AMEND 0005 TO SOL.doc
DOC document 49 KB Posted
- Attached to
- FY 2010 DRY DOCK & REPAIR OF CGC BERTHOLF
- Solicitation number
- HSCG8510R610K16
About this file
AMENDMENT 0005
View the file
Other files
| File | Type | Posted |
|---|---|---|
| AMEND 0006 TO SOL.doc | DOC document | |
| WMSL512-001 NSC Zone Sys Comp Term Airflow Test_Rev A.pdf | ||
| WMSL512-002 NSC TP Zone Pressurization Test Before Laundry Mods.pdf | ||
| AMEND 0004 TO SOL.doc | DOC document | |
| CORRECTED SECTION B - BERTHOLF DRYDOCK.doc | DOC document | |
| AMEND 0003 TO SOL.doc | DOC document | |
| USCGC BERTHOLF_Drydock and Repair_May_2010_Rev 1A.pdf | ||
| ASC556333-HY REV E.pdf | ||
| AMEND 0002 TO SOL.doc | DOC document | |
| 750-WMSL_100_8_1_-_D 1 .dwf | DWF file | |
| AMEND 0001 TO SOL.doc | DOC document | |
| USCGC BERTHOLF_Drydock and Repair_May_2010_Rev 0.pdf | ||
| FINAL BERTHOLF DD SOLICITATION.doc | DOC document |
Show all 13
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
1. CONTRACT ID CODE
| PAGE |
| OF PAGES |
AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT
| 1 |
| 1 |
| 2. AMENDMENT/MODIFICATION NO. |
| 3. EFFECTIVE DATE |
| 4. REQUISITION/PURCHASE REQ. NO. |
| 5. PROJECT NO. (If applicable) |
| 0005 |
| 5 March 2010 |
| 21-10-850610K16 |
| 6. ISSUED BY |
| CODE |
| HSCG85 |
| 7. ADMINISTERED BY (If other than Item 6) |
| CODE |
COMMANDER, USCG
Surface Forces Logistics Center 1301 Clay Street, Suite 807N Oakland, CA 94612
| 8. NAME AND ADRESS OF CONTRACTOR (no., street, county, State and ZIP Code) |
| ( |
| 9.A AMENDMENT OF SOLICITATION NO. |
ALL PROSPECTIVE OFFERORS
HSCG85-10-R-610K16
9B. DATE (SEE ITEM 11)
27 JAN 2010
| X |
| 10A. MODIFICATION OF CONTRACT/ORDER NO. |
10B. DATED (SEE ITEM 13)
| CODE |
| FACILITY CODE |
11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS
FORMCHECKBOX
The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offers FORMCHECKBOX is extended, FORMCHECKBOX is not extended. Offers must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended, by one of the following methods: (a) By completing Items 8 and 15, and returning 2 copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the Offer submitted: or (c) By separate letter or telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEGEMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.
12. ACCOUNTING AND APPROPRIATION DATA (If required)
N/A
13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS,
IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.
A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE CONTRACT/.ORDER NO. IN ITEM 10A.
B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation data, etc)
SET FORTH IN ITEM 14, PURSUANT TO AUTHORITY OF FAR 43.103(b).
C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF: FAR 52.212-4(c) and MUTUAL AGREEMENT OF THE PARTIES
D. OTHER (Specify type of modification and authority
E. IMPORTANT: Contractor FORMCHECKBOX is not, FORMCHECKBOX is required to sign this document and return 1 copies to the issuing office.
14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)
SUBJCET: Solicitation HSCG85-10-R-610K16
Dry-Dock Repairs of USCGC BERTHOLF
The purpose of this Amendment is to answer a Request for Clarification and provide certain documents.
Continued on Next Page
Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.
| 15A. NAME AND TITLE OF SIGNER (Type or print) |
| 16A NAME AND TITLE OF CONTRACTING OFFICER (Type or print) |
JO ANN T. YAMANE
| 15B. CONTRACTOR/OFFEROR |
| 15C. DATE SIGNED |
| 16B. UNITED STATES OF AMERICA |
| 16C. DATE SIGNED |
BY
(Signature of person authorized to sign)
(Signature of Contracting Officer)
NSN 7540-01-152-8070
30-105
STANDARD FORM 30 (REV. 10-83
A. QUESTION: “I've been asked to supply an estimate for item #9 "Ventilation System Balancing " in the Drydock and Repair specifications for the CGC Bertholf. Paragraphs 3.1.2 and 3.3.2 state that specific arrangement drawings are available upon request for the systems to be balanced.
Please advise on the best method to acquire the drawings for review.”
ANSWER: The Coast Guard believes the information necessary for estimation has been pulled from each arrangement dwg and is now listed within the test documents. Rather than sending all the arrangement dwg's. the Coast Guard requests that you look at these test documents as we believe they provide adequate information for your needs.
The attached documents, (WMSL-512-001 and WMSL-512-002), are CG deliverables called out in an excerpt from the NOTE of 3.1 within the D-9 ventilation balancing spec:
3.1 GENERAL REQUIREMENTS
Note: At the arrival conference, the government will provide two new validated test documents, WMSL-512-001 and WMSL-512-002 which will include the changes incorporated by 750-WMSL-512-501, 750-WMSL-512-502, 750-WMSL-512-503,750-WMSL-641-500, and 512-7269326. All Heating, Ventilation and Air Conditioning (HVAC) systems listed in paragraphs 3.2.1 and 3.3.1 shall be thoroughly tested and balanced to assure delivery of design air quantity to all compartments served by each system.
B. Offerors are reminded to acknowledge this Amendment by inserting their firms name in Block 8 and completing Blocks 15A, B, and C and returning a signed copy to the Contracting Officer.
File details come from the government source that posted it. Updated .