This document is an installation manual for the CP-4 Automatic Gate Opener, a vehicle detection sensor designed for gate access control systems. The manual provides comprehensive technical specifications and installation instructions, including detailed guidance on cable routing, conduit installation, sensitivity adjustment, and positioning. Key technical details include power requirements of 8-24 VAC or 8-30 VDC, a standby current of 30-70 microamps, an operating temperature range of -25°F to +140°F, and a 5-year warranty covering material and workmanship defects.
The manual outlines specific installation considerations such as recommended placement distances from utilities (minimum 6-10 feet from buried power lines, 10 feet from gas lines, 20 feet from transformers), vehicle detection speed requirements (minimum 5 MPH), and burial depth of 3-5 inches below surface. The device features adjustable sensitivity levels (high, medium, low) and compatibility with various gate operators. Contact information for technical support, returns, and company details are provided, with Cartell located in Shippensburg, PA, offering support through multiple phone options and email channels.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 1240LU25Q0072 Shenango Helibase fencing.pdf | ||
| Gooseneck_Padmount_Dimensions.pdf | ||
| AK-11_Keypad.pdf | ||
| SOW SectionC_FY25ShenagoFenceInstall_7-22.docx | DOCX document | |
| GateOperator_hdsl24ul_Manual.pdf | ||
| Experience Questionnaire.pdf | ||
| Wage Determinations mt75.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
INSTALLATION INSTRUCTIONS FOR
CP-4 AUTOMATIC GATE OPENER*
1. SERIAL NUMBER
There is a barcode serial number on the bottom of “puck” and on the product box. When calling to talk about your product, please have this number handy.
PRODUCT
CODE
YEAR
MADE
SERIAL
NUMBER
2. TRENCH PIPE & CABLE
NOTE:
Warranty void if cable not run in conduit
3. CONDUIT & SLIP JOINT
After pulling cable through plastic conduit, insert conduit inside slip joint on “puck.”
DO NOT GLUE (to un-install later, if needed).
NOTE: IN MOST CASES DO NOT
ADJUST SENSITIVITY OR REMOVE LID.
5. TEST SENSITIVITY
4. CONNECT TO GATE
RED
BLACK
POWER +
WHITE COMMON
YELLOW EXIT N.C.
BLUE EXIT N.O.
POWER ─
DUAL EXIT TERMINAL SINGLE EXIT TERMINAL
RED POWER +
BLACK
WHITE
BLUE FREE EXIT
or OPEN
TERMINAL
GND or COM
CP-4 works with all gate operators―powered or solar, single or dual free exit terminals.
VOLTAGE CURRENT
8-24 VAC
8-30 VDC
Standby: 30-70 µA Alarm: 40-60 mA
SENSITIVITY ADJUSTMENT
HIGH (Default) Detects vehicle going 5 MPH 12-14’ away 1 & 2 in OFF position
MEDIUM
Detects vehicle going 5 MPH 6-8’ away 1 ON & 2 OFF position
LOW
Detects vehicle going 5 MPH 2-3’ away 1 & 2 in ON position 1 2
ON
1 2
ON
1 2
ON
6. BURY CONDUIT & “PUCK”
Test unit with gate by swinging steel over puck (or driving vehicle by). If it opens the gate correctly, finish installation by burying conduit and puck 3-5" below surface.
80' - 100'
12' Note: Dip switch color may vary
• Trench 1/2" PVC pipe to placement of CP-4
• Smooth out entire length of cable before pulling thru PVC pipe
• Gently pull cable thru PVC pipe (may need wire lubricant)
*Patent Pending
Technical Specifications
Power Required 8–24 VAC or 8–30 VDC
Stand-By Current 30–70 Microamps (μA)
Alarm Current 30–40 Milliamps (mA)
Relay Time 2–3 seconds
Relay Contacts SPDT, floating, N.O. or
N.C. (Form C)
Relay Contact Rating 1 amp/24 VDC
(1 mA at 5 VDC min. load)
Enclosure Rating IP67
Strength Rating
9.53 ton-force
8646 kgf
Temperature Range -25° F. – +140° F.
-32° C. – 60° C.
Dimensions 4.5 in. dia. x 2.5 in. high
Weight 5 lbs. with 100 ft. cable
The CP-4 complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
OTHER INSTRUCTIONS
• CP-4 may be installed above ground by screwing “puck” directly to an immovable post or building
• If installed above ground, use conduit to mechanically protect cable (animals will eat)
• Car should be going at least 5 MPH at sensor to be detected
Install CP-4 at least:
• 6-10 feet away from buried power, telephone, or invisible dog fence
| • | 10 feet away from natural gas lines |
| • | 20 feet away from power pole with a |
transformer
| • | 100 feet back from railroad traffic |
| • | 200 feet away from high power substation |
power lines
• 80-100 feet back from gate operator
RETURNING MERCHANDISE
CONSUMER: Contact your installer
INSTALLER: CALL BEFORE DIGGING UP
Call (717) 532-0033, option 1 to troubleshoot and receive a Return Merchandise Authorization (R.M.A.) number. Write R.M.A. number on return shipping box and any correspondence included with defective product.
DISTRIBUTOR: Send installers directly to Cartell, using 717-532-0033, option 1 as phone number.
5 YEAR WARRANTY
All Cartell products are warranted against defects in material and workmanship for five years.
This warranty does not cover defects caused by, but not limited to: acts of God, improper installation, abuse, fire damage, electrical surges, integrated system failures, improper lid/gasket installation, and damage to cable (if applicable) caused by slicing, pulling, tangling, improper splicing or not running in non-metalic conduit.
WARRANTY
W
A R
RANTY WARRA
N
TY
Y
E A R
CONTACT INFORMATION
TECH SUPPORT 717-532-0033, option 1
RMA’s 717-532-0033, option 1
SHIPPING 717-532-0033, option 2
ACCOUNTING 717-532-0033, option 3
INSIDE SALES 717-532-0033, option 4
EMAIL info@cartell.com
ORDERING
(Distributors only) orders@cartell.com
ADDRESS 510 West King Street Shippensburg, PA 17257
WEBSITE www.cartell.com
Copyright © 2020 by Cartell
| INSTALLATION INSTRUCTIONS FOR CP-4 AUTOMATIC GATE OPENER |
| 1. SERIAL NUMBER |
| 2. TRENCH PIPE & CABLE |
| 3. CONDUIT & SLIP JOINT |
| 4. CONNECT TO GATE |
| 5. TEST SENSITIVITY |
| 6. BURY CONDUIT & “PUCK” |
| OTHER INSTRUCTIONS |
| Technical Specifications |
| RETURNING MERCHANDISE |
| 5 YEAR WARRANTY |
| CONTACT INFORMATION |
File details come from the government source that posted it. Updated .