This solicitation is for renovation services at the Hines Finance Center located at the Edward Hines Jr. VA Medical Center in Hines, Illinois. The scope of work includes demolishing existing interior walls, ceilings, and access flooring in approximately 7,651 square feet of office and break room space. The renovation will provide new finishes, casework, plumbing fixtures, mechanical and electrical systems. Specific requirements include installing new gypsum board and acoustic ceiling tiles, commercial carpet and luxury vinyl flooring. Mechanical work involves reconfiguring ductwork, relocating existing heat pumps, and adding new diffusers and grilles. For electrical, the project replaces outdated panels and provides new lighting, security cameras, and data cabling. The period of performance is 180 days from notice to proceed. The solicitation is issued by the Department of Veterans Affairs Veteran Benefits Administration for design and construction services.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 23 09 23.27.pdf | ||
| 23 31 13.pdf | ||
| 23 01 30.52.pdf | ||
| 36C10E21R0009 0005.docx | DOCX document | |
| 23 09 93.11.pdf | ||
| 36C10E21R0009 0004.docx | DOCX document | |
| Site Visit Sign In Sheet Page 1_10-19-2021.pdf | ||
| 36C10E21R0009 0003.docx | DOCX document | |
| Site Visit Sign In Sheet Page 2_10-19-2021.pdf | ||
| 36C10E21R0009 0002.docx | DOCX document | |
| 36C10E21R0009 0001.docx | DOCX document | |
| Hines Finance Center - Drawings 6-14-2021.pdf | ||
| Wage Determination for Cook County 9-24-2021.pdf | ||
| 201VB3032 Hines Finance Center - Specifications_6-14-2021.pdf | ||
| 36C10E21R0009.docx | DOCX document |
Show all 15
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Veteran Benefits Administration June 14, 2021
201VB3032 | Hines Finance Center
Specifications – 100% Design
REGISTERS AND GRILLES
23 37 13.23 - Page 1 of 3
SECTION 23 37 13.23
REGISTERS AND GRILLES
PART 1 - GENERAL
1.1 RELATED DOCUMENTS
A. Drawings and general provisions of the Contract, including General and Supplementary
Conditions and Division 01 Specification Sections, apply to this Section.
1.2 SUMMARY
A. Section Includes:
1. Fixed face grilles.
B. Related Requirements:
1. Section 23 33 00 "Air Duct Accessories" for fire and smoke dampers and volume-control dampers not integral to registers and grilles.
2. Section 23 37 13.13 "Air Diffusers" for various types of air diffusers.
3. Section 23 37 13.43 "Security Registers and Grilles" for security registers and security grilles.
4. Section 23 37 16 "Fabric Air-Diffusion Devices" for continuous tubular diffusers.
1.3 ACTION SUBMITTALS
A. Product Data: For each type of product.
1. Data Sheet: Indicate materials of construction, finish, and mounting details; and performance data including throw and drop, static-pressure drop, and noise ratings.
2. Register and Grille Schedule: Indicate drawing designation, room location, quantity, model number, size, and accessories furnished.
B. Samples: For each exposed product and for each color and texture specified. Smallest size register and grille indicated.
C. Samples for Initial Selection: For registers and grilles with factory-applied color finishes.
Smallest size register and grille indicated.
D. Samples for Verification: For registers and grilles, in manufacturer's standard sizes to verify color selected. Smallest size register and grille indicated.
23 37 13.23 - Page 2 of 3
1.4 INFORMATIONAL SUBMITTALS
A. Coordination Drawings: Reflected ceiling plans, drawn to scale, on which the following items are shown and coordinated with each other, using input from installers of the items involved:
1. Ceiling suspension assembly members.
2. Method of attaching hangers to building structure.
3. Size and location of initial access modules for acoustical tile.
4. Ceiling-mounted items including lighting fixtures, diffusers, grilles, speakers, sprinklers, access panels, and special moldings.
5. Duct access panels.
B. Source quality-control reports.
PART 2 - PRODUCTS
2.1 GRILLES
A. Fixed Face Grille
1. Manufacturers: Subject to compliance with requirements, available manufacturers offering products that may be incorporated into the Work include, but are not limited to the following:
a. Hart & Cooley Inc.
b. Price Industries.
c. Titus, a division of Air System Components; Johnson Controls, Inc.
2. Material: Aluminum.
3. Finish: Baked enamel, color selected by Architect.
4. Face Blade Arrangement: Eggcrate; spaced 1/2 inch (13 mm) apart.
5. Face Arrangement: Perforated core.
6. Core Construction: Integral.
7. Frame: 1-1/4 inches (32 mm) wide.
8. Mounting Frame: Filter.
9. Mounting: Countersunk screw.
10. Accessory: Filter.
2.2 SOURCE QUALITY CONTROL
A. Verification of Performance: Rate registers and grilles according to ASHRAE 70, "Method of
Testing for Rating the Performance of Air Outlets and Inlets."
23 37 13.23 - Page 3 of 3
PART 3 - EXECUTION
3.1 EXAMINATION
A. Examine areas where registers and grilles are installed for compliance with requirements for installation tolerances and other conditions affecting performance of equipment.
B. Proceed with installation only after unsatisfactory conditions have been corrected.
3.2 INSTALLATION
A. Install registers and grilles level and plumb.
B. Outlets and Inlets Locations: Drawings indicate general arrangement of ducts, fittings, and accessories. Air outlet and inlet locations have been indicated to achieve design requirements for air volume, noise criteria, airflow pattern, throw, and pressure drop. Make final locations where indicated, as much as practical. For units installed in lay-in ceiling panels, locate units in the center of panel. Where architectural features or other items conflict with installation, notify
Architect for a determination of final location.
C. Install registers and grilles with airtight connections to ducts and to allow service and maintenance of dampers, air extractors, and fire dampers.
3.3 ADJUSTING
A. After installation, adjust registers and grilles to air patterns indicated, or as directed, before starting air balancing.
END OF SECTION 23 37 13.23