2_FA9101-19-R-2001,_Offer_Information.docx
DOCX document 39 KB Posted
- Attached to
- Concrete Target Fabrication Federal contract opportunity
- Solicitation number
- FA9101-19-R-2001
About this file
Offer Information
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Atch_09,_11,000_PSI_HPC_Recipe.pdf | ||
| FA9101-19-R-2001_QnA.pdf | ||
| Atch_01,_Requirements_Docment.pdf | ||
| Atch_06,_Finished_Target_Sample.pdf | ||
| Atch_03,_Holloman_Specific_Language.pdf | ||
| Atch_02,_FAR,_DFARS,_AFFARS_Prov_and_Clauses.pdf | ||
| Atch_04,_Evaluation_Plan.pdf | ||
| Atch_07,_HAFB_Site_Visit_eVAR.PDF | ||
| Atch_08,_HAFB_Site_Visit_Background_Consent.pdf | ||
| 1_FA9101-19-R-2001,_Combined_Synopsis_Solicitation.pdf | ||
| Atch_01,_Requirements_Docment.pdf | ||
| Atch_05,_Engineering_Drawing_Package.pdf |
Show all 12
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
FA9101-19-R-2001, Concrete Target Fabrication
By submitting this offer, the offeror acknowledges receipt of all attachments, amendments, and changes for this RFP.
Offeror’s Information
Company
Address
CAGE
DUNS
Federal Tax ID
POC
Phone / Fax
DELIVERY DATE:
The contractor shall deliver all items in accordance with the dates provided under each delivery order.
This performance period is |_| mandatory, |_| negotiable, |X| not applicable at this time.
NOTE: If the “negotiable” block is checked, please complete the following if you disagree with aforementioned performance period:
|_| Request performance period be changed to:
PAYMENT TERMS:
The Government shall consider your “DISCOUNT TERMS” to be NET 30 unless following block is marked and filled-in completely:
|_| Use the following DISCOUNT TERMS for this contract:
days; Net 30
ADDITIONAL INFORMATION (for Offeror Use):
{Insert Name}
DATE
{Insert Title}
| CLIN |
| DESCRIPTION |
| QTY (EACH) |
| UNIT |
PRICE
TOTAL
PRICE
BASIC PERIOD (Date of award – 12 months)
| 0001 |
| Standard Concrete Target |
18 ft. x 18 ft. x 6 ft., 5,000 PSI
| 0002 |
| Standard Concrete Target |
18 ft. x 18 ft. x 6 ft., 11,000 PSI
| 0003 |
| Standard Concrete Target |
18 ft. x 18 ft. x 6 ft., 11,000 PSI w/ High performance concrete
| 0004 |
| Standard Concrete Target |
22 ft. x 22 ft. x 1 ft., 5,000 PSI
| 0005 |
| Standard Concrete Target |
22 ft. x 22 ft. x 1 ft., 11,000 PSI
| 0006 |
| Standard Concrete Target |
22 ft. x 22 ft. x 1 ft., 11,000 PSI w/
| 0007 |
| Standard Concrete Target |
22 ft. x 22 ft. x 4 ft., 5,000 PSI
| 0008 |
| Standard Concrete Target |
22 ft. x 22 ft. x 4 ft., 11,000 PSI
| 0009 |
| Standard Concrete Target |
22 ft. x 22 ft. x 4 ft., 11,000 PSI w/
| 0010 |
| Non-standard Concrete Target |
Average size
| 0011 |
| Non-standard Concrete Target |
Extra Large (XL) size
| 0012 |
| Core Density Test (per event)* |
| 29 |
| 0013 |
| Lifting Lugs, Standard 1 |
| 10 |
| 0014 |
| Lifting Lugs, Standard 2 |
| 2 |
OPTION 1 (2 Years)
| 1001 |
| Standard Concrete Target |
| 1002 |
| Standard Concrete Target |
| 1003 |
| Standard Concrete Target |
18 ft. x 18 ft. x 6 ft., 11,000 PSI w/
| 1004 |
| Standard Concrete Target |
| 1005 |
| Standard Concrete Target |
| 1006 |
| Standard Concrete Target |
22 ft. x 22 ft. x 1 ft., 11,000 PSI w/
| 1007 |
| Standard Concrete Target |
| 1008 |
| Standard Concrete Target |
| 1009 |
| Standard Concrete Target |
22 ft. x 22 ft. x 4 ft., 11,000 PSI w/
| 1010 |
| Non-standard Concrete Target |
| 1011 |
| Non-standard Concrete Target |
| 1012 |
| Core Density Test (per event)* |
| 42 |
| 1013 |
| Lifting Lugs, Standard 1 |
| 10 |
| 1014 |
| Lifting Lugs, Standard 2 |
| 2 |
OPTION 2 (2 Years)
| 2001 |
| Standard Concrete Target |
| 2002 |
| Standard Concrete Target |
| 2003 |
| Standard Concrete Target |
18 ft. x 18 ft. x 6 ft., 11,000 PSI w/
| 2004 |
| Standard Concrete Target |
| 2005 |
| Standard Concrete Target |
| 2006 |
| Standard Concrete Target |
22 ft. x 22 ft. x 1 ft., 11,000 PSI w/
| 2007 |
| Standard Concrete Target |
| 2008 |
| Standard Concrete Target |
| 2009 |
| Standard Concrete Target |
22 ft. x 22 ft. x 4 ft., 11,000 PSI w/
| 2010 |
| Non-standard Concrete Target |
| 2011 |
| Non-standard Concrete Target |
| 2012 |
| Core Density Test (per event)* |
| 42 |
| 2013 |
| Lifting Lugs, Standard 1 |
| 10 |
| 2014 |
| Lifting Lugs, Standard 2 |
| 2 |
TOTAL EVALUATED PRICE:
File details come from the government source that posted it.