This is an as-built floor plan for Building 5975 (Lynx Building), located at Joint Base Elmendorf-Richardson in Alaska. The document is classified as Controlled Unclassified Information and was prepared by MAC on November 5, 2021, at a scale of 3/32" = 1'-0".

The first floor plan depicts a comprehensive medical and administrative facility spanning multiple sections across a 12-column by 8-row grid layout. The building contains numerous specialized spaces including offices (1K106-1K197), exam rooms (1K119-1K146), multiple corridors and vestibules, reception areas, waiting areas, a therapy room, hearing test facility, procedure rooms, and support spaces such as storage, mechanical, electrical, communications, and janitor areas. Four stairwells (Stair 1-1 through 4-1), one elevator (ELV1-1), and multiple corridors facilitate circulation throughout the facility. The floor plan also identifies fire protection equipment infrastructure, including an FACP fire alarm control panel, smoke detectors, manual pull stations, fire extinguisher cabinets, fire department connections, fire alarm transmitters, sprinkler heads, and emergency egress lighting with directional chevrons. Additionally, the plan indicates ceiling and wall-mounted audio/visual mass notification devices and local operating consoles positioned strategically throughout the building for emergency communications and facility operations.

View the file

Other files

Show all 11

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

OFFICE

1K109

OFFICE

1K111

OFFICE

1K110

CLASSROOM

1K107

COMM

1K165

ELECTRICAL

1K162

S/TLT

1K169

RECEPTION

1K188

OFFICE

1K187

OFFICE

1K186

OFFICE

1K185

WAITING

1K189

VESTIBULE

1K100

STAIRS

STAIR 1-1

LOBBY

1K101

CORRIDOR

1K104

OFFICE

1K184

OFFICE

1K183

OFFICE

1K182

OFFICE

1K181

LOUNGE

1K180

STORAGE

1K179

STAIRS

STAIR 2-1

OFFICE

1K176

OFFICE

1K174

OFFICE

1K172

HEARING TEST

1K175

OFFICE

1K170

OFFICE

1K168

OFFICE

1K171

JANITOR

1K173

CORRIDOR

1K103

F/TLT

1K163

M/TLT

1K164

STAIRS

STAIR 4-1

VESTIBULE

1K191

ALC

1K112

RECEPTION

1K147

OFFICE

1K145

EXAM

1K144

EXAM

1K142

EXAM

1K140

PROCEDURE

1K128

EXAM

1K146

EXAM

1K139

EXAM

1K143

EXAM

1K141

STAIRS

STAIR 3-1

LOCKER

1K124 P/TLT

1K125

SUPPLY

1K132

S/UTILITY

1K126

LOUNGE

1K156

OFFICE

1K152

OFFICE

1K151

OFFICE

1K153

OFFICE

1K149

OFFICE

1K150

OFFICE

1K133

OFFICE

1K134

GROUP RM

1K136

S/TLT

1K154

OFFICE

1K137

OFFICE

1K123

EXAM

1K122

STORAGE

1K157

OFFICE

1K121

EXAM

1K119

OFFICE

1K120

OFFICE

1K118

S/TLT

1K116

WORK AREA

1K117

MECHANICAL

1K161

CORRIDOR

1K193

OFFICE

1K135

CORR

1K138

CORR

1K114

CORRIDOR

1K130

CORR

1K115

CORRIDOR

1K113

UP

UP

UP

UP

CORRIDOR

1K159

ELEV

ELV1-1

P/TLT

1K194

PROCEDURE

1K196

OFFICE

1K197

TREATMENT

1K195

OFFICE

1K108

OFFICE

1K106

THERAPY ROOM

1K102

CORRIDOR

1K105

UP

CEILING MOUNT AUDIO ONLY DEVICES

S

FACP FIRE ALARM CONTROL PANEL

SMOKE DETECTORS

MANUAL PULL STATION

SINGLE SIDED EGRESS LIGHT W/O DIRECTION CHEVRON

SINGLE SIDED EGRESS LIGHT W/ DIRECTION CHEVRON

FIRE PROTECTION EQUIPMENT

SPRINKLER HEAD

LOCAL OPERATING CONSOLELOC

AUDIO/VISUAL WM MASS NOTIFICATION DEVICES

ALL CEILING MOUNT AUDIO/VISUAL DEVICES

FEC

FDC

FIRE EXTINGUISHER CABINET

FIRE DEPARTMENT CONNECTION CABINET

SINGLE SIDED EGRESS LIGHT W/ DUAL DIRECTION CHEVRON

N

N

FATM

FDC FIRE DEPT CONNECTION - SINGLE OUTLET

FIRE ALARM TRANSMITTER

S

SS

S

SS

S

S

S

FEC

FECFE

C

FEC

LO

C

FACP

S

S

FD

C

N N

N N

N

N

FD

C

FAPS

DUAL SIDED EGRESS LIGHT W/ SINGLE DIRECTION CHEVRON

WALL MOUNT AUDIO ONLY DEVICES

S CEILING MOUNT AUDIO ONLY DEVICES

S

MAGNETIC DOOR HOLD

B

321 4 5 6 7 8 9 10 11 12

A

C

D

E

F

G

H

B

A

C

D

E

F

G

HDATE: PREPARED BY:

CONTROLLED UNCLASSIFIED INFORMATIONDRAWING TYPE:

SCALE:

REVISION DATE REV #

321 4 5 6 7 8 9 10 11 12

FLOOR PLAN

BUILDING 5975 - 1ST FLOOR

JOINT BASE ELMENDORF-RICHARDSON

AK

LYNX BUILDING

BUILDING - 5975

MAC3/32" = 1'-0"05 NOV 2021

AS-BUILT104 NOV 2021 - MAC

A-1

Sheets and Views
ARCH Full Bleed D (24x36)

File details come from the government source that posted it. Updated .