Attachment 1

Gyrocompass System

PROVISIONING TECHNICAL DOCUMENTATION (PTD)

Date: 08/09/2012

PROVISIONING TECHNICAL DOCUMENTATION (PTD)

1.0 SCOPE

1.1 This section defines the minimum requirements for the Contractor to supply provisioning technical documentation (PTD) necessary for Coast Guard engineers to integrate the Contractor’s equipment into the design of Coast Guard vessels. Examples of PTD include, but are not limited to: hard copy paper drawings, electronic drawing files, commercial catalogue sheets, off-the-shelf tech pubs, photographs, etc.

1.2 The Contractor’s PTD shall be detailed enough to include:

1.2.1 General arrangement drawings detailing overall dimensions; required maintenance area dimensions; locations, size and type of all piping and electrical interface requirements.

1.2.2 Equipment footprint drawings detailing the foundation/mounting areas and specifying any special interface requirements as may be necessary.

1.2.3 The overall component and system weight

1.2.4 Fluid system diagrams detailing the pressure and flow characteristics and requirements shall be provided. Hydraulic system diagrams shall specify the target contamination level limit in ISO 4406 format.

1.2.5 Equipment heat rejection values, btu/hr or kw/hr.

1.2.6 Electrical schematic of each circuit detailing the voltage and amperage requirements.

1.2.7 Manual, tech pub, and/or catalogue data detailing the installation requirements for each piece of equipment.

1.3 Drawings may be submitted as electronic media (preferred) or paper copies. Electronic media must be in AUTOCAD and at least Version 2009 or later. Where electronic media is submitted it shall be with the manufacturer’s permission to use the files in Coast Guard drawings.

1.4 PTD Documents supplied as electronic media need only be one (1) copy. PTD documents supplied as paper must be at least six (6) copies.

Note: Delivery of all PTD shall be included with the proposal.