GSA DB Preproposal Conf 20100812.ppt
PPT presentation 3 MB Posted
- Attached to
- Bridging Design Build (BDB) Construction Services New Federal Office Building - Broward County, Florida Federal contract opportunity
- Solicitation number
- GS-04P-10-BV-C-0065
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| GS-04P-10-BV-C-0065 Small Business Netowrking Session Rev 1.docx | DOCX document | |
| GS-04P-10-BV-C-0065 Small Business Netowrking Session.docx | DOCX document | |
| GS-04P-10-BV-C-0065 ShortList Announcement.docx | DOCX document | |
| GS-04P-10-BV C-0065 Amendment 2.pdf | ||
| GS-04P-10-BV C-0065 Amendment 1.pdf | ||
| GS-04P-10-BV C-0065 Questions Rev 3.docx | DOCX document | |
| GS-04P-10-BV-C-0065 Preproposal Conference Questions.docx | DOCX document | |
| Preproposal Conference Attendee List.pdf | ||
| GS-04P-10-BV C-0065 Questions Rev 2.docx | DOCX document | |
| GS-04P-10-BV C-0065 Questions.docx | DOCX document | |
| RFQ Phase I.pdf | ||
| Questionnaire.docx | DOCX document |
Show all 12
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Pre-Proposal Conference U. S. Federal Office Building, Miramar Florida Solicitation Number-GS-04P-10-BV-C-0065
GSA Southeast Sunbelt Region
U.S. General Services Administration
Introduction - Agenda
| Pre-Proposal Conference |
| Project Organization |
| Acquisition Process |
| Contracting with GSA |
| Project Overview |
| Security Requirements |
| Amendment(s) to RFP |
| Questions |
Project Organization GSA Contractors Principal Ron Krueck Mark Sexton Project Manager Tim Tracey Consultants Engineers Tenant Project Manager Tenant Tenant Architect GSA – Director Design and Construction Richard Stephenson Delegated Authority
PES/CM
Jacobs Engineering Project Manager Jon Jordan Design Management Tom Massey Commissioning Craig Johnson QC Superintendant Richard Fisher Coordination Coordination Lead Designer Krueck and Sexton Coordination Principal-In Charge Project Manager Construction Superintendant MEP Coordinator A/E Project Manager Design Architect Quality Control Superintendant Government Team Design/Builder TBD
GSA - COR
Project Manager Steven C. Smith GSA – Contracting Officer Lawrence Hales GSA – Deputy Commissioner James Weller Tenant Assistant Director
Acquisition Process
| Request for Qualifications (RFQ) | ||||
| RFQ Responses Due | September 10, 2010 | |||
| Government Establishes Short List (5 Firms) | September 24, 2010 | |||
| Request for Proposals (RFP) | ||||
| Government Issues RFP | October 14, 2010 | |||
| Proposals Due | November 29, 2010 | |||
| Government Establishes Competitive Range | December 3, 2010 | |||
| Conduct Interviews | December 6-7, 2010 | |||
| Contract Award | December 17, 2010 | |||
| Post Award | ||||
| Design NTP | December 20, 2010 | |||
| Construction NTP | April 2011 | |||
| Construction Substantial Completion | September 30, 2013 | |||
| Contract Final Completion | January 2014 | |||
| Period of Performance 1015 Calendar Days |
Contracting with the GSA CCR registration www.ccr.gov FedBizOpps www.fbo.gov Small Business Administration
Project Overview
| 475,000 gross square foot building |
| 535 structured, |
| 500 surface parking spaces. |
| 100 foot property line setback |
| Enhanced security specifications |
| P-100 (Facility Standards for Public Buildings) |
| Leadership in Energy and Environmental Design (LEED) |
| LEED GOLD certification, and customer agency |
| Special purpose space. |
| Laboratory |
| Private restrooms |
| Food service |
| Automated Data Processing Center |
| Conference/training, |
| Physical fitness |
| Vehicle bay/maintenance, |
| Boat bay, |
| Emergency generator, |
| Weapons/ammo vaults, |
| Processing rooms, |
| Inside parking/garage space. |
Project Overview - Schematic Model
| Office Building |
| Annex |
| Parking Structure |
| Surface Parking |
| Primary and Secondary Entries |
| Visitor Parking/Screening |
| Retention Pond |
Project Overview - Location Plan
| Pembroke Road |
| SW 145 Ave |
| I-75 |
Project Overview - Area Plan
Project Overview - Site Plan Subdivided 40 Acre Parcel
20 Acre Project Site
10 Acre Wetland
Two Points of Entry
Canal
Project Overview - Site Plan View
Security Requirements
| Document Security: |
| The contractor shall protect all information pertaining to the project in accordance with GSA guidelines PBS Order 3490.1 Document security for sensitive but unclassified paper and electronic building information |
| Personnel Security: |
| HSPD 12 - Electronic Project Management system |
| Additional Clearances: Required for Document Security and Construction Site access. |
| Security Design Requirements: |
| The facility will be designed to include physical security countermeasures. Design Basis Tactics have been considered in the development of the design requirements. |
| Construction Site Security Requirements and Procedures will be identified during the RFP Phase |
Amendment(s) to RFQ
| Clarification issued August 5, 2010 |
| Clarification issued August 13, 2010 |
| Clarification August 15, 2010 (E) |
For Additional Information contact:
Lawrence Hales, Contracting Officer
Phone: (404) 224-2314
FAX: (404) 331-7696
lawrence.hales@gsa.gov
END
File details come from the government source that posted it. Updated .