Summary of Issued for Bid Drawings - Iowa Army National Guard MVSB1 Alteration

This document set comprises issued-for-bid architectural, mechanical, and electrical drawings for the Motor Vehicle Storage Building 1 (MVSB1) alteration project at the Clinton Readiness Center, 1200 13th Avenue North, Clinton, Iowa 52732, under the jurisdiction of the Iowa Army National Guard. The project involves comprehensive alterations to convert existing space into a climate-controlled storage facility for Tactical Water Purification System (TWPS) units, with work including installation of metal building insulation systems on walls and roof, replacement of existing doors with insulated overhead sectional doors, and addition of metal liner panels up to 8 feet above finished floor. The scope encompasses 7,513 square feet of the existing motor vehicle storage facility and includes mechanical systems consisting of three gas unit heaters (30 MBH, 45 MBH, and 30 MBH capacities) positioned at 12 feet above finished floor, new electrical power provisions with updated circuit breaker distribution, and coordination with existing controlled humidity preservation equipment and caging systems that are to remain in place. The drawings reference applicable codes including the 2015 International Existing Building Code, 2015 International Building Code, 2015 International Fire Code, State Mechanical Code, State Plumbing Code, State Electrical Code, and ASHRAE 90.1, with the project classified as a Level 2 alteration requiring compliance with both Chapter 7 (Level 1) and Chapter 8 provisions of the International Existing Building Code.

The drawings identify specific demolition requirements including removal of door panels and hardware, removal of existing overhead door systems, and relocation of fire extinguisher equipment to new unistrut supports. Contractors are required to field-verify existing conditions prior to bidding and construction, coordinate with multiple trades, maintain weather-tight integrity throughout construction, and protect all existing systems and finishes not designated for removal. The project documents include provisions for firestopping assemblies, material isolation for dissimilar metals, protection of roof surfaces during construction with minimum 1/2-inch plywood over 1-inch EPS insulation, and comprehensive patching and finishing of all affected areas to match existing conditions. Professional certifications are provided by licensed Iowa architect Cameron L. Manley (License 06716), electrical engineer Kevin J. Bruxvoort (License 19927), and mechanical engineer Brian A. Steffens (License 22014), all with renewal dates in 2025. Contract number 429C7325 and Iowa Army National Guard Project number 19084049 are referenced throughout the documentation, with bid submission deadline of July 18, 2025, at 1:00 PM CDT.

View the file

Other files

File Type Posted
00 41 00 Form of Bid.pdf PDF
1322481-event.pdf PDF
1323392-event.pdf PDF
00 11 00 Advertisement for Bids.pdf PDF
Issued for Bid Specifications.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

N

PROJECT SITE

MVSB 1

CODE SUMMARY

Applicable Codes:

2015 International Existing Building Code 2015 International Building Code 2015 International Fire Code State Mechanical Code State Plumbing Code State Electrical Code

2013 ASHRAE 90.1

Project Description:

Alter the existing Motor Vehicle Storage Building 1 (MVSB1) at Clinton Readiness Center to provide a semiheated tempered space for the Iowa Army National Guard Tactical Water Purification System (TWPS) units which need to be stored inside a storage facility to prevent any residual water in the system from freezing. Alterations consist of adding insulations to the walls and roof, replacing existing doors with insulated doors.

International Existing Building Code Chapter 5 Classification of Work

504.1 Scope

Level 2 alterations include the reconfiguration of space, the addition or elimination of any door or window, the reconfiguration or extension of any system, or the installation of any additional equipment.

504.2 Application

Level 2 alterations shall comply with the provisions of Chapter 7 for Level 1 alterations as well as the provisions of Chapter 8.

Chapter 7 Alterations - Level 1 701 General

Alterations shall not make an existing building less safe than its existing condition.

702 Building Elements and Materials

New finishes shall comply with Chapter 8 of the IBC.

703 Fire Protection

Alterations will maintain the level of fire protection provided.

704 Means of Egress

Alterations will maintain the level of protection provided for means of egress.

705 Accessibility

Alterations shall not reduce or have the effect of reducing accessibility of a facility or portion of a facility.

Chapter 8 Alterations - Level 2 801 General

All new construction elements, components, systems, and spaces shall comply with the requirements of the IBC.

811 Energy Conservation Level 2 alterations to existing buildings or structures are permitted without requiring the entire building or structure to comply with the energy requirements of the IECC or IRC. The alterations shall conform to the energy requirements of the IECC or IRC as they relate to new construction only.

International Building Code Chapter 3 – Use and Occupancy Classification

The use and occupancy classification of the existing building will remain unchanged.

Chapter 5 – General Building Heights and Areas

Existing building height and area to remain unchanged.

Chapter 6 – Types of Construction

The type of construction for the existing building will remain unchanged.

Chapter 7 – Fire and Smoke Protection Features

New construction is minimal.

Chapter 10 – Means of Egress

Means of egress will remain unchanged in the existing building.

0.

8.

S

H

IV

E -H

A T

T E

R Y

.C O

M

BA D E

FC G

SHEET INDEX CERTIFICATIONS

H

BA D E FC G H

Autodesk Revit 2024Autodesk Revit 2024

6/

/2

6:

:2

P

M

A ut od es k D oc s:

//2

IA

N

G

C lin to n

M V

S B

Im p/

-A

-R

-I A

N G

C lin to n M

V S

B Im p.

rv t

1200 13th AVENUE NORTH, CLINTON, IOWA 52732

G000

IO

W

A A

R M

Y N

A T

IO

N

A L

G U

A R

D C

L

IN

T O

N M

V S

B

A

LT

E R

A T

IO

N

Io w a A rm y

N a tio na l G ua rd

3t h

A V

E N

U E

N O

R T

H

C

LI

N T

O N

IO

W A

P R

O

JE

C T

N U

M B

E R

IS

S

U E

D F

O R

B

ID

P

R O

JE

C

T

IS

S U

E D

A T

E

/1

3/

SHEET LIST

SHEET NAME

GENERAL

G000 COVER SHEET

G001 PROJECT GENERAL INFORMATION

ARCHITECTURAL

AD01 DEMOLITION PLANS

A101 FIRST FLOOR PLAN

A200 PHOTOS - GENERAL CONDITIONS

A201 PHOTOS - GENERAL CONDITIONS

A202 PHOTOS - EXISSTING CAGING

Mechanical

M100 MECHANICAL PLAN

Electrical

E000 ELECTRICAL GENERAL INFORMATION

E100 ELECTRICAL POWER PLAN

NOT TO SCALEA1 PROJECT LOCATION

I HEREBY CERTIFY THAT THE PORTION OF THIS TECHNICAL

SUBMISSION DESCRIBED BELOW WAS PREPARED BY ME OR UNDER

MY DIRECT SUPERVISION AND RESPONSIBLE CHARGE. I AM A DULY

LICENSED ARCHITECT UNDER THE LAWS OF THE STATE OF IOWA.

PAGES, SHEETS OR DIVISIONS COVERED BY THIS SEAL

PRINTED OR TYPED NAME

SIGNATURE

MY LICENSE RENEWAL DATE IS JUNE 30,

DATE

ARCHITECT

LICENSE NUMBER

{{t:s;r:y;o:"Architect";w:140;h:25;}}

Cameron L. Manley

ALL G & A SERIES SHEETS

06716

PAGES, SHEETS OR DIVISIONS COVERED BY THIS SEAL

MY LICENSE RENEWAL DATE IS DECEMBER 31,

I HEREBY CERTIFY THAT THIS ENGINEERING DOCUMENT WAS

PREPARED BY ME OR UNDER MY DIRECT SUPERVISION AND THAT I

AM A DULY LICENSED PROFESSIONAL ENGINEER UNDER THE LAWS

OF THE STATE OF IOWA.

{{t:s;r:y;o:"Electrical";w:140;h:25;}}

PRINTED OR TYPED NAME

SIGNATURE DATE

LICENSE NUMBER

Kevin J. Bruxvoort

ALL E SERIES SHEETS

19927

ELECTRICAL ENGINEER

PAGES, SHEETS OR DIVISIONS COVERED BY THIS SEAL

MY LICENSE RENEWAL DATE IS DECEMBER 31,

I HEREBY CERTIFY THAT THIS ENGINEERING DOCUMENT WAS

PREPARED BY ME OR UNDER MY DIRECT SUPERVISION AND THAT I

AM A DULY LICENSED PROFESSIONAL ENGINEER UNDER THE LAWS

OF THE STATE OF IOWA.

{{t:s;r:y;o:"Mechanical";w:140;h:25;}}

PRINTED OR TYPED NAME

SIGNATURE DATE

LICENSE NUMBER

Brian A. Steffens

M100

22014

MECHANICAL ENGINEER

CONTRACT # 429C7325

IANG PROJECT # 19084049

/2

5/

SYMBOLS

& AND

@ AT

# NUMBER or POUND

A

A/E ARCHITECT / ENGINEER

ACP ACOUSTICAL CEILING PANEL

ADA AMERICANS WITH DISABILITIES ACT

ADAAG AMERICANS WITH DISABILITIES ACT

ACCESSIBILITY GUIDELINES

ADD ADDENDUM

ADJ ADJUSTABLE or ADJACENT

ADMIN ADMINISTRATION

AFF ABOVE FINISHED FLOOR

AHJ AUTHORITY HAVING JURISDICTION

AHU AIR HANDLING UNIT

AL or ALUM ALUMINUM

ALT ALTERNATE

AP ACCESS PANEL

APA AMERICAN PLYWOOD ASSOCIATION

APPROX APPROXIMATE (LY)

ASTM AMERICAN SOCIETY FOR TESTING & MATERIALS

AUTO AUTOMATIC (DOOR OPERATOR)

AVE AVENUE

AVG AVERAGE

B

B/O BOTTOM OF

BLDG BUILDING

BLVD BOULEVARD

BRG BEARING

C

CCTV CLOSED CIRCUIT TELEVISION

CG CORNER GUARD

CFCI CONTRACTOR FURNISHED CONTRACTOR

INSTALLED

CFOI CONTRACTOR FURNISHED OWNER INSTALLED

CJ CONSTRUCTION/CONTROL JOINT

CL CENTER LINE

CLG CEILING

CLG HT CEILING HEIGHT

CLR CLEAR (ANCE)

CMU CONCRETE MASONRY UNIT

CO CLEANOUT

COL COLUMN

CONC CONCRETE

CONF CONFERENCE

CONST CONSTRUCTION

CORR CORRIDOR

CPT CARPET

CT CERAMIC TILE

CTRL CONTROL

CF CUBIC FEET

CW COLD WATER

D

DBL DOUBLE

DEG DEGREE

DEMO DEMOLITION/ DEMOLISH

DEPT DEPARTMENT

DF DRINKING FOUNTAIN

DIA DIAMETER

DISP DISPENSER

DIV DIVISION

DN DOWN

DTL DETAIL

DS DOWNSPOUT

DW DISHWASHER

DWG DRAWING

DWGS DRAWINGS

E

EA EACH

EF EPOXY FLOORING or EXHAUST FAN

EJ EXPANSION JOINT

ELEC ELECTRIC / ELECTRICAL

ELEV ELEVATION

EL ELEVATOR

ENGR ENGINEER

EP EPOXY PAINT

EPXY EPOXY

EQ EQUAL

EQUIP EQUIPMENT

EXIST EXISTING

F FDN or FNDN FOUNDATION

FE FIRE EXTINGUISHER

FEC FIRE EXTINGUISHER CABINET

FFE FINISH (ED) FLOOR ELEVATION

FHC FIRE HOSE CABINET

FL FLOOR

FLR FLOOR (ING)

FM FM GLOBAL

FRP FIBERGLASS REINFORCED PANEL

FT FOOT (FEET)

FTG FOOTING

FURN FURNITURE

G GA GAGE or GAUGE

GAL GALVANIZED

GB GRAB BAR

GC GENERAL CONTRACTOR

GFCI GROUND FAULT CIRCUIT INTERRUPTER

GWB GYPSUM WALLBOARD

H

HDWD HARDWOOD

HDWR HARDWARE

HM HOLLOW METAL

HORIZ HORIZONTAL

HR HOUR

HT HEIGHT

HVAC HEATING, VENTILATION, AIR CONDITIONING

HW HOT WATER

I

IBC INTERNATIONAL BUILDING CODE

ICC INTERNATIONAL CODE COUNCIL

ID IDENTIFICATION or INSIDE DIAMETER

IN INCHES

INCL INCLUDE

INFO INFORMATION

J

JAN JANITOR

JC JANITOR'S CLOSET

JST JOIST (S)

JT JOINT

ABBREVIATIONS

K

KO KNOCKOUT

L

LAV LAVATORY

LF LINEAR FOOT

LH LEFT HAND

LHR LEFT HAND REVERSE

LLV LONG LEG VERTICAL

LVL LAMINATED VENEER LUMBER

LVT LUXURY VINYL TILE

M

MAINT MAINTENANCE

MATL MATERIAL

MAX MAXIMUM

MECH MECHANICAL

MEZZ MEZZANINE

MFRG MANUFACTURING

MFR MANUFACTURER

MIC MICROPHONE

MIN MINIMUM or MINUTE

MISC MISCELLANEOUS

MO MASONRY OPENING

MTD MOUNTED

MTL METAL

N

N/A NOT APPLICABLE

NEC NATIONAL ELECTRICAL CODE

NEMA NATIONAL ELECTRICAL MANUFACTURERS

ASSOCIATION

NIC NOT IN CONTRACT

NOM NOMINAL

NRC NOISE REDUCTION COEFFICIENT

NRCA NATIONAL ROOFING CONTRACTORS

ASSOCIATION

NTS NOT TO SCALE

O

OC ON CENTER

OD OUTSIDE DIAMETER

OFCI OWNER FURNISHED CONTRACTOR INSTALLED

OFOI OWNER FURNISHED OWNER INSTALLED

OPP OPPOSITE

OHD OVERHEAD DOOR

P

P PAINT

PERP PERPENDICULAR

PKWY PARKWAY

PL PLATE or PLASTIC LAMINATE

PLAM PLASTIC LAMINATE

PLWD PLYWOOD

PR PAIR

PREFAB PREFABRICATED

PREFIN PREFINISHED

PREP PREPARE (ATION)

PSF POUNDS PER SQUARE FOOT

PSI POUNDS PER SQUARE INCH

R R RAD or RADIUS

RCI ROOF CONSULTANTS INSTITUTE

RCP REFLECTED CEILING PLAN

RD ROOF DRAIN

REINF REINFORCE (D) (ING) (MENT)

REQD REQUIRED

RESIL RESILIENT

RF RADIO FREQUENCY

RH RIGHT HAND

RHR RIGHT HAND REVERSE

RM ROOM

RO ROUGH OPENING

VTR VENT THROUGH ROOF

S

SAN SANITARY

SCHED SCHEDULE

SECT SECTION

SF SQUARE FOOT

SHT SHEET REFERRING TO PAGES

SIM SIMILAR

SH SHIVE-HATTERY

SOG SLAB ON GRADE

SPEC(S) SPECIFICATION(S)

SQ SQUARE

SQ IN SQUARE INCH

SS SOLID SURFACE or STAINLESS STEEL ST STREET or STONE

STAG STAGGERED

STC SOUND TRANSMISSION CLASS

STD STANDARD

STL STEEL

STRUC STRUCTURE (AL)

SYM SYMMETRICAL

T

T/O TOP OF

T&G TONGUE AND GROOVE

TAN TANGENT

TBD TO BE DETERMINED

TEL TELEPHONE

TEMP TEMPORARY

THRU THROUGH

TV TELEVISION

TYP TYPICAL

U

UL UNDERWRITERS LABORATORIES

UNO UNLESS NOTED OTHERWISE

V

VB VINYL BASE

VCT VINYL COMPOSITION TILE

VERT VERTICAL

VIF VERIFY IN FIELD

VT VINYL TILE

VTR VENT THROUGH ROOF

VWC VINYL WALL COVERING

W

W WIDTH

W/ WITH

W/O WITHOUT

WC WATER CLOSET or WALL COVERING WT WALL TILE or WEIGHT

WTR WATER

1. COLOR HAS BEEN USED ON THESE DRAWINGS TO ENHANCE

UNDERSTANDING. PRINTING IN COLOR IS RECOMMENDED TO

ENSURE CLARITY.

2. ANY DAMAGE TO AREAS INSIDE OR OUTSIDE OF THE PROJECT

AREA SHALL BE REPAIRED TO THE STATUS PRIOR TO

CONSTRUCTION AT NO COST TO OWNER.

3. THE GENERAL CONTRACTOR SHALL BE ULTIMATELY

RESPONSIBLE FOR ALL CUTTING, SUPPORTING, AND PATCHING

IF NOT COVERED BY A SPECIFIC TRADE.

4. STRUCTURAL STEEL MEMBERS AND DECKING PROFILES, AS

INDICATED ON ARCHITECTURAL DETAILS, ARE DIAGRAMMATIC

AND MAY VARY FROM ACTUAL PROFILES AND SIZES SPECIFIED

IN THE STRUCTURAL DRAWINGS. IN ALL CASES STRUCTURAL

DRAWINGS SHALL GOVERN. FIELD VERIFY EXISTING PROFILE

DIMENSIONS WHEN REQUIRED TO MATCH OR REPLACE

EXISTING. NOTE CHANGES REQUIRED TO ARCHITECTURAL

DETAILS IN SHOP DRAWINGS.

5. PROVIDE FOR PROTECTION OF ANY ROOF SURFACES USED

DURING CONSTRUCTION. PROTECTION IS REQUIRED OVER

FULL EXTENT OF THE WORK AREAS. MINIMUM PROTECTION

CONSISTS OF 1/2” PLYWOOD OVER 1” EPS INSULATION.

6. EACH TRADE SHALL PROVIDE TESTED FIRESTOPPING

ASSEMBLIES FOR PENETRATIONS OF THEIR WORK THROUGH

FIRE-RATED WALLS AND FLOOR/CEILING

ASSEMBLIES. FIRESTOPPING ASSEMBLIES ARE TO BE OF

DESIGNS THAT PROVIDE THE SCHEDULED FIRE RATINGS WHEN

TESTED IN ACCORDANCE WITH ASTM E119, ASTM E814, OR UL

1479, AND ARE TO BE INSTALLED BY INDIVIDUALS TRAINED AND

EXPERIENCED WITH INSTALLATION OF SUCH ASSEMBLIES.

PROVIDE SUBMITTALS TO LOCAL AUTHORITIES AS REQUESTED

7. IF COMPLIANCE WITH TWO OR MORE STANDARDS IS SPECIFIED

AND THE STANDARDS ESTABLISH DIFFERENT OR CONFLICTING

REQUIREMENTS FOR MINIMUM QUANTITIES OR QUALITY

LEVELS, COMPLY WITH THE MOST STRINGENT

REQUIREMENT. REFER UNCERTAINTIES AND REQUIREMENTS

THAT ARE DIFFERENT, BUT APPARENTLY EQUAL, TO

ARCHITECT FOR A DECISION BEFORE PROCEEDING.

8. ABATEMENT WORK WILL BE UNDER SEPARATE CONTRACT.

OBTAIN AND MAINTAIN ON SITE A COMPLETE SET OF

ABATEMENT DOCUMENTS, INCLUDING ADDENDA AND CHANGES

AFTER START OF CONSTRUCTION, FOR REFERENCE AND

COORDINATION BY ALL TRADES. COORDINATE ALL DEMOLITION

AND CONSTRUCTION WORK WITH THE ABATEMENT

CONTRACTOR.

9. OBTAIN AND MAINTAIN A COMPLETE SET OF OWNER-PROVIDED

EQUIPMENT DOCUMENTS, INCLUDING ADDENDA AND CHANGES

AFTER START OF CONSTRUCTION, FOR REFERENCE AND

COORDINATION BY ALL TRADES. COORDINATE WITH

EQUIPMENT INSTALLER ON INSTALLATION OF ALL EQUIPMENT.

10. THE INDICATION OF TYPE AND LOCATION OF EXISTING

CONDITIONS AND MATERIALS IN THE DRAWINGS IS NOT

INTENDED AS EXACT DOCUMENTATION OF IN-PLACE

CONDITIONS. THE CONTRACTOR IS RESPONSIBLE FOR

VERIFYING EXISTING CONDITIONS BEFORE SUBMISSION OF

BIDS. EXISTING CONDITIONS VARYING FROM THOSE SHOWN IN

THE DRAWINGS WILL NOT BE JUSTIFICATION FOR ADDITIONAL

ALLOWANCE TO THE CONTRACTOR. NOTIFY THE ARCHITECT

IMMEDIATELY IF ANY CONDITIONS CONFLICT WITH THE

DRAWINGS.

11. PROTECT ALL BUILDING SYSTEMS, NEW AND EXISTING. COVER

SUPPLY, RETURN, AND EXHAUST AIR GRILLES, AND PROTECT

OTHER SENSITIVE EQUIPMENT FROM ALL ACTIVITIES RELATED

TO THIS CONTRACT. REMOVE PROTECTION AT END OF

CONSTRUCTION.

12. ALL DISSIMILAR METALS SHALL BE ISOLATED FROM EACH

OTHER EVEN IF NOT SPECIFICALLY IDENTIFIED IN THE

CONTRACT DOCUMENTS.

13. ALL CODE-REQUIRED LABELS SUCH AS "UL", “FACTORY

MUTUAL”, OR ANY EQUIPMENT IDENTIFICATION, PERFORMANCE

RATING, NAME, OR NOMENCLATURE PLATES SHALL REMAIN

READABLE AND NOT PAINTED OR COVERED BY OTHER

CONSTRUCTION.

14. STRUCTURAL INFORMATION ON ARCHITECTURAL DRAWINGS IS

FOR REFERENCE ONLY. STRUCTURAL INFORMATION ON

STRUCTURAL DRAWINGS AND SPECIFICATIONS SHALL

GOVERN.

15. ARCHITECTURAL DIMENSIONS AND DESIGN INTENT ARE

INDICATED ON ARCHITECTURAL DRAWINGS. IF THE

INSTALLATION OF EQUIPMENT FROM OTHER TRADES

INTERFERES WITH COMPLIANCE OF THE DESIGN INTENT,

NOTIFY THE ARCHITECT BEFORE PROCEEDING.

16. DO NOT SCALE DRAWINGS; DIMENSIONS GOVERN LOCATION

OF BUILDING ELEMENTS. IF DIMENSIONS ARE NOT AVAILABLE,

CONTACT THE ARCHITECT.

17. WHEN DIMENSIONS ON SMALL SCALE DRAWINGS CONFLICT

WITH THOSE ON LARGE SCALE DRAWINGS, THE LARGE SCALE

DRAWINGS GOVERN.

18. OWNER TO REMOVE FURNISHINGS AND STORED ITEMS AS

REQUIRED FOR NEW CONSTRUCTION.

PROJECT GENERAL INFORMATION

VIEW NUMBER

GENERAL SYMBOLS LEGEND

A1 VIEW NAME

100'-0"

12" = 1'-0" 12"

VIEW SCALE

NORTH ARROW

VIEW NUMBER

SHEET NUMBER

BUILDING SECTION MARK

VIEW NUMBER

SHEET NUMBER

WALL SECTION MARK

VIEW NUMBER

SHEET NUMBER

DETAIL SECTION MARK

VIEW NUMBER

SHEET NUMBER

EXTERIOR ELEVATION MARK

VIEW NUMBER

SHEET NUMBER

INTERIOR ELEVATION MARK

ENLARGED DETAIL MARK

VIEW NUMBER

SHEET NUMBER

KEYNOTE VALUEA00

REVISION NUMBER

REVISION TYPE

EXISTING GRID ID MARK

NEW GRID ID MARK

IDENTIFIED LEVEL NAME

ELEVATION MARK

SPOT ELEVATION MARK

ROOM NAME

101 ROOM NUMBER

A4/A104

VIEW NUMBER / SHEET NUMBER OF

CONTINUING VIEW

MATCHLINE

A1 A101

A1 A101

A1 A101

A1 A101

A1 A101

A1

A1A1

A1

A100

A1 A101

RFI

FIRST FLOOR

100'-0"

N

A P

P R

O V

E D

B Y

D R

A W

N B

Y

IS

S

U E

D F

O R

IS

S

U E

D A

T E

P R

O

JE

C T

N U

M B

E R

F

IE

LD

B

O O

K

0.

8.

S H

IV

E

-H A

T T

E R

Y .C

O M

BA D E

FC G

H

BA D E FC G H

Autodesk Revit 2024Autodesk Revit 2024

6/

/2

6:

:2

P

M

A ut od es k D oc s:

//2

IA

N

G

C lin to n

M V

S B

Im p/

-A

-R

-I A

N G

C lin to n M

V S

B Im p.

rv t

P R

O

JE

C T

G E

N E

R A

L

IN

F O

R M

A T

IO

N

B

ID

A pp ro ve r

A ut ho r

/1

3/

G001

IO

W

A A

R M

Y N

A T

IO

N

A L

G U

A R

D C

L

IN

T O

N M

V S

B

A

LT

E R

A T

IO

N

Io w a A rm y

N a tio na l G ua rd

3t h

A V

E N

U E

N O

R T

H

C

LI

N T

O N

IO

W A

/2

5/

EXISTING WALL PARTITIONS

DEMOLITION PLAN SYMBOLS LEGEND

TEMPORARY WALL PARTITIONS

DEMOLISHED WALL PARTITIONS

EXISTING DOOR

DEMOLISHED DOOR

1. FIELD VERIFY EXISTING CONDITIONS PRIOR TO START OF

DEMOLITION WORK. NOTIFY ARCHITECT IN WRITING OF

DISCREPANCIES BETWEEN WORK SHOWN IN THE DRAWINGS

AND FIELD CONDITIONS ENCOUNTERED.

2. TO PROTECT OWNER AND CONTRACTOR, PHOTOGRAPHICALLY

DOCUMENT EXISTING CONDITIONS TO REMAIN, PRIOR TO

START OF DEMOLITION AND CONSTRUCTION ACTIVITIES. COPY

ARCHITECT AND OWNER ON PHOTOGRAPHIC

DOCUMENTATION.

3. OPEN FLAME EQUIPMENT IS NOT PERMITTED FOR REMOVAL OF

EXISTING WORK WITHOUT SPECIFIC WRITTEN PERMISSION

FROM THE OWNER.

4. COORDINATE WITH OWNER ANY ITEMS TO BE SALVAGED.

5. OWNER WILL REMOVE ALL NON-FIXED FURNISHINGS AND

EQUIPMENT FROM THE CONSTRUCTION AREA PRIOR TO START

OF CONSTRUCTION UNLESS NOTED OTHERWISE.

6. MAINTAIN BUILDING IN A WEATHER-TIGHT CONDITION. DO NOT

PERFORM WORK ON EXTERIOR OPENINGS THAT CANNOT BE

COMPLETED OR MADE WEATHER-TIGHT WHEN INCLEMENT

WEATHER IS POSSIBLE.

7. COORDINATE WITH OTHER TRADES CUTTING AND PATCHING

REQUIRED FOR DEMOLITION OR NEW CONSTRUCTION.

8. ANY DEMOLITION OR REMOVAL INDICATED IS SHOWN IN

GENERAL TO PROVIDE THE EXTENT OF DEMOLITION AND IS

NOT TO BE CONSIDERED AS A RECORD DRAWING OF EXISTING

CONDITIONS. THE CONTRACTOR IS RESPONSIBLE FOR IN FIELD

VERIFICATION AND COORDINATION WITH THE ARCHITECT

PRIOR TO COMMENCING WITH STATED WORK.

9. ALL CONSTRUCTION TO REMAIN WHICH IS AFFECTED BY

DEMOLITION SHALL BE PATCHED, BE PROPERLY ALIGNED AND

FINISHED SO AS TO LEAVE NO EVIDENCE OF PATCHING OR

REPAIR. REPAIR OR REPLACE ANY EXISTING CONSTRUCTION,

MATERIALS, OR EQUIPMENT DAMAGED DURING DEMOLITION TO

LIKE NEW CONDITION.

10. THE CONTRACTOR IS TO RETURN SALVAGEABLE MATERIALS,

INCLUDING BUT NOT LIMITED TO DOORS, FRAMES, HARDWARE,

MARBLE, EQUIPMENT, AND LIGHTING FIXTURES TO THE OWNER

AND STOCKPILE THEM IN AN APPROVED CONSTRUCTION AREA.

DISPOSE OF THESE MATERIALS AFTER OWNER'S REVIEW AND

APPROVAL.

11. CONTRACTOR IS RESPONSIBLE FOR PROTECTION OF ALL

FINISHES (TO REMAIN) IN THE PROJECT AREA. COORDINATE

WITH ARCHITECT AND OWNER PRIOR TO DEMOLITION.

12. CONTRACTOR SHALL ENSURE THAT DUST AND DEBRIS ARE

PREVENTED FROM ENTERING THE EXISTING HVAC SYSTEM

AND ADJOINING SPACES WITH TEMPORARY BARRIERS AS

REQUIRED PER THE BUILDING.

13. INDICATION OF NEW MATERIALS SHALL INFER ALL REMOVAL OR

DEMOLITION AND PATCHING REQUIRED OF EXISTING

MATERIALS AND SUBSTRATES FOR PROPER ALIGNMENT.

MATCH EXISTING FINISHES.

14. ALL NEW AND EXISTING PENETRATIONS IN EXISTING WALLS,

FLOORS AND CEILING DECKS SHALL BE THE RESPONSIBILITY

OF THE PRIME CONTRACTOR AND SHALL RECEIVE UL AND

FACILITY APPROVED FIRE SEALANT MATERIALS TO MATCH

RATING REQUIREMENT OF AREA BEING PENETRATED.

ARCHITECTURAL DEMOLITION NOTES

A B C D E F

7,513 SF

MVSB 1

AD.01

AD.01

A01.01

E3 A101

AD.02 AD.02 AD.02 AD.02 AD.02

AD.03

A01.17

A P

P R

O V

E D

B Y

D R

A W

N B

Y

IS

S

U E

D F

O R

IS

S

U E

D A

T E

P R

O

JE

C T

N U

M B

E R

F

IE

LD

B

O O

K

0.

8.

S H

IV

E

-H A

T T

E R

Y .C

O M

BA D E

FC G

H

BA D E FC G H

Autodesk Revit 2024Autodesk Revit 2024

6/

/2

6:

:2

P

M

A ut od es k D oc s:

//2

IA

N

G

C lin to n

M V

S B

Im p/

-A

-R

-I A

N G

C lin to n M

V S

B Im p.

rv t

D E

M O

LI

T

IO

N

P

LA

N S

B

ID

C

LM

R C

B

/1

3/

AD01

IO

W

A A

R M

Y N

A T

IO

N

A L

G U

A R

D C

L

IN

T O

N M

V S

B

A

LT

E R

A T

IO

N

Io w a A rm y

N a tio na l G ua rd

3t h

A V

E N

U E

N O

R T

H

C

LI

N T

O N

IO

W A

NORTH

01/8" = 1'-0"D6 FIRST FLOOR DEMOLITION PLAN

12'

KEYNOTES

KEY NOTE

A01.01 EXISTING CAGING TO REMAIN IN PLACE

A01.17 EXISTING CONTROLLED HUMIDITY PRESERVATION

EQUIPMENT TO REMAIN

AD.01 REMOVE DOOR PANEL, DOOR FRAME TO REMAIN,

SALVAGE EXISTING DOOR HARDWARE. HARDWARE TO

BE REINSTALLED WITH NEW DOOR PANEL.

AD.02 REMOVE EXISTING OVERHEAD DOOR SYSTEM

INCLUDING DOOR PANEL AND TRACKS. EXISTING

STRUCTURAL SYSTEM SUPPORTING OVERHEAD DOOR

TO REMAIN.

AD.03 REMOVE FIRE EXTINGUISHER, REINSTALL ON UNISTRUT

SUPPORT

/2

5/

126'-4"

'-0

A B C D E F

7,513 SF

MVSB 1

100 101 102 103

A07.02

A07.03

A08.01

A08.01

A07.01

A07.01

A01.01

E3 A101

A01.01

A07.06

A01.04 A01.04 A01.04 A01.04 A01.04

A01.04

A01.09 A01.09

A08.02

A08.02

A10.01

A01.17

A20

A3

A200F3

A09.02

A01.06

A200C3

A200 C6

A201

C2

A201

E2

A201

C2

A201 A4

A200 G6

A200 E6

DOOR MARK

FLOOR PLAN SYMBOLS LEGEND

CW GLAZED OPENING MARK

1. WHERE STRUCTURAL ELEMENTS INTERFERE WITH FIRE-RATED

PARTITIONS, FRAME TOP OF WALL AROUND STRUCTURAL

ELEMENT.

2. REFER TO DRAWINGS OF ALL TRADES FOR ADDITIONAL

INFORMATION REGARDING ITEMS PENETRATING FLOORS,

WALLS, AND CEILINGS.

3. ALL NEW PARTITIONS ARE DIMENSIONED TO FACE OF STUD,

MASONRY, OR CONCRETE COMPONENT UNLESS NOTED

OTHERWISE. DIMENSIONS TO EXISTING ELEMENTS ARE TO

EXPOSED FACE.

4. ALL ANGLED PARTITIONS SHOWN SHALL BE AT A 45° ANGLE

UNLESS NOTED OTHERWISE.

5. PHOTOS PROVIDED ON SHEETS A200, A201, AND A202 FOR

GENERAL CONDITIONS AND ADDITIONAL OBSTRUCTIONS

INSULATION AND VAPOR BARRIER SYSTEM WILL NEED TO

ACCOUNT FOR.

FLOOR PLAN NOTES

A B C D E F

MVSB 1

A07.04

E3 A101

TYPA01.02

A01.13

A01.12A01.12

A01.12

A01.12A01.12

A201F6

A01.12 A01.12 A01.12 A01.12 A01.12

A07.07 A07.07 A07.07 A07.07 A07.07

100' - 0"

FIRST FLOOR

117' - 0"

B/O ROOF, VIF

RIGID INSULATION WITH 20 GA PREFINISHED

GALV METAL CLOSURE PANEL, WRAP

INSULATION OVER STEM WALL AS NEEDED

TO PROVIDE CONTINUOUS INSULATION

METAL BUILDING INSULATION SYSTEM,

PROVIDE CONTINUOUS INSULATION AND AIR

BARRIER AROUND PERIMETER OF EXISTING

BUILDING, SEE SPECIFICATION. INSTALL PER

MANUFACTURER INSTRUCTIONS.

METAL LINER PANEL, UP TO 8'-0" AFF MIN,

FASTEN TO EXISTING BUILDING STRUCTURE

EXISTING BUILDING STRUCTURE

BEYOND, FIELD VERIFY LOCATION AND

SPACING

EXISTING CONCRETE STEM WALL

EXISTING CONCRETE FLOOR

EXISTING BUILDING STRUCTURE, FIELD

VERIFY LOCATION AND SPACING

EXISTING BUILDING STRUCTURE, FIELD

VERIFY LOCATION AND SPACING

'-0

M

IN

METAL BUILDING ROOF INSULATION SYSTEM

WITH CONTINUOUS PERFORATED MEMBRANE

OVER EXISTING ROOF SYSTEM. PROVIDE

ACCOMMODATIONS TO PREVENT MOISTURE

COLLECTION BETWEEN THE EXISTING AND

NEW SYSTEMS, SEE SPECIFICATION. INSTALL

PER MANUFACTURER INSTRUCTIONS.

EXISTING METAL BUILDING ROOF

INSULATION SYSTEM TO REMAIN

METAL STUD RUNNER TRACK

PRIME RIGID INSULATION AS NECESSARY TO

PROVIDE SURFACE FOR METAL BUILDING

INSULATION SYSTEM TO TIE INTO. PROVIDE

CONTINUOUS VAPOR BARRIER.

F

P E

R S

C H

E D

U

LE

SCHEDULE

PER

OHSF

P E

R S

C H

E D

U

LE

PER SCHEDULE

VISION LITE, LOCATED

NEAR PULL CHAIN

2'-0"

CONT WOOD BLOCKING PER MFR

WEATHER STRIP W/ COLOR

MATCHING FASTENERS

EXISTING METAL CLOSURE

TO REMAIN

DOOR TRACK

OVERHEAD SECTIONAL DOOR;

SEE DOOR SCHEDULE

METAL BUILDING INSULATION SYSTEM

METAL LINER PANEL, UP TO 8'-0" AFF

EXISTING BUILDING STRUCTURE, FIELD

VERIFY LOCATION AND SPACING

EXISTING METAL BUILDING CLADDING

VIF

VIF

OVERHEAD SECTIONAL DOOR

FRAME

WEATHER STRIP W/ COLOR

MATCHING FASTENERS

2x WOOD BLOCKING AS

REQUIRED

20 GA PREFINISHED GALV

METAL CLOSURE FLASHING

W/DRIP EDGE

/2

METAL BUILDING INSULATION SYSTEM

METAL LINER PANEL, UP TO 8'-0" AFF

EXISTING BUILDING STRUCTURE, FIELD

VERIFY LOCATION AND SPACING

EXISTING METAL BUILDING CLADDING

FILL EXISTING STRUCTURAL FRAMING

WITH INSULATION

A P

P R

O V

E D

B Y

D R

A W

N B

Y

IS

S

U E

D F

O R

IS

S

U E

D A

T E

P R

O

JE

C T

N U

M B

E R

F

IE

LD

B

O O

K

0.

8.

S H

IV

E

-H A

T T

E R

Y .C

O M

BA D E

FC G

H

BA D E FC G H

Autodesk Revit 2024Autodesk Revit 2024

6/

/2

3:

:1

P

M

A ut od es k D oc s:

//2

IA

N

G

C lin to n

M V

S B

Im p/

-A

-R

-I A

N G

C lin to n M

V S

B Im p.

rv t

F

IR

S T

F

LO

O R

P

LA

N B

ID

C

LM

R C

B

/1

3/

A101

IO

W

A A

R M

Y N

A T

IO

N

A L

G U

A R

D C

L

IN

T O

N M

V S

B

A

LT

E R

A T

IO

N

Io w a A rm y

N a tio na l G ua rd

3t h

A V

E N

U E

N O

R T

H

C

LI

N T

O N

IO

W A

01/4" = 1'-0"

DOOR PANEL ELEVATIONS

6'

NORTH

01/8" = 1'-0"A6 FIRST FLOOR PLAN

12'

KEYNOTES

KEY NOTE

A01.01 EXISTING CAGING TO REMAIN IN PLACE

A01.02 EXISTING BUILDING STRUCTURE, FIELD VERIFY

LOCATION AND SPACING

A01.04 EXISTING CAGING EXTENDS ABOVE CONCRETE STEM

WALL, SEE PHOTOS OF TYPICAL CAGING EXTENSIONS

ON A202

A01.06 BOX AND CONDUIT TO REMAIN IN PLACE

A01.09 EXISTING CAGING CEILING TO REMAIN OVER AREAS

SECURED BY CAGING WALLS

A01.12 ALL LIGHT FIXTURES AND ASSOCIATED CONDUIT TO

REMAIN, TYPICAL

A01.13 AUDIO EQUIPMENT TO REMAIN

A01.17 EXISTING CONTROLLED HUMIDITY PRESERVATION

EQUIPMENT TO REMAIN

A07.01 FILL EXISTING DOOR FRAME WITH INSULATION

A07.02 METAL BUILDING INSULATION SYSTEM, PROVIDE

CONTINUOUS INSULATION AND AIR BARRIER AROUND

PERIMETER OF EXISTING BUILDING, SEE

SPECIFICATION. INSTALL PER MANUFACTURER

INSTRUCTIONS.

A07.03 RIGID INSULATION WRAP AROUND STEM WALL WITH 20

GA PREFINISHED GALV METAL CLOSURE PANEL

A07.04 METAL BUILDING ROOF INSULATION SYSTEM WITH

CONTINUOUS PERFORATED MEMBRANE OVER

EXISTING ROOF SYSTEM. PROVIDE ACCOMMODATIONS

TO PREVENT MOISTURE COLLECTION BETWEEN THE

EXISTING AND NEW SYSTEMS, SEE SPECIFICATION.

INSTALL PER MANUFACTURER INSTRUCTIONS.

A07.06 METAL LINER PANEL, UP TO 8'-0" MIN, FASTEN TO

EXITING BUILDING STRUCTURE

A07.07 FILL EXISTING STRUCTURAL FRAMING AT OVERHEAD

DOORS WITH INSULATION

A08.01 NEW INSULATED DOOR PANEL, SEE SPECIFICATIONS

FOR NEW HARDWARE REQUIREMENTS.

A08.02 EXISTING DOOR FRAME TO REMAIN, PAINT

A09.02 PROVIDE NEW UNISTRUT SUPPORTS FOR ELECTRICAL

EQUIPMENT, MOUNT NEW SUPPORTS TO FRONT OF

STEEL SYSTEM, ALIGN LOCATION WITH EXISTING

UNISTRUT BEHIND. SEE ELECTRICAL DRAWINGS FOR

TEMPORARY SUPPORT OF CABLE BOARD DURING

CONSTRUCTION

A10.01 REINSTALL EXISTING FIRE EXTINGUISHER, PROVIDE

UNISTRUT FOR REMOUNTING FIRE EXTINGUISHER

NORTH

01/8" = 1'-0"A3 FIRST FLOOR REFLECTED CEILING PLAN

12'

DOOR AND FRAME SCHEDULE

MARK ROOM NAME

OPENING SIZE DOOR FRAME DETAILS

HARDWARE RATING REMARKSWIDTH HEIGHT THICKNESS TYPE MATERIAL GLAZING MTRL-TYPE FINISH HEAD JAMB SILL 100 16' - 4" 16' - 0" 1" OHSF -- -- OHS -- G5/A101 G6/A101 SEE SPEC FIELD VERIFY EXISTING DOOR

OPENING SIZE

101 16' - 4" 16' - 0" 1" OHSF -- -- OHS -- G5/A101 G6/A101 SEE SPEC -- FIELD VERIFY EXISTING DOOR

OPENING SIZE

102 16' - 4" 16' - 0" 1" OHSF -- -- OHS -- G5/A101 G6/A101 SEE SPEC -- FIELD VERIFY EXISTING DOOR

OPENING SIZE

103 16' - 4" 16' - 0" 1" OHSF -- -- OHS -- G5/A101 G6/A101 SEE SPEC -- FIELD VERIFY EXISTING DOOR

OPENING SIZE

104 16' - 4" 16' - 0" 1" OHSF -- -- OHS -- G5/A101 G6/A101 SEE SPEC -- FIELD VERIFY EXISTING DOOR

OPENING SIZE

105 MVSB 1 3' - 0" 7' - 0" 1 3/4" F HM -- EXISTING EXISTING -- -- -- 01 -- FIELD VERIFY EXISTING DOOR

OPENING SIZE

106 MVSB 1 3' - 0" 7' - 0" 1 3/4" F HM -- EXISTING EXISTING -- -- -- 01 -- FIELD VERIFY EXISTING DOOR

OPENING SIZE

01/2" = 1'-0"E3 WALL SECTION

3'

MVSB 1

MVSB 1

MVSB 1

MVSB 1

MVSB 1

01 1/2" = 1'-0"G6 JAMB - OHS

1'

01 1/2" = 1'-0"G5 HEAD - OHS

1'

DOOR HARDWARE GROUPS

GROUP 01

SINGLE SWING DOOR

3 EA. HEAVY DUTY HINGES

1 EA SURFACE MOUNTED CLOSER

1 EA MORTISE LOCKSET

1 SET WEATHERSTRIPPING

1 SET GASKETING

/2

5/

PROVIDE NEW

UNISTRUT SUPPORTS

FOR ELECTRICAL

EQUIPMENT, MOUNT

NEW SUPPORTS TO

FRONT OF STEEL

SYSTEM, ALIGN

LOCATION WITH

EXISTING UNISTRUT

BEHIND. SEE

ELECTRICAL DRAWINGS

FOR TEMPORARY

SUPPORT OF CABLE

BOARD DURING

CONSTRUCTION

OWNER TO REMOVE

FURNISHINGS AS NEEDED FOR

NEW CONSTRUCTION

OWNER TO REMOVE STOCK

MATERIALS

UNISTRUT TO REMAIN IN

PLACE, SEE ELECTRICAL

DRAWINGS FOR EQUIPMENT

COORDINATION

EXISTING CONTROLLED HUMIDITY

PRESERVATION EQUIPMENT TO

REMAIN.

BOX AND CONDUIT TO REMAIN

IN PLACE

CONDUIT TO REMAINCONDUIT TO REMAIN

CONDUIT TO REMAIN

REMOVE FIRE EXTINGUISHER,

REINSTALL ON UNISTRUT

SUPPORT

INSTALL NEW UNISTRUT

SUPPORT, MOUNT NEW

SUPPORT TO FACE OF STEEL

SYSTEM

CAGE EXTENSIONS TO

REMAIN IN PLACE AT BOTH

CAGE WALLS AND CAGE

CEILING

CAGE EXTENSIONS TO

REMAIN IN PLACE AT BOTH

CAGE WALLS AND CAGE

CEILING

1. PHOTOS PROVIDED FOR REFERENCE, FIELD VERIFY EXISTING

CONDITIONS.

2. ALL CAGING, CAGE EXTENSIONS, AND CAGE CEILINGS TO

REMAIN.

3. OWNER TO REMOVE FURNISHINGS AND STORED ITEMS AS

REQUIRED FOR NEW CONSTRUCTION.

4. PHOTOS DEPICT TYPICAL CONDITIONS OF OBSTRUCTIONS TO

THE NEW INSULATION SYSTEM. NOT ALL INSTANCES OF

OBSTRUCTIONS ARE DEPICTED, FIELD VERIFY EXISTING

CONDITIONS.

5. CONTRACTORS ARE SUGGESTED TO REVIEW EXISTING

CONDITIONS PRIOR TO BIDDING. CONTACT OWNER’S

REPRESENTATIVE FOR ACCESS TO FACILITY.”

GENERAL NOTES

A P

P R

O V

E D

B Y

D R

A W

N B

Y

IS

S

U E

D F

O R

IS

S

U E

D A

T E

P R

O

JE

C T

N U

M B

E R

F

IE

LD

B

O O

K

0.

8.

S H

IV

E

-H A

T T

E R

Y .C

O M

BA D E

FC G

H

BA D E FC G H

Autodesk Revit 2024Autodesk Revit 2024

6/

/2

3:

:1

P

M

A ut od es k D oc s:

//2

IA

N

G

C lin to n

M V

S B

Im p/

-A

-R

-I A

N G

C lin to n M

V S

B Im p.

rv t

P H

O T

O S

G

E N

E R

A L

C O

N D

IT

IO

N S

B

ID

C

LM

R C

B

/1

3/

A200

IO

W

A A

R M

Y N

A T

IO

N

A L

G U

A R

D C

L

IN

T O

N M

V S

B

A

LT

E R

A T

IO

N

Io w a A rm y

N a tio na l G ua rd

3t h

A V

E N

U E

N O

R T

H

C

LI

N T

O N

IO

W A

012" = 1'-0"F3 WEST WALL ELEVATION

1.5"012" = 1'-0"E3 WEST ELEVATION

1.5"012" = 1'-0"C3 WEST ELEVATION

1.5"012" = 1'-0"A3 WEST ELEVATION

1.5"

012" = 1'-0"A4 NORTH WALL ELEVATION

1.5" 012" = 1'-0"E4 TYPICAL EXISTING OVERHEAD DOOR JAMB

1.5"012" = 1'-0"C4 TYPICAL EXISTING OVERHEAD DOOR JAMB

1.5" 012" = 1'-0"G4 TYPICAL CAGE POST FLOOR MOUNT

1.5"

012" = 1'-0"C6 EAST WALL ELEVATION

1.5" 012" = 1'-0"E6 EAST WALL ELEVATION - EXISTING COLUMN CONDITION

1.5" 012" = 1'-0"G6 EAST WALL ELEVATION - EXISTING COLUMN CONDITION

1.5"012" = 1'-0"A6 EAST WALL ELEVATION - TYP CAGE END AT WALL

1.5"

/2

5/

EXISTING CAGING TO REMAIN

IN PLACE

ELECTRICAL EQUIPMENT AND

CONDUIT TO REMAIN

OWNER TO REMOVE

FURNISHINGS AS NEEDED FOR

NEW CONSTRUCTION

EXISTING CAGING AND CAGE

CEILING TO REMAIN

EXISTING CAGING AND CAGE

CEILING TO REMAIN

THRESHOLD TO REMAIN

ELECTRICAL EQUIPMENT AND

CONDUIT TO REMAIN

EXISTING DOOR FRAME TO

REMAIN, PAINT

CONDUIT AND SWITCHES TO

REMAIN

ALL LIGHT FIXTURES AND

ASSOCIATED CONDUIT TO

REMAIN, TYPICAL

AUDIO EQUIPMENT TO REMAIN

1. PHOTOS PROVIDED FOR REFERENCE, FIELD VERIFY EXISTING

CONDITIONS.

2. ALL CAGING, CAGE EXTENSIONS, AND CAGE CEILINGS TO

REMAIN.

3. OWNER TO REMOVE FURNISHINGS AND STORED ITEMS AS

REQUIRED FOR NEW CONSTRUCTION.

4. PHOTOS DEPICT TYPICAL CONDITIONS OF OBSTRUCTIONS TO

THE NEW INSULATION SYSTEM. NOT ALL INSTANCES OF

OBSTRUCTIONS ARE DEPICTED, FIELD VERIFY EXISTING

CONDITIONS.

5. CONTRACTORS ARE SUGGESTED TO REVIEW EXISTING

CONDITIONS PRIOR TO BIDDING. CONTACT OWNER’S

REPRESENTATIVE FOR ACCESS TO FACILITY.”

GENERAL NOTES

A P

P R

O V

E D

B Y

D R

A W

N B

Y

IS

S

U E

D F

O R

IS

S

U E

D A

T E

P R

O

JE

C T

N U

M B

E R

F

IE

LD

B

O O

K

0.

8.

S H

IV

E

-H A

T T

E R

Y .C

O M

BA D E

FC G

H

BA D E FC G H

Autodesk Revit 2024Autodesk Revit 2024

6/

/2

3:

:3

P

M

A ut od es k D oc s:

//2

IA

N

G

C lin to n

M V

S B

Im p/

-A

-R

-I A

N G

C lin to n M

V S

B Im p.

rv t

P H

O T

O S

G

E N

E R

A L

C O

N D

IT

IO

N S

B

ID

C

LM

R C

B

/1

3/

A201

IO

W

A A

R M

Y N

A T

IO

N

A L

G U

A R

D C

L

IN

T O

N M

V S

B

A

LT

E R

A T

IO

N

Io w a A rm y

N a tio na l G ua rd

3t h

A V

E N

U E

N O

R T

H

C

LI

N T

O N

IO

W A

012" = 1'-0"A4 SOUTH WALL ELEVATION

1.5" 012" = 1'-0"C4 SOUTH WALL ELEVATION

1.5"

012" = 1'-0"C2 SOUTH WALL ELEVATION - TYP CAGE ENCLOSURE

1.5" 012" = 1'-0"E2 SOUTH WALL ELEVATION - TYP CAGE ENCLOSURE

1.5"

012" = 1'-0"E4 SOUTH WALL ELEVATION

1.5" 012" = 1'-0"F4 SOUTH WALL ELEVATION

1.5"

012" = 1'-0"A2 SOUTH WALL ELEVATION - TYP COLUMN BASE

1.5"

012" = 1'-0"F6 CEILIING VIEW

1.5"012" = 1'-0"C6 CEILING VIEW

1.5"

/2

5/

EXISTING CAGING STEEL TO

REMAIN

1. PHOTOS PROVIDED FOR REFERENCE, FIELD VERIFY EXISTING

CONDITIONS.

2. ALL CAGING, CAGE EXTENSIONS, AND CAGE CEILINGS TO

REMAIN.

3. OWNER TO REMOVE FURNISHINGS AND STORED ITEMS AS

REQUIRED FOR NEW CONSTRUCTION.

4. PHOTOS DEPICT TYPICAL CONDITIONS OF OBSTRUCTIONS TO

THE NEW INSULATION SYSTEM. NOT ALL INSTANCES OF

OBSTRUCTIONS ARE DEPICTED, FIELD VERIFY EXISTING

CONDITIONS.

5. CONTRACTORS ARE SUGGESTED TO REVIEW EXISTING

CONDITIONS PRIOR TO BIDDING. CONTACT OWNER’S

REPRESENTATIVE FOR ACCESS TO FACILITY.”

GENERAL NOTES

012" = 1'-0"D6 SOUTH WALL ELEVATION - TYP CAGE EXTENTION BASE

1.5" 012" = 1'-0"F6 SOUTH WALL ELEVATION - CAGE STEEL

1.5"

012" = 1'-0"D5 SOUTH WALL ELEVATION - TYP CAGE EXTENSION

1.5"012" = 1'-0"B5 SOUTH WALL ELEVATION - TYP CAGE EXTENSIONS

1.5"

012" = 1'-0"B6 SOUTH WALL ELEVATION - CAGE CEILNIG

1.5"

A P

P R

O V

E D

B Y

D R

A W

N B

Y

IS

S

U E

D F

O R

IS

S

U E

D A

T E

P R

O

JE

C T

N U

M B

E R

F

IE

LD

B

O O

K

0.

8.

S H

IV

E

-H A

T T

E R

Y .C

O M

BA D E

FC G

H

BA D E FC G H

Autodesk Revit 2024Autodesk Revit 2024

6/

/2

3:

:4

P

M

A ut od es k D oc s:

//2

IA

N

G

C lin to n

M V

S B

Im p/

-A

-R

-I A

N G

C lin to n M

V S

B Im p.

rv t

P H

O T

O S

E

X

IS

S T

IN

G

C A

G

IN

G B

ID

C

LM

R C

B

/1

3/

A202

IO

W

A A

R M

Y N

A T

IO

N

A L

G U

A R

D C

L

IN

T O

N M

V S

B

A

LT

E R

A T

IO

N

Io w a A rm y

N a tio na l G ua rd

3t h

A V

E N

U E

N O

R T

H

C

LI

N T

O N

IO

W A

012" = 1'-0"B2 SOUTH WALL ELEVATION - CAGE CEILING AT COLUMN

1.5" 012" = 1'-0"D2 SOUTH WALL ELEVATION - CAGE EXTENSION

1.5"

012" = 1'-0"F5 SOUTH WALL ELEVATION - TYP CAGE EXTENSION

1.5"

012" = 1'-0"F2 SOUTH WALL ELEVATION - CAGE EXTENSION

1.5"

/2

5/

1. PIPING IS SHOWN IN SCHEMATIC FORM, ROUTE AS REQUIRED

FOR CLEARANCE. VERIFY ROUTING AND CLEARANCES AND

COORDINATE WITH OTHER TRADES PRIOR TO FABRICATION.

THE CONTRACTOR SHALL PROVIDE COMPLETE FULLY

FUNCTIONAL SYSTEMS.

2. BREAK CONNECTIONS REQUIRED AT ALL MAJOR EQUIPMENT

AND PIPING ITEMS THAT REQUIRE REMOVAL FOR

MAINTENANCE.

3. PIPE REDUCTIONS ON HORIZONTAL PIPING GOING FROM

LARGER TO SMALLER SHALL BE MADE WITH ECCENTRIC

REDUCERS: TOP FLAT FOR LIQUID SYSTEMS, CONCENTRIC

REDUCERS MAY BE USED FOR FLOW GOING FROM SMALL TO

LARGER SIZE PIPE.

4. NEW FLOOR/WALL/CEILING PENETRATIONS REQUIRED FOR

MECHANICAL PIPING INSTALLATION SHALL BE CLEANLY BORED

AT RIGHT ANGLES. AS NEW PIPING IS INSTALLED, NEW PIPING

PENETRATIONS SHALL BE NEATLY CAULKED TO FILL VOID.

WALL PENETRATIONS SHALL BE FINISHED WITH

ESCUTCHEONS.

5. ALL NEW EQUIPMENT AND ACCESSORIES SHALL BE INSTALLED

SO AS TO BE EASILY ACCESSIBLE.

6. CONTRACTOR SHALL PATCH/REPAIR ALL UNUSED OPENINGS

AND MODIFIED FINISH SURFACES. PATCHING SHALL MATCH

MATERIALS, FINISH AND TEXTURE OF ADJACENT SURFACES.

7. ALL WORK WITHIN THE CONTRACT DOCUMENTS, WHICH

INCLUDE THIS DRAWING, SHALL BE COMPLETED IN A SAFE

WORKMANLIKE MANNER AND IN ACCORDANCE WITH ALL

APPLICABLE STATE, LOCAL AND NATIONAL CODES,

REGULATIONS AND ORDINANCES. IF ANY CONFLICTS ARISE

BETWEEN THE CONTRACT DOCUMENTS AND THE APPLICABLE

CODES, REGULATIONS OR ORDINANCE, THE CONTRACTOR

SHALL BE RESPONSIBLE TO HAVE ALL WORK CONFORM TO

THE STRICTER OF SAID REQUIREMENTS.

8. THE CONTRACTOR IS RESPONSIBLE FOR OBTAINING ALL

PERMITS AND INSPECTIONS AS REQUIRED FOR ELECTRICAL,

AND MECHANICAL INSTALLATIONS. IT SHALL BE THE

CONTRACTOR'S RESPONSIBILITY TO PROVIDE BOTH A

COMPLETE AND COMPLIANT INSTALLATION AS MAY BE

DETERMINED BY THE AUTHORITY(S) HAVING JURISDICTION.

9. CONTRACTOR SHALL NOT PROCURE OR FABRICATE ANY

PIPING, DUCTWORK OR OTHER EQUIPMENT WITHOUT FIRST

VERIFYING ALL DIMENSIONS AND CONDITIONS WHETHER

CURRENTLY EXISTING OR NOT. THE CONTRACTOR SHALL BE

RESPONSIBLE FOR ALL WORK, INCLUDING ANY REQUIRED

REWORK.

10. MAINTAIN ALL MANUFACTURER RECOMMENDED EQUIPMENT

SERVICE AND SAFETY CLEARANCES. DO NOT LOCATE ANY

EQUIPMENT OR RUN MATERIALS ABOVE ANY ELECTRICAL

PANELS OR SWITCHGEAR. MAINTAIN ALL NFPA/NEC CODE

REQUIRED CLEARANCES.

11. EACH CONTRACTOR SHALL BE RESPONSIBLE FOR

COORDINATING, SCHEDULING AND SEQUENCING OF THEIR

WORK WITH ALL OTHER TRADES. PROVIDE OFFSETS,

EASEMENTS, OR RELOCATE TO AVOID CONFLICTS WITH WORK

OF OTHER TRADES. FURNISH SUFFICIENT RESOURCES TO

MEET ALL PROJECT MILESTONES AND DEADLINES.

12. CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAINING THE

WATERTIGHT AND WEATHER-PROOF INTEGRITY OF ROOFS,

WALLS AND FLOORS DURING CONSTRUCTION. EACH TRADE

SHALL LOCATE/DIMENSION/COORDINATE THEIR ROOF, FLOOR

AND WALL OPENINGS WITH THE GENERAL CONTRACTOR (GC)

OR CONSTRUCTION MANAGER.

13. PROTECT NEW WORK FROM DAMAGE OR CONTAMINATION.

PROVIDE TEMPORARY PROTECTIVE CAPPING OR TAPED

POLYETHYLENE ENCLOSURES OVER OPEN DUCTWORK AND

PIPING ENDS AND EQUIPMENT. CONTRACTOR SHALL BE

RESPONSIBLE FOR CLEANING MECHANICAL SYSTEMS PRIOR

TO PLACING THEM IN SERVICE.

14. IN A NEAT AND WORKMANLIKE MANNER: PATCH ANY

REMAINING OPENINGS AND FILL EXCESSIVE GAPS; REWORK

AND REFINISH TO MATCH ADJACENT STRUCTURES; FLASH

AND SEAL ALL MECHANICAL AND ELECTRICAL PENETRATIONS

THRU WALLS, CEILINGS, AND FLOORS WITH METAL

FRAMEWORK OR ESCUTCHEONS. ALL OPENINGS SHALL BE

PROPERLY SEALED SO AS TO MEET FIRE RATING NEEDS.

MECHANICAL PIPING

PRESSURE REDUCING VALVE

BALL VALVE

MOTORIZED CONTROLVALVE

ELBOW UP

ELBOW DOWN

PIPE OFFSET UP

PIPE OFFSET DOWN

PIPE CAP

PIPE TEE TURNED UP

PIPE TEE TURNED DOWN

PIPE TEE

PIPE UNION

PIPE TRANSITION

NATURAL GASNG

TO BE DEMOLISHEDNG

EXISTING TO REMAINNG

NG PIPE SIZE, SYSTEM AND FLOW TAG (DIA)

NEW CONNECTION INTO EXISTING PIPE OR DUCT

KEYNOTE

THERMOSTATT

MECHANICAL SYMBOLS LEGEND

GATE VALVE

GUH-1 GUH-2

MVSB 1

7,316.75 SF

GUH-3

1/2" NG1/2" NG1/2" NG

4ø FEA 4ø FEA4ø FEA

30 MBH

5-14" WC

45 MBH

5-14" WC

30 MBH

5-14" WC

4ø CA 4ø CA 4ø CA

1" NG DN

3/4" NG

1/2" NG

3/4" NG

3/4" NG

EXISTING GAS SERVICE

ENTRANCE LOCATED AT

THE ARMORY BUILDING METER

ALL PRESSURE REGULATORS SHALL HAVE

RELIEF VENT PIPING ROUTED TO A SAFE

OUTDOOR LOCATION

GAS UNIT HEATER GUH-1

(30 CFH AT 5-14" WC)

GAS UNIT HEATER GUH-2

(45 CFH AT 5-14" WC)

GAS UNIT HEATER GUH-3

(30 CFH AT 5-14" WC)

1/2" 1/2"

MVSB1 BUILDING

APPROXIMATELY 300 FEET

1" (0.5 PSI)

1" (0.5 PSI)

EXISTING

DEHUMIDIFIER

(51.3 CFH AT MAX

14" WC)

3/4" (0.5 PSI)

3/4"

EXISTING

DEHUMIDIFIER

(51.3 CFH AT MAX

14" WC)

MVSB2 BUILDING

EXISTING

CORAYVAC

(80 CFH AT MAX

14" WC)

ASSUMED LOAD

EXISTING

CORAYVAC

(80 CFH AT MAX

14" WC)

ASSUMED LOAD

3/4"

G

PRESSURE REGULATOR

6" DIRT LEG

SHUT-OFF VALVE

UNION

FLUE STACK

DOUBLE WALL

TYPE B GAS VENT

PROVIDE METAL ROOF

PIPE BOOT W/

ALUMINUM LINED BASE

AT DUCT PENETRATION

THROUGH ROOF.

A P

P R

O V

E D

B Y

D R

A W

N B

Y

IS

S

U E

D F

O R

IS

S

U E

D A

T E

P R

O J E

C T

N U

M B

E R

F

IE

L D

B O

O K

.7

.0

S

H

IV

E -H

A T

T E

R Y

.C O

M

BA D E

FC G

H

BA D E FC G H

Autodesk Revit 2024Autodesk Revit 2024

/1

/2

:0 :5

P

M

A u to d e s k D o c s /2

I A

N G

C lin to n M

V S

B Im p /2

-M

E P

-R -I

A N

G

C lin to n M

V S

B I m p .r v t

M E

C H

A N

IC

A

L P

L A

N

B

ID

T L S

T L S

/1

/2

M100

IO

W

A A

R M

Y N

A T

IO

N

A L

G U

A R

T C

L

IN

T O

N M

V S

B

A L

T E

R A

T

IO

N

Io w a A rm y N a ti o n a l G u a rd th

A v e N

C lin to n

IA

NORTH

1/8" = 1'-0"C5

MECHANICAL PLAN

12'

5. SINGLE STAGE THERMOSTAT.

4. DOWNTURN NOZZLE CD2.

3. SINGLE STAGE GAS VALVE.

2. FOUR POINT SUSPENSION.

1. PROVIDE WITH SEPARATED COMBUSTION CONVERSION KIT

REMARKS:

UNIT HEATER SCHEDULE - GAS

MARK AREA SERVED CFM EAT (°F) LAT (°F)

GAS MOUNTING

HEIGHT (FT) ORIENTATION

FAN MOTOR DATA

DESIGN BASIS REMARKSINPUT (MBH) OUTPUT (MBH) HP VOLTS PHASE DISCONNECT FURNISHED / INSTALLED

GUH-1 MVSB-1 506 40 85 30 24.6 12' - 0" HORIZONTAL 1/6 120 1 MFR REZNOR UBXC

GUH-2 MVSB-1 759 40 85 45 36.9 12' - 0" HORIZONTAL 1/6 120 1 MFR REZNOR UBXC

GUH-3 MVSB-1 506 40 85 30 24.6 12' - 0" HORIZONTAL 1/6 120 1 MFR REZNOR UBXC

NOT TO SCALED6

GAS PIPING SCHEMATIC

NOT TO SCALEG6

GAS UNIT HEATER

/2

5/

1. ALL WORK SHALL BE IN CONFORMANCE WITH THE NATIONAL

ELECTRICAL CODE - LATEST EDITION ADOPTED BY THE STATE,

THE STATE AMENDMENTS, LOCAL/MUNICIPAL CODES AND

ORDINANCES, AND THE AUTHORITY HAVING JURISDICTION.

THE COMPLETE INSTALLATION SHALL BE IN ACCORDANCE

WITH THE ADAAG (AMERICANS WITH DISABILITIES ACT

ACCESSIBILITY GUIDELINES).

2. IT IS THE INTENT OF THESE DOCUMENTS TO COMPLY WITH

THE APPLICABLE CODES. WHERE DISCREPANCIES OCCUR,

NOTIFY THE ENGINEER/ARCHITECT IN WRITING FOR

INTERPRETATION. CORRECT ANY INSTALLATION THAT FAILS

TO COMPLY WITH THE CODES AND STANDARDS AT NO

ADDITIONAL COST TO THE OWNER.

3. CONTRACTOR SHALL PROVIDE ALL WORK NECESSARY

INCLUDING ALL LABOR, MATERIALS, PERMITS, TAXES, FEES,

INSPECTIONS, HARDWARE, AND COST FOR INSTALLATION FOR

A COMPLETE AND OPERATIONAL SYSTEM.

4. ALL MATERIALS FURNISHED BY THE CONTRACTOR SHALL BE

NEW, COMPLETE WITH MANUFACTURER’S GUARANTEE OR

WARRANTY AND SHALL BE LISTED BY A NATIONALLY

RECOGNIZED TESTING LABORATORY (NRTL).

5. COORDINATE ELECTRICAL INSTALLATION WITH ALL TRADES

PRIOR TO INSTALLATION. IF ELECTRICAL WORK INSTALLED

INTERFERES WITH OTHER TRADES AFTER INSTALLATION, THE

CONTRACTOR SHALL MAKE ALL NECESSARY CHANGES TO

CORRECT THE CONDITION AT NO ADDITIONAL COST TO THE

OWNER.

6. DRAWINGS ARE DIAGRAMMATIC. ALL DIMENSIONS SHOWN ARE

APPROXIMATE. CONTRACTOR SHALL VERIFY ALL FURNITURE,

MODULAR FURNITURE, AND EQUIPMENT LOCATIONS WITH

ARCHITECTURAL PLANS, ELEVATIONS AND REVIEWED SHOP

DRAWINGS. PRIOR TO MAKING THE ACTUAL ELECTRICAL

INSTALLATION THIS CONTRACTOR SHALL ADJUST

CONNECTION LOCATIONS TO ACCOMMODATE FURNITURE

AND/OR EQUIPMENT.

7. ALL ELECTRICAL PANELS WITH ANY BRANCH CIRCUIT/LOAD

REVISIONS (DEMOLITION OR NEW WORK) SHALL HAVE A NEW

TYPED UPDATED CIRCUIT DIRECTORY CARD INSTALLED INSIDE

THE DOOR OF THE ELECTRICAL PANEL. THE CONTRACTOR

SHALL VERIFY THAT ALL UNUSED CIRCUIT BREAKERS ARE

TURNED ‘OFF’ AND PROPERLY INDICATED AS ‘SPARE’ ON THE

NEW CIRCUIT DIRECTORY CARD. THE CONTRACTOR SHALL

INSTALL FILLER PLATES WHERE BREAKERS ARE REMOVED AS

PART OF THIS PROJECT OR HAVE BEEN REMOVED

PREVIOUSLY.

8. NO ENERGIZED CONDUCTORS SHALL BE EXPOSED AT

ANYTIME EXCEPT WHEN THE IMMEDIATE AREA IS UNDER THE

SUPERVISION OF A QUALIFIED ELECTRICIAN.

9. WHERE CONDUIT IS SURFACE MOUNTED TO A WALL AND RUN

VERTICALLY DOWN TO A SWITCH/OUTLET BOX, UTILIZE 1-HOLE

OR 2-HOLE CONDUIT STRAPS.

10. REFER TO THE ARCHITECTURAL DRAWINGS FOR LOCATIONS

OF BUILDING EXPANSION JOINTS. ALL CONDUITS CROSSING

EXPANSION JOINTS SHALL BE INSTALLED WITH EXPANSION

FITTINGS, UNLESS THE CONDUIT IS BELOW SLAB IN THE

COMPACTED GRANULAR FILL. EXPANSION FITTINGS SHALL BE

INSTALLED IN ACCORDANCE WITH THE NATIONAL ELECTRICAL

CODE, AND MANUFACTURE'S WRITTEN RECOMMENDATIONS.

11. PENETRATIONS THROUGH FIRE RATED WALLS BY DIVISION 26

CONTRACTOR SHALL BE SEALED WITH APPROPRIATE FIRE

PROOFING MATERIAL TO RESTORE FIRE RATING. REFER TO

ARCHITECTURAL DRAWINGS FOR FIRE RATED WALLS.

12. THE CONTRACTOR SHALL KEEP THE WORK AREA CLEAN OF

ALL DEBRIS ON A DAILY BASIS. ALL NEW MATERIALS AWAITING

INSTALLATION SHALL BE KEPT IN AREAS DESIGNATED BY THE

OWNER.

13. THESE DRAWINGS SHALL NOT BE SCALED TO OBTAIN

DIMENSIONS. REFER TO DIMENSIONED ARCHITECTURAL

FLOOR PLANS. IF THE DIMENSIONS CANNOT BE DETERMINED

BY THE INFORMATION GIVEN, CONTRACTOR SHALL CONTACT

THE ENGINEER FOR ADDITIONAL INFORMATION.

14. PERIODIC SITE OBSERVATION BY THE ENGINEER IS SOLELY

FOR THE PURPOSE OF DETERMINING IF THE WORK OF THE

CONTRACTOR IS PROCEEDING IN ACCORDANCE WITH THE

CONTRACT DOCUMENTS. THIS LIMITED SITE OBSERVATION

SHOULD NOT BE CONSTRUED AS EXHAUSTIVE OR

CONTINUOUS TO CHECK THE QUALITY OR QUANTITY OF THE

WORK, BUT RATHER PERIODIC IN AN EFFORT TO GUARD THE

OWNER AGAINST DEFECTS OR DEFICIENCIES IN THE WORK OF

THE CONTRACTOR.

15. THE INFORMATION CONTAINED ON THE ELECTRICAL

DRAWINGS IS IN ITSELF INCOMPLETE AND VOID UNLESS USED

IN CONJUNCTION WITH ALL OTHER DISCIPLINE DRAWINGS,

THE SPECIFICATIONS, TRADE PRACTICES, OR APPLICABLE

STANDARDS, CODES, ETC., AND SHALL BE CONSIDERED THE

CONTRACT DOCUMENTS AND WITH ALL THEREIN BY

REFERENCE, WHICH THE CONTRACTOR CERTIFIES

KNOWLEDGE OF BY SIGNING THE CONTRACT.

16. CONTRACTOR IS TO ASSUME FULL RESPONSIBILITY,

UNRELIEVED BY REVIEW OF SHOP DRAWINGS OR PERIODIC

OBSERVATION OF CONSTRUCTION, FOR COMPLIANCE WITH

THE CONTRACT DOCUMENTS, FOR DIMENSIONS TO BE

CONFIRMED AND CORRELATED ON THE JOB SITE AND

BETWEEN INDIVIDUAL DRAWINGS OR SETS OF DRAWINGS FOR

FABRICATION PROCESSES AND CONSTRUCTION TECHNIQUES

(INCLUDING EXCAVATION, SHORING, SCAFFOLDING, BRACING,

ERECTION, FORM WORK, ETC.), FOR COORDINATION OF THE

VARIOUS TRADES, AND FOR SAFE CONDITIONS ON THE JOB

SITE. VARIATIONS IN FIELD CONDITIONS RELATIVE TO THE

CONTRACT DOCUMENTS SHALL BE REPORTED TO THE

ENGINEER AS SOON AS THEY ARE FOUND. WORK SHALL NOT

PROGRESS UNTIL WRITTEN PERMISSION FROM THE ENGINEER

IS OBTAINED.

ELECTRICAL

1. LIGHT LINES INDICATE EXISTING WALLS AND EQUIPMENT TO

REMAIN. DASHED LINES INDICATE WALLS, EQUIPMENT, AND

ELECTRICAL ITEMS TO BE REMOVED.

2. COORDINATE PATCHING REQUIREMENTS FOR UNUSED

OPENINGS WITH THE GENERAL CONTRACTOR. GENERAL

CONTRACTOR SHALL PATCH ALL UNUSED OPENINGS.

PATCHWORK SHALL MATCH MATERIALS, FINISH, AND TEXTURE

OF ADJACENT SURFACES.

3. FIRE ALARM - REMOVE EXISTING CEILING MOUNTED DEVICES

TO PERMIT REMOVAL OF CEILING. WALL MOUNTED

NOTIFICATION DEVICES SHALL BE DEMOLISHED. COORDINATE

WORK WITH PROJECT PHASING TO MAINTAIN FIRE ALARM

SYSTEM PROTECTION OF SPACES AT ALL TIMES. INCLUDE

COSTS OF ALL TEMPORARY DEVICES IN THE BID.

4. SECURITY/SURVEILLANCE - EXISTING DEVICES TO BE

REMOVED BY SYSTEMS VENDOR. CONTRACTOR SHALL

REMOVE ASSOCIATED CABLING, ROUGH-IN, AND POWER

WIRING. PRIOR TO ANY DEMOLITION IDENTIFY AND PROTECT

CABLING REQUIRED TO MAINTAIN THE SYSTEM IN AREAS THAT

WILL NOT BE REMODELED.

5. COORDINATE DISPOSAL OF ALL ITEMS NOT REQUESTED AS

SALVAGE BY THE OWNER.

6. TELEPHONE AND DATA HORIZONTAL CABLING SHALL BE

REMOVED COMPLETELY BACK TO THE FIRST REMAINING

DISTRIBUTION FRAME. PROTECT FIBER OPTIC AND COPPER

TRUNK CABLING SERVING DISTRIBUTION RACKS.

7. LIGHTING FIXTURES AND CONTROLS - REMOVE EXISTING

LIGHT FIXTURES, WALL SWITCHES, OCCUPANCY SENSORS,

AND ASSOCIATED WIRING. VERIFY AND MAINTAIN

CONNECTION TO EXISTING LIGHTING THAT WILL NOT BE

REMOVED BUT ARE ON COMMON CIRCUITS WITH ITEMS TO BE

REMOVED.

8. DISCONNECT OUTLETS, WIRING, AND OTHER NOTED

EQUIPMENT TO PERMIT DEMOLITION OF WALLS. VERIFY AND

MAINTAIN CONNECTION TO EXISTING OUTLETS THAT WILL NOT

BE REMOVED BUT ARE ON COMMON CIRCUITS WITH ITEMS TO

BE REMOVED.

9. DRAWINGS DO NOT IDENTIFY ALL OUTLETS, SWITCHES,

CABLING, OR EQUIPMENT TO BE REMOVED. CONTRACTOR

SHALL BECOME FAMILIAR WITH THE SITE PRIOR TO BIDDING

AND INCLUDE LABOR AND MATERIAL NECESSARY FOR

REQUIRED DEMOLITION IN THEIR BID.

10. WIRING SHALL BE REMOVED BACK TO SERVING PANEL.

INSTALLATION OF NEW CONDUCTORS IN EXISTING CONDUITS

WILL BE PERMITTED AS DESCRIBED IN THE DIVISION 26

SPECIFICATIONS.

11. HVAC EQUIPMENT NOTED FOR REMOVAL IS FOR REFERENCE

ONLY. THE ELECTRICAL CONTRACTOR SHALL REVIEW THE

MECHANICAL SYSTEMS DEMOLITION PLANS AND INCLUDE ALL

LABOR AND MATERIAL NECESSARY TO FACILITATE REMOVAL

OF EQUIPMENT AS SHOWN ON THOSE DRAWINGS. THIS SHALL

INCLUDE ALL ITEMS NOTED ON EITHER THE PLUMBING OR

MECHANICAL SERIES OF DRAWINGS.

ELECTRICAL DEMOLITION

ELECTRICAL ABBREVIATIONS

A

A

AC

ACB

AF

AFF

AL

ALT

AM

AS

AT

APPROX

ATC

ATS

AUTO

AUX

AWG

B

BAS

BD

BRKR

BLDG

B/M

BUZ

C

C

CAB

CB

CCTV

CKT

CL

CLG

COMM

CONN

CONC

COND

CONTR

CP

CPT

CR

CT

CU

D

DC

DIA

DIAG

DIM

DISC

DIV

DN

DP

DT

DWG

E

EC

EL

ELEC

EMER

EMT

ENG

EPO

ETM

EWC

EXH

EXIST

F

F

FA

FACP

FC

FDR

FF

FHP

FL

FLEX

FLR

FLUOR

FREQ

AMPERE

ABOVE COUNTER/ALTERNATING CURRENT

AIR CIRCUIT BREAKER

AMPERE RATING OF FUSE

ABOVE FINISHED FLOOR

ALUMINUM

ALTERNATE

AMMETER

AMMETER SWITCH

AMPERE TRIP RATING

APPROXIMATELY

AUTOMATIC TEMPERATURE CONTROL

AUTOMATIC TRANSFER SWITCH

AUTOMATIC

AUXILIARY

AMERICAN WIRE GAUGE

BUILDING AUTOMATION SYSTEM

BUS DUCT

BREAKER

BUILDING

BILL OF MATERIALS

BUZZER

CONTRACTOR

CABINET

CIRCUIT BREAKER

CLOSED CIRCUIT TELEVISION

CIRCUIT

CENTERLINE

CEILING

COMMUNICATIONS CONNECT, CONNECTED,

CONNECTOR

CONCRETE

CONDUCTOR

CONTRACTOR

CONTROL PANEL

CONTROL POWER TRANSFORMER

CONTROL RELAY

CURRENT TRANSFORMER

COPPER

DIRECT CURRENT

DIAMETER

DIAGRAM

DIMMER CONTROL

DISCONNECT

DIVISION

DOWN

DOUBLE POLE

DOUBLE THROW

DRAWING

ELECTRICAL CONTRACTOR

ELEVATION

ELECTRICAL

EMERGENCY

ELECTRICAL METALLIC TUBING

ENGINEER

EMERGENCY POWER OFF

ELAPSED (RUN) TIME METER

ELECTRIC WATER COOLER

EXHAUST

EXISTING

FUSE

FIRE ALARM

FIRE ALARM CONTROL PANEL

FOOTCANDLE

FEEDER

FURNITURE FEED

FRACTIONAL HORSEPOWER

FLOODLIGHT

FLEXIBLE, FLEXIBLE CONDUIT

FLOOR

FLUORESCENT

FREQUENCY

G

GC

GEC

GEN

GFI

GFP

GND

GR

GW

H

HGT

HH

HID

HP

HPS

HTR

HZ

I

IMC

INCAND

INTCONN

J

JB

JCT

K

K

KCMIL

KV

KVA

KVAR

KW

KWH

L

LG

LIM

LPS

LTG

LV

LVSS

M

MAN

MATL

MC

MCC

MCP

MFR

MH

MIC

MLO

MTG

MTR

MTS

MVA

MVAR

MW

MWH

N

NC

NF

NIC

NEC

NEMA

NO

NTS

O

OCB

OPR

OL

GENERAL CONTRACTOR

GROUNDING ELECTRODE CONDUCTOR

GENERATOR

GROUND FAULT CIRCUIT INTERRUPTER

GROUND FAULT PROTECTOR

GROUND, GROUNDING CONDUCTOR

GROUND ROD

GROUND WELL

HEIGHT

HANDHOLE

HIGH INTENSITY DISCHARGE

HORSEPOWER

HIGH PRESSURE SODIUM

HEATER

HERTZ, FREQUENCY IN CYCLES PER SECOND

INTERMEDIATE METALLIC CONDUIT

INCANDESCENT

INTERCONNECTION

JUNCTION BOX

JUNCTION

KEY OPERATED

THOUSAND CIRCULAR MILS

KILOVOLT

KILOVOLT-AMPERE

KILOVOLT-AMPERE REACTIVE

KILOWATT

KILOWATT-HOUR

LENGTH

LIMIT

LOW PRESSURE SODIUM

LIGHT, LIGHTING

LOW VOLTAGE

LOW VOLTAGE SURGE SUPPRESSION

MANUAL

MATERIAL

MECHANICAL CONTRACTOR

MOTOR CONTROL CENTER

MOTOR CIRCUIT PROTECTOR

MANUFACTURER

MANHOLE

MICROPHONE

MAIN LUGS ONLY

MOUNT, MOUNTED, MOUNTING

MOTOR

MANUAL TRANSFER SWITCH

MEGAVOLT-AMPERE

MEGAVOLT-AMPERE REACTIVE

MEGAWATT

MEGAWATT-HOUR

NORMALLY CLOSED

NON-FUSED

NOT IN CONTRACT

NATIONAL ELECTRICAL CODE

NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION

NORMALLY OPEN

NOT TO SCALE

OIL CIRCUIT BREAKER

OPERATOR, OPERATED

THERMAL OVERLOAD PROTECTION

P

P

PB

PC

PF

PFM

PNL

PRI

PS

PT

PVC

PWR

R

R

RC

RECPT

REF

REQD

RGS

S

SA

SCHD

SCHM

SP

SPKR

ST

STA

STBY

SUBSTA

SW

SWBD

SWGR

SYNC

SYS

T

T/

TB

TC

TCC

TDCD

TDCE

TDOD

TDOE

TEL

TEMP

TERM

TSTAT

TV

TYP

U

UG

UNO

UNG

UPS

V

V

VA

VAR

VERT

VFD

VM

VS

W

W W/ W/O

WH

WP

X

XDCR

XFMR

XFR

XMIT

XP

PILOT

LIGHT PUSHBUTTON

PHOTOCELL

POWER FACTOR

POWER FACTOR METER

PANEL

PRIMARY

PRESSURE SWITCH

POTENTIAL TRANSFORMER

POLVINYLCHLORIDE, PVC CONDUIT

POWER

RELAY

REMOTE CONTROL

RECEPTACLE

REFER, REFERENCE

REQUIRED

RIGID GALVANIZED STEEL CONDUIT

SURGE ARRESTER

SCHEDULE

SCHEMATIC

SINGLE POLE

LOUDSPEAKER

SINGLE THROW

STATION

STANDBY

SUBSTATION

SWITCH

SWITCHBOARD

SWITCHGEAR

SYNCHRONIZE, (ING), (ACTION)

SYSTEM

TOP OF

TERMINAL BOARD

TIMECLOCK

TEMPERATURE CONTROL CONTRACTOR

TIME DELAY CLOSE ON DENERGIZATION

TIME DELAY CLOSE ON ENERGIZATION

TIME DELAY OPEN ON DENERGIZATION

TIME DELAY OPEN ON ENERGIZATION

TELEPHONE

TEMPERATURE

TERMINAL

THERMOSTAT

TELEVISION

TYPICAL

UNDERGROUND

UNLESS NOTED OTHERWISE

UNGROUNDED

UNINTERRUPTIBLE POWER SUPPLY

VOLTS

VOLT-AMPERE

VOLT-AMPERE REACTIVE

VERTICAL

VARIABLE FREQUENCY DRIVE

VOLTMETER

VOLTMETER SWITCH

WATTS

WITH

WITHOUT

WATT-HOUR

WEATHERPROOF

TRANSDUCER

TRANSFORMER

TRANSFER

TRANSMIT, TRANSMITTER

EXPLOSION PROOF

UC

OS

LS

S

FS

TS

FB

B

L

L S

FACP

FARP

NAC

EVAC

FTR

FSCP

HVA

TCVR

T R

DR

FR

ARCR

ASCP

ARCM

E

HH

J

TV

N

NCM

NC ANNUN

NCC

K

D

OS

M

T

SURFACE CYLINDER

RECESSED DOWNLIGHT

WALL MOUNTED LIGHT

FLOOD LIGHT

POLE MOUNTED LIGHT

SURFACE LIGHT

SUSPENDED LINEAR

(+ DENOTES POWERED FROM)

RECESSED LINEAR

INDUSTRIAL STRIP LIGHT

TRACK AND TRACK LIGHT

EMERGENCY LIGHT

EXIT SIGN

LIGHT FIXTURE ON EMERGENCY CIRCUIT

SINGLE POLE SWITCH

3-WAY SWITCH

4-WAY SWITCH

KEYED SWITCH

DIMMER SWITCH

OCCUPANCY SENSOR SWITCH

MOMENTARY CONTACT SWITCH

TIMER SWITCH

PUSH BUTTON

DURESS PUSH BUTTON, UNDER COUNTER

DUPLEX RECEPTACLE

DOUBLE DUPLEX RECEPTACLE

FLOOR BOX

DUPLEX RECEPTACLE - CEILING MOUNTED

CLOCK

OCCUPANCY SENSOR

LIGHT LEVEL SENSOR

EXTERIOR PHOTOCELL

SECURITY CAMERA

CONDUIT CONCEALED IN WALL OR OVERHEAD

CONDUIT CONCEALED BELOW FLOOR

CONDUIT TRANSITION UP

CONDUIT TRANSITION DOWN

CONDUIT STUBBED OUT

BRANCH CIRCUIT HOME RUN

CABLE TRAY (TYPE DENOTED)

CONDUIT SLEEVE (SIZE DENOTED)

VOICE/DATA OUTLET (WALL OR CEILING MOUNT)

# - QUANTITY OF RJ-45 JACKS/CABLES.

ONE, UNLESS SHOWN OTHERWISE

W - DENOTES WALL PHONE

WIRELESS ACCESS POINT (WALL OR CEILING MOUNT)

# - QUANTITY OF RJ-45 JACKS/CABLES.

ONE, UNLESS SHOWN OTHERWISE

TELEVISION OUTLET (WALL OR CEILING MOUNT)

SPEAKER (WALL OR CEILING MOUNT)

INTERCOM STATION

KEYNOTE (SEE SCHEDULE)E#

SPRINKLER FLOW SWITCH

SPRINKLER VALVE TAMPER SWITCH

DUCT SMOKE DETECTOR

LINEAR HEAT DETECTOR

REMOTE TEST/STATUS STATION

AUDIO NOTIFICATION DEVICE - CEILING MOUNTED

B = BELL

C = CHIME

H = HORN

S = SPEAKER

AUDIO NOTIFICATION DEVICE - WALL MOUNTED

B = BELL

C = CHIME

H = HORN

S = SPEAKER

VISUAL NOTIFICATION DEVICE - CEILING MOUNTED

VISUAL NOTIFICATION DEVICE - WALL MOUNTED

AUDIO/VISUAL NOTIFICATION DEVICE -

CEILING MOUNTED

B = BELL

C = CHIME

H = HORN

S = SPEAKER

AUDIO/VISUAL NOTIFICATION DEVICE -

WALL MOUNTED

B = BELL

C = CHIME

H = HORN

S = SPEAKER

FIRE ALARM CONTROL PANEL

FIRE ALARM RELAY PANEL

NAC POWER SUPPLY

VOICE EVACUATION PANEL

FIRE ALARM TRANSPONDER

FIRE SUPPRESSION CONTROL PANEL

HVAC PRESSURIZATION PANEL

FIRE ALARM TRANSCEIVER PANEL

BEAM SMOKE DETECTOR

T = TRANSMITTER/RECEIVER

R = REFLECTOR

DOOR HOLDER/HOLD OPEN

SMOKE DAMPER RELEASE

FIRE ALARM SHUT DOWN RELAY

SMOKE DETECTOR

HEAT DETECTOR

AREA OF REFUGE - CALL STATION

AIR SAMPLING CONTROL PANEL

AREA OF REFUGE - MASTER

FIREFIGHTER PHONE

EMERGENCY EXIT SIGN

SPECIAL RECEPTACLE

(CEILING, WALL, AND FLOOR MOUNTED)

BOLLARD

DIRECT POWER CONNECTION -

WALL AND EQUIPMENT

HANDHOLE

JUNCTION BOX

SYMBOL DESCRIPTION

SYMBOL DESCRIPTION SYMBOL DESCRIPTION

SYMBOL DESCRIPTION

SYMBOL DESCRIPTION

SYMBOL DESCRIPTION

PENDANT LIGHT

SIMPLEX RECEPTACLE

SPLIT DUPLEX RECEPTACLE

DUPLEX RECEPTACLE ON EMERGENCY CIRCUIT

DUPLEX RECEPTACLE PLUG LOAD CONTROL

DOUBLE DUPLEX RECEPTACLE ON EMERGENCY CIRCUIT

MOTION DETECTOR (TYPE DENOTED)

DOOR SIGNAL - APARTMENT UNIT

BUZZER

D

BELL

CHIME

NURSE CALL SINGLE PATIENT STATION

37 PIN BED INTERFACE RECEPTACLE

AUXILIARY ALARM STATION, TWO JACK

EMERGENCY PULL CORD STATION

STAFF TERMINAL, TOUCHSCREEN

DUTY STATION

NURSE CALL DOME LIGHT

NURSE CALL MASTER STATION

NURSE CALL EQUIPMENT CABINET

NURSE CALL ANNUNCIATOR PANEL

STAFF ASSIST

CODE BLUE STATION

NURSE CALL STAFF STATION

CARD READER

SYMBOL DESCRIPTION

LIGHTING/CONTROLS

GENERAL POWER

COMMUNICATION/DATA

SECURITY

NURSE CALL

FIRE ALARM

ELECTRICAL SYMBOLS LEGEND

0000 SPECIALTY EQUIPMENT TAG

PL SINGLE POLE SWITCH WITH PILOT LIGHT

DOUBLE DUPLEX RECEPTACLE PLUG LOAD CONTROL

C

EXAMPLE RECEPTACLE TAG

##" - MOUNTING HEIGHT AS INDICATED.

IF OMITTED, 18" OR ABOVE COUNTER

XX - INDICATES RECEPTACLE CONFIGURATION:

GROUND CONNECTION - EXOTHERMIC WELD

GROUND CONNECTION TO STEEL OR STRUCTURE

STATIC GROUND RECEPTACLE (TYPE DENOTED)

GROUND ROD (PLAN VIEW)

LIGHTNING PROTECTION AIR TERMINAL

LIGHTNING PROTECTION CONDUCTOR SPLICE

SYMBOL DESCRIPTION

GROUNDING

XX

AC

GFI

HZ

IG

OC

USB

WP

XP

ABOVE COUNTER (COORDINATE HEIGHT)

GROUND FAULT CIRCUIT INTERRUPTER

HORIZONTALLY MOUNTED

ISOLATED GROUND

OCCUPANCY CONTROLLED

INTEGRAL USB CHARGER

WEATHERPROOF

EXPLOSION PROOF

XX

XX

FIRE ALARM - CONTINUED

MANUAL PULL STATION

GROUND BAR

ANN FIRE ALARM REMOTE ANNUNCIATOR

KEYPAD

REQUEST TO EXIT

SURFACE MOUNTED RECEPTACLE, VARIES PER TYPE

F

L S

L

B

P

RX

J

E

N

B

A

S

D

T

DH

TV

S

E

J

IC

CR

IR

MD

C

DESCRIPTIONSYMBOL

P C

WT WALL MOUNTED TOUCHPAD

# LIGHTING CONTROL DENOTATION

TROFFER LIGHT

POWER - CONTINUED

R

VFD

SURFACE RACEWAY

BRANCH PANEL WITH CLEARANCE

(SURFACE OR RECESS MOUNTED)

ELECTRICAL EQUIPMENT (SWITCHBOARD,

DISTRIBUTION PANEL)

SPECIAL CABINET

TRANSFORMER

DISCONNECT SWITCH

VARIABLE FREQUENCY DRIVE

RELAY

RECEPTACLE ON DROP CORD (DUPLEX SHOWN)

RECEPTACLE ON CORD REEL…