GS-01P-15-BZ-C-0004 _Amendment_0004_26_March_2015_.pdf
PDF 81 KB Posted
- Attached to
- Renovate IFR to Training and Fitness Room, U. S. Border Patrol Houlton Sector Headquarters, Hodgdon, Maine
- Solicitation number
- GS-01P-15-BZ-C-0004
About this file
Amendment 0004 -Bid due date and time extended to 2 00 PM April 3 2015.
View the file
Other files
Show all 16
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT
1. CONTRACT ID CODE
GS-01P-15-BZ-C-0004
PAGES
1 7 2. AMENDMENT/MODIFICATION NO.
3. EFFECTIVE DATE
3/26/2015
4. REQUISITION/PURCHASE REQ. NO.
1PSK-15-0028
5. PROJECT NO. (If applicable)
6. ISSUED BY CODE 7. ADMINISTERED BY (If other than Item 6) CODE
ACQUISITION BRANCH, SVC CENTERS DIV
GSA/PBS
10 Causeway St. RM 1100
BOSTON MA 02222-1077
ACQUISITION BRANCH, SVC CENTERS DIV
GSA/PBS
10 Causeway St. RM 1100
BOSTON MA 02222-1077
8. NAME AND ADDRESS OF CONTRACTOR (NO., STREET, COUNTY, STATE AND ZIP CODE)
9A. AMENDMENT OF SOLICITATION NO.
GS-01P-15-BZ-C-0004
9B. DATED (SEE ITEM 11)
2/27/2015
10A. MODIFICATION OF CONTRACT/ORDER NO.
10B. DATED (SEE ITEM 13)
CODE FACILITY CODE
11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS
The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offers is extended, is not extended.
Offers must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended, by one of the following methods:
(a) By completing Items 8 and 15, and returning 1 copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted or (c) By separate letter or telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGEMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such Change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.
12. ACCOUNTING AND APPROPRIATION DATA (If required)
13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS,
IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.
A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE CONTRACT ORDER NO. IN
ITEM 10A.
B. THE ABOVE REFERENCED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation date, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(b).
C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:
D. OTHER (SPECIFY TYPE OF MODIFICATION AND AUTHORITY)
E. IMPORTANT: Contractor is not, is required to sign this document and return _ copies to the issuing office.
14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)
Solicitation, GS-01P-15-BZ-C-0004 ,Indoor Firing Range Renovation , USBPSH, Hodgdon, ME, is hereby amended to answer questions.
The bid due date and time has been EXTENDED TO: 2:00PM, April 3, 2015.
THIS AMENDMENT MUST BE ACKNOWLEDGED BY ONE OF THE METHODS IN BLOCK 11.
Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.
15A. NAME AND TITLE OF SIGNER (Type or Print)
16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)
15B. CONTRACTOR/OFFEROR
(Signature of person authorized to sign)
15C. DATE SIGNED
16B UNITED STATES OF AMERICA
BY
(Signature of Contracting Officer)
16C. DATE SIGNED
NSN 7540-01-152-8070 STANDARD FORM 30 (Rev. 10-83) PREVIOUS EDITION UNUSABLE Prescribed by GSA
FAR (48 CFR) 53.243
Amendment 0002/GS-01P-15-BZ-C-0004 Page 2
Questions and Answers as of March 26, 2015:
Q64: During the site walk it was mentioned the contractor is required to protect their work and tenants per section
020900 which also refers to OSHA 29 CFR 1926.62. This spec is referring to abatement professionals. Is it the intent to abate this project during the construction phase?
A: See answer to Question 66.
Q65: To get a baseline reading of lead dust there must be some preliminary testing prior to construction. If the test reveals elevated levels of lead exceeding the PEL, are there funds to cover the abatement?
A: See answer to Question 66.
Q66: Can you please clarify the scope of work required for the removal and testing for lead?"
A66.The level for office space (from HUD) is 40 ug/sf based on wipe sampling. The Contractor shall isolate the entire area, clean all cleanable surfaces, dismantle and dispose of all Indoor Firing Range components; ducts, trap, ballistic protection, targeting systems, control room, and other contaminated materials. Clean all remaining surfaces in the space to 40 ug/sf lead.
Remove all ductwork associated with the indoor firing range. All Concrete Floors in the existing range area shall be coated to encapsulate the lead dust or otherwise covered with floor covering.
During construction, the space shall be kept under negative pressure to avoid dust getting out the door(s) when opened.
The Government reserves the right to perform additional testing.
The contractor shall provide a workplan, including a schedule, to the Government.
All Concrete Floors in the existing range area shall be coated to encapsulate the lead dust if it cannot be cleaned to
40 ug/sf. This includes encapsulating floors before being covered with carpet or tile.
Q67: On drawing A101 please confirm the government is requesting a Level 5 (100% skim coat coverage) for all wall surfaces designated PT-01 and not a Level 4 (Tape and Joint Compound on all seams) as typically found in commercial applications.
A67: Government is requesting a Level 5 (100% skim coat coverage) for all wall surfaces designated PT-01.
Q68. This is a request for the Level III Performance Specification referenced in Amendment 002 question 17 and answer A17
A17 - An ATFP window is not required. The new windows will need to meet Border Patrol’s Level III performance specifications, an interior ¼’ panel of laminated glass as part of the 1’’ insulated glass system with a minimum 7 mil film to provide the proper blast resistance and force protection for Level III facilities.
Could we get a copy of the Level III performance specifications and or clarify that what is listed in Amendment 2 along with the window spec 085113 & glazing spec 088000 meet all the requirements?
A68. Use the combination of the Aluminum Window specification Section 085113 and the insulated glass specified in Section 088000 Glazing and the requirements of Level III will be met.