGENCY LIGHT
EXIT SIGN
LIGHT FIXTURE ON EMERGENCY CIRCUIT
SINGLE POLE SWITCH
3-WAY SWITCH
4-WAY SWITCH
KEYED SWITCH
DIMMER SWITCH
OCCUPANCY SENSOR SWITCH
MOMENTARY CONTACT SWITCH
TIMER SWITCH
PUSH BUTTON
DURESS PUSH BUTTON, UNDER COUNTER
DUPLEX RECEPTACLE
DOUBLE DUPLEX RECEPTACLE
FLOOR BOX
DUPLEX RECEPTACLE - CEILING MOUNTED
CLOCK
OCCUPANCY SENSOR
LIGHT LEVEL SENSOR
EXTERIOR PHOTOCELL
SECURITY CAMERA
CONDUIT CONCEALED IN WALL OR OVERHEAD
CONDUIT CONCEALED BELOW FLOOR
CONDUIT TRANSITION UP
CONDUIT TRANSITION DOWN
CONDUIT STUBBED OUT
BRANCH CIRCUIT HOME RUN
CABLE TRAY (TYPE DENOTED)
CONDUIT SLEEVE (SIZE DENOTED)
VOICE/DATA OUTLET (WALL OR CEILING MOUNT)
# - QUANTITY OF RJ-45 JACKS/CABLES.
ONE, UNLESS SHOWN OTHERWISE
W - DENOTES WALL PHONE
WIRELESS ACCESS POINT (WALL OR CEILING MOUNT)
# - QUANTITY OF RJ-45 JACKS/CABLES.
ONE, UNLESS SHOWN OTHERWISE
TELEVISION OUTLET (WALL OR CEILING MOUNT)
SPEAKER (WALL OR CEILING MOUNT)
INTERCOM STATION
KEYNOTE (SEE SCHEDULE)E#
SPRINKLER FLOW SWITCH
SPRINKLER VALVE TAMPER SWITCH
DUCT SMOKE DETECTOR
LINEAR HEAT DETECTOR
REMOTE TEST/STATUS STATION
AUDIO NOTIFICATION DEVICE - CEILING MOUNTED
B = BELL
C = CHIME
H = HORN
S = SPEAKER
AUDIO NOTIFICATION DEVICE - WALL MOUNTED
B = BELL
C = CHIME
H = HORN
S = SPEAKER
VISUAL NOTIFICATION DEVICE - CEILING MOUNTED
VISUAL NOTIFICATION DEVICE - WALL MOUNTED
AUDIO/VISUAL NOTIFICATION DEVICE -
CEILING MOUNTED
B = BELL
C = CHIME
H = HORN
S = SPEAKER
AUDIO/VISUAL NOTIFICATION DEVICE -
WALL MOUNTED
B = BELL
C = CHIME
H = HORN
S = SPEAKER
FIRE ALARM CONTROL PANEL
FIRE ALARM RELAY PANEL
NAC POWER SUPPLY
VOICE EVACUATION PANEL
FIRE ALARM TRANSPONDER
FIRE SUPPRESSION CONTROL PANEL
HVAC PRESSURIZATION PANEL
FIRE ALARM TRANSCEIVER PANEL
BEAM SMOKE DETECTOR
T = TRANSMITTER/RECEIVER
R = REFLECTOR
DOOR HOLDER/HOLD OPEN
SMOKE DAMPER RELEASE
FIRE ALARM SHUT DOWN RELAY
SMOKE DETECTOR
HEAT DETECTOR
AREA OF REFUGE - CALL STATION
AIR SAMPLING CONTROL PANEL
AREA OF REFUGE - MASTER
FIREFIGHTER PHONE
EMERGENCY EXIT SIGN
SPECIAL RECEPTACLE
(CEILING, WALL, AND FLOOR MOUNTED)
BOLLARD
DIRECT POWER CONNECTION -
WALL AND EQUIPMENT
HANDHOLE
JUNCTION BOX
SYMBOL DESCRIPTION
SYMBOL DESCRIPTION SYMBOL DESCRIPTION
SYMBOL DESCRIPTION
SYMBOL DESCRIPTION
SYMBOL DESCRIPTION
PENDANT LIGHT
SIMPLEX RECEPTACLE
SPLIT DUPLEX RECEPTACLE
DUPLEX RECEPTACLE ON EMERGENCY CIRCUIT
DUPLEX RECEPTACLE PLUG LOAD CONTROL
DOUBLE DUPLEX RECEPTACLE ON EMERGENCY CIRCUIT
MOTION DETECTOR (TYPE DENOTED)
DOOR SIGNAL - APARTMENT UNIT
BUZZER
D
BELL
CHIME
NURSE CALL SINGLE PATIENT STATION
37 PIN BED INTERFACE RECEPTACLE
AUXILIARY ALARM STATION, TWO JACK
EMERGENCY PULL CORD STATION
STAFF TERMINAL, TOUCHSCREEN
DUTY STATION
NURSE CALL DOME LIGHT
NURSE CALL MASTER STATION
NURSE CALL EQUIPMENT CABINET
NURSE CALL ANNUNCIATOR PANEL
STAFF ASSIST
CODE BLUE STATION
NURSE CALL STAFF STATION
CARD READER
SYMBOL DESCRIPTION
LIGHTING/CONTROLS
GENERAL POWER
COMMUNICATION/DATA
SECURITY
NURSE CALL
FIRE ALARM
ELECTRICAL SYMBOLS LEGEND
0000 SPECIALTY EQUIPMENT TAG
PL SINGLE POLE SWITCH WITH PILOT LIGHT
DOUBLE DUPLEX RECEPTACLE PLUG LOAD CONTROL
C
EXAMPLE RECEPTACLE TAG
##" - MOUNTING HEIGHT AS INDICATED.
IF OMITTED, 18" OR ABOVE COUNTER
XX - INDICATES RECEPTACLE CONFIGURATION:
GROUND CONNECTION - EXOTHERMIC WELD
GROUND CONNECTION TO STEEL OR STRUCTURE
STATIC GROUND RECEPTACLE (TYPE DENOTED)
GROUND ROD (PLAN VIEW)
LIGHTNING PROTECTION AIR TERMINAL
LIGHTNING PROTECTION CONDUCTOR SPLICE
SYMBOL DESCRIPTION
GROUNDING
XX
AC
GFI
HZ
IG
OC
USB
WP
XP
ABOVE COUNTER (COORDINATE HEIGHT)
GROUND FAULT CIRCUIT INTERRUPTER
HORIZONTALLY MOUNTED
ISOLATED GROUND
OCCUPANCY CONTROLLED
INTEGRAL USB CHARGER
WEATHERPROOF
EXPLOSION PROOF
XX
XX
FIRE ALARM - CONTINUED
MANUAL PULL STATION
GROUND BAR
ANN FIRE ALARM REMOTE ANNUNCIATOR
KEYPAD
REQUEST TO EXIT
SURFACE MOUNTED RECEPTACLE, VARIES PER TYPE
F
L S
L
B
P
RX
J
E
N
B
A
S
D
T
DH
TV
S
E
J
IC
CR
IR
MD
C
DESCRIPTIONSYMBOL
P C
WT WALL MOUNTED TOUCHPAD
# LIGHTING CONTROL DENOTATION
TROFFER LIGHT
POWER - CONTINUED
R
VFD
SURFACE RACEWAY
BRANCH PANEL WITH CLEARANCE
(SURFACE OR RECESS MOUNTED)
ELECTRICAL EQUIPMENT (SWITCHBOARD,
DISTRIBUTION PANEL)
SPECIAL CABINET
TRANSFORMER
DISCONNECT SWITCH
VARIABLE FREQUENCY DRIVE
RELAY
RECEPTACLE ON DROP CORD (DUPLEX SHOWN)
RECEPTACLE ON CORD REEL…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .