GPO Facility Management Suite Renovation Final Submission DRAWINGS 2025-05-02.pdf
PDF 46 MB Posted
- Solicitation number
- 040ADV-26-R-0013
- Issued by
-
Government Publishing Office
About this file
This file is a set of architectural and engineering drawings for the Government Publishing Office (GPO) Facility Management Modernization project located at 732 North Capitol Street NW, Washington, DC 20401. The drawings document a comprehensive renovation of approximately 15,300 square feet on the second floor of Building A, classified as a Level 2 alteration involving facility management, HVAC, office, and restroom modernization.
The project scope encompasses architectural modifications including demolition and new partition construction with sound attenuation, interior finishes (gypsum board ceilings at 9'-6" AFF, luxury vinyl tile and carpet tile flooring, porcelain tile in toilet areas, paint finishes in specified colors), millwork and built-in cabinetry, ADA-compliant door and window modifications, and signage. Mechanical systems include three new air handling units (AHU-1, AHU-2, AHU-3 ranging from 3,690 to 6,845 CFM), variable air volume (VAV) boxes for zone control, heating and cooling coil modifications with steam and chilled water piping, and ductwork distribution. Plumbing work involves installation of new water closets, lavatories, service sinks, and drinking fountains with associated supply and waste piping. Electrical systems include new panelboards (RP-1, RP-2, RP-1A at 208/120V, 400A MCB ratings), lighting with occupancy sensors and dimming controls, receptacle circuits with controlled loads, and data/telecommunications infrastructure. Fire protection systems include modifications to the existing wet pipe sprinkler system, fire alarm devices (smoke detectors, manual pull stations, audio/visual appliances), and duct smoke detectors for HVAC units. The drawings are dated April 2, 2025 (Final Submission) and prepared by EBL Engineers, LLC and Gannett Fleming Transystems, with professional engineering certification required for Maryland licensure.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
G-001
DRAWING LIST
DRAWING #: SHEET DESCRIPTION:
410-668-8000 FAX 410-668-8001
BALTIMORE, MARYLAND 21234-5701
8005 HARFORD ROAD
EBL ENGINEERS, LLC
COVER SHEET
LOCATION MAP NVICINITY MAP
NO SCALE
N
NO SCALE
FINAL SUBMISSION
APRIL 2, 2025
FM HVAC/OFFICE/RESTROOM MODERNIZATION
US GOVERNMENT PUBLISHING OFFICE
PROJECT LOCATION
PROJECT LOCATION
410-512-4500
BALTIMORE, MARYLAND 21286
300 E. JOPPA ROAD SUITE 200
GANNETT FLEMING TRANSYSTEMS
A-001 A-002 A-003
AD-101
AD-102
AD-201
AD-202
A-100 A-101 A-102 A-201 A-202 A-300 A-310 A-311 A-312 A-401 A-402 A-403 A-500 A-501 A-502 A-503 A-504 A-601 A-602
GENERAL NOTES AND CONDITIONS, ABBREVIATIONS AND SYMBOLS
TYPICAL ADA CLEARANCES AND MOUNTING HEIGHTS
CODE ANALYSIS AND LIFE SAFETY
DEMOLITION - PARTIAL FLOOR PLAN
DEMOLITION - PARTIAL FLOOR PLAN
DEMOLITION - PARTIAL REFLECTED CEILING PLAN
DEMOLITION - PARTIAL REFLECTED CEILING PLAN
NEW WORK - OVERALL FLOOR PLAN
NEW WORK - PARTIAL FLOOR PLAN
NEW WORK - PARTIAL FLOOR PLAN
NEW WORK - PARTIAL REFLECTED CEILING PLAN
NEW WORK - PARTIAL REFLECTED CEILING PLAN
INTERIOR ELEVATIONS
TOILET ROOM ENLARGED PLANS AND ELEVATIONS
TOILET ROOM ENLARGED PLANS AND ELEVATIONS
MILLWORK ENLARGED PLANS AND INTERIOR ELEVATIONS
MILLWORK DETAILS
CEILING AND THRESHOLD DETAILS
SIGNAGE PLANS AND SCHEDULE
PARTITION SCHEDULE
DOOR SCHEDULE AND DETAILS
INTERIOR STOREFRONT SCHEDULE AND DETAILS
INTERIOR STOREFRONT SCHEDULE
FINISH SCHEDULE
NEW WORK - PARTIAL FINISH PLAN
NEW WORK - PARTIAL FINISH PLAN
M-001 M-002 M-101 M-102 M-201 M-202 M-203 M-204 M-401 M-601 M-602
P-401 P-402 P-601
E-001 E-101 E-102 E-103 E-104 E-105 E-201 E-202 E-203 E-204 E-205 E-206 E-401 E-501 E-601
MECHANICAL LEGENDS
MECHANICAL GENERAL NOTES AND ABBREVIATIONS
SECOND FLOOR PART PLAN - MECHANICAL DEMOLITION
SECOND FLOOR PART PLAN - MECHANICAL DEMOLITION
SECOND FLOOR PART PLAN - MECHANICAL
SECOND FLOOR PART PLAN - MECHANICAL
SECOND FLOOR PART PLAN - MECHANICAL PIPING
SECOND FLOOR PART PLAN - MECHANICAL PIPING
MECHANICAL PART PLANS
MECHANICAL SCHEDULES AND DETAILS
MECHANICAL CONTROLS
PLUMBING PART PLANS - DEMOLITION
PLUMBING PART PLANS
PLUMBING SCHEDULES, RISERS AND DETAILS
ELECTRICAL LEGEND, ABBREVIATIONS AND GENERAL NOTES
SECOND FLOOR PART PLAN - ELECTRICAL LIGHTING - DEMOLITION
SECOND FLOOR PART PLAN - ELECTRICAL LIGHTING - DEMOLITION
SECOND FLOOR PART PLAN - ELECTRICAL POWER - DEMOLITION
SECOND FLOOR PART PLAN - ELECTRICAL POWER - DEMOLITION
FIRST FLOOR PART PLAN - ELECTRICAL POWER - DEMOLITION
SECOND FLOOR PART PLAN - ELECTRICAL LIGHTING - WORK
SECOND FLOOR PART PLAN - ELECTRICAL LIGHTING - WORK
SECOND FLOOR PART PLAN - ELECTRICAL POWER - WORK
SECOND FLOOR PART PLAN - ELECTRICAL POWER - WORK
SECOND FLOOR PART PLAN - ELECTRICAL LIGHTING - CALCULATIONS
SECOND FLOOR PART PLAN - ELECTRICAL LIGHTING - CALCULATIONS
ELECTRICAL PART PLANS
ELECTRICAL DETAILS
ELECTRICAL SCHEDULES
732 NORTH CAPITOL ST NW
WASHINGTON, DC 20401
FA-001
FA-101
FA-102
FA-201
FA-202
FP-001
FP-101
FP-102
FP-201
FP-202
FIRE ALARM GENERAL NOTES, LEGEND AND ABBREVIATIONS
SECOND FLOOR PART PLAN - FIRE ALARM DEMOLITION
SECOND FLOOR PART PLAN - FIRE ALARM DEMOLITION
SECOND FLOOR PART PLAN - FIRE ALARM
SECOND FLOOR PART PLAN - FIRE ALARM
FIRE PROTECTION GENERAL NOTES, LEGEND AND ABBREVIATIONS
SECOND FLOOR PART PLAN - FIRE PROTECTION DEMOLITION
SECOND FLOOR PART PLAN - FIRE PROTECTION DEMOLITION
SECOND FLOOR PART PLAN - FIRE PROTECTION
SECOND FLOOR PART PLAN - FIRE PROTECTION
OFFICE/
RESTROOM
FM HVAC/
U.S. GOVERNMENT
PUBLISHING OFFICE
732 NORTH CAPITOL ST, NW
APRIL 2, 2025
22903.001
FINAL SUBMISSION
CONSULTANTS:
PROJECT:
DESCRIPTION
ISSUE:
CHECKED BY:
PROJECT NO:
DATE:
DRAWN BY:
MARK DATE
SHEET TITLE
I HEREBY CERTIFY THAT THESE DOCUMENTS WERE PREPARED OR APPROVED BY ME, AND
THAT I AM A DULY LICENSED PROFESSIONAL ENGINEER UNDER THE LAWS OF THE STATE OF
MARYLAND,
LICENSE NO: _______________________
EXPIRATION DATE: _______________________
PROFESSIONAL CERTIFICATION:
ENGINEERS
ESTABLISHED 1972
Mechanical - Electrical - Fire Protection
8005 Harford Road Baltimore, Maryland 21234-5701
Tel: (410) 668-8000 E-mail: ebl@eblengineers.com
WASHINGTON, DC 20401
GANNETT FLEMING TRANSYSTEMS
300 East Joppa Road Suite 200
Baltimore, MD 21286
410.512.4500 www.transystems.com
MODERNIZATION
G-001
AJK
MPS
COVER SHEET
23408
08/25/2026
G:
\p ro je ct s\
\2
.0
\c ad d\
Bi d
Su bm iss io n\
3.
G-
1.
dw g, /1 1/
1:
:3
AM
, P H
O
LT
H
AU
A-001
GENERAL NOTES AND
CONDITIONS,
ABBREVIATIONS AND
SYMBOLS
GENERAL NOTES & CONDITIONS
1. GENERAL NOTES FOUND ON THIS SHEET APPLY TO ALL DRAWINGS
2. ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH ALL STATE, COUNTY AND LOCAL
CODES, REGULATIONS AND ORDINANCES. MATERIAL EQUIPMENT, INSTALLATION, AND
PROCEDURES SHALL BE IN STRICT ACCORDANCE WITH THE APPLICABLE REQUIREMENTS OF
THE LATEST CURRENT EDITION OF THE REFERENCED DOCUMENTATION.
3. THE INTENT OF THESE DRAWINGS IS FOR THE CONTRACTOR TO PROVIDE ALL LABOR,
MATERIAL, FINISHES, EQUIPMENT, INSTALLATION AND SERVICES NECESSARY FOR AND
INCIDENTAL WITH THE WORK, TO PROVIDE THE OWNER WITH A COMPLETE PROJECT
INCLUSIVE OF ALL SYSTEMS.
4. ACTUAL FIELD CONDITIONS MAY VARY FROM THOSE INDICATED. SHOULD ACTUAL CONDITIONS
DIFFER FROM THOSE ORDINARILY ENCOUNTERED AND GENERALLY RECOGNIZED AS
INHERENT IN WORK OF THE CONTRACTOR PROVIDED FOR IN THE CONTRACT, THE
CONTRACTOR SHALL PROMPTLY, BEFORE CONDITIONS ARE DISTURBED, NOTIFY THE OWNER'S
MANAGER. FAILURE TO DO SO MAY MAY WAIVE THE CONTRACTORS RIGHT TO RECEIVE
ADDITIONAL TIME OR CONSIDERATION DUE TO SUCH CONDITIONS.
5. PRIOR TO INITIATING ANY PORTION OF THE WORK, THE CONTRACTOR SHALL VERIFY ALL
DIMENSIONS AND COORDINATE ALL PORTIONS OF THE CONTRACT DOCUMENTS RELATING TO
THAT PORTION OF THE WORK AND AFFECTING ADJOINING PORTIONS. IF DISCREPANCIES
EXIST, THEY SHALL BE REPORTED TO THE ENGINEER AND OWNER FOR CLARIFICATION
AND/OR RESOLUTION BEFORE COMMENCING SUCH WORK.
6. BY SUBMITTING A BID PROPOSAL, THE CONTRACTOR CERTIFIES THAT THEY HAVE VISITED THE
SITES AND UNDERSTAND THE COMPLETE SCOPE OF WORK, WHICH IS INCLUDED IN THE
PROPOSAL.
7. DEFINITIONS: "PROVIDE" MEANS "FURNISH AND INSTALL". "VERIFY" MEANS "VERIFY IN THE
FIELD AND COORDINATE DIMENSIONS AND DISCREPANCIES."
8. THESE NOTES AND OTHER NOTES ON THE DRAWINGS ARE DIRECTIONS FOR THE
CONTRACTOR'S PERFORMANCE , UNLESS NOTED OTHERWISE (U.N.O). FOR EXAMPLE, THE
VERB "INSTALL" MEANS "CONTRACTOR SHALL INSTALL", "RELOCATE" MEANS "CONTRACTOR
SHALL RELOCATE", ETC.
9. UNLESS NOTED OTHERWISE, NUMBERED DIMENSIONS SHOWN ON DRAWINGS TAKE
PRECEDENCE OVER SCALED DRAWINGS. ALL DIMENSIONS TO BE FIELD VERIFIED.
10. DIMENSIONS OF OPENINGS SHALL BE COORDINATED BY CONTRACTOR WITH EQUIPMENT
REQUIRED. SHOP DRAWINGS SHALL INCLUDE A SCHEDULE OF ACTUAL OPENING DIMENSIONS
AS VERIFIED IN FIELD.
11. DURING THE WORK, ANY CONDITION UNCOVERED THAT CAUSES CONFLICT WITH THE
INTENDED DESIGN MUST BE IMMEDIATELY BROUGHT TO THE ATTENTION OF THE ARCHITECT.
12. CONTRACTOR SHALL STAGE WORK IN SUCH A WAY AS TO ENSURE SAFE EMERGENCY EGRESS
AT ALL TIMES.
13. BEFORE COMMENCING ANY DEMOLITION, THE CONTRACTOR MUST COORDINATE DEMOLITION
WITH THE PROPOSED WORK AND OTHER DISCIPLINES.
14. THE ARCHITECT SHALL HAVE NO RESPONSIBILITY FOR THE DISCOVERY, PRESENCE,
HANDLING, REMOVAL OR DISPOSAL OF, OR EXPOSURE OF PERSONS TO HAZARDOUS
MATERIALS IN ANY FORM AT THE PROJECT SITE, INCLUDING BUT NOT LIMITED TO ASBESTOS, ASBESTOS PRODUCTS, POLYCHLORINATED BIPHENYL (PCB) OR OTHER TOXIC SUBSTANCES.
CONTRACTOR TO CONTACT ARCHITECT AND OWNER IF THESE ITEMS ARE APPARENT OR
SUSPECTED.
15. OPERATIONS WILL NOT START PRIOR TO 7AM AND END BY 5PM. MON-FRI. WEEKENDS TO BE
AUTHORIZED IN WRITING
16. GENERAL CONTRACTOR IS RESPONSIBLE FOR COORDINATING ALL TRADES.
17. CONTRACTOR SHALL BE RESPONSIBLE TO VERIFY AND FAMILIARIZE THEMSELVES WITH
ACTUAL FIELD CONDITIONS ASSOCIATED WITH WORK UNDER THIS CONTRACT PRIOR TO
SUBMITTING THEIR BID.
18. IT IS THE INTENT THAT ALL WORK SHALL BE COMPLETE IN EVERY RESPECT AND THAT
MATERIAL OR WORK SPECIFICALLY NOT INDICATED ON THE DRAWINGS, BUT NECESSARY TO
COMPLETE THE WORK, SHALL BE PROVIDED.
19. PROVIDE ALL NECESSARY COMPONENTS FOR U.L. LISTED THROUGH PENETRATION SYSTEM
AT RATED FLOORS, CEILINGS AND WALL PENETRATIONS IN ORDER TO MAINTAIN THE THE
REQUIRED ASSEMBLY RATING. RATED WALLS AND OPENINGS NOTED ON PLANS.
20. UNLESS OTHERWISE INDICATED ALL PIPING, CONDUIT, DUCTWORK AND SIMILAR SERVICES
SHALL BE CONCEALED. ALL EXPOSED ELECTRICAL CONDUIT, PIPING, WIRING AND HVAC
EQUIPMENT SHALL BE LOCATED TO MINIMIZE VISIBILITY IN AREAS EXPOSED TO STRUCTURE.
WHERE CONDUIT CANNOT BE CONCEALED IN WALLS, FLOORS, ETC, RUN CONDUIT, PIPE AND
WIRING ADJACENT TO COLUMNS VERTICALLY AND BEAMS HORIZONTALLY. MINIMIZE
EXPOSURE TO THE GREATEST EXTENT POSSIBLE. PAINT ALL EXPOSED MATERIALS TO MATCH
SUBSTRATE FOR ALL EXPOSED CONDUIT ALONG WALLS RUN IN DIRECTION TO MINIMIZE
EXPOSURE.
21. CONSTRUCTION NOTES SPECIFICALLY REFER TO ITEMS NOTED WITH NUMBER OR LETTER
DESIGNATIONS ON THE RESPECTIVE DRAWINGS WHERE THE DESIGNATIONS ARE SHOWN.
22. MOISTURE RESISTANT GYPSUM BOARD AT ALL TOILET ROOM, JANITOR'S CLOSETS, KITCHENS
AND LOCATIONS WHERE MILLWORK IS SHOWN WITH SINK, TYPICAL.
23. SEALANT AND BACKER ROD AT ALL EXPANSION JOINTS LOCATED IN STONE VENEER, REFER
TO BUILDING ELEVATIONS FOR JOINT LOCATIONS.
24. SEALANT AND BACKER ROD ALL CONTROL JOINTS ARE LOCATED IN CONCRETE UNIT MASONRY
(CMU) KNEE WALLS, REFER LOCATIONS ON SHEET X. FOR EXPANSION JOINT LOCATIONS NOT
SHOWN ON THE FLOOR PLAN REFER TO PLAN DETAIL SHEETS XX.
25. PROVIDE SEMI RECESSED EXTINGUISHER CABINETS AND EXTINGUISHER AS REQUIRED BY
NFPA 10. REFER TO LIFE SAFETY PLAN FOR DETAILS.
26. ALL TOILET SIZES VARY BASED UPON ADA REQUIREMENTS REFER TO SHEET A401 FOR
ENLARGED PLANS AND INTERIOR ELEVATIONS.
27. ALL PARTITIONS NOT DESIGNATED, TO BE CONSIDERED WALL TYPE "A".
28. ALL DIMENSIONS, NOTES, FINISHES AND FIXTURES SHOWN ON TYPICAL FLOOR PLANS,
SECTIONS, OR DETAILS SHALL APPLY TO ALL SIMILAR, SYMMETRICAL OR OPPOSITE HAND
PLANS, SECTIONS OR DETAILS.
29. ALL DOOR JAMBS SHALL BE LOCATED 4" FROM INTERSECTING WALL, UNLESS NOTED
OTHERWISE.
30. CONTRACTOR TO PROVIDE AND INSTALL EXIT SIGNS AND EMERGENCY LIGHTING AS REQUIRED
BY APPLICABLE CODES. REFER TO DRAWINGS HEREIN FOR LOCATIONS AND DETAILS.
31. GC TO COORDINATE FLOOR DRAIN LOCATION WITH PLUMBING DRAWINGS, CONCRETE TO BE
SLOPED TO FLOOR DRAINS, TYP.
32. INTERIOR DIMENSIONS SHOWN ARE TO FINISH FACE OF WALL, UNLESS NOTED OTHERWISE.
33. SPRINKLER SYSTEM: THE SPRINKLER SYSTEM SHALL BE DESIGNED TO MINIMIZE EXPOSURE IN
GRILLE AND BANQUET ROOMS. SPRINKLER HEADS IN CEILINGS SHALL BE CENTERED IN TILES
OR SYMMETRICALLY LOCATED IN GYPSUM CEILINGS. IN EXPOSED WOOD CEILINGS SPRINKLER
PIPING IS TO BE PAINTED TO MATCH CEILING. SPRINKLER LAYOUT DRAWINGS TO BE
SUBMITTED TO ARCHITECT AND ENGINEER FOR REVIEW.
34. GENERAL CONTRACTOR TO VERIFY ALL EXISTING UTILITIES
35. GAS SERVICE
36. DOMESTIC WATER
37. SERVICE SANITARY
38. SEWER SERVICE
39. ELECTRIC POWER SOURCE
A/C AIR CONDITION
ACC ACCESSIBLE
ACOUS INSUL ACOUSTICAL INSULATION
ACT ACOUSTICAL CEILING TILE
ADDL ADDITIONAL
ADH ADHESIVE
ADJ ADJACENT, ADJOING, ADJUSTABLE
AFF ABOVE FINISHED FLOOR
ALT ALTERNATE
ALUM ALUMINUM
ANOD ANODIZE
APC ACOUSTICAL PANEL CEILING
ARCH ARCHITECT
AV AUDIO VISUAL
BATT BATTEN
BLDG BUILDING
BLKHD BULKHEAD
BOT BOTTOM
CB CERAMIC BASE
CER CERAMIC
CG CORNER GUARD
CJ CONSTRUCTION JOINT, CONTROL JOINT
CL CENTER LINE
CLR CLEAR, COLOR
CMU CONCRETE MASONRY UNIT
COL COLUMN
CONC CONCRETE
CONF CONFERENCE
CONT CONTINUE
COORD COORDINATE
CORR CORRIDOR
CPT CARPET
CT CERAMIC TILE
CTR CENTER
CYL CYLINDER
D DEEP, DEPTH
DEMO DEMOLITION
DF DRINKING FOUNTAIN
DIA DIAMETER
DIM DIMENSION
DIR DIRECTION
DISP DISPENSER
DIST DISTANCE
DIV DIVIDE, DIVISION
DS DOWNSPOUT
DW DISHWASHER
DWG DRAWING
E EAST
EA EACH
EL ELEVATION
ELEC ELECTRIC
ELEV ELEVATION
EQ EQUAL
EQUIP EQUIPMENT
EQUIV EQUIVALENT
EW EACH WAY
EXIST EXISTING
EXT EXTERIOR, EXTERNAL
FD FLOOR DRAIN
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FF FINISH FACE
FF EL FINISH FLOOR ELEVATION
FF&E FURNITURE, FIXTURE, AND EQUIPMENT
FIN FINISH
FIXT FIXTURE
FLR FLOOR
FLR FIN FLOOR FINISH
FLUOR FLUORESCENT
FO FINISHED OPENING
FRP FIBERGLASS REINFORCED PLASTIC
FRZ FREEZER
FT FEET, FIRE TREATED, FOOT
FURN FURNISH, FURNITURE
GA GAGE
GALV GALVANIC, GALVANIZED
GC GENERAL CONTRACTOR
GL GLASS
GLZ GLAZING
GYP GYPSUM
HC HANDICAP
HDPE HIGH DENSITY POLYETHYLENE
HDW HARDWARE
HM HOLLOW METAL
HORIZ HORIZONTAL
HT HEIGHT
HVAC
HEATING, VENTILATING, AND AIR
CONDITIONING
INSTL INSTALL
INSUL INSULATION
INT INTERIOR
JAN JANITOR
L ANGLE, LITER
LAM LAMINATE
LAV LAVATORY
LBS POUND
LED LIGHT EMITTING DIODE
LH LEFT HAND
LIN LINEAR
MAINT MAINTENANCE
MATL MATERIAL
MAX MAXIMUM
MECH MECHANICAL
MEL MELAMINE
MFR MANUFACTURER
MID MIDDLE
MIN MINIMUM, MINUTE
MIRR MIRROR
MISC MISCELLANEOUS
MO MASONRY OPENING
MOD MODIFY
MTL METAL
N NORTH
NA NOT APPLICABLE
NAR NARROW
NIC NOT IN CONTRACT
NOM NOMINAL
NTS NOT TO SCALE
OC ON CENTER
OCC OCCUPY
OD OUTSIDE DIAMETER
OF/CI
OWNER FURNISHED/CONTRACTOR
INSTALLED
OFF OFFICE
OF/OI OWNER FURNISHED/OWNER INSTALLED
OH OVERHANG
OPH OPPOSITE HAND
OPNG OPENING
OPP OPPOSITE
PLAM PLASTIC LAMINATE
PLAS PLASTIC
PLYWD PLYWOOD
PREFAB PREFABRICATE
PREFIN PREFINISH
PREP PREPARATION
PT PAINT, PRESSURE TREATED
QRY QUARRY
QT QUARRY TILE
R RADIUS, RISER
RB RUBBER BASE
RD ROAD, ROOF DRAIN
RECT RECTANGLE
REF REFERENCE, REFRIGERATOR
REINF REINFORCE
REQD REQUIRED
REV REVISION
RFI REQUEST FOR INFORMATION
RH RIGHT HAND
RM ROOM
RO ROUGH OPENING
RT RIGHT
S SOUTH
SC SOLID CORE
SCHED SCHEDULE
SCWD SOLID CORE WOOD DOOR
SF SQUARE FOOT (FEET)
SHT SHEET
SIM SIMILAR
SPEC SPECIFICATION
SQ SQUARE
STC SOUND TRANSMISSION CLASS
STOR STORAGE
STRUCT STRUCTURAL
SUSP SUSPEND
SYM SYMBOL
T TREAD
TEL TELEPHONE
TEMP TEMPORARY
THK THICKNESS
THRES THRESHOLD
THRU THROUGH
TK BD TACKBOARD
TMPD GL TEMPERED GLASS
TV TELEVISION
TYP TYPICAL
UL UNDERWRITERS LABORATORIES
UNO UNLESS NOTED OTHERWISE
UTIL UTILITY
VAR VARIATION, VARIES
VB VINYL BASE
VCT VINYL COMPOSITION TILE
VERT VERTICAL
VIF VERIFY IN FIELD
W WEST, WIDE
W/ WITH
W/O WITHOUT
WB WOOD BASE
WC WALL COVERING, WATER CLOSET
WD WOOD
WH WATER HEATER
WLD WELDED
WM WIRE MESH
WT WEIGHT
ABBREVIATIONS
A501A101
(TYP)
A201A101
(TYP)
A302A101
(TYP)
SCALE: 0" = 0"
SECTION
A101A101
A301A101
A501A101
(TYP)
4 1 A401A101
(TYP)
FLOOR LEVEL
ELEV. 00.00
ROOM NAME
X
W#
P-##
A
DETAIL DRAWING NUMBER
SHEET NUMBER WHERE
SECTION IS DRAWN
SHEET NUMBER WHERE
SECTION IS TAKEN
ADDITIONAL INSTRUCTION
DETAIL SYMBOL
ELEVATION SYMBOL
INTERIOR ELEVATION
SYMBOL WITH
MULTIPLE VIEWS
WALL SECTION SYMBOL
BUILDING SECTION SYMBOL
ENLARGED DETAIL SYMBOL
DRAWING TITLE SYMBOL
PLAN NORTH SYMBOL
FLOOR LEVEL SYMBOL
ROOM NAME & NUMBER
TAG SYMBOL
DOOR TAG SYMBOL
WINDOW TAG SYMBOL
KEYNOTE TAG SYMBOL
EQUIPMENT & FINISH
TAG SYMBOL
WALL TYPE TAG SYMBOL
REVISION TAG &
CLOUD SYMBOL
COLUMN BUBBLE &
COLUMN GRID SYMBOL
INDICATES DIRECTION OF
VIEWING PLANE
INDICATES DIRECTION OF
CUTTING PLANE
INDICATES DIRECTION OF
CUTTING PLANE
MATCH LINE
SEE XX/X-XXX
MATCH LINE &
DRAWING REFERENCE
BREAK LINE SYMBOL
DETAIL SYMBOLS
FLOOR ELEVATION TAG
TO INDICATE FINISHED
FLOOR LEVEL
A201
(TYP)
A302
(TYP)
A401
(TYP)
A
C
BDINTERIOR ELEVATION
SYMBOL
DETAIL ELEVATION
SYMBOL
DETAIL SECTION
SYMBOL
SMALL SECTION
DETAIL SYMBOL
N
PROJECT
NORTH
INDICATION OF
PROJECT NORTH
INDICATION OF
TRUE NORTH
A301
MATERIALS
CMU, CONCRETE
MASONRY UNIT
BRICK
CAST STONE OR
PRECAST CONCRETE
CONCRETE
SAND OR GROUT
RIGID INSULATION
ALUMINUM
STEEL
ENGINEERED WOOD
PLYWOOD
PLYWOOD
(SMALL SCALE)
FINISHED
HARDWOOD
CRUSHED GRAVEL
STONE
COMPACT
FILL EARTH
NATURAL
CUT STONE
WOOD, BLOCKING
& SHIMS
WOOD, FRAMING
& FURRING
BATT INSULATION
METAL DECKING
OFFICE/
RESTROOM
FM HVAC/
U.S. GOVERNMENT
PUBLISHING OFFICE
732 NORTH CAPITOL ST, NW
APRIL 2, 2025
22903.001
FINAL SUBMISSION
CONSULTANTS:
PROJECT:
DESCRIPTION
ISSUE:
CHECKED BY:
PROJECT NO:
DATE:
DRAWN BY:
MARK DATE
SHEET TITLE
I HEREBY CERTIFY THAT THESE DOCUMENTS WERE PREPARED OR APPROVED BY ME, AND
THAT I AM A DULY LICENSED PROFESSIONAL ENGINEER UNDER THE LAWS OF THE STATE OF
MARYLAND,
LICENSE NO: _______________________
EXPIRATION DATE: _______________________
PROFESSIONAL CERTIFICATION:
ENGINEERS
ESTABLISHED 1972
Mechanical - Electrical - Fire Protection
8005 Harford Road
Baltimore, Maryland 21234-5701
Tel: (410) 668-8000
E-mail: ebl@eblengineers.com
WASHINGTON, DC 20401
MODERNIZATION
LM/ PRM
BF
15613
11/26/2026
11" MIN
M
I N
8" MIN
9" MIN
(A)
ELEVATION
(B)
PLAN
M
I N
25" MAX17"-25"
9"
6" MAX
M
I N
(A)
ELEVATION
(B)
PLAN
(A)
HINGED DOOR
32" MIN
90°
42" MIN
M
I N
(E)
HINGE APPROACH,
PULL SIDE
36" MIN
M
I N
(D)
HINGE APPROACH,
PULL SIDE
M
I N
12" MIN
(C)
FRONT APPROACH, PUSH
SIDE, DOOR PROVIDED WITH
BOTH CLOSER AND LATCH
M
I N
(B)
FRONT APPROACH,
PUSH SIDE
M
I N
18" MIN
(A)
FRONT APPROACH,
PULL SIDE
M
I N
22" MIN
(F)
HINGE APPROACH,
PUSH SIDE
(G)
HINGE APPROACH, PUSH
SIDE, DOOR PROVIDED WITH
BOTH CLOSER AND LATCH
M
I N
22" MIN
M
I N
(B)
PUSH SIDE
X > 8"
M
I N
18" MIN
X > 8"
(A)
PULL SIDE
M
I N
12" MIN
(C)
PUSH SIDE, DOOR PROVIDED WITH
BOTH CLOSER AND LATCH
X > 8"
12" MIN 12" MIN
48" MIN
48" MIN
(A) (B)
48" MIN
(C)
(A)
STAIRS
(B)
RAMPS
(C)
WALKING SURFACES
1 1/2" MIN
1 1 /2"
M
IN
12" MIN
12" MIN
12" MIN
X
X
NOTE: X = TREAD DEPTH
AREA OF
REFUGE
3/8" MIN
3/8" MIN
AREA OF
REFUGE
M
I N
M
A X
18" MIN
18" MIN
45°
LIBRARY
24" MIN
M
I N
(H)
LATCH APPROACH,
PULL SIDE
(I)
LATCH APPROACH, PULL
SIDE, DOOR PROVIDED
WITH CLOSER
M
I
N 24" MIN
24" MIN
M
I N
(J)
LATCH APPROACH,
PUSH SIDE
(K)
LATCH APPROACH, PUSH
SIDE, DOOR PROVIDED
WITH CLOSER
24" MIN
M
I N
" M
AX
" M
AX
>20"-25" MAX20" MAX
(A) (B)
10" MAX
" M
AX
" M
IN
10" MAX
" M
AX
" M
AX
" M
AX
" M
AX
> 10"-24" MAX
(A) (B)
" M
IN
" M
AX
FIGURE 404.2.4.1 MANEUVERING CLEARANCES
AT MANUAL SWINGING DOORS AND GATES
FIGURE 404.2.3 CLEAR
WIDTH OF DOORWAY
(B)
SIDE APPROACH
M
I N
FIGURE 404.2.4.2 MANEUVERING CLEARANCE
AT DOORWAYS WITHOUT DOOR
FIGURE 404.2.4.3 MANEUVERING CLEARANCES
AT RECESSED DOORS AND GATES
FIGURE 404.2.6 DOORS IN SERIES
AND GATES IN SERIES
X < 4"
FIGURE 405.9.1 EXTENDED
FLOOR OR GROUND SURFACE
EDGE PROTECTION
FIGURE 405.9.2 CURB OR
BARRIER EDGE PROTECTION
FIGURE 505.4 HANDRAIL HEIGHT
FIGURE 505.5 HANDRAIL
CLEARANCE
FIGURE 505.6 HORIZONTAL
PROJECTIONS BELOW
GRIPPING SURFACE
FIGURE 505.10.1 TOP AND BOTTOM
HANDRAIL EXTENSION AT RAMPS
FIGURE 505.10.2 TOP HANDRAIL
EXTENSION AT STAIRS
FIGURE 505.10.3 BOTTOM
HANDRAIL EXTENSION AT STAIRS
FIGURE 306.3 KNEE CLEARANCEFIGURE 306.2 TOE CLEARANCE
FIGURE 308.2.1
UNOBSTRUCTED FORWARD
REACH
FIGURE 308.2.2
UNOBSTRUCTED HIGH
FORWARD REACH
FIGURE 308.3.1
UNOBSTRUCTED SIDE REACH FIGURE 308.3.2 OBSTRUCTED
HIGH SIDE REACH
FIGURE 703.2.5 HEIGHT OF
RAISED CHARACTERS
FIGURE 703.3.2 POSITION OF
BRAILLE
FIGURE 703.4.1 HEIGHT OF
TACTILE CHARACTERS ABOVE
FINISHED FLOOR OR GROUND
FIGURE 703.4.2 LOCATION OF
TACTILE SIGNS AT DOORS
AREA OF
REFUGE
CL
CENTERED ON
TACTILE
CHARACTERS
M
I N
ROOM SIGNAGE
H E
A D
C
L E
A R
A N
C E
R E
A C
H
R
A N
G E
C O
N T
R O
L S
C O
N T
R O
L S
CABINETS AND FIRE EXTINGUISHERS OUTLETS AND SWITCHES ELEVATOR CONTROLS AND SIGNALS
R E
A C
H
R
A N
G E
M
I N
V I S
I B
E
S
I G
N A
L S
*THIS DIAGRAM ILLUSTRATES TYPICAL ACCESSORIES, FOR REFERENCE ONLY. REFER TO
MANUFACTURER SPECIFICATIONS AND RECOMMENDATIONS FOR SPECIFIC MOUNTING
HEIGHTS. VISIBLE SIGNALS
CALL CONTROLS
M
A X
M
A X
M
A X
MIRROR ABOVE
SINK AND SINK MIRROR SOAP HAND DRYER SURFACE MOUNTED
MULTI-ROLL TOILET
TISSUE DISPENSER
SANITARY NAPKIN
DISPENSER
TOILET SEAT COVER
DISPENSER
SURFACE MOUNTED
SANITARY NAPKIN
DISPOSAL
M
A X
MOP RACK
M
A X
URINAL STANDARD
M
A X
A D
A
HOOK DRINKING FOUNTAIN URINAL ADA
T
O
T
O
M
A X
T
O
T
O
T O
P
O
R
B
A R
1' - 0" 3' - 6"
MAX
39" TO 41
BRACKETS, TYP.
3/4" FIRE RATED
PLYWOOD IN-WALL
BLOCKING
ADJUSTABLE
WIRE SHELVING
GENERAL MOUNTING HEIGHTS - SHELVING
DUPLEX
OUTLET
GENERAL MOUNTING HEIGHTS - CONTROLS AND
RECEPTACLES
TELECOM
OUTLET
SPECIAL
PURPOSE
JUNCTION
BOX
MANUAL
FIRE ALARM
PULL STATION
CARD READER,
LOCAL ALARM, OR
ARMING STATION
DUPLEX OUTLET
@ COUNTER W/
BACKSPLASH
RACEWAY DUPLEX
OUTLET
THERMOSTAT WALL
MOUNTED
PHONE OUTLET
LIGHT SWITCH
& DIMMER
CLOCK OR
CLOCK OUTLET
AUDIBLE
AND/OR
FIRE ALARM
SECURITY
STROBE LIGHT
TV
DUPLEX
OUTLETOUTLET VISUAL
GRAB BAR BLOCKING MOUNTING HEIGHTS
REINFORCING AT
TOILET SIDE WALL
REINFORCING BEHIND TOILET
WITH A SIDE WALL
REINFORCING BEHIND TOILET
WITHOUT A SIDE WALL
3' - 6" MIN
5' - 0"
6' MAX
T
O
T O
P
O
R
B
A R
3' - 0" MIN
T O
O
B
L O
C K
I N
G
8"3' - 0"
2' - 2" 1' - 2"
1' - 6"
M I N
A
F
F
O
O
B
L O
C K
I N
G
SIDE ELEVATION FRONT ELEVATION
1' - 6" 1' - 6"
TYPICAL MOUNTING HEIGHTS
VERTICAL CLEARANCE LESS THAN 80"
GUARDRAIL OR OTHER BARRIERPROTRUDING OBJECTS
4" MAX
M
A X
M
I N
V E
R T
I C
E
A R
A N
C E
S
M
I N
V E
R T
I C
E
A R
A N
C E
S
24" MAX 24" MAX48" MIN
M
I N
M
I N
M
A X
LEGEND
DESCRIPTIONCONVENTION
DIMENSION SHOWING ENGLISH UNITS IN
INCHES UNLESS OTHERWISE SPECIFIED,
ABOVE THE LINE.
36"
DIMENSION FOR SMALL MEASUREMENTS
6"
DIMENSION SHOWING A RANGE WITH
MINIMUM - MAXIMUM
33"-36"
MINIMUMMIN.
MAXIMUMMAX.
GREATER THAN
GREATER THAN OR EQUAL TO
LESS THAN
LESS THAN OR EQUAL TO
BOUNDARY OF CLEAR FLOOR SPACE OR
MANEUVERING CLEARANCE
CENTERLINE
A PERMITTED ELEMENT OR ITS EXTENSION
CL
DIRECTION OF TRAVEL OR APPROACH
A WALL, FLOOR, CEILING OR OTHER
ELEMENT CUT IN SECTION OR PLAN
A HIGHLIGHTED ELEMENT IN ELEVATION
OR PLAN
LOCATION ZONE OF ELEMENT CONTROL
OR FEATURE
GENERAL NOTE
1. ALL FIGURES ARE TAKEN FROM THE 2010 ADA STANDARDS
FOR ACCESSIBLE DESIGN.
1. ALL FIGURES SHOWN DEPICT COMMON DESIGN EXAMPLES
AND SOME FIGURES MAY NOT NECESSARY APPLY TO THE
SUBMITTED DRAWINGS.
A-002
TYPICAL ADA CLEARANCES
& MOUNTING HEIGHTS
OFFICE/
RESTROOM
FM HVAC/
U.S. GOVERNMENT
PUBLISHING OFFICE
732 NORTH CAPITOL ST, NW
APRIL 2, 2025
22903.001
FINAL SUBMISSION
CONSULTANTS:
PROJECT:
DESCRIPTION
ISSUE:
CHECKED BY:
PROJECT NO:
DATE:
DRAWN BY:
MARK DATE
SHEET TITLE
I HEREBY CERTIFY THAT THESE DOCUMENTS WERE PREPARED OR APPROVED BY ME, AND
THAT I AM A DULY LICENSED PROFESSIONAL ENGINEER UNDER THE LAWS OF THE STATE OF
MARYLAND,
LICENSE NO: _______________________
EXPIRATION DATE: _______________________
PROFESSIONAL CERTIFICATION:
ENGINEERS
ESTABLISHED 1972
Mechanical - Electrical - Fire Protection
8005 Harford Road
Baltimore, Maryland 21234-5701
Tel: (410) 668-8000
E-mail: ebl@eblengineers.com
WASHINGTON, DC 20401
MODERNIZATION
LM/ PRM
BF
K L 33 32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 45
A
B
C
D
3 2 1
4 3
A216 A222 A215
A220 A2
A
A2
A224
A245E
EL 1
J.C.U.
EL 2
A245AA245B
A245D
A245C
A245 CONF.A2
A
A228
CAPITOL
POLICE
WL WL
LEASED
CARPENTERY
LOCKSMITH
CARPENTRY
PAINT
DIGITAL PRE-PRESSA233
A237
PIPE SHAFT
OFFICES
OFFICE
5 192'147'
123'
130'
FE
FE
FE
FE
FE
FE
FE
FE
FACILITIES/PBM/SIG STAFF
N105 INTER-AGENCY
CONFERENCE CENTER
N100
OPERTION CHIEFS
N101
FACILITIES
DIV CHIEF
N102
PRINT ROOM
& STORAGE
N106
PLANNING &
SCHEDULING
N107
FACILITIES
DEPT. HEAD
N108
BREAK ROOM
N109
PBM
N111
CONFERENCE ROOM
N113
SIG CHIEF
N112
ENGINEERING & AUTOMATION STAFF
N120
AUTO. DIVISION
N116
ENG. DIVISION
N117
BREAK ROOM
N118ENG. & AUTO. DEPT. HEAD
N119
MEETING ROOM
N103
PRINT AREA
N115
INDUS.
CLEANING
A247
UNION AFGE
A246
MEETING ROOM
N104
IT/SERVER
A246B
STORAGE
N114D
STORAGE
N114C
STORAGE
N114B
STORAGE
N114A
CHIEF OF FACILITIES
MANAGEMENT
N110
CONFERENCE STORAGE
N100A
FACILITIES/PBM/SIG STAFF
N105
MECHANICAL
A218A
TOILETS
N123-1 TO N123-12
CORRIDOR C
C-3
CORRIDOR T
123-3
A-003
CODE ANALYSIS & LIFE
SAFETY
SCALE: 1/16" = 1'-0"
LIFE SAFETY PLAN
A003A100
CODE ANALYSIS
Bea
PROJECT ADDRESS:
GOVERNMENT PUBLISHING OFFICE
732 NORTH CAPITOL ST NW
WASHINGTON DC 20401
APPLICABLE CODES
2017 DC CONSTRUCTION CODES WITH LOCAL AMENDMENTS
2021 INTERNATIONAL BUILDING CODE (IBC)
CODE EVALUATION BASED UPON 2018 INTERNATIONAL BUILDING CODE (IBC)
2021 INTERNATIONAL EXISTING BUILDING CODE
2021 NATIONAL ELECTRICAL CODE
2021 INTERNATIONAL FUEL GAS CODE
2021 INTERNATIONAL MECHANICAL CODE
2021 INTERNATIONAL PLUMBING CODE
2021 INTERNATIONAL FIRE CODE
EXISTING BUILDING STATISTICS:
EXISTING BUILDING AREA = LEVEL 2 FACILITIES MANAGEMENT RENOVATION AREA: 15,300 SF
USE GROUP:
B BUSINESS 15,300 S.F. 100%
PROJECT DOES NOT INVOLVE A CHANGE IN OCCUPANCY. PROJECT INVOLVES AN INTERIOR RENOVATION OF A PORTION OF THE BUILDING AREA AND IS THEREFORE CLASSIFIED AS A LEVEL 2 ALTERATION IN THE 2021 INTERNATIONAL EXISTING BUILDING CODE.
INTERNATIONAL BUILDING CODE 2018 REVIEW
CHAPTER 3 OCCUPANCY CLASSIFICATION AND USE, NO CHANGE IN OCCUPANCY FROM EXISTING.
SECTION 304 BUSINESS GROUP B
CHAPTER 5 GENERAL BUILDING HEIGHTS AND AREAS
SECTION 503 GENERAL BUILDING HEIGHT AND AREA UNITS
TYPE IB CONSTRUCTION
TABLE 504.3 ALLOWABLE BUILDING HEIGHT IN FEET ABOVE GRADE
GROUP B, SPRINKLERED:, TYPE IB CONSTRUCTION ALLOWABLE HT = 180'
EXISTING HEIGHT > 75'
TABLE 504.4 ALLOWABLE NUMBER OF STORIES ABOVE GRADE PLANE
GROUP B, SPRINKLERED, TYPE IB CONSTRUCTION = 12 STORIES ALLOWED; EXISTING = 8 STORIES
SECTION 505.3.2 SPRINKLERS SHALL BE LOCATED ABOVE AND BELOW EQUIPMENT PLATFORM.
SECTION 506 BUILDING AREA
TABLE 506.2 ALLOWABLE AREA FACTOR
B, S, UNLIMITED = UNLIMITED SF; EXISTING BUILDING AREA = 15,300
CHAPTER 6 TYPES OF CONSTRUCTION IB
SECTION 602.3 TYPE I CONSTRUCTION IS FIRE-RESISTANT CONSTRUCTION MADE OF NON-COMBUSTIBLE MATERIALS. TYPE I
BUILDINGS ARE TYPICALLY HIGH-RISE OR MULTI-STORY
TABLE 601 FIRE RESISTANCE RATING REQUIREMENTS FOR BUILDING ELEMENTS
TYPE IB CONSTRUCTION SPRINKLERED
PRIMARY STRUCTURAL FRAME 2 HR FIRE RATING
BEARING WALLS EXTERIOR 2 HR FIRE RATING
BEARING WALLS INTERIOR 2 HR FIRE RATING
NON-BEARING WALLS EXTERIOR SEE TABLE 602
NON-BEARING WALLS INTERIOR 0 HR FIRE RATING
FLOOR CONSTRUCTION 2 HR FIRE RATING
ROOF CONSTRUCTION 1 HR FIRE RATING
TABLE 602 FIRE RESISTANCE RATING REQUIREMENTS FOR EXTERIOR WALLS BASED ON FIRE SEPARATION DISTANCE.
X ≥ 30', 0 HR RATING REQUIRED
CHAPTER 7 FIRE AND SMOKE PROTECTION FEATURES
TABLE 705.8 MAXIMUM AREA OF EXTERIOR WALL OPENINGS BASED ON FIRE SEPARATION DISTANCE AND DEGREE OF
OPENING PROTECTION
TABLE 705.8 30 OR GREATER, UNPROTECTED, NONSPRINKLERED, NO LIMIT; COMPLIES
CHAPTER 8 INTERIOR FINISHES
TABLE 803.13 INTERIOR WALL AND CEILING FINISH REQUIREMENTS BY OCCUPANCY
OCCUPANCY GROUP B NON SPRINKLERED
INTERIOR EXIT STAIRWAYS, INTERIOR EXIT RAMPS
AND EXIT PASSAGEWAYS CLASS A
CODE ANALYSIS
CORRIDORS AND ENCLOSURE FOR EXIT ACCESS
STAIRWAYS AND EXIT ACCESS RAMPS CLASS B
ROOMS AND ENCLOSED SPACES CLASS C
SECTION 803.1.3 INTERIOR WALL AND CEILING FINISH
MATERIALS TESTED IN ACCORDANCE WITH ASTM E84 OR UL 723
CLASS A = FLAME SPREAD INDEX:
0-25 SMOKE DEVELOPED INDEX: 0 - 450
CLASS B = FLAME SPREAD INDEX:
26 - 75 SMOKE DEVELOPED INDEX: 0 - 450
CLASS C = FLAME SPREAD INDEX:
76 - 200 SMOKE DEVELOPED INDEX: 0 - 450
SECTION 806 DECORATIVE MATERIALS AND TRIM
SECTION 806.1 GENERAL
1. EXPLOSIVE OR HIGHLY FLAMMABLE MATERIALS SHALL NOT BE USED
2. FURNISHINGS SHALL NOT OBSTRUCT EXITS
SECTION 808 ACOUSTICAL CEILING SYSTEMS
SECTION 808.1.1.1 SUSPENDED ACOUSTICAL CEILINGS
INSTALL FOR ASTM C 635 AND ASTM C 636
ASTM C 635 FOR INTERMEDIATE - DUTY SYSTEM
CHAPTER 10 MEANS OF EGRESS
TABLE 1004.5 REFER TO OCCUPANCY SUMMARY TABLE
SECTION 1005.3.2
THE CAPACITY, IN INCHES, OF MEANS OF EGRESS COMPONENTS OTHER THAN STAIRWAYS SHALL BE CALCULATED BY MULTIPLYING THE OCCUPANT LOAD SERVED BY SUCH COMPONENT BY A MEANS OF
EGRESS CAPACITY OF 0.2 INCH PER OCCUPANT.
EXIT DISCHARGE SERVING SECOND FLOOR OCCUPANTS: 48 OCCUPANTS X 0.2 = 9.6 INCHES
1 EXIT DISCHARGE DOOR = 32" = 32" EGRESS WIDTH; COMPLIES WITH REQUIREMENT
EXIT DISCHARGE SERVING FIRST FLOOR OCCUPANTS: 25 OCCUPANTS X 0.2 = 5 INCHES
1 EXIT DISCHARGE DOOR = 32" = 32" EGRESS WITH, COMPLIES WITH REQUIREMENT
TABLE 1006.3.3 STORIES WITH ONE EXIT
MAXIMUM COMMON PATH OF EGRESS TRAVEL DISTANCE = 65 FEET, COMPLIES
SECTION 1009.3.3 AREA OF REFUGE
STAIRWAYS SHALL EITHER INCORPORATE AN AREA OF REFUGE WITH AN ENLARGED FLOOR-LEVEL LANDING
OR SHALL BE ACCESSED FROM AN AREA OF REFUGE COMPLYING WITH SECTION 1009.6.
AREA OF REFUGE IS INCLUDED
SECTION 1009.6 AREAS OF REFUGE
EVERY REQUIRED AREA OF REFUGE SHALL BE ACCESSIBLE FROM THE SPACE IT SERVES BY AN ACCESSIBLE
MEANS OF EGRESS.
SECTION 1009.6.1 TRAVEL DISTANCE
THE MAX TRAVEL DISTANCE FROM ANY ACCESSIBLE SPACE TO AN AREA OF REFUGE SHALL NOT EXCEED THE EXIT ACCESS TRAVEL DISTANCE PERMITTED FOR THE OCCUPANCY IN ACCORDANCE WITH SECTION 1017.1
SECTION 1010.1.1 SIZE OF DOORS
DOORS SHALL BE 36" WIDE TYPICAL PROVIDING 32" CLEAR WIDTH
SECTION 1010.1.3 DOOR OPENING FORCE 5LB MAXIMUM (PULL AND PUSH SIDES)
SECTION 1010.1.9.1 HARDWARE
SECTION 1010.1.9.4 LOCKS AND LATCHES
ALLOWED FOR GROUP A OCCUPANT LOAD < 300, ALLOWED
SECTION 1010.1.10 PANIC AND FIRE EXIT HARDWARE
GROUP A>50; PANIC DEVICES REQUIRED
EXCEPTION 1: MAIN EXIT MAY HAVE LOADING LOCKING DEVICES
SECTION 1014.8 PROJECTIONS
PROJECTIONS INTO THE REQUIRED WIDTH OF AISLES, STAIRWAYS AND RAMPS AT EACH SIDE SHALL NOT
EXCEED 4 1/2 INCHES.
SECTION 1017 EXIT ACCESS TRAVEL DISTANCE
TABLE 1017.2 EXIT ACCESS TRAVEL DISTANCE
OCCUPANCY B WITH SPRINKLER = 300'
TRAVEL DISTANCE FROM MOST REMOTE LOCATION = 70'±; COMPLIES
TABLE 1020.1 CORRIDOR FIRE-RESISTANCE RATING
OCCUPANCY B WITH SPRINKLER SYSTEM = 0HR RATING, COMPLIES
TABLE 1020.2 MAXIMUM CORRIDOR WIDTH
OCCUPANT LOAD > 50 = 44", 72" WIDTH PROVIDED; COMPLIES
SECTION 1020.4 DEAD ENDS
20' MAXIMUM; COMPLIES
CODE ANALYSIS
CHAPTER 11 ACCESSIBILITY
GENERAL: TOILET ROOMS AND DOORS HAVE BEEN SIZED TO COMPLY WITH REQUIRED CLEARANCES, TURNING RADII, REACH CLEARANCES AND ACCESSIBILITY
PER 2010 ADA STANDARD REFER TO DRAWINGS FOR STANDARD DESIGN DETAILS
CHAPTER 12 INTERIOR ENVIRONMENT
SECTION 1202 VENTILATION
PER INTERNATIONAL MECHANICAL CODE, REFER TO MECHANICAL DRAWINGS FOR CODE COMPLIANCE
INTERNATIONAL INTERNATIONAL EXISTING BUILDING CODE
CHAPTER 8 CLASSIFICATION OF WORK
ALTERATION - LEVEL 2
INCLUDES THE RECONFIGURATION OF A SPACE, THE ADDITION OR ELIMINATION OF ANY DOOR OR WINDOW, THE RECONFIGURATION OR EXTENSION OF ANY SYSTEM, OR THE INSTALLATION OF ANY ADDITIONAL
EQUIPMENT.
SECTION 801.2 COMPLIANCE
IN ADDITION TO THE REQUIREMENTS OF THIS CHAPTER, ALL WORK SHALL COMPLY WITH REQUIREMENTS OF
CHAPTER 7.
SECTION 801.3 NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACE SHALL COMPLY WITH THE
REQUIREMENTS OF THE INTERNATIONAL BUILDING CODE.
SECTION 803 FIRE PROTECTION
SECTION 803.1
THE REQUIREMENTS OF THIS SECTION SHALL BE LIMITED TO WORK AREAS IN WHICH LEVEL 2 ALTERATIONS ARE BEING PERFORMED, AND WHERE SPECIFIED THEY SHALL APPLY THROUGHOUT THE FLOOR ON WHICH
THE WORK AREAS ARE LOCATED OR OTHERWISE BEYOND THE WORK AREA.
SECTION 803.2
AUTOMATIC SPRINKLER SYSTEMS SHALL BE PROVIDED IN ACCORDANCE WITH THE REQUIREMENTS OF SECTIONS 803.2.1 THROUGH 803.2.4 . INSTALLATION REQUIREMENTS SHALL BE IN ACCORDANCE WITH THE
INTERNATIONAL BUILDING CODE.
SECTIONS 803.2.1 &
803.2.2
IN HIGH RISE BUILDINGS AND BUILDINGS WITH OCCUPANCY GROUP B, WORK AREAS THAT HAVE EXITS AND CORRIDORS SHARED BY MORE THAN ONE TENANT OR THAT HAVE EXITS OR CORRIDORS SERVING AN OCCUPANT LOAD GREATER THAN 30 SHALL BE PROVIDED WITH AUTOMATIC SPRINKLER PROTECTION IN THE ENTIRE WORK AREA WHERE THE WORK AREA IS LOCATED ON A FLOOR THAT HAS SUFFICIENT SPRINKLER WATER SUPPLY SYSTEM FROM AN EXISTING STANDPIPE OR A SPRINKLER RISER SERVING THAT FLOOR.
SECTION 803.4
FIRE ALARM AND DETECTION. AN APPROVED FIRE ALARM SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH SECTIONS 803.4.1 THROUGH 803.4.3. WHERE AUTOMATIC SPRINKLER PROTECTION IS PROVIDED IN ACCORDANCE WITH SECTION 803.2 AND IS CONNECTED TO THE BUILDING FIRE SYSTEM, AUTOMATIC HEAT DETECTION SHALL NOT BE REQUIRED. AN APPROVED AUTOMATIC FIRE DETECTION SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH THE PROVISIONS OF THIS CODE AND NFPA 72. DEVICES, COMBINATIONS OF DEVICES, APPLIANCES, AND EQUIPMENT SHALL BE APPROVED. THE AUTOMATIC FIRE DETECTORS SHALL BE SMOKE DETECTORS, EXCEPT THAT AN APPROVED ALTERNATE TYPE OF DETECTOR SHALL BE INSTALLED IN SPACES SUCH AS BOILER ROOMS, WHERE PRODUCTS OF COMBUSTION ARE PRESENT DURING NORMAL
OPERATION IN SUFFICIENT QUANTITY TO ACTUATE A SMOKE DETECTOR.
SECTION 805 MEANS OF EGRESS
SECTION 805.1
THE REQUIREMENTS OF THIS SECTION SHALL BE LIMITED TO WORK AREAS THAT INCLUDE EXITS OR
CORRIDORS SHARED BY MORE THAN ONE TENANT WITHIN THE WORK AREA IN WHICH LEVEL 2
ALTERNATIONS ARE BEING PERFORMED, AND WHERE SPECIFIED THEY SHALL APPLY THROUGHOUT THE
FLOOR ON WHICH THE WORK AREAS ARE LOCATED OR OTHERWISE BEYOND THE WORK AREA.
SECTION 805.2 MEANS OF EGRESS LIGHTING
MEANS OF EGRESS FROM THE HIGHEST WORK AREA FLOOR TO THE FLOOR OF EXIT DISCHARGE SHALL BE PROVIDED WITH ARTIFICIAL LIGHTING WITHIN THE EXIT ENCLOSURE IN ACCORDANCE W/ REQUIREMENTS OF
THE IBC, COMPLIES.
SECTION 805.3 EXIT SIGNS; COMPLIES.
INTERNATIONAL PLUMBING CODE 2018 REVIEW
TABLE 403.1 REFER TO PLUMBING FIXTURE COUNTS TABLE
1 HOUR RATED FIRE SEPARATION -
REFER TO FLOOR PLANS AND WALL
TYPES FOR SPECIFIC UL ASSEMBLIES
45 MINUTE FIRE LABELED DOOR
FE
RECESSED WALL MOUNTED FIRE
EXTINGUISHER
PATH OF TRAVEL TO EXIT
TRAVEL DISTANCE TO EXIT
OCCUPANCY SUMMARY
FUNCTION OF SPACE AREA OCCUPANCY CALCULATION
SF/OCC NSF/GSF CODE OCCUPANCY LOAD NOTES
BUSINESS AREAS
BUSINESS AREAS (ASSEMBLY USE)
13,623 SF
1,353 SF
14,976 SF
150 SF
15 SF
GROSS
NET
PLUMBING FIXTURE COUNTS
TABLE 402.1 2018 INTERNATIONAL PLUMBING CODE
*PLUMBING COUNT FIXTURE COUNT IS FOR THE ENTIRETY OF LEVEL 2 AND INCLUDES EXISTING PLUMBING FIXTURES.
AREA OF LEVEL 2: 140,968 SF
BUSINESS OCCUPANCY COUNT OF LEVEL 2: 940 OCCUPANTS
OCCUPANCY CLASSIFICATION
AND USE GROUP
WATER CLOSETS LAVATORIES DRINKING FOUNTAINS OTHER
BUSINESS OCCUPANCY
(INCLUDES
CONFERENCE ROOMS)
940 OCCUPANTS
1 PER 25 FOR THE FIRST 50 AND 1 PER
50 FOR THE REMAINDER EXCEEDING 50
1 PER 40 FOR THE FIRST 80 AND 1 PER
80 FOR THE REMAINDER EXCEEDING 80 1 PER 100 1 SERVICE SINK
REQUIRED
EXISTING
NEW
TOTAL PROVIDED
9 1 1
12.75
9.4
N 4 48
1/16" = 1'-0" 8 12 18 24 32
CAUTION:
IF THIS DRAWING IS A REDUCTION,
USE THE GRAPHIC SCALE.
OFFICE/
RESTROOM
FM HVAC/
U.S. GOVERNMENT
PUBLISHING OFFICE
732 NORTH CAPITOL ST, NW
APRIL 2, 2025
22903.001
FINAL SUBMISSION
CONSULTANTS:
PROJECT:
DESCRIPTION
ISSUE:
CHECKED BY:
PROJECT NO:
DATE:
DRAWN BY:
MARK DATE
SHEET TITLE
I HEREBY CERTIFY THAT THESE DOCUMENTS WERE PREPARED OR APPROVED BY ME, AND
THAT I AM A DULY LICENSED PROFESSIONAL ENGINEER UNDER THE LAWS OF THE STATE OF
MARYLAND,
LICENSE NO: _______________________
EXPIRATION DATE: _______________________
PROFESSIONAL CERTIFICATION:
ENGINEERS
ESTABLISHED 1972
Mechanical - Electrical - Fire Protection
8005 Harford Road
Baltimore, Maryland 21234-5701
Tel: (410) 668-8000
E-mail: ebl@eblengineers.com
WASHINGTON, DC 20401
MODERNIZATION
LM/ PRM
BF
15613
11/26/2026
ALL-GENDERALL-GENDER
19.8
BUILDING AUTOMATION
A270
K L 33 32 31 30 29 28 27 26 25 24 23 22 21 20 19
B208
CARPENTER SHOP
D.W.
B206
B210
CARPENTER SHOP
B232 ST 21
EL.
EL.
MEN
W
B228
INVENTORY
SH 21 A234
BALING ROOM
6 5
A231 A267
REPRODUCIBLE STORAGE
EL.5 A239
A257
A250 A218
A217
B235
MEZZANINE ABOVE
B233
B233A
B202
B202A
B212 T222
T221 #10
B226
B234A
ENGINEERING
VAULT
A218A
PLATESETTER
MANAGEMENT
CARPENTERY
STORAGE
OF
FI
CE
S
OFFICE
PIPE STORAGE
STORAGE
PRE-PRESS
PRODUCTION
SUPV.
PIPE
PIPE
B201
EL.6
EL.7
STAIR 4A270B A270A A272B A272A
FACILITIES
A272C
A274A
FACILITIES FRONT OFFICE
A274
CONFERENCE
A268
A269
A266A265PHONE ROOM
A273
A271
A264A263
A262
A251
IT
2B-A
A253A
SUPV.
A253B
D-1
D-1
D-1
D-1
D-3D-3D-3
D-4
D-4 D-4
D-9
D-8 D-6
D-7
PARTIALLY
DEMO'D
SPACE
D-1 D-1 D-1 D-1
D-1
D-10D-1D-10D-1 D-1
AD101
DEMOLITION - PARTIAL
FLOOR PLAN
SCALE: 1/8" = 1'-0"
DEMOLITION FLOOR PLAN
AD101AD101
EXISTING CONSTRUCTION TO BE REMOVED.
EXISTING CONSTRUCTION TO REMAIN.
EXISTING DOORS & FRAMES TO REMAIN
EXISTING DOORS & FRAMES TO BE REMOVED.
1.
2.
3.
4.
5.
7.
6.
EXISTING SPRINKLER HEADS TO REMAIN, BE ROTATED TO NEW
LOCATION, REMOVED OR ADDED
EXISTING SUPPLY REGISTER
EXISTING RETURN OR LOUVER REGISTER
EXISTING 2' X 2' LIGHT FIXTURE
EXISTING 2' X 4' LIGHT FIXTURE, DEMOLISHED LIGHTS TO BE
SALVAGED, STORED ON SITE FOR REUSE IN CONSTRUCTION PHASE.
EXISTING RECESSED DOWNLIGHT FIXTURE, DEMOLISHED LIGHTS TO BE
SALVAGED, STORED ON SITE FOR REUSE IN CONSTRUCTION PHASE.
EXISTING EXIT SIGN
EXISTING EMERGENCY LIGHT
DEMOLITION LEGENDGENERAL DEMOLITION NOTES
REFER TO EXISTING MECHANICAL/ELECTRICAL DRAWINGS FOR
COORDINATION OF EXISTING LIGHTING AND MECHANICAL EQUIPMENT.
REMOVE ALL ADHESIVES FROM CONCRETE FLOOR SLAB TO OBTAIN
LEVEL SURFACE.
VERIFY OVERALL DIMENSIONS PRIOR TO DEMOLITION & NOTIFY ARCHITECT
OF ANY DISCREPANCIES OR UNKNOWN CONDITIONS.
REFER TO EXISTING MECHANICAL & ELECTRICAL DRAWINGS TO FOR DEMOLITION,
RELOCATION & CONNECTIONS TO EXISTING HVAC DUCT SYSTEMS, POWER
DISTRIBUTION SYSTEMS, LIGHTING, & PLUMBING SYSTEMS TO BE REMOVED &
CAPPED.
USE CARE DURING DEMOLITION WORK TO PREVENT DAMAGE TO
EXISTING BUILDING COMPONENTS TO REMAIN.
CAP OFF ALL EXISTING PLUMBING DRAINS & PIPES FLUSH TO FLOOR & WALL.
ALL DEMOLITION WORK SHALL COMPLY WITH IBC 2018
REQUIREMENTS.
CAUTION:
IF THIS DRAWING IS A REDUCTION,
USE THE GRAPHIC SCALES.
1/8"=1'-0" 2416128640
N
KEY PLAN
D-1
D-2
D-3
D-4
D-5
D-7
D-6
DEMOLITION KEYNOTES
EXISTING SHAFTWALLS TO BE REMOVED AND INTERSECTING WALLS TO BE PATCHED
UP AND REPAIRED. EXISTING SHAFT TO BE FILLED IN AT LEVEL 2.
REMOVE EXISTING RESTROOM STALLS.
REMOVE EXISTING WATERCLOSETS AND URINALS.
REMOVE EXISTING CASEWORK, COUNTERTOPS, AND LAVATORIES.
REMOVE EXISTING FLOORING, TYPICAL
REMOVE EXISTING ACOUSTICAL PANEL CEILING AND LIGHTING.
PATCH AND REPAIR DAMAGED WALL OR COLUMN ONCE
INTERSECTING WALL IS REMOVED, TYPICAL THROUGHOUT.
D-8 REMOVE EXISTING RESTROOM ACCESSORIES AND PATCH UP & REPAIR WALLS/
D-9 REMOVE EXISTING PLINTH. REFER TO PLUMBING DRAWINGS FOR PLUMBING
DEMOLITION.
REMOVE EXISTING WOOD PANEL & REPAIR SUBSTRATE FOR NEW FINISH, TYPICAL AT
EXTERIOR WALLS.
OFFICE/
RESTROOM
FM HVAC/
U.S. GOVERNMENT
PUBLISHING OFFICE
732 NORTH CAPITOL ST, NW
APRIL 2, 2025
22903.001
FINAL SUBMISSION
CONSULTANTS:
PROJECT:
DESCRIPTION
ISSUE:
CHECKED BY:
PROJECT NO:
DATE:
DRAWN BY:
MARK DATE
SHEET TITLE
I HEREBY CERTIFY THAT THESE DOCUMENTS WERE PREPARED OR APPROVED BY ME, AND
THAT I AM A DULY LICENSED PROFESSIONAL ENGINEER UNDER THE LAWS OF THE STATE OF
MARYLAND,
LICENSE NO: _______________________
EXPIRATION DATE: _______________________
PROFESSIONAL CERTIFICATION:
ENGINEERS
ESTABLISHED 1972
Mechanical - Electrical - Fire Protection
8005 Harford Road
Baltimore, Maryland 21234-5701
Tel: (410) 668-8000
E-mail: ebl@eblengineers.com
WASHINGTON, DC 20401
MODERNIZATION
LM/ PRM
BF
15613
D-10
22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 45
B
C
D
3 2 1
A267
REPRODUCIBLE STORAGE
EL.5 A239
A257A A257
4 3
A257B
A250 A218
A217
A212
EL
FLOOR ROOF
A208 EL 1
ST
AI
R
J.C.U.
EL 2A202
A203A
A200 A225
A2
A2
EL.3
EL.4
ST
AI
R
EL
T121
T122
A210 A2
A214A
A206A205 A214
A204 A204A A204B
A204C
A201
CONF.
A227A213C
CAPITOL POLICE LEASED
A204D
CAPITOL
POLICE
CAPITOL
POLICE
FOP
A221B
LEASED
LEASED
GPO POLICE
GPO POLICE
UN
IO
N
OPEN TO 1st
A244
UN
IO
N
A218A
PLATESETTER
PRE-PRESS
PRODUCTION
PRE-PRESS
STORAGE STORAGE
OFFICES
OFFICEA239B
STAIR 4
A253A
SUPV.
A253B
A253C A255C A255B A255A
FACILITIES MANAGEMENT
A255
A254 A261
POWER BR. MECHANICAL ROOM
A258 A259
A239A
D-1
D-4 D-5
D-9
D-8 D-6
D-1
D-1
D-3
D-3
D-4
D-4
D-4
D-5
D-5
D-6
D-6
D-8
D-8
D-1 D3
D3
D-1 D-1
D-10
AD102
DEMOLITION - PARTIAL
FLOOR PLAN
SCALE: 1/8" = 1'-0"
DEMOLITION FLOOR PLAN
AD102AD102
CAUTION:
IF THIS DRAWING IS A REDUCTION,
USE THE GRAPHIC SCALES.
1/8"=1'-0" 2416128640
EXISTING CONSTRUCTION TO BE REMOVED.
EXISTING CONSTRUCTION TO REMAIN.
EXISTING DOORS & FRAMES TO REMAIN
EXISTING DOORS & FRAMES TO BE REMOVED.
1.
2.
3.
4.
5.
7.
6.
EXISTING SPRINKLER HEADS TO REMAIN, BE ROTATED TO NEW
LOCATION, REMOVED OR ADDED
EXISTING SUPPLY REGISTER
EXISTING RETURN OR LOUVER REGISTER
EXISTING 2' X 2' LIGHT FIXTURE
EXISTING 2' X 4' LIGHT FIXTURE, DEMOLISHED LIGHTS TO BE
SALVAGED, STORED ON SITE FOR REUSE IN CONSTRUCTION PHASE.
EXISTING RECESSED DOWNLIGHT FIXTURE, DEMOLISHED LIGHTS TO BE
SALVAGED, STORED ON SITE FOR REUSE IN CONSTRUCTION PHASE.
EXISTING EXIT SIGN
EXISTING EMERGENCY LIGHT
DEMOLITION LEGENDGENERAL DEMOLITION NOTES
REFER TO EXISTING MECHANICAL/ELECTRICAL DRAWINGS FOR
COORDINATION OF EXISTING LIGHTING AND MECHANICAL EQUIPMENT.
REMOVE ALL ADHESIVES FROM CONCRETE FLOOR SLAB TO OBTAIN
LEVEL SURFACE.
VERIFY OVERALL DIMENSIONS PRIOR TO DEMOLITION & NOTIFY ARCHITECT
OF ANY DISCREPANCIES OR UNKNOWN CONDITIONS.
REFER TO EXISTING MECHANICAL & ELECTRICAL DRAWINGS TO FOR DEMOLITION,
RELOCATION & CONNECTIONS TO EXISTING HVAC DUCT SYSTEMS, POWER
DISTRIBUTION SYSTEMS, LIGHTING, & PLUMBING SYSTEMS TO BE REMOVED &
CAPPED.
USE CARE DURING DEMOLITION WORK TO PREVENT DAMAGE TO
EXISTING BUILDING COMPONENTS TO REMAIN.
CAP OFF ALL EXISTING PLUMBING DRAINS & PIPES FLUSH TO FLOOR & WALL.
ALL DEMOLITION WORK SHALL COMPLY WITH IBC 2018
REQUIREMENTS.
KEY PLAN
N
D-1
D-2
D-3
D-4
D-5
D-7
D-6
DEMOLITION KEYNOTES
EXISTING SHAFTWALLS TO BE REMOVED AND INTERSECTING WALLS TO BE PATCHED
UP AND REPAIRED. EXISTING SHAFT TO BE FILLED IN AT LEVEL 2.
REMOVE EXISTING RESTROOM STALLS.
REMOVE EXISTING WATERCLOSETS AND URINALS.
REMOVE EXISTING CASEWORK, COUNTERTOPS, AND LAVATORIES.
REMOVE EXISTING FLOORING, TYPICAL
REMOVE EXISTING ACOUSTICAL PANEL CEILING AND LIGHTING.
PATCH AND REPAIR DAMAGED WALL OR COLUMN ONCE
INTERSECTING WALL IS REMOVED, TYPICAL THROUGHOUT.
D-8 REMOVE EXISTING RESTROOM ACCESSORIES AND PATCH UP & REPAIR WALLS/
D-9 REMOVE EXISTING PLINTH. REFER TO PLUMBING DRAWINGS FOR PLUMBING
DEMOLITION.
REMOVE PORTION OF EXISTING CHASE WALLD-10
OFFICE/
RESTROOM
FM HVAC/
U.S. GOVERNMENT
PUBLISHING OFFICE
732 NORTH CAPITOL ST, NW
APRIL 2, 2025
22903.001
FINAL SUBMISSION
CONSULTANTS:
PROJECT:
DESCRIPTION
ISSUE:
CHECKED BY:
PROJECT NO:
DATE:
DRAWN BY:
MARK DATE
SHEET TITLE
I HEREBY CERTIFY THAT THESE DOCUMENTS WERE PREPARED OR APPROVED BY ME, AND
THAT I AM A DULY LICENSED PROFESSIONAL ENGINEER UNDER THE LAWS OF THE STATE OF
MARYLAND,
LICENSE NO: _______________________
EXPIRATION DATE: _______________________
PROFESSIONAL CERTIFICATION:
ENGINEERS
ESTABLISHED 1972
Mechanical - Electrical - Fire Protection
8005 Harford Road
Baltimore, Maryland 21234-5701
Tel: (410) 668-8000
E-mail: ebl@eblengineers.com
WASHINGTON, DC 20401
MODERNIZATION
LM/ PRM
BF
BUILDING AUTOMATION
A270
A270B A270A A272B A272A
FACILITIES
A272C
A274A
FACILITIES FRONT OFFICE
A274
CONFERENCE
A268
A269
A266A265PHONE ROOM
A273
A271
A264A263
A262
A251
IT
2B-A
A253A
SUPV.
A253B
K L 33 32 31 30 29 28 27 26 25 24 23 22 21 20 19
PARTIALLY
DEMO'D
SPACE
D-3
D-3
D-3
AD201
DEMOLITION - PARTIAL
REFLECTED CEILING PLAN
SCALE: 1/8" = 1'-0"
DEMOLITION REFLECTED CEILING PLAN
AD201AD201
CAUTION:
IF THIS DRAWING IS A REDUCTION,
USE THE GRAPHIC SCALES.
1/8"=1'-0" 2416128640
EXISTING CONSTRUCTION TO BE REMOVED.
EXISTING CONSTRUCTION TO REMAIN.
EXISTING DOORS & FRAMES TO REMAIN
EXISTING DOORS & FRAMES TO BE REMOVED.
1.
2.
3.
4.
5.
7.
6.
EXISTING SPRINKLER HEADS TO REMAIN, BE ROTATED TO NEW
LOCATION, REMOVED OR ADDED
EXISTING SUPPLY REGISTER
EXISTING RETURN OR LOUVER REGISTER
EXISTING 2' X 2' LIGHT FIXTURE
EXISTING 2' X 4' LIGHT FIXTURE, DEMOLISHED LIGHTS TO BE
SALVAGED, STORED ON SITE FOR REUSE IN CONSTRUCTION PHASE.
EXISTING RECESSED DOWNLIGHT FIXTURE, DEMOLISHED LIGHTS TO BE
SALVAGED, STORED ON SITE FOR REUSE IN CONSTRUCTION PHASE.
EXISTING EXIT SIGN
EXISTING EMERGENCY LIGHT
DEMOLITION LEGENDGENERAL DEMOLITION NOTES
REFER TO EXISTING MECHANICAL/ELECTRICAL DRAWINGS FOR
COORDINATION OF EXISTING LIGHTING AND MECHANICAL EQUIPMENT.
REMOVE ALL ADHESIVES FROM CONCRETE FLOOR SLAB TO OBTAIN
LEVEL SURFACE.
VERIFY OVERALL DIMENSIONS PRIOR TO DEMOLITION & NOTIFY ARCHITECT
OF ANY DISCREPANCIES OR UNKNOWN CONDITIONS.
REFER TO EXISTING MECHANICAL & ELECTRICAL DRAWINGS TO FOR DEMOLITION,
RELOCATION & CONNECTIONS TO EXISTING HVAC DUCT SYSTEMS, POWER
DISTRIBUTION SYSTEMS, LIGHTING, & PLUMBING SYSTEMS TO BE REMOVED &
CAPPED.
USE CARE DURING DEMOLITION WORK TO PREVENT DAMAGE TO
EXISTING BUILDING COMPONENTS TO REMAIN.
CAP OFF ALL EXISTING PLUMBING DRAINS & PIPES FLUSH TO FLOOR & WALL.
ALL DEMOLITION WORK SHALL COMPLY WITH IBC 2018
REQUIREMENTS.
KEY PLAN
N
D-1
D-2
D-3
D-4
D-5
D-7
D-6
DEMOLITION KEYNOTES
EXISTING SHAFTWALLS TO BE REMOVED AND INTERSECTING WALLS TO BE PATCHED
UP AND REPAIRED. EXISTING SHAFT TO BE FILLED IN AT LEVEL 2.
REMOVE EXISTING RESTROOM STALLS.
REMOVE EXISTING WATERCLOSETS AND URINALS.
REMOVE EXISTING CASEWORK, COUNTERTOPS, AND LAVATORIES.
REMOVE EXISTING FLOORING, TYPICAL
REMOVE EXISTING ACOUSTICAL PANEL CEILING AND LIGHTING.
PATCH AND REPAIR DAMAGED WALL OR COLUMN ONCE
INTERSECTING WALL IS REMOVED, TYPICAL THROUGHOUT.
D-8 REMOVE EXISTING RESTROOM ACCESSORIES AND PATCH UP & REPAIR WALLS/
D-9 REMOVE EXISTING PLINTH. REFER TO PLUMBING DRAWINGS FOR PLUMBING
DEMOLITION.
OFFICE/
RESTROOM
FM HVAC/
U.S. GOVERNMENT
PUBLISHING OFFICE
732 NORTH CAPITOL ST, NW
APRIL 2, 2025
22903.001
FINAL SUBMISSION
CONSULTANTS:
PROJECT:
DESCRIPTION
ISSUE:
CHECKED BY:
PROJECT NO:
DATE:
DRAWN BY:
MARK DATE
SHEET TITLE
I HEREBY CERTIFY THAT THESE DOCUMENTS WERE PREPARED OR APPROVED BY ME, AND
THAT I AM A DULY LICENSED PROFESSIONAL ENGINEER UNDER THE LAWS OF THE STATE OF
MARYLAND,
LICENSE NO: _______________________
EXPIRATION DATE: _______________________
PROFESSIONAL CERTIFICATION:
ENGINEERS
ESTABLISHED 1972
Mechanical - Electrical - Fire Protection
8005 Harford Road
Baltimore, Maryland 21234-5701
Tel: (410) 668-8000
E-mail: ebl@eblengineers.com
WASHINGTON, DC 20401
MODERNIZATION
LM/ PRM
BF
A253A
SUPV.
A253B
A253C A255C A255B A255A
FACILITIES MANAGEMENT
A255
A254 A261
POWER BR. MECHANICAL ROOM
A258 A259
A239A
22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 45
A
B
C
D
3 2 1
OPEN TO
ABOVE
OPEN TO
ABOVE
D-2
D-2
D-2
D-2
AD202
DEMOLITION - PARTIAL
REFLECTED CEILING PLAN
SCALE: 1/8" = 1'-0"
DEMOLITION - PARTIAL REFLECTED CEILING PLAN
AD102AD102
CAUTION:
IF THIS DRAWING IS A REDUCTION,
USE THE GRAPHIC SCALES.
1/8"=1'-0" 2416128640
EXISTING CONSTRUCTION TO BE REMOVED.
EXISTING CONSTRUCTION TO REMAIN.
EXISTING DOORS & FRAMES TO REMAIN
EXISTING DOORS & FRAMES TO BE REMOVED.
1.
2.
3.
4.
5.
7.
6.
EXISTING SPRINKLER HEADS TO REMAIN, BE ROTATED TO NEW
LOCATION, REMOVED OR ADDED
EXISTING SUPPLY REGISTER
EXISTING RETURN OR LOUVER REGISTER
EXISTING 2' X 2' LIGHT FIXTURE
EXISTING 2' X 4' LIGHT FIXTURE, DEMOLISHED LIGHTS TO BE
SALVAGED, STORED ON SITE FOR REUSE IN CONSTRUCTION PHASE.
EXISTING RECESSED DOWNLIGHT FIXTURE, DEMOLISHED LIGHTS TO BE
SALVAGED, STORED ON SITE FOR REUSE IN CONSTRUCTION PHASE.
EXISTING EXIT SIGN
EXISTING EMERGENCY LIGHT
DEMOLITION LEGENDGENERAL DEMOLITION NOTES
REFER TO EXISTING MECHANICAL/ELECTRICAL DRAWINGS FOR
COORDINATION OF EXISTING LIGHTING AND MECHANICAL EQUIPMENT.
REMOVE ALL ADHESIVES FROM CONCRETE FLOOR SLAB TO OBTAIN
LEVEL SURFACE.
VERIFY OVERALL DIMENSIONS PRIOR TO DEMOLITION & NOTIFY ARCHITECT
OF ANY DISCREPANCIES OR UNKNOWN CONDITIONS.
REFER TO EXISTING MECHANICAL & ELECTRICAL DRAWINGS TO FOR DEMOLITION,
RELOCATION & CONNECTIONS TO EXISTING HVAC DUCT SYSTEMS, POWER
DISTRIBUTION SYSTEMS, LIGHTING, & PLUMBING SYSTEMS TO BE REMOVED &
CAPPED.
USE CARE DURING DEMOLITION WORK TO PREVENT DAMAGE TO
EXISTING BUILDING COMPONENTS TO REMAIN.
CAP OFF ALL EXISTING PLUMBING DRAINS & PIPES FLUSH TO FLOOR & WALL.
ALL DEMOLITION WORK SHALL COMPLY WITH IBC 2018
REQUIREMENTS.
KEY PLAN
N
D-1
D-2
D-3
D-4
D-5
D-7
D-6
DEMOLITION KEYNOTES
EXISTING SHAFTWALLS TO BE REMOVED AND INTERSECTING WALLS TO BE PATCHED
UP AND REPAIRED. EXISTING SHAFT TO BE FILLED IN AT LEVEL 2.
REMOVE EXISTING RESTROOM STALLS.
REMOVE EXISTING WATERCLOSETS AND URINALS.
REMOVE EXISTING CASEWORK, COUNTERTOPS, AND LAVATORIES.
REMOVE EXISTING FLOORING, TYPICAL
REMOVE EXISTING ACOUSTICAL PANEL CEILING AND LIGHTING.
PATCH AND REPAIR DAMAGED WALL OR COLUMN ONCE
INTERSECTING WALL IS REMOVED, TYPICAL THROUGHOUT.
D-8 REMOVE EXISTING RESTROOM ACCESSORIES AND PATCH UP & REPAIR WALLS/
D-9 REMOVE EXISTING PLINTH. REFER TO PLUMBING DRAWINGS FOR PLUMBING
DEMOLITION.
OFFICE/
RESTROOM
FM HVAC/
U.S. GOVERNMENT
PUBLISHING OFFICE
732 NORTH CAPITOL ST, NW
APRIL 2, 2025
22903.001
FINAL SUBMISSION
CONSULTANTS:
PROJECT:
DESCRIPTION
ISSUE:
CHECKED BY:
PROJECT NO:
DATE:
DRAWN BY:
MARK DATE
SHEET TITLE
I HEREBY CERTIFY THAT THESE DOCUMENTS WERE PREPARED OR APPROVED BY ME, AND
THAT I AM A DULY LICENSED PROFESSIONAL ENGINEER UNDER THE LAWS OF THE STATE OF
MARYLAND,
LICENSE NO: _______________________
EXPIRATION DATE: _______________________
PROFESSIONAL CERTIFICATION:
ENGINEERS
ESTABLISHED 1972
Mechanical - Electrical - Fire Protection
8005 Harford Road
Baltimore, Maryland 21234-5701
Tel: (410) 668-8000
E-mail: ebl@eblengineers.com
WASHINGTON, DC 20401
MODERNIZATION
LM/ PRM
BF
K L 33 32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 45
A
B
C
D
3 2 1
4 3
A216 A222 A215
A220 A2
A
A249
A2
A224
A245E
EL 1
J.C.U.
EL 2
A245AA245B
A245D
A245C
A245 CONF.A2
A
A228
CAPITOL
POLICE
WL WL
LEASED
CARPENTERY
LOCKSMITH
CARPENTRY
PAINT
DIGITAL PRE-PRESSA233
A237
PIPE SHAFT
OFFICES
OFFICE
A-100
NEW WORK - OVERALL
FLOOR PLAN
SCALE: 1/16" = 1'-0"
LEVEL 2 OVERALL FLOOR PLAN
A100A100
EXISTING PARTITION TO REMAIN.
EXISTING WINDOW AND FRAME TO REMAIN.
EXISTING DOOR AND FRAME TO REMAIN.
NEW PARTITION TO BE CONSTRUCTED.
NEW WINDOW AND FRAME TO BE
CONSTRUCTED.
NEW DOOR AND FRAME TO BE CONSTRUCTED.
N 4 48
1/16" = 1'-0" 8 12 18 24 32
CAUTION:
IF THIS DRAWING IS A REDUCTION,
USE THE GRAPHIC SCALE.
NOTE: SHADED AREA INDICATES "NOT IN THIS CONTRACT".
OFFICE/
RESTROOM
FM HVAC/
U.S. GOVERNMENT
PUBLISHING OFFICE
732 NORTH CAPITOL ST, NW
APRIL 2, 2025
22903.001
FINAL SUBMISSION
CONSULTANTS:
PROJECT:
DESCRIPTION
ISSUE:
CHECKED BY:
PROJECT NO:
DATE:
DRAWN BY:
MARK DATE
SHEET TITLE
I HEREBY CERTIFY THAT THESE DOCUMENTS WERE PREPARED OR APPROVED BY ME, AND
THAT I AM A DULY LICENSED PROFESSIONAL ENGINEER UNDER THE LAWS OF THE STATE OF
MARYLAND,
LICENSE NO: _______________________
EXPIRATION DATE: _______________________
PROFESSIONAL CERTIFICATION:
ENGINEERS
ESTABLISHED 1972
Mechanical - Electrical - Fire Protection
8005 Harford Road
Baltimore, Maryland 21234-5701
Tel: (410) 668-8000
E-mail: ebl@eblengineers.com
WASHINGTON, DC 20401
MODERNIZATION
LM/ PRM
BF
15613
REFER TO PARTIAL FLOOR PLAN 1/A-101 REFER TO PARTIAL FLOOR PLAN 1/A-102
PBM
N111
CONFERENCE ROOM
N113
SIG CHIEF
N112
ENGINEERING & AUTOMATION STAFF
N120
AUTO. DIVISION
N116
ENG. DIVISION
N117BREAK ROOM
N118
ENG. & AUTO. DEPT. HEAD
N119
PRINT AREA
N115
STORAGE
N114D
STORAGE
N114C
STORAGE
N114B
STORAGE
N114A
CHIEF OF FACILITIES MANAGEMENT
N110
A502
A502
A502 4
A502
A-312
A312
A300
A502
3 A502
A502
A312
D
A
A
B C C
C
A
B
A
A
A
AA
A
A
A A
A
A
A
A
D
D
B
CC
C
A
6'-0" 14'-5" 6'-0"
9'-1"3'-4"1'-2"
2'-4" 13'-2"
13'-3" 11'-11" 8'-11"
5'-0" 3'-6"
6'-0" 26'-0"
5'-0"
13'-4" 12'-8"
'-6
'-3
5'-
4 1 /2"
'-8
3/ 4" 3'-3"
8'- 4"
9'-
4'-
0"
'-0
8'- 5"
20'-4 5/8"23'-0"85'-3"
7'-6" 4'-8" 7'-4" 4'-9 5/8"
A
B
D D D
B C
B
C
C B B
B
C B B
B
119-1
120-2
117-1 116-1
114D-1 114C-1
114B-1 114A-1
120-1
112-1 111-1
110-1113-1
113-2
CORRIDOR A
C-1
CORRIDOR B
C-2
CORRIDOR B
C-2
CORRIDOR A
C-1
BREAK ROOM
N109
2'- 4"
A
B
B
2'- 4"
2'- 4"
6'-0"
5'- 5"
2'- 5"
6'- 5"
8'-1"10'-8 1/2"
K L 33 32 31 30 29 28 27 26 25 24 23 22 21 20 19
A310
A-401
FE
FE
F-2TYPICALF-1TYPICAL F-1
TYPICAL
F-1TYPICAL
F-2
TYPICAL
AA A
F-3
TYPICAL
F-3
TYPICAL
F-3
TYPICAL
F-3
TYPICAL
ALIGN
C
EXISTING WALL EXISTING WALL
EXISTING WALL
6'- 0" 5'-
9"
A-101
NEW WORK - PARTIAL
FLOOR PLAN1
SCALE: 1/8" = 1'-0"
LEVEL 2 PARTIAL FLOOR PLAN
A101A100
EXISTING PARTITION TO REMAIN.
EXISTING WINDOW AND FRAME TO REMAIN.
EXISTING DOOR AND FRAME TO REMAIN.
NEW PARTITION TO BE CONSTRUCTED.
NEW WINDOW AND FRAME TO BE
CONSTRUCTED.
NEW DOOR AND FRAME TO BE CONSTRUCTED.
FIRE EXTINGUISHER/ CABINET
CAUTION:
IF THIS DRAWING IS A REDUCTION,
USE THE GRAPHIC SCALES.
1/8"=1'-0" 2416128640
N
NOTE: SHADED AREA INDICATES "NOT IN THIS CONTRACT".
OFFICE/
RESTROOM
FM HVAC/
U.S. GOVERNMENT
PUBLISHING OFFICE
732 NORTH CAPITOL ST, NW
APRIL 2, 2025
22903.001
FINAL SUBMISSION
CONSULTANTS:
PROJECT:
DESCRIPTION
ISSUE:
CHECKED BY:
PROJECT NO:
DATE:
DRAWN BY:
MARK DATE
SHEET TITLE
I HEREBY CERTIFY THAT THESE DOCUMENTS WERE PREPARED OR APPROVED BY ME, AND
THAT I AM A DULY LICENSED PROFESSIONAL ENGINEER UNDER THE LAWS OF THE STATE OF
MARYLAND,
LICENSE NO: _______________________
EXPIRATION DATE: _______________________
PROFESSIONAL CERTIFICATION:
ENGINEERS
ESTABLISHED 1972
Mechanical - Electrical - Fire Protection
8005 Harford Road
Baltimore, Maryland 21234-5701
Tel: (410) 668-8000
E-mail: ebl@eblengineers.com
WASHINGTON, DC 20401
MODERNIZATION
LM/ PRM
BF
15613
11/26/2026
FE
F-1
F-2
FLOOR PLAN KEYNOTES
REPAIR/ INSTALL DRYWALL AT ALL WINDOW OPENINGS ALONG THE
EXTTERIOR WALL PERIMETER FOR NEW PAINT FINISH, TYPICAL
PAINT EXTERIOR WINDOW FRAMES & MULLIONS (INTERIOR)- COLOR
P-1,…