| FQ19210/WJ - Dual Rail E-Clip Installer Compliance Matrix | |
| Offeror: | ___________________________________________________________________ |
| Date: | ___________________________________________________________________ |
| Section | Title | Technical Specifications Reference | Requirement | Compliance Y/N/NA *Does your proposal meet the Specifications detailed in the Technical Specifications* | Notes |
| 1 | General Requirements | All Compliance Requirements in this Section refer to "Section 1 General Requirments" of the "Technical Requirements" starting on Page 1. | The proposal shall include layout and arrangement drawings showing all major equipment, including but not limited to: Cab, Engine, Transmission, Electrical system, work tools, lighting system. A description of each major subsystem of the unit, and a list of the make and model of all major components. | ||
| 2 | System Design | All Compliance Requirements in this Section refer to "Section 2 System Design" of the "Technical Requirements" starting on Page 5. | The unit shall fit in the dimensions of WMATA’s Track System as defined in section 2.1.3 | ||
| The unit shall meet the specified dimensions referenced in Figure 17.1.1 | |||||
| The unit cab shall be climate controlled, fully enclosed | |||||
| The unit shall be capable of clearing all of WMATA’s tracks, tunnels and structures as shown in Figures 17.1.2 and 17.1.3 | |||||
| The unit shall have handrails or grab irons installed per section 2.2.7 | |||||
| The proposal shall demonstrate that the vehicle meets traction requirements in section 2.3.1 The proposal shall include data/calculations used to prepare the proposal. | |||||
| The unit shall be capable of operating at max speed of 25 mph | |||||
| The proposal shall demonstrate that the vehicle meets braking requirements in section 2.3.2 The proposal shall include data/calculations used to prepare the proposal. | |||||
| The proposal shall demonstrate that the vehicle meets weight requirements in section 2.5 and drawing 17.1.1. The proposal shall include data/calculations used to prepare the proposal. | |||||
| The unit shall have a VMDS per section 2.8 | |||||
| 3 | Construction and Assembly | All Compliance Requirements in this Section refer to "Section 3 Construction and Assembly" of the "Technical Requirements" starting on Page 11. | The unit shall meet lifting point requirements per section 3.1.1 | ||
| The unit shall meet towing requirements per section 3.1.2 | |||||
| The frame and members of the vehicle shall meet the strength requirements contained in Section 3.2.a. A frame loading diagram of structural members including material type and thicknesses shall be submitted with the proposal. | |||||
| The unit shall meet Underframe equipment mounting requirements per section 3.3 | |||||
| 4 | Undercarriage | All Compliance Requirements in this Section refer to "Section 4 Undercarriage" of the "Technical Requirements" starting on Page 13. | The unit shall meet wheel requiremenmts per section 4.3.1 |
The unit shall meet axle requiremenmts per section 4.3.2
| 5 | Cab and Controls | All Compliance Requirements in this Section refer to "Section 5 Cab and Controls" of the "Technical Requirements" starting on Page 16. | The unit shall meet cab requirements per section 5.1 |
| The unit shall provide Seating for two persons per section 5.2 | |||
| The unit shall meet cab Window requirmeents per section 5.3 | |||
| The unit shall meet HVAC requirements per section 5.4 | |||
| The unit shall meet cab equipment requirements per section 5.5 | |||
| The unit shall meet cab control and indications requirements per section 5.6 |
| 6 | Diagnostic System | All Compliance Requirements in this Section refer to "Section 6 Diagnostic System" of the "Technical Requirements" starting on Page 21. | The unit shall meet Diagnostics requirements per section 6.1 |
| The diagnostic system shall meet signals requirements per section 6.2 | |||
| The diagnostic system shall meet sampling and storage requirements per section 6.3 | |||
| The diagnostic system shall meet Download requirements per section 6.4 | |||
| 7 | Electrical System | All Compliance Requirements in this Section refer to "Section 7 Electrical Equiptment" of the "Technical Requirements" starting on Page 24. | The unit shall meet grounding rerquirements per section 7.1 |
| The unit shall meet electrical rerquirements per section 7.3 | |||
| The unit shall meet batteries rerquirements per section 7.5 |
| 8 | Propulsion and Hydraulic Equipment | All Compliance Requirements in this Section refer to "Section 8 Propulsion and Hydraulic Equiptment" of the "Technical Requirements" starting on Page 26. | The engine shall meet the requirements per section 8.2. The proposal shall demonstrate that the vehicle meets traction requirements. The proposal shall include data/calculations used to prepare the proposal. |
| The exhaust system shall meet the requirements per section 8.3 | |||
| The air compressor system shall meet the requirements per section 8.5 | |||
| The fuel tank shall meet the requirements per section 8.6 | |||
| The hydraulic system shall meet the requirements per section 8.7 |
| 9 | Brake System | All Compliance Requirements in this Section refer to "Section 9 Brake System" of the "Technical Requirements" starting on Page 36. | Parking brake shall be failsafe spring applied and hold on a 6% grade |
| Service shall provide a deceleration of a least 2.5 mph/s |
| 10 | Communications | All Compliance Requirements in this Section refer to "Section 10 Communications" of the "Technical Requirements" starting on Page 37. | The radio system shall meet radio specifications per section 10.1 |
| The camera system shall meet specifications per section 10.2 |
| 11 | Lighting System | All Compliance Requirements in this Section refer to "Section 11 Lighting System" of the "Technical Requirements" starting on Page 39. | The unt shall have Exterior, interior work and perimeter lighting per section 11 |
| The unit shall have Emergency lighting per specification section 11.5 | |||
| 12 | Work Tools | All Compliance Requirements in this Section refer to "Section 12 Work Tools" of the "Technical Requirements" starting on Page 41. | The work tools shall meet or exceed the requirements per section 12.1 |
The unit shall have meet specified visibility requirements
| The Unit shall meet work head control requiremnts per section 12.3. |
| The Unit shall meet requiremnts per section 12.4. |
| The Unit shall meet work head lock requiremnts per section 12.5. |
| The Unit shall meet work head lubrication requiremnts per section 12.6. |
| The Unit shall meet requiremnts per section 12.7. |