L87750.pdf

PDF 143 KB Posted

Attached to
Removal of 3 Train Carts Federal contract opportunity
Solicitation number
FA930123Q0013
Issued by
Department of the Air Force Materiel Command Test Center

About this file

This document is a laboratory analysis report from EMC Labs analyzing lead content in paint chip samples taken from Building 6004 at Edwards Air Force Base. The report details lead testing on five interior and exterior paint chip samples collected by the client in September 2021. Sample 6004-CE-1L had 16.6% lead by weight, sample 6004-CE-2L had 0.336% lead, sample 6004-CE-3L had 0.470% lead, sample 6004-CE-4L had 9.45% lead, and sample 6004-CE-5L had 0.297% lead. EMC Labs is accredited by AIHA-LAP to perform paint, dust, soil and airborne dust lead analysis. The related federal contract opportunity is a solicitation from the Department of the Air Force Materiel Command Test Center to remove 3 train carts.

View the file

Other files for this federal contract opportunity

Other files attached to Removal of 3 Train Carts, newest first.
File Type Posted
Combined Synopsis Solicitation - Train Carts Removal- Amendment 02.docx DOCX document
Combined Synopsis Solicitation - Train Carts Removal- Amendment 03.docx DOCX document
Combined Synopsis Solicitation - Train Carts Removal- Amendment 01.docx DOCX document
261093 coc lab.pdf PDF
274625 PLM 6004 Caboose 2022.pdf PDF
L87750 6004 2021.pdf PDF
L91885 coc lab.pdf PDF
277200 PLM train interior 2022.pdf PDF
274631 coc lab.pdf PDF
L91882 coc Caboose.pdf PDF
274631 6004 Bulk Sample Form 14 June 2022.xlsx XLSX spreadsheet
274631 PLM 6004 Train Cars 2022.pdf PDF
List of Train Carts Asbestos and Lead Reports (24 documents).PNG PNG image
274625 coc lab.pdf PDF
274631 6004 Bulk Sample Form 14 June 2022.pdf PDF
269949 PLM 6004 window blind.pdf PDF
277200 coc lab.pdf PDF
277199 coc lab.pdf PDF
6004.pdf PDF
L91885 6004 Train Cars 2022.pdf PDF
261093 PLM.pdf PDF
L87750 coc lab.pdf PDF
277199 PLM_train exterior all 3 2022.pdf PDF
Train Carts Removal Site Visit - Questions and Answers Final.pdf PDF
274631 acm sample map corrected.pdf PDF
L91882 Lead 6004 Caboose 2022.pdf PDF
261093 PLM 6004 Interior Exterior 2021.pdf PDF
269949 coc lab.pdf PDF
Train Carts Photos.pdf PDF
Remove 3 Trains SOW.pdf PDF
Solicitation Model Contract - FA930123Q0013.pdf PDF
SAM_Kern County_Wage Determination_122722.pdf PDF
Show all 32

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

EMC LABS, INC.

9830 South 51st Street, Suite B-109 / PHOENIX, ARIZONA 85044 / 480-940-5294 or 800-362-3373 / FAX 480-893-1726 emclab@emclabs.com

ANALYST: QA COORDINATOR:

Jason Thompson Kurt Kettler

Ver. 11/30/08 Rev. 7/15/19

LEAD (Pb) IN PAINT CHIP SAMPLES

EMC SOP METHOD #L01/1 EPA SW-846 METHOD 7420

EMC LAB #: L87750 DATE RECEIVED: 09/17/21

CLIENT: Edwards AFB REPORT DATE: 09/20/21

DATE OF ANALYSIS: 09/20/21

CLIENT ADDRESS: 412 CES/CEOER

225 N. Rosamond Blvd.

Edwards AFB, CA 93524

P.O. NO.:

PROJECT NAME: Samples taken at Bldg. 6004 PROJECT NO.:

EMC #

L87750-

SAMPLE

DATE /21

CLIENT

SAMPLE #

DESCRIPTION

REPORTING

LIMIT

(%Pb by weight)

%Pb BY

WEIGHT

1 09/13 6004-CE-1L Interior Paint 1.0 16.6^^

2 09/13 6004-CE-2L Interior Paint 0.010 0.336

3 09/13 6004-CE-3L Interior Paint 0.010 0.470

4 09/13 6004-CE-4L Exterior Paint 0.10 9.45^

5 09/13 6004-CE-5L Interior Paint 0.010 0.297 ^ = Dilution Factor Changed * = Excessive Substrate May Bias Sample Results BRL = Below Reportable Limits # = Very Small Amount Of Sample Submitted, May Affect Result

This report applies to the standards or procedures identified and to the samples tested only. The test results are not necessarily indicative or representative of the qualities of the lot from which the sample was taken or of apparently identical or similar products, nor do they represent an ongoing quality assurance program unless so noted. Unless otherwise noted, all quality control analyses for the samples noted above were within acceptable limits.

Where it is noted that a sample with excessive substrate was submitted for laboratory analysis, such analysis may be biased. The lead content of such sample may, in actuality, be greater than reported. EMC makes no warranty, express or implied, as to the accuracy of the analysis of samples noted to have been submitted with excessive substrate. Resampling is recommended in such situations to verify original laboratory results. EMC Labs, Inc. (ID 101586) is accredited by the AIHA Laboratory Accreditation Programs, LLC (AIHA-LAP, LLC) in the Environmental Lead accreditation program(s) for Paint, Settled Dust by Wipe, Soil and Airborne Dust Fields of Testing as documented by the Scope of Accreditation Certificate and associated Scope. AIHA-LAP, LLC accreditation complies with the ISO/IEC Standard 17025:2005. requirements.

These reports are for the exclusive use of the addressed client and are rendered upon the condition that they will not be reproduced wholly or in part for advertising or other purposes over our signature or in connection with our name without special written permission. Samples not destroyed in testing are retained a maximum of sixty (60) days.

File details come from the government source that posted it. Updated .