UNIT PRICE SCHEDULE NOTES AND DRAWINGS.doc
DOC document 182 KB Posted
- Solicitation number
- GS-07P-12-HHD-0009A
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Amendment II_West.pdf | ||
| C301.doc | DOC document | |
| Amendment I_West.pdf | ||
| Sol_Asbestos_Abatement_and_Mold_Remediation_Services_West 1 .doc | DOC document | |
| Question Answer.doc | DOC document | |
| Agreement for Asbestos Abatement and Mold Remediation Services Region 7 West.doc | DOC document | |
| Percentage factor agreement_West.doc | DOC document | |
| SF 1442_West.pdf | ||
| Document Security Notice.doc | DOC document | |
| Abatement IDIQ line Items Updated Feb 22 2012.xls | XLS spreadsheet | |
| SF 24(2).pdf | ||
| GSA 527.pdf | ||
| Specifications.doc | DOC document | |
| Sol_Asbestos_Abatement_and_Mold_Remediation_Services_West 1 .doc | DOC document |
Show all 14
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
UNIT PRICE SCHEDULE NOTES AND DRAWINGS:
The following notes and drawing explain and define the line items of the Price Schedule. The notes are numbered to refer to the appropriate line item. These notes are drawings from a part of the Price Schedule and Contract Specifications.
GENERAL NOTES
· See “Area Conversion Chart” which is attached for Work Item 46. It may be used to convert outer diameter of pipe insulation to surface area of insulation in square feet per linear foot.
The Conversion Chart may also be used to determine the surface area of “bared” piping to determine WI 43 costs.
· The unit costs for all work items which either remove ACM or which remove ACM contaminated non-ACM have already included the costs of packaging, transporting and proper disposal of the resulting Asbestos Waste at “approved landfills”.
· The unit costs for all work items which provide materials (e.g. scaffolding, plywood, wafer boards, planks, etc.) have already included the costs of transporting them to the project site, and to the work area, and back out of the work area, etc., and cutting costs, if required.
· For fittings (elbow, tees, valves, etc.) add 3 L.F.
1. Area = (D x 3 ft. where D = outer diameter in feet
2. Asbestos Contractor shall use this formula to calculate area to be used for each fitting.
· For each flange add 4 LF . Area = (D x 4 LF where D = outer diameter in feet
a. Asbestos Contractor shall use this formula to calculate area to be used for each flange.
UNIT NOTES
Units listed in the Unit Price Schedule are defined below:
| Unit |
| Symbol |
| Definition |
| Delivery Order |
| DO |
| Individual Delivery Order |
| Each |
| Ea. |
| Individual Work Item |
| Linear Feet |
| L.F. |
| Length of item of work, measured to the nearest half foot actually removed, installed or applied. Waste costs are included in the line item unit price. |
| Cubic Feet |
| C.F. |
| Volume of item of work, measured to the nearest half cubic foot actually removed. Waste costs are included in the line item unit price. |
| Square Feet |
| S.F. |
| Areas of items of work, calculated to the nearest half square foot. Calculations based on measurement of work actually removed, installed or applied. Waste costs are included in the line item unit price. |
| Pound |
| Lb. |
| Weight in pounds of metal bumper guard material |
| Scope of Work |
| SOW |
| Scope of Work of abatement project |
Note: See unit price schedule notes and drawings on the sheets which follow.
AREA CONVERSION CHART
This chart is provided for use in conjunction with the Price Schedule to convert pipe diameters and lengths to square foot surface units.
Example: To install new lagging on 12 linear feet of 5” outside diameter insulated pipe.
12 linear feet x 1.31 (factor for 5 inch diameter pipe) = 15.72 feet, round off to 16 square feet.
| Outside insulation or “bared” pipe diameter in inches |
| Conversion factor to be multiplied by linear feet of pipe |
| 1” |
| 0.26 |
| 1 ½” |
| 0.39 |
| 2” |
| 0.52 |
| 2 ½” |
| 0.65 |
| 3” |
| 0.79 |
| 3 ½” |
| 0.92 |
| 4” |
| 1.05 |
| 4 ½” |
| 1.18 |
| 5” |
| 1.31 |
| 5 ½” |
| 1.44 |
| 6” |
| 1.57 |
| 7” |
| 1.83 |
| 8” |
| 2.10 |
| 9” |
| 2.36 |
| 10” |
| 2.62 |
| 11” |
| 2.88 |
| 12” |
| 3.14 |
| 13” |
| 3.40 |
UNIT PRICE SCHEDULE NOTES
Item No.
1. CONTRACTOR EQUIPMENT AND PERSONNEL SET-UP AND MOVE-OUT AT COMPLETION OF WORK.
The Contractor shall provide the materials, labor and equipment to set-up the "work area" decontamination enclosure system and to move it out at completion of work. This pertains to work requiring general 'work area" isolation as specified herein.
The basis for payment shall be once for each set-up at the facility requiring the decontamination enclosure system.
0. SPECIAL SURFACE CLEANING.
2A. SPECIAL CLEANING OF WALLS AND FLOORS OR DIRECTED SURFACES FOR ASBESTOS FIBER CONTROL . General Requirements: In certain situations, The Contractor will be directed to clean surfaces potentially contaminated with asbestos-containing dust and debris because this dust could cause an airborne exposure hazard if disturbed. Such corrective action may be specified either as a final asbestos control method, or as preliminary exposure control prior to performing another corrective action, as specified herein. Cleaning shall consist of dry vacuuming and/or wet mopping designated surfaces in a manner which minimizes dust generation and effectively rids the surface of visible dust.
b. Vacuum Cleaning Equipment: Vacuum cleaning equipment shall be industrial type designed for such use, equipped with High Efficiency Particulate Absolute (HEPA) exhaust air filters. No other method shall be permitted.
c. Equipment use and inspection: The above equipment shall be properly operated at all times and shall contain no air leaks. The Contractor shall inspect all vacuuming equipment prior to its use, to assure maximum efficiency of HEPA exhaust air filters.
d. Cleaning Procedure: Cleaning shall be accomplished in the following manner:
. Dry vacuum all specified surfaces using HEPA filtered equipment, and a collection attachment which minimizes dust generation.
i. Collect, package, label and dispose of vacuumed material pursuant to Section 02085.
e. Surfaces shall also be wet wiped with amended water :
The basis for payment of this item shall be the area cleaned measure in square feet (determined by the floor and wall surfaces).
2B. SPECIAL CLEANING OF WALLS, FLOORS OR DIRECTED SURFACES FOR FUNGAL SPORE CONTROL . General Requirements: In certain situations, the Contractor will be directed to clean surfaces potentially contaminated with fungal spore growth, dust and debris because this dust could cause an airborne exposure hazard if disturbed. Such corrective action may be specified either as a final fungal sport control method or as preliminary exposure control prior to performing another corrective action, as specified herein. Cleaning shall consist of dry HEPA vacuuming and wet wiping designated surfaces with a mild detergent solution in a manner which minimizes airborne spore generation and effectively rids the surface of visible dust.
b. Vacuum Cleaning Equipment: Vacuum cleaning equipment shall be industrial type designed for such use, equipped with High Efficiency Particulate Absolute (HEPA) exhaust air filters. No other method shall be permitted.
c. Equipment Use and Inspection: The above equipment shall be properly operated at all times and shall contain no air leaks. The Contractor shall inspect al vacuuming equipment prior to its use, to assure maximum efficiency of HEPA exhaust air filters.
d. Cleaning Procedure: Cleaning shall be accomplished in the following manner:
1. Dry vacuum all specified surfaces using HEPA-filtered equipment, and a collection attachment which minimizes dust and airborne spore generation.
2. Contractor shall also wet wipe directed surfaces with a solution of mild detergent and water.
3. Collect, package, label and dispose of vacuumed material pursuant to Section 02085.
The basis for payment of this item shall be the area cleaned measured in square feet (determined by the floor and wall surfaces).
3A-3D. MASKING AND SEALING WITH PLASTIC SHEETING ONLY.
The Contractor shall provide the materials, labor and equipment for masking and sealing the work area walls, floor or ceiling in such a way to guarantee proper sealing of the contaminated work area. In rooms where sprayed-on ceiling material is to be removed, the entire room is to be completely masked and sealed off.
The basis for payment of this item shall be the area measured in square feet (measured by the floor and wall surfaces.)
NOTE :
Item 3A - Single layer. (6-mil) Item 3B - Double layers. (6-mil) Item 3C - Single layer. (4-mil) Item 3D - Double layers. (4-mil)
4A & 4B. MASKING AND SEALING PLASTIC SHEETING AND WOOD STUDS
The Contractor shall provide all the materials, labor and equipment for the erection of the work area enclosure system as specified herein. Such enclosure system shall consist of plastic sheeting and wood studs constructed in such a manner as to guarantee proper sealing of the contaminated work area.
The basis for payment of this item shall be the area measured in square feet as follows:
. In rooms where overhead pipe insulation is to be removed, a tunnel shaped enclosure shall be constructed of studs and sheeting, masked and sealed off. The basis for payment is the area of the tunnel enclosure with floor to ceiling high walls and 6' wide floor, measured in square feet. In no instance shall payment for tunnel enclosures in any room exceed the wall and floor area of the entire room measured in square feet.
b. In rooms where pipes run vertically from floor to ceiling, a tube shaped enclosure shall be constructed of studs and sheeting, masked and sealed off. The basis for payment is the area of the tube enclosure with 4' wide sides measured in square feet.
c. Payment for other enclosures shall be based upon the actual geometric shape measured in square feet.
NOTE:
Item 4A - Single layer (6-mil) Item 4B - Double layers (6-mil)
5. REMOVE ASBESTOS INSULATION FROM BOILER
The Contractor shall provide all materials, labor and equipment for removal of asbestos located on boilers and boiler breeching specified herein.
The basis for payment is the area measured in square feet of insulation removed.
6A & 6B. REMOVE INSULATION FROM DUCTS
The Contractor shall provide all materials, labor and equipment for removal of asbestos located on ducts for all mechanical systems as specified herein.
The basis for payment is the area measured in square feet of insulation removed.
NOTE :
Item 6A. SEMI-RIGID INSULATION.
Item 6B. FLEXIBLE INSULATION.
7A-7C. MOVE EXISTING SUSPENDED ACOUSTICAL CEILING TILE, WHERE GRID SYSTEM IS NOT DISTURBED
7A. REMOVE, CLEAN AND RENSTALL EXISTING SUSPENDED ACOUSTICAL CEILING TILE
The Contractor shall provide all materials, labor and equipment for removing, cleaning and reinstalling existing suspended ceiling tile and the cleaning of the grid and lights. Included under this item is the replacement of damaged ceiling tile where damage occurs during the removal operations.
The basis for payment is the area of ceiling tile cleaned measured in square feet.
7B. REMOVE, CLEAN EXISTING SUSPENDED ACOUSTICAL CEILING TILE.
The Contractor shall provide all materials, labor and equipment for removing, cleaning existing suspended ceiling tile and the cleaning of the grid and lights. The cleaned ceiling tiles may be disposed of as construction debris.
The basis for payment is the area of ceiling tile cleaned measured in square feet.
7C. REMOVE AND CLEAN EXISTING SUSPENDED ACOUSTICAL CEILING TILES AND INSTALL REPLACEMENT TILES.
The Contractor shall provide all materials, labor and equipment for removing and cleaning existing suspended ceiling tile and the cleaning of the grid and lights and installing replacement tiles.
The cleaned ceiling tiles may be disposed of as construction debris.
The basis for payment is the area of ceiling tile cleaned measured in square feet where the GSA is providing the replacement ceiling tiles.
In those cases where the Contractor is providing the replacement tiles the cost of those tiles is to be negotiated with the COR and added to the Delivery Order S-0-W and listed as a "non-scheduled" work item.
7D. REMOVE AND REINSTALL EXISTING SUSPENDED ACOUSTICAL CEILING TILE
The Contractor shall provide all materials, labor, and equipment for removing and reinstalling existing suspended acoustical ceiling tile. The grid and lights are not to be removed.
Included under this item is the replacement of damaged ceiling tile and/or grid and lights, where damage occurs during the removal operations.
The basis for payment is the area of ceiling tile removed measured in square feet.
1. REMOVE, CLEAN AND REINSTALL EXISTING SUSPENDED ACOUSTICAL CEILING TILE COMPLETE WITH GRID AND TILE.
The Contractor shall provide all materials, labor and equipment for removing, cleaning and reinstalling existing suspended ceiling tile and grid system including hanger wire, tees, channels and edge trim. Included under this item is the replacement of damaged ceiling tile where damage occurs during the removal operations and the cleaning of lights.
The basis for payment is the area of ceiling removed and reinstalled measured in square feet.
0. REMOVE EXISTING SUSPENDED ACOUSTICAL CEILING TILE COMPLETE WITH GRID AND TILE.
The Contractor shall provide all materials, labor and equipment for removing existing suspended ceiling tile and grid system including hanger wire, tees, channels and edge trim and shall dispose of all materials removed as asbestos waste. Included under this item is the replacement of damaged ceiling tile where damage occurs during the removal operations.
The basis for payment is the area of ceiling removed and measured in square feet.
10A-10F. REMOVE CEMENTED-ON OR CONCEALED SPLINE CEILING SYSTEM.
The Contractor shall provide all materials, labor and equipment to remove a) cemented-on ceiling tiles (COT) and the sheet rock or plaster backing to which they are cemented or b) the concealed spline ceiling tiles (CST) and their support structure.
The basis for payment is the ceiling area measured in square feet and a determination as to, whether the debris removed may be disposed of as construction debris (CD) or as asbestos waste (AW).
NOTE: This WI disposes of the tiles and their backing systems.
See the attached table which summarizes various combinations for both types of ceiling systems.
| WI No. |
| Types |
| ACM Tile? |
| ACM Mastic? |
| ACM sheet rock or plaster? |
| Is top of ceiling system contaminated? |
| Disposal type |
| 10A |
| COT |
| N |
| N |
| N |
| N |
| CD |
| 10B |
| COT |
| N |
| N |
| N |
| Y |
| CD/AW (1) |
| 10C |
| COT |
COT
COT
Y N Y N Y Y N N N Y/N Y/N Y/N
AW
AW
AW
10D 10E 10F
CST
CST
CST
N Y N N/A N/A N/A N/A N/A N/A N Y Y
CD
AW
AW
NOTES:
10A. Applicable only to COT if NO ACM is affected by the removal.
10B. If only the top of the ceiling system contains ACM, then use CD for COT, and AW for backing material (sheet rock or plaster) if COT is separately removed first. If removed together consider all debris as AW. In other words, for 10B cases use 100% of room area disposal at CD rate for COT and 100% of room area for backing material as AW rate, if COT is separately removed.
10C. If either the COT or the mastic are ACM then dispose of both the tiles and backing material as ACM.
11A-11D. REMOVE ACOUSTICAL ACM FROM CEILING/WALL & BACKFILL BASE SUSFACE, AS REQUIRED (SPRAYED-ON OR TROWLED-ON ACM) The Contractor shall provide all materials, labor and equipment for removal of asbestos acoustic finish located on ceilings and walls.
The basis for payment is the area measured in square feet of insulation removed.
11A. REMOVE ACOUSTICAL ACM ON PLASTER CEILING/WALL.
All the acoustical plaster in the areas specified shall be stripped to the plaster scratch coat except where noted otherwise, using appropriate tools and methods. In all cases, asbestos contaminated materials shall be handled carefully and deliberately. Any unnecessary agitation of the material is strictly prohibited. The use of high RPM power equipment, pressure washers, or hydro-blasters is not acceptable. The scratch coat will be left structurally sound.
11B. REMOVE ACOUSTICAL ACM AND PLASTER CEILING/WALL
For this case Contractor shall remove the ACM and the plaster ceiling/wall.
The debris shall all be handled as asbestos waste.
11C. ACOUSTICAL ACM ON SHEET ROCK CEILING/WALL
If acoustical ACM is being removed from a sheet rock ceiling/wall, then the entire ceiling/wall shall be removed along with the acoustical ACM material. Contractor shall not attempt to remove the acoustical ACM from the sheet rock in an effort to preserve the sheet rock ceiling/wall.
11D. BACKFILLING OF PLASTER CEILINGS/WALLS
“Backfilling" of plaster ceiling/wall for cases when acoustical ACM removal was not scheduled as part of the Delivery Order and only when specified in the Delivery Order itself.
11A. Remove ACM from plaster 11B. Remove ACM and plaster 11C. Remove ACM and sheet rock 11D.”Backfilling”of plaster when specified in D.O.
12A-12O. REMOVE ASBESTOS INSULTION FROM PIPE AND FITTING - USING REGULAR METHOD - (FROM 2" TO 15" PLUS INSULATION OUTER DIAMETERS) The Contractor shall provide all materials, labor and equipment for removal and disposal of asbestos located on pipes and pipe fittings, such as but not limited to elbows, tees, valves, etc. (REGULAR METHOD).
The basis for payment is the length of pipe measured in linear feet where asbestos is removed. Removal of all pipe fittings is included in this linear foot price.
This method of measurement applies to all affected pipes with an outside insulation diameter ranging from 2" to 15" plus.
13A-13O. REMOVE ASBESTOS INSULATION PIPE AND FITTING - USING GLOVE BAG METHOD - (FROM 2" TO 15" PLUS INSULATION OUTER DIAMETERS) The Contractor shall provide all materials, labor and equipment for removal and disposal of asbestos located on pipes and pipe fittings, such as but not limited to elbows, tees, valves, etc. (GLOVEBAG METSOD) .
The basis for payment is the length of pipe measured in linear feet where asbestos is removed. The removal of all pipe fittings is included in this linear foot price.
This method of measurement applies to all affected pipes with an outside insulation diameter ranging from 2” to 15" plus.
14A-14O. REMOVE ASBESTOS INSULATION FROM FITTING ONLY - USING REGULAR METHOD (FROM 2” TO 15” PLUS INSULATION OUTER DIAMETERS) The Contractor shall provide all materials, labor and equipment for removal and disposal of asbestos located on pipe fittings, such as but not limited to elbows, tees, valves, etc. (REGULAR METHOD) .
This method of measurement applies to all affected pipes with outside insulation diameters ranging from 2" to 15" plus.
15A-15O. REMOVE ASBESTOS FROM FITTING ONLY INSULATION - USING GLOVE BAG METHOD - (FROM 2" TO 15" PLUS INSULATION OUTER DIAMETERS) The Contractor shall provide all materials, labor and equipment for removal and disposal of asbestos located on pipe fittings, such as but not limited to elbows, tees, valves, etc. (GLOVEBAG METHOD).
The basis for payment is the number of fittings from which insulation had been removed.
This method of measurement applies to all affected pipes with outside insulation diameters ranging from 2" to 15" plus.
16A & 16B. REMOVE TANK/CHILLER, ETC. INSULATION.
The Contractor shall provide all materials, equipment, and labor to remove insulation from tanks/chillers, etc. and to dispose of as Asbestos Waste (AW).
The basis for payment shall be the tank/chiller, etc., surface areas in square feet.
16A. If one layer or less of wire mesh are inside of insulation 16B. If two or more layers of wire mesh are inside of insulation 17A. REMOVE RIGID ACM PANEL BOARDS FROM CEILINGS, WALLS, COOLING TOWERS, ETC. (INCLUDING TRANSITE PANELS) The Contractor shall provide all materials, labor and equipment to remove rigid ACM Panel Boards from ceilings, walls, cooling towers, etc.
The basis for payment is the surface area of the ACM removed in square feet. All material removed must be disposed of as Asbestos Waste (AW).
17B. REMOVE COOLING TOWER "CORES" (FILLING) MATERIG
The Contractor shall provide materials, labor, and equipment to remove the "Core" (filling) materials inside of cooling towers.
The basis for payment is the volume of the 'Core"(filling) material in cubic feet. All material removed must be disposed of as Asbestos Waste (AW).
18. REMOVE WALL PARTITIONS.
The Contractor shall provide all materials, labor and equipment to remove wall partitions in order to access ACM contained therein or on the walls or ceilings.
The basis for payment shall be the wall, surface area in square feet. All material removed must be disposed of as construction debris (CD) or as asbestos waste (AW) if it contains ACM or is contaminated.
See table below for combinations which are applicable:
| ACM Affected |
| Partition Material |
| Wood |
| Metal |
| N |
| 18A W-NACM |
| 18C M-NACM |
| Y |
| 18B W-ACM |
| 18D M-ACM |
Notes:
N = No ACM affected (NACM) Y = Yes ACM is affected (ACM)
19A-19C. REMOVE VINYL ASBESTOS FLOOR TILE (VAT) AND MASTIC ON CONCRETE FLOORS.
The Contractor shall provide all materials, labor and equipment for the removal of VAT and mastic from concrete floors.
The basis of payment is the floor surface area measured in square feet of VAT and mastic removed.
19A. SINGLE LAYER OF VAT AND MASTIC ON CONCRETE FLOOR.
19B. MULTIPLE LAYERS OF VAT AND MASTIC ON CONCRETE FLOOR TO BE REMOVED.
Where there are multiple layers (i.e. either 2 layers of VAT, mastic or else a layer of felt or "jute type material" as well as one layer of VAT and mastic).
The basis for payment is an additional cost reimbursement to the Contractor for those portions of the floor with "multiple layers".
This is a unit cost per square foot “add on” reimbursement. The unit price indicated is the same regardless of the actual combination of layers of VAT, mastic or felt.
19C. REMOVE ACM MASTIC (ONLY) FROM CONCRETE FLOORS.
The Contractor shall provide all materials, labor and equipment for the removal of ACM mastic from concrete floors.
The basis for payment is the floor surface area measured in square feet, of ACM mastic to be removed.
20A-20D. REMOVE VINYL ASBESTOS TILE AND MASTIC ON WOOD FLOORING.
The Contractor shall provide all materials, labor and equipment to remove VAT and mastic off of wooden flooring.
The basis for payment shall be the floor area with wooden flooring in square feet. This price shall include removal and disposal of all materials removed as Asbestos Waste (this includes VAT and mastic in all cases and wooden flooring as well for case 20B Work Item).
20A. SINGLE LAYER OF VAT AND MASTIC ON WOODEN FLOORS.
No wooden flooring is removed and all feasible mastic has been removed off of the wooden surface.
20B. SINGLE LAYER OF VAT AND MASTIC ON WOODEN FLOORS.
If it is necessary to remove some or all of the wooden flooring as well as the VAT and mastic, all of the VAT and mastic and wooden flooring removed shall be disposed of as Asbestos Waste.
Note: In those cases when only a portion of the floor area is wood and is removed, an apportionment must be made of floor areas which were not removed per WI 20A and those floor areas removed per WI 20B.
20C. MULTIPLE LAYERS OF VAT, MASTIC ON WOODEN FLOORS TO BE REMOVED.
Where there are multiple layers (i.e. either 2 layers of VAT, mastic or else a layer of felt or "jute type material" as well as one layer of VAT and mastic).
The basis for payment is an additional cost reimbursement to the Contractor for those portions of the floor with “multiple layers".
This is a cost per square foot "add on” reimbursement. The unit price indicated is the same regardless of the actual combination of layers of VAT, mastic or felt.
20D. REMOVE ACM MASTIC (ONLY) FROM WOODEN FLOOR.
The Contractor shall provide all materials, labor and equipment for the removal of ACM mastic from wooden floors.
The basis for payment is the floor surface area measured in square feet, of ACM mastic to be removed.
21. REMOVE CARPETING FROM FLOOR.
The Contractor shall provide all materials, labor and equipment for the removal of carpeting from floors.
The basis for payment is the floor area measured in square feet and a determination as to whether the carpeting may be disposed of as construction debris (CD) or must be disposed of as asbestos waste (AW) due to significant quantities of ACM in either the floor tile or mastic and/or carpet ACM mastic to hold the carpeting in place.
See attached table which summarizes the various work item carpeting combinations:
NOTES:
1. Small amounts of tile or tile and mastic is pulled up with carpeting or carpet tile (below cutoff limits).
2. Large amounts of tile or tile and mastic is pulled up with carpeting or carpet tile (above cutoff limits).
3. RACM (Removed Asbestos Contaminated Material) cutoff limit is a total of 160 square feet.
22. REMOVE ASBESTOS INSULATION OR FIRE PROOFING FROM BEAMS, COLUMNS, JOISTS OR OTHER STRUCTURAL SURFACES. LEAVE SURFACES READY FOR NEW FIREPROOFING.
The Contractor shall provide all materials, labor and equipment for removal of sprayed-on asbestos located on beams, columns, joists or other structural surfaces, plus any over spray. (2 feet either side of structural member is considered 'normal" for over spray).
After all asbestos materials have been removed, surfaces should be nylon brushed, wet wiped with amended water and sprayed with a minimum of two coats of encapsulant.
1. If all asbestos materials cannot be removed, the Contractor shall seal off the remaining materials with airtight enclosures. Contractor shall also designate the locations of the ACM left in place on building floor plan drawings for the Buildings Manager's ACM Records.
2. After completing installation of enclosures they shall all be nylon brushed, wet wiped and sprayed with a minimum of two coats of encapsulant.
3. All of these steps should be taken by the Contractor prior to attempting to take any final clearance air monitoring of any work area in which asbestos materials had been left in-place.
The basis for payment is the surface area measured in square feet of insulation removed.
23A-23D. REMOVE BUILT-UP ROOFING.
The Contractor shall provide all materials, labor and equipment to remove roofing felts and roofing flashing.
The basis of payment is the roof area measured in square feet and a determination as to whether the debris may be disposed of as Construction Debris (CD) or as Asbestos Waste (AH).
24. INSTALL NEW SUSPENDED ACOUSTICAL CEILING TILE COMPLETE WITH GRID AND TILE.
The Contractor shall provide all materials, labor and equipment for installing suspended ceiling tile and grid system including hanger wire, tees, channels and edge trim complete.
The basis for payment is the area of ceiling tiles installed measured in square feet.
25A & 25B. REINSULATE HVAC DUCTWORK.
The Contractor shall provide all materials, labor and equipment for installation of new insulating material on ducts for mechanical systems.
The basic for payment is the area measured in square feet of HVAC duct insulation in place.
25A. SEMI-RIGID INSULATION.
Semi-Rigid insulation shall be 1-1/2" thick, 3 lb. density, factory fiberglass reinforced kraft paper, applied mechanically fastened to duct at not less than 3" from each edge or corner of the board, then 12" on center.
25B. FLEXIBLE INSULATION.
Flexible .insulation shall be 2" thick, 3 lb. density fiberglass. Apply insulation with all joints tightly butted. Secure insulation to ductwork with adhesive in 6-inch wide strips on 12 inch centers. Staple laps of jacket with outward clinching staples and seal with foil scrim kraft (FSK) tape. For ductwork over 24-inches on horizontal duct runs, provide pins, washers and clips. Use pins on sides of vertical ductwork being insulated. Space pins and clips on 18 inch centers and not more than 18 inches from duct corners. Carry insulation over standing seams and trapeze type hangers. Install speed washers with pins and pin trimmed washer. Sagging of flexible duct insulation will not be permitted. Cut off protruding ends or pins after clips are secured and sealed with coating compound conforming Mil. Spec. MIL-C-19565, Type II for inside work. For warm air ducts, overlap insulation not less than 2 inches at joints and secure the laps with outward clinch staples on 4-inch centers. In cold air ducts, vapor seal all joints and staple as specified.
26. REINSULATE TANKS, CHILLERS, ETC.
The Contractor shall provide all materials, labor and equipment to reinsulated tanks, chillers, etc.
The basis for payment shall be the tank, chiller, etc., surface areas in square feet plus a set-up cost of $300.00 per tank/chiller.
26A. Base amount - Set up cost 26B. t = 1" thick 26C. t = 1-1/2" thick
27. REPLACE BOILER OR BREECHING INSULATION COMPLETE WITH 1-1/2" THICK CALCIUM SILICATE BLOCK, METAL BFLNDING, 1/2" THICK INSULATING CEMENT OVER WIRE MESH, LAGGING CLOTH AND PAINTED FINISH. SEE A-13.
The Contractor shall provide all materials, labor and equipment for installation of new insulating material on boilers and boiler breeching.
The basis for payment is the area measure in square feet of boiler insulation in place.
28. INSTALL 1" SPRAYED ON ACOUSTICAL MATERIAL ON CEILINGS OR WALLS.
The Contract shall provide all materials, labor and equipment for spraying on 1" acoustical material on bare (no existing textured material) existing ceilings or walls.
The basis for payment is the surface area covered by sprayed-on material measured in square feet.
29A-29E. INSTALL 1,2,3, OR 4 HR. FIRE-RATED SPRAYED-ON OR FIREPROOFING ON UNDERSIDE OF DECKS ABOVE AND ON BEAMS AND COLUMNS. WORK INCLUDES DUST BARRIERS, TESTING AND CLEAN-UPS.
The Contractor shall provide all materials, labor and equipment for the installation of sprayed-on fireproofing materials located on ceilings, beams, columns and other structural members, thickness as specified herein.
The basis for payment is the area measured in square feet of ceiling or structural member covered in place.
The Contractor shall have a factory representative present at the job site. This representative will oversee the mixing and application of the manufacturer's raw materials.
. Prior to the application of the sprayed-on F/P, the Factory Representative, and the "approved applier ("i.e. the installer"] of the F/P and the IQ Contractor should all agree as to which UL Design number in the Underwriters Laboratories, Inc., current "Fire Resistance Directory" was appropriate for each of the different roof system and floor system locations at: which the F/P material is to be applied.
B. If no structural drawings are available the IQ Contractor should conduct some investigative surveys including core drilling if necessary of typical roof systems and floor system locations to help determine which structural system configurations are actually present.
C. With this information concerning the structural systems, the appropriate UL Designs can be identified in the book and then the required insulation thickness can be determined for the fire rating specified in the DO for that particular roof or floor system configuration at that location.
D. At the completion of the application, the factory representative will be required to certify that for each roof and floor system configuration on which the F/P was sprayed, that the specified FR (Fire Rating) in hours was achieved.
This requires that the factory representative check:
1. Verify the mix used by the Installer.
2. Verify that the minimum thickness of F/P has bee applied on each different surface.
3. Verify that the F/P density is 15 pcf.
4. Verify that the mix has had a "color" added to differentiate the new ACM free F/P from the ACM F/P which has been removed as part of the project.
29A. 1-hr. fire-rated F/P 29B. 2-hr. fire-rated F/P 29C. 3-hr. fire-rated F/P 29D. 4-hr. fire-rated F/P 29E. Application of F/P Sealant
30. REMOVE AND REINSTALL EXISTING LIGHT FIXTURE.
The Contractor shall provide all materials, labor and equipment for removing existing light fixture, cleaning, protective wrapping, safe storage and finally replacing fixture in their original location and in working order. Damage to fixture during these operations shall be repaired by the Contractor under this item.
The basis for payment will be once for each fitting, or in the case of continuous fluorescent light fixtures, each l ' x 4' or 2' x 4' unit.
31. REHANG SUSPENDED CEILING LIGHTS.
Re-hang lights as required when ceiling systems are removed per W18. Additional wires are to be installed as required in order to leave the light fixtures reasonably level.
The basis of payment is the number of lights requiring support and relieving.
Note: The lights shall be level enough to satisfy Buildings Manager and the COR.
32A-321. REPLACE ASBESTOS PIPE AND FITTING INSULATION WITH 1" FIBERGLASS INSULATION, WITH ALL SERVICE JACKET (FIBERGLASS 25 ASJ/SSL) - FOR 1" THRU 8" PIPE SIZES.
The Contractor shall provide all materials, labor and equipment for installation of new Fiberglass insulation and jacket on pipes and fittings.
The basis for payment is the measurement per linear foot of pipe insulation in place 33A-33I. REPLACE ASBESTOS PIPE AND FITTING INSULATION COMPLETE WITH 1-1/2” FIBERGLASS INSULATION, WITH ALL SERIVCE JACKET (FIBERGLASS 25 ASJ/SSL) – FOR 1” THROUGH 8” PIPE SIZES.
The Contractor shall provide all materials, labor and equipment for installation of new Fiberglass insulation and jacket on pipes and fittings.
The basis for payment is the measurement per linear foot of pipe insulation in place.
34A-34H. REPLACE ASBESTOS PIPE AND FITTING INSULATION COMPLETE WITH 2" FIBERGLASS INSULATION, WITH ALL SERVICE JACKET (FIBERGLASS 25 ASJ/SSL) - FOR 1" THRU 8” PIPE SIZES.
The Contractor shall provide all materials, labor and equipment for installation of new Fiberglass insulation and jacket on pipes and fittings.
The basis for payment is the measurement per linear foot of pipe insulation in place.
35A-351. REPLACE ASBESTOS PIPE FITTING INSULATION COMPLETE WITH 1" FIBERGLASS INSUTATION, WITH ALL SERVICE JACKET. (FIBERGLASS 25 ASJ/SSL) - FOR 1" THRU 8" PIPE SIZES.
The Contractor shall provide all materials, labor and equipment for installation of new Fiberglass insulation and jacket on fittings.
The basis for payment is the number of fittings re-insulated and . without flanges and
a. with flanges added unit price 36A-361. REPLACE ASBESTOS FIPE FITTING INSULATION COMPLETE WITH 1-1/2" FIBERGLASS INSUSLATION, WITH ALL SERVICE JACKET (FIBERGLASS 25 ASJ/SSL) - FOR 1" THRU 8” PIPE SIZES.
The Contractor shall provide all materials, labor and equipment for installation of new Fiberglass insulation and jacket on fittings.
The basis for payment is the number of fittings re-insulated and . without flanges and
a. with flanges added unit price 37A-37H. REPLACE ASBESTOS PIPE FITTING INSULRTION COMPLETE WITH 2" FIBERGLASS INSULATION WITH ALL SERVICE JACKE (FIBERGLASS 25 ASJ/SSL) - FOR 1" THRU 8" PIPE SIZES.
The Contractor shall provide all materials, labor and equipment for installation of new Fiberglass insulation and jacket on fittings.
The basis for payment is the number of fittings re-insulated and . without flanges and
a. with flanges added unit price
38A-38C. SELECTIVE DEMOLITION - CUT OPENING IN PARTITION.
The Contractor shall provide all materials, labor and equipment for selective demolition of cutting opening in gypsum board, plaster or masonry partitions.
The basis for payment shall be per each opening made.
39A-39D. SELECTIVE DEMOLITION - CUT HOLE IN PARTITION.
The Contractor shall provide all materials, labor and equipment for selective demolition of cutting a hole in masonry or concrete partition, wall or floor slab.
40A-40C. SELECTIVE DEMOLITION - CUT OPENING IN CEILING.
The Contractor shall provide all materials, labor and equipment for selective demolition of cutting a hole in gypsum board, plaster or acoustical tile ceiling.
41. INSTALL A 5/8" GYPSUM BOARD ENCLOSURE TO SEAL OFF ASBESTOS CONTAINING MATERIALS.
The Contractor shall proved materials, labor and equipment for enclosing and sealing (caulking) off of asbestos containing materials located on ceilings, structural members, pipes, in pipe chases, out in the open, etc., using 5/8'' gypsum board. The enclosure shall also be sprayed with an encapsulant as a last means of achieving an airtight enclosure.
The basis for payment is the surface area measured in square feet of the 5/8" gypsum board required to accomplish the enclosure. This figure is intended to include the cost of framing, installing gypsum board (including bedding and taping), caulking and encapsulating the enclosure.
42. SPRAY ENCAPSULATING SEALANT ON INSULATED (ACOUSTICAL OR FIREPROOFING) SURFACES INCLUDING CEILINGS, BEAMS, COLUMNS, JOISTS, DECK, WALLS AND DUCTS. 2 COATS @ 75 SQUARE FEET PER GALLON. SEE DRAWING A-14.
The Contractor shall provide all materials, labor and equipment for spraying encapsulating material on existing asbestos containing fireproofing and/or other texturing material located on ceilings, beams, columns, joists, deck, walls and ducts. The basis for payment is the surface area covered by encapsulant with minimum thickness and/or penetration as specified in square feet.
Sealant must be declared compatible with the sprayed-on fireproofing by the manufacturer of the fire-proofing, material which is being sealed.
43. SPRAY A "LOCKDOWN" MIST ON "BARED" SURFACES AND ON CONTAINMENT ENCLOSURE POLY.
The Contractor shall provide all materials, labor and equipment for spraying an encapsulating “mist" on "bared" surfaces where ACM had been removed and on containment enclosures to "lockdown" those fibers which are still present but which may not be visible to the naked eye. (VAT and mastic removals are excepted from this requirement).
The basis for payment is the surface area in square feet to be covered by the encapsulating “mist".
This is not intended as a "full bore" encapsulating such as that specified in Work Item 42 above for Sprayed-On Fireproofing materials.
44. INSTALL BENT METAL PLATE BUMPER GUARD AROUND PIPING AND INSULATION. SEE DRAWING A-15.
The Contractor shall provide all materials, labor and equipment for the installation of bent metal bumper guards around piping and insulation.
The basis for payment is the weight of the steel sheet measure in pounds.
45. GLOVEBAG. SEE DRAWING A-16.
The Contractor shall provide all materials, labor and equipment for removal of asbestos by the glovebag method as specified herein. The glovebag method may be used in lieu of masking the work area. It applies where asbestos containing material is found only at pipe fittings, elbows, tees, valves, etc., and other isolated areas. Work shall include the installation, use and disposal of the glovebag and the removal of the asbestos containing material.
The basis for payment shall be once for each fitting, etc., requiring the glovebag removal method.
46. PAINTING OF NEW MATERIALS AND REPAIRED SURFACES WITH 2-COATS.
The Contractor shall provide all materials for painting the outside covering on newly installed insulation. The paint color shall match the existing color.
The basis for payment is the measurement per square foot of area painted (two coats).
47. STENCILED LABELS.
The Contractor shall provide all materials, labor and equipment for painting stenciled or sticking/stapling on non-ACM identification labels on all newly insulated pipes.
The basis for payment shall be per each painted or "stuck on" stencil in place. Locate them as required by not more than 30 linear feet between labels.
48. TAKE BULK SAMPLES AND ANALYZE THEM BY POLARIZED LIGHT MICROSCOPY AND PROVIDE A REPORT.
The Contractor shall provide all materials, labor and equipment, and in compliance with EPA and OSHA, for taking and analyzing Bulk samples as specified herein. Such bulk samples shall be taken by a Certified Industrial Hygienist or a person working under the direct supervision of a Certified IH who works for an Independent Test Laboratory which has been approved by the Contracting Officer. Analysis must be performed at the Laboratory.
The basis for payment shall be the number of bulk samples taken and analyzed with submission of test results.
49. TAKE AIR SAMPLES AND ANALYZE THEM BY PHASE CONTRAST MICROSCOPY AND PROVIDE A REPORT.
The Contractor shall provide all materials, labor and equipment, and in compliance with EPA and OSHA, for taking and analyzing air samples as specified herein. Such air samples shall be taken by a Certified Industrial Hygienist or a person working under the direct supervision of a Certified Industrial Hygienist. Air monitoring samples shall be analyzed using the PCM method by an IH or air-monitoring Technician who works for an Independent Testing Laboratory qualified for accreditation by the American Industrial Hygiene Association and approved by the Contracting Officer. PCM analyses should be performed “on site" within two hours after completing the sample. Note: This applies to OSHA personnel samples as well.
The basis for payment shall be each air sample taken and analyzed with submission of test results. Contractors will not be paid for air sample blanks, for "overloaded" cassette air samples or for quality control "re-reads".
GSA does not reimburse Contractors or A/E’s who take an excess number of air samples during a work shift.
The Contractor will not be paid for air samples until as satisfactory summary air monitoring test report has been received and approved. The report shall include all of the elements described in Section 02085.
49A. AIR MONITORING SAMPLES – COLLETION ONLY
The Contractor shall provide all materials, labor and equipment for taking air samples only. Samples taken shall be by a qualified individual.
The Contractor shall have the M&I contractor, at the location, perform the subsequent analysis. GSA will reimburse the M&I contractor to perform the air sample analyses.
The basis for payment shall be each air sample taken. The contractor will not be paid for air samples until a satisfactory summary report of the personnel air samples taken, including raw data sheets, has been received and approved.
50. TAKE AIR MONITORING SANPLES AND ANALYZE THEM BY TRANSMISSION ELECTRON MICROSCOPE (TEM) AND REPORT.
The Contractor shall provide all materials, labor and equipment, and in compliance with EPA and OSHA, for taking and analyzing air-monitoring samples as specified herein. Such air samples shall be taken by a Certified Industrial Hygienist or a person working under the direct supervision of a Certified Industrial Hygienist. Air samples shall be analyzed using the TEM method by an Independent Testing Laboratory accredited by the American Industrial Hygiene Association and approved by the Contracting Officer. TEM analysis must be performed "at the laboratory" within forty eight hours unless otherwise specified in the Delivery Order.
The basis for payment shall be each air sample taken and analyzed with submission of test results.
51. PATCH HOLES IN PIPE, DUCT OR BOILER INSULATION, SEE DRAWING A-1.
The Contractor shall provide all materials, labor and equipment for patching all holes, cracks and splits in existing pipe, boiler and duct insulation.
The basis for payment is the area patched measured in square feet.
52. PATCH CRACKS AND SPLITS IN PIPE LAGGING. SEE DRAWING A-2.
The Contractor shall provide all materials, labor and equipment for patching all cracks and splits in pipe lagging.
The basis for payment is the area patched measured in square feet.
53. REPAIR CRACK IN PIPE INSULATION. SEE DRAWING A-3.
The Contractor shall provide all materials, labor and equipment for repairing cracks in pipe insulation.
The basis for payment is the area repaired measured in square feet.
54. SEAL EXPOSSD ENDS OF PIPE INSULAION AT FITTINGS, ELBOWS AND WALL OPENINGS. MORTAR BULLET. SEE DRAWING A-4.
The Contractor shall provide all materials, labor and equipment to form mortar bullets to pipe insulations at fittings, elbows and wall openings.
The basis for payment is the area of bullet ends measured in square feet.
55. REPAIR BOILER LAGGING. SEE DRWING A-5.
The Contractor shall provide all materials, labor and equipment for repairing boiler lagging.
The basis for payment shall be the area repaired measured in square feet.
56. REPAIR BOILER AND/OR BREECHING INSULATION. SEE DRAWING A-6.
The Contractor shall provide all materials, labor and equipment for repairing boiler and/or breeching insulation.
The basis for payment shall be the area repaired measure in square feet.
57. REPAIR INSULATION AT PIPE SUPPORT OR PIPE HANGER. SEE DRAWING A- 7.
The Contractor shall provide all materials, labor and equipment for repairing insulation at pipe support or pipe hanger.
58. REPAIR OF MISSING PIPE INSULATION. SEE DRAWING A-8
The Contractor shall provide all materials, labor and equipment for repairing missing pipe insulation.
59. REPAIR DUCT INSULATION. SEE DRAWING A-9.
The Contractor shall provide.al1 materials, labor and equipment for repairing duct insulation.
60. REPAIR PIPE ELBOW OR PIPE FITTING USING FIBERGLASS INSULATION AND PVC PRE-FORMED COVER. SEE DRAWING A-10.
The Contractor shall provide all materials, labor and equipment for installation of new Fiberglass insulation including P.V.C. pre-formed covers at pipe-fittings such as elbows, tees, 45’s, etc.
The basis for payment under this item of work shall be for each pipe fitting enclosed.
61. REPAIR PIPE INSULATION AND INSTALL P.V.C. COVER ON PIPING. SEE DRAWING A-11.
The Contractor shall provide all materials, labor and equipment for repairing pipe insulation and enclosing with P.V.C. pipe cover.
The basis for payment is the measurement per square foot of P.V.C. cover in place.
62. REPAIR PIPE JNSLTLATION AND INSTALL CORRUGATED METAL JACKETING. SEE DRAWING A-12.
The Contractor shall provide all materials, labor and equipment for repairing pipe insulation and installing corrugated metal jacketing over insulation on piping.
The basis for payment is the surface area of corrugated metal measured in square feet.
63A & 63B. PROVIDE SCAFFOLDING
The Contractor shall provide all materials, labor and equipment for providing access to ACM at various heights.
The basis for payment is the number of 5 ft. wide by 7 ft. long, by 9 ft. high rolling scaffolding required.
These prices include all costs to the Contractor. These include, but are not limited to: rental, pick-up, transport, setting up, tearing down, cleaning, transport, and delivery back to scaffold rental place, etc.
The basis for payment is the volume (in C.C.F.) for Steel Tubular scaffolding required.
63A. ROLLING SCAFFOLDING
63B. STEEL-TUBULAR STATIONARY SCAFFOLDING.
64. RECLEARING ALL FIXED AND MOVABLE FURNITURE, EQUIPMENT, ETC. AND RE-ESTABLISHING AFTER WORK COMPLETION.
The Contractor shall provide all materials, labor and equipment for "clearing out" all furniture and equipment, as specified, in Delivery Order.
This same furniture and equipment, etc., is to be "returned" back where it came from after the particular Delivery Order work requiring the relocation (e.g. Asbestos Abatement), has been completed.
NOTE:
In some cases the Contractor may be instructed to relocate these items to another location in the building.
The basis for payment shall be the floor area "cleared" measured in square feet. This unit price includes both "clearing out" and "moving back" efforts.
Room occupants will he strongly urged to clear their desks and other furniture of personal items, to eliminate these being damaged during the asbestos abatement. In addition, they are also strongly urged to remove all pictures, plaques, awards, etc., which are mounted to the walls for the very same reason.
65A & 65F. ADDITIONAL COPIES OF SUMMARY TEST REPORTS.
The Contractor shall provide additional copies of the Summary Air Monitoring Test Reports for the Delivery Order. NOTE: These are copies over and above the 3* copies specified in the Basic IQ Contract Document.
| No. of Extra Copies |
| Small DO |
| Medium DO |
| Large DO |
| 1 |
| 65A |
| 65C |
| 65E |
| 2 |
| 65B |
| 65D |
| 65F |
Small air samples <50;
Medium> 50 but <250;
Large> 250
* 1 for 7PMCP Project File, 1 for 7PMS, and 1 for 7PMF Buildings Manager.
66. REPAIR DAMAGED FLAT SURFACES ON HVAC DUCT LINERS.
The Contractor shall provide all materials, labor and equipment for the repair of damaged HVAC Duct semi-rigid insulation.
The repair shall consist of removing damaged insulation, "backfilling" damaged areas, and then applying Fosters 30-36 Chill Seal and Fiberglass cloth over the previously damaged areas.
The basis for payment shall be the area repaired in square feet.
67. REMOVE ASPHALT PLANKS AND MASTIC FROM FLOORS
The Contractor shall provide all materials, labor and equipment to remove 12"x24"x1/2" asphalt planks and mastic from floors. They shall be disposed of as Asbestos Waste.
The basis for payment is the number of square feet of floor area from which the asphalt planks and mastic are to be removed.
68. INSTALL CANVAS WRAP O K R F1P.C DUCTING INSULATION OR OVER PIPE INSULATION.
The Contractor shall provide all materials, labor and equipment to install canvas wrap over ducting or piping insulation.
The basis for payment is the number of square feet of surface area which is required.
69. INSTALL "CHEAP-0" OVER BARED COLD WATER OR BARED CHILLED WATER LINES.
The Contractor shall provide all materials, labor and equipment to install "Cheap-O Wrap" over bared Cold Water and Chilled Water piping to minimize condensation forming on these pipes and thereby minimizing dripping of water on the floors.
The basis for payment is the number of square feet of surface area which is to be wrapped.
70. REMOVAL OF AHU DUCTNG AND AHU FAN UNIT GASKETS.
The Contractor shall provide all materials, labor and equipment to remove gaskets on AHU Ducting and AHU Fan Units.
The basis for payment is the number of linear feet of gaskets being removed.
71A & 71B. REMOVE COVE MOULDING.
The Contractor shall provide all materials, labor and equipment to remove cove moulding from baseboards or from wall surfaces.
1. The Contractor shall take extreme caution in removing these mouldings to eliminate damage to the baseboard or wall surface finish.
0. Damages to baseboards or wall surfaces shall be the responsibility of the Contractor to repair or to pay for repair.
71A. 4" cove moulding 71B. 6" cove moulding 72A-72H. INSTALL 1/2" PLYWOOD WAFER BOARD SHEETING ON FLOORS/CARPETS TO PROTECT THEM DURING ASBESTOS ABATEMENT.
The Contractor shall provide all, materials, labor and equipment to install plywood/wafer sheeting on floor/carpeting to protect it from damage during asbestos abatement.
The basis of payment is the number of square feet of floor/carpeting surface areas to be protected.
72A. 1/2" Plywood uncaulked between seams 72B. 5/8" Plywood uncaulked between seams 72C. 3/4" Plywood uncaulked between seams
720. 1/2" Plywood caulked between seams 72E. 5/8" Plywood caulked between seams 72F. 3/4" Plywood caulked between seams 72G. 1/2" Wafer board uncaulked between seams 72H. 1/2" Wafer board caulked between seams
73. INSTALL A ROOFING FELT LAYER ON RAISED FLOOR SURFACES TO PROTECT THEM DURING ASBESTOS ABATEMENT.
The Contractor shall provide all materials, labor and equipment to install roofing felt layer on raised-floor surfaces to protect them from damage during asbestos abatement.
The basis for payment is the number of square feet of raised-floor surface area to be protected.
74. INSTALL CORRUGATED CARDBOARD TO PROTECT CARPETING.
The Contractor shall provide all materials, labor and equipment to install corrugated cardboard on carpeting to minimize damage to the carpeting during asbestos…