Hines Finance Center - Drawings 6-14-2021.pdf
PDF 12 MB Posted
- Attached to
- Y1DZ--Hines Finance Center Renovation
- Solicitation number
- 36C10E21R0009
About this file
This document outlines a solicitation for renovation services at the Hines Finance Center in Hines, Illinois. The Department of Veterans Affairs Veteran Benefits Administration Headquarters is seeking to renovate approximately 7,651 square feet of existing office and break room space. The scope of work includes demolishing interior walls and ceilings, replacing the access flooring system, installing new flooring, wall finishes, casework and plumbing fixtures. Mechanical, electrical and low voltage systems will be updated to support the new layout in accordance with applicable codes and standards. The period of performance is 180 days from notice to proceed.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 23 09 23.27.pdf | ||
| 23 31 13.pdf | ||
| 23 01 30.52.pdf | ||
| 36C10E21R0009 0005.docx | DOCX document | |
| 23 37 13.23.pdf | ||
| 23 09 93.11.pdf | ||
| 36C10E21R0009 0004.docx | DOCX document | |
| Site Visit Sign In Sheet Page 1_10-19-2021.pdf | ||
| 36C10E21R0009 0003.docx | DOCX document | |
| Site Visit Sign In Sheet Page 2_10-19-2021.pdf | ||
| 36C10E21R0009 0002.docx | DOCX document | |
| 36C10E21R0009 0001.docx | DOCX document | |
| Wage Determination for Cook County 9-24-2021.pdf | ||
| 201VB3032 Hines Finance Center - Specifications_6-14-2021.pdf | ||
| 36C10E21R0009.docx | DOCX document |
Show all 15
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
HINES FINANCE
CENTER
7,325 SQFT
599 SQFT
BREAK
ROOM
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Benefits
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
Drawing Number
Drawing # OF
U.S. DEPARTMENT OF VETERANS AFFAIRS
VA Health Care System Approval:
MECH / ELEC / PLUMB / TECH ENGINEER
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(913) 369-7200
FULLY SPRINKLERED
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:ARCHITECT / ENGINEER:
SPUR SBBL COLLABORATIVE JV, INC
100 N. STONE AVENUE, STE 1102
TUCSON, AZ 85701
(405) 842-6100
IL ARCH. LICENSE NO.: 001023503 EXP. 11/30/22
IL MECH. ENGR. LICENSE NO.: 062.071715 EXP. 11/30/21
IL ELECT. ENGR. LICENSE NO.: 062.072296 EXP. 11/30/21
/1
/2
:4 :4
P
M
GI-000
COVER SHEET
JET 1 29TAB
100% DESIGN
HINES FINANCE CENTER
VA PROJECT NUMBER: 201VB3032
HINES FINANCE CENTER
06/14/2021
201VB3032
STATION 201, BLDG 215, STE 200X
1ST AVENUE NORTH 22ND STREET
HINES, IL 60141
VETERAN BENEFITS ADMINISTRATION
STATION 201, BLDG 215, STE 200X
1ST AVENUE NORTH 22ND STREET
HINES, IL 60141
100% DESIGN
SHEET INDEX
SEQ NUMBER SHEET NAME
[01] GENERAL
1 GI-000 COVER SHEET
2 GI-001 GENERAL INFORMATION
3 GI-011 LEVEL 2 - LIFE SAFETY PLAN
[02] ARCHITECTURAL
4 AD-100 LEVEL 2 - DEMOLITION FLOOR PLAN
5 AD-200 LEVEL 2 - DEMOLITION REFLECTED CEILING PLAN
6 AE-100 LEVEL 2 - FLOOR PLAN - DIMENSION PLAN
7 AE-101 LEVEL 2 - FLOOR PLAN - FF&E
8 AE-102 LEVEL 2 - FLOOR PLAN - FLOOR FINISH
9 AE-200 LEVEL 2 - REFLECTED CEILING PLAN
10 AE-300 INTERIOR ELEVATIONS
11 AE-301 ARCHITECTURAL DETAILS
[03] FIRE PROTECTION
12 FP-100 LEVEL 2 - FIRE PROTECTION PLAN
[04] MECHANICAL
13 MP-000 MECHANICAL AND PLUMBING LEGEND AND ABBREVIATIONS
14 MD-100 LEVEL 2 - MECHANICAL HVAC DEMOLITION PLAN
15 MH-100 LEVEL 2 - MECHANICAL HVAC ZONING PLAN
16 MH-101 LEVEL 2 - MECHANICAL HVAC DUCT PLAN AND SCHEDULES
17 MH-102 LEVEL 2 - MECHANICAL HVAC PIPING PLAN
18 MH-200 MECHANICAL DETAILS
19 MH-300 MECHANICAL CONTROLS
[05] PLUMBING
20 P-100 LEVEL 2 - BREAK ROOM PLUMBING ENLARGED PLAN
[06] ELECTRICAL
21 E-000 ELECTRICAL LEGEND AND ABBREVIATIONS
22 EPD-101 LEVEL 2 - ELECTRICAL POWER DEMOLITION PLAN
23 EPD-102 LEVEL 2 - ELECTRICAL LIGHTING DEMOLITION PLAN
24 EP-101 LEVEL 2 - ELECTRICAL POWER PLAN
25 EP-102 LEVEL 2 - ELECTRICAL LIGHTING PLAN
26 EP-103 LEVEL 2 - ELECTRICAL DATA AND SECURITY PLAN
27 EP-300 ELECTRICAL ONE-LINE DIAGRAM AND DETAILS
28 EP-301 EXISTING PANEL SCHEDULES
29 EP-302 NEW PANEL SCHEDULES
TOTAL SHEETS: 29
PROJECT LOCATION
EDWARD HINES, JR. VA MEDICAL CENTER CAMPUS
N
PROJECT LOCATION
PROJECT SCOPE AREA
BUILDING 215 - LEVEL 2
N
No. REVISION DESCRIPTION DATE
Date
06/14/2021
ABBREVIATIONS CODES STANDARDS AND EXECUTIVE ORDERS
4' -0
M
A X
4' -0
M
A X
2' -1
0" M
A X
2' -3
M
IN
1'-6" MIN
1. GENERAL CONTRACTOR TO PROVIDE METAL SUPPORT
BLOCKING FOR ALL WALL MOUNTED ACCESSORIES,
FIXTURES, AND EQUIPMENT.
2. PROVIDE ADA SUPPORT BRACKETS PLACED AT ALL OPEN
COUNTERTOPS @ 36"-48" MAX ON CENTER.
3. SPECIFIED MAXIMUMS ARE MEASURED FROM AFTER
FINISHED FLOOR TO THE OPERABLE PART OF THE FIXTURE.
4. FIXTURES SHOWN ARE REPRESENTATIONAL ONLY. NOT ALL
FIXTURES MAY BE USED. REFER TO SPECIFICATIONS FOR
FIXTURE TYPES USED IN THIS PROJECT.
5. FIXTURES MAY OVERLAP WAINSCOT. WHERE APPLICABLE,
BACKING TO BE PROVIDED AS SHIM FOR FLUSH
APPLICATION. SHIM TO MATCH SCHEDULED WALL FINISH.
6" MAX
9" M
IN
SHOWER
TOILET ROOM
TURNING RADIUS
DRINKING
FOUNTAIN
PAPER TOWEL
DISPENSER
SANITARY
NAPKIN
DISPENSER
4' -0
"M A
X
WASTE
RECEPTACLE
LAVATORY
WITH MIRROR
ON CENTER
WALL
4' -0
M
A X
SOAP
DISPENSER
2' -1
0" M
A X
T O
B .O
. R E
F
LE
C T
IV
E
S U
R F
A C
E
3' -4
"M A
X
17 MIN
2' -3
M
IN
3' -0
M
A X
1'-6" MIN
WALL
2' -9
3' -1
/3 2"
M
IN
2'-0" MIN
8" MIN
WALL
LAVATORY
WITH APRON
1' -5
M
A X
1'-6" MIN
URINAL
WALL
1'-5" - 1'-7" (AMBULATORY)
1'-4" - 1'-6" (WHEELCHAIR)
CLEAR FLOOR
5'-6"
CLEAR FLOOR
6'-0"
3'-0" MIN
2' -9
3' -0
1'-0" MIN
3'-6" MIN 1'-0"MAX
4'-6" MIN
1' -5
'-7
1' -6
M
IN
A N
S I I
C C
A
7.
1)
1' -3
M
IN
A D
A /A
B A
2' -9
'-0
WALL
WALL
4' -0
M
A X
WALL HOOK
7' -0
CLOCK
WALL
FINISHED FLOOR
FIRE EXTINGUISHER
CABINET
WEIGHT > 40LBS
FIRE EXTINGUISHER
CABINET
WEIGHT < 40LBS
4' -0
"M A
X
4' -0
M
A X
TOILET SEAT
COVER
DISPENSER
BABY
CHANGING
STATION
CLEAR FLOOR SPACE
@ WATER CLOSET
5'-6"
2'-6"
4' -0
2'-6"
4' -0
HANDRAILS AND
BUMPERGUARDS
FIXTURE MOUNTING HEIGHTS AND CLEARANCES
18" MIN
M
IN
FRONT APPROACH,
PULL SIDE
36" MIN
M
IN
HINGE APPROACH,
PULL SIDE
HINGE APPROACH,
PULL SIDE
*12" MIN48
M
IN
FRONT APPROACH,
PUSH SIDE
M
IN
HINGE APPROACH,
PUSH SIDE
22" MIN 24" MIN
*4 8"
M
IN
LATCH APPROACH,
PULL SIDE
24" MIN*4
2"
M
IN
LATCH APPROACH,
PUSH SIDE
*IF BOTH CLOSER
AND LATCH ARE
PROVIDED
*54" MIN IF CLOSER
IS PROVIDED
*48" IF CLOSER IS
PROVIDED
FRONT APPROACH,
PUSH SIDE
M
IN
42" MIN
DOOR AND FIXTURE CLEARANCES
MATERIALS LEGEND
PURPOSE: THE PUBLIC BUILDINGS AMENDMENT ACT OF 1988, PUBLIC LAW (PUB. L.) 100-678 REQUIRES FEDERAL AGENCIES TO FOLLOW NATIONAL RECOGNIZED "MODEL" BUILDING CODES. THE FEDERAL PARTICIPATION IN THE DEVELOPMENT AND USE OF VOLUNTARY STANDARDS, OFFICE OF MANAGEMENT AND BUDGET (OMB) CIRCULAR A-119, REQUIRES ALL EXECUTIVE AGENCIES TO RELY ON VOLUNTARY STANDARDS, BOTH DOMESTIC AND INTERNATIONAL, WHENEVER FEASIBLE, AND TO PARTICIPATE IN VOLUNTARY STANDARD BODIES.
GENERAL: VA HAS ADOPTED THE LATEST EDITION OF THE FOLLOWING CODES AND STANDARDS AS A MINIMUM FOR ALL PROJECTS PERFORMED IN THE MODERNIZATION, ALTERATION, ADDITION, OR IMPROVEMENT OF ITS REAL PROPERTY AND THE CONSTRUCTION OF NEW STRUCTURES. VA DESIGN MANUALS AND MASTER SPECIFICATIONS SPECIFY OTHER CODES AND STANDARDS THAT VA FOLLOWS ON ITS PROJECTS:
• VA DIRECTIVES, DESIGN MANUALS, MASTER SPECIFICATIONS, VA NATIONAL CAD STANDARD APPLICATION GUIDE, AND OTHER GUIDANCE ON THE TECHNICAL INFORMATION LIBRARY (TIL) (HTTP://WWW.CFM.VA.GOV/TIL/).
• 2019 ADMINISTRATIVE PROVISIONS OF THE CHICAGO CONSTRUCTION CODES (14A)
• 2019 CHICAGO BUILDING CODE (14B)
• 2019 CHICAGO CONVEYANCE DEVICE CODE (14C)
• 2019 CHICAGO ELECTRICAL CODE (14E)
• 2019 INTERIM CHICAGO FIRE PREVENTION CODE (14F)
• 2019 INTERIM CHICAGO FUEL GAS CODE (14G)
• 2019 INTERIM CHICAGO MECHANICAL CODE (14M)
• 2019 CHICAGO ENERGY CONSERVATION CODE (14N)
• 2019 INTERIM CHICAGO PLUMBING CODE (14P)
• 2019 CHICAGO BUILDING REHABILITATION CODE (14R)
• 2019 CHICAGO MINIMUM REQUIREMENTS FOR EXISTING BUILDINGS (14X)
• 2017 NFPA 101 LIFE SAFETY CODE (SEE NOTES BELOW)
• 2021 INTERNATIONAL FIRE CODE
• 2021 NFPA 5000 BUILDING CONSTRUCTION AND SAFETY CODE
• 2019 NFPA 900 BUILDING ENERGY CODE
• OCCUPATIONAL, SAFETY AND HEALTH ADMINISTRATION (OSHA) STANDARDS.
• 2019 VA SEISMIC DESIGN REQUIREMENTS, H-18-8
• 2016 SAFETY CODE FOR ELEVATORS AND ESCALATORS, AMERICAN SOCIETY OF MECHANICAL ENGINEERS (ASME) A 17.1.
• 2015 ARCHITECTURAL BARRIERS ACT (ABA) STANDARDS INCLUDING VA SUPPLEMENT, VA BARRIER FREE DESIGN STANDARD (PG-18-13)
• 2017 ANSI ICC A117.1 ACCESIBLE AND USABLE BUILDINGS AND FACILITIES
• 2019 BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE AND COMMENTARY, AMERICAN CONCRETE INSTITUTE AND COMMENTARY (ACI 318-19)
• 2017 STEEL CONSTRUCTION MANUAL (15TH EDITION), AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC)
• ENERGY POLICY ACT OF 2005 (EPACT)
• 2007 DOE INTERIM FINAL RULE: ENERGY CONSERVATION STANDARDS FOR NEW FEDERAL, COMMERCIAL AND MULTI-FAMILY HIGH-RISE RESIDENTIAL BUILDINGS AND NEW LOW-RISE RESIDENTIAL BUILDINGS, 10 CFR PARTS 433, 434 AND 435.
• 2006 FEDERAL LEADERSHIP IN HIGH PERFORMANCE AND SUSTAINABLE BUILDINGS: MEMORANDUM OF UNDERSTANDING (MOU)
• 2018 EXECUTIVE ORDER 13834: EFFICIENT FEDERAL OPERATIONS
• 2021 THE PROVISIONS FOR CONSTRUCTION AND SAFETY SIGNS. STATED IN THE GENERAL REQUIREMENTS SECTION 010000 OF THE VA MASTER CONSTRUCTION SPECIFICATION.
• 2019 VENTILATION FOR ACCEPTABLE INDOOR AIR QUALITY – ASHRAE STANDARD 62.1
• 2019 SAFETY STANDARD FOR REFRIGERATION SYSTEMS – ASHRAE STANDARD 15
LOCAL CODES: AS AN AGENCY OF THE FEDERAL GOVERNMENT, VA IS NOT SUBJECT TO LOCAL IMPOSITION OF CODE ENFORCEMENT PROCEDURES (DRAWING REVIEWS, BUILDING PERMITS, INSPECTIONS, FEES, ETC.). VA MUST FUNCTION AS THE AUTHORITY HAVING JURISDICTION (AHJ) AND THUS HAS THE RESPONSIBILITY TO GUARD PUBLIC HEALTH AND SAFETY THROUGH ENFORCING ITS ADOPTED CODES. HOWEVER, LOCAL AUTHORITIES SHOULD BE NOTIFIED ABOUT PLANNED PROJECTS AND GIVEN OPPORTUNITY TO REVIEW DRAWINGS PROVIDED THAT VA DOES NOT PAY FOR REVIEW OR INSPECTION FEES.
NOTES:
1. NFPA 101 PRIMARILY ADDRESSES LIFE SAFETY AND FIRE PROTECTION FEATURES WHILE THE IBC ADDRESSES A WIDE RANGE OF CONSIDERATIONS, INCLUDING, BUT NOT LIMITED TO, STRUCTURAL STRENGTH, SEISMIC STABILITY, SANITATION, ADEQUATE LIGHT AND VENTILATION, AND ENERGY CONSERVATION. VA BUILDINGS MUST MEET THE REQUIREMENTS OF NFPA 101 AND DOCUMENTS REFERENCED BY NFPA 101 IN ORDER TO COMPLY WITH THE ACCREDITATION REQUIREMENTS OF THE JOINT COMMISSION. THEREFORE, DESIGNS SHALL COMPLY WITH THE REQUIREMENTS OF THE LATEST EDITION OF NFPA 101 AND DOCUMENTS REFERENCED THEREIN. DESIGN FEATURES NOT ADDRESSED BY NFPA 101 OR DOCUMENTS REFERENCED THEREIN SHALL COMPLY WITH THE REQUIREMENTS OF THE LATEST EDITION OF THE IBC OR AS OTHERWISE ADDRESSED ABOVE IN THIS PROGRAM GUIDE. FOR DESIGN FEATURES THAT ARE ADDRESSED BY BOTH THE IBC AS WELL AS NFPA 101 OR A DOCUMENT REFERENCED BY NFPA 101, THE REQUIREMENTS OF NFPA 101 OR THE DOCUMENT REFERENCED BY NFPA 101 SHALL BE USED EXCLUSIVELY
(THIS APPLIES EVEN IF THE IBC REQUIREMENTS ARE DIFFERENT).
2. CONFLICTS BETWEEN NATIONALLY RECOGNIZED CODES AND STANDARDS AND VA REQUIREMENTS – SHOULD A CONFLICT EXIST BETWEEN VA REQUIREMENTS AND VA ADOPTED NATIONALLY RECOGNIZED CODES AND STANDARDS, THE CONFLICT SHALL BE BROUGHT TO THE ATTENTION OF VA. THE RESOLUTION OF THE CONFLICT SHALL BE MADE BY THE AUTHORITY HAVING JURISDICTION FOR VA TO ENSURE A CONSISTENCY SYSTEM WIDE.
N
1. DRAWINGS ARE PART OF A COMPLETE DOCUMENTS SET. CONTRACTOR SHALL CONFIRM ALL ITEMS REQUIRED BASED UPON THE OVERALL DESIGN INTENT OF THE ENTIRE DOCUMENT
SET.
2. CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS, PRIOR TO BEGINNING ANY WORK, TO CONFIRM THE ACCURACY OF THE DRAWINGS AND REPORT ANY DISCREPANCIES TO THE ARCHITECT. DO NOT SCALE THE DRAWINGS. FIELD VERIFY ALL DIMENSIONS AND EXISTING STRUCTURAL CONDITIONS.
3. ALL AREAS NOT INVOLVED IN THE SCOPE OF WORK FOR THIS PROJECT SHALL BE KEPT CLEAN AND FREE OF OBSTRUCTIONS AT ALL TIMES.
4. ERECT BARRICADES AND WARNING SIGNS TO DIVERT AND WARN PASSERS-BY OF THE CONSTRUCTION WORK. PROVIDE DUST PROOFING ENCLOSURES TO SEPARATE WORK AREAS
FROM THE EXISTING FACILITIES.
5. ALL TRASH AND DEBRIS TO BE REMOVED ON A DAILY BASIS.
6. PROVIDE PROTECTION FOR ALL EXISTING SURFACES AND CONDITIONS TO REMAIN IN PLACE DURING THE SCOPE OF WORK. SHOULD ANY DAMAGE OCCUR, PATCH AND REPAIR ANY
DAMAGE TO ADJACENT FINISHES TO MATCH EXISTING.
7. ANY DAMAGE CAUSED TO THE BUILDING OR OWNER EQUIPMENT SHALL BE REPAIRED OR REPLACED BACK TO ITS ORIGINAL CONDITIONS AT NO ADDITIONAL COST TO THE OWNER.
8. COVER ALL RETURN AIR GRILLES WITHIN THE AREA OF CONSTRUCTION TO PREVENT PARTICULATE MATERIAL FROM EXHAUSTING INTO SURROUNDING SPACES.
9. APPROPRIATE LIGHT FIXTURES SHALL BE TEMPORARILY SUSPENDED TO PROVIDE ADEQUATE LIGHTING LEVELS FOR CONSTRUCTION.
10. CONTRACTOR AND SUBCONTRACTORS ARE REQUIRED TO COORDINATE WITH OTHER DISCIPLINES TO INSTALL COMPLETE AND OPERATIONAL SYSTEMS. DRAWINGS, AS A WHOLE, REPRESENT A COMPLETE SET AND DEPICT REQUIREMENTS FOR COMPLETE AND OPERATIONAL SYSTEMS. INDIVIDUAL DRAWINGS MAY NOT DEPICT COMPLETE AND ACCURATE INFORMATION TO COORDINATE COMPLETE AND OPERATIONAL SYSTEMS, BUT DO SO AS AN ENTIRE DOCUMENT TO BE REFERENCED WITH OTHER INDIVIDUAL DRAWINGS. CONTRACTOR AND SUBCONTRACTORS ARE REQUIRED TO REFERENCE OTHER SHEETS AND SPECIFICATIONS AS AN ENTIRE SET OF CONSTRUCTION DOCUMENTS THAT REFLECT WORK REQUIRED TO ACHIEVE A COMPLETE AND OPERATIONAL GOAL. LACK OF COORDINATION AND REVIEW OF DRAWINGS AND SPECIFICATIONS AS AN ENTIRE DOCUMENT TO INSTALL COMPLETE AND OPERATIONAL SYSTEMS, BEING OBVIOUS AND TYPICAL INDUSTRY STANDARD, IDENTIFIED IN THE DRAWINGS AND SPECIFICATIONS, SHALL NOT BE IN ANY WAY AN ADDITIONAL COST TO
THE GOVERNMENT.
11. CONTRACTOR SHALL SUBMIT A REQUEST, IN WRITING, TO INTERRUPT ANY SUCH SERVICES TO COR (CONTRACTING OFFICER’S REPRESENTATIVE) 48 HOURS IN ADVANCE OF PROPOSED INTERRUPTION. REQUEST SHALL STATE REASON, DATE, EXACT TIME OF, AND APPROXIMATE DURATION OF SUCH INTERRUPTION. MAJOR INTERRUPTIONS OF ANY SYSTEM MUST BE REQUESTED, IN WRITING, AT LEAST 60 CALENDAR DAYS PRIOR TO THE DESIRED TIME AND SHALL BE PERFORMED AS DIRECTED BY THE COR. MAJOR INTERRUPTIONS SHALL BE COORDINATED WITH OTHER MAJOR INTERRUPTIONS AND MAY NOT BE SCHEDULED FOR ONE DISCIPLINE MORE THAN TWICE THROUGHOUT THE OVERALL CONSTRUCTION SCHEDULE UNLESS REQUESTED IN WRITING AND APPROVED BY THE COR. CONTRACTOR WILL BE ADVISED, IN WRITING, OF APPROVAL OF REQUEST, OR OF WHICH OTHER DATE AND/OR TIME SUCH INTERRUPTION WILL CAUSE THE LEAST INCONVENIENCE TO FACILITY OPERATIONS. INTERRUPTION TIME MAY BE APPROVED TO OCCUR AT TIMES OTHER THAN CONTRACTOR'S NORMAL WORKING HOURS. SCHEDULED INTERRUPTION MAY BE ON WEEKENDS OR LATE HOURS AND MAY NOT BE AN ADDITIONAL COST TO THE GOVERNMENT. COORDINATE ALL INTERRUPTIONS THAT MAY AFFECT THE NORMAL OPERATION OF THE FACILITY WITH THE COR WHEN SUBMITTING THE CONSTRUCTION SCHEDULE OR UPDATES TO THE CONSTRUCTION SCHEDULE.
12. NO ASBESTOS CONTAINING MATERIALS ARE TO BE USED ON THIS PROJECT. SPUR DESIGN, THE A/E OF RECORD, CAN CERTIFY THAT NO ASBESTOS CONTAINING BUILDING MATERIALS (ACBM) OR LEAD BASED PAINT (LBP) PRODUCTS WERE DESIGNED/SPECIFIED AS BUILDING MATERIAL IN ANY OF THE CONSTRUCTION DOCUMENTS.
GENERAL NOTES
AREA NAME
150 SF
A101
A101
SIM
A
00.0
A101
1 1
A101
LEVEL NAME
00'-00"
00'-00" 4B
3A
FIBERGLASS BATT
INSULATION
RIGID INSULATION
CONCRETE / PRECAST
CONCRETE
EARTH / SOIL
SAND, EIFS FINISH, OR
PLASTER FINISH
GYPSUM BOARD FINISH
BRICK
CONCRETE MASONRY
UNIT
STONE / CAST STONE
GYPSUM BOARD SECTION
EXTERIOR SHEATHING
BOARD SECTION
PLYWOOD SECTION
ROOM NAME
000A
150 SF
/1 A101
X0000
6"
3' -0
M
A X
ROOM TAG
AREA TAG
SPECIALTY EQUIPMENT TAG
DOOR TAG
KEYED NOTE TAG
WALL TAG
WINDOW TAG
A101
SIM
A101
SIM
A
ACST ACOUSTIC
ADA AMERICANS WITH DISABILITIES ACT
ACT ACOUSTICAL CEILING TILE
ADDL ADDITIONAL
ADDN ADDITION
ADJ ADJACENT, ADJOINING, OR
ADJUSTABLE
ADMIN ADMINISTRATION
AE ARCHITECT/ENGINEER
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
AHJ AUTHORITY HAVING JURISDICTION
AIA AMERICAN INSTITUTE OF
ARCHITECTS
ALT ALTERNATE
ALT NO ALTERNATE NUMBER
AMT AMOUNT
APPROX APPROXIMATE
ARCH ARCHITECT
ASC ABOVE SUSPENDED CEILING
AVG AVERAGE
B
BD BOARD
BLDG BUILDING
BLKG BLOCKING
BLT IN BUILT-IN
BOS BOTTOM OF STEEL
BOT BOTTOM
BRKT BRACKET
BTWN BETWEEN
C
CAB CABINET
CAV CAVITY
CD CONSTRUCTION DOCUMENTS
CFM CUBIC FEET PER MINUTE
CFS CUBIC FEET PER SECOND
CIP CAST-IN-PLACE
CJ CONTROL JOINT
CL CENTER LINE
CLG CEILING
CLG HT CEILING HEIGHT
CLR COLOR
CO CONTRACTING OFFICER
COL COLUMN
COMM COMMUNICATION
CONC CONCRETE
CONT CONTINUOUS
COORD COORDINATE
COR CONTRACTING OFFICER'S
REPRESENTATIVE
CP CONTRACTOR PROVIDED
CP/CI CONTRACTOR PROVIDED /
CONTRACTOR INSTALLED
CSWK CASEWORK
CTR CENTER
CU FT CUBIC FEET
D
DBL DOUBLE
DEMO DEMOLITION
DEPT DEPARTMENT
DET DETAIL
DIA DIAMETER
DIR DIRECTION
DIST DISTANCE
DOC DOCUMENT
DR DOOR
DS DOWNSPOUT
DWG DRAWING
E
EA EACH
EJ EXPANSION JOINT
EL ELEVATION
ELEV ELEVATOR
ENTR ENTRANCE
EQ EQUAL
EX EXISTING
EXP EXPOSED
EXT EXTERIOR
F
FED FEDERAL
FF FINISH FACE
FF EL FINISH FLOOR ELEVATION
FIN FINISH
FIN BS FINISH BOTH SIDES
FIN FLR FINISH FLOOR
FIN GR FINISH GRADE
FIXT FIXTURE
FLDG FOLDING
FLEX FLEXIBLE
FLG FLOORING
FLMT FLUSH MOUNT
FLR FLOOR
FOC FACE OF CONCRETE
FOM FACE OF MASONRY
FR FIRE RESISTANT
FT FEET
FTG FOOTING
FV FIELD VERIFY
G
GR FL GROUND FLOOR
H
HDW HARDWARE
HEPA HIGH EFFICIENCY
PARTICULATE AIR (FILTER)
HORIZ HORIZONTAL
HT HEIGHT
I
IBC INTERNATIONAL BUILDING CODE
INSUL INSULATION
INT INTERIOR
ILO IN LIEU OF
J
J-BOX JUNCTION BOX
L
LAV LAVATORY
LBS POUND
LDG LANDING
LF LINEAR FEET (FOOT)
LIN LINEAR
LOC LOCATION
LT LIGHT
LVR LOUVER
M
MATL MATERIAL
MAX MAXIMUM
MECH MECHANICAL
MEMB MEMBRANE
MFR MANUFACTURER
MID MIDDLE
MIL STD MILITARY STANDARD
MIN MINIMUM
MISC MISCELLANEOUS
MO MASONRY OPENING
MOD MODIFY
MTG MOUNTING
MTL METAL
MVBL MOVABLE
N
NA NOT APPLICABLE
NIC NOT IN CONTRACT
NO NUMBER
NOM NOMINAL
NTS NOT TO SCALE
O
OA OVERALL
OC ON CENTER
OD OUTSIDE DIAMETER
OPNG OPENING
OPP OPPOSITE
OPR OPERABLE
ORD OVERFLOW ROOF DRAIN
ORIG ORIGINAL
P
PA PUBLIC ADDRESS
PCF POUNDS PER CUBIC FOOT
PCT PERCENT
PERF PERFORATED
PERIM PERIMETER
PERP PERPENDICULAR
PL PROPERTY LINE
PLBG PLUMBING
PNL PANEL
PR PAIR
PRKG PARKING
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PWR POWER
Q
QA QUALITY ASSURANCE
QC QUALITY CONTROL
QTY QUANTITY
R
RCP REFLECTED CEILING PLAN
RD ROOF DRAIN
REC RECESSED
REF REFERENCE
REM REMOVABLE
REP REPAIR
REPL REPLACE
REQ REQUIRE
REQD REQUIRED
RFG ROOFING
RM ROOM
RO ROUGH OPENING
RV ROOF VENT
S
SCHED SCHEDULE
SECT SECTION
SF SQUARE FOOT (FEET)
SGL SINGLE
SIM SIMILAR
SJ SCORED JOINT
SLNT SEALANT
SPEC SPECIFICATION
SQ SQUARE
SQ IN SQUARE INCH
SQ YD SQUARE YARD
STD STANDARD
STOR STORAGE
T
TEL TELEPHONE
TEMP TEMPORARY
TOF TOP OF FOOTING/ FOUNDATION
TOM TOP OF MASONRY
TOS TOP OF SLAB/ STEEL
U
UNO UNLESS NOTED OTHERWISE
UTIL UTILITY
V
VAR VARIES
VC VA PROVIDED / CONTRACTOR
INSTALLED
VV VA PROVIDED / VA INSTALLED
W
W/ WITH
W/O WITHOUT
W/C WATER CLOSET
WC WHEELCHAIR
WPM WATERPROOF MEMBRANE
X
X BRACE CROSS BRACE
REFERENCE SYMBOLS IDENTIFICATION TAGS
NOTE: NOT ALL ABBREVIATIONS OR SYMBOLS WILL BE UTILIZED FOR THIS PROJECT.
GRID HEAD AND
LINE
LEVEL INDICATOR
MATCH LINE AND
VIEW REFERENCE
NORTH ARROW W/
PROJECT NORTH
SPOT ELEVATION
DETAIL
SECTION
**48" MIN IF BOTH CLOSER
AND LATCH PROVIDED
WALL
SECTION
BUILDING
SECTION
DETAIL
ELEVATION
INTERIOR
ELEVATION
BUILDING
ELEVATION
1 1
6'- 0"
5'- 0"
BARIATRIC TOILET ROOM
TURNING RADIUS
CLEAR FLOOR SPACE
@ ADA LAVATORY
CLEAR FLOOR SPACE @ ADA
DRINKING FOUNTAIN
4 7/256"
6 1/32"
3"
6" 1'
-6
6" MAX
7" - 9" 11" MIN
17" - 25"
M
IN
6' -0
(ANSI ICC A117.1)
39"- 41"
(A N
S I I
C C
A
7.
1)
M
IN
(A N
S I I
C C
A
7.
1)
1"
3' -6
M
A X
5' -0
M
A X th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Benefits
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
Drawing Number
Drawing # OF
VA Health Care System Approval:
MECH / ELEC / PLUMB / TECH ENGINEER
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(913) 369-7200
FULLY SPRINKLERED
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:ARCHITECT / ENGINEER:
SPUR SBBL COLLABORATIVE JV, INC
100 N. STONE AVENUE, STE 1102
TUCSON, AZ 85701
(405) 842-6100
IL ARCH. LICENSE NO.: 001023503 EXP. 11/30/22
IL MECH. ENGR. LICENSE NO.: 062.071715 EXP. 11/30/21
IL ELECT. ENGR. LICENSE NO.: 062.072296 EXP. 11/30/21
/1
/2
:4 :4
P
M
GI-001
GENERAL INFORMATION
JET 2 29TAB
100% DESIGN
HINES FINANCE CENTER
06/14/2021
201VB3032
STATION 201, BLDG 215, STE 200X
1ST AVENUE NORTH 22ND STREET
HINES, IL 60141
No. REVISION DESCRIPTION DATE
FEC FIRE EXTINGUISHER CABINET, RECESSED
EXIT LIGHT / SIGN
BUILDING EXIT
EGRESS PATH
AREA IS NOT IN CONTRACT
EXISTING WALLS TO REMAIN
NEW CONSTRUCTION WALLS
AED AUTOMATED EXTERNAL DEFIBRILLATOR (AED)
CABINET, RECESSED
CHICAGO BUILDING CODE (14B)
BUILDING HEIGHT:
2 STORIES, 36'-0" HEIGHT
BUILDING AREA:
AREA LIMITATION: 60,000 SF PER FLOOR (TABLE 506.2)
LEVEL 2 7650 SF
TOTAL 7650 SF
BUILDING IS EQUIPPED WITH A FULLY AUTOMATIC FIRE SPRINKLER SYSTEM THROUGHOUT
CONSTRUCTION TYPE: (602.2): TYPE IIB (000)
FIRE RESISTANCE RATINGS (TABLE 601):
• COLUMNS: 0 HR
• BEAM, GIRDERS, TRUSSES: 0 HR
• FLOOR/CEILING ASSEMBLIES: 0 HR
• ROOF/CEILING ASSEMBLIES: 0 HR
• EXTERIOR NON-BEARING WALLS: 0 HR
• INTERIOR NON-BEARING WALLS: 0 HR
FIRE-RESISTIVE REQUIREMENTS:
• NON COMBUSTIBLE MATERIALS FOR STRUCTURAL FRAME, FLOORS, ROOF DECK, EXTERIOR
NON-BEARING WALLS, INTERIOR NON-BEARING WALLS (U.N.O. AT EXTERIOR)
CHAPTER 38: NEW BUSINESS OCCUPANCY
OCCUPANT LOADS (TABLE 1004.5):
• SECOND FLOOR BUSINESS USE = 100 SF/PERSON
• SECOND FLOOR WAITING AREAS WITHOUT FIXED SEATING = 15 SF/PERSON
• SECOND FLOOR ACCESSORY STORAGE = 300 SF/PERSON
OCCUPANT LOAD: 125 OCCUPANTS
SHAFTS MINIMUM 1-HOUR RATING (8.6.5)
DEAD END CORRIDOR MAXIMUM DISTANCE: 50' (1020.4 EXCEPTION 2)
MAXIMUM COMMON PATH OF TRAVEL: 115' (TABLE 1006.2.1)
MAXIMUM TRAVEL DISTANCE: 300' (TABLE 1017.2)
CORRIDOR MINIMUM FIRE RATING: 0 HR (TABLE 1020.1)
ALL EXIT DOORS PROVIDED ARE 36" LEAF MINIMUM YIELDING 34" CLEAR EXIT WIDTH.
- 0.15"/PERSON (IBC 1005.3.2, EXCEPTION 1) ALLOWS 226 OCCUPANT LOAD PER DOOR MAX.
STAIR WIDTH PROVIDED IS 44"
- .3"/PERSON (1005.3.1) ALLOWS 146 OCCUPANT LOAD AT STAIR 1 MAX.
- .3"/PERSON (1005.3.1) ALLOWS 146 OCCUPANT LOAD AT STAIR 2 MAX.
PROTECTED AREAS:
- STORAGE ROOMS - PER VA FIRE PROTECTION DESIGN MANUAL 3.1.A AND PER NFPA 101: 38.3.2.1
AND 8.7-SMOKE PARTITIONS WITH SPRINKLER PROTECTION ARE REQUIRED AND PROVIDED.
SMOKE COMPARTMENTALIZATION:
- NOT REQUIRED FOR BUSINESS OCCUPANCIES, NOT PROVIDED.
FIRE ALARM SYSTEM:
- REQUIRED / PROVIDED MANUAL SYSTEM.
STANDPIPES:
- NOT REQUIRED / NOT PROVIDED.
A
B
D
E
6 7 8
10 11 12
STAIR 1
MECHANICAL ROOM
6'-0"
6'-6"
25'-0"25'-0"25'-0"25'-0"25'-0"25'-0"25'-0"25'-0"25'-0"25'-0"
'-0
'-0
'-0
'-0
'-0
'-0
'-0
'-0
'-0
5'
-0
5'-0"
6'-6"
PROVIDE CAVITY DIVIDER UNDER ACCESS
FLOORING TO CONFIRM SMOKE SEPARATION
AT EXISTING EGRESS STAIR.
F
G
H
I
J
K
STAIR 2
ELEV.
T R
A V
E L
D
IS
T A
N C
E
3'
-0
T R
A V
E L
D
IS
T A
N C
E
6'
-0
TRAVEL DISTANCE - 72'-0"
5' -0
5' -0
6'-4 1/2"
FEC
FEC
FEC
AED
CONFERENCE
200.05
OPEN OFFICE A
200.17
DEPUTY
200.07
DEPUTY
200.08
DEPUTY
200.09
DEPUTY
200.10
COLLAB
200.11
CHIEF
200.12
CHIEF
200.13
CHIEF
200.14
CHIEF
200.15
OPEN OFFICE B
200.16
OPEN OFFICE A
200.17
BREAK ROOM
200Q
MANAGEMENT
ANALYST
200.18
RECEPTION
200.01
CHIEF
200.02
CHIEF
200.03
COLLAB
200.04
DIRECTOR
200.06
STOR
200.05.1
STOR
200.17.1
STOR
200.16.1
TRAVEL DISTANCE - 143'-0"
TRAVEL DISTANCE - 146'-0"
250'-0" th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Benefits
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
Drawing Number
Drawing # OF
VA Health Care System Approval:
MECH / ELEC / PLUMB / TECH ENGINEER
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(913) 369-7200
FULLY SPRINKLERED
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:ARCHITECT / ENGINEER:
SPUR SBBL COLLABORATIVE JV, INC
100 N. STONE AVENUE, STE 1102
TUCSON, AZ 85701
(405) 842-6100
IL ARCH. LICENSE NO.: 001023503 EXP. 11/30/22
IL MECH. ENGR. LICENSE NO.: 062.071715 EXP. 11/30/21
IL ELECT. ENGR. LICENSE NO.: 062.072296 EXP. 11/30/21
/1
/2
:4 :5
P
M
GI-011
LEVEL 2 - LIFE SAFETY PLAN
JET 3 29TAB
100% DESIGN
HINES FINANCE CENTER
06/14/2021
201VB3032
STATION 201, BLDG 215, STE 200X
1ST AVENUE NORTH 22ND STREET
HINES, IL 60141
LIFE SAFETY LEGEND
LIFE SAFETY REQUIREMENTS
N 3/32" = 1'-0"
BUILDING 215 - LEVEL 2 - LIFE SAFETY PLAN1
ROOM SCHEDULE - LIFE SAFETY
NUMBER NAME AREA OCCUPANCY TYPE LOAD FACTOR OCCUPANT LOAD
200.01 RECEPTION 262 SF WAITING AREA 15 18
200.02 CHIEF 108 SF BUSINESS 100 2
200.03 CHIEF 111 SF BUSINESS 100 2
200.04 COLLAB 88 SF BUSINESS 100 1
200.05 CONFERENCE 893 SF BUSINESS 100 9
200.05.1 STOR 35 SF ACESSORY STORAGE 300 1
200.06 DIRECTOR 203 SF BUSINESS 100 2
200.07 DEPUTY 141 SF BUSINESS 100 2
200.08 DEPUTY 142 SF BUSINESS 100 2
200.09 DEPUTY 141 SF BUSINESS 100 2
200.10 DEPUTY 142 SF BUSINESS 100 2
200.11 COLLAB 193 SF BUSINESS 100 2
200.12 CHIEF 116 SF BUSINESS 100 2
200.13 CHIEF 116 SF BUSINESS 100 2
200.14 CHIEF 115 SF BUSINESS 100 2
200.15 CHIEF 116 SF BUSINESS 100 2
200.16 OPEN OFFICE B 1047 SF BUSINESS 100 10
200.16.1 STOR 47 SF ACESSORY STORAGE 300 1
200.17 OPEN OFFICE A 1467 SF BUSINESS 100 15
200.17.1 STOR 21 SF ACESSORY STORAGE 300 1
200.17.2 PRINT 69 SF BUSINESS 100 1
200.18 MANAGEMENT ANALYST 355 SF BUSINESS 100 4
200Q BREAK ROOM 599 SF UNCONCENTRATED
ASSEMBLY
15 40
TOTAL 6530 SF
No. REVISION DESCRIPTION DATE
125 OCCUPANTS
DN
1. ALL EXISTING WALL DIMENSIONS ARE TO FINISH FACE, UNLESS OTHERWISE NOTED
2. THE CONTRACTOR SHALL VERIFY DIMENSIONS OF AS-BUILT CONDITIONS, AND
NOTIFY THE ARCHITECT IN WRITING OF ANY DISCREPANCIES. ALL INFORMATION
SHOWN ON THE CONSTRUCTION DOCUMENTS IS BASED ON FIELD OBSERVATIONS
AND/OR THE ORIGINAL CONSTRUCTION DOCUMENTS OF THE FACILITY.
3. USE CONSTRUCTION BARRIERS AS REQUIRED TO MITIGATE DUST AND DEBRIS
THROUGHOUT DEMOLITION AND CONSTRUCTION. DO NOT REMOVE BARRIERS
FROM WORK AREA UNTIL COMPLETED PROJECT AREA HAS BEEN INSPECTED BY
THE SAFETY OFFICER.
4. THE CONTRACTOR SHALL PROVIDE PROTECTIVE COVERINGS TO PROTECT
EXISTING FLOOR, WALL AND CEILING FINISHES IN EXISTING AREAS NOT
DESIGNATED FOR DEMOLITION OR NEW CONSTRUCTION. THE CONTRACTOR SHALL
BE RESPONSIBLE FOR THE REPAIR OF ANY DAMAGE CAUSED BY HIS WORK OR ANY
SUBCONTRACTOR.
5. THE CONTRACTOR SHALL VERIFY THAT NEW MECHANICAL SYSTEMS CAN BE
INSTALLED IN EXISTING SPACES TO CLEAR EXISTING CEILING AND OTHER
CONSTRUCTED ITEMS AND MAINTAIN FLOOR TO CEILING HEIGHTS INDICATED ON
DRAWINGS. IF DISCREPANCIES OCCUR DUE TO EXISTING CONDITIONS, CONSULT
WITH THE ARCHITECT BEFORE PROCEEDING.
6. THE FINISH FACE OF MATERIAL OF NEW PARTITIONS SHALL ALIGN ON BOTH SIDES
OF THE PARTITION WITH THE FACE OF THE MATERIALS ON EXISTING COLUMNS,
WALLS, OR PARTITIONS, UNLESS NOTED OTHERWISE.
7. NO WORK TO BE DONE IN AREAS HATCHED GRAY IN PLANS, HOWEVER WORK
MIGHT NEED TO BE PERFORMED IN CEILING OR EXISTING CHASES THROUGHOUT
BUILDING. REFERENCE MECHANICAL AND ELECTRICAL DRAWINGS FOR EXTENT OF
WORK. COORDINATE ACCESS TO ROOMS OUTSIDE OF SCOPE WITH OWNER.
8. CAREFULLY REMOVE AND RETAIN ANY EXISTING ARTWORK AND RETURN TO
OWNER FOR REINSTALLATION.
9. SPRINKLER CONTRACTOR IS RESPONSIBLE FOR FIELD VERIFYING THE OPERATION,
LOCATION AND ROUTING OF THE EXISTING SPRINKLER SYSTEM, INCLUDING
RELATED PIPING SYSTEMS, COMPONENTS, SPRINKLERS AND ACCESSORIES PRIOR
TO START OF PROJECT.
10. EXISTING SPRINKLER SYSTEMS TO BE MODIFIED TO CONFORM TO THE NEW
LAYOUT. ALL EXISTING SPRINKLERS, REMOVED OR DISTURBED IN RENOVATION
AREAS, SHALL BE DISPOSED OF AND REPLACED WITH NEW SPRINKLERS.
A
B
D
E
6 7 8 9 10 11 12
MECH.
200R
STAIR
200O
BREAK ROOM
200Q
2.02
2.02 2.02
2.02
2.02
2.02
2.02
2.02
2.02
2.02
2.02
2.02
2.02
2.02
2.02
2.022.02
2.02
2.032.03
2.032.03
2.03
2.03
2.03
2.03
2.03
2.03
2.04
2.02
25'-0"25'-0"25'-0"25'-0"25'-0"25'-0"
150'-0"
'-0
'-0
'-0
'-0
2.05
75'-0"
'-0
'-0
'-0
'-0
2.02 2.02
2.02
2.02
2.04
2.05
2.042.04
2.052.05
2.042.04
2.052.05
2.07
2.03
2.08
2.08
2.08
2.08
2.08
2.092.09
2.092.09
2.092.09
2.09
2.09
2.09
2.09
2.09
2.09
2.09
2.09
2.102.102.102.10 2.112.11
2.042.04
2.052.05
2.042.04
2.052.05
2.09 2.09
2.09
2.12
2.12 2.12 2.12
2.12
2.12
2.12
ALL EXISTING FURNITURE, FIXTURES, AND
EQUIPMENT IN THIS AREA TO BE STORED
AND PROTECTED FOR REUSE.
2.09
2.09
2.09
2.09
2.09
2.09
2.09
2.09
PREPARE WALL SURFACES IN THIS AREA
TO RECEIVE NEW PAINT.
EXISTING ACCESS FLOORING TO REMAIN IN
THIS AREA. PREPARE ACCESS PANELS TO
RECEIVE NEW FINISH FLOORING.
2.09
2.09
2.09
2.09
25'-0"25'-0"25'-0"
2.09
2.09
2.092.09
2.09
2.09
2.09
2.09
2.09
2.09
2.09
2.09
2.09
2.09
2.09
2.09
2.09
2.09
2.09
2.09
AREA IS NOT IN CONTRACT
EXISTING WALLS TO REMAIN
EXISTING DOOR AND FRAME TO REMAIN
X.XX KEYNOTE; REFERENCE KEYNOTE LEGEND
EXISTING WALLS TO BE DEMOLISHED
EXISTING DOOR AND FRAME TO BE DEMOLISHED
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Benefits
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
Drawing Number
Drawing # OF
VA Health Care System Approval:
MECH / ELEC / PLUMB / TECH ENGINEER
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(913) 369-7200
FULLY SPRINKLERED
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:ARCHITECT / ENGINEER:
SPUR SBBL COLLABORATIVE JV, INC
100 N. STONE AVENUE, STE 1102
TUCSON, AZ 85701
(405) 842-6100
IL ARCH. LICENSE NO.: 001023503 EXP. 11/30/22
IL MECH. ENGR. LICENSE NO.: 062.071715 EXP. 11/30/21
IL ELECT. ENGR. LICENSE NO.: 062.072296 EXP. 11/30/21
/1
/2
:4 :2
P
M
AD-100
LEVEL 2 - DEMOLITION FLOOR PLAN
JET 4 29TAB
100% DESIGN
HINES FINANCE CENTER
06/14/2021
201VB3032
STATION 201, BLDG 215, STE 200X
1ST AVENUE NORTH 22ND STREET
HINES, IL 60141
GENERAL DEMOLITION NOTES
N 1/8" = 1'-0"
LEVEL 2 - DEMOLITION FLOOR PLAN1
DEMOLITION KEYNOTE LEGEND
2.02 REMOVE EXISTING WALL AS REQUIRED FOR NEW CONSTRUCTION
2.03 REMOVE EXISTING DOOR AND FRAME
2.04 REMOVE EXISTING ACCESS FLOORING SYSTEM AND PREP EXISTING FLOOR
SURFACE FOR NEW ACCESS FLOORING SYSTEM
2.05 REMOVE EXISTING WALL BASE AND FINISHES, PREP WALL SURFACE FOR NEW
WALL BASE AND FINISHES.
2.07 REMOVE DOOR AND RETAIN. REMOVE AND PROTECT GLASS WITH ETCHED SEAL
LOGO TO BE REINSTALLED IN WINDOW AS PART OF THE RENOVATION DESIGN.
2.08 REMOVE EXISTING STORAGE CABINETS AND RETAIN FOR REUSE IN RENOVATION
DESIGN.
2.09 REMOVE EXISTING WORKSTATIONS IN ENTIRETY.
2.10 REMOVE AND RETAIN PRINTER FOR REUSE IN RENOVATION DESIGN.
2.11 REMOVE AND RETAIN BIN FOR REUSE IN RENOVATION DESIGN.
2.12 REMOVE AND RETAIN ALL ARTWORK AND RETURN TO OWNER FOR
REINSTALLATION.
DEMOLITION FLOOR PLAN LEGEND
No. REVISION DESCRIPTION DATE
A
B
D
E
6 7 8 9 10 11 12
2.202.202.202.20
2.20
MECH.
200R
STAIR
200O
BREAK ROOM
200Q
25'-0"25'-0"25'-0"25'-0"25'-0"25'-0"
150'-0"
'-0
'-0
'-0
'-0
'-0
'-0
'-0
EXISTING CEILING AND
FIXTURES TO REMAIN
IN THIS AREA ONLY
2.20
2.20
2.20 2.20
2.20
2.20
2.20
2.20
EXISTING EXIT LIGHT
EXISTING ACOUSTICAL
CEILING GRID AND TILES
EXISTING LIGHT FIXTURE
EXISTING RETURN AIR GRILLE
EXISTING SUPPLY AIR DIFFUSER
EXISTING EXHAUST AIR GRILLE
EXISTING DAYLIGHT SENSORS
AREA IS NOT IN CONTRACT
KEYNOTE; REFERENCE KEYNOTE LEGEND
EXISTING AUDIO / VISUAL FIRE ALARM
X.XX
1. ALL EXISTING WALL DIMENSIONS ARE TO FINISH FACE, UNLESS OTHERWISE NOTED
2. THE CONTRACTOR SHALL VERIFY DIMENSIONS OF AS-BUILT CONDITIONS, AND
NOTIFY THE ARCHITECT IN WRITING OF ANY DISCREPANCIES. ALL INFORMATION
SHOWN ON THE CONSTRUCTION DOCUMENTS IS BASED ON FIELD OBSERVATIONS
AND/OR THE ORIGINAL CONSTRUCTION DOCUMENTS OF THE FACILITY.
3. USE CONSTRUCTION BARRIERS AS REQUIRED TO MITIGATE DUST AND DEBRIS
THROUGHOUT DEMOLITION AND CONSTRUCTION. DO NOT REMOVE BARRIERS
FROM WORK AREA UNTIL COMPLETED PROJECT AREA HAS BEEN INSPECTED BY
THE SAFETY OFFICER.
4. THE CONTRACTOR SHALL PROVIDE PROTECTIVE COVERINGS TO PROTECT
EXISTING FLOOR, WALL AND CEILING FINISHES IN EXISTING AREAS NOT
DESIGNATED FOR DEMOLITION OR NEW CONSTRUCTION. THE CONTRACTOR SHALL
BE RESPONSIBLE FOR THE REPAIR OF ANY DAMAGE CAUSED BY HIS WORK OR ANY
SUBCONTRACTOR.
5. THE CONTRACTOR SHALL VERIFY THAT NEW MECHANICAL SYSTEMS CAN BE
INSTALLED IN EXISTING SPACES TO CLEAR EXISTING CEILING AND OTHER
CONSTRUCTED ITEMS AND MAINTAIN FLOOR TO CEILING HEIGHTS INDICATED ON
DRAWINGS. IF DISCREPANCIES OCCUR DUE TO EXISTING CONDITIONS, CONSULT
WITH THE ARCHITECT BEFORE PROCEEDING.
6. THE FINISH FACE OF MATERIAL OF NEW PARTITIONS SHALL ALIGN ON BOTH SIDES
OF THE PARTITION WITH THE FACE OF THE MATERIALS ON EXISTING COLUMNS,
WALLS, OR PARTITIONS, UNLESS NOTED OTHERWISE.
7. NO WORK TO BE DONE IN AREAS HATCHED GRAY IN PLANS, HOWEVER WORK
MIGHT NEED TO BE PERFORMED IN CEILING OR EXISTING CHASES THROUGHOUT
BUILDING. REFERENCE MECHANICAL AND ELECTRICAL DRAWINGS FOR EXTENT OF
WORK. COORDINATE ACCESS TO ROOMS OUTSIDE OF SCOPE WITH OWNER.
8. CAREFULLY REMOVE AND RETAIN ANY EXISTING ARTWORK AND RETURN TO
OWNER FOR REINSTALLATION.
9. SPRINKLER CONTRACTOR IS RESPONSIBLE FOR FIELD VERIFYING THE OPERATION,
LOCATION AND ROUTING OF THE EXISTING SPRINKLER SYSTEM, INCLUDING
RELATED PIPING SYSTEMS, COMPONENTS, SPRINKLERS AND ACCESSORIES PRIOR
TO START OF PROJECT.
10. EXISTING SPRINKLER SYSTEMS TO BE MODIFIED TO CONFORM TO THE NEW
LAYOUT. ALL EXISTING SPRINKLERS, REMOVED OR DISTURBED IN RENOVATION
AREAS, SHALL BE DISPOSED OF AND REPLACED WITH NEW SPRINKLERS.
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Benefits
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
Drawing Number
Drawing # OF
VA Health Care System Approval:
MECH / ELEC / PLUMB / TECH ENGINEER
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(913) 369-7200
FULLY SPRINKLERED
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:ARCHITECT / ENGINEER:
SPUR SBBL COLLABORATIVE JV, INC
100 N. STONE AVENUE, STE 1102
TUCSON, AZ 85701
(405) 842-6100
IL ARCH. LICENSE NO.: 001023503 EXP. 11/30/22
IL MECH. ENGR. LICENSE NO.: 062.071715 EXP. 11/30/21
IL ELECT. ENGR. LICENSE NO.: 062.072296 EXP. 11/30/21
/1
/2
:4 :2
P
M
AD-200
LEVEL 2 - DEMOLITION REFLECTED
CEILING PLAN
JET 5 29TAB
100% DESIGN
HINES FINANCE CENTER
06/14/2021
201VB3032
STATION 201, BLDG 215, STE 200X
1ST AVENUE NORTH 22ND STREET
HINES, IL 60141
N 1/8" = 1'-0"
LEVEL 2 - DEMOLITION CEILING PLAN1
DEMOLITION KEYNOTE LEGEND
2.20 REMOVE EXISTING CEILING TILE AND GRID SYSTEM THROUGHOUT. REMOVE
ALL EXISTING CEILING-MOUNTED MECHANICAL EQUIPMENT AND FIXTURES
THROUGHOUT. REFERENCE MECHANICAL DEMOLITION PLANS FOR
ADDITIONAL INFORMATION. REMOVE EXISTING CEILING-MOUNTED
ELECTRICAL EQUIPMENT AND FIXTURES THROUGHOUT. REFERENCE
ELECTRICAL DEMOLITION PLANS FOR ADDITIONAL INFORMATION.
DEMOLITION CEILING PLAN LEGEND
GENERAL DEMOLITION NOTES
No. REVISION DESCRIPTION DATE
1. ALL DOOR FRAMES TO BE LOCATED 4" FROM OUTSIDE OF FRAME TO FINISH FACE
OF ADJACENT WALL UNLESS NOTED OTHERWISE.
2. REFER TO ARCHITECTURAL DETAILS - DOORS AND WINDOWS (AE-300) FOR DOOR
AND WINDOW INFORMATION.
3. ALL NEW WALLS ARE DIMENSIONED TO CENTERLINE OF METAL STUD, UNLESS
NOTED OR SHOWN OTHERWISE. ALL EXISTING WALLS TO REMAIN ARE
DIMENSIONED TO THE FACE OF THE FINISHED WALL.
4. BLOCK OUT SLAB FOR PENETRATIONS SHALL BE 2" LARGER THAN DUCT SIZE TO
ALLOW TOLERANCE FOR DUCT PASSAGE AND FIRE SAFING. COORDINATE WITH
MEP FOR DUCT SIZES.
5. FURR AROUND ALL COLUMN PROTRUSIONS AS NEEDED UNLESS NOTED
OTHERWISE.
A
B
D
E
6 7 8 9 10 11 12
MECHANICAL ROOM
200R
STAIR 1
NIC
TOILET ROOM
200J
TOILET ROOM
200I
ELEC
200K
BREAK ROOM
200Q
116 SF
CHIEF
200.15
116 SF
CHIEF
200.13
116 SF
CHIEF
200.12
108 SF
CHIEF
200.02
142 SF
DEPUTY
200.08
142 SF
DEPUTY
200.10
111 SF
CHIEF
200.03
893 SF
CONFERENCE
200.05
115 SF
CHIEF
200.14
193 SF
COLLAB
200.11
141 SF
DEPUTY
200.09
141 SF
DEPUTY
200.07
203 SF
DIRECTOR
200.06
88 SF
COLLAB
200.04
262 SF
RECEPTION
200.01
35 SF
STOR
200.05.1
69 SF
200.17.2
355 SF
MANAGEMENT
ANALYST
200.18
1047 SF
OPEN OFFICE B
200.16
S F
C O
R R
ID
O
R
0A
S F
C O
R R
ID
O
R
0B
1467 SF
OPEN OFFICE A
200.17
S F
C O
R R
ID
O
R
0D
A1 A1A1 A1 A1A1 A1 A1A1 B1
A1A1B1
C1C1C1C1C1C1C1C1C1C1
C1
C1
C1
C1
C2
C1
C1
C1
C1
A1
A1
A1
6'-2 7/16"
6'-9 3/8"
'-3
F
.V
IDF
200L
25'-0"25'-0"25'-0"25'-0"25'-0"25'-0"
150'-0"
'-0
'-0
'-0
6'-2 7/8"
5' -4
/8
'-1
9/
6' -5
/1
6"
5'-4 11/16"
24'-10 3/4"
C1
C1
C1 C1 C1 C1 C1 C1 C1 C1 C1
A1
A1
A1
A1
B1
B1
C1
6' -4
/8
4' -4
/2
6'-6" 19'-7 1/8" F.V.
'-4
'-9
/4
24'-10 5/8"
B2
B1 A1
A1
A1A1
76'-0" F.V.
1' -3
1'-3"
5' -4
/4
B1
A1
5' -1
7/
8"
CORRIDOR
200C
B1 B1
2'-3 1/2"
3' -0
1467 SF
OPEN OFFICE A
200.17
21 SF
STOR
200.17.1
C2
C1
C1 C1C1
C1
47 SF
STOR
200.16.1
D05.2
D16.3
W1 W1
W2
D15 D14 D12 D11 D10 D09 D08 D07
D06
D
D13
D
.1
D
D
D
.2
D
.1
D
D17A
D05.3
'-1
/8
5'
-6
/1 6"
'-2
/8
'-1
5/
6' -0
/2
8'-2 1/2"
7' -1
C1
C1
C1
C1
NEW SINK AND NEW CASEWORK
NEW SANITARY WATER SUPPLY CONNECTION FOR SINK
AND EXISTING REFRIGERATOR / ICE MAKER; REFERENCE
MECHANICAL DRAWINGS FOR ADDITIONAL INFORMATION.
ALL EXISTING FURNITURE, FIXTURES, AND
EQUIPMENT IN THIS AREA TO BE STORED AND
PROTECTED FOR REUSE.
9'-4 15/16" 9'-4 7/8" 9'-4 7/8" 9'-4 7/8" 15'-4 7/8" 11'-4 7/8" 11'-4 7/8" 11'-4 7/8" 11'-4 7/8" 19'-7 5/8"
'-7
9'
-4
/4
9' -5
8'
-4
/4
'-8
/2
6'-9 3/8" 12'-2 7/16"
C1 B1
C1
A1
2'-0"
8'-0"
1'-10"
1' -1
0"
1. NOT ALL PARTITION TYPES SHOWN HERE MAY BE USED. REFER TO PLANS FOR
LOCATION AND TYPES OF EACH PARTITION.
2. PAINT CONTINUOUS 4" TALL, STENCILED LETTERS, ABOVE CEILING, ON BOTH SIDES
OF ALL FIRE AND SMOKE WALLS DESIGNATING THE PARTITION RATING INDICATED ON
THE LIFE SAFETY PLAN.
3. REFER TO FINISH SCHEDULE AND INTERIOR ELEVATIONS FOR LOCATIONS OF ALL
WALL TILE. PROVIDE AND INSTALL CEMENTITIOUS BACKER BOARD IN LIEU OF GYP BD.
AT ALL SCHEDULED TILE LOCATIONS. UNLESS NOTED OTHERWISE, TILE SHALL BE
INSTALLED PER TILE COUNCIL OF AMERICA LATEST STANDARDS FOR EACH TYPE OF
BACKING MATERIAL REPRESENTED IN WALL/PARTITION.
4. ALL SUSPENDED WALLS AND PARTITIONS SHALL HAVE GYP. BD WHICH EXTENDS A
MINIMUM OF 6" ABOVE THE SUSPENDED CEILING UNLESS SHOWN AND/OR NOTED
OTHERWISE BY THE ARCHITECT.
5. REFER TO STRUCTURAL DRAWINGS FOR ALL LOAD BEARING WALL CONDITIONS IN
REGARDS TO STRUCTURAL REQUIREMENTS.
6. "ALIGN" MEANS SIMILAR COMPONENTS OF CONSTRUCTION, E.G. WALLS, JAMBS,
ETC. SHALL ALIGN ACROSS VOIDS AND JOINTS.
7. PARTITIONS SHALL BE CONTINUOUS OVER DOORS SAME ADJACENT WALLS (UNLESS
NOTED OTHERWISE) WHERE DRYWALL CONTINUES ABOVE CEILING AND ABOVE THE
CEILING LEVEL UP TO THE STRUCTURE ABOVE. ALL GYPSUM BOARD RETURNS SHALL
HAVE CORNER BEADS MINIMUM FLOOR TO CEILING. ALL PENETRATIONS IN DRYWALL
CONSTRUCTION ABOVE FINISHED CEILING SHALL BE EFFECTIVELY SEALED TO
PREVENT SOUND LEAKAGE AND FIRE STOPPING TAPE/CAULK AT ALL RATED
PARTITIONS.
8. ALL MECHANICAL CHASES AND OTHER NOTED CHASES ARE TO EXTEND UP TO THE
UNDERSIDE OF THE DECK STRUCTURE ABOVE. ALL PLUMBING CHASES UNLESS NOTED
OTHERWISE, SHALL EXTEND ABOVE THE HIGHEST ADJOINING CEILING AND BE BRACED
TO STRUCTURE.
9. ALL CONSTRUCTION DESIGNATED TO BE SUPPORTED BY ROOF STRUCTURE SHALL
BE SUPPORTED BY TOP CHORD OF STRUCTURAL JOISTS AND NOT FROM THE METAL
DECK.
10. COORDINATE WITH MILLWORK DRAWINGS FOR PLACEMENT OF BLOCKING IN
WALLS/PARTITIONS. ALL WOOD BLOCKING IS TO BE FIRE RETARDANT TREATED.
11. IMPACT RESISTANT GYP BD. WHERE NOTED, IS OPTIONAL ABOVE 8' AFF.
12. SEAL THE TOP AND BOTTOM OF WALL AS WELL AS ALL PENETRATIONS WHERE
SMOKE PARTITIONS ARE DESIGNATED ON THE LIFE SAFETY PLAN TO ELIMINATE THE
PASSAGE OF SMOKE.
13. USE DEFLECTION TRACKS WHERE STUD WALLS ATTACH DIRECTLY TO METAL
DECK.
LINE OF
STRUCTURAL
DECK
CEILING
MATERIAL AS
SCHEDULED
WALL FINISH AS
SCHEDULED
5/8" GYP. BD. ONE
SIDE OF METAL HAT
CHANNEL 16" O.C.
BASE AND
FLOORING
AS SCHEDULED
C E
IL
IN
G H
E
IG
H T
R E
: R C
P 6"
LINE OF
STRUCTURAL
DECK
CEILING
MATERIAL AS
SCHEDULED
WALL FINISH AS
SCHEDULED
SOUND
ATTENUATION
BATTS
5/8" GYP. BD.
EACH SIDE OF
METAL STUDS
AT 16" O.C.
BASE AND
FLOORING
AS SCHEDULED
C E
IL
IN
G H
E
IG
H T
R E
: R C
P
F
LO
O R
T O
U N
D E
R S
ID
E
O F
S T
R U
C T
U R
E A
B O
V E
A1 B1
LINE OF
STRUCTURAL
DECK
CEILING
MATERIAL AS
SCHEDULED
WALL FINISH AS
SCHEDULED
SOUND
ATTENUATION
BATTS
5/8" GYP. BD.
ONE SIDE OF
METAL STUDS
AT 16" O.C.
BASE AND
FLOORING
AS SCHEDULED
C E
IL
IN
G H
E
IG
H T
R E
: R C
P
B2 C1 C2
4B
3A
ROOM NAME
000A
150 SF
AREA IS NOT IN CONTRACT
EXISTING WALLS TO REMAIN
NEW DOOR / DOOR TAG
ROOM TAG / ROOM NUMBER / AREA
PARTITION TAG
WINDOW TAG
0.
WOOD DOOR IN HOLLOW METAL FRAME
2" S
C H
E D
. D
IM
2" PER SCHED. 2"
PER SCHED.
PER MANUFACTURER
P E
R M
A N
U F
A C
T U
R E
R
P E
R S
C H
E D
U
LE
D1 D2 D3
PER SCHED.
PER MANUFACTURER
P E
R S
C H
E D
U
LE
SLIDING DOOR AND FRAME ASSEMBLY, SINGLE SLIDING DOOR AND FRAME ASSEMBLY, DOUBLE
P E
R M
A N
U F
A C
T U
R E
R
WALL BASE AS
SCHEDULED
FINISHED FLOOR
AS SCHEDULED*
Collaboration Room
VETERAN BENEF ITS ADM INISTR ATION
AE-301
AE-3011
AE-301
AE-301
AE-301
AE-301
AE-301
TEMPERED
GLASS
VA
SEAL
REUSE ETCHED GLAZING
FROM EXISTING DOOR;
REFERENCE DEMOLITION
FLOOR PLAN KEYNOTES.
3'-8"
1'-0" 1'-0" 1'-0"
4'-6"
1'-0" 1'-10" 1'-0"
INTERIOR WINDOW
ALUMINUM FRAME WITH TRIM
W1
INTERIOR WINDOW
ALUMINUM FRAME WITH TRIM
W2
2" 2" 2" 2" 2" 2" 2" 2"
WALL BASE AS
SCHEDULED
FINISHED FLOOR
AS SCHEDULED
* = TEMPERED
GLASS
1' -6
" 2" 5'
-0
2"
5' -4
2" 5'
-0
2"
5' -4
1' -6 th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Benefits
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
Drawing Number
Drawing # OF
VA Health Care System Approval:
MECH / ELEC / PLUMB / TECH ENGINEER
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(913) 369-7200
FULLY SPRINKLERED
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:ARCHITECT / ENGINEER:
SPUR SBBL COLLABORATIVE JV, INC
100 N. STONE AVENUE, STE 1102
TUCSON, AZ 85701
(405) 842-6100
IL ARCH. LICENSE NO.: 001023503 EXP. 11/30/22
IL MECH. ENGR. LICENSE NO.: 062.071715 EXP. 11/30/21
IL ELECT. ENGR. LICENSE NO.: 062.072296 EXP. 11/30/21
/1
/2
:4 :2
P
M
AE-100
LEVEL 2 - FLOOR PLAN - DIMENSION
PLAN
JET 6 29TAB
100% DESIGN
HINES FINANCE CENTER
06/14/2021
201VB3032
STATION 201, BLDG 215, STE 200X
1ST AVENUE NORTH 22ND STREET
HINES, IL 60141
DIMENSION PLAN NOTES
N 1/8" = 1'-0"
LEVEL 2 - FLOOR PLAN - DIMENSION PLAN1
GENERAL PARTITION NOTES
PARTITION SCHEDULE
MARK WALL TYPE DESCRIPTION ACTUAL WIDTH
A1 NON-INSULATED 5/8" GYPSUM BOARD ONE SIDE 7/8" HAT CHANNEL 1 1/2"
B1 INSULATED 5/8" GYPSUM BOARD ONE SIDE OF 3 5/8" METAL STUD W/ BATT INSULATION 4 1/4"
B2 INSULATED 5/8" GYPSUM BOARD ONE SIDE OF 6" METAL STUD W/ BATT INSULATION 6 5/8"
C1 INSULATED 5/8" GYPSUM BOARD EACH SIDE OF 3 5/8" METAL STUD W/ BATT INSULATION 4 7/8"
C2 INSULATED 5/8" GYPSUM BOARD EACH SIDE OF 6" METAL STUD W/ BATT INSULATION 7 1/4"
PARTITION TYPES
DIMENSION PLAN LEGEND
DOOR TYPESWINDOW TYPES
DOOR SCHEDULE
MARK TYPE
PANEL FRAME
DESCRIPTION
TYPE MATERIAL WIDTH HEIGHT RATING TYPE FINISH
D02 D2 FL WOOD / FROSTED GLASS 3'-7 1/4" 6'-11 3/4" - 2 ANODIZED ALUM SINGLE SLIDING BARN DOOR
D03 D2 FL WOOD / FROSTED GLASS 3'-7 1/4" 6'-11 3/4" - 2 ANODIZED ALUM SINGLE SLIDING BARN DOOR
D04 D2 FL WOOD / FROSTED GLASS 3'-7 1/4" 6'-11 3/4" - 2 ANODIZED ALUM SINGLE SLIDING BARN DOOR
D05.1 D3 FL WOOD / FROSTED GLASS 3'6 11/16" 6'-11 3/4" - 3 ANODIZED ALUM DOUBLE SLIDING DOOR, BI-PARTING
D05.2 D1 F WOOD 3'-6" 7'-0" - 1 HM / PAINT SINGLE SWING DOOR
D05.3 D1 F WOOD 3'-0" 7'-0" - 1 HM / PAINT SINGLE SWING DOOR
D06 D2 FL WOOD / FROSTED GLASS 3'-7 1/4" 6'-11 3/4" - 2 ANODIZED ALUM SINGLE SLIDING BARN DOOR
D07 D2 FL WOOD / FROSTED GLASS 3'-7 1/4" 6'-11 3/4" - 2 ANODIZED ALUM SINGLE SLIDING BARN DOOR
D08 D2 FL WOOD / FROSTED GLASS 3'-7 1/4" 6'-11 3/4" - 2 ANODIZED ALUM SINGLE SLIDING BARN DOOR
D09 D2 FL WOOD / FROSTED GLASS 3'-7 1/4" 6'-11 3/4" - 2 ANODIZED ALUM SINGLE SLIDING BARN DOOR
D10 D2 FL WOOD / FROSTED GLASS 3'-7 1/4" 6'-11 3/4" - 2 ANODIZED ALUM SINGLE SLIDING BARN DOOR
D11 D3 FL WOOD / FROSTED GLASS 3'6 11/16" 6'-11 3/4" - 3 ANODIZED ALUM DOUBLE SLIDING DOOR, BI-PARTING
D12 D2 FL WOOD / FROSTED GLASS 3'-7 1/4" 6'-11 3/4" - 2 ANODIZED ALUM SINGLE SLIDING BARN DOOR
D13 D2 FL WOOD / FROSTED GLASS 3'-7 1/4" 6'-11 3/4" - 2 ANODIZED ALUM SINGLE SLIDING BARN DOOR
D14 D2 FL WOOD / FROSTED GLASS 3'-7 1/4" 6'-11 3/4" - 2 ANODIZED ALUM SINGLE SLIDING BARN DOOR
D15 D2 FL WOOD / FROSTED GLASS 3'-7 1/4" 6'-11 3/4" - 2 ANODIZED ALUM SINGLE SLIDING BARN DOOR
D16.1 D2 FL WOOD / FROSTED GLASS 3'-7 1/4" 6'-11 3/4" - 2 ANODIZED ALUM SINGLE SLIDING BARN DOOR
D16.2 D1 F WOOD 3'-6" 7'-0" - 1 HM / PAINT SINGLE SWING DOOR
D16.3 D1 F WOOD 3'-0" 7'-0" - 1 HM / PAINT SINGLE SWING DOOR
D17A D1 F WOOD 3'-0" 7'-0" - 1 HM / PAINT SINGLE SWING DOOR
D18 D2 FL WOOD / FROSTED GLASS 3'-7 1/4" 6'-11 3/4" - 2 ANODIZED ALUM SINGLE SLIDING BARN DOOR
WINDOW SCHEDULE
MARK WIDTH HEIGHT SILL HEIGHT HEAD HEIGHT DESCRIPTION
W1
3'-8" 5'-4" 1'-6" 6'-10" INTERIOR WINDOW, ALUMINUM
FRAME WITH TRIM
W1
3'-8" 5'-4" 1'-6" 6'-10" INTERIOR WINDOW, ALUMINUM
FRAME WITH TRIM
W2
4'-6" 5'-4" 1'-6" 6'-10" INTERIOR WINDOW, ALUMINUM
FRAME WITH TRIM, ETCHED VA
SYMBOL IN CENTER PANEL
No. REVISION DESCRIPTION DATE
ROOM SCHEDULE
ROOM # ROOM NAME AREA
200.01 RECEPTION 262 SF
200.02 CHIEF 108 SF
200.03 CHIEF 111 SF
200.04 COLLAB 88 SF
200.05 CONFERENCE 893 SF
200.05.1 STOR 35 SF
200.06 DIRECTOR 203 SF
200.07 DEPUTY 141 SF
200.08 DEPUTY 142 SF
200.09 DEPUTY 141 SF
200.10 DEPUTY 142 SF
200.11 COLLAB 193 SF
200.12 CHIEF 116 SF
200.13 CHIEF 116 SF
200.14 CHIEF 115 SF
200.15 CHIEF 116 SF
200.16 OPEN OFFICE B 1047 SF
200.16.1 STOR 47 SF
200.17 OPEN OFFICE A 1467 SF
200.17.1 STOR 21 SF
200.17.2 PRINT 69 SF
200.18 MANAGEMENT ANALYST 355 SF
200A CORRIDOR 186 SF
200B CORRIDOR 326 SF
200C CORRIDOR 457 SF
200D CORRIDOR 149 SF
200Q BREAK ROOM 599 SF
D
E
6 7 8 9 10 11
AE-101
AE-101
AE-101
AE-101
AE-101
CHIEF
200.15
CHIEF
200.13
CHIEF
200.12
CHIEF
200.02
DEPUTY
200.08
DEPUTY
200.10
CHIEF
200.03
CONFERENCE
200.05
CHIEF
200.14
COLLAB
200.11
DEPUTY
200.09
DEPUTY
200.07
DIRECTOR
200.06
COLLAB
200.04
RECEPTION
200.01
200.17.2
MANAGEMENT
ANALYST
200.18
MECHANICAL ROOM
200R
STAIR 1
NIC
TOILET ROOM
200J
TOILET ROOM
200I
ELEC
200K
599 SF
BREAK ROOM
200Q
IDF
200L
AE-101
WS-3 WS-3 WS-3 WS-3F-3
E-6
F-3
E-1
E-2
E-2
E-1 E-1
WS-4
W S
-5
A E
-3
C O
R R
ID
O
R
0A
C O
R R
ID
O
R
0B
E-5 F-5
NEW SINK AND NEW CASEWORK
NEW SANITARY WATER SUPPLY CONNECTION FOR SINK
AND EXISTING REFRIGERATOR / ICE MAKER; REFERENCE
MECHANICAL DRAWINGS FOR ADDITIONAL INFORMATION.
EXISTING
EXISTING
E X
IS
T
IN
G
R E
F E
X
IS
T
IN
G R
E F
E X
IS
T
IN
G
R E
F
EXISTING
EXISTING
EXISTING
STOR
200.16.1
OPEN OFFICE A
200.17
OPEN OFFICE B
200.16
STOR
200.05.1
STOR
200.17.1
C O
R R
ID
O
R
0D
CORRIDOR
200C
AE-300
AE-300
AE-300
AE-300 4
W S
-1 A
W S
-1 A
W S
-1 A
W S
-1 A
W S
-1 A
W S
-1 A
W S
-1 A
W S
-1 A
W S
-1 A
W S
-1 A
W S
-1 A
W S
-1 A
W S
-1 A
W S
-1 A
W S
-1 A
W S
-1 A
W S
-1 A
W S
-1 A
W S
-1 A
W S
-1 A
W S
-1 B
W S
-1 B
WS-1B WS-1B WS-1B
WS-1B WS-1B WS-1B WS-1B WS-1B WS-1B
WS-1BWS-1BWS-1B
A E
-3
F-9
F-1
AE-3006
F-5
F-9 F-4
F-5 F-9
F-9
F-9
F-9
F-8
F-2
WS-2
WS-2
WS-2WS-2
WS-2
WS-2
F-10
F-10F-10
F-10
ALL EXISTING FURNITURE, FIXTURES, AND
EQUIPMENT IN THIS AREA TO BE STORED AND
PROTECTED FOR REUSE.
F-9F-9
F-9 F-9
F-3
F-11 F-11
FEC
FEC
AE-300 7
F-1 F-1
AED
FEC
5' -6
3'
-0
4'-4" 5" 1'-3"
8' -6
6'-0"
F-6
F-7
WS-2
2' -6
5'
-2
8' -6
WS-3
F-6
F-7 F-7
5' -6
3'
-0
8' -6
1'-3"5"4'-4"
6'-0"
2' -6
5'
-2
8' -6
WS-5
F-6
F-7
F-7
6'-0"4'-6"4'-0"
14'-6"
6' -4
8"
1' -0
8' -0
6' -0
9"
1' -3
8' -0
2'-6"
6' -0
2'-0" 2'-0" 2'-0"
2' -0
4'
-0
F-6 F-6
WS-1AWS-1A
6'-0"
WS-4
6'-0" 7'-6" 6'-0"
2' -0
4'
-6
2' -0
8' -6
19'-6"
F-6 F-6
2'-0" 3'-8" 2'-6" 3'-2" 2'-6" 3'-8" 2'-0"
4' -0
2'
-0
6' -0
WS-1B WS-1B
F-6F-6
2'-0"2'-0"2'-0"
6'-0" th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Benefits
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
Drawing Number
Drawing # OF
VA Health Care System Approval:
MECH / ELEC / PLUMB / TECH ENGINEER
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(913) 369-7200
FULLY SPRINKLERED
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:ARCHITECT / ENGINEER:
SPUR SBBL COLLABORATIVE JV, INC
100 N. STONE AVENUE, STE 1102
TUCSON, AZ 85701
(405) 842-6100
IL ARCH. LICENSE NO.: 001023503 EXP. 11/30/22
IL MECH. ENGR. LICENSE NO.: 062.071715 EXP. 11/30/21
IL ELECT. ENGR. LICENSE NO.: 062.072296 EXP. 11/30/21
/1
/2
:4 :3
P
M
AE-101
LEVEL 2 - FLOOR PLAN - FF&E
JET 7 29TAB
100% DESIGN
HINES FINANCE CENTER
06/14/2021
201VB3032
STATION 201, BLDG 215, STE 200X
1ST AVENUE NORTH 22ND STREET
HINES, IL 60141
N 1/8" = 1'-0"
LEVEL 2 - FLOOR PLAN - FURNITURE, FIXTURES, EQUIPMENT1
FURNITURE, FIXTURES, EQUIPMENT SCHEDULE
MARK DESCRIPTION QTY
EQUIPMENT
AED AUTOMATED EXTERNAL
DEFIBRILLATOR (AED) CABINET
E-1 PRINT / COPY / FAX MACHINE 7
E-2 RECYCLE BIN 4
E-3 COFFEE MAKER 1
E-4 MICROWAVE 2
E-5 TELEVISION 2
E-6 REFRIGERATOR, LARGE 2
E-7 REFRIGERATOR, SMALL 2
FEC FIRE EXTINGUISHER CABINER, SEMI
RECESSED
FURNITURE
F-1 ARTWORK 3
F-2 TABLE, CONFERENCE 1
F-3 TABLE, COLLABORATION 3
F-4 TABLE, COFFEE 1
F-5 TABLE, SIDE 3
F-6 CHAIR, TASK 74
F-7 CHAIR, GUEST 16
F-8 CHAIR, CONFERENCE 18
F-9 CHAIR, STACKABLE 43
F-10 CHAIR, RECEPTION 4
F-11 STORAGE, LOCKABLE 1
WORKSTATION
WS-1A WORKSTATION, TYPICAL (WS-1A) 20
WS-1B WORKSTATION, TYPICAL (WS-1B) 14
WS-2 WORKSTATION, CHIEF (WS-2) 6
WS-3 WORKSTATION, DEPUTY (WS-3) 4
WS-4 WORKSTATION, MGMT ANALYST (WS-4) 1
WS-5 WORKSTATION, DIRECTOR (WS-5) 1
1/4" = 1'-0" 1/ AE-101
WORKSTATION (WS-2)4
1/4" = 1'-0" 1/ AE-101
WORKSTATION (WS-3)51/4" = 1'-0" 1/ AE-101
WORKSTATION (WS-5)7
1/4" = 1'-0" 1/ AE-101
WORKSTATION (WS-1A)2
1/4" = 1'-0" 1/ AE-101
WORKSTATION (WS-4)6
1/4" = 1'-0" 1/ AE-101
WORKSTATION (WS-1B)3
No. REVISION DESCRIPTION DATE
1. ALL WALLS TO BE PAINTED (PT1), UNLESS NOTED OTHERWISE. REFERNCE THIS SHEET FOR
ROOM FINISH SCHEDULE.
2. ALL COUNTERTOPS TO BE (SS1), UNLESS NOTED OTHERWISE. REFERENCE SHEET AE-301
FOR MILLWORK SECTIONS.
3. ALL RUBBER WALL BASE TO BE (RB1), UNLESS NOTED OTHERWISE. REFERNCE THIS SHEET
FOR ROOM FINISH SCHEDULE.
4. ALL WINDOW SILLS TO BE (SS1), UNLESS NOTED OTHERWISE. REFERNCE SHEET AE-300 FOR
WINDOW SILL DETAIL.
5. REFERENCE SHEET AE-300 FOR DOOR AND WINDOW DETAILS.
6. ASBESTOS OR ASBESTOS CONTAINING PRODUCTS ARE NOT ALLOWED IN ANY ASPECT OF
THIS CONSTRUCTION.
7. COORDINATE ALL DISCIPLINES AND ALL ASPECTS OF WORK. CONFLICTS AND
DISCREPENCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT IMMEDIATELY.
8. PREP FLOOR FOR INSTALLATION OF NEW ACCESS FLOOR AND FLOOR FINISHES AS SHOWN.
CPT1 - CARPET TILE, ASHLAR INSTALLATION PATTERN
PATCRAFT, ARTEFACT, REACT I0513
RENEWED ELEMENT 00500, 12" X 48"
LOOSE LAY INSTALLATION METHOD
CPT2 - CARPET TILE, HERRINGBONE INSTALLATION PATTERN
PATCRAFT, ARTEFACT, REACT I0513
RENEWED ELEMENT 00500, 12" X 48"
LOOSE LAY INSTALLATION METHOD
LVT1 - LUXURY VINYL TILE, ASHLAR INSTALLATION PATTERN
SHAW CONTRACT, CORETEC XRC, CONCRETE
FORGED CONCRETE 03507, 18" X 24"
FLOATING INSTALLATION METHOD
LVT2 - LUXURY VINYL TILE
LIFEPROOF (HOME DEPOT), RIGID CORE LUXURY VINYL TILE FLOORING
SCRATCH STONE, MODEL #: I473106L, INTERNAL SKU: 3000876921
ASHLAR INSTALLATION PATTERN
A
B
D
E
6 7 8 9 10 11 12
BREAK ROOM
200Q
CHIEF
200.15
CHIEF
200.13
CHIEF
200.12
CHIEF
200.02
DEPUTY
200.08
DEPUTY
200.10
CHIEF
200.03
CONFERENCE
200.05
CHIEF
200.14
COLLAB
200.11
DEPUTY
200.09
DEPUTY
200.07
DIRECTOR
200.06
COLLAB
200.04
RECEPTION
200.01
STOR
200.05.1
200.17.2
MANAGEMENT
ANALYST
200.18
OPEN OFFICE B
200.16
OPEN OFFICE A
200.17 C
O R
R
ID
O R
0A
C O
R R
ID
O
R
0B
STAIR 1
NIC
MECHANICAL ROOM
200R
TOILET ROOM
200J
TOILET ROOM
200I
ELEC
200K
IDF
200L
C O
R R
ID
O
R
0D
STOR
200.17.1
STOR
200.16.1
S1 S1 S1 S1 S1 S1 S1 S1
S1
S1
S3
S3
S5
S5
S2
S3 S3
S3
S3
S5
S3
S5
ON DOOR GLAZING
2'-0", CENTERED HORIZONTALLY
CONFERENCE ROOM
CUSTOM VINYL DECAL; MOUNTED ON DOOR GLAZING
AT CONFERENCE AND COLLABORATION ROOMS
VETERAN BENEFITS ADMINISTRATION
Jane Doe
1/
2"
8 1/2"
S2
AT ALL DEPUTY AND CHIEF OFFICE ENTRIES
BASIS OF DESIGN - TAKEFORM FUSION | 04, TYPE H F04B-D1
ROOM NUMBER IN ADA COMPLIANT TACTILE NUMERALS AND BRAILLE
BLACK ADA_FUTURA FONT OR SIMILAR BY MANUFACTURER
LAMINATE FINISH FACE PLATE
SILVER WINGS LAMINATE OR SIMILAR BY MANUFACTURER
METAL ACCENT STRIP
BLACK FINISH OR SIMILAR BY MANUFACTURER
EMPLOYEE NAME PLATE INSERT
TRANSPARENT INSERT BACKGROUND WITH EMPLOYEE NAME
IN BLACK ADA_FUTURA FONT OR SIMILAR BY MANUFACTURER
TAPE AND SILICONE INSTALLATION PER MANUFACTURER
48" AFF MINIMUM TO BOTTOM EDGE…
This is the start of the file's text. The full file is on GovTribe.