Howlett Building Storm Windows - Drawings.pdf
PDF 765 KB Posted
- Attached to
- HOWLETT 3RD FLOOR WINDOW REPAIRS
- Solicitation number
- 26-350SOS-PHYSE-B-51030
- Issued by
- Sangamon County, Illinois
About this file
This is a set of architectural drawings prepared by Evan Lloyd Associates, Inc. for the Illinois Secretary of State to address water infiltration issues at the Howlett Building, a historic structure located at 501 South 2nd Street, Springfield, Illinois. The project involves the installation of new storm windows on the 3rd floor library portion of the building to correct water infiltration at existing windows. The drawings specify the installation of eleven (11) new aluminum storm windows with 14-inch clear tempered glass panes, black anodized aluminum thermally-broken storefront frames, neoprene spacers, and stainless steel threaded rods with epoxy. The design includes a 12-inch air gap at sides and top with 12-inch neoprene spacers spaced at 3-foot 4-inch on-center intervals. The project also requires removal and reinstallation of existing bird netting, a 20-foot light pole (typical of 10), a 30-foot flag pole (typical of 2), and a steel surface-mounted handrail to facilitate construction access. The drawing set was dated December 5, 2025, with an expiration date of November 30, 2026, and includes a site plan, existing window elevation, section details, sill details, and storm window elevation views at various scales for construction reference.
The drawings specify that all existing loose paint must be removed and glass protected prior to installation, with a finishing system consisting of zinc-rich primer, epoxy intermediate coat, and epoxy top coat in a color to be selected by the owner from the manufacturer's full range. The work requires alignment with original mullions and installation of glazing from the exterior. Construction activities will occur in a brick and concrete courtyard area that must be protected during the work. No pricing, contract term, bid response dates, or award information is provided in the drawing set itself, as this is purely technical documentation supporting the project scope.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Howlett 3rd Floor Window Replacement 26PS729007.pdf | ||
| Vendor Disclosure v 24.1 Formerly Forms A~14.docx | DOCX document | |
| IPG Active Registered Vendor Disclosure formerly Forms B v.23.1~37.docx | DOCX document | |
| Change Order Notice V.25.1.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
3'- 9"
17'
-3
3'- 2"
3'- 2"
3'- 2"
3'- 2"
3'- 61 2"
7'-5"±
3"
3"
17' -4
7'-6"±
A-1
BAB
© Evan Lloyd Associates, Inc.
TC
S
E
CRADE
IO
N
AT
TIMOTHY
B. SMITH
L
SN
E
IC
S
TIH
F
TE
O ILIL
001-017445
Date:
Drawn By:
Revised:
Revised:
Project No.
SHEET
OF SHEET
Date Signed:
Expiration Date:
S ou th Si xth S tre et
Sp rin gfi eld
, Il lin ois
Ph on e
7.7
.70
NE
W
S
TO
RM
W
IN
DO
W S
HO
W
LE
TT
B
UI
LD
IN
G
1 S
OU
TH
2N
D
ST
RE
ET
SP
RI
NG
FI
EL
D, IL
LIN
OI
S
DEC. 5, 2025
25056
DEC. 5, 2025
NOV. 30, 2026
33'-0"±
0'-0"
12" AIR GAP AT
SIDES AND TOP
12" NEOPRENE SPACER
12" DIA. HOLE FOR S.S. 38"x8"
THREADED ROD WITH EPOXY
14" TEMPERED GLASS
2"X412" BLACK ANODIZED ALUM.
THERMALLY-BROKE STOREFRONT FRAME.
INSTALL GLAZING FROM EXTERIOR. EXIST. STEEL FRAME
WINDOW (PAINT)
EXIST. STEEL FRAME WINDOW - PAINT
EXIST. STONE SILL
EXIST. STONE WALL
12"x3" NEOPRENE SPACER @
3'-4" O.C. (TYP OF 10)
EXISTING BIRD NETTING.
CONTRACTOR TO REMOVE AND
REINSTALL FOR ACCESS AS NEEDED
EXIST 20'-0"± LIGHT POLE (TYP OF 10)
EXIST 30'-0"± FLAG POLE (TYP OF 2)UP
UP
UP
UP
UP
PARKING LOT
REMOVE AND REINSTALL STEEL
SURFACE-MOUNTED HANDRAIL AS
NEEDED FOR ACCESS
BRICK AND CONCRETE COURTYARD
(PROTECT DURING CONSTRUCTION)
NEW STORM WINDOW (TYP OF 11)
SCALE: 18" = 1'-0"
SITE PLAN1
SCALE: 14" = 1'-0"
SECTION3
SCALE: 112" = 1'-0"
SILL DETAIL4 SCALE: 12" = 1'-0"
STORM WINDOW ELEVATION5
SCALE: 14" = 1'-0"
EXIST. WINDOW ELEVATION2
NOTES:
1. REMOVE ALL LOOSE PAINT
2. PROTECT GLASS
PRIMER: ZINC RICH
INTERMEDIATE COAT: EPOXY
TOP COAT: EPOXY
COLOR: SELECTED BY OWNER FROM
MANUFACTURER'S FULL RANGE
2, 5 A-1
TYP
A-1
UP
SEALANT
A-1
NORTH
ALIGN WITH
ORIGINAL MULLIONS
EXISTING
STEEL
WINDOW
BEYOND
NEW STORM
WINDOW
EXISTING
WINDOW
NEW ALUM. STORM WINDOW
14" CLEAR, TEMPERED GLASS
12"x3" NEOPRENE
SPACER
TYPICAL NEOPRENE SPACER
| Sheets and Views |
| Layout |
File details come from the government source that posted it. Updated .