_Geotechnical_log-_Dania_Beach.pdf
PDF 3 MB Posted
- Attached to
- Pine Blossom Road Drainage Improvements
- Solicitation number
- 25-012
- Issued by
- Charles County, Florida
About this file
This is a geotechnical engineering report prepared by Terracon Consultants, Inc. for the City of Dania Beach's Southeast Stormwater Improvements project located in Dania Beach, Florida. The report documents subsurface exploration and geotechnical engineering services conducted to support the design of proposed drainage improvements, including exfiltration trenches along SE 3rd and 4th Avenues and two pump stations (approximately 25 feet deep) located near SE 3rd Street/SE 3rd Avenue and SE 4th Avenue between SE 5th and 6th Streets. The scope of work included advancement of five test borings to 10 feet depth, two test borings to 40 feet depth, two exfiltration tests to 10 feet depth, five pavement core samples, and two double ring infiltrometer tests. The report was completed on August 9, 2021, with final certification and sealing by registered Professional Engineers on March 23, 2022.
Subsurface characterization reveals sandy fill material overlying sandy silt with occasional organic peat at depths of 2 to 4 feet, underlain by medium dense sand, weakly cemented limestone formation (6 to 20 feet depth), and loose to medium dense sand extending to 40 feet. Groundwater levels were observed at depths ranging from 2.3 to 3.7 feet below grade. Two exfiltration tests yielded hydraulic conductivity values of 5.62 × 10⁻⁵ and 7.99 × 10⁻⁵ cfs/ft²-ft head at 10 feet depth. Pavement core thicknesses ranged from 2.5 to 3.5 inches across the project area. For pump station design, an allowable bearing pressure of 3,000 psf is recommended on sandy profile at approximately 25 feet depth. The report includes detailed geotechnical soil parameters for sheet pile wall design, construction recommendations for excavation support systems, structural fill specifications, and dewatering considerations. Terracon recommends retention as the Geotechnical Engineer during construction phases to monitor earthwork, verify subsurface conditions, and provide supplemental recommendations for any variations encountered.
View the file
Other files
Show all 33
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
REPORT COVER PAGE
Geotechnical Engineering Report
City of Dania Beach DCP for Southeast Stormwater Improvements Dania Beach, Florida
August 9, 2021 Terracon Project No. 34205040
Prepared for:
WSP, Inc Miami, FL
Prepared by:
Terracon Consultants, Inc.
Fort Lauderdale, FL
Terracon Consultants, Inc. 5371 NW 33 r d Avenue, Suite 201, For t Lauderdale, FL 33309 P (954) 741 8282 F (954) 741 8240 terracon.com
REPORT COVER LETTER TO SIGN
August 9, 2021
WSP, Inc 7650 Corporate Center Drive, Suite 300 Miami, FL 33126
Attn: Mr. Werner J. Reinefeld, P.E., ENV SP P: (954) 847-0622 E: werner.reinefeld@wsp.com
Re: Geotechnical Engineering Report City of Dania Beach DCP for Southeast Stormwater Improvements Area bound from west to the east by Federal Hwy and SE 5th Avenue & From the south to the north from SE 10th Street to SE 2nd Street Dania Beach, Florida Terracon Project No. 34205040
Dear Mr. Reinefeld:
We have completed the Geotechnical Engineering services for the above referenced project. This study was performed in general accordance with Terracon Proposal No. P34205040 dated May 8, 2020. This report presents the findings of the subsurface exploration and provides geotechnical recommendations for the proposed project.
We appreciate the opportunity to be of service to you on this project. If you have any questions concerning this report or if we may be of further service, please contact us.
Sincerely, Terracon Consultants, Inc.
Rutugandha H. Nulkar, P.E. Hugo E. Soto, P.E.
Senior Engineer Principal FL Registration No. 70625 FL Registration No. 36440 hesoto Stamp rhnulkar Text Box This item has been electronically signed and sealed by Hugo E. Soto on March 23, 2022 using a SHA authentication code. Printed copies of this document are not considered signed and sealed and the SHA authentication code must be verified on any electronic copies.
Responsive ■ Resourceful ■ Reliable 1
REPORT TOPICS
INTRODUCTION
SITE CONDITIONS
PROJECT DESCRIPTION
GEOTECHNICAL CHARACTERIZATION
GEOTECHNICAL OVERVIEW
EARTHWORK
PUMP STATION
GEOTECHNICAL SOIL PARAMETERS FOR SHEET PILE WALLS
CONSTRUCTION CONSIDERATIONS FOR PUMP STATION
PAVEMENT EVALUATION
GENERAL COMMENTS
ATTACHMENTS
SITE LOCATION AND EXPLORATION PLANS
EXPLORATION AND TESTING PROCEDURES
EXPLORATION RESULTS
LABORATORY TESTING PROCEDURES
LABORATORY TEST RESULTS
SUPPORTING INFORMATION
Note: Refer to each individual Attachment for a listing of contents.
City of Dania Beach DCP for Southeast Stormwater Improvements Dania Beach, Florida August 9, 2021 ■ Terracon Project No. 34205040
Responsive ■ Resourceful ■ Reliable i
REPORT SUMMARY
Topic 1 Overview Statement 2
Project Description
This project consists of stormwater drainage improvements within the area bound from west to the east by Federal Hwy and SE 5th Avenue and from the south to the North from SE 10th Street to SE 2nd Street in Dania Beach, Florida
Geotechnical Characterization
The borings performed indicate presence of sandy silt at a depth of 2 to 4 feet below the sandy fill material. The sandy silt indicates presence of organic peat at certain locations. Below the silt a layer of medium dense sand is encountered. The sands are underlain by weakly cemented limestone formation that extends to a depth of 15 to 20 feet below existing grade. The limestone formation is underlain by loose to medium dense sands that extend to the termination depth of 40 feet.
Exfiltration Tests
Two (2) exfiltration tests were performed to a depth of 10 feet below grade. The exfiltration test results are presented to assist in the drainage design at the proposed site.
Pump Station We recommend an allowable bearing pressure of 3,000 psf be used for foundation for the pump station bearing on existing sands at an approximate depth of 25 feet below existing grade. We recommend that the dead weight of the structure and the soil directly over the plan area of the footing be used in calculating uplift resistance.
General Comments
This section contains important information about the limitations of this geotechnical engineering report.
1. This summary is for convenience only. It should be used in conjunction with the entire report for design purposes.
Responsive ■ Resourceful ■ Reliable 1
INTRODUC TION
Geotechnical Engineering Report City of Dania Beach DCP for Southeast Stormwater Improvements
Area bound from west to the east by Federal Hwy and SE 5th Avenue & From the South to the North from SE 10th Street to SE 2nd Street
Dania Beach, Florida Terracon Project No. 34205040
August 9, 2021
INTRODUCTION
This report presents the results of our subsurface exploration and geotechnical engineering services performed for the proposed drainage improvements within the Area bound from west to the east by Federal Hwy and SE 5th Avenue & from the South to the North from SE 10th Street to SE 2nd Street in Dania Beach, Florida. The purpose of these services is to provide information and geotechnical engineering recommendations relative to:
■ Subsurface soil (and rock) conditions
■ Groundwater conditions
■ Pavement Core information
■ Exfiltration Test Results
■ Recommendations for the proposed pump stations
The geotechnical engineering Scope of Services for this project included the advancement of five
(5) test borings to depths of 10 feet below existing site grades and two (2) test borings to a depth of 40 feet for the proposed pump station. In addition, two (2) exfiltration tests will be performed to a depth of 10 feet below existing grade. Five (5) pavement cores were performed along the proposed project area. In addition, two Double ring infiltrometer (DRI) tests will be performed at the ground surface at the location selected by WSP USA Inc. The results for the tests will be presented under different cover.
Maps showing the site and boring locations are shown in the Site Location and Exploration Plan sections, respectively.
SITE CONDITIONS
The following description of site conditions is derived from our site visit in association with the field exploration and our review of publicly available geologic and topographic maps.
Item Description
Parcel Information The project is located at Area bound from west to the east by Federal Hwy and SE 5th Avenue & from the South to the North from SE 10th Street to SE 2ns Street in Dania Beach, Florida. (See Exhibit D)
Dania Beach, Florida August 9, 2021 ■ Terracon Project No. 34205040
Responsive ■ Resourceful ■ Reliable 2
PROJECT DESCRIPTION
Our understanding of the project was provided in our proposal.
Item Description Information Provided The project information was provided via emails from WSP
Project Description This project consists of stormwater drainage improvements within the area mentioned above.
Proposed Structure
The following structures are proposed for this project:
a. Exfiltration Trench - Along SE 3rd Avenue – south of SE 3rd Street and SE 4th Avenue – South of SE 5th Street
b. Two (2) Pump Stations - One near the intersection of SE 3rd
Street and SE 3rd Ave. and the other one at SE 4th Avenue between 5th and 6th Street. Approximately 25 ft. deep.
GEOTECHNICAL CHARACTERIZATION
We have developed a general characterization of the subsurface conditions based upon our review of the subsurface exploration, laboratory data, geologic setting and our understanding of the project. The subsurface conditions at the project site can be generalized as follows:
Conditions encountered at each exploration point are indicated on the individual logs. The individual logs can be found in the Exploration Results section can be found in the Figures section of this report.
Stratum No.
Approximate Depth Range to Bottom of
Stratum 1
(Feet)
Material Encountered
(USCS Classification)
Consistency
/Density
1 0.2 to 0.3 Asphalt -
2 2.0 to 4.0 (FILL) Fine SAND with Limerock, light brown (SP/GP) Medium Dense
3 3.5 to 8.0 Light brown sandy SILT occasionally with Black PEAT Soft
Dania Beach, Florida August 9, 2021 ■ Terracon Project No. 34205040
Responsive ■ Resourceful ■ Reliable 3
Stratum No.
Approximate Depth Range to Bottom of
Stratum 1
(Feet)
Material Encountered
(USCS Classification)
Consistency
/Density
4 8.0 to 10.0 FINE SAND to silty fine SAND, light brown to gray
(SP, SP-SM)
Loose to Medium Dense
5 20.0 LIMESTONE with fine to coarse sand Weakly cemented
6 40.0 FINE SAND, light brown to light gray Loose to medium dense
Groundwater
The boreholes were observed while drilling for the presence and level of groundwater. The water table are presented in the table below.
Boring Number Approximate Depth to Groundwater while Drilling (feet) B-1 3.3
B-2 3.4
B-3 3.5
B-4 2.5
B-5 2.3
B-6 3.7
B-7 3.3
These water level observations provide an approximate indication of the groundwater conditions existing at the time the borings were drilled. Fluctuations in groundwater levels can be measured by implementation of a groundwater monitoring plan. Such a plan would include installation of groundwater monitoring wells, and periodic measurement of groundwater levels over a sufficient period of time.
It should be recognized that fluctuations of the groundwater table may occur due to seasonal variations in the amount of rainfall, runoff, tides, and/or other factors. In addition, perched water
Dania Beach, Florida August 9, 2021 ■ Terracon Project No. 34205040
Responsive ■ Resourceful ■ Reliable 4 can develop over low permeability soil strata following periods of heavy or prolonged precipitation.
Groundwater levels during construction or at other times in the life of the structure may be higher or lower than the levels indicated on the boring logs. The possibility of groundwater level fluctuations should be considered when developing the design and construction plans for the project.
Exfiltration Tests
Two (2) exfiltration tests, EX-1 and EX-2, were performed in general accordance with SFWMD Usual Open Hole Test Method. The exfiltration test results are presented in the Attachments.
The exfiltration tests were performed in general accordance with the South Florida Water Management District (SFWMD) procedures for the "Usual Condition Constant Head" exfiltration Tests. The test was performed in a 6-inch diameter borehole. A 2-inch diameter perforated PVC pipe was placed in the borehole. Water was then pumped into the borehole in order to raise the water level in the borehole to the ground surface. Once the inflow stabilized with the outflow rate, the average pumping rate and the elevation of the water obtained with this stabilized flow rate were recorded. The hydraulic conductivity value was then calculated from the test results and is reported in units of cubic feet per second per square foot, per foot of head (cfs/ft2-ft head).
The exfiltration test resulted in a hydraulic conductivity value shown in the table below.
Test No. Depth of Test (ft)
K, Hydraulic Conductivity SFWMD Equation (cfs/ft2-ft Head)
EX-1 10 5.62 x 10-5
EX-2 10 7.99 x 10-5
The exfiltration test locations are shown on the Exploration Plan and the exfiltration results are shown in the Exfiltration Test Results section of the attachments.
Pavement Core Information
The asphalt pavement cores were obtained using a 6-inch diameter core barrel that was attached truck mounted drill rig. The core barrel was advanced by slowly through the asphalt pavement using water to keep the core barrel cool until reaching the surface of the base materials.
The pavement core location and thicknesses are summarized in table on the following page.
Pavement core pictures are presented in the Attachments.
Dania Beach, Florida August 9, 2021 ■ Terracon Project No. 34205040
Responsive ■ Resourceful ■ Reliable 5
Summary of Pavement Core Locations and Thickness
Pavement Core Lane Core Thickness (in)
B-1 L1 3.0 B-2 R1 2.5
B-3 R1 3.5 B-4 R1 2.5 B-7 R1 2.5
GEOTECHNICAL OVERVIEW
Based on the information provided by WSP we anticipate that the pump station will be supported at a depth of approximately 25 feet below existing grade. Based on the results of the subsurface exploration and our analysis the pump station may be supported on an allowable bearing pressure of 3,000 psf on the sandy profile at the proposed depth.
Geotechnical considerations for this project include the following:
EARTHWORK
Earthwork is anticipated to include clearing and grubbing, excavations, and fill placement. The following sections provide recommendations for use in the preparation of specifications for the work. Recommendations include construction considerations.
Site Preparation
The location of any existing underground utility lines within the construction area should be established. Provisions should be made to relocate any interfering utility lines within the construction area. Abandoned utilities should be removed or grouted to reduce the possibility of subsurface erosion.
Dania Beach, Florida August 9, 2021 ■ Terracon Project No. 34205040
Responsive ■ Resourceful ■ Reliable 6
Structural Fill
Fill required to achieve design grade should be classified as structural fill. Earthen materials used for structural fill should meet the following material property requirements:
Fill Type 1 USCS Classification Acceptable Location for Placement
Structural SP, SP-SM or GP, GP-GM (fines content < 12 percent, maximum particle size < 3 inches)
All locations and elevations
Fill Placed Below Groundwater
Inorganic, non-plastic material, free of any man-made debris, with ASTM classification (USCS) of GP, GW or FDOT 57 Stone with less than 5 percent material finer than the No. 200 sieve and a maximum particle size of 3 inches.
The FDOT 57 stone should not be placed more than one foot above the water level.
Below Groundwater
1. Structural and fill should consist of approved materials free of organic matter and debris. A sample of each material type should be submitted to the Geotechnical Engineer for evaluation prior to use on this site.
Fill Compaction Requirements
Structural fill should meet the following compaction requirements.
Item Description
Fill Lift Thickness
Fill lift thicknesses vary with the compaction methods used and should be completed as follows:
■ 12 inches or less in loose thickness when heavy vibratory compaction equipment is used. Maximum particle size should not exceed 3 inches on a 12-inch lift.
■ 4 to 6 inches in loose thickness when hand-guided equipment (i.e.
jumping jack or plate compactor) is used. Maximum particle size should not exceed 1 ½ inches in a 4- to 6-inch lift.
Minimum Compaction Requirements
The area beneath the structure footprint subgrade elevation should be compacted to at least 95 percent of the maximum dry density as determined by the Modified Proctor Test (ASTM D-1557)
Water Content
Range 1 Within +/- 2 percent of optimum moisture content as determined by the Modified Proctor Test, at the time of placement and compaction.
1. We recommend that structural fill be tested for moisture content and compaction during placement. Should the results of the in-place density tests indicate the specified moisture or compaction limits have not been met, the area represented by the test should be reworked and compacted as required until the specified moisture and compaction requirements are achieved.
Dania Beach, Florida August 9, 2021 ■ Terracon Project No. 34205040
Responsive ■ Resourceful ■ Reliable 7
Earthwork Construction Considerations
As a minimum, excavations should be performed in accordance with OSHA 29 CFR, Part 1926, Subpart P, “Excavations” and its appendices, and in accordance with any applicable local, and/or state regulations.
Construction site safety is the sole responsibility of the contractor who controls the means, methods, and sequencing of construction operations. Under no circumstances shall the information provided herein be interpreted to mean Terracon is assuming responsibility for construction site safety, or the contractor's activities; such responsibility shall neither be implied nor inferred.
Weakly to moderately cemented limestone formation is observed from a depth of 6 to 20 feet below existing grade. The excavation of this material may require special tools.
Construction Observation and Testing
The earthwork efforts should be monitored under the direction of the Geotechnical Engineer.
Monitoring should include documentation of adequate removal of excavation, and mitigation of areas to require mitigation.
The continuation of the Geotechnical Engineer into the construction phase of the project provides the continuity to maintain the Geotechnical Engineer’s evaluation of subsurface conditions, including assessing variations and associated design changes.
PUMP STATION
Based on the data obtained from our subsurface exploration, it is our opinion that the proposed pump station can be supported on concrete pad/slab bearing on existing sandy profile. The depth of the pump station is anticipated to be 25 feet below existing ground surface.
Design Recommendations
Based on the existing soil profile, we recommend an allowable bearing pressure of 3,000 psf be used for foundation for the pump station bearing on existing sands.
The pump station will be subjected to hydrostatic uplift forces, particularly when the pump station is empty. As a result, it should be designed to resist these uplift forces. We recommend that the dead weight of the structure and the soil directly over the plan area of the footing be used in calculating uplift resistance. For this calculation, we recommend a soil unit weight of 115 pounds per cubic foot and a safety factor of at least 1.5. Lateral resistance may be calculated by using a
Dania Beach, Florida August 9, 2021 ■ Terracon Project No. 34205040
Responsive ■ Resourceful ■ Reliable 8 coefficient of friction of 0.3 between the bottom of a footing and the underlying limestone formation with a factor of safety of 2.
Foundation Construction Considerations
We understand that the pump station will be supported on a concrete pad/slab. The method of construction of the wet well is unknown at this time.
If concrete seal is used for pump station construction, we recommend that the construction of the concrete seal follow Section 455-15.9 of the FDOT Standard Specifications for Road and Bridge Construction. We also suggest that the general guidelines of Section 125 “Excavation for Structure and Pipe” of the FDOT Standard Specifications be followed for this project.
GEOTECHNICAL SOIL PARAMETERS FOR SHEET PILE WALLS
Based on the SPT borings, recommended soil parameters presented in the Table on the following page were prepared for sheet piles that may be required for the installation of the pump station.
TABLE 1: GEOTECHNICAL SOIL PARAMETERS
General Material
Description
Depth Below Existing Ground Surface (feet)
Unit Weight f
(degr ees)
Cohesion (psf)
Wall Friction
(degrees)
Pressure Coefficients
Total Effective Active Passive At-
Rest
Granular Fill 0 to 2 110 48 32 - 17 0.307 3.25 0.47
Sandy Silt 6 to 7 90 28 29 - 14 0.346 2.88 0.51
Natural Limestone Formation
15 to 20 120 58 - 3000 22 - - -
Sand 40 105 42 30 - 14 0.33 3.00 0.50
Notes: f Angle of internal friction geffective Submerged Unit Weight
CONSTRUCTION CONSIDERATIONS FOR PUMP STATION
Excavation Recommendations
Installation of the pump station will require excavation below existing ground surface. We recommend the use of sheet piles. The soil parameters for the design of the sheet piles are
Dania Beach, Florida August 9, 2021 ■ Terracon Project No. 34205040
Responsive ■ Resourceful ■ Reliable 9 presented in Table 1 of this report. The contractor is advised that during sheet pile installation, refusal conditions may occur within the natural limestone formation. Predrilling may be required in order to prevent refusal conditions and minimize vibrations induced settlements to nearby structures.
The sheet pile installation may produce vibrations noticeable in existing structures and utilities.
We recommend that the Section 108 and 455-1.1 of FDOT Standard Specifications should be followed for the protection of the existing structures and nearby utilities during the sheet pile installation operation. The contractor shall provide surveys and settlement/vibration monitoring of the existing structures and utilities.
An unsupported vertical cut is not considered stable in the given soil conditions due to the upper sandy soil profile. If sheet piles are not considered for construction, based on the subsurface soil conditions, we recommend that for temporary excavations of less than 20 feet; slopes of 1V:2H be used in granular soils, 1V:1H in limestone formation and 1V:3H in silty soils. If steeper slopes are used, the selection and design of an excavation support system is the responsibility of the contractor, and any such system should be designed and sealed by a registered structural engineer and reviewed by a qualified geotechnical engineer. The contractor will be required to comply with all the requirements of the Occupational Safety and Health Administration (OSHA) with regards to excavation support and the protection/ safety of workers entering excavations.
Dewatering Considerations
The need for groundwater control may be anticipated during the construction of the pump station.
The designer should be aware that an unknown quantity of groundwater may have to be pumped from the excavations to help lower the water table to the required depths for the construction of the pump station. A dewatering consultant should be retained to design a dewatering system, if required.
PAVEMENT EVALUATION
Based on the pavement cores performed, the pavement thickness varies between 2.5 to 3.5 feet.
It appears that the existing pavement has undergone some overlays and rehabilitation over time.
Due to the presence of the silt below the existing pavement, it may observe some settlement and cracking issues. It should be anticipated that some maintenance will be required over time. The pavement cores did not show any significant cracking at this time.
Dania Beach, Florida August 9, 2021 ■ Terracon Project No. 34205040
Responsive ■ Resourceful ■ Reliable 10
GENERAL COMMENTS
Our analysis and opinions are based upon our understanding of the project, the geotechnical conditions in the area, and the data obtained from our site exploration. Natural variations will occur between exploration point locations or due to the modifying effects of construction or weather.
The nature and extent of such variations may not become evident until during or after construction.
Terracon should be retained as the Geotechnical Engineer, where noted in this report, to provide observation and testing services during pertinent construction phases. If variations appear, we can provide further evaluation and supplemental recommendations. If variations are noted in the absence of our observation and testing services on-site, we should be immediately notified so that we can provide evaluation and supplemental recommendations.
Our Scope of Services does not include either specifically or by implication any environmental or biological (e.g., mold, fungi, bacteria) assessment of the site or identification or prevention of pollutants, hazardous materials or conditions. If the owner is concerned about the potential for such contamination or pollution, other studies should be undertaken.
Our services and any correspondence or collaboration through this system are intended for the sole benefit and exclusive use of our client for specific application to the project discussed and are accomplished in accordance with generally accepted geotechnical engineering practices with no third-party beneficiaries intended. Any third-party access to services or correspondence is solely for information purposes to support the services provided by Terracon to our client.
Reliance upon the services and any work product is limited to our client, and is not intended for third parties. Any use or reliance of the provided information by third parties is done solely at their own risk. No warranties, either express or implied, are intended or made.
Site characteristics as provided are for design purposes and not to estimate excavation cost. Any use of our report in that regard is done at the sole risk of the excavating cost estimator as there may be variations on the site that are not apparent in the data that could significantly impact excavation cost. Any parties charged with estimating excavation costs should seek their own site characterization for specific purposes to obtain the specific level of detail necessary for costing.
Site safety, and cost estimating including, excavation support, and dewatering requirements/design are the responsibility of others. If changes in the nature, design, or location of the project are planned, our conclusions and recommendations shall not be considered valid unless we review the changes and either verify or modify our conclusions in writing.
Responsive ■ Resourceful ■ Reliable
ATTACHMENTS
SITE LOCATION AND EXPLORATION PLANS
Contents:
Site Location Plan Exploration Plan Exploration and Testing Procedures
Note: All attachments are one page unless noted above.
SITE LOCATION
Dania Beach, FL August 9, 2021 ■ Terracon Project No. 34205040
TOPOGRAPHIC MAP IMAGE COURTESY OF THE U.S. GEOLOGICAL SURVEY
QUADRANGLES INCLUDE: FORT LAUDERDALE SOUTH, FL (1/1/1994) and PORT
EVERGLADES, FL (1/1/1983).
DIAGRAM IS FOR GENERAL LOCATION ONLY, AND IS
NOT INTENDED FOR CONSTRUCTION PURPOSES
SITE
EXPLORATION PLAN
Dania Beach, FL August 9, 2021 ■ Terracon Project No. 34205040
DIAGRAM IS FOR GENERAL LOCATION ONLY, AND IS
NOT INTENDED FOR CONSTRUCTION PURPOSES
AERIAL PHOTOGRAPHY PROVIDED
BY MICROSOFT BING MAPS
LEGEND
Approximate SPT Test Locations
Approximate SPT and Percolation Test Locations
B-1
B-2
B-3
B-4 B-5
B-6/EX-1/RAR-1
B-7/EX-2
Dania Beach, Florida August 9, 2021 ■ Terracon Project No. 34205040
Responsive ■ Resourceful ■ Reliable
EXPLORATION AND TESTING PROCEDURES
Field Exploration
Number of Borings Boring Depth (feet) Planned Location
5 10 Proposed Drainage Improvements
2 40 Proposed Pump Station
2 10 Exfiltration Tests
5 Pavement cores
Boring Layout and Elevations: Unless otherwise noted, Terracon personnel provided the boring layout. Coordinates were obtained with a handheld GPS unit (estimated horizontal accuracy of about ±10 feet).
Subsurface Exploration Procedures: We advanced the borings with a truck-mounted, rotary drill rig. Four samples were obtained in the upper 10 feet of each boring and at intervals of 5 feet thereafter. In the split-barrel sampling procedure, a standard 2-inch outer diameter split-barrel sampling spoon was driven into the ground by a 140-pound automatic hammer falling a distance of 30 inches. The number of blows required to advance the sampling spoon the last 12 inches of a normal 18-inch penetration is recorded as the Standard Penetration Test (SPT) resistance value.
The SPT resistance values, also referred to as N-values, are indicated on the boring logs at the test depths. We observed and recorded groundwater levels during drilling and sampling. For safety purposes, all borings were backfilled with auger cuttings after their completion.
The sampling depths, penetration distances, and other sampling information was recorded on the field boring logs. The samples were placed in appropriate containers and taken to our soil laboratory for testing and classification by a Geotechnical Engineer. Our exploration team prepared field boring logs as part of the drilling operations. These field logs included visual classifications of the materials encountered during drilling and our interpretation of the subsurface conditions between samples. Final boring logs were prepared from the field logs. The final boring logs represent the Geotechnical Engineer's interpretation of the field logs and include modifications based on observations and tests of the samples in our laboratory.
EXPLORATION RESULTS
Contents:
Boring Logs (B-1 through B-7) Exfiltration Test Results Photographs of Pavement Cores
5-4-6-6 N=10
2-1-0-1 N=1
1-0-0-1 N=0
1-1-1-1 N=2
3-5-5-5 N=10
0: Weight of Hammer
ASPHALT, (3"± Thick), black FILL - LIMEROCK (GP), light brown SILTY FINE SAND (SM), brown to gray
SANDY SILT (ML/OL), occasional organics, gray
SANDY SILT (ML), with organics, brown to gray
Boring Terminated at 10 Feet
0.3
2.0
4.0
8.0
10.0
Hammer Type: AutomaticStratification lines are approximate. In-situ, the transition may be gradual.
T H
IS
B
O R
IN
G
L O
G
IS
N O
T V
A
LI
D
IF
S E
P A
R A
T E
D F
R O
M O
R
IG
IN
A
L R
E P
O R
T
G E
O S
M A
R T
L O
G -N
O W
E
LL
0.
G
P J
T E
R R
A C
O N
_D A
T A
T E
M P
LA
T
E .G
D T
/9
/2
W A
T E
R L
E V
E L
O B
S E
R V
A T
IO
N
S
D E
P T
H
F t.)
F
IE
LD
T
E S
T R
E S
U
LT
S
O R
G A
N
IC
C O
N T
E N
T
SE 3rd Ave South of SE 3rd St Dania Beach, FL
SITE:
Advancement Method:
Rotary Mud Drilling and Casing
Abandonment Method:
Boring backfilled with bentonite grout upon completion
Notes:
Project No.: 34205040
Drill Rig: CME 75
Boring Started: 07-29-2021
BORING LOG NO. B-1
WSP USA IncCLIENT:
Miami, FL
Driller: OC/Terracon
Boring Completed: 07-29-2021
Exhibit: A-3
PROJECT: City of Dania Beach DCP for Southeast Stormwater Improvements
16200 NW 59th Ave Ste 106 Miami Lakes, FL
Water initially encountered at 3.3'
WATER LEVEL OBSERVATIONS
P E
R C
E N
T F
IN
E
S
W A
T E
R C
O N
T E
N T
)LOCATION See Exhibit A-2
Latitude: 26.0472° Longitude: -80.1415°
G R
A P
H
IC
L O
G
DEPTH
S A
M P
LE
T
Y P
E
5-7-4-3 N=11
2-1-1-3 N=2
3-3-4-4 N=7
4-4-5-5 N=9
8-8-10-10 N=18
ASPHALT, (2.5"± Thick), black FILL - LIMEROCK (GP), light brown FINE SAND (SP), trace organics, brown to gray SANDY SILT (OL), with organics, brown FINE SAND (SP), brown to light brown
LIMESTONE, with fine sand, light brown to gray
Boring Terminated at 10 Feet
0.2 0.7 2.0
3.5
8.0
10.0
Hammer Type: AutomaticStratification lines are approximate. In-situ, the transition may be gradual.
T H
IS
B
O R
IN
G
L O
G
IS
N O
T V
A
LI
D
IF
S E
P A
R A
T E
D F
R O
M O
R
IG
IN
A
L R
E P
O R
T
G E
O S
M A
R T
L O
G -N
O W
E
LL
0.
G
P J
T E
R R
A C
O N
_D A
T A
T E
M P
LA
T
E .G
D T
/9
/2
W A
T E
R L
E V
E L
O B
S E
R V
A T
IO
N
S
PROJECT: City of Dania Beach DCP for Southeast Stormwater Improvements
16200 NW 59th Ave Ste 106 Miami Lakes, FL
Water initially encountered at 3.4'
WATER LEVEL OBSERVATIONS
P E
R C
E N
T F
IN
E
S
W A
T E
R C
O N
T E
N T
)LOCATION See Exhibit A-2
Latitude: 26.0433° Longitude: -80.1413°
G R
A P
H
IC
L O
G
D E
P T
H
F t.)
F
IE
LD
T
E S
T R
E S
U
LT
S
O R
G A
N
IC
C O
N T
E N
T
SE 3rd Ave South of SE 3rd St Dania Beach, FL
SITE:
Advancement Method:
Rotary Mud Drilling and Casing
Abandonment Method:
Boring backfilled with bentonite grout upon completion
Notes:
Project No.: 34205040
Drill Rig: CME 75
Boring Started: 07-29-2021
BORING LOG NO. B-2
WSP USA IncCLIENT:
Miami, FL
Driller: OC/Terracon
Boring Completed: 07-29-2021
Exhibit: A-4
DEPTH
S A
M P
LE
T
Y
ASPHALT, (3.5"± Thick), black FILL - LIMEROCK (GP), light brown FINE SAND (SP), light brown
LIMESTONE, with fine sand, light brown Boring Terminated at 10 Feet
0.3 1.5
9.5 10.0
23-15-12-10 N=27
6-5-4-4 N=9
3-4-4-5 N=8
3-3-4-4 N=7
4-3-4-9 N=7
Hammer Type: AutomaticStratification lines are approximate. In-situ, the transition may be gradual.
T H
IS
B
O R
IN
G
L O
G
IS
N O
T V
A
LI
D
IF
S E
P A
R A
T E
D F
R O
M O
R
IG
IN
A
L R
E P
O R
T
G E
O S
M A
R T
L O
G -N
O W
E
LL
0.
G
P J
T E
R R
A C
O N
_D A
T A
T E
M P
LA
T
E .G
D T
/9
/2
W A
T E
R L
E V
E L
O B
S E
R V
A T
IO
N
S
DEPTH
D E
P T
H
F t.)
F
IE
LD
T
E S
T R
E S
U
LT
S
O R
G A
N
IC
C O
N T
E N
T
SE 3rd Ave South of SE 3rd St Dania Beach, FL
SITE:
Advancement Method:
Rotary Mud Drilling and Casing
Abandonment Method:
Boring backfilled with bentonite grout upon completion
Notes:
Project No.: 34205040
Drill Rig: CME 75
Boring Started: 07-29-2021
BORING LOG NO. B-3
WSP USA IncCLIENT:
Miami, FL
Driller: OC/Terracon
Boring Completed: 07-29-2021
Exhibit: A-5
PROJECT: City of Dania Beach DCP for Southeast Stormwater Improvements
16200 NW 59th Ave Ste 106 Miami Lakes, FL
Water initially encountered at 3.5'
WATER LEVEL OBSERVATIONS
P E
R C
E N
T F
IN
E
S
W A
T E
R C
O N
T E
N T
)LOCATION See Exhibit A-2
Latitude: 26.0402° Longitude: -80.1412°
G R
A P
H
IC
L O
G
S A
M P
LE
T
Y
7-13-10-6 N=23
2-1-0-0 N=1
1-0-0-0 N=0
1-1-1-1 N=2
3-4-5-5 N=9
0: Weight of Hammer
ASPHALT, (2.5"± Thick), black FILL - LIMEROCK (GP), light brown FILL - FINE SAND (SP), with limerock, light brown SANDY SILT (OL), with organics, light brown to light gray
SANDY SILT (ML), with organics, light brown to light gray
FINE SAND (SP), light brown
Boring Terminated at 10 Feet
0.2 0.7 2.0
6.0
8.0
10.0
Hammer Type: AutomaticStratification lines are approximate. In-situ, the transition may be gradual.
T H
IS
B
O R
IN
G
L O
G
IS
N O
T V
A
LI
D
IF
S E
P A
R A
T E
D F
R O
M O
R
IG
IN
A
L R
E P
O R
T
G E
O S
M A
R T
L O
G -N
O W
E
LL
0.
G
P J
T E
R R
A C
O N
_D A
T A
T E
M P
LA
T
E .G
D T
/9
/2
W A
T E
R L
E V
E L
O B
S E
R V
A T
IO
N
S
D E
P T
H
F t.)
F
IE
LD
T
E S
T R
E S
U
LT
S
O R
G A
N
IC
C O
N T
E N
T
SE 3rd Ave South of SE 3rd St Dania Beach, FL
SITE:
Advancement Method:
Rotary Mud Drilling and Casing
Abandonment Method:
Boring backfilled with bentonite grout upon completion
Notes:
Project No.: 34205040
Drill Rig: CME 75
Boring Started: 07-29-2021
BORING LOG NO. B-4
WSP USA IncCLIENT:
Miami, FL
Driller: OC/Terracon
Boring Completed: 07-29-2021
Exhibit: A-6
PROJECT: City of Dania Beach DCP for Southeast Stormwater Improvements
16200 NW 59th Ave Ste 106 Miami Lakes, FL
Water initially encountered at 2.5'
WATER LEVEL OBSERVATIONS
P E
R C
E N
T F
IN
E
S
W A
T E
R C
O N
T E
N T
)LOCATION See Exhibit A-2
Latitude: 26.0420° Longitude: -80.1403°
G R
A P
H
IC
L O
G
DEPTH
S A
M P
LE
T
Y
4-10-13-10 N=23
6-5-5-4 N=10
2-1-2-2 N=3
2-3-3-3 N=6
8-10-12-12 N=22
TOPSOIL, (4"± Thick), brown FILL - LIMEROCK (GP), light brown FILL - FINE SAND (SP), with limerock, light brown
SANDY SILT (ML), with organics, brown
SANDY SILT (ML), brown
LIMESTONE, with fine sand, light brown
Boring Terminated at 10 Feet
0.3
2.0
4.0
6.0
8.0
10.0
Hammer Type: AutomaticStratification lines are approximate. In-situ, the transition may be gradual.
T H
IS
B
O R
IN
G
L O
G
IS
N O
T V
A
LI
D
IF
S E
P A
R A
T E
D F
R O
M O
R
IG
IN
A
L R
E P
O R
T
G E
O S
M A
R T
L O
G -N
O W
E
LL
0.
G
P J
T E
R R
A C
O N
_D A
T A
T E
M P
LA
T
E .G
D T
/9
/2
W A
T E
R L
E V
E L
O B
S E
R V
A T
IO
N
S
D E
P T
H
F t.)
F
IE
LD
T
E S
T R
E S
U
LT
S
O R
G A
N
IC
C O
N T
E N
T
SE 3rd Ave South of SE 3rd St Dania Beach, FL
SITE:
Advancement Method:
Rotary Mud Drilling and Casing
Abandonment Method:
Boring backfilled with bentonite grout upon completion
Notes:
Project No.: 34205040
Drill Rig: CME 75
Boring Started: 07-29-2021
BORING LOG NO. B-5
WSP USA IncCLIENT:
Miami, FL
Driller: OC/Terracon
Boring Completed: 07-29-2021
Exhibit: A-7
PROJECT: City of Dania Beach DCP for Southeast Stormwater Improvements
16200 NW 59th Ave Ste 106 Miami Lakes, FL
Water initially encountered at 2.3'
WATER LEVEL OBSERVATIONS
P E
R C
E N
T F
IN
E
S
W A
T E
R C
O N
T E
N T
)LOCATION See Exhibit A-2
Latitude: 26.0420° Longitude: -80.1379°
G R
A P
H
IC
L O
G
DEPTH
S A
M P
LE
T
Y
1-2-2-2 N=4
1-1-2-1 N=3
1-1-1-2 N=2
13-8-10-8 N=18
6-6-5-6 N=11
8-8-6 N=14
1-0-1 N=1
1-1-1 N=2
3-3-4 N=7
5-6-8 N=14
10-10-12 N=22
6.6
40.0
68.1
34.5
TOPSOIL (OL), (6"± Thick), brown SANDY SILT (ML), light brown to light gray
SANDY SILT (ML), with organics, light gray
LIMESTONE, with fine sand, light brown
FINE SAND (SP), light brown to light gray
Boring Terminated at 40 Feet
0.5
4.0
6.0
15.0
40.0
Hammer Type: AutomaticStratification lines are approximate. In-situ, the transition may be gradual.
T H
IS
B
O R
IN
G
L O
G
IS
N O
T V
A
LI
D
IF
S E
P A
R A
T E
D F
R O
M O
R
IG
IN
A
L R
E P
O R
T
G E
O S
M A
R T
L O
G -N
O W
E
LL
0.
G
P J
T E
R R
A C
O N
_D A
T A
T E
M P
LA
T
E .G
D T
/9
/2
W A
T E
R L
E V
E L
O B
S E
R V
A T
IO
N
S
D E
P T
H
F t.)
F
IE
LD
T
E S
T R
E S
U
LT
S
O R
G A
N
IC
C O
N T
E N
T
SE 3rd Ave South of SE 3rd St Dania Beach, FL
SITE:
Advancement Method:
Rotary Mud Drilling and Casing
Abandonment Method:
Boring backfilled with bentonite grout upon completion
Notes:
Project No.: 34205040
Drill Rig: CME 75
Boring Started: 07-27-2021
BORING LOG NO. B-6
WSP USA IncCLIENT:
Miami, FL
Driller: OC/Terracon
Boring Completed: 07-28-2021
Exhibit: A-8
PROJECT: City of Dania Beach DCP for Southeast Stormwater Improvements
16200 NW 59th Ave Ste 106 Miami Lakes, FL
Water initially encountered at 3.7'
WATER LEVEL OBSERVATIONS
P E
R C
E N
T F
IN
E
S
W A
T E
R C
O N
T E
N T
)LOCATION See Exhibit A-2
Latitude: 26.0467° Longitude: -80.1395°
G R
A P
H
IC
L O
G
DEPTH
S A
M P
LE
T
Y
12-18-15-13 N=33
3-2-3-2 N=5
2-2-2-3 N=4
2-2-5-8 N=7
8-10-10-12 N=20
6-8-8 N=16
5-5-6 N=11
2-2-3 N=5
3-3-3 N=6
3-3-5 N=8
5-8-10 N=18
ASPHALT, (2.5"± Thick), black FILL - LIMEROCK (GP), light brown SANDY SILT (OL), with organics, light brown to light gray
LIMESTONE, with fine sand, light brown
FINE SAND (SP), light brown
Boring Terminated at 40 Feet
0.2
2.0
7.0
20.0
40.0
Hammer Type: AutomaticStratification lines are approximate. In-situ, the transition may be gradual.
T H
IS
B
O R
IN
G
L O
G
IS
N O
T V
A
LI
D
IF
S E
P A
R A
T E
D F
R O
M O
R
IG
IN
A
L R
E P
O R
T
G E
O S
M A
R T
L O
G -N
O W
E
LL
0.
G
P J
T E
R R
A C
O N
_D A
T A
T E
M P
LA
T
E .G
D T
/9
/2
W A
T E
R L
E V
E L
O B
S E
R V
A T
IO
N
S
D E
P T
H
F t.)
F
IE
LD
T
E S
T R
E S
U
LT
S
O R
G A
N
IC
C O
N T
E N
T
SE 3rd Ave South of SE 3rd St Dania Beach, FL
SITE:
Advancement Method:
Rotary Mud Drilling and Casing
Abandonment Method:
Boring backfilled with bentonite grout upon completion
Notes:
Project No.: 34205040
Drill Rig: CME 75
Boring Started: 07-29-2021
BORING LOG NO. B-7
WSP USA IncCLIENT:
Miami, FL
Driller: OC/Terracon
Boring Completed: 07-29-2021
Exhibit: A-9
PROJECT: City of Dania Beach DCP for Southeast Stormwater Improvements
16200 NW 59th Ave Ste 106 Miami Lakes, FL
Water initially encountered at 3.3'
WATER LEVEL OBSERVATIONS
P E
R C
E N
T F
IN
E
S
W A
T E
R C
O N
T E
N T
)LOCATION See Exhibit A-2
Latitude: 26.0424° Longitude: -80.1372°
G R
A P
H
IC
L O
G
DEPTH
S A
M P
LE
T
Y
SUMMARY OF EXFILTRATION TEST DATA
CITY OF DANIA BEACH DCP FOR SOUTHEAST STORMWATER IMPROVEMENTS
Test No. Date Depth of Saturated Average K, Hydraulic (Boring No.) Performed Hole Hole Depth Flow Rate Conductivity
(Feet) Prior to Test During Test Ds (Feet) (gpm) (cfs/ft2-ft Head)
EX-1 07/27/21 6 2 10 3.7 0.00 6.30 0.40 5.62E-05
EX-2 07/29/21 6 2 10 3.3 0.00 6.70 0.52 7.99E-05
NOTES:
(1) The above hydraulic conductivity values are for a French drain installed to the same depth as the borehole tests. The values represent an ultimate value. The designer should decide on the required factor of safety.
(2) The hydraulic conductivity values were calculated based on the South Florida Water Management Districts's USUAL OPEN HOLE CONSTANT HEAD exfiltration test procedure as shown below.
(3)
(4) Refer to boring logs for subsurface stratification information.
The diameter of the Perforated Casing of 2 inches was used in the computation of the hydraulic conductivity values presented in the above table
Report of Exfiltration Tests
Dania Beach, Florida
TERRACON PROJECT #. 34205040
Diameter Depth to Groundwater Level
Hole (inches)
Perforated Casing (inches)
Below Ground Surface (Feet)
USUAL OPEN-HOLE CONSTANT HEAD EXFILTRATION TEST SCHEMATIC
PHOTOGRAPHS OF PAVEMENT CORES
City of Dania Beach DCP for Southeastern Stormwater Improvements Dania Beach, FL August 9, 2021 ■ Terracon Project No. 34205040
B-1
B-2
Dania Beach, FL August 9, 2021 ■ Terracon Project No. 34205040
B-3
B-4
Dania Beach, FL August 9, 2021 ■ Terracon Project No. 34205040
B-7
LABORATORY RESULTS
Contents:
Laboratory Testing Procedures Laboratory Test Results
LABORATORY TESTING PROCEDURES
Laboratory Testing
The project engineer reviewed the field data and assigned laboratory tests to understand the engineering properties of the various soil and rock strata, as necessary, for this project.
Procedural standards noted below are for reference to methodology in general. In some cases, variations to methods were applied because of local practice or professional judgment.
Standards noted below include reference to other, related standards. Such references are not necessarily applicable to describe the specific test performed.
ASTM D2216 Standard Test Methods for Laboratory Determination of Water (Moisture) Content of Soil and Rock by Mass
ASTM D1140 Standard Test Method for Determining the Amount of Material Finer than 75- Micrometer (No. 200) Sieve in Soils by Washing
ASTM D2974 Standard Test Methods for Determining the Water (Moisture) Content, Ash Content, and Organic Material of Peat and Other Organic Soils
The laboratory testing program often included examination of soil samples by an engineer.
Based on the material’s texture and plasticity, we described and classified the soil samples in accordance with the Unified Soil Classification System. Rock classification was conducted using locally accepted practices for engineering purposes.
B-4 6' - 8' 195.3 82 23 OL
B-5 4' - 6' 96.0 80 7 ML/OL
B-7 6' - 8' 26.0 72 - ML
B-1 4' - 6' 17.0 75 - ML
B-1 6' - 8' 129.4 92 18 OL
B-2 2' - 3.5' - - 24 OL
B-4 4' - 6' 139.1 90 15 OL
Dania Beach, FL
SUMMARY OF LABORATORY TEST RESULTS
City of Dania Beach for Southeast Stormwater Improvements
BORING
NO.
DEPTH
(FT)
MOISTURE
CONTENT (%)
USCS SYMBOL
WASH -
#200 (%)
ORGANIC
CONTENT
SUPPORTING INFORMATION
Contents:
General Notes Unified Soil Classification System Description of Rock Properties
GENERAL NOTES
DESCRIPTION OF SYMBOLS AND ABBREVIATIONS
DESCRIPTIVE SOIL CLASSIFICATION
Soil classification is based on the Unified Soil Classification System. Coarse Grained Soils have more than 50% of their dry weight retained on a #200 sieve; their principal descriptors are: boulders, cobbles, gravel or sand. Fine Grained Soils have less than 50% of their dry weight retained on a #200 sieve; they are principally described as clays if they are plastic, and silts if they are slightly plastic or non-plastic. Major constituents may be added as modifiers and minor constituents may be added according to the relative proportions based on grain size. In addition to gradation, coarse-grained soils are defined on the basis of their in-place relative density and fine-grained soils on the basis of their consistency.
LOCATION AND ELEVATION NOTES
Unless otherwise noted, Latitude and Longitude are approximately determined using a hand-held GPS device. The accuracy of such devices is variable. Surface elevation data annotated with +/- indicates that no actual topographical survey was conducted to confirm the surface elevation. Instead, the surface elevation was approximately determined from topographic maps of the area.
ST
R
EN
G
TH
T
ER
M
S
RELATIVE DENSITY OF COARSE-GRAINED SOILS
(More than 50% retained on No. 200 sieve.)
Density determined by Standard Penetration Resistance
CONSISTENCY OF FINE-GRAINED SOILS
(50% of more passing the No. 200 sieve) Consistency determined by laboratory shear strength testing, field visual-manual procedures or standard penetration resistance
Descriptive Term (Density)
Automatic Hammer SPT N-Value (Blows/Ft.)
Descriptive Term (Consistency)
Unconfined Compressive Strength Qu, (psf)
Automatic Hammer SPT N-Value (Blows/Ft.)
Very Loose < 3 Very Soft Less than 500 < 1 Loose 3 8 Soft 500 to 1,000 1 3
Medium Dense 8 24 Medium Stiff 1,000 to 2,000 3 6 Dense 24 40 Stiff 2,000 to 4,000 6 12
Very Dense > 40 Very Stiff 4,000 to 8,000 12 24 Hard > 8,000 > 24
RELATIVE PROPORTIONS OF SAND AND GRAVEL GRAIN SIZE TERMINOLOGY
Descriptive Term(s) of other constituents Percent of Dry Weight Major Component of
Sample Particle Size
Trace With
Modifier
< 15 15 29
> 30
Boulders Cobble Gravel Sand
Silt or Clay
Over 12 in. (300 mm) 12 in. to 3 in. (300 mm to 75 mm)
3 in. to #4 sieve (75 mm to 4.75 mm) #4 to #200 sieve (4.75mm to 0.075mm)
Passing #200 sieve (0.075mm)
RELATIVE PROPORTIONS OF FINES PLASTICITY DESCRIPTION
Descriptive Term(s) of other consituents Percent of Dry Weight Term
Non-Plastic Low
Medium High
Particle Size
1 10 11 30
> 30
Trace With
Modifier
< 5 5 12 > 12
EXHIBIT C-1
GENERAL NOTES
Description of Rock Properties
WEATHERING
Fresh Rock fresh, crystals bright, few joints may show slight staining. Rock rings under hammer if crystalline.
Very slight Rock generally fresh, joints stained, some joints may show thin clay coatings, crystals in broken face show bright. Rock rings under hammer if crystalline.
Slight Rock generally fresh, joints stained, and discoloration extends into rock up to 1 in. Joints may contain clay. In granitoid rocks some occasional feldspar crystals are dull and discolored. Crystalline rocks ring under hammer.
Moderate Significant portions of rock show discoloration and weathering effects. In granitoid rocks, most feldspars are dull and discolored; some show clayey. Rock has dull sound under hammer and shows significant loss of strength as compared with fresh rock.
Moderately severe All rock except quartz discolored or stained. In granitoid rocks, all feldspars dull and discolored and majority show kaolinization. Rock shows severe loss of strength and can be excavated with geologist’s pick.
Severe All rock except quartz discolored or stained. Rock “fabric” clear and evident, but reduced in strength to strong soil. In granitoid rocks, all feldspars kaolinized to some extent. Some fragments of strong rock usually left.
Very severe All rock except quartz discolored or stained. Rock “fabric” discernible, but mass effectively reduced to “soil” with only fragments of strong rock remaining.
Complete Rock reduced to ”soil”. Rock “fabric” not discernible or discernible only in small, scattered locations. Quartz may be present as dikes or stringers.
HARDNESS (for engineering description of rock – not to be confused with Moh’s scale for minerals)
Very hard Cannot be scratched with knife or sharp pick. Breaking of hand specimens requires several hard blows of geologist’s pick.
Hard Can be scratched with knife or pick only with difficulty. Hard blow of hammer required to detach hand specimen.
Moderately hard Can be scratched with knife or pick. Gouges or grooves to ¼ in. deep can be excavated by hard blow of point of a geologist’s pick. Hand specimens can be detached by moderate blow.
Medium Can be grooved or gouged 1/16 in. deep by firm pressure on knife or pick point. Can be excavated in small chips to pieces about 1-in. maximum size by hard blows of the point of a geologist’s pick.
Soft Can be gouged or grooved readily with knife or pick point. Can be excavated in chips to pieces several inches in size by moderate blows of a pick point. Small thin pieces can be broken by finger pressure.
Very soft Can be carved with knife. Can be excavated readily with point of pick. Pieces 1-in. or more in thickness can be broken with finger pressure. Can be scratched readily by fingernail.
Joint, Bedding and Foliation Spacing in Rocka
Spacing Joints Bedding/Foliation
Less than 2 in. Very close Very thin
2 in. – 1 ft. Close Thin
1 ft. – 3 ft. Moderately close Medium
3 ft. – 10 ft. Wide Thick
More than 10 ft. Very wide Very thick
Rock Quality Designator (RQD)b Joint Openness Descriptors
RQD, as a percentage Diagnostic description Openness Descriptor
Exceeding 90 Excellent No Visible Separation Tight
90 – 75 Good Less than 1/32 in. Slightly Open
75 – 50 Fair 1/32 to 1/8 in. Moderately Open
50 – 25 Poor 1/8 to 3/8 in. Open
Less than 25 Very poor 3/8 in. to 0.1 ft. Moderately Wide
Greater than 0.1 ft. Wide
a. Spacing refers to the distance normal to the planes, of the described feature, which are parallel to each other or nearly so.
b. RQD (given as a percentage) = length of core in pieces 4 in. and longer/length of run.
References: American Society of Civil Engineers. Manuals and Reports on Engineering Practice - No. 56. Subsurface Investigation for Design and
Construction of Foundations of Buildings. New York: American Society of Civil Engineers, 1976.
U.S. Department of the Interior, Bureau of Reclamation, Engineering Geology Field Manual.
Exhibit C-2
Exhibit C-2
UNIFIED SOIL CLASSIFICATION SYSTEM
Criteria for Assigning Group Symbols and Group Names Using Laboratory Tests A Soil Classification
Group Symbol Group Name B
Coarse Grained Soils:
More than 50% retained on No. 200 sieve
Gravels:
More than 50% of coarse fraction retained on No. 4 sieve
Clean Gravels:
Less than 5% fines C
Cu 4 and 1 Cc 3 E GW Well-graded gravel F Cu 4 and/or 1 Cc 3 E GP Poorly graded gravel F
Gravels with Fines:
More than 12% fines C
Fines classify as ML or MH GM Silty gravel F,G,H Fines classify as CL or CH GC Clayey gravel F,G,H
Sands:
50% or more of coarse fraction passes No. 4 sieve
Clean Sands:
Less than 5% fines D
Cu 6 and 1 Cc 3 E SW Well-graded sand I Cu 6 and/or 1 Cc 3 E SP Poorly graded sand I
Sands with Fines:
More than 12% fines D
Fines classify as ML or MH SM Silty sand G,H,I Fines classify as CL or CH SC Clayey sand G,H,I
Fine-Grained Soils:
50% or more passes the No. 200 sieve
Silts and Clays:
Liquid limit less than 50
Inorganic:
PI 7 and plots on or above “A” line J CL Lean clay K,L,M PI 4 or plots below “A” line J ML Silt K,L,M
Organic:
Liquid limit - oven dried
0.75 OL
Organic clay K,L,M,N
Liquid limit - not dried Organic silt K,L,M,O
Silts and Clays:
Liquid limit 50 or more
Inorganic:
PI plots on or above “A” line CH Fat clay K,L,M PI plots below “A” line MH Elastic Silt K,L,M
Organic:
Liquid limit - oven dried
0.75 OH
Organic clay K,L,M,P
Liquid limit - not dried Organic silt K,L,M,Q Highly organic soils: Primarily organic matter, dark in color, and organic odor PT Peat
A Based on the material passing the 3-in. (75-mm) sieve B If field sample contained cobbles or boulders, or both, add “with cobbles or boulders, or both” to group name.
C Gravels with 5 to 12% fines require dual symbols: GW-GM well-graded gravel with silt, GW-GC well-graded gravel with clay, GP-GM poorly graded gravel with silt, GP-GC poorly graded gravel with clay.
D Sands with 5 to 12% fines require dual symbols: SW-SM well-graded sand with silt, SW-SC well-graded sand with clay, SP-SM poorly graded sand with silt, SP-SC poorly graded sand with clay
E Cu = D60/D10 Cc =
DxD
)(D
F If soil contains 15% sand, add “with sand” to group name.
G If fines classify as CL-ML, use dual symbol GC-GM, or SC-SM.
H If fines are organic, add “with organic fines” to group name.
I If soil contains 15% gravel, add “with gravel” to group name.
J If Atterberg limits plot in shaded area, soil is a CL-ML, silty clay.
K If soil contains 15 to 29% plus No. 200, add “with sand” or “with gravel,” whichever is predominant.
L If soil contains 30% plus No. 200 predominantly sand, add “sandy” to group name.
M If soil contains 30% plus No. 200, predominantly gravel, add
“gravelly” to group name.
N PI 4 and plots on or above “A” line.
O PI 4 or plots below “A” line.
P PI plots on or above “A” line.
Q PI plots below “A” line.
EXHIBIT C-3
| 2022-03-23T15:00:19-0400 | |
| Hugo E Soto |