This document is a comprehensive installation manual for the LiftMaster HDSL24UL Commercial DC Vehicular Slide Gate Operator. The manual provides detailed technical specifications, installation instructions, safety guidelines, and operational procedures for a professional-grade gate operator system designed for vehicular access control. Key specifications include compatibility with Class I, II, III, and IV vehicular gate applications, support for gates up to 3,000 lbs with travel distances between 4-75 feet, and a maximum gate travel speed of 1 ft/sec.

The manual emphasizes safety, requiring a minimum of two independent monitored entrapment protection devices for each entrapment zone, and provides extensive guidance on installation, wiring, programming, maintenance, and troubleshooting. The gate operator features include battery backup, solar power compatibility, remote control programming, accessory power outlets, and various control board configuration options for different usage scenarios such as residential, commercial, and industrial applications. Additional features include Timer-to-Close functionality, inherent entrapment protection, and compatibility with various accessories like wireless edge sensors, photoelectric sensors, and loop detectors.

View the file

Other files

File Type Posted
SOW SectionC_FY25ShenagoFenceInstall_7-22.docx DOCX document
Experience Questionnaire.pdf PDF
Wage Determinations mt75.pdf PDF
1240LU25Q0072 Shenango Helibase fencing.pdf PDF
Gooseneck_Padmount_Dimensions.pdf PDF
AK-11_Keypad.pdf PDF
cp4Manual.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

COMMERCIAL DC

VEHICULAR SLIDE GATE OPERATOR

INSTALLATION MANUAL

• THIS PRODUCT MUST BE INSTALLED AND

SERVICED IN ACCORDANCE WITH THIS

MANUAL BY A TRAINED GATE SYSTEMS

TECHNICIAN ONLY.

• This operator is for use on vehicular passage gates ONLY and not intended for use on pedestrian passage gates.

• HDSL24UL is intended for use in Class I, II, III, and IV vehicular slide gate applications.

• Visit LiftMaster.com to locate a professional installing dealer in your area.

• This gate operator is compatible with MyQ® and Security+ 2.0® accessories.

LiftMaster 300 Windsor Drive Oak Brook, IL 60523

Access installation and technical support guides or register this product

Send it in by texting the photo to 71403.

Take a photo of the camera icon including the points ( ).

1.

2.

HDSL24ULTECH

M od el H

D

SL

U

L

SAFETY 2

Safety Symbol and Signal Word Review Usage Class UL325 Entrapment Protection Requirements Safety Installation Information Role of Dealers, Installers, and Trained Gate System Technicians Role of End Users/Home Owners Gate Construction Information

INTRODUCTION 6

Carton Inventory Operator Specifications Site Preparation

INSTALLATION 9

Types of Installations Step 1 Determine Location for Operator Step 2 Install the Operator Step 3 Attach the Chain Step 4 Install Entrapment Protection Step 5 Earth Ground Rod Step 6 Power Wiring Step 7 Connect Batteries Step 8 Dual Gate Setup Step 9 Install the Cover Step 10 Install Warning Signs

ADJUSTMENT 23

Limit, Speed, and Force Adjustment Obstruction Test

PROGRAMMING 26

Remote Controls (Not Provided) LiftMaster Internet Gateway (not provided) CAPXL Connected Access Portal Erase All Codes Erase Limits Constant Pressure Override (CPO) Gate Hold Open Feature To Remove and Erase Monitored Entrapment Protection Devices

OPERATION 29

Gate Operator Setup Examples Control Board Overview Manual Disconnect Reset Switch Relay Adapter Board and Terminal Block Access Operator Alarm Remote Control

ACCESSORY WIRING 33

External Control Devices Locks Miscellaneous Wiring

EXPANSION AND RELAY ADAPTER BOARDS 35

Expansion and Relay Adapter Boards Overview Auxiliary Relays Wiring Accessories to the Expansion Board

MAINTENANCE 38

Important Safety Instructions Maintenance Chart Batteries Drive Train

TROUBLESHOOTING 40

Diagnostic Codes Control Board LEDs Troubleshooting Chart

SOLAR PANELS 45

Step 6 Solar Panel(s)

REPAIR PARTS 49

ACCESSORIES 50

WARRANTY 52

APPENDIX 53

SAMS Wiring With Relays Not Energized Dual Gate Settings Limit Setup With a Remote Control Wiring Diagram Diagnostic Codes Table Site Planning Safety Checklist

WARNING: This product can expose you to chemicals including lead, which are known to the State of California to cause cancer or birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.

When you see these Safety Symbols and Signal Words on the following pages, they will alert you to the possibility of Serious Injury or Death if you do not comply with the warnings that accompany them. The hazard may come from something mechanical or from electric shock.

Read the warnings carefully.

When you see this Signal Word on the following pages, it will alert you to the possibility of damage to your gate and/or the gate operator if you do not comply with the cautionary statements that accompany it. Read them carefully.

IMPORTANT NOTE:

• BEFORE attempting to install, operate or maintain the operator, you must read and fully understand this manual and follow all safety instructions.

• DO NOT attempt repair or service of your gate operator unless you are a Trained Gate

Systems Technician.

MECHANICAL

ELECTRICAL

TABLE OF CONTENTS

SAFETY

Safety Symbol and Signal Word Review

Usage Class Class I - Residential Vehicular Gate Operator A vehicular gate operator (or system) intended for use in garages or parking areas associated with a residence of one-to four single families.

Class II - Commercial/General Access Vehicular Gate A vehicular gate operator (or system) intended for use in a commercial location or building such as a multi-family housing unit (five or more single family units), hotel, garages, retail store, or other buildings accessible by or servicing the general public.

Class III - Industrial/Limited Access Vehicular Gate A vehicular gate operator (or system) intended for use in an industrial location or building such as a factory or loading dock area or other locations not accessible by or intended to service the general public.

Class IV - Restricted Access Vehicular Gate Operator A vehicular gate operator (or system) intended for use in a guarded industrial location or building such as an airport security area or other restricted access locations not servicing the general public, in which unauthorized access is prevented via supervision by security personnel.

UL325 Entrapment Protection Requirements Definitions ENTRAPMENT: The condition when a person is caught or held in a position that increases the risk of injury.

SLIDE GATE ENTRAPMENT ZONE: An entrapment zone exists if at any point during travel, the gap between the gate and any opposing fixed edge or surface such as posts, walls, pillars, columns or the operator itself, is less than 16" (406 mm) in a location up to 6 ft. (1.8 m) above grade.

INDEPENDENT MONITORED ENTRAPMENT PROTECTION DEVICE: An entrapment protection device is independent if it is a different type (photoelectric sensors, edge device, inherent protection device) from the other devices in the same entrapment zone.

Use the Site Planning Safety Checklist in the appendix to identify entrapment zones found in your installation.

Requirements

• A minimum of two independent monitored entrapment protection devices are required to be installed at each entrapment zone.

• It is the responsibility of the installer to install external monitored entrapment protection devices for each entrapment zone.

• The operator will only operate with aminimum of two independent monitored entrapment protection devices installed in each direction;

two in the open direction and two in the closed direction.

This operator has an inherent entrapment protection device built-in.

The installer MUST provide one additional entrapment protection device for each entrapment zone.

Acceptable entrapment protection device types include:

• Inherent (built into the operator)

• LiftMaster monitored external photoelectric sensors, see page 50 for acceptable sensors.

• LiftMaster monitored external edge sensors, see page 50 for acceptable sensors.

IMPORTANT SAFETY

INSTRUCTIONS

To reduce the risk of INJURY or DEATH:

• READ AND FOLLOW ALL INSTRUCTIONS.

• NEVER let children operate or play with gate controls. Keep the remote control away from children.

• ALWAYS keep people and objects away from the gate. NO ONE

SHOULD CROSS THE PATH OF THE MOVING GATE.

• Test the gate operator monthly. The gate MUST reverse on contact with an object or reverse when an object activates the noncontact sensors. After adjusting the speed, force, or the limit of travel, retest the gate operator. Failure to adjust and retest the gate operator properly can increase the risk of INJURY or DEATH.

• Use the manual release ONLY when the gate is not moving.

• KEEP GATES PROPERLY MAINTAINED. Read this manual. Have a Trained Gate Systems Technician make repairs to gate hardware.

• The entrance is for vehicles ONLY. Pedestrians MUST use separate entrance.

• SAVE THESE INSTRUCTIONS.

Safety Installation Information

1. Vehicular gate systems provide convenience and security. Gate systems are comprised of many component parts. The gate operator is only one component. Each gate system is specifically designed for an individual application.

2. Gate operating system designers, installers and users must take into account the possible hazards associated with each individual application. Improperly designed, installed or maintained systems can create risks for the user as well as the bystander. Gate systems design and installation must reduce exposure to potential hazards.

3. A gate operator can create high levels of force in its function as a component part of a gate system. Therefore, safety features must be incorporated into every gate system design. Specific safety features include:

• Edges Sensors (contact)

• Guards for Exposed Rollers

• Photoelectric Sensors

• Screen Mesh

• Instructional and Precautionary Signage

4. Install the gate operator only when:

a. The operator is appropriate for the construction and the usage class of the gate.

b. All openings of a horizontal slide gate are guarded or screened from the bottom of the gate to a minimum of 6 feet (1.8 m) above the ground to prevent a 2-1/4 inches (6 cm) diameter sphere from passing through the openings anywhere in the gate, and in that portion of the adjacent fence that the gate covers in the open position.

c. All exposed pinch points are eliminated or guarded, and guarding is supplied for exposed rollers.

5. The gate operator is intended for installation only on gates used for vehicles. Pedestrians must be supplied with a separate access opening.

The pedestrian access opening shall be designed to promote pedestrian usage. Locate the pedestrian access such that persons will not come in contact with the vehicular gate during the entire path of travel of the vehicular gate.

6. The gate must be installed in a location so that enough clearance is supplied between the gate and adjacent structures when opening and closing to reduce the risk of entrapment.

7. The gate must be properly installed and work freely in both directions prior to the installation of the gate operator.

8. Permanently mounted access controls intended for users to activate, must be located at least 6 feet (1.8 m) away from any moving part of the gate and where the user is prevented from reaching over, under, around or through the gate to operate the controls. Outdoor or easily accessible controls shall have a security feature to prevent unauthorized use. Exception: Emergency access controls only accessible by authorized personnel (e.g. fire, police) may be placed at any location in the line-of-sight of the gate.

9. For a gate operator utilizing a Stop and/or Reset button, it must be located in the line-of-sight of the gate. Activation of the reset control shall not cause the operator to start.

10. A minimum of two (2) WARNING SIGNS shall be installed in the area of the gate. Each warning sign is to be visible by persons located on the side of the gate on which the sign is installed.

11. For a gate operator utilizing a non-contact sensor:

a. See Install Entrapment Protection section for placement of non-contact sensor for each type of application.

b. Care shall be exercised to reduce the risk of nuisance tripping, such as when a vehicle trips the sensor while the gate is still moving.

c. One or more non-contact sensors shall be located where the risk of entrapment or obstruction exists, such as the perimeter reachable by a moving gate or barrier.

12. For a gate operator utilizing a contact sensor such as an edge sensor:

a. One or more contact sensors shall be located where the risk of entrapment or obstruction exists, such as at the leading edge, trailing edge and post mounted both inside and outside of a vehicular horizontal slide gate.

b. A hard wired contact sensor shall be located and its wiring arranged so the communication between the sensor and the gate operator is not subject to mechanical damage.

c. A wireless device such as one that transmits radio frequency (RF) signals to the gate operator for entrapment protection functions shall be located where the transmission of the signals are not obstructed or impeded by building structures, natural landscaping or similar obstruction. A wireless device shall function under the intended end-use conditions.

Role of Dealers, Installers, and Trained Gate System Technicians

• Ensure entire system being designed manufactured and installed meets all applicable standards and codes including UL 325 and ASTM F2200.

• Demonstrate the basic functions and safety features of the gate system to owners/end users/general contractors, including how to turn off power and how to operate the manual disconnect feature.

• Leave safety instructions, product literature, installation manual and maintenance manual with end user.

• Explain to the owners the importance of testing by a trained gate system technician that includes a routine re-testing of the entire system including the entrapment protection devices, and explain the need for the owners to insure that this testing is performed monthly.

Role of End Users/Home Owners

• Contact a trained gate systems technician to maintain and repair the gate system (End users should never attempt to repair the gate system).

• Retain and utilize the installation manual and maintenance and important safety instructions; see page 38.

• Routinely check all gate operator functions and gate movement.

• Discontinue use if safety systems operate improperly, the gate is damaged, or the gate is difficult to move. Contact trained gate systems technician to repair the gate system.

• Prominently display and maintain warning signs on both sides of the gate.

Gate Construction Information Vehicular gates should be installed in accordance with ASTM F2200: Standard Specification for Automated Vehicular Gate Construction. For a copy, contact ASTM directly at 610-832-9585 or www.astm.org.

1. General Requirements

1.1 Gates shall be constructed in accordance with the provisions given for the appropriate gate type listed, refer to ASTM F2200 for additional gate types.

1.2 Gates shall be designed, constructed and installed to not fall over more than 45 degrees from the vertical plane, when a gate is detached from the supporting hardware.

1.3 Gates shall have smooth bottom edges, with vertical bottom edged protrusions not exceeding 0.50 inches (12.7 mm) when other than the exceptions listed in ASTM F2200.

1.4 The minimum height for barbed tape shall not be less than 8 feet (2.44 m) above grade and for barbed wire shall not be less than 6 feet (1.83 m) above grade.

1.5 An existing gate latch shall be disabled when a manually

operated gate is retrofitted with a powered gate operator.

1.6 A gate latch shall not be installed on an automatically operated gate.

1.7 Protrusions shall not be permitted on any gate, refer to ASTM F2200 for Exceptions.

1.8 Gates shall be designed, constructed and installed such that their movement shall not be initiated by gravity when an automatic operator is disconnected, in accordance with the following.

1.8.1 Vehicular horizontal slide gate shall not result in continuous, unimpeded movement in either lineal direction of its travel.

1.9 For pedestrian access in the vicinity of an automated vehicular gate, a separate pedestrian access shall be provided or available. The pedestrian access shall be installed in a location such that a pedestrian shall not come in contact with a moving vehicular access gate during the entire path of travel of the vehicular gate. A pedestrian gate shall not be incorporated into an automated vehicular gate panel.

2. Specific Applications

2.1 Any non-automated gate that is to be automated shall be

upgraded to conform to the provisions of ASTM F2200.

2.2 This specification shall not apply to gates generally used for pedestrian access and to vehicular gates not to be automated.

2.3 When the gate operator requires replacement, the existing gate shall be upgraded to conform to the provisions of

ASTM F2200.

2.4 When the gate of an automated gate system requires

replacement, the new gate shall conform to the provisions of

ASTM F2200.

3. Vehicular Horizontal Slide Gates

3.1 The following provisions shall apply to Class I, Class II and Class III vehicular horizontal slide gates:

3.1.1 All weight bearing exposed rollers 8 feet (2.44 m), or less, above grade shall be guarded or covered.

3.1.2 All openings shall be designed, guarded, or screened from the bottom of the gate to the top of the gate or a minimum of 6 ft.

(1.83 m) above grade, whichever is less, to prevent a 2 1⁄4 in.

(57 mm) diameter sphere from passing through the openings anywhere in the gate, and in that portion of the adjacent fence that the gate covers in the open position. The gate panel shall include the entire section of the moving gate, including any back frame or counterbalance portion of the gate.

3.1.3 A gap, measured in the horizontal plane parallel to the roadway, between a fixed stationary object nearest the roadway, (such as a gate support post) and the gate frame when the gate is in either the fully open position or the fully closed position, shall not exceed 2-1/4 inches (57 mm). Exception: All other fixed stationary objects greater than 16 in. (406 mm) from the gate frame shall not be required to comply with this section.

3.1.4 Positive stops shall be required to limit travel to the designed fully open and fully closed positions. These stops shall be installed at either the top of the gate, or at the bottom of the gate where such stops shall horizontally or vertically project no more than is required to perform their intended function.

3.1.5 All gates shall be designed with sufficient lateral stability to assure that the gate will enter a receiver guide, refer to ASTM F2200 for panel types.

3.2 The following provisions shall apply to Class IV vehicular horizontal slide gates:

3.2.1 All weight bearing exposed rollers 8 feet (2.44 m), or less, above grade shall be guarded or covered.

3.2.2 Positive stops shall be required to limit travel to the designed fully open and fully closed positions. These stops shall be installed at either the top of the gate, or at the bottom of the gate where such stops shall horizontally or vertically project no more than is required to perform their intended function.

Carton Inventory NOT SHOWN: Documentation Packet, Chain #40 - 30 feet with #40 master link, Eye Bolt Kit

LiftMaster Monitored Retro-Reflective Photoelectric Sensor Model LMRRUL (1)

5 ft. Edge Sensor Kit Model S505AL (1)

Key (2)

Battery 12 Vdc 7AH (2)

Warning Signs (2) Installation Manual

CoverOperator

MONITORED ENTRAPMENT PROTECTION DEVICES

INTRODUCTION

Operator Specifications

Usage Classification Class I, II, III, and IV

Main AC Supply 120 Vac, 4 Amps (10 Amps including Accessory Outlets) OR 240 Vac, 2 Amps When Optional Transformer Kit Model 3PHCONV is installed in the field, operator is rated 208/240/480/575 VAC, 5.2/4.5/2.3/1.9 A, 60 Hz, 1 PH

System Operating Voltage 24 Vdc Transformer Run / Battery Backup

Accessory Power 24 Vdc, 1A max. for ON + SW (switched)

Solar Power Max 24 Vdc at 60 watts max.

Maximum Gate Weight 3,000 lbs. (1,360 kg)

Minimum Gate Travel Distance 4 feet (1.2 m)

Maximum Gate Travel Distance 75 feet (22.86 m)

Maximum Gate Travel Speed 1 ft./sec.

Maximum Daily Cycle Rate Continuous for line voltage, not continuous for solar

Maximum Duty Cycle Continuous

Operating Temperature Without Heater: -20°C to 60°C (-4°F to 140°F) With Optional Heater: -40°C to 60°C (-40°F to 140°F)

120VAC accessory power outlets 6 amps When the 3PHCONV kit is used, the outlets are only rated 1 Amp

External Entrapment Protection Device Inputs (non-contact and/or contact)

Main board - up to 2 close entrapment protection devices and 1 open entrapment protection device.

Expansion board - up to 3 entrapment protection devices configurable to either the close or open direction and up to 8 edge sensors when using the wireless edge sensor kit model LMWEKITU and LMWETXU.

25.1" (50.8 cm)

17.51" (44.5 cm)

16.77 [42.6 cm]

10.31" (26.2 cm)

10.4" (26.4 cm)

2.52" (6.4 cm)

Site Preparation Check the national and local building codes BEFORE installation. Refer also to the Site Planning Safety Checklist in the Appendix.

Conduit and Concrete Pad Trench and install conduit. Before trenching, contact underground utility locating companies. Conduit must be UL approved for low and high voltage. Consider the operator placement BEFORE installing the pad or post.

Concrete Pads

Safety Entrapment protection devices are required to protect against any entrapment or safety conditions encountered in your gate application. Install a warning sign (two provided) on the inside and outside of the property, where easily visible.

Warning Sign

Gate Gate must be constructed and installed according to ASTM F2200 standards (refer to page 4). Gate must fit specifications of operator (refer to specifications).

SAFETY CATCH ROLLERS

Install catch rollers with safety covers on the side of a post or wall with a minimal distance of half an inch between the rollers and gate

DO NOT use a gate catch post.

Because the coasting distance may vary due to changes in temperature, it is NOT recommended to install a catch post in front of the gate's path.

To do so will cause the gate to hit the post in certain instances.

Additional Accessories The vehicle loops allow the gate to stay open when vehicles are obstructing the gate path. Suggested for vehicles 14 feet (4.27 m) or longer. Vehicle loops are not required but are recommended. Before installing your Access Control Device(s) be sure to complete a site survey and determine the best device for your site needs.

Outside Property

Vehicle Loops

Access Control Device

• To AVOID damaging gas, power or other underground utility lines, contact underground utility locating companies BEFORE digging more than 18 inches (46 cm) deep.

• ALWAYS wear protective gloves and eye protection when changing the battery or working around the battery compartment.

Types of Installations

Standard Installation

Gate Rail Stop

Operator

(Inside Property)

Gate Rail Stop

Rear Installation

(Inside Property)

Gate Rail Stop

Operator

Gate Rail Stop

INSTALLATION

Step 1 Determine Location for Operator Check the national and local building codes before installation.

Standard Installation

1. The gate operator should be installed near the front roller of the gate. Lay out the concrete pad.

2. Install the electrical conduit.

3. Pour a concrete pad (reinforced concrete is required).

(Gate)

Front gate roller

(conduit)

Below the frost line. Check all national and local codes.

6" (15.2 cm) Above Ground

1/2" (1.8 cm) 1"-2" (2.5-5.1 cm)

(Pad)

(conduit location)

Rear Installation

1. The gate operator should be installed near the back of the gate in the OPEN position. Lay out the concrete pad.

2. Install the electrical conduit.

3. Pour a concrete pad (reinforced concrete is required).

(conduit)

Back of gate

(Gate in open position)

Below the frost line. Check all national and local codes.

6" (15.2 cm) Above Ground

1/2" (1.8 cm) 1"-2" (2.5-5.1 cm)

(Pad)

(conduit location)

Step 2 Install the Operator Attach the operator to the concrete pad with appropriate fasteners. The gate operator should be installed near the front roller of the gate or near the back of the gate (in the OPEN position). The space between the gate and the output sprocket must be a minimum of 4 inches (10.2 cm). NOTE: An alternative to a concrete pad is to post mount the operator (refer to Accessories).

Post Mount

4 Concrete Anchors 1/2" x 3 1/2"

4" (10.2 cm)

(chain location)

Post Moun

Step 3 Attach the Chain Standard Installation DO NOT run the operator until instructed.

1. Manually open the gate and line up the front bracket so the chain will be level with the idler pulley and parallel to the ground. Weld the front bracket in this position.

2. Manually close the gate and line up the rear bracket so the chain will be level with the idler pulley and parallel to the ground. Weld the rear bracket in this position.

3. Route the chain through the operator.

4. Connect the chain to the brackets using the eye bolt hardware. Chain should not be too tight or have excessive slack.

5. Remove the pin from the vent plug on the gear box.

NOTE: The chain should have no more than 1 inch (2.5 cm) of sag for every 10 feet (3 m) of chain length.

Idler Pulley

Rear Bracket Front Bracket

Pin

Vent Plug

Rear Installation DO NOT run the operator until instructed.

NOTE: This installation will require two extra idler pulleys. Make sure all exposed pinch points are guarded. Refer to Gate Construction Information on page 5.

1. Move the back pulley to the bottom hole in the operator.

2. Manually close the gate and align the bottom bracket so the chain will be level with the bottom idler pulley and parallel to the ground. Weld the bottom bracket in this position.

3. Align the top bracket so the chain will be level with the top idler pulley and parallel to the ground. Weld the upper bracket in this position.

4. Route the chain through the operator.

5. Connect the chain to the brackets using the eye bolt hardware. Chain should not be too tight or have excessive slack.

6. Remove the pin from the vent plug on the gear box.

NOTE: The chain should have no more than 1 inch (2.5 cm) of sag for every 10 feet (3 m) of chain length.

Idler Pulley MUST have safety cover.

Pin

Vent Plug

To prevent SERIOUS INJURY or DEATH from a moving gate:

• ALL gate operator systems REQUIRE two independent entrapment protection systems for each entrapment zone.

• Entrapment protection devices MUST be installed to protect anyone who may come near a moving gate.

• Entrapment protection devices MUST be located to protect in BOTH the open and close gate cycles.

• Locate entrapment protection devices to protect between moving gate and RIGID objects, such as posts, walls, pillars, columns, or operator itself.

Step 4 Install Entrapment Protection Definitions

ENTRAPMENT:

The condition when a person is caught or held in a position that increases the risk of injury.

SLIDE GATE ENTRAPMENT ZONE:

An entrapment zone exists if at any point during travel, the gap between the gate and any opposing fixed edge or surface such as posts, walls, pillars, columns or operator itself, is less than 16" (406 mm) in a location up to 6 ft. (1.8 m) above grade.

Install entrapment protection devices according to the UL 325 Entrapment Protection Requirements section, see page 3. Use the Site Planning Safety Checklist in the appendix, to identify entrapment zones that will result from the installation. See Accessories for approved entrapment protection devices.

Requirements

1. Install entrapment protection devices for ALL entrapment zones. This operator has an inherent entrapment protection device built-in. The installer MUST provide one additional entrapment protection device for each entrapment zone.

2. The operator will NOT run unless aminimum of two external devices are connected; one in the open direction and one in the closed direction.

3. Test ALL entrapment protection devices AFTER installing the operator, refer to the manual provided with your entrapment protection device. Test the inherent entrapment protection by following the Obstruction Test instructions page 25.

SeeWire Entrapment Protection Devices page 16.

Illustration is for example only; your site may have additional entrapment zones which MUST be protected.

Secure Side

Public Side

Gap between vertical bars MUST be less than 2-1/4" (57 mm)

Interior posts, non-pinch rollers (2x)

Place warning signs on both sides of the gate in clear view

Take a photograph of the complete installation site for your records

Any gap larger than 2-1/4" (57 mm) between gate and fixed objects MUST be protected.

Install edge sensors where gap between post and gate creates an entrapment zone.

Pedestrian gate located near the slide gate.

Make sure a separate pedestrian entrance is available and the path is clearly designated.

6' (1.8 m) minimum

Photoelectric sensor (close direction)

Photoelectric sensor (close direction)

Photoelectric sensor (open direction)

Photoelectric sensor (open direction)

Left hand gate opening

Edge sensor Edge sensor

Edge sensor

Earth ground

Illustrations provided by DASMA Gate Systems Safety Guide

Wire Entrapment Protection Devices There are three options for wiring external entrapment protection devices depending on the specific device and how the device will function. Refer to the manual included with your entrapment protection device for more information. These entrapment protection device inputs are for monitored devices, which include pulsed photoelectric sensors, resistive edge sensors, and pulsed edge sensors. Only one monitored entrapment protection device may be wired to each input. Additional monitored entrapment protection devices may be wired to the expansion board.

NOTE: Board inputs for entrapment protection devices are yellow.

Control Board

CLOSES EYES/INTERRUPT

(2 Terminals) The CLOSE EYES/INTERRUPT input is for photoelectric sensor entrapment protection for the close direction. When an obstruction is sensed during gate closing the gate will open to the full open position and resets the Timer-to-Close. This input will be disregarded during gate opening.

CLOSE EDGE

(2 Terminals) The CLOSE EDGE input is for edge sensor entrapment protection for the close direction. When an obstruction is sensed during gate closing the gate will reverse to the full open position, disengaging the Timer-to-Close. This input will be disregarded during gate opening.

OPEN EYES/EDGE

(2 Terminals) The OPEN EYES/EDGE input is for photoelectric sensor or edge sensor entrapment protection for the open direction. When an obstruction is sensed during gate opening the gate will reverse for 4 seconds then stop. This input will be disregarded during gate closing.

Close Photoelectric Sensors

Open Photoelectric Sensors OR Open Edge

Close Edge

Expansion Board EYE ONLY and COM Open or Close Direction Photoelectric Sensors, the functionality is based on the switch settings (located next to the terminals) Switch set to CLOSE: gate reverses fully when an obstruction is sensed Switch set to OPEN: gate reverses 4 seconds when an obstruction is sensed EYE/EDGE and COM Open or Close Direction Photoelectric Sensors or Edge Sensor, the functionality is based on the switch settings (located next to the terminals) Switch set to CLOSE: gate reverses fully when an obstruction is sensed Switch set to OPEN: gate reverses 4 seconds when an obstruction is sensed

WIRELESS EDGE

Connection for wireless edge receiver. NOTE: ONLY one wireless edge receiver may be connected to an operator. Up to 4 wireless edge transmitters LMWETXU may be programmed to the receiver.

Photoelectric Sensors

Wireless Edge Receiver

Photoelectric Sensors

OR

Edge Sensor

Step 5 Earth Ground Rod Use the proper earth ground rod for your local area. The ground wire must be a single, whole piece of wire. Never splice two wires for the ground wire. If you should cut the ground wire too short, break it, or destroy its integrity, replace it with a single wire length.

1. Install the earth ground rod within 3 feet (.9 m) of the operator.

2. Run wire from the earth ground rod to the operator.

NOTE: If the operator is not grounded properly the range of the remote controls will be reduced and the operator will be more susceptible to lightning and surge damage.

To operator

Check national and local codes for proper depth

Step 6 Power Wiring

To reduce the risk of SEVERE INJURY or DEATH:

• ANY maintenance to the operator or in the area near the operator MUST NOT be performed until disconnecting the electrical power (AC or solar and battery) and locking-out the power via the operator power switch. Upon completion of maintenance the area MUST be cleared and secured, at that time the unit may be returned to service.

• Disconnect power at the fuse box BEFORE proceeding. Operator MUST be properly grounded and connected in accordance with national and local electrical codes. NOTE: The operator should be on a separate fused line of adequate capacity.

• ALL electrical connections MUST be made by a qualified individual.

• DO NOT install ANY wiring or attempt to run the operator without consulting the wiring diagram.

• ALL power wiring should be on a dedicated circuit and well protected.

The location of the power disconnect should be visible and clearly labeled.

• ALL power and control wiring MUST be run in separate conduit.

The operator can be wired for either 120 Vac or 240 Vac or a solar panel (not provided). Follow the directions according to your application. An optional Transformer Kit (Model 3PHCONV) can be used to change the input voltage (208/240/480/575 Vac) to an output voltage of 120 Vac (refer to Accessories). For dual gate applications, power will have to be connected to each operator. Main power supply and control wiring MUST be run in separate conduits.

SOLAR APPLICATIONS: For solar applications see page 48 in the Solar Panels section. Follow the directions according to your application.

NOTE: If using an external receiver use shielded wire for the connections and mount the receiver away from the operator to avoid interference from the operator.

MAXIMUMWIRE LENGTH

AMERICAN

WIRE

GAUGE

(AWG)

STANDARD OPERATOR OPERATOR + ACCESSORIES POWERED BY TRANSFORMER KIT

accessory power outlets rated at 1 amp when the 3PHCONV kit is used

120 VAC, 10A

(includes fully loaded outlets)

120 VAC, 4A 240 VAC, 2A 208 VAC, 4.8A 240 VAC, 4.2A 480 VAC, 2.1A 575 VAC, 1.7A

14 75 150 600 200 450 1,700 2,500

12 125 225 900 300 700 2,800 4,000

10 200 360 1,500 500 1,200 4,400 6,400

8 300 600 2,300 800 1,800 7,000 10,000

6 500 900 3,600 1,200 2,800 11,000 16,000

4 800 1,500 5,800 2,000 4,500 18,000 25,000

Chart assumes: copper wire, 65°C, 5% drop

All control wiring used to connect external devices to Class 2 circuits of the operator must be (QPTZ) Power-Limited Circuit Cables, Type CL2, CL2P, CL2R, or CL2X or other cable with equivalent or better electrical, mechanical, and flammability ratings.

1. Turn off the AC power from the main power source circuit breaker.

2. Run the AC power wires to the operator.

3. Make sure the operator AC switch is in the OFF position, see page 18.

4. Remove the junction box cover from the electrical box by loosening the screws and sliding the cover to the side.

5. 120 Vac: Factory default is 120 Vac. Skip to 5.

240 Vac: Unplug the power wiring connector from the 120 Vac socket (factory default location) and plug it into the 240 Vac socket.

NOTE: The accessory outlets are disabled and cannot be used with the 240 Vac option.

6. Connect the incoming green wire to the earth ground nut.

7. Connect the white wire to NEUTRAL using a wire nut.

8. Connect the black wire to HOT using a wire nut.

9. Replace the junction box cover. Ensure the wires are not pinched.

Power Wiring Connector

EMI Board

Incoming Power

White

Black

Green ground wire

Plug In Transformer Power Wire plug in transformer power as shown.

Plug in transformer

Control Board

Set switch to

WALL XFMR

AC Power Switch The AC switch on the operator turns the incoming 120/240 Vac power ON or OFF. The AC switch ONLY turns off AC power to the control board and DOES NOT turn off battery power.

Battery Switch The battery switch turns the battery power on or off.

AC Power Switch Battery Switch

Step 7 Connect Batteries 7AH Batteries The batteries are charged in the circuit by the integrated transformer.

1. Turn the AC power switch to OFF.

2. Turn the battery switch OFF .

3. Connect a jumper between the positive(+) terminal of the battery to the negative terminal(-) of the other battery.

4. Connect the red battery wire from the operator to the positive(+) terminal of the battery.

5. Connect the black battery wire from the operator to the negative (-) terminal of the battery.

6. Turn the battery switch ON .

7. Turn the AC power switch to ON to restore AC power.

Red Wire Black WireJumper

Battery Wiring

33AH Batteries The batteries are charged in the circuit by the integrated transformer. The 33AH application requires battery harness K41-0102-000, see Accessories.

1. Turn the AC power switch to OFF.

2. Turn the battery switch OFF.

3. Connect a jumper between the positive(+) terminal of the battery to the negative terminal(-) of the other battery.

4. Connect the (+) terminal of the battery to the red battery wire from the operator using the RED harness kit wire .

5. Connect the (-) terminal of the battery to the black battery wire from the operator using the BLACK harness kit wire.

6. Turn the battery switch ON .

7. Turn the AC power switch to ON to restore AC power.

33AH batteries are NOT compatible if transformer kit model 3PHCONV is installed.

Battery Wiring

Red Wire Black Wire

Jumper

Red wire from battery harness

33AH, HD Gates K41-0102-000

Black wire from battery harness 33AH, HD Gates K41-0102-000

Step 8 Dual Gate setup There are two options for dual gate communication: wired or wireless. Follow the directions according to your application. Do not use wired and wireless communication simultaneously. Use only the same operator models in a dual gate setup. Wired dual gate applications will have a longer battery standby time than wireless applications.

Wireless setup To activate the wireless feature:

1. Choose an operator to be the network primary operator. Program all wireless accessories to the primary operator except for any wireless entrapment protection devices required for the second operator. NOTE:We recommend that all accessories, except entrapment protection devices, and board configurations are set on the primary operator.

2. Press and release the LEARN button on the primary operator. The green XMITTER LED will light. NOTE: The operator will time out of programming mode after 180 seconds.

3. Press and release the LEARN button again on the primary operator. The yellow NETWORK LED will light.

4. Press and release the OPEN test button to assign this operator as network primary.

5. Press and release the LEARN button on the second operator. The green XMITTER LED will light.

6. Press and release the LEARN button again on the second operator. The yellow NETWORK LED will light.

7. Press and release the CLOSE test button to assign this operator as network second.

Both operators will beep and the yellow NETWORK LEDs will turn off indicating programming is successful.

To deactivate the wireless feature:

1. Press and release the LEARN button on either operator. The green XMITTER LED will light.

2. Press and release the LEARN button again on the same operator. The yellow NETWORK LED will light.

3. Press and hold the LEARN button for 5 seconds. The yellow NETWORK LED will blink (operator will beep) then turn off indicating successful deactivation.

4. Press and release SET OPEN and SET CLOSE buttons simultaneously. The yellow SET OPEN and SET CLOSE LEDs will light.

5. Press and release SET OPEN and SET CLOSE buttons simultaneously again. Both yellow LEDs will turn off and entrapment protection devices will be relearned.

6. Repeat the steps for the other operator.

Outside

Property

Inside

Property

Wired setup Use only the same operator models in a dual gate setup. Before digging, contact local underground utility locating companies. Use PVC conduit to prevent damage to cables.

1. Disconnect ALL power to the operator and turn OFF the battery and

AC power switches.

2. Trench across driveway to bury the shielded twisted pair cable.

3. Connect the wires from the shielded twisted pair cable to the Com Link terminals on the primary gate operator control board. NOTE:We recommend that all accessories, except entrapment protection devices, and board configurations are set on the primary operator.

4. Route the shielded twisted pair cable to the secondary gate operator's control board.

5. Connect the wires from the shielded twisted pair cable to the Com Link terminals on the secondary control board (Com Link A to Com Link A and Com Link B to Com Link B). Ground the shield of the cable to the chassis ground of one operator.

6. Connect ALL power to the operator and turn ON the battery and AC power switches.

DUAL GATE WIRE TYPE (SHIELDED TWISTED PAIR CABLE)

22AWG up to 200 feet (61 m) 18AWG - 200-1000 feet (61-305 m)

Wire must be rated at 30 Volt minimum

Com Link Data A

Com Link Data B

Com Link Data A

Com Link Data B

Bipart delay/synchronized close The BIPART DELAY switch is used only with dual gate applications and serves two functions:

• BIPART DELAY

Not applicable for slide gate applications.

• SYNCHRONIZED CLOSE

To synchronize the closing of the gates, set the BIPART DELAY switch to ON for both operators.

Step 9 Install the cover Before installing the cover, follow the instructions in the Adjustment section to adjust the limits, speed, and force.

1. Slide the cover over the operator.

2. Align the holes in the cover with the threaded holes in the operator's chassis and secure the cover with the provided screws.

Screw

Screw

Step 10 Install Warning Signs Installers MUST install the UL required warning signs. The signs MUST be installed in plain view on both sides of each gate installed. Use the fastening holes in each corner to permanently secure the sign.

Place warning signs on both sides of the gate in clear view

The basic installation is complete.

Limit, Speed, and Force Adjustment

To reduce the risk of SEVERE INJURY or DEATH:

• Without a properly installed safety reversal system, persons (particularly small children) could be SERIOUSLY INJURED or KILLED by a moving gate.

• Too much force on gate will interfere with proper operation of safety reversal system.

• NEVER increase force beyond minimum amount required to move gate.

• NEVER use force adjustments to compensate for a binding or sticking gate.

• If one control (force, speed or travel limits) is adjusted, the other controls may also need adjustment.

• After ANY adjustments are made, the safety reversal system MUST be tested. Gate MUST reverse on contact with an object.

• Faster gate speed increases risk to pedestrians. Use minimum speed necessary to move gate.

Introduction Your operator is designed with electronic controls to make travel limit and force adjustments easy. The adjustments allow you to program where the gate will stop in the open and close position. The electronic controls sense the amount of force required to open and close the gate.

The force is adjusted automatically when you program the limits but should be fine tuned using the REVERSAL FORCE dial on the control board (refer to Fine Tune the Force section) to compensate for environmental changes. The limit setup LEDs (located next to the SET OPEN and SET CLOSE buttons) indicate the status of the limits, refer to the table to the right.

The limits can be set using the control board (below) or a remote control (refer to Limit Setup with a Remote Control in the Appendix). Setting the limits with a remote control requires a 3-button remote control programmed to OPEN, CLOSE, and STOP.

NOTE: The TEST buttons on the control board will not work until the limits have been set and the required entrapment protection devices are installed.

LIMIT SETUP LEDS

SET

OPEN

LED

SET

CLOSE

LED

OPERATOR

MODE

EXPLANATION

OFF OFF NORMAL MODE Limits are set

BLINKING BLINKING LIMIT SETTING

MODE

Limits are not set

BLINKING ON LIMIT SETTING

MODE

Open limit is not set

ON BLINKING LIMIT SETTING

MODE

Close limit is not set

ON ON LIMIT SETTING

MODE

Limits are set

Set the Initial Limits, Speed, and Force For dual gate applications the limits will have to be set for each operator. The gate MUST be attached to the operator before setting the limits and force.

For slide gate applications the open limit and closed limit MUST be set at least four feet apart.

1. Press and release the SET OPEN and SET CLOSE buttons simultaneously to enter limit setting mode.

2. Press and hold one of the MOVE GATE buttons to move the gate to the open or close limit.

3. Press and release the SET CLOSE or SET OPEN button depending on which limit is being set.

4. Press and hold one of the MOVE GATE button to move the gate to the other limit.

5. Press and release the SET CLOSE or SET OPEN button depending on which limit is being set.

6. Set the speed dial to the desired setting, see page 24.

0.5 ft/sec. min - 1 ft./sec. max.

7. Cycle the gate open and close. This automatically sets the force.

When limits are set properly the operator will automatically exit limit setting mode.

ADJUSTMENT

Speed Control The SPEED CONTROL dial controls the speed of the operator. The dial is preset to minimum from the factory. Set the speed as low as possible for the intended application.

Gate operating speed: 0.5 ft./sec. - 1 ft./sec.

For dual gate setup, set the SPEED CONTROL dial on each operator to the same setting or make sure the gate that travels further is set faster than the other operator for the smoothest operation.

After any speed adjustment:

1. Cycle the gate open and close to automatically relearn the forces.

2. Perform the Obstruction Test, see page 25.

Fine Tune the Force Once the initial limits have been set, the REVERSAL FORCE DIAL on the control board is used for fine tuning the force where wind or environmental changes may affect the gate travel. The REVERSAL FORCE DIAL is set to minimum at the factory.

Based on the length and weight of the gate it may be necessary to make additional force adjustments. The force setting should be high enough that the gate will not reverse by itself nor cause nuisance interruptions, but low enough to prevent serious injury to a person. The force setting is the same for both the open and close gate directions.

1. Open and close the gate with the TEST BUTTONS.

2. If the gate stops or reverses before reaching the fully open or closed position, increase the force by turning the force control slightly clockwise.

3. Perform the “Obstruction Test” after every limit, speed, and force setting adjustment see page 25.

Settings 1-3: Fixed force settings (gate will not adjust due to gate wear or temperature changes).

Settings 4-10: Automatically increase the force due to gate wear or temperature changes.

Adjust the Limits After both limits are set and the operator is ready to run, one limit can be adjusted independently from the other by following steps 1-3 of the Initial Limit and Force Adjustment section.

After any limit adjustment:

1. Cycle the gate open and close to automatically relearn the forces.

2. Perform the Obstruction Test, see page 25.

Obstruction Test The operator is equipped with an inherent (built in to the operator) obstruction sensing device. If the gate encounters an obstruction during motion, the operator will reverse direction of the gate and then stop. The following procedure will test ONLY the inherent (built in to the operator) obstruction sensing device:

1. Open and close the gate with the TEST BUTTONS, ensuring that the gate is stopping at the proper open and close limit positions.

2. Either place an object between the open gate and the fixed closed catch post or obstruct the gate by hand. Make sure that any external entrapment protection devices, such as an edge or photoelectric sensor will NOT be activated by the object or by hand.

3. Run the gate in the close direction. The gate should stop and reverse upon contact with the object or hand. If the gate does not reverse, reduce the force setting by turning the force control slightly counter-clockwise. The gate should have enough force to reach both the open and close limits, but MUST reverse after contact with an object or hand.

4. Repeat the test for the open direction.

Test the operator after any adjustments are made.

OR

OR

Remote Controls (Not Provided) A total of 50 Security+ 2.0® remote controls or KPW250 keypads and 2 keyless entries (1 PIN for each keyless entry) can be programmed to the operator. When programming a third keyless entry to the operator, the first keyless entry will be erased to allow the third keyless entry to be programmed. When the operator’s memory is full it will exit the programming mode and the remote control will not be programmed. The memory will need to be erased before programming any additional remote controls. NOTE: If installing an 86LM to extend the range of the remote controls DO NOT straighten the antenna.

There are 3 different options for programming the remote control depending on how you would like the remote control to function. Choose a programming option:

OPTION DESCRIPTION PROGRAMMING STEPS

Single button as OPEN only

Program a single button on the remote control for open only. The Timer-to-Close can be set to close the gate.

1. Press and release the LEARN button (operator will beep and green XMITTER LED will light). NOTE: The operator will time out of programming mode after 30 seconds.

2. Press the OPEN button.

3. Press the remote control button that you would like to program.

Single button (SBC) as OPEN, CLOSE, and STOP

Program one remote control button as an open, close, and stop.

1. Press and release the LEARN button (operator will beep and green XMITTER LED will light). NOTE: The operator will time out of programming mode after 30 seconds.

2. Press the remote control button that you would like to program.

Three separate buttons as OPEN, CLOSE, and STOP

Program each remote control button as an open, close, and stop.

1. Press and release the LEARN button (operator will beep and green XMITTER LED will light). NOTE: The operator will time out of programming mode after 30 seconds.

2. Press the OPEN, CLOSE, or STOP button, depending on the desired function.

3. Press the remote control button that you would like to program.

The operator will automatically exit learn mode (operator will beep and green XMITTER LED will go out) if programming is successful. To program additional Security+ 2.0® remote controls or remote control buttons, repeat the programming steps above.

Entering programming mode using external reset switch or 3-button control station:

1. Make sure gate/door is closed.

2. Give the operator an OPEN command.

3. To put the operator into high band programming mode, give the operator an OPEN command. Within 30 seconds, when the gate is at the open limit, toggle the reset switch between RESET and NORMAL OPERATION three times or push the button on the control station three times. NOTE: The operator will time out of programming mode after 30 seconds.

NOTICE: This device complies with Part 15 of the FCC rules and Industry Canada’s license-exempt RSSs. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

This device must be installed to ensure a minimum 20 cm (8 in.) distance is maintained between users/bystanders and device.

This device has been tested and found to comply with…