The document is a comprehensive set of engineering plans and technical specifications for the Riverside Dock and Pier Replacement Project for the City of Fort Myers, Florida. The project involves replacing an existing dock and pier along the Caloosahatchee River, with detailed plans for a 291-foot main access dock, a 20x20 foot observation pier, a 6x24 foot floating paddlecraft launch, and associated infrastructure including solar lighting, fire suppression standpipes, handrails, and sidewalk improvements. The project will be constructed in the existing footprint of the current structures, with specific design considerations for marine environmental conditions, including pile driving, decking materials, and protective wrapping.
The technical specifications outline precise requirements for materials, including Southern Yellow Pine pilings treated with Chromium Copper Arsenate, Micro-Mesh decking, and FiberGrate components. The project includes five solar-powered LED lighting assemblies, fire protection connections positioned at strategic intervals, and restoration of surrounding walkways. The design accounts for local environmental factors such as mean high water (MHW) and mean low water (MLW) levels, with wind resistance specifications up to 160 mph. While no specific budget is provided in the documents, the detailed engineering plans suggest a comprehensive marine infrastructure renewal project aimed at improving public waterfront access and safety.
View the file
Other files
Show all 23
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
This item has been digitally signed and sealed by Hans J.M. Wilson on the date adjacent to the seal.
Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies.
SECTION: 7
TOWNSHIP: 44 S
RANGE: 25 E
PREPARED FOR
RIVERSIDE DOCK AND PIER
REPLACEMENT
FORT MYERS, FLORIDA 33916
PROJECT LOCATION MAP
1" = 3000'
PREPARED BY:
THIS IS TO CERTIFY THAT THESE PLANS AND THE ASSOCIATED
CONSTRUCTION PROJECT ARE IN SUBSTANTIAL COMPLIANCE
WITH THE CITY OF FORT MYERS GROWTH MANAGEMENT CODE
WITH THE EXCEPTION OF THE FOLLOWING DEVIATIONS WHICH
HAVE BEEN APPROVED BY THE DIRECTOR OF PUBLIC WORKS.
Deviations: No deviations required for this project
Florida P.E. #: 39680Hans J.M. Wilson, P.E.
Date
WATER & SEWER
CITY OF FORT MYERS PUBLIC WORKS DEPARTMENT
Fort Myers, FL 33916
(239) 321-8100
CENTURY LINK - TELEPHONE-FLORIDA
P. O. Box 370, Fort Myers, FL 33901
(239) 337-9460
LIST OF UTILITY SERVICE AREAS:
COMCAST CABLE
8061 Dani Drive, Suite 120, Fort Myers FL 33966
(239) 574-2020
TECO / PEOPLES GAS
5901 Enterprise Parkway, Fort Myers, FL 33905
(239) 690-5507
FLORIDA POWER AND LIGHT
1833 Lee Street, Fort Myers, FL 33901
(866) 263-9185
FORT MYERS CITY COUNCIL
2200 SECOND STREET
FORT MYERS, FLORIDA 33902
TELEPHONE (239) 321-7445 FAX (239) 344-5943
Engineering Division
NICOLE MONAHAN, P.E - City Engineer
DEPARTMENT OF PUBLIC WORKS
PETER BIENIEK - Public Works Director
MAYOR - KEVIN B. ANDERSON
WARD 1 - TERESA WATKINS BROWN
WARD 2 - JOHNNY W. STREETS, JR.
WARD 3 - TEROLYN WATESON
WARD 4 - LISTON BOCHETTE III
WARD 5 - FRED BURSON
WARD 6 - DARLA BONK
FORT MYERS CITY MANAGER
MARTY LAWING
INDEX OF DRAWING
Sheet 1 Cover
Sheet 2 Overall Site Aerial
Sheet 3 Detail A - Pier Replacement
Sheet 4 Detail B - Dock Replacement
Sheet 5 Detail C - Paddle Craft Launch
Sheet 6 Cross Section A-A
Sheet 7 Covered Deck Details
Sheet 8 Cross Section B-B
Sheet 9 Cross Sections C-C & D-D
Sheet 10 Cross Section E-E
Sheet 11 Lighting Assembly
Sheet 12 Technical Specifications
Sheet 13 Fire Suppression
CITY OF FORT MYERS
P.O. BOX 2217
FORT MYERS, FLORIDA 33902
PROPERTY OWNER:
CITY OF FORT MYERS
P.O. BOX 2217
FORT MYERS, FLORIDA 33902
PROPERTY DEVELOPERS:
Caloosa hatch ee R ive r
PROJECT LOCATION
1938 Hill Avenue, Fort Myers, Florida 33901 Office: 239-334-6870 Fax: 239-334-7810 MARINE and ENVIRONMENTAL CONSULTANTS
M ar sh
A ve nu e
Se ab oa rd
S tre et
Ve ro ni ca
S
S ho em ak er B lv d.
Palm Beach Bouleva rd
Michigan Avenue
Ra ilro ad
Ballard Road
Martin Luther King Jr. Boulevard
AutoCAD SHX Text
PALM BEACH
AutoCAD SHX Text
MIAMI
AutoCAD SHX Text
AVE
AutoCAD SHX Text
AVE
AutoCAD SHX Text
AVE
AutoCAD SHX Text
DAYTONA
AutoCAD SHX Text
BID PLANS, NOT FOR CONSTRUCTION
AutoCAD SHX Text A
AutoCAD SHX Text C
AutoCAD SHX Text Y
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text S
AutoCAD SHX Text M
AutoCAD SHX Text F
AutoCAD SHX Text O
AutoCAD SHX Text R
AutoCAD SHX Text T
AutoCAD SHX Text I
AutoCAD SHX Text L
AutoCAD SHX Text O
AutoCAD SHX Text R
AutoCAD SHX Text F
AutoCAD SHX Text O
AutoCAD SHX Text F
AutoCAD SHX Text I
AutoCAD SHX Text T
AutoCAD SHX Text Y
AutoCAD SHX Text D
-3.5'
-4'
-3.0'
-4'
-3.5'
-3.0'
Overall Site Plan
SCALE: 1" = 100'
City of Fort Myers Riverside Dock and Pier
Caloosahatchee River
SECTION: 7
TOWNSHIP: 44 S
RANGE: 25 E
SHEET
0 50 100
1938 Hill Avenue, Fort Myers, Florida 33901 Office: 239-334-6870 Fax: 239-334-7810 MARINE and ENVIRONMENTAL CONSULTANTS
Lee County Aerial 2022
11-5-24
NOG
2/13
Se ab oa rd
S t.
Royalston Ave.
E R ive rsi de
D .r
Property Line
Property Line
Detail A
Note: Property lines reference Lee County Property Appraiser. Water depths reference tide station 872-5520.
MHW @ 0.06' NAVD, MLW @ -0.89' NAVD.
Detail B
Detail C
Sidewalk to be replaced
AutoCAD SHX Text
FEET
AutoCAD SHX Text
SCALE
AutoCAD SHX Text October 28, 2024 11:15:21 a.m.
AutoCAD SHX Text Drawing: FTM37MASTER.DWG
BID PLANS, NOT FOR CONSTRUCTION
Detail A - Pier Replacement
SCALE: 1" = 30'
City of Fort Myers Riverside Dock and Pier
Caloosahatchee River
SECTION: 7
TOWNSHIP: 44 S
RANGE: 25 E
SHEET
0 15 30
1938 Hill Avenue, Fort Myers, Florida 33901 Office: 239-334-6870 Fax: 239-334-7810 MARINE and ENVIRONMENTAL CONSULTANTS
Lee County Aerial 2022
11-5-24
NOG
3/13
Property Line
This item has been digitally signed and sealed by Hans J.M. Wilson on the date adjacent to the seal.
Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies.
20'
10'
Proposed 10'w x 20'l covered deck section
Proposed 20' x 20' observation pier to be replaced in existing footprint
Proposed 6'w x 291'l main access dock to be replaced in existing footprint
6' 15' o.c. (Typ.)
A A
B
B
Note: Property lines reference Lee County Property Appraiser. Water depths reference tide station 872-5520.
MHW @ 0.06' NAVD, MLW @ -0.89' NAVD.
Existing seawall
Proposed solar lighting assembly at approximate 75' intervals (varies slightly) for total of (5) assemblies.
Lights to be located at bents (typ).
75'
110'
178'
10'
Proposed fire suppression stand pipe locations at approximate 145' intervals (varies slightly) for total of
(5) assemblies. Standpipes to be located at handrail posts per Hose Connection Detail
Sidewalk to be replaced
Proposed riprap over geotextile, 32cy of 12" - 18" stone
Existing light feature to remain
AutoCAD SHX Text
FEET
AutoCAD SHX Text
SCALE
AutoCAD SHX Text October 28, 2024 11:15:21 a.m.
AutoCAD SHX Text Drawing: FTM37MASTER.DWG
AutoCAD SHX Text %%OHANS J.M. WILSON%%o
AutoCAD SHX Text
REGISTERED PROFESSIONAL ENGINEER
AutoCAD SHX Text
FLORIDA REGISTRATION NO. 39680
AutoCAD SHX Text
DATE:____________________
AutoCAD SHX Text
CA. LIC. NO. 8519
Detail B - Dock Renovations
SCALE: 1" = 30'
Caloosahatchee River
Hurricane damaged fixed wood main access dock to be replaced in existing footprint
Property Line
Note:
DEP permit No.: 36-0199469-001 COE permit No.: SAJ-2002-03456
SECTION: 7
TOWNSHIP: 44 S
RANGE: 25 E
SHEET
0 15 30
1938 Hill Avenue, Fort Myers, Florida 33901 Office: 239-334-6870 Fax: 239-334-7810 MARINE and ENVIRONMENTAL CONSULTANTS
Lee County Aerial 2022
11-5-24
JWA
4/13
244' 24'
6'
Proposed 6'w x 24'l floating paddlecraft launch as manufactured by Accu Dock, to replace damaged floating dock
This item has been digitally signed and sealed by Hans J.M. Wilson on the date adjacent to the seal.
Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies.
City of Fort Myers Riverside Dock and Pier
AutoCAD SHX Text
FEET
AutoCAD SHX Text
SCALE
AutoCAD SHX Text October 28, 2024 11:15:21 a.m.
AutoCAD SHX Text Drawing: FTM37MASTER.DWG
AutoCAD SHX Text %%OHANS J.M. WILSON%%o
AutoCAD SHX Text
REGISTERED PROFESSIONAL ENGINEER
AutoCAD SHX Text
FLORIDA REGISTRATION NO. 39680
AutoCAD SHX Text
DATE:____________________
AutoCAD SHX Text
CA. LIC. NO. 8519
Detail C - Kayak Launch Plan
SCALE: 1" = 5'
Note:
DEP permit No.: 36-0199469-001 COE permit No.: SAJ-2002-03456
SECTION: 7
TOWNSHIP: 44 S
RANGE: 25 E
SHEET
0 2.5 5
1938 Hill Avenue, Fort Myers, Florida 33901 Office: 239-334-6870 Fax: 239-334-7810 MARINE and ENVIRONMENTAL CONSULTANTS
Lee County Aerial 2022
11-5-24
JWA
5/13
Caloosahatchee River
C
C
D D
24'
6'
6' (typ.)
10' o.c. (typ.)
Proposed 10" butt dia. wooden piling a minimum of 20' overall pile length. Piles to be wrapped with HDPE from 2' above MHW to 1' below mud line (Typ.)
E
E
City of Fort Myers Riverside Dock and Pier
Proposed 10' butt dia. wooden piling (3 total) for the floating paddlecraft launch to be 35' in length with the top driven to elevation 13.0' NAVD. Piles to be wrapped with HDPE from 2' above MHW to 1' below mud line (typ.)
Proposed Accu Dock paddlecraft launch float 6' x 24' Low Profile single section dock to be designed per manufacturer
Proposed 6'w x 268'l fixed wood access with Micro-Mesh decking to be built in the existing footprint
Proposed tidal mooring system
AutoCAD SHX Text
FEET
AutoCAD SHX Text
SCALE
AutoCAD SHX Text October 28, 2024 11:15:21 a.m.
AutoCAD SHX Text Drawing: FTM37MASTER.DWG
0 2 4
Hans J.M. Wilson on the date adjacent to the seal.
Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies.
MHW= (+)0.06 NAVD88
MLW= (-)0.89 NAVD88
Cross Section A-A
SCALE: 1" = 4'
City of Fort Myers Riverside Dock and Pier
SECTION: 7
TOWNSHIP: 44 S
RANGE: 25 E
SHEET1938 Hill Avenue, Fort Myers, Florida 33901 Office: 239-334-6870 Fax: 239-334-7810 MARINE and ENVIRONMENTAL CONSULTANTS
11-5-24
NOG
6/13
Existing Grade (varies)
Proposed handrail to be replaced See Handrail Detail
Proposed 10'w x 20'l roof over covered deck section
20' x 20' observation pier to be replaced in existing footprint
10' Proposed 6'w x 291'l main access dock to be replaced in existing footprint
Proposed 3" x 12" No. 1 dense cap boards chamfered, not to extend past outer alignment of piles, and fastened with (2) 5
8 " dia. all thread bolts, per pile (typ.)
Proposed 3" x 12" No. 2 grade stringers installed 18" on centers max with hurricane grade twist straps (typ.)
42" 5'
15' (typ.)
along length of acess10'
~6.0' NAVD
Note: Property lines reference Lee County Property Appraiser. Water depths reference tide station 872-5520.
MHW @ 0.06' NAVD, MLW @ -0.89' NAVD.
See lighting assembly
Existing cross bracing to be reused with new hardware.
All proposed piling to be new piles wrapped with HDPE pile wrap at 1' below the mudline to 2' above MHW.
10'
AutoCAD SHX Text
FEET
AutoCAD SHX Text
SCALE
AutoCAD SHX Text %%OHANS J.M. WILSON%%o
AutoCAD SHX Text
REGISTERED PROFESSIONAL ENGINEER
AutoCAD SHX Text
FLORIDA REGISTRATION NO. 39680
AutoCAD SHX Text
DATE:____________________
AutoCAD SHX Text
CA. LIC. NO. 8519
AutoCAD SHX Text October 28, 2024 11:15:21 a.m.
AutoCAD SHX Text Drawing: FTM37MASTER.DWG
Hans J.M. Wilson on the date adjacent to the seal.
Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies.
Covered Deck Details
SCALE: 1" = 5'
City of Fort Myers Riverside Dock and Pier
SECTION: 7
TOWNSHIP: 44 S
RANGE: 25 E
SHEET1938 Hill Avenue, Fort Myers, Florida 33901 Office: 239-334-6870 Fax: 239-334-7810 MARINE and ENVIRONMENTAL CONSULTANTS
11-5-24
CRY
7/13
0 2.5 5
CONNECTION SCHEDULE
MARK MANUFACTURER NO. TYPE UPLIFT CAP. NOTES/FASTENERS
1 SIMPSON LS70 560 10 - 10D NAILS
2 SIMPSON H16S 1470 10 - 10D NAILS
3 SIMPSON HCP1.81 605 6 - 10D NAILS
2 3
4 SIMPSON HRC22 480 6 - 10D NAILS
DESIGN WIND SPEED 160 MPH (3 SEC GUST)
BASIC WIND SPEED 110 MPH
WIND IMPORTANCE FACTOR 1.0
WIND EXPOSURE D
ADJUSTMENT FACTOR
INTERNAL PRESSURE COEFFICIENT N/A
COMPONENTS AND CLADDING
INTERIOR ROOF +16.0PSF / -27.0 PSF
EDGE ROOF +16.0 PSF / -53.3 PSF
CORNER ROOF +16.0 / -53.3 PSF
WINDOWS AND DOORS - N/ANote: If any of the connectors shown are not obtainable, it is acceptable that an equal connector is used and the engineer is notified of the change
Notes:
1. This drawing does not intend to show truss quantities
2 General contractor is responsible for all temporary bracing
3 If truss uplift conditions exceed strapping specifications, the contractor must notify the designer prior to installation of the trusses
4. Trusses are designed to meet all load interaction, uplift, and lateral load requirements along with the information provided on this drawing
5. Contractor to coordinate all temporary bracing with H1B 91 specs
6. Provide grade 2 lumber for rafters
2" x 10" hip jack rafter
2" x 8" common rafter at 16" on center
2" x 10" fascia board
12" dia. butt piling, min.
40' in length to be installed to provide minimum of 2,000lb uplift resistance (roof piling only)
(2) 5 8 " x stainless steel bolts, nuts and washers through piling and beam. Beam to be #2 SYP PT. Piling to be notched to accept (2) 2" x 12" beam as required
H16S twist strap at each rafter to beam connection
2" x 10" PT wood fascia with 2" galvanized drip edge
2" x 10" PT wood ridge board 2" x 8" PT wood common rafter @ 16" on center 2" x 4" PT wood purlins @ 16" on center GALVALUME ® ribbed metal roof sheathing
Purlins to be screwed to rafters with #10- 3" SS screws , (2) per purlin, at each rafter connection
Roof decking to be attached in accordance to section
1507.5 2001 FBC. ASTM A 653 G-90 zinc coated and installed per manufacturer's specifications
7'
0 2.5 5
Purloins not shown Provide roof pitch of 6:12
# Denotes typical connector for similar situations unless otherwise noted
AutoCAD SHX Text %%OHANS J.M. WILSON%%o
AutoCAD SHX Text
REGISTERED PROFESSIONAL ENGINEER
AutoCAD SHX Text
FLORIDA REGISTRATION NO. 39680
AutoCAD SHX Text
DATE:____________________
AutoCAD SHX Text
CA. LIC. NO. 8519
AutoCAD SHX Text October 28, 2024 11:15:21 a.m.
AutoCAD SHX Text Drawing: FTM37MASTER.DWG
AutoCAD SHX Text
BID PLANS, NOT FOR CONSTRUCTION
AutoCAD SHX Text
FEET
AutoCAD SHX Text
SCALE
AutoCAD SHX Text
FEET
SCALE
MHW= (+)0.06 NAVD88
MLW= (-)0.89 NAVD88
Existing Grade (varies)
Cross Section B-B SCALE: Varies
City of Fort Myers Riverside Dock and Pier
SECTION: 7
TOWNSHIP: 44 S
RANGE: 25 E
SHEET
0 1.5 3
1938 Hill Avenue, Fort Myers, Florida 33901 Office: 239-334-6870 Fax: 239-334-7810 MARINE and ENVIRONMENTAL CONSULTANTS
11-5-24
NOG
8/13
6'w x 291'l main access dock to be replaced in existing footprint
10' x 10' observation deck to be replaced in existing footprint
2" x 6" side rail
2" x 6" cap rail
4" x 4" post secured with double 3
8 " dia.
carriage bolts (5' o.c.)
5" clearance
3" sq.
Drive SS Screws
Existing cross bracing to be reused with new hardware. Proposed 10" butt dia. wooden piling a minimum of 35' overall length. Piles to be wrapped with HDPE pile wrap at 1' below the mudline to 2' above MHW.
42"
Proposed 3" x 12" No. 1 Dense cap boards chamfered, not to extend past outer alignment of piles, and fastened with (2) 5
8 " dia. all thread bolts, per pile (typ.)
Proposed 3" x 12" No.
2 grade stringers installed 18" on centers max with hurricane grade twist straps (typ.)
2" x 2" balusters on 5" centers (typ.)
0 1 2
Handrail Detail SCALE: 1" = 2'Cross Section B-B
SCALE: 1" = 3'
5" clearance
5' spacing (typ.)
42" (typ.)
3" sq. Drive SS Screws
Proposed 3" x 12" No. 1 Dense cap boards chamfered, not to extend past outer alignment of piles, and fastened with (2) 5
8 " dia. all thread bolts, per pile (typ.)
~6.0' NAVD
Note: Property lines reference Lee County Property Appraiser. Water depths reference tide station 872-5520.
MHW @ 0.06' NAVD, MLW @ -0.89' NAVD.
Proposed Micro-Mesh 1 1 2 " deep x 3
4 "
sq. top mesh decking to be secured with FiberGrate M-Clips spaced 24" max at each direction (typ.)
M-Clip Plan View
Proposed M-Clip
Proposed #8 x 2 2 " L wood screw
M-Clip Section View
Proposed #8 x 2 1
2 " L wood screw
Proposed M-Clip
Proposed stringer
Proposed 1 1 2 " deep Micro-Mesh
3" x 12" Stringer
Not To Scale Not To Scale
4" x 4" post secured with double 8 " dia. carriage bolts (5' o.c.)
AutoCAD SHX Text
FEET
AutoCAD SHX Text
SCALE
AutoCAD SHX Text October 28, 2024 11:15:21 a.m.
AutoCAD SHX Text Drawing: FTM37MASTER.DWG
AutoCAD SHX Text
FEET
AutoCAD SHX Text
SCALE
Cross Sections C-C & D-D
SCALE: 1" = 3'
SECTION: 7
TOWNSHIP: 44 S
RANGE: 25 E
SHEET
0 1.5 3
1938 Hill Avenue, Fort Myers, Florida 33901 Office: 239-334-6870 Fax: 239-334-7810 MARINE and ENVIRONMENTAL CONSULTANTS
11-5-24
JWA
9/13
Paddlecraft launch float by Accu Dock
Approximate existing grade
Proposed 10' butt dia. wooden piling (3 total) for the floating paddlecraft launch to be 35' in length with the top driven to elevation 13.0' NAVD. Piles to be wrapped with HDPE from 2' above MHW to 1' below mud line (Typ.).
Proposed 6'w x 268'l fixed wood access with Micro-Mesh decking to be built in the existing footprint
City of Fort Myers Riverside Dock and Pier
6'
Approximate existing grade
MHW= (+)0.06 NAVD
MLW= (-)0.89 NAVD
Proposed 6' x 24' single section Accu Dock floating paddlecraft launch to be designed per manufacturer
Cross Section D-D
Cross Section C-C
MHW= (+)0.06 NAVD
MLW= (-)0.89 NAVD
Proposed tidal mooring system, Seahorse Docking Heavy Duty Flex Slide is an acceptable product
24' Minimum 3" gap between fixed dock and floating launch
AutoCAD SHX Text
FEET
AutoCAD SHX Text
SCALE
AutoCAD SHX Text October 28, 2024 11:15:21 a.m.
AutoCAD SHX Text Drawing: FTM37MASTER.DWG
MHW= (+)0.06 NAVD88
MLW= (-)0.89 NAVD88
Proposed 4" x 4" toe rail
This item has been digitally signed and sealed by Hans J.M. Wilson on the date adjacent to the seal.
Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies.
6'
Cross Section E-E
SCALE: 1" = 2'
SECTION: 7
TOWNSHIP: 44 S
RANGE: 25 E
SHEET
0 1 2
1938 Hill Avenue, Fort Myers, Florida 33901 Office: 239-334-6870 Fax: 239-334-7810 MARINE and ENVIRONMENTAL CONSULTANTS
11-5-24
JWA
10/13
Proposed 2" x 4" x 12" block to elevate the toe rail
5'
See Toe Rail Detail
4"x4" toe rail lap splice (typ.)
3/8" carriage bolts w/ 2-1/2" fender washers (typ.)
Toe Rail Detail Not To Scale
Proposed 3" x 12" No. 2 stringers installed 18" on centers max (Typ.).
Proposed 3" x 12" No. 1 Dense cap boards chamfered, to extend past outer alignment of handrail, and fastened with (2) 5
8 " in dia.
all thread bolts, per pile (Typ.)
3'
Approximate existing grade
Proposed hurricane twist straps
Proposed 6'w x 268'l fixed main access dock to be replaced in existing footprint
M-Clip Plan View
Proposed M-Clip
Proposed #8 x 2 1 2 " L wood screw
M-Clip Section View
Proposed #8 x 2 2 " L wood screw
Proposed M-Clip
Proposed stringer
Proposed 1 1 2 " deep Micro-Mesh
3" x 12" Stringer
Not To Scale
Not To Scale
Proposed Micro-Mesh 1" deep x 3
4 " sq. top mesh decking to be secured with FiberGrate M-Clips spaced 24" max at each direction (Typ.)
City of Fort Myers Riverside Dock and Pier
2" x 4"x 12" block
Proposed 10' butt dia. wooden piling for the paddlecraft launch access dock to be 20 in length with the top driven to final grade. Piles to be wrapped with HDPE from 2' above MHW to 1' below mud line (Typ.).
3'
AutoCAD SHX Text %%OHANS J.M. WILSON%%o
AutoCAD SHX Text
REGISTERED PROFESSIONAL ENGINEER
AutoCAD SHX Text
FLORIDA REGISTRATION NO. 39680
AutoCAD SHX Text
DATE:____________________
AutoCAD SHX Text
CA. LIC. NO. 8519
AutoCAD SHX Text
FEET
AutoCAD SHX Text
SCALE
AutoCAD SHX Text October 28, 2024 11:15:21 a.m.
AutoCAD SHX Text Drawing: FTM37MASTER.DWG
SECTION: 7
TOWNSHIP: 44 S
RANGE: 25 E
SHEET
0 2 4
1938 Hill Avenue, Fort Myers, Florida 33901 Office: 239-334-6870 Fax: 239-334-7810 MARINE and ENVIRONMENTAL CONSULTANTS
11-5-24
CRY
11/13Lighting Assembly
SCALE: VARIES
City of Fort Myers Riverside Dock and Pier
This item has been digitally signed and sealed by Hans J.M. Wilson on the date adjacent to the seal.
Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies.
Proposed 4" x 4" wood post for railing (typ.)
Proposed 4" x 6" wood post to replace 4" x 4" at the lighting locations
Proposed 12W solar powered LED Walkway Light Code: SGDW012-5K as supplied by LED Lighting Solutions
Proposed Fibergrate 2" outside diameter fiberglass round tube
Proposed 4" x 6" wood post at the lighting locations
Proposed Fibergrate 2" outside diameter fiberglass round tube
Proposed FRP 4"x1-1/8"x1/4" channel
Proposed DX ® Engineering U-Bolt Saddle Clamp
Proposed 4" x 6" wood post at the lighting locations
Proposed Fibergrate 2" outside diameter fiberglass round tube
Proposed FRP 4"x1-1/8"x1/4" channel
Proposed DX ® Engineering U-Bolt Saddle Clamp
Lighting Assembly Plan View Not To Scale
Proposed FRP 4"x1-1/8"x1/4" channel
Proposed DX ® Engineering U-Bolt Saddle Clamp
Proposed 3/8" dia carriage bolt to include the FRP channel
Lighting Profile A-A Lighting Cross Section B-B 1" = 4'1" = 4'
Lighting Assembly Cross Section 1" = 1'
Lighting Assembly Profile View 1" = 1'
10'
See Lighting Assembly Profile View
See Lighting Assembly Cross Section View
See Lighting Assembly Plan View
0 0.5 1
AutoCAD SHX Text
FEET
AutoCAD SHX Text
SCALE
AutoCAD SHX Text October 28, 2024 11:15:21 a.m.
AutoCAD SHX Text Drawing: FTM37MASTER.DWG
AutoCAD SHX Text %%OHANS J.M. WILSON%%o
AutoCAD SHX Text
REGISTERED PROFESSIONAL ENGINEER
AutoCAD SHX Text
FLORIDA REGISTRATION NO. 39680
AutoCAD SHX Text
DATE:____________________
AutoCAD SHX Text
CA. LIC. NO. 8519
AutoCAD SHX Text
BID PLANS, NOT FOR CONSTRUCTION
AutoCAD SHX Text
FEET
SCALE
Technical Specifications SHEET1938 Hill Avenue, Fort Myers, Florida 33901
Office: 239-334-6870 Fax: 239-334-7810 MARINE and ENVIRONMENTAL CONSULTANTS JWA
12/13
TECHNICAL SPECIFICATIONS
TS-1.0 Mobilization and Demobilization
TS-1.1 Mobilization will include all activities and costs for transportation of personnel, equipment, and supplies/materials to the site, establishment of offices and other necessary facilities for the CONTRACTOR's operations at the site. Mobilization alone will not be considered as work in fulfilling the contract requirement for commencement of Work.
TS-1.2 Demobilization will include all activities and costs for transportation of personnel, equipment, and supplies/materials not used in the
Contract, including the disassembly, removal, and site cleanup of any offices or other facilities assembled on the site for the construction.
Upon demobilization, the CONTRACTOR will restore all access areas to the same condition as prior to mobilization.
TS-1.3 This line item includes mobilization and demobilization required by the Project at the time of award. If additional mobilization and demobilization is required during the performance of the Work due to changed, deleted, or added items of Work, compensation for such costs will be awarded to the CONTRACTOR by the OWNER. Additional mobilization and demobilization resulting from an error on the
CONTRACTOR's behalf will be solely the responsibility of the CONTRACTOR.
TS-1.4 All equipment and materials will be mobilized and demobilized in accordance with all local, state, and federal laws related to transportation and safety.
TS-2.0 Demolition and Disposal
TS-2.1 Demolition will include the removal of the existing over the water structures to be rebuilt and to include existing sidewalk / walkway to be replaced as noted on the plans. All piling are to be removed in their entirety. All demolition material will be removed from the site and disposed of properly. Reusable material will be notified to the CONTRACTOR by the Engineer. Proper disposal is the responsibility of the
CONTRACTOR. In addition, the construction will be done to accommodate navigation.
TS-3.0 Fixed Pier, Fixed Dock, & Floating Launch Construction, Materials, and Testing
Design Live Load 100 psf for Commercial
Decking Micro-Mesh ® 1" Deep x 3/4" Sq Top Mesh or Engineer Approved Equal
Pier Piling 10” butt diameter, 35' Minimum Length, 2.5pcf CCA treated
Roof Piling 12” butt diameter, 40' Minimum Length, 2.5pcf CCA treated
Dock Piling 10” butt diameter, 20' Minimum Length, 2.5pcf CCA treated
Floating Launch Piling 10" butt diameter, 35' Minimum Length, 2.5pcf CCA treated
Stringers 3"x12" #2 S4S Southern Yellow Pine on 18” centers max
Cap boards Double 3”x12” #1 Dense Rough Sawn Southern Yellow Pine
Cross Bracing 3" x 10" structural plastic lumber or Engineer approved equal fastened w/ (1) 5/8" dia. stainless steel through bolts
TS-3.1 Decking - Decking material will be Micro-Mesh ® 1" Deep x 3/4" Sq Top Mesh . Decking will be secured with a Type 316SS M-Clip spaced every 24" max per stringer. Each M-Clip will be secured with a #8 2-1/2" L Wood SS Screw. Installation methods will follow the
FiberGrate ® 1-1/2" Deep Micro-Mesh® Molded Grating Engineering Specifications. Decking panels will be 4'w x 12'l panels and be fabricated per manufacturer recommendations if the panels do not match the substructure configuration.
TS-3.2 Stringers - Stringers will be #2 Dense Southern Yellow Pine treated with Chromium Copper Arsenate (CCA) with a minimum retention of 0.6 pcf. Lumber will be finished dimensional lumber(S4S) . The outboard stringers will be scabbed not less than 18" per stringer end. The scab will be nailed to the stringer, with not less than (4) 30d stainless steel ringshanked nails per stringer end. The scab and stringer will be bolted with (1) 5/8” diameter through bolt, washers, and nuts to proximate piles. The intermediate stringers may be lapped not less than 18", or may be scabbed not less than 18" per stringer end. Lapped stringers will be attached with not less than (4) 30d stainless steel ringshanked nails. One 90-degree stainless steel twist strap will be installed on each stringer, one per pile bent. All bolts, washers and nuts will be stainless steel.
TS-3.3 Cap Boards - Cap boards will be #1 Dense Rough Sawn Southern Yellow Pine treated with Chromium Copper Arsenate (CCA) with a minimum retention of 0.6 pcf. Cap boards will be double bolted with 5/8” diameter through bolts, washers, and nuts. Cap board ends will be chamfered at a 45° angle and will extend 6" past the outer alignment of the pilings. Attachment hardware will be trimmed back to the nut and sanded to ensure there are no sharp edges from the trimming. All bolts, washers and nuts will be stainless steel.
TS-3.4 Piling - All proposed pilings will be of Southern Yellow Pine meeting ASTM D25 specifications. Piling will be treated with
Chromate Copper Arsenate (CCA) with a minimum retention of 2.5 pcf. All piling will be clearly and permanently marked with a brand, or a manufacturer's certification which contains the following information; suppliers' brand, plant designation, month and year of treatment, species of timber, length and class of pile, type and retention of preservative used for treatment. All pilings will be driven or jetted into the bottom. If driven, care must be taken not to damage the piles. All piling will have a minimum overall pile length as noted in T.S-3.0
The top of all piles will be driven or jetted in such a manner that all finished pile head surfaces will be on a horizontal plane unless noted otherwise. The CONTRACTOR will provide evidence, such as a report or other documentation from a geotechnical/engineering testing firm, that the pilings meet the required bearing capacity of 1.5 tons per piling. CONTRACTOR may determine capacity with either a static test load or by blow counts while driving piles. The Contractor will install High Density Polyethylene (HDPE) pile wrap on all CCA treated piling from 1' below the mud line to 2' above the MHW line. The pile wrap will be commercial grade, minimum 30-mil thickness with a minimum of a 24" overlap. Before installing wrap, pile will be cleaned, removing all foreign matter for the entire length to be protected. This includes all existing surface projections (i.e., nails, bolts, large splinters) and any other surface defects that would penetrate or damage the wrap. Wrap will be secured with stainless steel nails on 4” centers along the seam and around the upper and lower rims, in accordance with manufacturer's requirements.
TS-3.5 Floating Dock Structure - OWNER will coordinate with the CONTRACTOR on delivery and assembly of the floating paddlecraft launch. It is anticipated that the floating dock structure will be an ACCU Dock® single float and installed per manufactures specifications.
The floating launch will be secured to its piling by use of tidal moorings, to be installed on all piling, atop of the HDPE pile wrap.
TS-3.6 Hand Rail - Railing posts for the pier handrail will be double bolted to the stringers with 3/8" dia. carriage bolts, washers and nuts.
Bolts will be of an appropriate length for the application. Where stringers are not flush with edge of decking a block of stringer lumber 6" in length will be used as a spacer between the proximate stringer and the post. Top side rails and bottom side rails will be fastened with stainless steel 3" square drive stainless steel decking screws (2) per post. Top side rails and bottom side rails will be butt spliced with stainless steel 3" square drive stainless steel decking screws (2) per board end. Top side rails and bottom side rails will be installed with joints between boards positioned such that they occur at rail posts only. The cap rails will be fastened to the top side rail using 3" square drive stainless steel decking screws @ 12" on center minimum. Cap rails will have lap joints as shown in the plan detail. Balusters will be pre-drilled and fastened to the top side rail and bottom side rail using 3" square drive stainless steel decking screws (2) per rail.
TS-3.7 Toe Rail - Toe rail shall be #1 dense Southern Yellow Pine pressure treated with Chromium Copper Arsenate (CCA) with a minimum retention of 0.6 pcf. , set on top of spacer blocks and fastened to the deck with 3/8” carriage bolts, washers and nuts (2) per spacer. Bolts shall be of an appropriate length for the application. Toe rails shall be installed using lap joints positioned such that they occur at spacer locations only. Lap joints shall be as shown in the plan detail.
TS-4.0 Lighting and Infrastructure
Lighting 12W Solar Powered LED Walkway Light Code: SGDW012-5K supplied by LED Lighting Solutions
Tubing FIBERGRATE Fiberglass Round Tube: 2" Outside dia.
Bolts DX ® Engineering U-Bolt 2" Saddle Clamp in stainless steel
Posts 4" x 6" wood posts 0.6 pcf CCA treated
Channels Bedford FRP 4"x1-1/8"x1/4"TS-5.1
The preceding list of components are to be assembled in accordance with the plan sheet for the Lighting Assembly. Contractor will acquire and assemble a total of (5) lights, to be located as shown on the Pier Replacement Detail sheet.
TS-5.0 Sidewalk / Walkway - Sidewalk is conform to City of Fort Myers Technical Specifications, Section 03310, Cast-In Place
Concrete unless noted otherwise in this specification. All proposed sidewalk and walkways will be 6" thick, FDOT Class I, 3,000 psi concrete, without reinforcing. Where abutting existing concrete or asphalt a 4" tall x
" thick expansion joint material will be placed the length of the seam. At maximum 100' intervals there will be an expansion joint placed perpendicular to the sidewalk. Control cracks to be cut a minimum of 1-1/2" deep, 5' o.c.
This item has been digitally signed and sealed by Hans J.M. Wilson on the date adjacent to the seal.
Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies.
11-5-24 City of Fort Myers Riverside Dock and Pier
AutoCAD SHX Text October 28, 2024 11:15:21 a.m.
AutoCAD SHX Text Drawing: FTM37MASTER.DWG
AutoCAD SHX Text %%OHANS J.M. WILSON%%o
AutoCAD SHX Text
REGISTERED PROFESSIONAL ENGINEER
AutoCAD SHX Text
FLORIDA REGISTRATION NO. 39680
AutoCAD SHX Text
DATE:____________________
AutoCAD SHX Text
CA. LIC. NO. 8519
Fire i n i n in in in in i n
3in
3in
3in
3in
3in
4in4in4in4in i n i n i n i n i n in in in in in in in in in i n
DATUM: NAVD88
SCALE: Varies
SHEET:13/13DRAFTER: JAW
DATE: 5/11/24 FILE: Ftm37
0' 15' 30'
Fire Protection Plans
1938 Hill Avenue, Fort Myers, Florida 33901 Office: 239-334-6870 Fax: 239-334-7810 MARINE and ENVIRONMENTAL CONSULTANTS
Riverside Dock & Pier Replacement
Applicable Design Standards
Caloosahatchee River
Authority Having Jurisdiction (AHJ) : City of Fort Myers Fire Department
Adopted Design Standards : NFPA 14, 2019 Edition & NFPA 303, 2021 Edition
Standpipe Placement Requirements NFPA 303, 2021, 6.3.1 : Class I standpipe systems shall be provided for piers, bulkheads, and buildings where the hose lay distance from the fire apparatus exceeds 150 ft.
NFPA 303, 2021, 6.3.3 : Class I standpipe systems, where installed, shall be in accordance with NFPA 14 except for the provisions identified in 6.3.4.
NFPA 303, 2021, 6.3.4 : Hose racks, hoses, and standpipe cabinets shall not be required on piers and bulkheads.
NFPA 14, 2019, 13.4.2.3.6 : Fire department connections shall be located not more than 100 ft from the nearest fire hydrant or approved water supply.
NFPA 14, 2019, 13.4.2.3.7 : The location of the fire department connection shall be permitted to exceed 100 ft subject to the approval of the AHJ.
NFPA 14, 2019, 13.5.1.2 : Where required to be provided, hose connections shall be located in accordance with 13.5.1.2.
NFPA 14, 2019, 13.5.1.2.1 : Hose connections shall be provided every 150 ft.
NFPA 14, 2019, 13.5.1.2.3 : Hose connections shall be provided so that all portions of the walking surface of the pier, dock, or similar structure are within 130ft of a hose connection.
FDC & Hose Connection Height Requirements NFPA 14, 2019, 13.5.1.1.1 : Hose connections and hose stations shall be unobstructed and shall be located less than 3ft or more than 5ft above the walking surface where they are installed.
NFPA 14, 2019, 13.5.1.1.1.1 : This dimension shall be measured from the walking surface to the center of the hose valve.
NFPA 14, 2019, 13.4.2.3.8 : Fire department connections shall be located not less than 18 in and not more than 48 in above the level of the adjoining ground, sidewalk, or grade surface.
134'
Fire Extinguishers Not Required NFPA 303, 2021, 6.1.1.1.1 : Placement of portable fire extinguishers on piers and along bulkheads where vessels are permitted to be moored shall meet the following criteria:
(1) Extinguishers listed for Class A, Class B, and Class C fires shall be installed at the pier/land intersection on a pier that exceeds 25 ft in length.
(2) Additional fire extinguishers shall be placed such that the maximum travel distance to an extinguisher does not exceed 75 ft.
(3) Extinguishers shall be protected from environmental exposures to prevent damage and lack of operability.
Technical Specifications: Fire Protection System Materials, Construction, & Testing
TS-1.1 Upland Fire Lines - Fire lines located on the upland will be buried a minimum of 30" below the finished grade.
TS-1.2 HDPE Pipe - All HDPE pipe will be SRD11 rated for a minimum safe working pressure of 200 psi.
TS-1.3 Hangers - Fire lines will be secured with appropriately sized stainless steel hangers and fasteners to the wooden substructure. Hangers will be attached to the stringers. Hangers will not exceed a maximum of 4' spacing
TS-1.4 Hardware - All fittings, hangers, and other hardware will be 316 stainless steel, unless otherwise noted.
TS-1.5 90° Elbow - All 90° elbows will be long radius bends.
TS-1.6 Materials - All valves, connections, or other materials used in construction will be installed per the manufactures specifications and recommendations.
TS-1.7 Testing - The CONTRACTOR will provide all fire flow, pressure test, or other testing required by the AHJ to secure and close out all local building permits. The CONTRACTOR will make any repairs or other adjustments necessary to pass final testing with the AHJ.
TS-1.8 Excavation - The CONTRACTOR is responsible for all directional bores or trenching required to install the fire protection system on the upland. The CONTRACTOR will be required to repair any pavement disturbed during installation. If directional bores are performed it will be the CONTRACTORS responsibility to provide the bore and repair any incidental damage to utilities. Care must be taken to avoid damaging or disturbing of tiebacks when trenching near seawalls.
TS-1.9 Existing Utilities - The CONTRACTOR is responsible for performing all testing or surveying deemed necessary to locate and avoid existing utilities within the project area.
Existing fire hydrant
NOTE: Property lines per Lee County Property Appraiser. Refer to Pier/Dock Replacement plans by HWA for pier dimensions, materials, and connections.
Call 48 Hours before you dig in Florida It's the Law
Sunshine State one call of Florida, Inc
Structural members and connections per Pier Replacement Plans by HWA.
Outline of Riverside Dock per construction plans by HWA
Hose connection per details
15'
155'125'
Proposed Riverside Dock FDC at base of Dock
Kayak Launch per construction plans by HWA
Hose Connection Detail
SCALE: 1" = 3"
36" min.
60" max.
Secure aluminum stand to outside stringer with SS through bolts
6" dia. 0.125" thick aluminum fire house valve stand painted white
3" SRD11 HDPE pipe housed in aluminum stand
Lee County Aerial 2023
Proposed Fire Protection Plan
SCALE: 1" = 30"
Property line per Lee County Property Appraiser
Outline of Riverside Pier per construction plans by HWA
Hose connection per details
58'
Approximate mean high water line
Proposed Riverside Pier FDC
2-1/2" hose valve
Aluminum stand through top rail
Side rails and pickets continuous
SRD11 HDPE pipe secured with stainless steel hangers on 4' centers, typ.
Fire line will transition under stringers
Hose Connection Detail
SCALE: 1" = 3"
SRD11 HDPE pipe secured with stainless steel hangers on 4' centers, typ.
Fire line will transition under stringers
2-1/2" hose valve
Aluminum stand through top rail
Secure aluminum stand to outside stringer with SS through bolts
Side rails and pickets continuous
Note: View shown from waterward side of pier
Fire Department Connection Detail
SCALE: 1" = 2"
24"x24"x4" thick concrete pad
Finished Grade
Guardian free standing FDC model No.
6224, or approved equal. Two (2) 2-1/2" fire department connections to 4" pipe.
90° long turn elbow
Label: "MANUAL DRY
STANDPIPE RIVERSIDE PIER"
SRD11 HDPE
30" min, Typ.
SS strap supporting pipe
4-1/2" x 4-1/2" x 1/2" stainless steel angle secured with SS through bolts
Core through seawall based on pipe size. Seal gap between pipe and wall with waterproof membrane.
Seawall Anchor Detail
SCALE: N.T.S.
SRD11 HDPE pipe secured with stainless steel hangers on 4' centers, typ.
45° Elbow
Existing vinyl seawall
Existing concrete cap
8'
Existing seawall per Lee County Aerial
Route fire line through seawall per Seawall Transition Detail
Riverside
PIER
Riverside
DOCK
SECTION: 7
TOWNSHIP: 44 S.
LATITUDE: 26°39'27" N
LONGITUDE: 81°51'11" W
RANGE: 25 E.
LEGEND:
Existing Fire Hydrant
Proposed Fire Department Connection
Proposed Hose Connection
Proposed 4" SRD11 HDPE
Proposed 3" SRD11 HDPE
4in
3in
4in
3in
Structural members and connections per Dock Replacement Plans by HWA.
Hose Connection Detail
SCALE: 1" = 3"
Fire Department Connection Detail
SCALE: 1" = 3"
Fire line will transition under stringers
36" min.
60" max.
2-1/2" Hose valve
Secure aluminum stand to outside stringer with SS through bolts
6" dia. 0.125" thick aluminum fire house valve stand painted white
SRD11 HDPE pipe secured with SS hangers on 4' centers, Typ.
Toe rail will be continues
3" SRD11 HDPE pipe housed in aluminum stand
Guardian clappered snoot check valve model number 6418/9 to 2-1/2" FDC
Fire line will transition under stringers
Secure aluminum stand to outside stringer with SS through bolts
6" dia. 0.125" thick aluminum fire house valve stand painted white
Toe rail will be continues
3" SRD11 HDPE pipe hosed in aluminum stand
90° angle
18" min.
48" max.
Structural members and connections per Dock Replacement Plans by HWA.
SRD11 HDPE pipe secured with SS hangers on 4' centers, Typ.
Label: "MANUAL DRY STANDPIPE
RIVERSIDE DOCK"
Riverside Pier Details Riverside Dock Details
Riverside Community Center Strap: 07-44-25-P4-00109.0010 Address: 3061 E Riverside Dr, Fort Myers Owner: City of Fort Myers
Structural members and connections per Pier Replacement Plans by HWA.
45° Elbow
110'
71'
64'
239' 24'
55'
55'
77'
120'
This item has been digitally signed and sealed by Hans J.M. Wilson on the date adjacent to the seal.
Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies.
AutoCAD SHX Text
FEET
AutoCAD SHX Text
SCALE
AutoCAD SHX Text October 28, 2024 11:15:21 a.m.
AutoCAD SHX Text Drawing: FTM37MASTER.DWG
AutoCAD SHX Text %%OHANS J.M. WILSON%%o
AutoCAD SHX Text
REGISTERED PROFESSIONAL ENGINEER
AutoCAD SHX Text
FLORIDA REGISTRATION NO. 39680
AutoCAD SHX Text
DATE:____________________
AutoCAD SHX Text
CA. LIC. NO. 8519
| Ftm37_01CoverRiverside |
| Sheets and Views |
| 01CoverRiverside |
| Ftm37_02OverallRiversidePier |
| Sheets and Views |
| 02OverallRiversidePier |
| Ftm37_03DetailA_Pier |
| Sheets and Views |
| 03DetailA_Pier |
| Ftm37_04DetailB_Dock |
| Sheets and Views |
| 04DetailB_Dock |
| Ftm37_05DetailC_Dock |
| Sheets and Views |
| 05DetailC_Dock |
| Ftm37_06XsAA_Pier |
| Sheets and Views |
| 06XsAA_Pier |
| Ftm37_07PierDetails |
| Sheets and Views |
| 07PierDetails |
| Ftm37_08XsBB_Pier |
| Sheets and Views |
| 08XsBB_Pier |
| Ftm37_09XsDD_Dock |
| Sheets and Views |
| 09XsDD_Dock |
| Ftm37_10XsEE_Dock |
| Sheets and Views |
| 10XsEE_Dock |
| Ftm37_11Lighting_Pier |
| Sheets and Views |
| 11Lighting_Pier |
| Ftm37_12TechSpecs |
| Sheets and Views |
| 12TechSpecs |
| Ftm37_13Fire_RiversidePier |
| Sheets and Views |
| 08Fire_RiversidePier |
File details come from the government source that posted it. Updated .