Forest Service Pants Female Tech Data TDC Nov 8 2023.docx

DOCX document 25 KB Posted

Attached to
Pants, Flame Resistant Aramid Federal contract opportunity
Solicitation number
SPE1C124R0004
Issued by
Defense Logistics Agency Troop Support Clothing and Textiles

About this file

This document is a technical data package related to a federal contract opportunity for Pants, Flame Resistant Aramid, Female (Type I). The proposed solicitation is for Pants, Flame Resistant Aramid (Type I and Type II) for the U.S. Forest Service. The procurement will be an Unrestricted Indefinite Delivery contract with performance periods of four one-year tiers.

The key requirements include compliance with Forest Service specifications for the Type I and Type II pants, providing first article samples, and meeting packaging and marking requirements. The solicitation will use a Best Value Tradeoff Source Selection process, evaluating proposals on Product Demonstration Model, Past Performance, and Socioeconomic Support. A minimum quantity of 1,260 EA for Type I Female and 2,640 EA for Type I and 1,260 EA for Type II is guaranteed for the contract period, with annual order limitations of 10,710, 34,260, and 9,210 respectively per tier. Delivery is 180 days after award, with inspection at origin and FOB Destination.

View the file

Other files for this federal contract opportunity

Other files attached to Pants, Flame Resistant Aramid, newest first.
File Type Posted
Forest Service Pants Unisex Tech Data TDC Nov 8 2023.docx DOCX document
5100_92M (1) Pants Flame Resist.pdf PDF
5100_623A Pants Flame Resist Womens.pdf PDF
5100_88F Cloth Aramid Trousers.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SECTION C

PANTS, TYPE I: Female (PGC01008) RA001: THIS DOCUMENT INCORPORATES TECHNICAL AND/OR QUALITY REQUIREMENTS (IDENTIFIED BY AN 'R' OR AN 'I' NUMBER) SET FORTH IN FULL TEXT IN THE DLA MASTER LIST OF TECHNICAL AND QUALITY REQUIREMENTS FOUND ON THE WEB AT: http://www.dla.mil/HQ/Acquisition/Offers/eProcurement.aspx. FOR SIMPLIFIED ACQUISITIONS, THE REVISION OF THE MASTER IN EFFECT ON THE SOLICITATION ISSUE DATE OR THE AWARD DATE CONTROLS. FOR LARGE ACQUISITIONS, THE REVISION OF THE MASTER IN EFFECT ON THE RFP ISSUE DATE APPLIES UNLESS A SOLICITATION AMENDMENT INCORPORATES A FOLLOW-ON REVISION, IN WHICH CASE THE AMENDMENT DATE CONTROLS.

RP001: DLA PACKAGING REQUIREMENTS FOR PROCUREMENT

Q009: INSPECTION AND ACCEPTANCE AT ORIGIN

RQ002:

RQ011: REMOVAL OF GOVERNMENT IDENTIFICATION FROM NON-ACCEPTED SUPPLIES

RQ018: CONTRACTOR RETENTION OF SUPPLY CHAIN TRACEABILITY DOCUMENTATION (AUG 2016) This item requires supply chain traceability documentation in accordance with DLA Directive (DLAD) Procurement Notes #C03 Contractor Retention of Supply Chain Traceability Documentation (AUG 2016)#. The full text of C03 can be found in the DLAD Procurement Notes on the Web at: http://www.dla.mil/HQ/Acquisition/Offers/eProcurement.aspx.

(End of TQ Requirement)

IP056:

Article SizeFSCNIINNFES #UPC
X Small Short84150169535221538718020909387
X Small Regular84150169535251539718020764344
X Small Long84150169535261540718020935522
Small Short84150169535291541718020947846
Small Regular84150169535311542718020786056
Small Long84150169535341543718020644950
Medium Short84150169535351544718020635484
Medium Regular84150169535361545718020930152
Medium Long84150169535371546718020844282
Large Short84150169535381547718020624495
Large Regular84150169537051548718020854656
Large Long84150169537061549718020973135
X Large Short84150169537071550718020790657
X Large Regular84150169537081551718020927503
X Large Long84150169537091552718020775340
XX Large Short84150169537131553718020667348
XX Large Regular84150169537141554718020899480
XX Large Long84150169537151556718020934891

These items are procured in accordance with a United States Department of Agriculture, Forest Service specifications.

These Specifications are located at:

https://www.fs.usda.gov/t-d/fire_safety.php

PANTS, FLAME RESISTANT ARAMID, FEMALE (TYPE I): Shall be in accordance with Forest Service Specification 5100-623A, dated November 3, 2023 and MTDC drawing 1170 dated May 28, 2023.

Type I Color - Sage green

Cloth shall be in accordance with Forest Service Specification 5100-88F, dated November 8, 2023.

First article samples are required in accordance with 5100-623A.

Unit of issue - PR (pair)

DELETE CURRENT "BARCODE LABEL/TAG" REQUIREMENTS AND SUBSTITUTE THE FOLLOWING:

LABEL TAG: EACH ITEM SHALL BE INDIVIDUALLY BAR-CODED WITH A PAPER TAG FOR PERSONAL CLOTHING ITEMS. THE PAPER USED FOR THE TAGS SHALL BE STANDARD BLEACHED SULFATE HAVING A BASIS WEIGHT OF 100 POUNDS WITH A SMOOTH FINISH TO ACCEPT THERMAL TRANSFER AND DIRECT PRINTING. THE TAGS SHALL HAVE A HOLE AND SHALL BE ATTACHED TO EACH ITEM BY A FASTENER, CLEARLY LEGIBLE AND READABLE BY SCANNER. THE BAR CODING ELEMENT SHALL BE A 13 DIGIT NATIONAL STOCK NUMBER (NSN). THERE SHALL BE A 12 DIGIT UNIVERSAL PRODUCT CODE (UPC) ASSIGNED FOR ALL NSNS BY THE GOVERNMENT. THE INITIAL "UPC" MUST APPEAR BENEATH THE CODE. THE BAR CODES FOR NSN AND UPC SHALL BE A MEDIUM TO HIGH DENSITY AND SHALL BE LOCATED SO THAT THEY ARE COMPLETELY VISIBLE ON THE ITEM WHEN IT IS FOLDED AND PACKAGED AS SPECIFIED. THE LABEL'S LOCATION SHALL CAUSE NO DAMAGE TO THE ITEM.

NOTE: UNIVERSAL PRODUCT CODE INFORMATION THE GOVERMENT ASSIGNED UNIVERSAL PRODUCT CODE (UPC) MUST BE PLACED ON ALL SHIPPING CARTONS ON WHICH THE NSN APPEARS.

THE FOLLOWING DEFECTS APPLY FOR BARCODE LABELS/TAGS:

BAR CODE OMITTED OR NOT READABLE BY SCANNER

HUMAN-READABLE INTERPRETATION (HRI) OMITTED OR ILLEGIBLE

NOT VISIBLE ON FOLDED, PACKAGED ITEM CAUSES DAMAGE TO THE ITEM

NOTE: IF THE END ITEM IS PLACED IN A PLASTIC BAG - USE TYPE VII (PRESSURE SENSTIVE LABEL) OF MIL-DTL-32075.

IF THE END ITEM IS TIED IN A BUNDLE OR LEFT AS AN INDIVIDUAL ITEM, USE TYPE VIII (TAG, PAPER) OF MIL-DTL-32075.

MIL-DTL-32075: LABEL FOR CLOTHING, EQUIPAGE,

AND TENTAGE, GENERAL USE REPLACES DDD-L-20

INTERIM SPECIFICATION CHANGES TO MIL-DTL-32075:

PAGE 4, PARA. 3.3.5, AFTER "TYPE III OR IV, CLASS 4 OF" DELETE "DDD-L-20" AND REPLACE "MIL-DTL-32075,".

PAGE 6, TABLE I, "PHYSICAL REQUIREMENTS OF THE

TYPE VI FINISHED LABEL." UNDER "TEARING

STRENGTH" DELETE: "(LB.) MINIMUM" AND

SUBSTITUTE: "(GNS) MINIMUM."

PAGE 12, PARA 3.3.2.17, AFTER "NSN" ADD

"AND THE UNIVERSAL PRODUCT CODE (UPC)

SUPPLIED BY THE GOVERNMENT, FOR ALL NSNs."

ADDITIONAL INFORMATION FOR ANSI/ASQC Z1.4:

NOTE: THE MOST RECENT VERSION OF THIS DOCUMENT SHOULD BE USED.

APPLICATION FOR COPIES SHOULD BE ADDRESSED TO:

AMERICAN SOCIETY FOR QUALITY

600 NORTH PLANKINTON AVENUE

MILWAUKEE, WISCONSIN 53203

AQL'S:

Visual – S-4, 10.0 Dimensional - S-2, 4.00 Palletization - S-1, 6.5 Prep - S-2, 2.5

ACCEPTABILITY OF LOTS WILL BE DETERMINED BY THE USE

OF "SAMPLING PROCEDURES AND TABLES FOR INSPECTION BY ATTRIBUTES", ANSI/ASQC Z1.4 and Quality conformance inspections in accordance with end item specification (5100-623A).

Contractor is required to provide copies of third party certification to NFPA 1977.

Certificates of compliance (COC) are required for first article and lot inspection in accordance with end item specification (5100-92M). COCs for Basic material and thread shall be supported by test reports.

SECTION D

Case lot is 30 pants of one type and size only per box.

As a minimum item shall be packed in a snug fitting fiberboard shipping container conforming to ASTM-D-5118. Any commercial closure method cited in ASTM-D-1974 is acceptable except stapling. Packaging shall be as per ASTM-D-3951, MIL-STD-129 with change notice 4, MIL-STD-147. Lot numbering shall be in accordance with MIL-STD-129 AND DSCP-4155.3.

SPECIAL MARKING: The National Fire Equipment System (NFES) number appearing below the National Stock Number (NSN) of this Item Purchase Description shall be marked on the shipping container below the NSN. The NFES number shall be preceded by "NFES".

Packaging examination. The fully packaged end item shall be examined for the defects listed below. The lot size shall be expressed in units of shipping containers. The sample unit shall be one shipping container fully packaged. The Inspection level shall be S-2 and the AQL, expressed in terms of defects per hundred units, shall be 2.5.

Examine Defect

Marking Omitted; incorrect; illegible, of (exterior) improper size, location, sequence & Unit Pack, or method of application.

Materials Any component missing, damaged or not as specified.

Workmanship Inadequate application of components, such as: incomplete closure of container flaps, loose strapping, improper taping, or inadequate stapling. Bulged or distorted container.

Contents Number of intermediate containers per shipping container is more or less than required.

Number of items per container is more or less than required.

Palletization examination. The fully packaged and palletized end items shall be examined for the defects listed below. The lot size shall be expressed in units of palletized unit loads. The sample unit shall be one palletized unit load, fully packaged.

The Inspection level shall be S-1 and the AQL, expressed in terms of defects per hundred units, shall be 6.5.

Examine Defect

Finished Length, width or height exceeds Dimensions specified maximum requirement.

Palleti- Pallet pattern not as specified.

zation Interlocking of loads not as specified. Load not bonded with required straps as specified.

Weight Exceeds maximum load limits.

Marking Omitted; incorrect; illegible;

of improper size, location, sequence or method of appli-cation.

MIL-STD-129 CURRENT REVISION UNLESS OTHERWISE SPECIFIED

- DEPARTMENT OF DEFENSE STANDARD PRACTICE

- MILITARY MARKING FOR SHIPMENT AND STORAGE

INTERIM CHANGES:

OMISSION OF MARKINGS ON EXTERIOR SHIPPING CONTAINERS OF ITEMS

IN THE DLA TROOP SUPPORT CLOTHING AND TEXTILE (C&T) DIRECTORATE:

THE NOMENCLATURE AND MANUFACTURER'S NAME (WHEN THE NAME IDENTIFIES THE MATERIAL) SHALL BE OMITTED FROM ALL EXTERIOR SHIPPING CONTAINERS OF DLA TROOP SUPPORT C&T ITEMS, REGARDLESS OF MODE OF SHIPMENT.

IF THE MANUFACTURER'S NAME DOES NOT IDENTIFY THE MATERIAL AS BEING CLOTHING, IT MAY REMAIN. NSNS SHALL BE SHOWN ON ALL SHIPPING CONTAINERS OF C&T ITEMS, THE PACKING LIST SHALL BE PLACED INSIDE THE LAST CONTAINER TO BE LOADED FOR EACH SHIPMENT. THE WORDS "PACKING LIST HERE" SHALL BE STENCILED, NOT HAND LETTERED, ON THE CONTAINER.

MIL-STD-147 IS HEREBY REINSTATED AS FOLLOWS:

MIL-STD-147E DEPARTMENT OF DEFENSE

16 MAY 2008 STANDARD PRACTICE

PALLETIZED UNIT LOADS

STANDARDS (COMMERCIAL)

ASME-MH1 American Society of Mechanical Engineers (ASME) Pallets, Slip Sheets, and Other Bases For Unit Loads, for construction of pallets.