Amendment_006_to_Solicitation.pdf
PDF 40 MB Posted
- Solicitation number
- GS05P17GBC0003
About this file
Amendment to Solicitation 006
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Amendment__014.pdf | ||
| Amendment__0013.pdf | ||
| Amendment_0010.pdf | ||
| Amendment_to_Solicitation_009.pdf | ||
| Amendment008.pdf | ||
| Amendment_007_to_Solicitation.pdf | ||
| Amendment_004_to_Solicitation.pdf | ||
| Amendment_to_Solicitation_005.pdf | ||
| Amendment_003.pdf | ||
| Pre-proposal_sheet.docx | DOCX document | |
| Amendment_001.pdf |
Show all 11
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Offers must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended, by one of the following methods:
(a) By completing items 8 and 15, and returning or (c) By separate letter or electronic communication which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by letter or electronic communication, provided each letter or electronic communication makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.
E. IMPORTANT: Contractor is not is required to sign this document and return copies to the issuing office.
AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT 1. CONTRACT ID CODE
2. AMENDMENT/MODIFICATION NUMBER 3. EFFECTIVE DATE 4. REQUISITION/PURCHASE REQUISITION NUMBER 5. PROJECT NUMBER (If applicable)
7. ADMINISTERED BY (If other than Item 6) CODE
STANDARD FORM 30 (REV. 11/2016)
Prescribed by GSA FAR (48 CFR) 53.243
FACILITY CODE
9A. AMENDMENT OF SOLICITATION NUMBER
9B. DATED (SEE ITEM 11)
10A. MODIFICATION OF CONTRACT/ORDER NUMBER
10B. DATED (SEE ITEM 13)
11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS
The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offers is extended. is not extended.
12. ACCOUNTING AND APPROPRIATION DATA (If required) copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted;
13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS.
IT MODIFIES THE CONTRACT/ORDER NUMBER AS DESCRIBED IN ITEM 14.
CHECK ONE A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE CONTRACT ORDER
NUMBER IN ITEM 10A.
B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation data, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(b).
C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:
D. OTHER (Specify type of modification and authority)
Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.
15C. DATE SIGNED
15A. NAME AND TITLE OF SIGNER (Type or print)
16C. DATE SIGNED
16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)
14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)
PAGE OF PAGES
6. ISSUED BY CODE
8. NAME AND ADDRESS OF CONTRACTOR (Number, street, county, State and ZIP Code) (X)
CODE
15B. CONTRACTOR/OFFEROR
(Signature of person authorized to sign)
16B. UNITED STATES OF AMERICA
(Signature of Contracting Officer)
Previous edition unusable
5P!QCE-CH
GS-05-P-17-GB-C-0001 -Construction Manager as Constructor, for the John C. Kluczynski Federal Building Tenant Office Buildout, Amendment 006 The above referenced solicitation hereby incorporates updated drawings for EEOC.
5P1QCE-CH
Acquisition Management Division 230 S. Dearborn St.
Room 3300 Chicago, IL 60604
Acquisition Management Division 230 S. Dearborn St.
Room 3300 Chicago, IL 60604
GS05P17GBC0003
08/16/2017
07/18/2017
INSTRUCTIONS (Back Page):
Instructions for items other than those that are self-explanatory, are as follows:
Item 1 (Contract ID Code). Insert the contract type identification code that appears in the title block of the contract being modified.
Item 3 (Effective date).
(1)
(2)
(3)
(4)
(5)
For a solicitation amendment, change order, or administrative change, the effective date shall be the issue date of the amendment, change order, or administrative change.
For a supplemental agreement, the effective date shall be the date agreed to by the contracting parties.
For a modification issued as an initial or confirming notice of termination for the convenience of the Government, the effective date and the modification number of the confirming notice shall be the same as the effective date and modification number of the initial notice.
For a modification converting a termination for default to a termination for the convenience of the Government, the effective date shall be the same as the effective date of the termination for default.
For a modification confirming the contracting officer's determination of the amount due in settlement of a contract termination, the effective date shall be the same as the effective date of the initial decision.
(a)
(b)
(c)
(d)
(e)
(f)
Item 6 (Issued By). Insert the name and address of the issuing office. If applicable, insert the appropriate issuing office code in the code block.
Item 8 (Name and Address of Contractor). For modifications to a contract or order, enter the contractor's name, address, and code as shown in the original contract or order, unless changed by this or a previous modification.
Items 9, (Amendment of Solicitation Number - Dated), and 10, (Modification of Contract/Order Number - Dated). Check the appropriate box and in the corresponding blanks insert the number and date of the original solicitation, contract, or order.
Item 12 (Accounting and Appropriation Data).
When appropriate, indicate the impact of the modification on each affected accounting classification by inserting one of the following entries:
(2) Accounting classification Net decrease $
Include subject matter or short title of solicitation/contract where feasible.
Item 16B. The contracting officer's signature is not required on solicitation amendments. The contracting officer's signature is normally affixed last on supplemental agreements.
(i)
NOTE: If there are changes to multiple accounting classifications that cannot be placed in block 12, insert an asterisk and the words "See continuation sheet".
Item 13. Check the appropriate box to indicate the type of modification. Insert in the corresponding blank the authority under which the modification is issued. Check whether or not contractor must sign this document. (See FAR 43.103.)
Item 14 (Description of Amendment/Modification).
Organize amendments or modifications under the appropriate Uniform Contract Format (UCF) section headings from the applicable solicitation or contract. The UCF table of contents, however, shall not be set forth in this document.
Indicate the impact of the modification on the overall total contract price by inserting one of the following entries:
(i) Total contract price increased by $
(ii) Total contract price decreased by $
(iii) Total contract price unchanged.
State reason for modification.
When removing, reinstating, or adding funds, identify the contract items and accounting classifications.
(g)
(h)
When the SF 30 is used to reflect a determination by the contracting officer of the amount due in settlement of a contract terminated for the convenience of the Government, the entry in Item 14 of the modification may be limited to --
(i) A reference to the letter determination; and
(ii) A statement of the net amount determined to be due in settlement of the contract.
(1)
(2)
(3)
(4)
(5)
(6)
STANDARD FORM 30 (REV. 11/2016) BACK
(1) Accounting classification Net increase $
RE
VI
SI
ON
B
LO
CK
CO
NT
RA
CT
DE
SI
GN
ER
ID
EN
TIF
IC
AT
IO
N
ST
AM
P
OR
S
EA
L
OW
NE
R
ID
EN
TIF
IC
AT
IO
N
BU
ILD
IN
G
PR
OJ
EC
T
SH
EE
T
P R
O P
E R
T Y
O F
T H
E U
N
IT
E D
S T
A T
E S
G O
V E
R N
M E
N T
F
O R
O F
F
IC
IA
L U
S E
O N
L Y
D
O N
O T
R E
M O
V E
T H
IS
N
O T
IC
E
P
R O
P E
R L Y
D E
S T
R O
Y D
O C
U M
E N
T S
W H
E N
N O
L O
N G
E R
N E
E D
E D
General Services Administration Public Buildings
Service Great Lakes Region 5
Professional Services Division John C. Kluczynski Federal Building 230 South Dearborn Street Chicago, IL 60604
CONST. CONTRACT NO.
DELIVER ORDER NO.
A/E CONTRACT NO.
BUILDING NAME
ADDRESS
CITY, STATE, ZIP
BUILDING NO.
PROJECT TITLE
GSA PROJECT NO.
SUBMISSION STAGE
SUBMISSION DATE
DRAWN BY
CHECKED BY
FLOOR NO.
DISCIPLINE
PLAN TYPE
SHEET NUMBER
AND FILENAME
KE
Y
PL
AN
GR
AP
HI
C
SC
AL
E
/1
/2
:3 :0
P
M
G000
18TH &29TH FLOOR
2010101
O. ORTEGA
J. STRYKER
230 S. DEARBORN ST.
N.A.
GENERAL
N.A.
08/14/2017
ADDENDUM 1
EEOC
GS-05P-15-FA-D-XXXX
CHICAGO, IL 60604
IL0236FC
JOHN C. KLUCZYNSKI FEDERAL BUILDING
PROPERTY OF THE UNITED STATES GOVERNMENT
COPYING, DISSEMINATION, OR DISTRIBUTION OF
THESE DRAWINGS, PLANS, OR SPECIFICATIONS TO
UNAUTHORIZED PERSONS IS PROHIBITED
Do not remove this notice Properly destroy documents when no longer needed
GENERAL SERVICES ADMINISTRATION
JOHN C. KLUCZYNSKI FEDERAL BUILDING
230 SOUTH DEARBORN STREET
18TH & 29TH FLOOR EEOC
ADDENDUM 1
CHICAGO, ILLINOIS 60604
GSA PROJECT CONTROL NO.: EP-GS-P-05-15-FD-7000
AUGUST 14, 2017
GENERAL SERVICES ADMINISTRATION
230 SOUTH DEARBORN STREET CHICAGO, ILLINOIS 60604
MARK DATE DESCRIPTION
north
1. ALL WORK SHALL CONFORM TO THE REQUIREMENTS OF THE 2015 INTERNATIONAL BUILDING
CODE; THE LATEST NATIONAL ELECTRIC CODE; GSA FACILITY STANDARDS PBS-P100 2015;
LATEST NFPA 13, 14, 72 & 101; UNDERWRITERS LABORATORY AND FACTORY MUTUAL
STANDARDS (WHERE APPLICABLE). THE WORK SHALL MEET THE PROVISIONS OF U.F.A.S &
TITLE III OF THE AMERICANS WITH DISABILITIES ACT, AND "ADA ACCESSIBILITY GUIDELINES
FOR BUILDINGS AND FACILITIES".
2. THE CONTRACTOR SHALL PROTECT ALL EXISTING SITE AND BUILDING ELEMENTS FROM
DAMAGE DUE TO THE DEMOLITION AND CONSTRUCTION OPERATIONS, AND REPAIR OR
REPLACE ELEMENTS WHICH ARE TO REMAIN, AND WHERE DAMAGED DURING THE WORK, TO
THE SATISFACTION OF THE CONTRACTING OFFICER, AT THE CONTRACTOR'S EXPENSE. THE
CONTRACTOR SHALL MAKE THE CONTRACTING OFFICER AWARE OF ANY EXISTING DAMAGES
ON THE FLOOR. IT IS THE CONTRACTOR'S RESPONSIBILITY TO SCHEDULE THIS SURVEY WITH THE CONTRACTING OFFICER.
3. ALL DIMENSIONS SHALL BE VERIFIED IN THE FIELD BEFORE PROCEEDING WITH THE WORK.
NOTIFY THE CONTRACTING OFFICER IN WRITING OF ANY DISCREPANCIES.
4. UNLESS NOTED OTHERWISE, ALL TYPICAL WALLS AND PARTITIONS ARE DIMENSIONED TO
THE FACE OF THE WALL.
5. UNLESS NOTED OR DIMENSIONED OTHERWISE, ALL DOORS ARE LOCATED BY THEIR JAMB
DETAIL RELATIVE TO ADJACENT WALLS AND PARTITIONS. REFER TO SHEET A901 FOR JAMB
DETAILS.
6. ALL PIPING, DUCTS, CONDUITS, ETC. THAT PENETRATE RATED FLOOR SLABS AND WALLS
SHALL BE INSTALLED IN A MANNER THAT WILL PRESERVE THE FIRE INTEGRITY OF THE
FLOOR OR WALL. AS PER A U.L. TESTED ASSEMBLY.
7. ALL INTERIOR FINISHES SHALL BE:
CORRIDORS CLASS II
SMOKE DEVELOPED: ≤ 100 {PBS-PQ100.1 (7-9)}
FLAME SPREAD:26 - 75
OFFICES CLASS III
SMOKE DEVELOPED:≤ 200 {PBS-PQ100.1 (7-9)}
FLAME SPREAD:76 - 200
17. INSPECTION BY THE CONTRACTOR: THE CONTRACTOR AKNOWLEDGES AND AGREES THAT HE HAS INDIVISIBLE AND CONTRACTUAL OBLIGATION TO THE OWNER TO MAKE HIS ON INSPECTIONS OF HIS WORK AT ALL STAGES OF CONSTRUCTION; AND SHALL SUPERVISE PERFORMANCE OF WORK IN SUCH
MANNER AS TO ENABLE HIM TO CERTIFY AT ALL TIMES THAT WALL WORK HAS BEEN EXECUTED
STRICTLY IN ACCORDANCE WITH THE METHODS AND REGULATIONS GOVERNING THE EXECUTION OF THE
WORK.
18. THE CONTRACTOR SHALL NOT ALLOW HAZARDOUS CONDITIONS OR PUBLIC NUISANCES TO DEVELOP OR
PERSIST IN PERFORMANCE OF THE WORK. THE CONTRACTOR SHALL INSTALL AND MAINTAIN
APPROPRIATE SAFETY BARRIERS OR TEMPORARY PARTITIONS AS REQUIRED BY GOVERNING AGENCIES AND AT ALL LOCATIONS WHERE THE GENERAL PUBLIC MAY HAVE ACCESS TO, OR COME IN CONTACT
WITH THE PROJECT SITE LIMITS.
19. ALL REFUSE AND DEBRIS SHALL BE REMOVED FROM THE SITE AND LEGALLY DISPOSED OF BY THE
CONTRACTOR.
20. CONTRACTOR SHALL REVIEW DRAWINGS FOR COORDINATION PRIOR TO COMMENCEMENT OF WORK.
EACH TRADE IS RESPONSIBLE FOR THE COORDINATION OF ALL RELATED DIVISIONS WHOSE WORK
INTERFACES WITH THEIR OWN.
21. THOROUGHLY REVIEW ALL PLANS AND SPECIFICATIOINS. VERIFY ALL DIMENSIONS AND CONDITIONS
BEFORE STARTING WORK. NOTIFY THE ARCHITECT OF ANY DISCREPANCIES.
22. PROVIDE CATHODIC ISOLATION BETWEEN DISSIMILAR MATERIALS.
23. MAINTAIN WORK AREAS FREE OF DEBRIS ACCUMULATION. KEEP WORK AREAS NEAT AND ORDERLY AND
ALL MEANS OF EGRESS ROUTES MAINTAINED FREE AND CLEAR AT ALL TIMES.
24. IT IS THE CONTRACTOR'S RESPONSIBILITY TO VISIT THE SITE AND DETERMINE THE EXACT EXTENT OF WORK, COORDINATION, DEMOLITION , TEMPORARY CONSTRUCTION, TEMPORARY FACILITIES, UTILITIES, ETC. NECESSARY TO COMPLETE
8'-0"
AxDxX
AXXX
AXXX
+20'-0"
TOP OF STEEL
A
ACOUSTICAL CEILING TILE
ARCHITECTURAL ABBREVIATIONS
COORDINATING OFFICER'S
HIGH PRESSURE LAMINATE
CONCRETE MASONRY UNIT HEATING VENTILATING
PARTITION \ TARGET
INTERIOR ELEVATION
REVISION TARGET
ELEVATION
NUMBER
SHEET NUMBER
AREA OF REVISION
REVISION NUMBER
HORIZONTAL
GLASS, GLAZING
HARDWARE
HOLLOW METAL
GYPSUM BOARD
HEIGHT
HIGH POINT
HT(H)
HP
HVAC
GYP. BD.
HORIZ
H
HM
HDW
HIGH
FLEXIBLE
FEET (FOOT)
FOOTING
FLOOR
FINISH
FOUNDATION
GENERAL CONTRACTOR
FURNISH, FURNITURE
GENERAL
GALVANIZED
GAUGE
FTG
GC
GL
GEN
GALV
FURN
GA
FIN
FDN
FT(')
FLEX
FLR
ITEM BEING REFERENCED
DATUM ELEVATION
DRAWING NUMBER, TITLE, SCALE
SHEET NUMBER
DETAIL NUMBER
SECTION NUMBER
SHEET NUMBER
ELEVATION TARGET
DOOR TARGET
ROOM NAME / NUMBER
ROOM NAME
ROOM NUMBER
DIMENSIONS
DETAIL REFERENCE
WINDOW TARGET
EXPANSION, EXPOSED
ENCLOSURE
EXHAUST
EXISTING, EX'G
ELEVATOR
EQUAL
EQUIPMENT
EXISTING
FLOOR DRAIN
EXPANSION JOINT
EXTERIOR
EXP
EXIST
FD
EXT
EJ
ENCLOS
ELEV
EXH
EQUIP
EQ
EXIST
DIAMETER
DIMENSION
DRAWING(S)
DRINKING FOUNTAIN
DETAIL
ELEVATION
ELECTRICAL
DOWEL
DWG(S)
EL
ELECT
EA
DWL
EACH
DET
DR
DN
DIM
DIA
DF
DOWN
DOOR
COVED VINYL BASE
COORDINATE
CONTRACTOR
CONTINUOUS
CERAMIC TILE
CENTER
DEPRESSION, DEPRESS
CYLINDER
DEEP (DEPTH)
DOUBLE
DEMOLITION
DEP
DEMO
DBL
D
CYL
CONT
CVB
COORD
CONTR
CTR
CT
CHECKED
CONTROL JOINT
CENTER LINE
CEILING
CLEAR
BOTTOM
BASEMENT
COLUMN
CONCRETE
CLOSET
CLR
CLG
CONC
COL
CLOS
BSMT
BOT
CL
CJ
CHK'D
GRAPHIC SYMBOLS
NO PREFIX:
SEE LIST ON
SAME SHEET
KEYNOTE:
DRAWING SPECIFIC
PARTIAL SECTION
"D" PREFIX:
SEE 27-A-0.1
KEYNOTES:
GENERAL
DEMOLITION
PROJECT KEYNOTE SYSTEM
RENOVATION
"A" PREFIX:
SEE 27-A-0.1
KEYNOTES:
GENERAL
ANCHOR, ANCHORAGE
BUILDING
ASSOCIATED
APPROVED
ARCHITECTURAL
ANODIZED
AUTOMATIC
AUXILIARY
AVERAGE
BOARD
BLOCK
BLDG
BD
AVG
AUX
BLK
ANOD
ARCH
APP'D
ANCH
ASSOC
AUTO
ADJACENT, ADJUSTABLE
ABOVE FINISHED FLOOR
ACOUSTICAL
ACCESS DOOR
AIR CONDITIONER
ALUMINUM
ACT
ADJ
AFF
AD
ACOUST
ALUM
A/C
AT
(ALL DISCIPLINES)
AND AIR-CONDITIONING
DIMENSION IN FT'-IN"
CPT CARPET
COR
REPRESENTATIVE
GYPSUM BOARDGPDW
H.P.L.
CMU
WOOD BLOCKING
WOOD
ALUMINUM
STEEL
CONCRETE MASONRY UNITS
BRICK ACOUSTICAL TILE
GLASS
STEEL
STAINLESS STEEL
CONCRETE
PLASTER / SAND / MORTAR / CEILING TILE
RIGID INSULATION
BATT INSULATION
WEST ADAMS STREET
WEST JACKSON BOULEVARD
S O
U T
H D
E A
R B
O R
N S
T R
E E
T
S O
U T
H C
L A
R K
S T
R E
E T
U.S. POST
OFFICE BUILDING EVERETT
McKINLEY
DIRKSEN
BUILDING
JOHN C. KLUCZYNSKI
FEDERAL BUILDING
LOCATION PLAN
TUBULAR STEEL OR TOP OF STEEL
TEMPERED, TEMPORARY, TEMPERATURE
WORKING POINT
WITHOUT
WIDTH, WIDE
WEIGHT
WATER CLOSET
UNDERWRITERS LABORATORIES
VERTICAL
UNLESS NOTED OTHERWISE
TYPICAL
THROUGH
THICK, THICKNESS
SUSPEND, SUSPENDED
TOP, THICK
TOP AND BOTTOM
W/I
W/O
WP
WD
WITHIN
WOOD
VERT
W
W/
WT
WC
WITH
UL
TYP
TS
THRU
UNO
SUSP
TEMP
T&B
T
THK
REPLACE
RELOCATE, RELOCATED
REQUIRE, REQUIRED
RADIUS, RISER
REFLECTED, REFERENCE, REFER
REVISE, REVISION
ROOFING
RIGHT HAND
SPECIFICATION
SEALANT
STRUCTURAL (STRUCTURE)
ROUGH OPENING
SOLID CORE WOOD
SCHEDULE
SIMILAR
SQUARE
STAINLESS STEEL
STANDARD
STRUCTURAL CLAY TILE
SPEC(S)
STD
STRUC
STL
SS
SQ
STEEL
SCHED
SCT
SEAL
SIM
SHT SHEET
RH
ROOFG
REV
SCWD
RO
RM ROOM
REF
R
REPL
RELOC
REQ
PROVIDE
PLYWOOD
NO CHANGE
PREFABRICATED
PLUMBING
POUNDS PER SQUARE FOOT
POUNDS PER SQUARE INCH
PLASTER
PAINT, POINT
PARTITION
OPPOSITE
NOT APPLICABLE
MOUNTING HEIGHT
NOT IN CONTRACT
NOT TO SCALE
NUMBER
NOMINAL
ON CENTER
OUTSIDE DIAMETER
OVERHEAD
PR
PROV
PREFAB
PT
PSI
PSF
PAIR
PART
OPP
PLYWD
PLAS
PL
PLMBG
PLATE
OC
NOM
NO,#
OH
OD
MTL
N/A
MTG HT
NC
NTS
NIC
METAL
POUND, POUNDS
LENGTH
LAMINATE
LAVATORY
LIGHTWEIGHT CONCRETE
MATERIAL
MAXIMUM
MEDIUM DENSITY PANEL BOARD
MEDIUM
MINIMUM
MISCELLANEOUS
MASONRY OPENING
MOUNTED
MANUFACTURER
INSULATE, INSULATION
INFORMATION
INTERIOR
MIN
MED
MANUF
MTD
MO
MISC
LTWT CONC
LB(S)
MATL
M.D.P.
MAX
JT
LAV
LAM
L
INSUL
INT
JOINT
INFO
IN(") INCH
ARCHITECTURAL SYMBOLS
GENERAL PROJECT NOTES AND CONDITIONS
TFP TEXTURE FINISHED PAINT
VCT VINYL COMPOSITION TILE
IRWC IMPACT RESISTANT WALL COVERING
VINYL WALL COVERINGVWC
VINYL BASEVB
MECH MECHANICAL
JOHN C. KLUCZYNSKI FEDERAL
BUILDING 230 SOUTH DEARBORN
STREET CHICAGO, ILLINOIS
VENDINGVND
DRAWING SPECIFIC KEYNOTES WILL BE FOUND ON EACH SHEET
37TH FLOOR PLAN
1/8"=1'-0"
OFFICE
NOTE: REFER
TO SHT. A-601
FOR PARTITION
TYPES
PARTITION TYPE
EXIST.
PARTITION
TO REMAIN
EXIST.
PARTITION
TO BE
DEMOLISHED
NEW PARTITION
EXISTING
DOOR TO
REMAIN
NEW
DOOR &
NUMBER
DOOR TO
BE
DEMOLISHED
8. UNLESS NOTED OTHERWISE, WHERE CONFLICTS ARISE BETWEEN THE PLANS, DETAILS AND
SCHEDULES, THE CONTRACTING OFFICER WILL MAKE A WRITTEN INTERPRETATION.
9. PROVIDE FOR THE REMOVAL, CAPPING AND PLUGGING OF EXISTING TELEPHONE AND ELECTRIC FLOOR OUTLETS, AT FLOOR LEVEL. FURTHER INFORMATION IS GIVEN IN THE ELECTRICAL DRAWINGS.
10. FILL WITH APPROPRIATE MATERIAL ALL SCREW HOLES EXPOSED IN EXISTING CURTAIN WALL MULLIONS WHERE EXISTING INTERIOR PARTITIONS HAVE BEEN REMOVED, CLEAN AND RESTORE FINISH (PAINT) TO
MATCH THE ADJACENT, UNDAMAGED, PAINTED MULLIONS.
11. THE CONTRACTOR IS TO RESTORE THE FINISH ON ANY MULLIONS THAT ARE IN DISREPAIR AS A PRE- EXISTING CONDITION, PRIOR TO THE START OF THE WORK; TO MATCH THE ADJACENT, UNDAMAGED PAINTED MULLIONS. THE CONTRACTING OFFICER TOGETHER WITH THE CONTRACTOR, WILL SURVEY THESE AREAS AND IDENTIFY THE MULLIONS WHICH WILL REQUIRE REMEDIAL ACTION, BEFORE WORK
BEGINS ON EACH FLOOR.
12. ALL EXISTING SURFACES, SCHEDULED TO REMAIN AND WHICH ARE WITHIN THE AREA OF WORK, SHALL BE PATCHED AND REPAIRED, IN A MANNER SUITABLE FOR THE SCHEDULED FINISH. REMOVE, REPLACE AND PATCH ANY LOOSE, DETERIORATED OR WATER DAMAGED PLASTER.
13. ALL EXISTING MINIBLINDS ARE TO REMAIN. EACH ONE IS TO BE RAISED AND PROTECTED
THROUGHOUT COSTRUCTION BY BEING NEATLY WRAPPED WITH PLASTIC.
14. FOR ANY OPEN FLAME STEEL WELDING OR TORCH CUTTING, GSA REQUIRES CONTRACTOR TO OBTAIN BURN PERMIT FROM GSA BUILDING MANAGER AND PROVIDE FIRE WATCH. FIRE WATCH IS MANDATED
TO BE CURRENT BUILDING MAINTENANCE/SECURITY COMPANY. ALL COSTS ASSOCIATED BY
CONTRACTOR.
15. THE CONTRACTOR SHALL COORDINATE INTERRUPTION OF ANY BUILDING UTILITIES WITH THE GSA AND
BUILDING MANAGER AT LEAST 72 HOURS BEFORE INTERRUPTION IS TO TAKE PLACE.
16. THE CONTRACTOR ALONE SHALL BE RESPOSIBLE OF THE SAFETY AND ADEQUACY OF HIS PLANT, APPLIANCES, AND METHODS. HE SHALL ERECT AND PROPERLY MAINTAIN AT ALL TIMES AS REQUIRED BY THE CONDITIONS AND PROCESS OF THE WORK, PROPER SAFEGUARDS FOR THE PROTECTION OF
WORKMEN, OWNER, AND OWNER'S PROPERTY. CONTRACTOR SHALL POST DANGER WARNINGS
AGAINST HAZARDS CREATED BY THE CONSTRUCTION OPERATIONS. HE SHALL DESIGNATE A
RESPONSIBLE MEMBER OF HIS ORGANIZATION ON THE WORK. WHOSE DUTY SHALL BE THE PREVENTION OF ACCIDENTS. IN ABSENCE OF NOTICE CONTRARY, FIELD IN WRITING TO THE OWNER, THE PERSON
WOULD BE THE SUPERINTENDENT OF THE CONTRACTOR.
AXXX
AXXX
WINDOW NUMBER#
HARDWOODHDWD
RE
VI
SI
ON
B
LO
CK
CO
NT
RA
CT
DE
SI
GN
ER
ID
EN
TIF
IC
AT
IO
N
ST
AM
P
OR
S
EA
L
OW
NE
R
ID
EN
TIF
IC
AT
IO
N
BU
ILD
IN
G
PR
OJ
EC
T
SH
EE
T
P R
O P
E R
T Y
O F
T H
E U
N
IT
E D
S T
A T
E S
G O
V E
R N
M E
N T
F
O R
O F
F
IC
IA
L U
S E
O N
L Y
D
O N
O T
R E
M O
V E
T H
IS
N
O T
IC
E
P
R O
P E
R L Y
D E
S T
R O
Y D
O C
U M
E N
T S
W H
E N
N O
L O
N G
E R
N E
E D
E D
General Services Administration Public Buildings
Service Great Lakes Region 5
Professional Services Division John C. Kluczynski Federal Building 230 South Dearborn Street Chicago, IL 60604
CONST. CONTRACT NO.
DELIVER ORDER NO.
A/E CONTRACT NO.
BUILDING NAME
ADDRESS
CITY, STATE, ZIP
BUILDING NO.
PROJECT TITLE
GSA PROJECT NO.
SUBMISSION STAGE
SUBMISSION DATE
DRAWN BY
CHECKED BY
FLOOR NO.
DISCIPLINE
PLAN TYPE
SHEET NUMBER
AND FILENAME
KE
Y
PL
AN
GR
AP
HI
C
SC
AL
E
/1
/2
:3 :0
P
M
G001
18TH &29TH FLOOR
2010101
S. MORENO
J. STRYKER
230 S. DEARBORN ST.
N.A.
GENERAL
N.A.
08/14/2017
ADDENDUM 1
EEOC
GS-05P-15-FA-D-XXXX
CHICAGO, IL 60604
IL0236FC
JOHN C. KLUCZYNSKI FEDERAL BUILDING
DRAWING INDEX
SHEET NO. SHEET NAME
10 MECHANICAL
M001 MECHANICAL GENERAL NOTES, LEGENDS &ABBREVIATIONS
MD118 MECHANICAL DEMO PLAN - LEVEL 18
MD119 MECHANICAL DEMO PLAN - LEVEL 29
MH118 MECHANICAL HVAC PLAN - LEVEL 18
MH119 MECHANICAL HVAC PLAN - LEVEL 29
MH501 MECHANICAL HVAC SCHEDULES
MH502 MECHANICAL HVAC SCHEDULES
MH601 MECHANICAL HVAC DETAILS
11 PLUMBING
P001 PLUMBING GENERAL NOTES, ABBREVIATIONS, & LEGEND
PD118 PLUMBING DEMO PLAN - LEVEL 18
PD119 PLUMBING DEMO PLAN - LEVEL 29
P118 PLUMBING PLAN - LEVEL 18
P119 PLUMBING PLAN - LEVEL 29
12 FIRE PROTECTION
F001 FIRE PROTECTION GENERAL NOTES, ABBREVIATIONS, &
LEGEND
F118 FIRE PROTECTION PLAN - LEVEL 18
F119 FIRE PROTECTION PLAN - LEVEL 29
16 ELECTRICAL
E001 ELECTRICAL NOTES, ABBREV, AND SYMBOLS
ED118 ELECTRICAL DEMO PLAN - LEVEL 18
ED119 ELECTRICAL DEMO PLAN - LEVEL 29
EL118 LIGHTING PLAN - LEVEL 18
EL119 LIGHTING PLAN - LEVEL 29
EP118 POWER PLAN - LEVEL 18
EP119 POWER PLAN - LEVEL 29
EP601 ELECTRICAL PANEL SCHEDULE
EP602 ELECTRICAL PANEL SCHEDULE
FA118 FIRE ALARM PLAN - LEVEL 18
FA119 FIRE ALARM PLAN - LEVEL 29
17 TELECOM
T001 TELECOM NOTES, ABBREV, AND SYMBOLS
TD118 TELECOM DEMO PLAN - LEVEL 18
TD119 TELECOM DEMO PLAN - LEVEL 29
T118 TELECOM PLAN - LEVEL 18
T119 TELECOM PLAN - LEVEL 29
T401 TELECOM ENLARGED PLANS
T501 TELECOM DETAILS
T601 TELECOM SCHEDULES AND DIAGRAMS
DRAWING INDEX
SHEET NO. SHEET NAME
00 GENERAL
G000 COVER SHEET
G001 GENERAL NOTES, DRAWING INDEX, ABBREV, AND SYMBOLS
G101 LIFE SAFETY DIAGRAMS
06 ARCHITECTURAL
A101 OVERALL ISOMETRIC - LEVEL 18
A102 OVERALL ISOMETRIC - LEVEL 29
AD118 DEMO FLOOR PLAN - LEVEL 18
AD119 DEMO FLOOR PLAN - LEVEL 29
AD318 DEMO RCP - LEVEL 18
AD319 DEMO RCP - LEVEL 29
A118 FLOOR PLAN - LEVEL 18
A119 FLOOR PLAN - LEVEL 29
A120 FOLDING PANEL PARTITION FRAMING PLAN AND DETAILS
A128 FLOOR FINISH PLAN - LEVEL 18
A129 FLOOR FINISH PLAN - LEVEL 29
A138 FLOOR FURNITURE PLAN - LEVEL 18
A139 FLOOR FURNITURE PLAN - LEVEL 29
A318 RCP - LEVEL 18
A319 RCP - LEVEL 29
A420 CASEWORK DETAILS
A421 ENLARGED PLANS
A422 ENLARGED PLANS
A601 INTERIOR ELEVATIONS
A602 INTERIOR ELEVATIONS
A604 INTERIOR ELEVATIONS
A901 DOOR & FRAME DETAILS
A902 DOOR & HARDWARE SCHEDULE
A903 DOOR & HARDWARE SCHEDULE
A904 DOOR & HARDWARE SCHEDULE
A905 DOOR & WINDOW DETAILS
A910 ROOM FINISH SCHEDULE
A911 ROOM FINISH SCHEDULE
A912 ROOM FINISH SCHEDULE
A913 PARTITION DETAILS
A940 CEILING DETAILS
S
SS
DN
D C B AEFGHJ
TWO HOUR RATED WALL
1. ALL ROOMS MUST BE SEPARATED FROM EACH OTHER BY 1-HOUR FIRE
RESISTANCE RATED WALLS.
2. CORRIDORD MUST HAVE A MINIMUM FIRE RESISTANCE RATING OF AT LEAST 1/2-
HOUR.
3. SEE REFLECTED CEILING PLANS FOR EXIT LIGHT LOCATIONS.
4. ALL CORRIDORS SHALL BE OF SMOKE TIGHT CONSTRUCTION.
LIFE SAFETY LEGEND
CAP
STAIR CAPACITY
EXIT STAIR DOOR
TWENTY-NINTH FLOOR
OCCUPANT LOAD
NOTES:
FT
DISTANCE IN FT TO EXIT
CODE ANALYSIS
NOTE: THE MOST STRINGENT APPLICABLE CODE REQUIREMENTS ARE LISTED BELOW.
CODE REQUIREMENT SECTION
USE GROUP
B (BUSINESS) IBC 304.1
THE BUILDING IS USED PRIMARILY AS OFFICES AND OTHER USES COMPLYING
WITH THE B USE GROUP CLASSIFICATION. THE 9TH FLOOR IS COMPRISED OF
OFFICE AND ACCESSORY USES. THE ENTIRE FLOOR IS SPRINKLERED.
REQUIRED SEPARATION
ELECTRICAL ROOMS NFPA
CONSTRUCTION TYPE
1-B IBC 602.2
IBC TABLE 601
THE BUILDING STRUCTURE IS PRIMARILY A STRUCTURAL STEEL FRAMING WITH
+/- 6" THICK FLOOR AND ROOF SLABS. THE BUILDING EXTERIOR WALLS ARE
PRIMARILY STEEL AND GLASS.
ALLOWABLE HEIGHT AND AREA
ALLOWABLE HEIGHT: 46 STORIES IBC TABLE 503
ALLOWABLE AREA: UNLIMITED
ACTUAL HEIGHT: 43 STORIES
ACTUAL AREA: 26,553 SF, 18 FLOOR\ 26,553 SF, 29 FLOOR
ACTUAL SCOPE AREA: 18,688 SF, 18 FLOOR \ 8,632 SF, 29 FLOOR
THE BUILDING IS 43 STORIES WITH A FOOTPRINT OF 26,048 SQUARE FEET
DEFINED BY THE PERIMETER COLUMNS.
HIGH-RISE BUILDINGS
THE REQUIREMENTS OF SECTION 403 FOR HIGH-RISE BUILDINGS APPLIES, THEIBC 403.1
RENOVATION TO THE 18TH AND 29TH FLOORS WILL BE EQUIPPED WITH
1. AUTOMATIC SPRINKLER SYSTEM IBC 403.3
2. AUTOMATIC FIRE DETECTION IBC 403.4.1
3. EMERGENCY VOICE/ALARM COMMUNICATIONS SYSTEM IBC 403.4.4
4. FIRE DEPARTMENT COMMUNICATIONS SYSTEM IBC 403.4.6
5. STANDBY POWER IBC 403.4.8
6. EMERGENCY POWER SYSTEMS IBC 403.4.9
THE EXISTING SPRINKLER SYSTEM AND OTHER SAFETY SYSTEMS WILL BE
RECONFIGURED FOR THE NEW RENOVATION.
OCCUPANT LOAD
OCCUPANT LOAD FOR THE ENTIRE 18TH FLOOR IS AS FOLLOWS:
1. BUSINESS AREAS P-100
17,197 SF AT 150 FT² GROSS \ OCCUPANT = 114 OCCUPANTSTABLE 7.4.4
2. BREAK ROOM (>450 FT²) P-100
455 SF AT 15 FT² NET PER OCCUPANT = 30 OCCUPANTSTABLE 7.4.4
3. CONFERENCE\MEETING\TRAINING\WAITING ROOMS (ANY SIZE)P-100
2,120 SF AT 15 FT² NET PER OCCUPANT = 142 OCCUPANTS TABLE 7.4.4
4. STORAGE NFPA 101
1,102 SF AT 500 FT² PER OCCUPANT = 2 OCCUPANTS TABLE 7.3.1.2
5. ACCESSORY STORAGE AREAS, MECHANICAL, EQUIPMENT ROOMIBC
1,611 SF AT 300 GROSS FT² PER OCCUPANT = 5 OCCUPANTSTABLE 1004.1.2
18TH FLOOR TOTAL OCCUPANTS = 294 OCCUPANTS
OCCUPANT LOAD FOR THE ENTIRE 29TH FLOOR IS AS FOLLOWS:
1. BUSINESS AREAS P-100
19,845 SF AT 150 SF GROSS \ OCCUPANT = 133 OCCUPANTSTABLE 7.44
2. BREAK ROOM \ PANTRY (<450 FT²) P-100
306 SF AT 30 FT² GROSS PER OCCUPANT = 10 OCCUPANTSTABLE 7.4.4
3. CONFERENCE ROOM\MEETING ROOM\TRAINING ROOM (ANY SIZE)P-100
1,784 SF AT 15 NET PER OCCUPANT = 119 OCCUPANTS TABLE 7.4.4
4. STORAGE ROOM NFPA
202 SF AT 500 FT² PER OCCUPANT = 0 OCCUPANTS TABLE 7.3.1.2
5. ACCESSORY STORAGE AREAS, MECHANICAL, EQUIPMENT ROOMIBC
561 SF AT 300 GROSS FT² PER OCCUPANT = 2 OCCUPANTSTABLE 1004.1.2
29TH FLOOR TOTAL OCCUPANTS = 264 OCCUPANTS
ONE HOUR RATED WALL
EIGHT-TEENTH FLOOR
OCCUPANT LOAD
BUSINESS
BREAK ROOM (<450 FT²)
BREAKDOWN
EXIT CAPACITY
1:150
1:15
OCC.
OCC.360
SMOKE BARRIER
CONFERENCE\TRAINING ROOM\
WAITING SPACE
1:15 142
EGRESS WIDTH
18TH FLOOR ALLOWABLE EGRESS WIDTH FOR BUILDING WITH SPRINKLER SYSTEM:
CAPACITY FACTOR FOR BUSINESS USE GROUP = 0.2" NFPA 101
TABLE 7.3.3.1
MINIMUM CORRIDOR WIDTH CALCULATION:
294 OCCUPANTS / 2 EXITS = 147 OCCUPANTS NFPA 101
7.3.3
147 OCCUPANTS AT 0.2" PER OCCUPANT = 29"
NARROWEST CORRIDOR IN EXISTING PORTION OF 18TH FLOOR IS 72"
NARROWEST CORRIDOR IN RENOVATED PORTION OF 18TH FLOOR IS 60"
29TH FLOOR ALLOWABLE EGRESS WIDTH FOR BUILDING WITH SPRINKLER SYSTEM:
CAPACITY FACTOR FOR BUSINESS USE GROUP = 0.2" NFPA 101
TABLE 7.3.3.1
MINIMUM CORRIDOR WIDTH CALCULATION:
264 OCCUPANTS / 2 EXITS = 132 OCCUPANTS NFPA 101
7.3.3
132 OCCUPANTS AT 0.2" PER OCCUPANT = 26"
NARROWEST CORRIDOR IN EXISTING PORTION OF 29TH FLOOR IS 72"
NARROWEST CORRIDOR IN RENOVATED PORTION OF 29TH FLOOR IS 51"
DEAD END LIMIT
DEAD-END CORRIDORS SHALL NOT EXCEED 50' - 0" NFPA 101
39.2.5.2
COMMON PATH OF EGRESS TRAVEL
COMMON PATH OF EGRESS TRAVEL SHALL NOT EXCEED 100 FEET NFPA 101
(PER EXCEPTION 1) 39.2.5.3.1
SPACES PERMITTED TO HAVE ONE MEANS OF EGRESS
SPACE WHERE EXIT ACCESS TRAVEL IS LESS THAN OR EQUAL TO 100' - 0" NFPA 101
COMMON PATH OF TRAVEL TO AN AREA WHERE ACCESS TO TWO DIFFERENT 39.2.4.2
EXITS CAN BE ACHIEVED (PER EXCEPTION 1)
MAXIMUM EXIT ACCESS TRAVEL DISTANCE
FOR SPRINKLERED BUILDINGS = 300' - 0" (PER EXCEPTION) NFPA 101
39.2.6
CORRIDOR FIRE RESISTANCE RATING
CORRIDORS ARE REQUIRED TO HAVE A 1-HOUR RATING PER NFPA 101, NFPA 101
HOWEVER, PER PBS-P100 SECTION 7.4.1, THIS REQUIREMENT IS OVERRIDDEN 7.1.3.1
AND CORRIDORS ARE NOT REQUIRED TO BE RATED
MINIMUM NUMBER OF EXITS REQUIRED
MINIMUM 2 EXITS REQUIRED ON THE 18TH AND 29TH FLOOR NFPA 101
39.2.4.1
EXISTING 18TH AND 29TH FLOORS EA CONTAIN 2 EXISTING EXITS
MINIMUM NUMBER OF PLUMBING FIXTURES REQUIRED
1. WATER CLOSETS: CHICAGO
1 REQUIRED FOR THE FIRST 10 OCCUPANTS, BUILDING
2 REQUIRED FOR THE NEXT 11-25 OCCUPANTS AND CODE TABLE
1 ADDITIONAL FOR EA. 25 IN EXCESS OF 25 18-29-403.1
18TH FLOOR: 294 OCCUPANTS - 147 MEN \ 147 WOMEN
13 WATER CLOSETS REQUIRED - 7 PER SEX
4 FOR WOMEN EXISTING
4 FOR MEN EXISTING
29TH FLOOR: 264 OCCUPANTS - 132 MEN \ 132 WOMEN
11 WATER CLOSETS REQUIRED - 6 PER SEX
4 FOR WOMEN EXISTING
4 FOR MEN EXISTING
2. LAVATORIES:
1 PER 40 OCCUPANTS REQUIRED
18TH FLOOR
7 LAVATORIES REQUIRED - 4 PER SEX
4 FOR WOMEN EXISTING
4 FOR MEN EXISTING
1 NEW LAVATORY IN TENANT SPACE
29TH FLOOR
7 LAVATORIES REQUIRED - 4 PER SEX
4 FOR WOMEN EXISTING
4 FOR MEN EXISTING
3. DRINKING FOUNTAINS:
1 PER 100 OCCUPANTS REQUIRED
3 DF's REQ'D ON THE 18TH AND 29TH FLOORS
2 EXISTING ON THE 18TH AND 29TH FLOORS
4. SERVICE SINKS:
1 REQUIRED
1 SERVICE SINK EXISTING AT 18TH AND 29TH FLOORS
FOUR HOUR RATED WALL
TOTAL
STORAGE ROOM 21:500
BREAKDOWN
ACCESSORY STORAGE AREAS,
MECHANICAL EQUIPMENT ROOM
51:300
BUSINESS
BREAK ROOM \ PANTRY (<450 FT²)
EXIT CAPACITY
1:150
1:15
OCC.
OCC.360
CONFERENCE\TRAINING ROOM\
WAITING SPACE
1:15 119
TOTAL
STORAGE ROOM 01:500
ACCESSORY STORAGE AREAS,
MECHANICAL EQUIPMENT ROOM
21:300
J H G F E D C B A
4/5
3/4
CAP
180 CAP
FT
FT
FT
FT
J H G F E D C B A
4/5
3/4
CAP
CAP
FT
FT
FT
FT
KEY PLAN
N.T.S.
0 16' 32'
1/16"=1'-0"
RE
VI
SI
ON
B
LO
CK
CO
NT
RA
CT
DE
SI
GN
ER
ID
EN
TIF
IC
AT
IO
N
ST
AM
P
OR
S
EA
L
OW
NE
R
ID
EN
TIF
IC
AT
IO
N
BU
ILD
IN
G
PR
OJ
EC
T
SH
EE
T
P R
O P
E R
T Y
O F
T H
E U
N
IT
E D
S T
A T
E S
G O
V E
R N
M E
N T
F
O R
O F
F
IC
IA
L U
S E
O N
L Y
D
O N
O T
R E
M O
V E
T H
IS
N
O T
IC
E
P
R O
P E
R L Y
D E
S T
R O
Y D
O C
U M
E N
T S
W H
E N
N O
L O
N G
E R
N E
E D
E D
General Services Administration Public Buildings
Service Great Lakes Region 5
Professional Services Division John C. Kluczynski Federal Building 230 South Dearborn Street Chicago, IL 60604
CONST. CONTRACT NO.
DELIVER ORDER NO.
A/E CONTRACT NO.
BUILDING NAME
ADDRESS
CITY, STATE, ZIP
BUILDING NO.
PROJECT TITLE
GSA PROJECT NO.
SUBMISSION STAGE
SUBMISSION DATE
DRAWN BY
CHECKED BY
FLOOR NO.
DISCIPLINE
PLAN TYPE
SHEET NUMBER
AND FILENAME
KE
Y
PL
AN
GR
AP
HI
C
SC
AL
E
/1
/2
:2 :4
P
M
G101
18TH &29TH FLOOR
2010101
O. ORTEGA
J. STRYKER
230 S. DEARBORN ST.
N.A.
GENERAL
LIFE SAFETY
08/14/2017
ADDENDUM 1
EEOC
GS-05P-15-FA-D-XXXX
CHICAGO, IL 60604
IL0236FC
JOHN C. KLUCZYNSKI FEDERAL BUILDING
3/32" = 1'-0"
18TH FLOOR LIFE SAFETY PLAN
3/32" = 1'-0"
29TH FLOOR LIFE SAFETY PLAN
LEGEND:
EXISTING
DEMOLISHED
LEGEND:
EXISTING
KEY PLAN
N.T.S.
AREA OF WORK
RE
VI
SI
ON
B
LO
CK
CO
NT
RA
CT
DE
SI
GN
ER
ID
EN
TIF
IC
AT
IO
N
ST
AM
P
OR
S
EA
L
OW
NE
R
ID
EN
TIF
IC
AT
IO
N
BU
ILD
IN
G
PR
OJ
EC
T
SH
EE
T
P R
O P
E R
T Y
O F
T H
E U
N
IT
E D
S T
A T
E S
G O
V E
R N
M E
N T
F
O R
O F
F
IC
IA
L U
S E
O N
L Y
D
O N
O T
R E
M O
V E
T H
IS
N
O T
IC
E
P
R O
P E
R L Y
D E
S T
R O
Y D
O C
U M
E N
T S
W H
E N
N O
L O
N G
E R
N E
E D
E D
General Services Administration Public Buildings
Service Great Lakes Region 5
Professional Services Division John C. Kluczynski Federal Building 230 South Dearborn Street Chicago, IL 60604
CONST. CONTRACT NO.
DELIVER ORDER NO.
A/E CONTRACT NO.
BUILDING NAME
ADDRESS
CITY, STATE, ZIP
BUILDING NO.
PROJECT TITLE
GSA PROJECT NO.
SUBMISSION STAGE
SUBMISSION DATE
DRAWN BY
CHECKED BY
FLOOR NO.
DISCIPLINE
PLAN TYPE
SHEET NUMBER
AND FILENAME
KE
Y
PL
AN
GR
AP
HI
C
SC
AL
E
/1
/2
:4 :2
P
M
A101
18TH &29TH FLOOR
2010101
S. MORENO
J. STRYKER
230 S. DEARBORN ST.
ARCHITECTURE
N.A.
08/14/2017
ADDENDUM 1
EEOC
GS-05P-15-FA-D-XXXX
CHICAGO, IL 60604
IL0236FC
JOHN C. KLUCZYNSKI FEDERAL BUILDING
OVERALL ISOMETRIC - LEVEL 18 - NEW CONSTRUCTION
OVERALL ISOMETRIC - LEVEL 18 - DEMOLITION
MARK DATE DESCRIPTION
TYP.
LEGEND:
EXISTING
DEMOLISHED
LEGEND:
EXISTING
KEY PLAN
N.T.S.
AREA OF WORK
RE
VI
SI
ON
B
LO
CK
CO
NT
RA
CT
DE
SI
GN
ER
ID
EN
TIF
IC
AT
IO
N
ST
AM
P
OR
S
EA
L
OW
NE
R
ID
EN
TIF
IC
AT
IO
N
BU
ILD
IN
G
PR
OJ
EC
T
SH
EE
T
P R
O P
E R
T Y
O F
T H
E U
N
IT
E D
S T
A T
E S
G O
V E
R N
M E
N T
F
O R
O F
F
IC
IA
L U
S E
O N
L Y
D
O N
O T
R E
M O
V E
T H
IS
N
O T
IC
E
P
R O
P E
R L Y
D E
S T
R O
Y D
O C
U M
E N
T S
W H
E N
N O
L O
N G
E R
N E
E D
E D
General Services Administration Public Buildings
Service Great Lakes Region 5
Professional Services Division John C. Kluczynski Federal Building 230 South Dearborn Street Chicago, IL 60604
CONST. CONTRACT NO.
DELIVER ORDER NO.
A/E CONTRACT NO.
BUILDING NAME
ADDRESS
CITY, STATE, ZIP
BUILDING NO.
PROJECT TITLE
GSA PROJECT NO.
SUBMISSION STAGE
SUBMISSION DATE
DRAWN BY
CHECKED BY
FLOOR NO.
DISCIPLINE
PLAN TYPE
SHEET NUMBER
AND FILENAME
KE
Y
PL
AN
GR
AP
HI
C
SC
AL
E
/1
/2
:4 :4
P
M
A102
18TH &29TH FLOOR
2010101
S. MORENO
J. STRYKER
230 S. DEARBORN ST.
ARCHITECTURE
N.A.
08/14/2017
ADDENDUM 1
EEOC
GS-05P-15-FA-D-XXXX
CHICAGO, IL 60604
IL0236FC
JOHN C. KLUCZYNSKI FEDERAL BUILDING1
OVERALL ISOMETRIC - LEVEL 29 - DEMOLITION
OVERALL ISOMETRIC - LEVEL 29 - NEW CONSTRUCTION
SHEET KEYNOTES
1. EXISTING CONSTRUCTION AND FINISHES TO REMAIN WITHIN THE PREMISES AND IN ADJACENT
SPACES SHALL BE PROTECTED THROUGHOUT CONSTRUCTION. EXISTING ITEMS THAT ARE
INADVERTENTLY DAMAGED ARE TO BE REPAIRED TO PRE-DEMOLITOIN CONDITION.
2. EXISTING FIXTURES, FITTINGS DEVICES, ETC. TO BE REMOVED BACK TO POINT WHERE IT IS NO
LONGER EXPOSED. REFER TO MEPFP DRAWINGS FOR ADDITIONAL INFORMATION.
3. ALL DEMOLITION ACTIVITIES ARE TO COMPLY WITH LOCAL CODES PERTAINING TO DEMOLITION AND BUILDING REGULATIONS. DEMOLISHED MATERIAL IS TO BE DISPOSED OF IN AN ENVIRONMENTALLY
SAFE MANNER.
4. REMOVE ALL EXISTING FLOOR MTD. DOOR STOPS.
5. PROVIDE TEMPORARY SECURITY PARTITION IN A MANNER THAT WILL NOT IMPEDE MEANS OF
EGRESS ON THE FLOOR. MAINTAIN DURING CONSTRUCTION.
6. REMOVE EXISTING SIGNAGE MOUNTED ON EXISTING PARTITIONS AND TURN OVER TO THE GSA.
7. INSPECT FLOOR FOR RAISED OR DEPRESSED AREAS IN SLAB. FILL DEPRESSIONS AND
LEVEL RAISED AREAS TO PROVIDE LEVEL SURFACE APPROPRIATE FOR NE FLOOR COVERINGS.
8. PROVIDE FILTER MEDIA FOR RETURN GRILLES AND PROTECTION FOR FAN COILS DURING
DEMOLITION AND CONSTRUCTION.
9. SEE MECHANICAL, ELECTRICAL, PLUMBING, AND FIRE PROTECTION DRAWINGS FOR ADDITIONAL
DEMOLITION REQUIREMENTS.
10. EXISTING FIRE ALARM SYSTEM TO REMAIN ACTIVE THROUGHOUT CONSTRUCTION UNTIL NEW SYSTEM IS ACCEPTED BY CONTRACTING OFFICER. PROVIDE TEMPORARY SUPPORT AS REQUIRED.
SEE ELECTRICAL DRAWINGS.
11. PROVIDE TEMPORARY SUPPORT FOR HVAC AND FIRE ALARM SYSTEMS, INCLUDING REMOTE
INDICATOR LAMPS, TO REMAIN ACTIVE THROUGHOUT CONSTRUCTION. SEE MECHANICAL AND FIRE
PROTECTION DRAWINGS.
12. THE EXISTING SPRINKLER SYSTEM AND EQUIPMENT CAN BE TAKEN OUT OF SERVICE ONLY DURING
CONSTRUCTION PERIODS IN WHICH THE SPRINKLER SYSTEM IS BEING MODIFIED AND THE
CONTRACTOR IS AT THE WORK SITE. PRIOR TO LEAVING THE WORK SITE EACH DAY THE
CONTRACTOR SHALL RESTORE THE SPRINKLER SYSTEM TO SERVICE. IN ADDITION, ALL AREAS
OUTSIDE OF THIS PROJECT CONSTRUCTION AREA SHALL HAVE THEIR EXISTING FIRE PROTECTION
SPRINKLER SYSTEM IN FULL SERVICE PRIOR TO LEAVING THE WORK SITE EACH DAY.
DEMOLITION GENERAL NOTES
13. CONTRACTOR TO CONDUCT A COORDINATION MEETING, AFTER CEILING DEMOLITION IS
COMPLETED TO DETERMINE POTENTIAL CONFLICTS WITH EXISTING SPRINKLER PIPING AND
OTHER EXISTING UTILITIES WITH NEW LIGHT FIXTURE LOCATIONS. REPORT POTENTIAL CONFLICTS
TO COR FOR RESOLUTION. TYP.
14. ALL EXTERIOR WINDOWS HAVE TINTED SHADING FILM WHICH IS TO REMAIN. THIS FILM SHALL BE
PROTECTED DURING DEMOLITION AND CONSTRUCTION. FILM DAMAGED DURING THE WORK SHALL
BE REPLACED WITH IDENTICAL PRODUCT WITH RESPECT TO COLOR AND PERFORMANCE.
15. INSPECT ALL CONVECTOR COVERS FOR MISSING OR DAMAGED COMPONENTS. REPLACE EXISTING
DAMAGED CONVECTOR COVER OR MISSING/DAMAGED PORTION OF CONVECTOR COVER IN KIND.
USE EXISTING CONVECTOR COVER AS TEMPLATE AND MODEL TO REPLICATE CONVECTOR COVERS
IN DESIGN, PERFORMANCE, SHAPE AND DETAIL.
16. INSPECT FLOOR FOR RAISED OR DEPRESSED AREAS IN SLAB. FILL DEPRESSIONS AND LEVEL
RAISED AREAS TO PROVIDE LEVEL SURFACE APPROPRIATE FOR NEW FLOOR COVERINGS. (SEE
FINISH SCHEDULE SHT A910,A911) TYP.
17. EXISTING GYP. BD. COLUMN ENCLOSURES TO REMAIN. CUT & PATCH AS REQUIRED FOR
ELECTRICAL DEMOLITION. REFER TO ELECTRICAL DRAWINGS FOR ADDITIONAL INFORMATION.
18. PATCH FIREPROOFING, EXISTING & NEW. AFTER CEILING IS REMOVED, A WALKTHROUGH WITH THE
GSA WILL BE REQUIRED TO IDENTIFY EXISTING AREAS REQUIRING TO BE PATCHED.
19. REFERE TO DIVISION SPECIFICATION SECTIONS 012300 ALTERNATES AND 012400 OPTIONS
FOR SCOPE OF WORK THAT PERTAINS TO THIS PROJECT.
20. PATCH AND PROVIDE SMOOTH SURFACE TO ACCEPT NEW FINISH AS REQUIRED ON EXISTING
GYPSUM BOARD WALLS RECIEVING FIRE-RATED WOOD BLOCKING.
J H G F E D C B A
4/5
3/4
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OPEN
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
INTERVIEW
1814A
OPEN
OFFICE
WAITING
(ASSEMBLY
SPACE)
CLOSET
1827A
CLOSET
OFFICE
OFFICE
OFFICE
180047
TELECOM
OFFICE
OPEN
OFFICE
180046
OFFICE
(STORAGE)
ROOM
OFFICE
OFFICEOFFICE
CLOSET
TRAINING
1842OFFICE
OFFICE
FILE
OFFICE
CONFERENCE
OFFICE
COPY
OFFICE
OFFICE
OFFICE
OFFICE
180050
OFFICE
OFFICE
1812A
RECEPTION
180048
WAITING
(ASSEMBLY
SPACE)
1813A
TYP.
D1
TYP.
D1
D2 D3
D3
TYP.
D4
TYP.
D4
TYP.
D4
TELE
18MB
ELECT
18MA STAIR
18W
STORAGE
18MG
ELEVATOR
LOBBY
18MC
ELEVATOR
LOBBY
18CORB
WOMENS
TOILET
18TSW
MENS
TOILET
18TNW
STAIR
18E
TELE
18MD
ELECT
18ME
STRG
18MF
WOMENS
TOILET
18TNE
MENS
TOILET
18TSENIC CORR
18CORC
VEST
18MH
TYP.
D1
TYP.
D1
TYP.
D1
TYP.
D1
D2
D3
D3 D3
D3
TYP.
D4 TYP.
D4
D5
D5
D4
D6
D6
D5
D7
D8
D8
D9
D8
D9
D10
D10
D10
OPEN
OFFICE
D11
D13
D13
D15
D12
D14
D5 D5
TYP.
D16
TYP.
D16
D1
COPY
CORRIDOR
18CORA
CORRIDOR
18CORB
5' - 5"6' - 10" 3' - 7"
D17
D18
S M
O K
E B
A R
R
IE
R S
M O
K E
B A
R R
IE
R
D3
D17
D6
AD118
2 Sim
D2
(KEYNOTES APPLY TO THIS SHEET ONLY)
KEY PLAN
N.T.S.
AREA OF WORK
0 8' 16'
1/8"=1'-0"
RE
VI
SI
ON
B
LO
CK
CO
NT
RA
CT
DE
SI
GN
ER
ID
EN
TIF
IC
AT
IO
N
ST
AM
P
OR
S
EA
L
OW
NE
R
ID
EN
TIF
IC
AT
IO
N
BU
ILD
IN
G
PR
OJ
EC
T
SH
EE
T
P R
O P
E R
T Y
O F
T H
E U
N
IT
E D
S T
A T
E S
G O
V E
R N
M E
N T
F
O R
O F
F
IC
IA
L U
S E
O N
L Y
D
O N
O T
R E
M O
V E
T H
IS
N
O T
IC
E
P
R O
P E
R L Y
D E
S T
R O
Y D
O C
U M
E N
T S
W H
E N
N O
L O
N G
E R
N E
E D
E D
General Services Administration Public Buildings
Service Great Lakes Region 5
Professional Services Division John C. Kluczynski Federal Building 230 South Dearborn Street Chicago, IL 60604
CONST. CONTRACT NO.
DELIVER ORDER NO.
A/E CONTRACT NO.
BUILDING NAME
ADDRESS
CITY, STATE, ZIP
BUILDING NO.
PROJECT TITLE
GSA PROJECT NO.
SUBMISSION STAGE
SUBMISSION DATE
DRAWN BY
CHECKED BY
FLOOR NO.
DISCIPLINE
PLAN TYPE
SHEET NUMBER
AND FILENAME
KE
Y
PL
AN
GR
AP
HI
C
SC
AL
E
/1
/2
:4 :3
P
M
AD118
18TH &29TH FLOOR
2010101
O. ORTEGA
J. STRYKER
230 S. DEARBORN ST.
ARCHITECTURE
DEMOLITION PLAN
08/14/2017
ADDENDUM 1
EEOC
GS-05P-15-FA-D-XXXX
CHICAGO, IL 60604
IL0236FC
JOHN C. KLUCZYNSKI FEDERAL BUILDING
D12 REMOVE EXISTING FULL HEIGHT GLASS WALL, GLASS DOORS, AND ASSOCIATED HARDWARE INDICATED BY A DASHED
LINE.
D13 EXISTING BATHROOM, ENTRY WALL, AND DOOR AS WELL AS THE DRINKING FOUNTAIN RENOVATED TO THE BLDG
STANDARD ARE TO REMAIN. NO WORK TO BE DONE IN THIS ROOM.
D14 REMOVE EXISTING WRITING COUNTER MILLWORK INCLUDING COUNTERTOP, BUILT-UP WAINSCOT, 6"H BACKSPLASH AND
CABINET INDICATED BY A DAHSED LINE.
D15 REMOVE EXISTING DOUBLE DOOR WALL CABINET, WRITING COUNTER AND SHELF INDICATED BY A DAHSED LINE.
D16 EXISTING WALLS TO REMAIN ARE TO BE PATCHED AND SANDED TO PROVIDE SMOOTH SURFACE TO ACCEPT BUILDING STANDARD PAINT. WALLS WITH TEXTURED FINISH ARE TO BE SKIM-COATED AND SANDED SMOOTH TO ACCEPT NEW
FINISH.
D17 PROVIDE OPENING IN EXISTING TO REMAIN PARTITION TO ACCEPT SCHEDULED DOOR AND FRAME. REFER TO A118 FOR
ADDITIONAL INFORMATION.
D18 REMOVE EXISTING FIRE EXTINGUISHER AND ASSOCIATED RECESSED MOUNTED FIRE EXTINGUISHER CABINET
INDICATED BY A DAHSED LINE.
D1 REMOVE AND PROPERLY DISPOSE OF EXISTING WALLS INDICATED BY DASHED LINE, INCLUDING GLAZING, CHAIR RAILING, FABRIC WRAPPED PANELS, FRP PANELS AND CORNER GUARDS WITHIN EXISTING WALLS TO BE REMOVED.
WALL TYPES INCLUDE PLASTER AND DRYWALL FINISHED METAL STUD WALLS AND CMU.
D2 REMOVE ALL EXISTING INTERIOR DOORS, FRAMES, SIDELIGHTS AND ASSOCIATED HARDWARE INDICATED BY DASHED
LINE.
D3 REMOVE AND SALVAGE EXISTING KEYPAD ENTRY CONTROL AND ASSOCIATED COMPONENTS. TURN OVER TO GSA.
D4 REMOVE AND DISPOSE OF ALL EXISTING FLOOR COVERINGS AND ASSOCIATED ADHESIVES. FLOOR COVERINGS INCLUDE CARPET TILE, VCT AND RUBBER FLOORING. PREPARE LEVEL SURFACE APPROPRIATE FOR NEW FLOOR COVERINGS.
D5 REMOVE EXISTING WRITING COUNTER MILLWORK INCLUDING COUNTERTOP, VERTICAL SUPPRTS AND 24"H BACKSPLASH INDICATED BY A DAHSED LINE. PATCH EXISTING COLUMN ENCLOSURE SURFACE AS REQUIRED TO PROVIDE A SMOOTH
SURFACE TO ACCEPT NEW FINISH.
D6 PROVIDE TEMPORARY SECURITY PARTITION IN A MANNER THAT WILL NOT IMPEDE MEANS OF EGRESS ON THE 18TH
FLOOR. MAINTAIN THROUGHOUT CONSTRUCTION.
D7 REMOVE EXISTING OVERHEAD COILING COUNTER SHUTTER AND PLAM COUNTER INDICATED BY A DASHED LINE.
D8 REMOVE EXISTING SHELVING WITH BRACKETS AND SURFACE MOUNTED STANDARDS INDICATED BY A DASHED LINE.
D9 REMOVE EXISTING SHELVING AND ASSOCIATED CLEATS WITH COAT ROD INDICATED BY A DASHED LINE.
D10 REMOVE EXISTING ADJUCIATION COUNTERS INDICATED BY A DASHED LINE. THEY ARE COMPRISED OF BR GLAZING, BR DEAL TRAYS, BUILT-UP SUPPORT WALLS W/ BR ARMOR SHEETS. EACH STATION HAS PLAM COUNTERS ON BOTH SIDES, MAIL SLOTS, DRAWERS AND A FOOT REST AT THE EMPLOYEE SIDE. WALLS AND HALF-HEIGHT WALLS BETWEEN EACH
COUNTER ARE CLAD W/ PLAM.
D11 REMOVE EXISTING UNEVEN DOUBLE DOORS, FRAME AND ASSOCIATED HARDWARE INDICATED BY A DASHED LINE TO BE
REINSTALLED AT COLUMN F\3. REFER TO SHEET A118 FOR ADDITIONAL INFORMATION.
1/8" = 1'-0"1
18TH FLOOR DEMOLITION PLAN
N.T.S.2
EXISTING MILLWORK AT 1815
DN
1. EXISTING CONSTRUCTION AND FINISHES TO REMAIN WITHIN THE PREMISES AND IN ADJACENT
SPACES SHALL BE PROTECTED THROUGHOUT CONSTRUCTION. EXISTING ITEMS THAT ARE
INADVERTENTLY DAMAGED ARE TO BE REPAIRED TO PRE-DEMOLITOIN CONDITION.
2. EXISTING FIXTURES, FITTINGS DEVICES, ETC. TO BE REMOVED BACK TO POINT WHERE IT IS NO
LONGER EXPOSED. REFER TO MEPFP DRAWINGS FOR ADDITIONAL INFORMATION.
3. ALL DEMOLITION ACTIVITIES ARE TO COMPLY WITH LOCAL CODES PERTAINING TO DEMOLITION AND BUILDING REGULATIONS. DEMOLISHED MATERIAL IS TO BE DISPOSED OF IN AN ENVIRONMENTALLY
SAFE MANNER.
4. REMOVE ALL EXISTING FLOOR MTD. DOOR STOPS.
5. PROVIDE TEMPORARY SECURITY PARTITION IN A MANNER THAT WILL NOT IMPEDE MEANS OF
EGRESS ON THE FLOOR. MAINTAIN DURING CONSTRUCTION.
6. REMOVE EXISTING SIGNAGE MOUNTED ON EXISTING PARTITIONS AND TURN OVER TO THE GSA.
7. INSPECT FLOOR FOR RAISED OR DEPRESSED AREAS IN SLAB. FILL DEPRESSIONS AND
LEVEL RAISED AREAS TO PROVIDE LEVEL SURFACE APPROPRIATE FOR NE FLOOR COVERINGS.
8. PROVIDE FILTER MEDIA FOR RETURN GRILLES AND PROTECTION FOR FAN COILS DURING
DEMOLITION AND CONSTRUCTION.
9. SEE MECHANICAL, ELECTRICAL, PLUMBING, AND FIRE PROTECTION DRAWINGS FOR ADDITIONAL
DEMOLITION REQUIREMENTS.
10. EXISTING FIRE ALARM SYSTEM TO REMAIN ACTIVE THROUGHOUT CONSTRUCTION UNTIL NEW SYSTEM IS ACCEPTED BY CONTRACTING OFFICER. PROVIDE TEMPORARY SUPPORT AS REQUIRED.
SEE ELECTRICAL DRAWINGS.
11. PROVIDE TEMPORARY SUPPORT FOR HVAC AND FIRE ALARM SYSTEMS, INCLUDING REMOTE
INDICATOR LAMPS, TO REMAIN ACTIVE THROUGHOUT CONSTRUCTION. SEE MECHANICAL AND FIRE
PROTECTION DRAWINGS.
12. THE EXISTING SPRINKLER SYSTEM AND EQUIPMENT CAN BE TAKEN OUT OF SERVICE ONLY DURING
CONSTRUCTION PERIODS IN WHICH THE SPRINKLER SYSTEM IS BEING MODIFIED AND THE
CONTRACTOR IS AT THE WORK SITE. PRIOR TO LEAVING THE WORK SITE EACH DAY THE
CONTRACTOR SHALL RESTORE THE SPRINKLER SYSTEM TO SERVICE. IN ADDITION, ALL AREAS
OUTSIDE OF THIS PROJECT CONSTRUCTION AREA SHALL HAVE THEIR EXISTING FIRE PROTECTION
SPRINKLER SYSTEM IN FULL SERVICE PRIOR TO LEAVING THE WORK SITE EACH DAY.
DEMOLITION GENERAL NOTES
13. CONTRACTOR TO CONDUCT A COORDINATION MEETING, AFTER CEILING DEMOLITION IS
COMPLETED TO DETERMINE POTENTIAL CONFLICTS WITH EXISTING SPRINKLER PIPING AND
OTHER EXISTING UTILITIES WITH NEW LIGHT FIXTURE LOCATIONS. REPORT POTENTIAL CONFLICTS
TO COR FOR RESOLUTION. TYP.
14. ALL EXTERIOR WINDOWS HAVE TINTED SHADING FILM WHICH IS TO REMAIN. THIS FILM SHALL BE
PROTECTED DURING DEMOLITION AND CONSTRUCTION. FILM DAMAGED DURING THE WORK SHALL
BE REPLACED WITH IDENTICAL PRODUCT WITH RESPECT TO COLOR AND PERFORMANCE.
15. INSPECT ALL CONVECTOR COVERS FOR MISSING OR DAMAGED COMPONENTS. REPLACE EXISTING
DAMAGED CONVECTOR COVER OR MISSING/DAMAGED PORTION OF CONVECTOR COVER IN KIND.
USE EXISTING CONVECTOR COVER AS TEMPLATE AND MODEL TO REPLICATE CONVECTOR COVERS
IN DESIGN, PERFORMANCE, SHAPE AND DETAIL.
16. INSPECT FLOOR FOR RAISED OR DEPRESSED AREAS IN SLAB. FILL DEPRESSIONS AND LEVEL
RAISED AREAS TO PROVIDE LEVEL SURFACE APPROPRIATE FOR NEW FLOOR COVERINGS. (SEE
FINISH SCHEDULE SHT A910,A911) TYP.
17. EXISTING GYP. BD. COLUMN ENCLOSURES TO REMAIN. CUT & PATCH AS REQUIRED FOR
ELECTRICAL DEMOLITION. REFER TO ELECTRICAL DRAWINGS FOR ADDITIONAL INFORMATION.
18. PATCH FIREPROOFING, EXISTING & NEW. AFTER CEILING IS REMOVED, A WALKTHROUGH WITH THE
GSA WILL BE REQUIRED TO IDENTIFY EXISTING AREAS REQUIRING TO BE PATCHED.
19. REFERE TO DIVISION SPECIFICATION SECTIONS 012300 ALTERNATES AND 012400 OPTIONS
FOR SCOPE OF WORK THAT PERTAINS TO THIS PROJECT.
20. PATCH AND PROVIDE SMOOTH SURFACE TO ACCEPT NEW FINISH AS REQUIRED ON EXISTING
GYPSUM BOARD WALLS RECIEVING FIRE-RATED WOOD BLOCKING.
(KEYNOTES APPLY TO THIS SHEET ONLY)
J H G F E D C B A
4/5
3/4
ELEVATOR
LOBBY
WOMENS
TOILET
MENS
TOILET
STAIR
TELE
ELECT
TELE
WOMENS
TOILET
MENS
TOILET
ELEVATOR
LOBBY
NIC
OFFICE
OFFICE
OFFICE
OPEN
OFFICE
OFFICE
OFFICE
OFFICE
2916A
OFFICE
2914A
OFFICE
(ASSEMBLY)
OFFICE
OFFICE
TELECOM
BREAK
VEST.
CLASSROOMS
STORAGE
STORAGE
CREDIT
UNION
CREDIT
UNION
CREDIT
UNION
CREDIT
UNION
TYP.
D1
TYP.
D1
D3
D3
TYP.
D4
TYP.
D4
TYP.
D4
D5
D6
D6
D7
D7
D8
D8
D8D8
D8
D8
D8
D1
TYP.
D9
TYP.
D9
D9D3
D3
TYP.
D1
D2
TYP.
D1
D3
D3
D6
1' - 6"
D2
5' - 1"
4"
D10
KEY PLAN
N.T.S.
AREA OF WORK
0 8' 16'
1/8"=1'-0"
RE
VI
SI
ON
B
LO
CK
CO
NT
RA
CT
DE
SI
GN
ER
ID
EN
TIF
IC
AT
IO
N
ST
AM
P
OR
S
EA
L
OW
NE
R
ID
EN
TIF
IC
AT
IO
N
BU
ILD
IN
G
PR
OJ
EC
T
SH
EE
T
P R
O P
E R
T Y
O F
T H
E U
N
IT
E D
S T
A T
E S
G O
V E
R N
M E
N T
F
O R
O F
F
IC
IA
L U
S E
O N
L Y
D
O N
O T
R E
M O
V E
T H
IS
N
O T
IC
E
P
R O
P E
R L Y
D E
S T
R O
Y D
O C
U M
E N
T S
W H
E N
N O
L O
N G
E R
N E
E D
E D
General Services Administration Public Buildings
Service Great Lakes Region 5
Professional Services Division John C. Kluczynski Federal Building 230 South Dearborn Street Chicago, IL 60604
CONST. CONTRACT NO.
DELIVER ORDER NO.
A/E CONTRACT NO.
BUILDING NAME
ADDRESS
CITY, STATE, ZIP
BUILDING NO.
PROJECT TITLE
GSA PROJECT NO.
SUBMISSION STAGE
SUBMISSION DATE
DRAWN BY
CHECKED BY
FLOOR NO.
DISCIPLINE
PLAN TYPE
SHEET NUMBER
AND FILENAME
KE
Y
PL
AN
GR
AP
HI
C
SC
AL
E
/1
/2
:4 :3
P
M
AD119
18TH &29TH FLOOR
2010101
O. ORTEGA
J. STRYKER
230 S. DEARBORN ST.
ARCHITECTURE
DEMOLITION PLAN
08/14/2017
ADDENDUM 1
EEOC
GS-05P-15-FA-D-XXXX
CHICAGO, IL 60604
IL0236FC
JOHN C. KLUCZYNSKI FEDERAL BUILDING
D1 REMOVE AND PROPERLY DISPOSE OF EXISTING WALLS INDICATED BY DASHED LINE, INCLUDING GLAZING, CHAIR RAILING, FABRIC WRAPPED PANELS, FRP PANELS AND CORNER GUARDS WITHIN EXISTING WALLS TO BE REMOVED.
WALL TYPES INCLUDE PLASTER AND DRYWALL FINISHED METAL STUD WALLS AND CMU.
D2 REMOVE ALL EXISTING INTERIOR DOORS, FRAMES AND ASSOCIATED HARDWARE INDICATED BY DASHED LINE.
D3 REMOVE AND SALVAGE EXISTING CONTROLLED ACCESS HARDWARE AND ASSOCIATED COMPONENTS. TURN OVER TO
GSA.
D4 REMOVE AND DISPOSE OF ALL EXISTING FLOOR COVERINGS AND ASSOCIATED ADHESIVES. FLOOR COVERINGS INCLUDE CARPET TILE, VCT AND RUBBER FLOORING. PREPARE LEVEL SURFACE APPROPRIATE FOR NEW FLOOR COVERINGS.
D5 EXISTING MILLWORK, COUNTERTOPS, WORKSURFACES, BASE AND WALL CABINETS ARE TO BE REMOVED. REMOVE EXISTING SINK AND GARBAGE DISPOSAL. REFER TO PLUMBING ELECTRICAL DWGS FOR ADDITIONAL INFORMATION.
D6 PROVIDE TEMPORARY SECURITY PARTITION IN A MANNER THAT WILL NOT IMPEDE MEANS OF EGRESS ON THE 18TH FLOOR. MAINTAIN THROUGHOUT CONSTRUCTION. IMPEDE EGRESS ON THE 29TH FLOOR AS WELL AS ACCESS TO THE
CORE BATHROOMS AT THE EAST END OF THE PUBLIC CORRIDORS.
D7 REMOVE EXISTING COOLING EQUIPMENT AND ASSOCIATED PIPING.
D8 ORIGINAL BUILDING STANDARD DEMOUNTABLE PARTITIONS INDICATED BY DASHED LINE ARE TO BE REMOVED FOR
TURNOVER TO GSA. STORE IN BUILDING AS DIRECTED BY GSA.
D9 ORIGINAL BUILDING STANDARD DEMOUNTABLE PARTITIONS DOORS, FRAMES, SIDELITES AND ASSOCIATED HARDWARE IN TENANT SUITE INDICATED BY DASHED LINE ARE TO BE REMOVED FOR TURNOVER TO GSA. STORE IN BUILDING AS
DIRECTED BY GSA.
D10 PROVIDE OPENING IN EXISTING TO REMAIN PARTITION TO ACCEPT SCHEDULED DOOR AND FRAME. REFER TO A119 FOR
ADDITIONAL INFORMATION.
1/8" = 1'-0"1
29TH FLOOR DEMOLITION PLAN
c
C
C
C
C
C
C
C
C C
C C
C
C
C
C
C
C
SV SV SV
OS OSSV SV
SV
SV
SV
SV
SV
SV
SV
SV
SV
SV
SV
SVSV OSSVOS
SV
OS
OS
SV
SV
SV
SV
SV
SV
SV
SV
OS
S
S S
S
S
S S
S
S
S
S
S
S
S
S
SS
S
S
S
S
S
S
S
S
S
S
S
DEMOLITION GENERAL NOTES
1. EXISTING CONSTRUCTION AND FINISHES TO REMAIN WITHIN THE PREMISES AND IN ADJACENT SPACES SHALL BE
PROTECTED THROUGHOUT CONSTRUCTION. EXISTING ITEMS THAT ARE INADVERTENTLY DAMAGED ARE TO BE REPAIRED
TO PRE-DEMOLITOIN CONDITION.
2. EXISTING FIXTURES, FITTINGS DEVICES, ETC. TO BE REMOVED BACK TO POINT WHERE IT IS NO LONGER EXPOSED. REFER
TO MEPFP DRAWINGS FOR ADDITIONAL INFORMATION.
3. ALL DEMOLITION ACTIVITIES ARE TO COMPLY WITH LOCAL CODES PERTAINING TO DEMOLITION AND BUILDING REGULATIONS.
DEMOLISHED MATERIAL IS TO BE DISPOSED OF IN AN ENVIRONMENTALLY SAFE MANNER.
4. REMOVE EXISTING SUSPENDED ACOUSTICAL CEILING GRID AND TILE AS REQ'D FOR MECHANICAL IMPROVEMENT.
5. REMOVE AND SALVAGE ALL ACOUSTIC PRIVACY INSULATION OVER EXISTING DEMOUNTABLE PARTITIONS TO BE REMOVED
FOR REUSE IN THE NEW TENANT SPACE.
6. LIGHT FIXTURES, MECHANICAL DIFFUSERS, SPRINKLER HEADS, AND OTHER MECHANICAL, ELECTRICAL, AND
TELECOMMUNICATION ITEMS ARE SHOWN FOR OVERALL COORDINATION. SEE MECHANICAL, ELECTRICAL, FIRE PROTECTION AND TELECOMMUNICATION DRAWINGS FOR ADDITIONAL INFORMATION.
REFLECTED CEILING PLAN LEGEND
EXISTING BUILDING STANDARD SUSPENDED
ACOUSTICAL CEILING TILE, GRID AND LAYOUT TO
REMAIN.
EXISTING BUILDING STANDARD 8"x48" RECESSED
MOUNTED LIGHT FIXTURE TO REMAIN.
EXISTING BUILDING STANDARD 6" DIAMETER
RECESSED MOUNTED DOWNLIGHT TO REMAIN.
EXISTING SPRINKLER HEAD TO REMAIN.
EXISTING SUPPLY AND RETURN AIR DIFFUSER TO REMAIN.
REFER TO MECHANICAL DRAWINGS FOR LOCATION.
DEMOLISHED 6" DIAMETER RECESSED MOUNTED
DOWNLIGHT.
DEMOLISHED 8"x48" RECESSED MOUNTED LIGHT FIXTURE
DEMOLISHED SPRINKLER HEAD
EXISTING SUPPLY AND RETURN AIR DIFFUSER TO BE REMOVED.
REFER TO MECHANICAL DRAWINGS FOR LOCATION.
CEILING MOUNTED EXIT SIGN
FIRE ALARM DEVICES / SENSORS
S
FIRE ALARM DEVICE CEILING MOUNTED
OS OCCUPANCY SENSOR
DS DAYLIGHT SENSOR
VS VACANCY SENSOR
SUSPENDED GYPSUM BOARD CEILING
EXISTING SUSPENDED GYPSUM BOARD
SMOKE WALL TO REMAIN
DEMOLISHED SUSPENDED
ACOUSTICAL CEILING TILE, GRID.
MC CEILING MICROPHONE
FIRE ALARM DEVICE W/ VISUAL ARMSV
C SECURITY DEVICE CAMERA
J H G F E D C B A
4/5
3/4
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OPEN
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
INTERVIEW
1814A
OPEN
OFFICE
WAITING
(ASSEMBLY
SPACE)
CLOSET
1827A
CLOSET
OFFICE
OFFICE
OFFICE
180047
TELECOM
OFFICE
OPEN
OFFICE
180046
OFFICE
(STORAGE)
ROOM
OFFICE
OFFICE
OFFICE
CLOSET
TRAINING
1842OFFICE
OFFICE
FILE
OFFICE
CONFERENCE
OFFICE
COPY
OFFICE
OFFICE
OFFICE
OFFICE
180050
OFFICE
OFFICE
1812A
RECEPTION
180048
WAITING
(ASSEMBLY
SPACE)
1813A
TELE
18MB
ELECT
18MA STAIR
18W
STORAGE
18MG
ELEVATOR
LOBBY
18MC
ELEVATOR
LOBBY
18CORB
WOMENS
TOILET
18TSW
MENS
TOILET
18TNW
STAIR
18E
TELE
18MD
ELECT
18ME
STRG
18MF
WOMENS
TOILET
18TNE
MENS
TOILET
18TSE
NIC CORR
18CORC
VEST
18MH
TYP.
D1
D2
TYP.
D3
TYP.
D4
TYP.
D5
TYP.
D6
A120
TYP.
D1
TYP.
D1
TYP.
D1
D2
TYP.
D3
D2
TYP.
D3
D2
TYP.
D3
TYP.
D4
TYP.
D4
TYP.
D4
TYP.
D6
TYP.
D6
TYP.
D6
TYP.
D6
TYP.
D6
TYP.
D5
TYP.
D7
TYP.
D5
D9
D9
D8
D7
D8 D8 D8
D8
TYP.
D5
TYP.
D7
COPY
A913
D8
KEY PLAN
N.T.S.
AREA OF WORK
0 8' 16'
1/8"=1'-0"
RE
VI
SI
ON
B
LO
CK
CO
NT
RA
CT
DE
SI
GN
ER
ID
EN
TIF
IC
AT
IO
N
ST
AM
P
OR
S
EA
L
OW
NE
R
ID
EN
TIF
IC
AT
IO
N
BU
ILD
IN
G
PR
OJ
EC
T
SH
EE
T
P R
O P
E R
T Y
O F
T H
E U
N
IT
E D
S T
A T
E S
G O
V E
R N
M E
N T
F
O R
O F
F
IC
IA
L U
S E
O N
L Y
D
O N
O T
R E
M O
V E
T H
IS
N
O T
IC
E
P
R O
P E
R L Y
D E
S T
R O
Y D
O C
U M
E N
T S
W H
E N
N O
L O
N G
E R
N E
E D
E D
General Services Administration Public Buildings
Service Great Lakes Region 5
Professional Services Division John C. Kluczynski Federal Building 230 South Dearborn Street Chicago, IL 60604
CONST. CONTRACT NO.
DELIVER ORDER NO.
A/E CONTRACT NO.
BUILDING NAME
ADDRESS
CITY, STATE, ZIP
BUILDING NO.
PROJECT TITLE
GSA PROJECT NO.
SUBMISSION STAGE
SUBMISSION DATE
DRAWN BY
CHECKED BY
FLOOR NO.
DISCIPLINE
PLAN TYPE
SHEET NUMBER
AND FILENAME
KE
Y
PL
AN
GR
AP
HI
C
SC
AL
E
/1
/2
:4 :3
P
M
AD318
18TH &29TH FLOOR
2010101
O. ORTEGA
J. STRYKER
230 S. DEARBORN ST.
ARCHITECTURE
DEMOLITION RCP
08/14/2017
ADDENDUM 1
EEOC
GS-05P-15-FA-D-XXXX
CHICAGO, IL 60604
IL0236FC
JOHN C. KLUCZYNSKI FEDERAL BUILDING
D1 EXISTING SUSPENDED ACOUSTICAL CEILING…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .