This document is a division of responsibilities diagram for a Door Access Control (DAC) System Request for Quotation (RFQ) for Forest Hills Public Schools. The diagram comprehensively details the installation responsibilities between the school district and the DAC vendor, clearly delineating which components will be provided and installed by the district's construction trades versus those to be handled by the access control vendor. The diagram meticulously maps out the infrastructure requirements, including pathways, electrical connections, networking equipment, sensors, and various door-related hardware such as electrified hardware, card readers, intercom stations, handicap controllers, and network infrastructure.
The diagram indicates that the DAC vendor will be responsible for providing and installing most technical components, including the DAC panel, network switch, patch panel, cabling with J-hooks, pathways, and door-related electronic hardware. The district or construction trades will handle fundamental infrastructure like electrical power, metal conduits, backing boards, and potential pre-existing infrastructure. The document notes that vendors may need to reuse existing infrastructure when possible or replace/add new components as necessary. A key highlight is the granular breakdown of responsibilities, showing specific installation details for components like REX and door contact sensors, intercom master stations, and various mounting boxes and connection points.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| FHPS DAC RFP APP C (1).pdf | ||
| FHPS DAC RFP Addendum 1.pdf | ||
| FHPS DAC RFP APP C.pdf | ||
| FHPS DAC RFQ APP D (1).pdf | ||
| FHPS Door Access Control System RFP (1).pdf | ||
| FHPS DAC RFP APP A (1).xlsx | XLSX spreadsheet | |
| FHPS DAC RFP APP A.xlsx | XLSX spreadsheet | |
| FHPS Door Access Control System RFP.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DAC panel
Equipment room wall fireproofing sleeve
J-hooks every 5 feet
Interior wall
Drop ceiling
10 feet service loop door frame
Provided and installed by the District or construction trades
DAC vendor to provide and install.
DAC vendor to reuse when possible, or alternatively replace or add new as needed
Forest Hills Public Schools – Door Access Control System RFQ – Appendix D Division of responsibilities for door access control (DAC) installation metal conduit and box electrical power backing board in equipment room
Door
Electrified hardware
(whether strike or door bar + transfer hinge, the connection point is on the frame side) pathways
1-gang box for card reader or keypad handicap push button Door release button / panic button pathway
Drop ceiling
Intercom master station handicap controller/ power supply/ maglock
1-gang box for intercom door station
To patch panel
To patch panel rack ladder core
Interior ceiling plenum space UTP addressable fire relay