H.08 W912HN21B3004 Drawings Vol-3.pdf
PDF 2 MB Posted
- Attached to
- Seymour Johnson Air Force Base-Berkeley Gate Construction Federal contract opportunity
- Solicitation number
- W912HN21B3004
About this file
This set of construction documents includes drawings and specifications for the Berkeley Gate Entry Control Point project at Seymour Johnson Air Force Base in Goldsboro, North Carolina. The project involves demolishing the existing entry control point and constructing a new configuration that meets security requirements. The new construction will include rebuilding roadways with lighting, curbing and sidewalks; installing active vehicle barrier nets and a passive brick veneer knee wall barrier system; constructing a privately operated vehicle search area with shelter; and building an overwatch facility in accordance with security standards. Related specifications designate requirements for doors, windows, glazing, and progressive collapse prevention. The solicitation is for the U.S. Army Corps of Engineers Savannah District to complete the construction work defined in the contract drawings and specifications under solicitation number W912HN21B3004.
View the file
Other files for this federal contract opportunity
Show all 27
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
BARBINA.SEAN.ERIC.1556536194 Digitally signed by BARBINA.SEAN.ERIC.1556536194 Date: 2021.03.26 06:56:06 -04'00'
FUNK.TROY.ALAN.1039429256 Digitally signed by FUNK.TROY.ALAN.1039429256 Date: 2021.03.26 07:18:49 -04'00'
HENDREN.TRACY.LEE.1229932868
2021.03.26 08:41:47 -04'00'
A N
S I
D
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
J
H A
IR
E
J
H A
IR
E
J
M C
T
IE
R N
A N
S
B A
R B
IN
A
M A
R C
H
S E
Y M
O U
R J
O H
N S
O N A
IR
F
O R
C E B
A S
E
N O
R T
H C
A R
O L
IN
A
B E
R K
E L E
Y G
A T
E E
N T
R Y C
O N
T R
O L P
O
IN
T
F Y P
N V
K A
G
V O
L U
M E O
V E
R W
A T
C H F
A C
IL
IT
Y
SHEET ID
READY TO ADVERTISE (RTA)
F
IL
E N
A M
E
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
S O
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
A
M A
R K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
®of Engineers
US Army Corps k6enxjlh
02-MAR-2021 06:00
C:\Users\k6enxjlh\Desktop\Projects\ProjectWise_Projects\Sey0144\05_W912HN-##-#-####\PDF\Volume 3\GI001V3.dgn
C A
T E
G O
R Y C
O D
E
-3
-0
GI001
IN
D
E X O
F D
R A
W
IN
G S
G I0
V .d g n
G-001 COVER SHEET
GI001 INDEX OF DRAWINGS
GI002 GENERAL NOTES, ABBREVIATIONS
S-001 GENERAL STRUCTURAL NOTES
S-002 GENERAL STRUCTURAL NOTES
SB101 FOUNDATION AND SLAB PLAN
SB501 FOUNDATION, SLAB AND CMU DETAILS
SB502 FOUNDATION AND CMU DETAILS
SF101 FLOOR AND ROOF FRAMING PLAN
SF501 FLOOR AND ROOF FRAMING DETAILS
A-101 FIRST FLOOR PLAN & FINISH SCHEDULE
A-102 ROOF PLANS
A-103 OVERWATCH REFLECTED CEILING PLAN
A-201 OVERWATCH ELEVATIONS
A-310 WALL SECTIONS
A-510 ROOF/MISC DETAILS
A-602 DOOR/WINDOW DETAILS
A-800 LIFE SAFETY ANALYSIS/PLAN
F-001 FIRE PROTECTION LEGEND AND GENERAL NOTES
M-001 HVAC LEGEND
MH101 HVAC FLOOR PLAN
MH301 HVAC SECTIONS
MH501 HVAC DETAILS
MH502 HVAC DETAILS
MH503 HVAC DETAILS
MH601 HVAC SCHEDULES
MI801 HVAC CONTROLS LEGEND
MI802 DUCTLESS SPLIT SYSTEM CONTROLS
E-001 LEGEND AND NOTES
EL101 OVERWATCH LIGHTING PLAN
EL501 LIGHT FIXTURE SCHEDULE AND DETAILS
EL601 LIGHTING CONTROL SCHEDULES AND DIAGRAMS
EP101 OVERWATCH POWER PLAN
EP601 POWER ONE-LINE DIAGRAM
EP602 PANEL SCHEDULES
EY101 OVERWATCH SPECIAL SYSTEMS PLAN
EY501 SPECIAL SYSTEMS DETAILS
EG501 GROUNDING DETAILS
T-001 COMMUNICATIONS LEGEND AND GENERAL NOTES
TN101 OVERWATCH TELECOMMUNICATIONS PLAN
TN501 COMMUNICATIONS DETAILS
SHEET ID.
INDEX OF DRAWINGS
D E
S C
R
IP
T
IO
N
W
O G
L E
T H
O R
P E A
V E
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
S A
V A
N N
A H D
IS
T R
IC
T
S A
V A
N N
A H
G A
SHEET ID.
TITLESHEET ID.
TITLETITLE
SHEET LOGICMATERIALS
EARTH
DRAWING ABBREVIATIONS GENERAL NOTES
C (cont) ---------------------
CORR CORRIDOR
CP CONCRETE PIPE
CPT CARPET
CR CONTROL ROOM
CS CAST STONE
CSWK CASEWORK
CT CERAMIC TILE
CTB CERAMIC TILE BASE
CTF CERAMIC TILE FLOOR
CTR CENTER
CU FT CUBIC FEET
CW CASEMENT WINDOW
D ---------------------
D DEPTH
D LABEL CLASS D DOOR
DBL DOUBLE
DEMO DEMOLITION
DEPT DEPARTMENT
DET DETAIL
DF DRINKING FOUNTAIN
DIA DIAMETER
DIR DIRECTION
DIST DISTANCE
DOC DOCUMENT
DR DOOR
DS DOWNSPOUT
E ---------------------
E LABEL CLASS E DOOR
EA EACH
EF EACH FACE
EIFS EXTERIOR INSULATION
AND FINISH SYSTEM
EJ EXPANSION JOINT
ES EACH SIDE
EL ELEVATION
ELEC ELECTRICAL
ELEV ELEVATOR
ENTR ENTRANCE
EPS EXPANDED POLYSTYRENE
EQ EQUAL
EWC ELECTRIC WATER COOLER
EXP EXPOSED, EXPANSION
EXT EXTERIOR, EXTINGUISHER
EXT GR EXTERIOR GRADE
F ---------------------
FA FIRE ALARM
FAAP FIRE ALARM ANNUNCIATOR
PANEL
FAS BD FASCIA BOARD
FCO FLOOR CLEANOUT
FD FLOOR DRAIN
FDTN FOUNDATION
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FED FEDERAL
FF FINISH FLOOR
FFE FINISH FLOOR ELEVATION
FF INSUL FOIL BACKED INSULATION
FGL FIBERGLASS
FH FIRE HOSE
FHP FULL HEIGHT PARTITION
FIN FINISH
FIN BS FINISH BOTH SIDES
FIN FLR FINISH FLOOR
FIN GR FINISH GRADE
FIXT FIXTURE
FLDG FOLDING
FLEX FLEXIBLE
FLG FLOORING
FLMT FLUSH MOUNT
FLR FLOOR
FM FACTORY MUTUAL
FOC FACE OF CONCRETE
FOM FACE OF MASONRY
FR FIRE RESISTANT
FRG FIBER REINFORCED GYPSUM
FRMG FRAMING
FRP FIBERGLASS REINFORCED
PLASTIC
FRTW FIRE RETARDANT TREATED
WOOD
FS FEDERAL SPECIFICATION
FSTNR FASTENER
FT FEET
FTG FOOTING
FWC FABRIC WALLCOVERING
G ---------------------
G NATURAL GAS
GALV GALVANIZED
GB GRAB BAR
GEJ GUTTER EXPANSION JOINT
G (cont) ---------------------
GFCI GOVERNMENT FURNISHED
CONTRACTOR INSTALLED
GFGI GOVERNMENT FURNISHED
GOVERNMENT INSTALLED
GFRG GLASS-FIBER-REINFORCED
GYPSUM
GLZ GLAZING
GR FL GROUND FLOOR
GUT GUTTER
GWB GYPSUM WALL BOARD
GYP BD GYPSUM BOARD
GYP PLAS GYPSUM PLASTER
H ---------------------
HB HOSE BIBB
HC HANDICAPPED
HDPE HIGH DENSITY POLYETHYLENE
HDW HARDWARE
HDWD HARDWOOD
HEPA HIGH EFFICIENCY PARTICULATE
AIR (FILTER)
HM HOLLOW METAL
HMD HOLLOW METAL DOOR
HORIZ HORIZONTAL
HR HOUR
HT HEIGHT
HYDR HYDRAULIC
I ---------------------
IBC INTERNATIONAL BUILDING
CODE
INSUL INSULATION
INT INTERIOR
ILO IN LIEU OF
J ---------------------
JAN JANITOR
JT JOINT
K ---------------------
KPD KEYPAD
KIT KITCHEN
KPL KICKPLATE
L ---------------------
LAM LAMINATE
LAV LAVATORY
LBR LUMBER
LBS POUND
LDG LANDING
LF LINEAR FEET (FOOT)
LG LIGHT GAUGE
LIB LIBRARY
LIN LINEAR
LKR LOCKER
LOC LOCATION
LT LIGHT
LVDR LOUVER DOOR
LVR LOUVER
M ---------------------
MACH RM MACHINE ROOM
MATL MATERIAL
MAX MAXIMUM
MC MOISTURE CONTENT
MD METAL DECK
MECH MECHANICAL
MECH RM MECHANICAL ROOM
MEMB MEMBRANE
MF MILL FINISH
MFR MANUFACTURER
MID MIDDLE
MIN MINIMUM, MINUTE
MIRR MIRROR
MISC MISCELLANEOUS
MLDG MOLDING (MOULDING)
MO MASONRY OPENING
MOD MODIFY
MB MOISTURE BARRIER
MTD MOUNTED
MTG MOUNTING
MTL METAL
MVBL MOVABLE
MWP MEMBRANE WATERPROOFING
N ---------------------
N NORTH
NA NOT APPLICABLE
NFPA NATIONAL FIRE PROTECTION
ASSOCIATION
NIC NOT IN CONTRACT
NO NUMBER
N (cont) ---------------------
NOM NOMINAL
NP NO PAINT
NRC NOISE REDUCTION COEFFICIENT
NTS NOT TO SCALE
O -------------------
OA OVERALL
OC ON CENTER
OD OUTSIDE DIAMETER
OFD OVERFLOW DRAIN
OFF OFFICE
OGL OBSCURE GLASS
OPH OPPOSITE HAND
OPNG OPENING
OPP OPPOSITE
OPQ OPAQUE
OWSJ OPEN WEB STEEL JOIST
OPR OPERABLE
ORD OVERFLOW ROOF DRAIN
ORIG ORIGINAL
P --------------------
PA PUBLIC ADDRESS
PAR PARAPET
PAT PATTERN
PB PULL BOX
PBD PARTICLEBOARD
PCC PRECAST CONCRETE
PCF POUNDS PER CUBIC FOOT
PCT PERCENT
PERF PERFORATED
PERIM PERIMETER
PH PHASE
PIL PILASTER
PL PROPERTY LINE
PL GL PLATE GLASS
PLAM PLASTIC LAMINATE
PLAS PLASTER
PLBG PLUMBING
PLG PILING
PLYWD PLYWOOD
PNL PANEL
PP PL PUSH/PULL PLATE
PR PAIR
PRCST PRECAST
PREFIN PREFINISHED
PRKG PARKING
PS CONC PRESTRESSED CONCRETE
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PT PRESSURE TREATED
PTD PAPER TOWEL DISPENSER
PTDR PAPER TOWEL DISPENSER
AND RECEPTACLE
PTN PARTITION
PWR POWER
Q --------------------
QT QUARRY TILE
QTY QUANTITY
R --------------------
RB RESILIENT BASE
RBM REINFORCED BRICK MASONRY
RBR RUBBER
RC REINFORCED CONCRETE
RCP REFLECTED CEILING PLAN
RD ROOF DRAIN
RDG INS RIGID INSULATION, SOLID
REC RECESSED
REF REFERENCE
REM REMOVABLE
REP REPAIR
REPL REPLACE
REQ REQUIRE
REQD REQUIRED
RESIL RESILIENT
REST RESTROOM
RF RESILIENT FLOORING
RFG ROOFING
RH ROOF HATCH
RHR RIGHT HAND REVERSE
RL ROOF LEADER
RLG RAILING
RM ROOM
RO ROUGH OPENING
RSD ROLLING STEEL DOOR
RV ROOF VENT
RVL REVEAL
S --------------------
SB SPLASH BLOCK
SCHED SCHEDULE
SD SMOKE DETECTOR
S (cont) --------------------
SF SQUARE FOOT (FEET)
SFTWD SOFTWOOD
SGL SINGLE
SHT MTL SHEET METAL
FLASH (FLASHING)
SHTHG SHEATHING
SHV SHELVING
SIM SIMILAR
SJ SCORED JOINT
SKLT SKYLIGHT
SLNT SEALANT
SMK SMOKE
SMLS SEAMLESS
SP EL SPOT ELEVATION
SPEC SPECIFICATION
SQ SQUARE
SQ IN SQUARE INCH
SQ YD SQUARE YARD
SS STAINLESS STEEL
SSMR STANDING SEAM METAL ROOF
ST STAIRS
STC SOUND TRANSMISSION
COEFFICIENT
STD STANDARD
STL STEEL
STL JST STEEL JOIST
STL RF DK STEEL ROOF DECK
STOR STORAGE
STR STRINGERS
STRB/HRN STROBE/HORN
STRUC STRUCTURAL
SUB FL SUBFLOOR
SUSP SUSPENDED
SV SHEET VINYL
SW SIDEWALK
T --------------------
T TREAD
T/S TUB/SHOWER
TD TRENCH DRAIN
TEL TELEPHONE
TEMP TEMPORARY
TER TERRAZZO
TFF TOP OF FINISH FLOOR
TH THICK
THK THICKNESS
TK BD TACKBOARD
TMPD GL TEMPERED GLASS
TN TRUE NORTH
TOF TOP OF FOOTING
TOM TOP OF MASONRY
TOP TOP OF PARAPET
TOPO TOPOGRAPHY
TOS TOP OF SLAB
TRANS TRANSOM
TRTD TREATED
TV TELEVISION
TYP TYPICAL
U --------------------
UG UNDERGROUND
UH UNIT HEATER
UL UNDERWRITER
LABORATORIES
UNO UNLESS NOTED OTHERWISE
UPS UNINTERRUPTIBLE POWER
SYSTEM
V --------------------
VAV VARIABLE AIR VOLUME/UNIT
VCT VINYL COMPOSITION TILE
VERT VERTICAL
VEST VESTIBULE
VTR VENT THRU ROOF
W --------------------
W/ WITH
WC WATER CLOSET
WD WOOD
WDW WINDOW
W/O WITHOUT
WWF WELDED WIRE FABRIC
X --------------------
XFMR TRANSFORMER
A ---------------------
A LABEL CLASS A DOOR
A/C AIR CONDITION
A/C UNIT AIR CONDITIONING UNIT
A/E ARCHITECT/ENGINEER
AB ANCHOR BOLT
ABV ABOVE
ACC ACCESSIBLE
ACS AUTOMATIC CONTROL SYSTEM
ACS DR ACCESS DOOR
ACS PNL ACCESS PANEL
ACT ACOUSTICAL CEILING TILE
ADA AMERICANS WITH
DIDISABILITIES ACT
ADJ ADJACENT
ADMIN ADMINISTRATION
AFC ABOVE FINISHED COUNTER
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
AFS ABOVE FINISHED SLAB
AGGR AGGREGATE
AHU AIR HANDLING UNIT
AIB AIR INFILTRATION BARRIER
ALT ALTERNATE
ALUM ALUMINUM
ANOD ANODIZE
APPROX APPROXIMATE
AR AS REQUIRED
ARCH ARCHITECT
ASC ABOVE SUSPENDED CEILING
ASSY ASSEMBLY
ATC ACOUSTICAL TILE CEILING
AVG AVERAGE
AWT ACOUSTICAL WALL TREATMENT
B ---------------------
B LABEL CLASS B DOOR
BALC BALCONY
BD BOARD
BDRY BOUNDARY
BEJ BRICK EXPANSION JOINT
BFF BELOW FINISH FLOOR
BHMA BUILDER'S HARDWARE
MANUFACTURER'S
ASSOCIATION
BLDG BUILDING
BLKG BLOCKING
BLT IN BUILT-IN
BN BULLNOSE
BOS BOTTOM OF STEEL
BOT BOTTOM
BRG BEARING
BRKT BRACKET
BSMT BASEMENT
BTWN BETWEEN
BUR BUILT-UP ROOFING
C ---------------------
C LABEL CLASS C DOOR
CAB CABINET
CATW CATWALK
CAV CAVITY
CBB CEMENTITIOUS (BACKER)
BOARD
CD CONSTRUCTION DOCUMENTS
CDW CHILLED DRINKING WATER
CEM PLAS CEMENT PLASTER
CER CERAMIC
CF CONTRACTOR FURNISHED
CFCI CONTRACTOR FURNISHED/
CONTRACTOR INSTALLED
CFE CONTRACTOR FURNISHED
EQUIPMENT
CFM CUBIC FEET PER MINUTE
CFMF COLD-FORMED METAL FRAMING
CFS CUBIC FEET PER SECOND
CG CORNER GUARD
CI CAST IRON
CIP CAST-IN-PLACE
CJ CONTROL JOINT
CL CENTER LINE
CLG CEILING
CLG DIFF CEILING DIFFUSER
CLG HT CEILING HEIGHT
CLL COLUMN LINE
CLO CLOSET
CLR COLOR
CMU CONCRETE MASONRY UNIT
CNDS CONDENSATE
CDR CARD READER
CO CLEANOUT
COL COLUMN
COMM COMMUNICATION
CONC CONCRETE
CONC FLR CONCRETE FLOOR
CONF CONFERENCE
CONT CONTINUE, CONTINUOUS
COORD COORDINATE
0 GRID/COLUMN
LINE DESIGNATOR
INTERIOR ELEVATION
SECTION
ROOM
NAME/NUMBER
REVISION
TAG
PLAN, BLOW-UP
DETAIL
PLAN NORTH
NORTH ARROW
W/ TRUE NORTH
INDICATION
SPOT ELEVATION
Name Elevation REFERENCE LEVEL
PLATE NUMBER WHERE
SECTION/DETAIL IS
DRAWN
PLATE NUMBER WHERE
SECTION/DETAIL IS DRAWN
PLATE NUMBER WHERE
SECTION/DETAIL IS
DRAWN
A-101
SIM
EXTERIOR ELEVATION
PLATE NUMBER WHERE
SECTION/DETAIL IS
DRAWN
A-101
SYMBOLS
INTERIOR ELEVATION SYMBOL
EXTERIOR ELEVATION SYMBOL
SECTION SYMBOL
CALLOUT SYMBOL
ELEVATION SYMBOL
LEVEL SYMBOL
GENERAL SYMBOLS
Room name
Room name
150 SF
ROOM
NAME/NUMBER
W/ AREA
CENTERLINE
INDICATOR
1/2 1 21
SCALE: 1"=1'-0"
SCALE BAR
View Name1
MATCHLINE INDICATOR
VIEW TITLE BAR
1 / A-101
1 / A-102
REFERENCE
SHEETS
SAND
CONCRETE/ PRECAST
CONCRETE
STONE
BRICK
CMU
PLYWOOD
RIGID INSULATION
BATT INSULATION
GYPSUM BOARD,
PLASTER
EIFS
1. THESE LEGENDS ARE COMPOSED OF STANDARD SYMBOLS AND ARE PERTINENT TO THE CONDITIONS
ON THIS SET OF DRAWINGS TO THE EXTENT APPLICABLE.
2. ADDITIONAL LEGENDS AND/OR ABBREVIATIONS MAY APPEAR IN THIS SET OF DRAWINGS TO INDICATE
SPECIFIC CONDITIONS IN LIEU OF SYMBOLS SHOWN ON THIS SHEET.
A-101
SIM
A101
Ref
R ef
Ref
R ef
AE201
DISCIPLINE*:
G - GENERAL
C - CIVIL
L - LANDSCAPE
S - STRUCTURAL
A - ARCHITECTURE
DISCIPLINE DESIGNATOR
SHEET TYPE
DESIGNATOR
SHEET SEQUENCE
NUMBER
F- FIRE PROTECTION
P - PLUMBING
M - MECHANICAL
E - ELECTRICAL
T-
TELECOMMUNICATIONS
*ADDITIONAL DISCIPLINES MAY BE USED
IN THIS DRAWING SET.
DRAWING NAMING CONVENTION
SHEET ID
SHEET ID
D R
AW
N
B Y:
D
ES
IG
N
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
FI
LE
N
AM
E:
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
C H
EC
KE
D B
Y:
US Army Corps of Engineers ®
D
C
B
A
C
AT
EG
O
R Y
C O
D E:
AN
SI
D
E
F
G
2 3 4 5 6 7 8 9 10
M
AR
C H
W
2H N
-2 1-
B-
J.
H
AI
R
E
J.
H
AI
R
E
S.
B
AR
BI
N A
2-
0-
GI002
G
EN
ER
AL
N O
TE
S, A
BB
R
EV
IA
TI
O N
S
SA
VA
N N
AH
D
IS
TR
IC
T
W . O
G
LE
TH
O
R
PE
A
VE
SA
VA
N
N
AH
, G A
SE
YM
O U
R J
O H
N
SO
N A
IR
F
O R
C E
BA
SE
, N O
R
TH
C
AR
O
LI
N A
BE
R
KE
LE
Y G
AT
E
EN
TR
Y C
O N
TR
O
L
PO
IN
T
PO
IN
T
FY
, P
N V
KA
G
VO
LU
M E
-O
VE
R
W
AT
C H
F
AC
IL
IT
Y
J.
M
C
TI
ER
N
AN
READY TO ADVERTISE (RTA)
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
DESIGN CODE NOTES:
1. STRUCTURAL DESIGN IS IN ACCORDANCE WITH THE FOLLOWING CODES AND SPECIFICATIONS:
A. IBC 2018, INTERNATIONAL BUILDING CODE
B. ASCE 7-16, MINIMUM DESIGN LOADS FOR BUILDINGS AND STRUCTURES
C. ACI 318-14, BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE
D. ACI 360R-10, DESIGN OF SLABS ON GRADE
E. TMS 402-16, BUILDING CODE REQUIREMENTS FOR MASONRY STRUCTURES
F. AISC 360-16, SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS
G. AISI S100-15, NORTH AMERICAN SPECIFICATION FOR THE DESIGN OF COLD FORMED STEEL
STRUCTURAL MEMBERS
H. SDI, STEEL DECK INSTITUTE: DESIGN MANUAL FOR COMPOSITE DECK, FORM DECK,
& ROOF DECK
I. UFC 1-200-01, GENERAL BUILDING REQUIREMENTS, (8 OCT 2019)
J. UFC 3-301-01, STRUCTURAL ENGINEERING, (1 OCT 2019)
K. UFC 4-010-01, DOD MINIMUM ANTITERRORISM STANDARDS FOR BUILDINGS,
(12 DEC 2018)
DESIGN LOAD CRITERIA:
1. LIVE LOADS:
UNO, SLAB ON GRADE 150 PSF
UNO, ELEVATED SLABS 75 PSF
PARTITIONS NOT APPLICABLE
2. ROOF LIVE LOAD: 20 PSF (REDUCIBLE)
3. SNOW LOADS:
RISK CATEGORY II
SNOW IMPORTANCE FACTOR, Is 1.0 MINIMUM GROUND SNOW LOAD, Pg 10 PSF SNOW EXPOSURE FACTOR, Ce 0.9 SNOW THERMAL FACTOR, Ct 1.2 ROOF SLOPE FACTOR, Cs 1.0
FROST PENETRATION DEPTH 0 IN
BALANCED SNOW LOADING:
MINIMUM LOW SLOPE ROOF SNOW LOAD, Pm 10 PSF
UNBALANCED SNOW LOADING: DOES NOT CONTROL OVER ROOF LIVE LOAD
SNOW DRIFT LOADING: DOES NOT CONTROL OVER ROOF LIVE LOAD
4. WIND LOADS:
RISK CATEGORY II
WIND IMPORTANCE FACTOR, Iw 1.0
BASIC WIND SPEED, V 123 MPH
WIND EXPOSURE CATEGORY C
GUST EFFECT FACTOR, G 0.85
INTERNAL PRESSURE COEFFICIENTS, GCpi +/- 0.18
5. COMPONENTS AND CLADDING WIND PRESSURES: SEE S-002
6. SEISMIC LOADS:
RISK CATEGORY II
SEISMIC IMPORTANCE FACTOR, Ie 1.0 MAPPED SPECTRAL RESPONSE ACCELERATION, Ss 0.113
MAPPED SPECTRAL RESPONSE ACCELERATION, S1 0.055
SITE CLASS D
DESIGN SPECTRAL RESPONSE ACCELERATION, Sds 0.12 DESIGN SPECTRAL RESPONSE ACCELERATION, Sd1 0.09
SEISMIC DESIGN CATEGORY B
SEISMIC ANALYSIS PROCEDURE EQUIVALENT LATERAL FORCE
SEISMIC-FORCE RESISTING SYSTEM ORDINARY REINFORCED MASONRY SHEAR WALLS
RESPONSE MODIFICATION FACTOR, R 2
SYSTEM OVERSTRENGTH FACTOR 2.5
DEFLECTION AMPLIFICATION FACTOR, Cd 2 SEISMIC RESPONSE COEFFICIENT, Cs 0.06
SEISMIC DESIGN BASE SHEAR, V 0.06W
7. ANTI-TERRORISM/FORCE PROTECTION CRITERIA:
NEW BUILDING LOCATION N/A
BUILDING CATEGORY NON-INHABITED BUILDING
DESIGN LEVEL OF PROTECTION (LOP) N/A
CONVENTIONAL CONSTR STANDOFF DISTANCE N/A
APPLICABLE EXPLOSIVE WEIGHT CLASS II
STEEL DOORS AND FRAMES SPEC 08 11 13
ALUMINUM DOORS AND FRAMES SPEC 08 11 16
ALUMINUM WINDOWS SPEC 08 51 13
GLAZING SPEC 08 81 00
PROGRESSIVE COLLAPSE CRITERIA APPLIES N/A (<3 STORIES)
CONCRETE CONSTRUCTION NOTES:
1. ALL CONCRETE CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE PROVISIONS OF THE "BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE" (ACI 318-14) AND THE SPECIFICATIONS FOR
STRUCTURAL CONCRETE (ACI 301-16) OF THE AMERICAN CONCRETE INSTITUTE (ACI).
2. ALL CAST-IN-PLACE CONCRETE SHALL ATTAIN MINIMUM 28-DAY COMPRESSIVE STRENGTH (f'c) OF 4000 PSI AND UTILIZE MAXIMUM WATER-CEMENTITIOUS MATERIAL RATIO (w/cm) OF 0.45. ALL CONCRETE EXPOSED TO WEATHER SHALL BE AIR ENTRAINED. SEE SPECIFICATIONS FOR AIR ENTRAINMENT
REQUIREMENTS.
3. CONCRETE DENSITY SHALL BE NORMAL WEIGHT WITH A DENSITY OF 140 PCF TO 150 PCF UNLESS
NOTED OTHERWISE ON PLANS.
4. ALL CONCRETE SHALL BE NORMAL WEIGHT WITH A DENSITY OF 140 PCF TO 150 PCF.
5. CONCRETE SLAB ON GRADE JOINTS INDICATED ARE DIAGRAMMATIC AND DO NOT REPRESENT ALL OF
THE JOINTS REQUIRED FOR SLAB-ON-GRADE CONSTRUCTION.
6. CONTRACTOR SHALL PROVIDE JOINTS AT ALL RE-ENTRANT CORNERS INCLUDING, BUT NOT LIMITED TO, PIERS AND COLUMNS (AS SHOWN IN TYPICAL COLUMN ISOLATION JOINT), SLAB RECESSES, AND
CORNERS AND ENDS OF WALLS.
7. CONCRETE REINFORCING STEEL SHALL BE DEFORMED BARS CONFORMING TO ASTM A615/A615M, GRADE 60 AND SHALL HAVE FABRICATION TOLERANCES IN ACCORDANCE WITH ACI 315. SHOP
FABRICATE REINFORCING BARS WHICH ARE INDICATED TO BE BENT OR HOOKED.
8. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A185 OR ASTM A497. PROVIDE SHEET-TYPE WELDED
WIRE FABRIC. SHEET LAPS SHALL BE TIED AND LAPPED ONE FULL MESH SPACING PLUS 2".
9. CONCRETE REINFORCING STEEL SHALL BE CONTINUOUS UNLESS OTHERWISE INDICATED.
CONTINUOUS REINFORCING STEEL SHALL BE LAPPED IN ACCORDANCE WITH THE REQUIREMENTS OF ACI 318. REINFORCING STEEL SHALL BE PLACED SO THAT SPACING IS GREATER THAN OR EQUAL TO 2X
BAR DIAMETER.
10. MINIMUM CONCRETE COVER FOR REINFORCING STEEL SHALL BE AS INDICATED. IN NO CASE SHALL
REINFORCEMENT COVER BE LESS THAN THE REQUIREMENTS OF ACI 301.
A. CONCRETE DEPOSITED AGAINST THE GROUND 3"
B. CONCRETE EXPOSED TO EARTH OR WEATHER 2"
C. BEAM AND COLUMNS 1.5"
D. SLABS AND WALLS (NOT EXPOSED TO EARTH OR WEATHER) 1"
11. CONCRETE REINFORCING STEEL MARKED STANDARD HOOK SHALL HAVE A 90° HOOK A MINIMUM OF 12 BAR DIAMETERS IN LENGTH, UNLESS OTHERWISE NOTED. STIRRUPS, TIES, AND 180° HOOKS SHALL
CONFORM TO THE REQUIREMENTS OF ACI 318.
12. PROVIDE 1/2" THICK PRE-MOLDED JOINT FILLER MATERIAL WHERE SOG ABUT VERTICAL SURFACES.
13. ALL EMBEDDED ITEMS SHALL BE PROPERLY PLACED, ACCURATELY POSITIONED AND MAINTAINED
SECURELY IN PLACE PRIOR TO AND DURING CONCRETE PLACEMENT.
14. REINFORCING STEEL SHALL BE SPREAD AT SLEEVES, ANCHORS, RECESSES AND OTHER EMBEDDED
ITEMS UNLESS OTHERWISE INDICATED. REINFORCEMENT SHALL NOT BE CUT TO FACILITATE
PLACEMENT OF EMBEDDED ITEMS, UNLESS INDICATED.
15. NO CONCRETE SHALL BE PLACED UNTIL THE OWNER OR THE CONTRACTING OFFICER'S DESIGNATED
REPRESENTATIVE HAS INSPECTED ALL EMBEDDED WORK, INCLUDING REINFORCEMENT.
16. ALL EXPOSED CONCRETE EDGES SHALL BE CHAMFERED 3/4" OR AS INDICATED.
17. ALUMINUM SHALL NOT BE PLACED IN DIRECT CONTACT WITH CONCRETE UNLESS EFFECTIVELY
COATED OR COVERED TO PREVENT ALUMINUM-CONCRETE REACTION AND ELECTROLYTIC ACTION
BETWEEN ALUMINUM AND STEEL.
18. CONCRETE SLAB ON GRADE JOINTS INDICATED ARE DIAGRAMMATIC AND DO NOT REPRESENT ALL OF THE JOINTS REQUIRED FOR SLAB-ON-GRADE CONSTRUCTION. SLAB PANELS BETWEEN JOINTS SHALL BE SQUARE OR NEARLY SO AND SHALL NOT EXCEED AN ASPECT RATIO WITH PANEL LENGTH GREATER THAN 1.5 TIMES THE PANEL WIDTH. MAXIMUM JOINT SPACING SHALL BE 15 FT UNLESS NOTED
OTHERWISE.
19. CONTRACTOR SHALL PROVIDE JOINTS AT ALL RE-ENTRANT CORNERS INCLUDING, BUT NOT LIMITED
TO, COLUMNS AND SLAB RECESSES.
20. IN ADDITION, CONTRACTOR SHALL COORDINATE SLAB ON GRADE JOINT REQUIREMENTS WITH SLAB-
ON-GRADE CONSTRUCTION SEQUENCING. CONTRACTOR SHALL SHOW JOINT LAYOUT ON
REINFORCING SHOP DRAWING SUBMITTAL FOR APPROVAL.
21. REFER TO CONCRETE SPECIFICATIONS FOR HOT OR COLD WEATHER CONSTRUCTION PROCEDURES.
FOUNDATION AND SLAB NOTES:
1. FOUNDATIONS FOR THIS PROJECT HAVE BEEN DESIGNED IN ACCORDANCE WITH THE
RECOMMENDATIONS IN THE GEOTECHNICAL REPORT PREPARED BY THE SAVANNAH DISTRICT TITLED "BERKELEY GATE ENTRY CONTROL POINT, SEYMOUR JOHNSON AIR FORCE BASE, GOLDSBORO, NORTH
CAROLINA, WAYNE COUNTY, DATED AUGUST 2020.
2. FOUNDATIONS HAVE BEEN DESIGNED TO BEAR ON SOIL CAPABLE OF SUPPORTING AN ALLOWABLE
BEARING PRESSURE OF 1250 PSF.
3. THE CONTRACTOR SHALL HIRE AN INDEPENDENT TESTING LABORATORY AND GEOTECHNICAL
ENGINEER, REGISTERED AND LICENSED IN THE STATE WHERE THE WORK WILL BE ACCOMPLISHED, TO VERIFY THAT ALL OF THE REQUIREMENTS CONTAINED IN SPECIFICATION 31 00 00, EARTHWORK, HAVE
BEEN FOLLOWED AND ACCOMPLISHED.
4. CONTRACTOR SHALL BE PREPARED FOR AND SHALL INCLUDE COST OF FORMING FOUNDATIONS
SHOULD THE EARTH NOT PROVIDE ADEQUATE BANK STABILITY.
5. ALL EXCAVATIONS SHALL BE PERFORMED SO THAT THE SITE AND THE AREA IMMEDIATELY
SURROUNDING THE SITE WHICH AFFECTS CONSTRUCTION OPERATIONS WILL BE CONTINUALLY AND
EFFECTIVELY DRAINED. THE CONTRACTOR SHALL PROVIDE DRAINAGE AND DEWATERING AS
REQUIRED TO ENSURE THAT ALL FOOTING EXCAVATIONS ARE ACCOMPLISHED WITH THE SUBGRADE SOILS REMAINING DRY AND FIRM UNTIL AFTER FOOTINGS ARE PLACED AND BACKFILLED. REMOVAL OF
SURFACE WATER, GROUNDWATER, AND ANY PERCHED WATER CONDITIONS WHICH MIGHT BE
ENCOUNTERED DURING EXCAVATIONS, SHALL BE ACCOMPLISHED BY APPROVED MEANS. REFER TO SPECIFICATION SECTION 31 00 00, EARTHWORK FOR ADDITIONAL EXCAVATION REQUIREMENTS.
6. PLACE FOUNDATION CONCRETE THE SAME DAY EXCAVATIONS ARE MADE OR AS SOON AS PRACTICAL
THEREAFTER.
7. DO NOT PLACE FOUNDATION CONCRETE ON FROZEN OR SATURATED SUBGRADES.
8. DO NOT BEGIN EXCAVATION OPERATIONS OR INSTALL FOUNDATIONS UNTIL FOUNDATION WORK HAS
BEEN COORDINATED WITH ADJACENT UNDERGROUND UTILITIES OR OTHER SUBSURFACE
STRUCTURES WITHIN THE AREA TO BE EXCAVATED.
9. ENSURE THAT EARTH-FORMED FOOTINGS CONFORM TO THE SHAPE, LINES, AND THICKNESSES INDICATED ON THE FOUNDATION PLAN, SECTIONS, AND FOOTING SCHEDULES. EXCAVATION WIDTHS
SHALL BE A MINIMUM OF 4" GREATER THAN DIMENSIONS INDICATED.
10. PLACE 10 MIL VAPOR RETARDER ON TOP OF GRADE IN THE CRAWLSPACE OF THE BUILDING.
11. FOOTINGS SHALL BE LOWERED AS REQUIRED TO PASS UNDER UTILITY LINES. STEP CONTINUOUS
FOOTINGS DOWN AS SHOWN IN THE "TYPICAL STEPPED FOOTING DETAIL" ON SHEET SB502.
12. DRAINAGE AND DEWATERING: ALL EXCAVATION SHALL BE PERFORMED SO THAT THE SITE AND THE AREA IMMEDIATELY SURROUNDING THE SITE WHICH AFFECTS CONSTRUCTION OPERATIONS WILL BE
CONTINUALLY AND EFFECTIVELY DRAINED. THE CONTRACTOR SHALL PROVIDE DRAINAGE AND
DEWATERING AS REQUIRED TO ENSURE THAT ALL FOOTING EXCAVATIONS ARE ACCOMPLISHED WITH
THE SUBGRADE SOILS REMAINING DRY AND FIRM UNTIL AFTER FOOTINGS ARE PLACED AND
BACKFILLED. REMOVAL OF SURFACE WATER, GROUNDWATER, AND ANY PERCHED-WATER
CONDITIONS, WHICH MIGHT BE ENCOUNTERED DURING EXCAVATIONS SHALL BE ACCOMPLISHED BY APPROVED MEANS. REFER TO SPECIFICATION 31 00 00 EARTHWORK FOR ADDITIONAL REQUIREMENTS.
GENERAL NOTES:
1. THIS STRUCTURE IS DESIGNED TO BE SELF-SUPPORTING AND STABLE AFTER ALL BUILDING CONSTRUCTION IS COMPLETE. IT IS THE CONTRACTOR'S RESPONSIBILITY TO DETERMINE ERECTION PROCEDURES AND SEQUENCES TO ENSURE SAFETY OF THE BUILDING AND ITS COMPONENTS DURING ERECTION. THIS INCLUDES THE ADDITION OF NECESSARY SHORING, SHEETING, TEMPORARY BRACING, GUYS, OR TIE-DOWNS.
2. THE CONTRACT DOCUMENTS DO NOT INDICATE THE MEANS AND METHODS OF CONSTRUCTION. THE CONTRACTOR SHALL SUPERVISE AND DIRECT THE WORK DURING ERECTION AND CONSTRUCTION AND
SHALL BE SOLELY RESPONSIBLE FOR ALL CONSTRUCTION MEANS, METHODS, PROCEDURES,
TECHNIQUES, SEQUENCES, AND SAFETY.
3. USE STRUCTURAL DRAWINGS IN CONJUNCTION WITH ALL OTHER DRAWINGS AND SPECIFICATIONS.
COORDINATE THE WORK OF OTHER TRADES INCLUDING, BUT NOT LIMITED TO, THE REQUIREMENTS
FOR SLEEVES, INSERTS, HOLES, HANGERS, AND ANCHORS.
4. REPORT DISCREPANCIES IN DIMENSIONS BETWEEN DIFFERENT DRAWINGS TO THE CONTRACTING
OFFICER PRIOR TO BEGINNING WORK IN IMPACTED AREAS.
5. DETAILS TITLED OR NOTED AS "TYPICAL" APPLY NOT ONLY WHERE SPECIFICALLY INDICATED OR
REFERENCED, BUT ALSO IN ALL OTHER CASES WHERE THE NATURE OF THE CONSTRUCTION
REQUIRES THEIR USE. DETERMINE APPLICABILITY OF TYPICAL DETAILS FROM DESCRIPTIVE TITLES OR FROM THE SIMILARITY OF A CONSTRUCTION CONDITION TO ANOTHER CONDITION WHERE THE DETAIL
IS SPECIFICALLY INDICATED OR REFERENCED.
6. ELEVATIONS ON THE STRUCTURAL DRAWINGS ARE DENOTED AS [±X'-X"] REFERENCED TO THE FINISHED FIRST FLOOR ELEVATION DATUM [0'-0"]. SEE CIVIL DRAWINGS FOR ACTUAL DATUM
ELEVATION.
7. REPRODUCTION OF CONTRACT DRAWINGS SHALL NOT BE USED AS SHOP DRAWINGS UNDER ANY
CIRCUMSTANCE.
STEEL CONSTRUCTION NOTES:
1. FABRICATION AND ERECTION OF STRUCTURAL STEEL AND DESIGN OF CONNECTIONS SHALL BE IN ACCORDANCE WITH AISC 360-16, "SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS" DATED JULY 7, 2016 AND AISC 303-16, "CODE OF STANDARD PRACTICE FOR BUILDING AND BRIDGES" DATED JUNE 15, 2016. THE STRUCTURAL STEEL MEMBERS SHOWN IN THESE DRAWINGS HAVE BEEN ANALYZED AND
DESIGNED USING AISC 360-16 LRFD METHOD.
2. UNLESS OTHERWISE NOTED, STRUCTURAL STEEL SHALL BE IN ACCORDANCE WITH THE ABOVE-LISTED
AISC SPECIFICATION AND THE FOLLOWING:
A. WIDE FLANGE SHAPES (50 KSI) ASTM A992
B. HSS HOLLOW SHAPES (46 KSI) ASTM A500, GRADE B
C. PLATES AND ANGLES ASTM A36
D. HIGH STRENGTH BOLTS ASTM A325
E. ANCHOR RODS W/ NUT AND WASHER ASTM F1554, GRADE 36
3. IT IS THE INTENTION OF THESE DESIGN DOCUMENTS TO DELEGATE THE DESIGN OF ALL STRUCTURAL STEEL CONNECTIONS TO A QUALIFIED REGISTERED ENGINEER. SIGNED AND SEALED CALCULATIONS FOR CONNECTION DESIGNS SHALL BE SUBMITTED SIMULTANEOUSLY WITH FABRICATION DRAWINGS
FOR REVIEW. UNLESS NOTED OTHERWISE ON PLANS, ALL SHEAR CONNECTIONS FOR SIMPLY
SUPPORTED BEAMS SHALL BE DESIGNED TO DEVELOP THE REACTION OF THE MAXIMUM ALLOWABLE
UNIFORM LOAD CAPACITY FOR THE BEAM SIZE AND SPAN SHOWN, ASSUMING FULL LATERAL
SUPPORT, AS TABULATED IN THE ALLOWABLE UNIFORM LOAD TABLES OF THE AISC MANUAL, 15TH
EDITION.
4. ALL SHOP AND FIELD WELDING SHALL BE BY CERTIFIED WELDERS AND SHALL CONFORM TO AWS
STANDARDS. USE E70XX ELECTRODES UNLESS OTHERWISE NOTED. MINIMUM WELD SIZE FOR
STRUCTURAL STEEL IS 3/16" FILLET, UNLESS OTHERWISE NOTED ON PLANS. CURRENT AWS
CERTIFICATIONS SHALL BE AVAILABLE AT THE JOB SITE FOR REVIEW BY THE OWNERS'
REPRESENTATIVE.
5. ALL BOLTED CONNECTIONS, UNLESS OTHERWISE NOTED, SHALL USE 3/4" DIAMETER HIGH STRENGTH BOLTS WITH HARDENED CARBON STEEL WASHERS AS REQUIRED FOR THE CONNECTION LOADS. IF LOADS ARE NOT INDICATED ON THE DRAWINGS, STEEL FABRICATOR SHALL SIZE CONNECTIONS FOR A MINIMUM OF ONE HALF OF THE UNIFORM LOAD CAPACITY OF THE BEAM AS INDICATED IN THE AISC
MANUAL. BEAM CONNECTIONS SHALL CONSIST OF ALL-BOLTED DOUBLE-ANGLE CONNECTIONS
UNLESS NOTED OTHERWISE. SHEAR CONNECTIONS BETWEEN BEAMS AND HSS HOLLOW COLUMNS
SHALL UTILIZE WT SECTIONS OFFSET SUCH THAT THE CENTERLINE OF THE BEAM AND CENTERLINE OF
THE COLUMN ALIGN.
6. FIELD CUTTING OF STRUCTURAL STEEL MEMBERS BY ANY TRADE SHALL NOT BE PERMITTED. BOLT
HOLES SHALL NOT BE CUT OR ENLARGED BY FLAME CUTTING IN THE FIELD.
7. ALL FIELD-BOLTED SHEAR CONNECTIONS SHALL BE SNUG TIGHT BEARING-TYPE CONNECTIONS, THREADS INCLUDED IN THE SHEAR PLANE.
8. THE CONTRACTOR SHALL SUBMIT FOR APPROVAL DRAWINGS AND DESIGN CALCULATIONS FOR ANY ALTERNATE DETAILS AND MEMBER SPLICES. DRAWINGS AND CALCULATIONS SHALL BE SEALED BY AN
ENGINEER LICENSED IN THE STATE OF THE PROJECT.
9. SHOP OR FIELD SPLICES OF STRUCTURAL STEEL MEMBERS ARE PROHIBITED EXCEPT AS DETAILED ON THE DRAWINGS, PERMITTED IN THE SPECIFICATIONS, AS INDICATED ON APPROVED SUBMITTALS, AND AS SPECIFICALLY APPROVED ON SHOP DRAWINGS PRIOR TO FABRICATION.
10. PAINT ALL STEEL BELOW GRADE WITH BITUMINOUS COATING.
11. ALL STEEL EXPOSED TO WEATHER SHALL BE HOT-DIPPED GALVANIZED IN ACCORDANCE WITH ASTM A123 FOR MEMBERS AND ASTM A153 FOR CONNECTION ELEMENTS, EXCEPT THAT ARCHITECTURALLY EXPOSED STRUCTURAL STEEL SHALL BE BLAST CLEANED AND COATED IN ACCORDANCE WITH THE
STRUCTURAL STEEL AND PAINT SPECIFICATIONS. COORDINATE ALL STEEL FINISHES WITH
ARCHITECTURAL DRAWINGS AND SPECIFICATIONS.
12. REFER TO SPECIFICATION 05 12 00 FOR ADDITIONAL INFORMATION.
13. STAIR SHALL BE DESIGNED AND DETAILED BY THE FABRICATOR. SUBMIT SEALED CALCULATIONS AND
SHOP DRAWINGS.
MASONRY CONSTRUCTION NOTES:
1. ALL MASONRY CONSTRUCTION SHALL BE IN ACCORDANCE WITH "BUILDING CODE REQUIREMENTS FOR
MASONRY STRUCTURES" (TMS 402-16) AND "SPECIFICATION FOR MASONRY STRUCTURES" (TMS
602-16).
2. DESIGN MASONRY ASSEMBLAGE STRENGTH, f'm = 2000 PSI. NET AREA COMPRESSIVE STRENGTH OF
CONCRETE MASONRY UNITS SHALL BE A MINIMUM OF 2800 PSI.
3. CONCRETE MASONRY UNITS SHALL CONFORM TO ASTM C90 AND BE MANUFACTURED WITH NORMAL
WEIGHT AGGREGATE.
4. GROUT SHALL CONFORM TO ASTM C476 AND SHALL NOT CONTAIN ADMIXTURES. GROUT SHALL ATTAIN A MINIMUM 28-DAY COMPRESSIVE STRENGTH OF 2500 PSI. ALL CMU ON THIS STRUCTURE SHALL BE
GROUT FILLED TO MEET BALLISTIC REQUIREMENTS.
5. REINFORCEMENT SHALL BE DEFORMED BARS CONFORMING TO ASTM A615/A615M, GRADE 60 AND
SHALL HAVE FABRICATION TOLERANCES IN ACCORDANCE WITH ACI 315. SHOP FABRICATE
REINFORCING BARS WHICH ARE INDICATED TO BE BENT OR HOOKED.
6. LOCATE JOINT REINFORCEMENT 16 INCHES ON CENTER VERTICALLY AND ADDITIONALLY AT THE TOP OF ALL FOUNDATIONS AND IN THE TWO JOINTS IMMEDIATELY ABOVE AND BELOW ALL OPENINGS, EXTENDING A MINIMUM OF 24 INCHES BEYOND THE JAMB ON EACH SIDE.
7. PLACE PIPES AND CONDUITS PASSING HORIZONTALLY THROUGH MASONRY IN STEEL OR PVC SLEEVES
OR CORED HOLES UNLESS OTHERWISE INDICATED ON THE DRAWINGS.
8. ALUMINUM CONDUITS, PIPES, AND ACCESSORIES SHALL NOT BE EMBEDDED IN MASONRY GROUT, OR
MORTAR, UNLESS EFFECTIVELY COATED OR COVERED TO PREVENT ALUMINUM-CEMENT CHEMICAL
REACTION OR ELECTROLYTIC REACTION BETWEEN ALUMINUM AND STEEL.
9. PLACE REINFORCEMENT IN BLOCK CELLS USING NONMETALLIC BAR POSITIONERS TO ACHIEVE COVER
REQUIREMENTS SHOWN IN MASONRY DETAILS AND SCHEDULES AND IN SPECIFICATIONS.
10. PROVIDE DOWEL REINFORCEMENT FROM WALLS INTO FOUNDATION OF SAME SIZE AND SPACING AS VERTICAL WALL REINFORCEMENT. LAP WALL REINFORCEMENT AS SPECIFIED IN SCHEDULE ON SHEET
SB502.
11. UNLESS OTHERWISE NOTED OR DETAILED, CENTER WALL REINFORCEMENT IN BLOCK CELLS. USE
NONMETALLIC BAR POSITIONERS.
12. REFER TO MASONRY SPECIFICATIONS FOR HOT AND COLD WEATHER CONSTRUCTION PROCEDURES.
13. ALL CMU WALL REINFORCEMENT SHALL HAVE STANDARD 90 DEGREE HOOKS AT TOP OF WALLS.
POST INSTALLED ANCHOR NOTES:
1. CONTRACTOR SHALL PROVIDE ANCHOR OF THE SIZE AND TYPE INDICATED IN THE DRAWINGS THAT MEET OR EXCEED THE INDICATED LOADS. THE CAPACITY OF THE ANCHOR SHALL BE MODIFIED BASED ON EMBEDMENT, EDGE DISTANCE AND SPACING OF THE ANCHOR. PRODUCT DATA AND CALULATIONS FOR THE PROPOSED ANCHOR SHALL BE SUBMITTED AT LEAST 30 DAYS PRIOR TO INSTALLATION OF THE POST INSTALLED ANCHOR. SUBMIT ANCHOR DESIGN CALCULATIONS SEALED BY A PROFESSIONAL
ENGINEER.
2. CONTRACTOR SHALL LOCATE REBAR IN CONCRETE OR CMU PRIOR TO DRILLING HOLES SO AS TO NOT
DAMAGE THE REINFORCING STEEL.
3. ALL MECHANICAL ANCHORS ANCHORED INTO CONCRETE SHALL HAVE BEEN TESTED IN ACCORDANCE
WITH ACI355.2 AND/OR ICC-ES AC193 FOR CRACKED OR UNCRACKED CONCRETE AND SESMIC
APPLICATIONS. MECHANICAL ANCHORS IN CONCRETE SHALL BE DESIGNED FOR AN ULTIMATE SHEAR
LOAD OF 2,000 LBS UNO OR AN ULTIMATE TENSION LOAD OF 1,000 LBS UNO.
4. ALL MECHANICAL ANCHORS ANCHORED INTO GROUT-FILLED CMU SHALL HAVE BEEN TESTED IN
ACCORDANCE WITH ICC-ES AC01 (EXPANSION ANCHORS) OR ICC ES AC106 (SCREW ANCHORS).
MECHANICAL ANCHORS IN GROUT-FILLED CMU SHALL BE DESIGNED FOR AN ALLOWABLE SHEAR LOAD
OF 1,000 LBS UNO OR AN ALLOWABLE TENSION LOAD OF 1000 LBS UNO.
5. SEE SECTIONS AND DETAILS WHERE ANCHORS SHALL SUPPORT COMBINED SHEAR AND TENSION
LOADS.
6. POST INSTALLED ANCHORS SHALL NOT BE INSTALLED IN HEAD JOINTS OF CMU.
7. POST INSTALLED ANCHORS SHALL NOT BE INSTALLED IN UNGROUTED CMU.
8. FOLLOW MANUFACTURER'S WRITTEN INSTRUCTIONS FOR INSTALLATION OF ALL POST INSTALLED
ANCHORS.
9. ALL ANCHORS INTO CONCRETE SHALL BE APPROVED FOR USE IN CRACKED CONCRETE AND SHALL BE
DESIGNED FOR CRACKED CONCRETE UNO.
10. A MANUFACTURER'S REPRESENTATIVE SHALL BE ONSITE TO PROVIDE ONSITE TRAINING FOR ALL OF THE ANCHORING PRODUCTS TO BE USED ON THE PROJECT. ALL PERSONNEL WHO INSTALL ANCHORS SHALL BE TRAINED A MINIMUM OF 1 WEEK PRIOR TO COMMENCEMENT OF ANCHOR INSTALLATION.
SHEET ID
D R
AW
N
B Y:
D
ES
IG
N
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
FI
LE
N
AM
E:
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
C H
EC
KE
D B
Y:
US Army Corps of Engineers ®
D
C
B
A
C
AT
EG
O
R Y
C O
D E:
AN
SI
D
E
F
G
2 3 4 5 6 7 8 9 10
C:\Users\k6enxmdz\Desktop\Tele-Work Revit Projects\Sey0144 (PN VKAG1073433)\1OW\FY20PNVKAG1073433_ECP_OW_STRUC_R18_TW Current.rvt2/26/2021 1:41:07 PM
M
AR
C H
W
2H N
-2 1-
B-
M . Z
AI
TZ
M . Z
AI
TZ
S.
B
AR
BI
N A
2-
0-
S-001
G
EN
ER
AL
S
TR
U C
TU
R
AL
N
O
TE
S
SA
VA
N N
AH
D
IS
TR
IC
T
W . O
G
LE
TH
O
R
PE
A
VE
SA
VA
N
N
AH
, G A
SE
YM
O U
R J
O H
N
SO
N A
IR
F
O R
C E
BA
SE
, N O
R
TH
C
AR
O
LI
N A
BE
R
KE
LE
Y G
AT
E
EN
TR
Y C
O N
TR
O
L
PO
IN
T
FY
, P N
V
KA
G
VO
LU
M
E
-O
VE
R W
AT
C
H F
AC
IL
IT
Y
J.
W
H
IT
TA
KE
R
READY TO ADVERTISE (RTA)
M
AR
K D
ES
C
R
IP
TI
O
N D
STRUCTURAL LEGEND
SLOPE DIRECTION
INDICATES ELEVATION
REFERENCED
TO FINISHED FLOOR
KEYED PLAN NOTE
COLUMN REFERENCE LINE
(CENTER LINE OF COLUMN)
SPOT ELEVATION
DN
X
[+/- X’-X”]
X
[+/- X’-X”]
SLAB DEPRESSION
BRICK WALL
CONCRETE ELEMENT
COMPACTED EARTH FILL
GROUT
CONCRETE MASONRY UNIT
(CMU)
POROUS FILL
WELDED WIRE FABRIC (WWF)
AISC SHAPE DESIGNATION
INDICATES # OF SHEAR STUDS WELDED
TO TOP FLANGE OF BEAM PER
GENERAL NOTES
HSSXxX
BPX
AISC COLUMN
DESIGNATION
BASE PLATE SIZE
STEEL COLUMN
BRACED FRAME LOCATION
BRACED/MOMENT
FRAME DESIGNATION
STEEL FRAMING REFERENCE
WXxXX [XX]
(B/M)F#X
[X]
BEAM END REACTION
[X]
MOMENT CONNECTION
DESIGNATION
LIGHT GAUGE STEEL NOTES:
1. ROOF LAYOUT AND COMPONENTS SHOWN ON THE DRAWINGS ARE FOR GENERAL CONFIGURATION ONLY. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL DIMENSIONS, ELEVATIONS, CONNECTION DETAILS, QUANTITIES, ETC. NECESSARY FOR THE COMPLETE DESIGN, FABRICATION, AND ERECTION
OF THE FRAMING SYSTEM. THE CONTRACTOR SHALL COORDINATE THE DESIGN WITH THE
ARCHITECTURAL PLANS, ELEVATIONS, AND DETAILS. DESIGN SHALL BE COORDINATED WITH THE
MECHANICAL CONTRACTOR AND WEB MEMBERS SHALL BE COORDINATED TO ACCOMODATE
EQUIPMENT, DUCTS, AND PIPES, AS REQUIRED. COORDINATE MEP LAYOUTS WITH EQUIPMENT
SUPPLIERS.
2. COLD-FORMED TRUSSES SHALL BE DESIGNED IN ACCORDANCE WITH THE AMERICAN IRON AND STEEL INSTITUTE (AISI) SPECIFICATION FOR THE DESIGN OF COLD-FORMED STEEL STRUCTURAL MEMBERS.
3. LIGHT GAUGE FRAMING MEMBERS SHALL BE DESIGNED IN ACCORDANCE WITH THE AMERICAN IRON AND STEEL INSTITUTE (AISI) SPECIFICATION FOR THE DESIGN OF COLD-FORMED STEEL STRUCTURAL
MEMBERS.
4. ALL CALCULATIONS AND DRAWINGS USED IN THIS DESIGN MUST BE SIGNED AND STAMPED BY A PROFESSIONAL ENGINEER AND SUBMITTED FOR APPROVAL. IN ADDITION TO THE CALCULATIONS, THE SUBMITTAL SHALL INCLUDE DETAILS OF THE CONNECTIONS, ERECTION PLAN, LAYOUT, OUTRIGGERS, BRIDGING, AND BOTH TEMPORARY AND PERMANENT BRACING INCLUDING DIAPHRAGM FORCES, HEADERS, SILLS, AND JAMBS..
5. THE CONTRACTOR SHALL SUBMIT COMPLETE PRODUCT CATALOGS FROM THE MATERIAL
MANUFACTURER FOR REVIEW PRIOR TO FABRICATION. THE CATALOGS SHALL INDICATE
QUALIFICATION, MATERIAL SPECIFICATIONS, DESIGN REFERENCES, ETC.
6. ALL COLD-FORMED STEEL MEMBERS, THEIR COMPONENTS, AND CONNECTION MATERIAL SHALL BE
GALVANIZED. PREPARE AND REPAIR DAMAGED GALVANIZED COATINGS ON FABRICATED AND
INSTALLED LIGHT GAUGE METAL FRAMING WITH GALVANIZING REPAIR PAINT ACCORDING TO ASTM
A780 AND/OR THE MANUFACTURER'S RECOMMENDATIONS.
7. COLD-FORMED STEEL MEMBERS SHALL BE Fy=33KSI FOR MEMBERS 43 MILS (18 GA) AND Fy=50KSI FOR
MEMBERS 54 MILS (16 GA) AND HEAVIER. USE MIN 6" WIDE STUDS AT TRUSSES UNO.
8. ALL WELDING OF LIGHT GAUGE STEEL SHALL COMPLY WITH AWS D1.1 AND AWS D1.3 FOR WELDING
BASE MATERIAL LESS THAN 1/8" THICK.
9. TRUSS DEFLECTION LIMITS SHALL BE IN ACCORDANCE WITH IBC 2018.
10. BRIDGING AND BRACING OF TRUSS COMPRESSION MEMBERS SHALL BE INSTALLED IN ACCORDANCE WITH THE TRUSS MANUFACTURERS DESIGN AND DIRECTIONS. TRUSSES SHALL BE BRACED SECURELY BOTH DURING ERECTION AND AFTER PERMANENT INSTALLATION BY THE CONTRACTOR. ERECTION
BRACING SHALL HOLD TRUSSES STRAIGHT AND PLUMB UNTIL DECKING AND PERMANENT TRUSS
BRACING HAVE BEEN INSTALLED. ALL BRACING SHALL BE INSTALLED PRIOR TO THE LOADING OF THE
TRUSSES. THE BOTTOM CHORD SHALL NOT BE ASSUMED TO BE LATERALLY SUPPORTED BY THE
CEILING CONSTRUCTION.
11. TRUSS TOP CHORD SHALL HAVE A MINIMUM THICKNESS OF 54 MIL (16 GA).
STEEL DECK NOTES:
1. ROOF DECK SHALL BE GALVANIZED STEEL CONFORMING TO ASTM A653 WITH A MINIMUM YIELD STRENGTH OF 50 KSI. STEEL ROOF DECK SHALL BE AS SHOWN ON DRAWINGS. ROOF DECK OVER LT GAUGE TRUSSES SHALL BE FASTENED TO TRUSSES WITH #12 TEK SCREWS WITH A 36/7 PATTERN AND
(4) #10 SELF TAPPING SCREWS PER SPAN AT SIDE LAP CONNECTIONS. ATTACH TO ROOF BENT PLATES
AT HIPS, RIDGE AND EDGES AT 6" O.C.
2. NON-COMPOSITE FLOOR DECK FOR SHALL BE GALVANIZED STEEL CONFORMING TO ASTM 653 WITH A MINIMUM YIELD STRENGTH OF 50 KSI. NON-COMPOSITE STEEL FLOOR DECK SHALL BE AS SHOWN ON
DRAWINGS. NON-COMPOSITE FLOOR DECK SHALL BE FASTENED TO THE SUPPORTING STRUCTURE
WITH 5/8" PUDDLE WELDS AT A 36/5 PATTERN AND SIDELAPS WITH (2) #10 TEK SCREWS PER SPAN.
FASTEN DISCONTINUOUS SIDE OF FORM DECK TO SUPPORTING STRUCTURE WITH 5/8" PUDDLE WELDS
UNLESS OTHERWISE NOTED.
3. PROVIDE ALL RIDGE PLATES, VALLEY PLATES, CLOSURE PLATES, POUR STOPS, AND ALL OTHER
ACCESSORIES REQUIRED FOR COMPLETE INSTALLATION IN ACCORDANCE WITH THE DECK
MANUFACTURER'S RECOMMENDATIONS.
4. CONTRACTOR SHALL COORDINATE OPENINGS IN STEEL DECK WITH ARCHITECTURAL, MECHANICAL, AND ELECTRICAL DRAWINGS PRIOR TO DECK PLACEMENT.
5. HANGING LOADS DIRECTLY FROM ROOF DECK IS PROHIBITED.
6. STEEL DECK SHALL SPAN CONTINUOUSLY OVER A MINIMUM OF 4 SUPPORTS (3 SPANS) UNO.
STRUCTURAL ABBREVIATIONS
SYMBOL DESCRIPTION
AFF ABOVE FINISHED FLOOR
AHU AIR HANDLING UNIT
APPROX APPROXIMATELY
ARCH ARCHITECTURAL
BOC BOTTOM OF CONCRETE
BOF BOTTOM OF FOOTING
BOM BOTTOM OF MASONRY
BOS BOTTOM OF STEEL
BOT BOTTOM
BRG BEARING
BTWN BETWEEN
CJ CONSTRUCTION JOINT
CL CENTER LINE
CLR CLEAR
CMU CONCRETE MASONRY UNIT
COL COLUMN
CONN CONNECTION
CONC CONCRETE
CONT CONTINUOUS
CONSTR CONSTRUCTION
DCJ DOWELED CONSTRUCTION JOINT
DEG DEGREE
DIA DIAMETER
DN DOWN
DWG(S) DRAWING(S)
EA EACH
EF EACH FACE
EJ EXPANSION JOINT
EL ELEVATION
EOF EDGE OF FOUNDATION
EOS EDGE OF SLAB
EQ EQUAL
ERV ENERGY RECOVERY VENTILATOR
EW EACH WAY
FF FINISHED FLOOR
FDN FOUNDATION
FTG FOOTING
GA GAUGE
GALV GALVANIZED
GFGI GOVT
HORIZ HORIZONTAL
IJ ISOLATION JOINT
SYMBOL DESCRIPTION
KIP (k) 1000 POUNDS
LG LONG
LLH LONG LEG HORIZONTAL
LLV LONG LEG VERTICAL
MAX MAXIMUM
MBM METAL BUILDING MANUFACTURER
MECH MECHANICAL
MEP MECHANICAL, ELECTRICAL, PLUMBING
MFR MANUFACTURER
MIN MINIMUM
NTS NOT TO SCALE
OC ON CENTER
OPP OPPOSITE
PJF PREMOLDED JOINT FILLER
PL PLATE
PLF POUNDS PER LINEAR FOOT
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
REINF REINFORCEMENT
REQD REQUIRED
SCHED SCHEDULE
SE SLAB EDGE
SJ SAWED CONTRACTION JOINT
SJI STEEL JOIST INSTITUTE
SIM SIMILAR
SL SLOPE(D)
SOG SLAB ON GRADE
SPCG SPACING
STD STANDARD
T&B TOP AND BOTTOM
TO TOP OF
TOC TOP OF CONCRETE
TOF TOP OF FOOTING
TOM TOP OF MASONRY
TOS TOP OF SLAB
TS THICKENED SLAB
TYP TYPICAL
UNO UNLESS NOTED OTHERWISE
VEF VEHICLE EXHAUST FAN
VERT VERTICAL
WP WORKING POINT
WWF WELDED WIRE FABRIC
SPECIAL INSPECTION NOTES:
1. INSPECTION OF FABRICATORS SHALL BE CONDUCTED IN ACCORDANCE WITH IBC 2018,
SECTION 1704.2.5.
2. INSPECTION OF STEEL CONSTRUCTION SHALL BE CONDUCTED IN ACCORDANCE WITH IBC 2018, SECTION 1705.2.
3. INSPECTION OF CONCRETE CONSTRUCTION SHALL BE CONDUCTED IN ACCORDANCE WITH IBC 2018, SECTION 1705.3 AND TABLE 1705.3.
4. INSPECTION OF MASONRY CONSTRUCTION SHALL BE CONDUCTED IN ACCORDANCE WITH IBC 2018, SECTION 1705.4.
5. INSPECTIONS FOR WIND AND SEISMIC RESISTANCE SHALL BE AS PER IBC 2018, SECTION 1705.11
AND 1705.12.
6. INCLUDE SPECIAL INSPECTIONS REQUIREMENTS IN CONTRACTOR'S QUALITY CONTROL (CQC)PLAN.
7. THE CONTRACTOR SHALL RETAIN THIRD PARTY QUALITY CONTROL AGENCIES TO CONDUCT SPECIAL
INSPECTIONS REQUIRED BY IBC. INSPECTING AGENCY SHALL PROVIDE REPORTS OF SPECIAL
INSPECTIONS DIRECTLY TO THE GOVERNMENT.
ZONE 1
ROOF
OVERWATCH FACILITY
COMPONENTS AND CLADDING GROSS WIND PRESSURES (PSF)
ULTIMATE
('a' = 3'-0")
WALL
1. GROSS WIND PRESSURES SHOWN ABOVE CORRESPOND TO WIND
PRESSURE DIAGRAMS.
2. WIND PRESSURES SHOWN SHALL BE USED IN CONJUNCTION WITH LOAD
COMBINATIONS SPECIFIED IN SECTIONS 2.3 AND 2.4 OF ASCE 7-16.
3. NEGATIVE WIND PRESSURES REPRESENT WIND PRESSURES ACTING
AWAY FROM THE COMPONENT AND CLADDING SURFACES.
4. VALUES IN TABLES ARE GROSS VALUES.
ZONE 2e
+38 / -41
ZONE 4 ZONE 5ZONE 3
10 SF
EFFECTIVE
WIND
AREA
20 SF
50 SF
100 SF
+36 / -39
+34 / -37
+32 / -35
ROOF WALL
45 5
TYP
a
2e
2r
2r 2r1 12e 2e
2e
+28 / -47
+20 / -42
+16 / -38
ZONE 2r
+38 / -51
+36 / -47
+34 / -43
+32 / -39
+28 / -63
+25/ -58
+20 / -51
+16 / -46
+28 / -82
+25 / -74
+20 / -63
+16 / -55
+28 / -63
+25 / -58
+20 / -51
+16 / -46
ROOF OVERHANG
ZONE 3ZONE 1 ZONE 2
-73
-66
-56
-48
-99
-94
-87
-82
TYP
a
2r
+25 / -47
-99
-94
-87
-82
SHEET ID
D R
AW
N
B Y:
D
ES
IG
N
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
FI
LE
N
AM
E:
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
C H
EC
KE
D B
Y:
US Army Corps of Engineers ®
D
C
B
A
C
AT
EG
O
R Y
C O
D E:
AN
SI
D
E
F
G
2 3 4 5 6 7 8 9 10
C:\Users\k6enxmdz\Desktop\Tele-Work Revit Projects\Sey0144 (PN VKAG1073433)\1OW\FY20PNVKAG1073433_ECP_OW_STRUC_R18_TW Current.rvt2/26/2021 1:41:10 PM
M
AR
C H
W
2H N
-2 1-
B-
M . Z
AI
TZ
M . Z
AI
TZ
S.
B
AR
BI
N A
2-
0-
S-002
G
EN
ER
AL
S
TR
U C
TU
R
AL
N
O
TE
S
SA
VA
N N
AH
D
IS
TR
IC
T
W . O
G
LE
TH
O
R
PE
A
VE
SA
VA
N
N
AH
, G A
SE
YM
O U
R J
O H
N
SO
N A
IR
F
O R
C E
BA
SE
, N O
R
TH
C
AR
O
LI
N A
BE
R
KE
LE
Y G
AT
E
EN
TR
Y C
O N
TR
O
L
PO
IN
T
FY
, P N
V
KA
G
VO
LU
M
E
-O
VE
R W
AT
C
H F
AC
IL
IT
Y
J.
W
H
IT
TA
KE
R
READY TO ADVERTISE (RTA)
COMPONENT AND CLADDING WIND PRESSURES1
M
AR
K D
ES
C
R
IP
TI
O
N D
10' - 0"
SB501
S
S
TOF EL = 102.00
NO SLAB ON GRADE
UNDER OVERWATCH.
PLACE VAPOR RETARDER
ON TOP OF GRADE.
TD TYP
5' - 6" 8'
6"
SB501
STAIR COLUMN FOOTING, SEE SB501.
LOCATION BY STAIR VENDOR
TOS EL = 104.5
TOF = 104.5
1. FOR GENERAL STRUCTURAL NOTES AND ABBREVIATIONS,
SEE S-001 AND FOLLOWING.
2. SEE SB501 AND FOLLOWING FOR SLAB AND FOUNDATION
SECTIONS AND DETAILS.
3. SEE CIVIL DRAWINGS FOR DATUM.
4. TOP OF FTG EL = 103.33 UNO
5. S DENOTES FOOTING STEP. SEE DETAIL ON SB502.
6. ALL FOOTINGS AND WALL FOOTINGS SHALL BE CENTERED
UNDER COLUMNS AND WALLS, U.N.O.
7. COORDINATE UNDERGROUND UTILITY LINES WITH CIVIL,
ELECTRICAL PLUMBING, AND FIRE PROTECTION
DRAWINGS PRIOR TO CONSTRUCTION OF FOOTINGS AND
SLABS-ON-GRADE.
8. DRAINAGE AND DEWATERING: ALL EXCAVATION SHALL BE
PERFORMED SO THAT THE SITE AND THE AREA
IMMEDIATELY SURROUNDING THE SITE WHICH AFFECTS
CONSTRUCTION OPERATIONS WILL BE CONTINUALLY AND
EFFECTIVELY DRAINED. THE CONTRACTOR SHALL
PROVIDE DRAINAGE AND DEWATERING AS REQUIRED TO
ENSURE THAT ALL FOOTING EXCAVATIONS ARE
ACCOMPLISHED WITH THE SUBGRADE SOILS REMAINING
DRY AND FIRM UNTIL AFTER FOOTINGS ARE PLACED AND
BACKFILLED. REMOVAL OF SURFACE WATER,
GROUNDWATER, AND ANY PERCHED-WATER CONDITIONS,
WHICH MIGHT BE ENCOUNTERED DURING EXCAVATIONS
SHALL BE ACCOMPLISHED BY APPROVED MEANS. REFER
TO SPECIFICATION 31 00 00 EARTHWORK FOR ADDITIONAL
REQUIREMENTS.
1. SEE S-001 AND S-002 FOR GENERAL STRUCTURAL NOTES,
ABBREVIATIONS, AND DESIGN CRITERIA.
2. SEE SB501 AND FOLLOWING FOR SLAB ON GRADE
DETAILS AND SECTIONS.
3. TOP OF CONCRETE SLAB-ON-GRADE ELEVATION = 0'-0".
ALL ELEVATIONS INDICATED FROM THIS DATUM. SEE CIVIL
DRAWINGS FOR EXACT ELEVATION.
4. COORDINATE UNDERGROUND UTILITY LINES WITH CIVIL,
ELECTRICAL, PLUMBING, AND FIRE PROTECTION
DRAWINGS PRIOR TO CONSTRUCTION OF FOOTINGS AND
SLABS-ON-GRADE.
5. SLAB-ON-GRADE (STOOP) SHALL CONSIST OF 5" THICK
CONCRETE REINFORCED WITH 6X6 W2.9XW2.9 WWF
LOCATED AT 1/3-DEPTH FROM TOP OF SLAB.
6. TD DENOTES TURN DOWN. SEE DETAIL ON SHEET SB501.
SHEET ID
D R
AW
N
B Y:
D
ES
IG
N
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
FI
LE
N
AM
E:
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
C H
EC
KE
D B
Y:
US Army Corps of Engineers ®
D
C
B
A
C
AT
EG
O
R Y
C O
D E:
AN
SI
D
E
F
G
2 3 4 5 6 7 8 9 10
C:\Users\k6enxmdz\Desktop\Tele-Work Revit Projects\Sey0144 (PN VKAG1073433)\1OW\FY20PNVKAG1073433_ECP_OW_STRUC_R18_TW Current.rvt2/26/2021 1:41:12 PM
M
AR
C H
W
2H N
-2 1-
B-
M . Z
AI
TZ
M . Z
AI
TZ
S.
B
AR
BI
N A
2-
0-
SB101
FO
U
N D
AT
IO
N A
N D
S
LA
B
PL
AN
SA
VA
N N
AH
D
IS
TR
IC
T
W . O
G
LE
TH
O
R
PE
A
VE
SA
VA
N
N
AH
, G A
SE
YM
O U
R J
O H
N
SO
N A
IR
F
O R
C E
BA
SE
, N O
R
TH
C
AR
O
LI
N A
BE
R
KE
LE
Y G
AT
E
EN
TR
Y C
O N
TR
O
L
PO
IN
T
FY
, P N
V
KA
G
VO
LU
M
E
-O
VE
R W
AT
C
H F
AC
IL
IT
Y
J.
W
H
IT
TA
KE
R
READY TO ADVERTISE (RTA)
PLAN NORTH
04 8268 02 4 8134
SCALE: 1/4"=1'-0"
SCALE AND NORTH ARROW
OVERWATCH FOUNDATION PLAN1
OVERWATCH SLAB PLAN2
FOUNDATION PLAN NOTES
SLAB PLAN NOTES
M
AR
K D
ES
C
R
IP
TI
O
N D
8" FULLY GROUTED
CMU
BRICK VENEER,
SEE ARCH
FILL WITH GROUT
TO GRADE
EXT. GRADE,
SEE CIVIL
(6) #5 T&B
CONT,
HOOKED AT
CORNERS.
SEE 3/SB502
#5 TRANSVERSE @ 12"
OC T&B
#5 DOWEL @ 16" OC, STD
HOOK AT BOT
TOF
INSULATION, SEE
ARCH
4' - 6"
#5 @ 16" OC, CENTERED IN
CELL. GROUT ALL CELLS OF
WALL.
GRADE UNDER BUILDING
SHALL BE HIGHER THAN
EXTERIOR GRADE
2' - 3"
OUTSIDE FACE OF CMU
1'
0" 1
(4) #5 CONT, PROVIDE
CORNER BARS AT
CORNERS
WWF, SEE PLAN
FF
1'
8"
1' - 0"
GRADE,
SEE CIVIL
DOUBLE REINF IN 8" CMU
SINGLE REINF IN 8" CMU
EQ
NOTES:
ALL CELLS WITH REBAR SHALL BE FILLED WITH GROUT.
BARS SHALL BE LOCATED WITH REBAR POSITIONERS AND
SHALL BE ACCURATELY LOCATED PRIOR TO INSTALLATION
OF GROUT.
LAP REBAR PER ACI 530.
1/
2"
EQ
16" MAX 16" MIN 16" MAX
(2)#5 HORIZONTAL
GROUTED SOLID
EXTEND 24"
BEYOND EDGE OF
OPENING
GROUT
OPENING
AFTER
INSTALLING
CONDUIT
A
A A-A
SEE CIVIL
WALL CORNER
OPENING - WALL TERMINATION
VERTICAL WALL
REINFORCING
WALL INTERSECTION#5 IN 2 CELLS EA
SIDE OF OPENING
NOTES:
1. INTERMEDIATE HORIZONTAL BOND BEAM REINFORCING SHALL TERMINATE AT CMU CONTROL JOINTS.
REINFORCING FOR BOND BEAMS AT TOP OF WALLS SHALL BE CONTINUOUS.
2. HORIZONTAL BARS SHALL BE ANCHORED AROUND VERTICAL BARS WITH A STANDARD HOOK.
VERTICAL WALL
REINFORCING
EQ EQ
EQEQ
5/
8"
EQ EQ
SEE PLAN
WALL
OPENING
EQ EQ
HORIZONTAL BOND BEAM
REINFORCING WITH 90
DEGREE SPLICE BAR
HORIZONTAL BOND BEAM
REINFORCING WITH 90
DEGREE SPLICE BAR
HORIZONTAL BOND BEAM
REINFORCING WITH 180
DEGREE HOOKS AT WALL
ENDS
BOND BEAM AT TOP OF WALL AND AT
FLOOR LEVEL - SEE PLAN AND
DETAILS FOR LOCATIONS AND
REINFORCING
PLACE METAL LATH OR WIRE SCREEN
OVER CORES NOT TO BE FILLED
(SHEET METAL AND FELT
PROHIBITED)
VERTICAL REINFORCING WITH MATCHING
DOWELS INTO FOUNDATION. SEE PLAN
FOR SIZE AND LOCATION. PROVIDE BAR
POSITIONERS PER PROJECT
SPECIFICATIONS SECTION 04 20 00.
HORIZONTAL JOINT REINFORCING @ 16"
O.C. STARTING AT FIRST COURSE ABOVE
FOUNDATION. LAP SPLICES 8". USE
PREFABRICATED L'S AND T'S AT WALL
INTERSECTIONS.
GROUT FILLED CELL AT REINFORCING
LOCATIONS - PLACE AND CONSOLIDATE
GROUT IN 5 FOOT LIFTS (MAX)
MORTAR CROSS WEBS ADJACENT TO
FILLED CELLS
ASTM C90 CMU UNITS IN RUNNING BOND
FOUNDATION OR THICKENED SLAB
SET FIRST COURSE IN
FULL MORTAR BEDDING
PROVIDE CLEAN OUT
OPENINGS AT GROUT
FILLED CELL LOCATIONS
2'-6"x2'-6"x1'-4" DEEP
FOOTING WITH (3)#5
EW
3/4"x10"x10" BASE
PLATE WITH
(4)-5/8" DIA
ANCHOR BOLTS
WITH 10" EMBED
T/FTG
MATCHES PAD ELEV
COLUMN, BY STAIR VENDOR
2" NON SHRINK GROUT
GRADE, SEE CIVIL AND ARCH.
MULTI-WYTHE
BRICK WALL,
SEE DETAILS THIS
SHEET
EXT. GRADE,
SEE CIVIL
(4) #4 T&B
#4 TRANSVERSE @ 12"
OC T&B3' - 6"
#3 DOWEL W/ 12" HOOK @ 8" OC,
CENTERED IN WALL AND GROUTED
WITH 3000 PSI GROUT. EXTEND
FULL HT OF WALL
1'
0"
SEE PLAN FOR DIMENSIONS AND
PILASTERS. EXTEND FOOTING 2
FEET PAST PILASTERS.
REINFORCE PILASTERS SIMILAR
TO PILASTERS SHOWN ON CIVIL
SHEETS.
TOP OF FOOTING 8" BELOW GRADE
PROVIDE W1.7 LADDER
TYPE TIES AT 8" OC
MAX VERTICAL
SHEET ID
D R
AW
N
B Y:
D
ES
IG
N
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
FI
LE
N
AM
E:
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
C H
EC
KE
D B
Y:
US Army Corps of Engineers ®
D
C
B
A
C
AT
EG
O
R Y
C O
D E:
AN
SI
D
E
F
G
2 3 4 5 6 7 8 9 10
C:\Users\k6enxmdz\Desktop\Tele-Work Revit Projects\Sey0144 (PN VKAG1073433)\1OW\FY20PNVKAG1073433_ECP_OW_STRUC_R18_TW Current.rvt2/26/2021 1:41:15 PM
M
AR
C H
W
2H N
-2 1-
B-
M . Z
AI
TZ
M . Z
AI
TZ
S.
B
AR
BI
N A
2-
0-
SB501
FO
U
N D
AT
IO
N , S
LA
B
AN
D
C M
U D
ET
AI
LS
SA
VA
N N
AH
D
IS
TR
IC
T
W . O
G
LE
TH
O
R
PE
A
VE
SA
VA
N
N
AH
, G A
SE
YM
O U
R J
O H
N
SO
N A
IR
F
O R
C E
BA
SE
, N O
R
TH
C
AR
O
LI
N A
BE
R
KE
LE
Y G
AT
E
EN
TR
Y C
O N
TR
O
L
PO
IN
T
FY
, P N
V
KA
G
VO
LU
M
E
-O
VE
R W
AT
C
H F
AC
IL
IT
Y
J.
W
H
IT
TA
KE
R
READY TO ADVERTISE (RTA)
0SCALE: 3/4"=1'-0" 12 2
TYPICAL WALL FOOTING DETAIL1 TYPICAL TURN DOWN DETAIL (TD)2
0SCALE: 3/4"=1'-0" 12 2
CMU WALL REINFORCING DETAIL3
CONDUIT OPENING THROUGH CMU FDN WALLS4 TYPICAL CMU WALL REINFORCING DETAIL5 TYPICAL CMU CONSTRUCTION DETAIL6
0SCALE: 3/4"=1'-0" 12 2
TYPICAL STAIR COLUMN FOOTING7
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
NOT TO SCALE
NOT TO SCALENOT TO SCALENOT TO SCALE
TYPICAL ELECTRONIC SIGN DETAIL8
0SCALE: 3/4"=1'-0" 12 2
NOTES:
1. LENGTHS SHOWN IN THIS SCHEDULE SHALL BE USED UNLESS SPECIFICALLY NOTED
OTHERWISE ON DRAWINGS.
2. LAPPED BARS SHALL BE WIRE TIED TO THE GREATEST EXTENT POSSIBLE.
3. REINFORCING MAY BE CONSIDERED TO BE SPLICED WHEN PLACED IN ADJACENT
GROUTED CELLS AND IF THE BARS ARE SPACED NO FARTHER APART THAN 1/5 THE
REQUIRED LENGTH INDICATED OR 8" MAX.
4. VERTICAL REINFORCEMENT SHALL BE HELD IN PLACE USING BAR POSITIONERS AS
REQUIRED IN GENERAL NOTES AND SPECIFICATIONS.
BAR SIZE
SPLICE LENGTH
#3
8-in CMU
REINFORCEMENT IN
CENTER OF WALL
CMU REINFORCING SPLICE LENGTH SCHEDULE
#4 #5 #6 #7 #8 #9
NP
TRANSVERSE BARS
CONTINUOUS WALL
FOOTING REINFORCING
CONTINUOUS WALL
FOOTING REINFORCING
'Z' BARS SAME SIZE AND
NUMBER AS CONTINUOUS
REINFORCING, BEND AS
SHOWN
(TYPICAL)
24" LAP SPLICE
8" STEP
16" MIN
16" STEP
32" MIN
MIN
1' - 0"
" M
AX
8"
M
IN
" M
AX
8"
M
IN
3" CLR
NOTES:
1. WHERE THREE BARS OCCUR, CENTER BAR SHALL BE HAVE 90 DEGREE STANDARD HOOK.
TYPICAL FOOTING
REINFORCING, (TYP)
PLAN AT
CORNER
PLAN AT
INTERSECTION
BARS, (TYP)
0" BETWEEN
3' - 0"
3'
0"
'L' BAR TO MATCH
HORIZONTAL
REINFORCING
BA
R
S, (T
YP
0" B
ET
W
EE
N
TYPICAL FOOTING
REINFORCING, (TYP)
1'
6"
HOOKED SPLICE BAR
TO MATCH
HORIZONTAL FOOTING
OR WALL
REINFORCING
BARS, (TYP)
0" BETWEEN
1' - 6" 1' - 6"1' - 6"
SHEET ID
D R
AW
N
B Y:
D
ES
IG
N
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
FI
LE
N
AM
E:
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
C H
EC
KE
D B
Y:
US Army Corps of Engineers ®
D
C
B
A
C
AT
EG
O
R Y
C O
D E:
AN
SI
D
E
F
G
2 3 4 5 6 7 8 9 10
C:\Users\k6enxmdz\Desktop\Tele-Work Revit Projects\Sey0144 (PN VKAG1073433)\1OW\FY20PNVKAG1073433_ECP_OW_STRUC_R18_TW Current.rvt2/26/2021 1:41:21 PM
M
AR
C H
W
2H N
-2 1-
B-
M . Z
AI
TZ
M . Z
AI
TZ
S.
B
AR
BI
N A
2-
0-
SB502
FO
U
N D
AT
IO
N A
N D
C M
U D
ET
AI
LS
SA
VA
N N
AH
D
IS
TR
IC
T
W . O
G
LE
TH
O
R
PE
A
VE
SA
VA
N
N
AH
, G A
SE
YM
O U
R J
O H
N
SO
N A
IR
F
O R
C E
BA
SE
, N O
R
TH
C
AR
O
LI
N A
BE
R
KE
LE
Y G
AT
E
EN
TR
Y C
O N
TR
O
L
PO
IN
T
FY
, P N
V
KA
G
VO
LU
M
E
-O
VE
R W
AT
C
H F
AC
IL
IT
Y
J.
W
H
IT
TA
KE
R
READY TO ADVERTISE (RTA)
REBAR SPLICE LENGTH (CMU) SCHEDULE1 TYPICAL STEPPED FOOTING DETAIL2 TYPICAL CONT FTG REINF DETAIL3
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
NOT TO SCALE NOT TO SCALE NOT TO SCALE
1. FOR GENERAL STRUCTURAL NOTES AND ABBREVIATIONS,
SEE S-001 AND S-002.
2. SEE SF501 AND FOLLOWING FOR ROOF SECTIONS AND
DETAILS
3. COORDINATE ALL ROOF DIMENSIONS, ELEVATIONS,
OPENINGS AND PENETRATIONS WITH ARCHITECTURAL,
MECHANICAL, PLUMBING AND ELECTRICAL DRAWINGS. SEE
ARCHITECTURAL FOR ROOF PENETRATION WATERPROOFING
DETAILS.
4. TRUSS BEARING EL SHALL BE 118.70 UNO.
5. ROOF DECK SHALL BE 1.5B22 GAUGE METAL DECK. SEE
STEEL DECK NOTES FOR ATTACHMENT.
6. COLD FORM STEEL TRUSS TRUSS SPACING SHALL NOT
EXCEED 4'-0" O.C. UNO.
7. PROVIDE CONTINUOUS 1/4" BENT PLATE WITH 4" LEGS AT ALL
RIDGES.
8. TRUSS MANUFACTURER PROVIDE LT GA STRUCTURAL
MEMBER ALONG ALL HIP RIDGES TO SECURE THE 1/4" BENT
PLATE.
SF501
SF501
W8X10
STEEL STAIR BY
FABRICATOR, SEE
SPEC.
SF501
SF501
TRUSS DESIGNER DESIGN DRAG TRUSS FOR 150
PLF ULT DUE TO WIND LOAD TYP ALL 4 SIDES
GIRDER TRUSS
SF501
MECH UNIT HANGING FROM TRUSS. DESIGN
TRUSS FOR 200 LBS LOAD. CONTRACTOR
PROVIDE SUPPORT FOR UNIT (UNISTRUT, ETC).
CMU WALL BELOW
1. FOR GENERAL STRUCTURAL NOTES AND ABBREVIATIONS,
SEE S-001 AND S-002.
2. SEE SF501 AND FOLLOWING FOR FLOOR SECTIONS AND
DETAILS
3. COORDINATE ALL ROOF DIMENSIONS, ELEVATIONS,
OPENINGS AND PENETRATIONS WITH ARCHITECTURAL,
MECHANICAL, PLUMBING AND ELECTRICAL DRAWINGS. SEE
ARCHITECTURAL FOR ROOF PENETRATION WATERPROOFING
DETAILS.
4. TOP OF STEEL EL = 109.00 UNO. TOS EL = 109.33.
5. FLOOR DECK SHALL BE 1.5C22 GAUGE METAL DECK. SEE
STEEL DECK NOTES FOR FASTENERS. CONCRETE TOPPING
ON FORM DECK SHALL BE 4000 PSI 2 1/2" THICK (4" TOTAL
SLAB THICKNESS) AND REINFORCED WITH 6x6-W2.9/W2.9
WWF AT MID DEPTH.
SHEET ID
D R
AW
N
B Y:
D
ES
IG
N
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
FI
LE
N
AM
E:
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
C H
EC
KE
D B
Y:
US Army Corps of Engineers ®
D
C
B
A
C
AT
EG
O
R Y
C O
D E:
AN
SI
D
E
F
G
2 3 4 5 6 7 8 9 10
C:\Users\k6enxmdz\Desktop\Tele-Work Revit Projects\Sey0144 (PN VKAG1073433)\1OW\FY20PNVKAG1073433_ECP_OW_STRUC_R18_TW Current.rvt2/26/2021 1:41:24 PM
M
AR
C H
W
2H N
-2 1-
B-
M . Z
AI
TZ
M . Z
AI
TZ
S.
B
AR
BI
N A
2-
0-
SF101
FL
O
O R
A N
D R
O O
F
FR
AM
IN
G P
LA
N
SA
VA
N N
AH
D
IS
TR
IC
T
W . O
G
LE
TH
O
R
PE
A
VE
SA
VA
N
N
AH
, G A
SE
YM
O U
R J
O H
N
SO
N A
IR
F
O R
C E
BA
SE
, N O
R
TH
C
AR
O
LI
N A
BE
R
KE
LE
Y G
AT
E
EN
TR
Y C
O N
TR
O
L
PO
IN
T
FY
, P N
V
KA
G
VO
LU
M
E
-O
VE
R W
AT
C
H F
AC
IL
IT
Y
J.
W
H
IT
TA
KE
R
READY TO…
This is the start of the file's text. The full file is on GovTribe.