Attachment 1 Pricing Table Altus AFB 14 Jul 09.xlsx
XLSX spreadsheet 185 KB Posted
- Solicitation number
- FA8773-09-R-0002
About this file
Pricing Table - revised 14 Jul 09
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Attachment 2 PWS Altus AFB 14 Jul 09.pdf | ||
| Altus Solicitation Q A.pdf | ||
| FA8773-09-R-0002 Amend 0003.pdf | ||
| Solicitation Amendment 0002.pdf | ||
| Altus Conformed Contract 03D0003.pdf | ||
| Pre-Proposal Conf Signin and Agenda.pdf | ||
| Altus Synopsis Q A.doc | DOC document | |
| FA8773-09-R-0002-01 Altus RFP Amend 01.pdf | ||
| Attachment 3 EIPS 4 Jun 09.docx | DOCX document | |
| Performance Plan Altus - 16 Jun 09.docx | DOCX document | |
| Attachment 1 Pricing Table Altus AFB 5 Jun 09.xlsx | XLSX spreadsheet | |
| Attachment 2 PWS Altus AFB 16 Jun 09.docx | DOCX document | |
| RFP Cvr Ltr-Altus.doc | DOC document | |
| FA8773-09-R-0002 Altus RFP.pdf |
Show all 14
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Summary & CLIN X001
| Altus AFB OK | |||||||||||||||||||||
| FA8773-09-R-0002 | See Solicitation/Contract Section B and EIPS for Complete Descriptions | ||||||||||||||||||||
| 14-Jul-09 | |||||||||||||||||||||
| CLIN / SLIN # | DESCRIPTION | EST QTY FOR BASE PERIOD | BASE PERIOD (CLIN X=0) FY10 | EST QTY FOR OPT. 1 | OPTION PERIOD 1 (CLIN X=1) FY11 | EST QTY FOR OPT. 2 | OPTION PERIOD 2 (CLIN X=2) FY12 | EST QTY FOR OPT. 3 | OPTION PERIOD 3 (CLIN X=3) FY13 | EST QTY FOR OPT. 4 | OPTION PERIOD 4 (CLIN X=4) FY14 | ||||||||||
| UNIT PRICE | TOTAL PRICE | UNIT PRICE | TOTAL PRICE | UNIT PRICE | TOTAL PRICE | TOTAL PRICE | UNIT PRICE | TOTAL PRICE | |||||||||||||
| X001 | Operation & Maintenance (O&M) | ||||||||||||||||||||
| X001AA | O&M Base BTS | 12 | MO | $0.00 | 12 | MO | $0.00 | 12 | MO | $0.00 | 12 | MO | $0.00 | 12 | MO | $0.00 | |||||
| X001AB | O&M Base LMR | 12 | MO | $0.00 | 12 | MO | $0.00 | 12 | MO | $0.00 | 12 | MO | $0.00 | 12 | MO | $0.00 | |||||
| X001AC | RESERVED | 12 | MO | $0.00 | 12 | MO | $0.00 | 12 | MO | $0.00 | 12 | MO | $0.00 | 12 | MO | $0.00 | |||||
| X001AD | RESERVED | 12 | MO | $0.00 | 12 | MO | $0.00 | 12 | MO | $0.00 | 12 | MO | $0.00 | 12 | MO | $0.00 | |||||
| X002 | RESERVED | ||||||||||||||||||||
| X003 | Other Services | ||||||||||||||||||||
| X003AA | Locate & Mark Cable Above Qty specified in PWS 1.3.7 | 75000 | FT | $0.00 | 75000 | FT | $0.00 | 75000 | FT | $0.00 | 75000 | FT | $0.00 | 75000 | FT | $0.00 | |||||
| X003AB | Manhole & Handhole Maintenance Inspections (PWS 1.4.9.1) | 10 | EA | $0.00 | 10 | EA | $0.00 | 10 | EA | $0.00 | 10 | EA | $0.00 | 10 | EA | $0.00 | |||||
| X003AC | Distribution Pedestal Inspections (PWS 1.4.9.3) | 10 | EA | $0.00 | 10 | EA | $0.00 | 10 | EA | $0.00 | 10 | EA | $0.00 | 10 | EA | $0.00 | |||||
| X003AD | Building Entrance Terminal Inspections (PWS 1.4.9.2) | 10 | EA | $0.00 | 10 | EA | $0.00 | 10 | EA | $0.00 | 10 | EA | $0.00 | 10 | EA | $0.00 | |||||
| X004 | Purchase - Identified by Product ID and "A." | $0.00 | $0.00 | $0.00 | $0.00 | $0.00 | |||||||||||||||
| X005 | Installation & Services - Identified by Product ID and "B" | $0.00 | $0.00 | $0.00 | $0.00 | $0.00 | |||||||||||||||
| X006 | Removal - Identified by Product ID and "C" | $0.00 | $0.00 | $0.00 | $0.00 | $0.00 | |||||||||||||||
| X007 | Relocate - Identified by Product ID and "D" | $0.00 | $0.00 | $0.00 | $0.00 | $0.00 | |||||||||||||||
| X008 | GPS Data Collect Services (See SLINs under "C&D" workbook tab and Section B of Contract) | $0.00 | $0.00 | $0.00 | $0.00 | $0.00 | |||||||||||||||
| X009 | Labor Hours (See SLINs under "C&D" workbook tab & Section B of Contract). | $0.00 | $0.00 | $0.00 | $0.00 | $0.00 | |||||||||||||||
| X010 | Material. Quantity and U/I are "1 LS; Dollar amount is Estimated" (Material Factor included in Quantity Column for this CLIN, includes rate to provide material to destination (G&A, Profit, etc (excludes only taxes and shipping rates)) | 10,000.00 |
Pamela.McGowen: Pamela.McGowen:
| EACH BASE SHOULD REVIEW T&M USAGE and INPUT CLIN X010 Average here, not use this #. | 10,000.00 | 10,000.00 | 10,000.00 | 10,000.00 | 10,000.00 | 10,000.00 | 10,000.00 | 10,000.00 | 10,000.00 | |||||||
| TOTAL OF CLINS X001 THROUGH X010: | EST: | $10,000.00 | EST: | $10,000.00 | EST: | $10,000.00 | EST: | $10,000.00 | EST: | $10,000.00 | ||||||
| GRAND TOTAL (ALL YEARS): | NTE: | $50,000.00 | ||||||||||||||
| TOTAL EVALUATED PRICE (IAW Section M of RFP): | $10,000.00 | $10,000.00 | $10,000.00 | $10,000.00 | $10,000.00 | |||||||||||
| GRAND TOTAL EVALUATED PRICE (ALL YEARS): | $50,000.00 | |||||||||||||||
| NOTE: If awarded a contract for this effort, the successful contractor agrees to the release of prices in response to Freedom of Information Act (FOIA) requests and for publication electronically to include, but not limited to, the Federal Business Opportunites Web site. |
&"Times New Roman,Regular"&12PRICING TABLE
&"Times New Roman,Regular"Attachment 1 &"Times New Roman,Regular"&P of &N &"Times New Roman,Regular"&A
A & B (CLINs X004-5)
| Altus AFB OK | |||||||||||||||
| FA8773-09-R-0002 | |||||||||||||||
| 14-Jul-09 | |||||||||||||||
| BASE PERIOD | OPTION PERIOD 1 | OPTION PERIOD 2 | OPTION PERIOD 3 | OPTION PERIOD 4 | |||||||||||
| EST PURCHASE QTY | EST INSTALL QTY | PURCHASE PRICE | INSTALL PRICE | PURCHASE PRICE | INSTALL PRICE | PURCHASE PRICE | INSTALL PRICE | PURCHASE PRICE | INSTALL PRICE | PURCHASE PRICE | INSTALL PRICE | ||||
| Product ID | DESCRIPTION | A | B | A | B | A | B | A | B | A | B | A | B | ||
| GENERIC EQUIPMENT LIST | |||||||||||||||
| CUSTOMER PREMISE EQUIPMENT | |||||||||||||||
| TELEPHONE STATIONS | |||||||||||||||
| 3005 | Basic Telephone | 25 | EA | 200 | EA | ||||||||||
| 3006 | Basic Telephone, Non-dial | 2 | EA | 2 | EA | ||||||||||
| 3007 | Basic Telephone, Message Waiting Lamp | 2 | EA | 2 | EA | ||||||||||
| 3008 | Basic Telephone, Message Waiting Lamp with Additional Data Jack (RJ-11C) | 3 | EA | 3 | EA | ||||||||||
| 3009 | Basic Telephone, Speakerphone, Message Waiting Lamp | 3 | EA | 3 | EA | ||||||||||
| 3010 | Basic Telephone, Speakerphone, 10-Number Autodial | 10 | EA | 10 | EA | ||||||||||
| 3011 | Basic Telephone, Speakerphone, 30-Number Autodial | 5 | EA | 5 | EA | ||||||||||
| 3012 | Two-Line Telephone | 5 | EA | 5 | EA | ||||||||||
| 3013 | Two-Line Telephone, Speakerphone, Message Waiting Lamp | 5 | EA | 5 | EA | ||||||||||
| 3014 | Outdoor Telephone | 10 | EA | 10 | EA | ||||||||||
| 3015 | Hazardous Area / Explosion Proof Telephone | 2 | EA | 2 | EA | ||||||||||
| 3017 | Cordless Phones W/Display 2.4GHz (Panasonic or Tosiba) | 5 | EA | 5 | EA | ||||||||||
| 3018 | Wall Phone | 15 | EA | 15 | EA | ||||||||||
| 3020 | Basic Telephone Elevator-mount | 2 | EA | 2 | EA | ||||||||||
| 3021 | Basic Telephone, Speakerphone, 15-Number Autodial | 2 | EA | 2 | EA | ||||||||||
| 4270 | Basic Telephone, Speakerphone, 20-Number Autodial | 2 | EA | 2 | EA | ||||||||||
| 3022 | Two Line Telephone Message Waiting Lamp | 2 | EA | 2 | EA | ||||||||||
| 4271 | Two Line Telephone, Speakerphone | 2 | EA | 2 | EA | ||||||||||
| UNIVERSAL KEY SYSTEM SETS | |||||||||||||||
| 3042 | 10-Button Key Telephone w/ Integrated Speakerphone | EA | 5 | EA | |||||||||||
| 3046 | 30-Button Key System Telephone W/ Integrated Speakerphone | EA | 5 | EA | |||||||||||
| 3047 | 30-Button Key Telephone w/ Display and Integrated Speakerphone | EA | 5 | EA | |||||||||||
| ADJUNCTS and EXTERNAL SIGNALING DEVICES | |||||||||||||||
| 3061 | Speakerphone Attachment | 10 | EA | 10 | EA | ||||||||||
| 3062 | Recessed Round Ceiling Speaker, up to 1/4 W w/ Volume Control | 10 | EA | 10 | EA | ||||||||||
| 3063 | Speaker for dropped/Suspended Ceiling, up to 1/4 W w/ Volume Control | 10 | EA | 10 | EA | ||||||||||
| 3064 | Speaker for Warehouse, indoor | 2 | EA | 2 | EA | ||||||||||
| 3066 | Doorphone Set, including doorphone speaker w/ volume control and adapter/control unit | 2 | EA | 2 | EA | ||||||||||
| 3067 | Ringing Generator for Ringer (Required if direct line is not available) | 5 | EA | 5 | EA | ||||||||||
| 3068 | Tel-Strobe Lamp - Indoor | 2 | EA | 2 | EA | ||||||||||
| 3069 | Tel-Strobe Lamp - Outdoor | 2 | EA | 2 | EA | ||||||||||
| 3070 | Speaker for Warehouse, outdoor, water/weather resistant | 2 | EA | 2 | EA | ||||||||||
| 3071 | Horn Loudspeaker, 1/4 to 1 Watt w/ Volume Control, Weather-Proof | 2 | EA | 2 | EA | ||||||||||
| 3072 | Horn Loudspeaker, 1/4 to 15 Watt w/ Volume Control, Weather-Proof | 2 | EA | 2 | EA | ||||||||||
| 3073 | Horn Loudspeaker, 1/4 to 30 Watt w/ Volume Control, Weather-Proof | 2 | EA | 2 | EA | ||||||||||
| 3074 | Horn Loudspeaker, 1/4 to 40 Watt w/ Volume Control, Explosion-Proof | 2 | EA | 2 | EA | ||||||||||
| 3075 | External Bell Ringer for Single Line | 2 | EA | 2 | EA | ||||||||||
| 3076 | External Loud Gong Ringer for Single Line | 1 | EA | 1 | EA | ||||||||||
| 3077 | Indoor Bell Ringer | 5 | EA | 5 | EA | ||||||||||
| 3078 | Indoor Chime Ringer, up to 1,000 sq ft | 1 | EA | 1 | EA | ||||||||||
| 3079 | Indoor Electronic Tone Ringer | 1 | EA | 1 | EA | ||||||||||
| 3080 | Indoor Buzzer | 3 | EA | 3 | EA | ||||||||||
| 3081 | Indoor Horn | 2 | EA | 2 | EA | ||||||||||
| 3082 | Loud Outdoor Bell Ringer, Weather-Proof | 5 | EA | 5 | EA | ||||||||||
| 3083 | 2 Way Manual Switch (Voice/Data, Data/Data, Fax /Data) | 1 | EA | 1 | JB | ||||||||||
| 3085 | Ringer Isolator | 1 | EA | 1 | EA | ||||||||||
| HANDSETS, HEADSETS, and CORDS | |||||||||||||||
| 3089 | Universal Shoulder Rest, Handset attachable | 3 | EA | ||||||||||||
| 3090 | Handset, Basic | 5 | EA | ||||||||||||
| 3092 | Handset w/ Amplifier and Volume Control | 10 | EA | ||||||||||||
| 3093 | Handset w/ Speech Amplifier and Volume Control | 10 | EA | ||||||||||||
| 3094 | Push-To-Talk Handset | 15 | EA | ||||||||||||
| 3095 | Push-to-Listen Handset | 5 | EA | ||||||||||||
| 3096 | Handset Confidencer | 2 | EA | ||||||||||||
| 3097 | Single Muff Headset Package | 2 | EA | ||||||||||||
| 3098 | Dual Muff Headset Package | 1 | EA | ||||||||||||
| 3099 | Headset Cord, 8 FT | 10 | EA | ||||||||||||
| 3100 | Headset Cord, 15 Ft | 15 | EA | ||||||||||||
| 3101 | Headset Cord, 30 Ft | 30 | EA | ||||||||||||
| 3102 | Telephone Handset Cord, 9 ft, Modular Plug at Both Ends | 10 | EA | ||||||||||||
| 3103 | Telephone Handset Cord, 14 ft, Modular Plug at Both Ends | 15 | EA | ||||||||||||
| 3104 | Telephone Handset Cord, 25 ft, Modular Plug at Both Ends | 25 | EA | ||||||||||||
| 3105 | Telephone Handset Cord, 30 ft, Modular Plug at Both Ends | 25 | EA | ||||||||||||
| 3106 | Straight Telephone Line Cord, 6 ft, 4-6 Conductor, Plug at Both Ends | 15 | EA | ||||||||||||
| 3107 | Straight Telephone Line Cord, 6 ft, 4-6 Conductor, Plug to Spade Tip | 15 | EA | 15 | EA | ||||||||||
| 3108 | Straight Telephone Line Cord, 6 ft, 6-8 Conductor, Plug at Both Ends | 15 | EA | ||||||||||||
| 3109 | Straight Telephone Line Cord, 6 ft, 6-8 Conductor, Plug to Spade Tip | 15 | EA | 15 | EA | ||||||||||
| 3110 | Straight Telephone Line Cord, 14 ft, 6-8 Conductor, Plug at Both Ends | 15 | EA | ||||||||||||
| 3111 | Straight Telephone Line Cord, 14 ft, 6-8 Conductor, Plug to Spade Tip | 15 | EA | 15 | EA | ||||||||||
| 3112 | Straight Telephone Line Cord, 12 ft, 6-8 Conductor, Plug at Both Ends | 15 | EA | ||||||||||||
| 3113 | Straight Telephone Line Cord, 12 ft, 6-8 Conductor, Plug to Spade Tip | 15 | EA | 15 | EA | ||||||||||
| 3114 | Straight Telephone Line Cord, 25 ft, 4-6 Conductor, Plug at Both Ends | 20 | EA | ||||||||||||
| 3115 | Straight Telephone Line Cord, 25 ft, 4-6 Conductor, Plug to Spade Tip | 25 | EA | 25 | EA | ||||||||||
| 3116 | Straight Telephone Line Cord, 25 ft, 6-8 Conductor, Plug at Both Ends | 25 | EA | ||||||||||||
| 3117 | Straight Telephone Line Cord, 25 ft, 6-8 Conductor, Plug to Spade Tip | 25 | EA | 25 | EA | ||||||||||
| INSIDE PLANT EQUIPMENT | |||||||||||||||
| DATA SERVICE UNIT / CHANNEL SERVICE UNIT | |||||||||||||||
| 3131 | Dial-up Modem up to 56K | 1 | EA | 1 | EA | ||||||||||
| 3132 | Long-Haul Modem 56K/33.6/28.8/14.4/9600/4800Kbp 2/4, wire | 2 | EA | 2 | EA | ||||||||||
| 3133 | Long-Haul Modem With/two Channel Mux. 56K/33.6/28.8/14.4/9600/4800Kbp 2/4, wire | 2 | EA | 2 | EA | ||||||||||
| 3134 | Pairagain T-1 | 4 | EA | 4 | EA | ||||||||||
| 3137 | Office Repeater Mounting Shelf with Power Supply | 2 | EA | 2 | JB | ||||||||||
| TERMINAL BLOCK CONNECTORS | |||||||||||||||
| 3166 | Amphenol 50-pin connector, Male | 20 | EA | 20 | EA | ||||||||||
| 3167 | Amphenol 50-pin connector, Female | 20 | EA | 20 | EA | ||||||||||
| 3168 | Amphenol 64-pin connector, Male | 2 | EA | 2 | EA | ||||||||||
| 3169 | Amphenol 64-pin connector, Female | 2 | EA | 2 | EA | ||||||||||
| HORIZONTAL TERMINAL BLOCKS | |||||||||||||||
| 3173 | Horizontal Block w/ wire wrap, 6x24 | 3 | EA | 3 | EA | ||||||||||
| 3174 | Horizontal Block w/ wire wrap/50-pin connectors, 6x24 | 3 | EA | 3 | EA | ||||||||||
| 3175 | Horizontal Block w/ wire wrap, 6x25 | 3 | EA | 3 | EA | ||||||||||
| 3176 | Horizontal Block w/ wire wrap/50-pin connectors, 6x25 | 3 | EA | 3 | EA | ||||||||||
| 3177 | Horizontal Block w/ wire wrap, 8x24 | 3 | EA | 3 | EA | ||||||||||
| 3178 | Horizontal Block w/ wire wrap/50-pin connector, 8x24 | 1 | EA | 1 | EA | ||||||||||
| MISCELLANEOUS MOUNTING EQUIPMENT | |||||||||||||||
| 3204 | Cable Rack, 10ft X 6 in, remote location | 10 | EA | 10 | EA | ||||||||||
| 3205 | Cable Rack, 10ft X 12 in, Central Office | 10 | EA | 10 | EA | ||||||||||
| 3206 | Ground Bus Bar, Copper, nominal 2in X 10in, remote location | 2 | EA | 2 | EA | ||||||||||
| 3207 | DSX-1 Cross Connect Panel, 28 port with LED indicator, Central Office | 1 | EA | 1 | EA | ||||||||||
| 3208 | DSX-1 Cross Connect Mounting Panel equipped with a 4 port with LED indicator modular insert, remote location | 1 | EA | 1 | EA | ||||||||||
| 3209 | DSX-1 Cross Connect Insert for Mounting Panel, 4 port with LED indicator modular insert, remote location | 1 | EA | 1 | EA | ||||||||||
| 4403 | Wallmount Cabinet 24"H x 26"D, lockable, swing out for rear access | 1 | EA | 1 | EA | ||||||||||
| 4404 | Ultra Wallmount Rack 24.25"H x 25"D, lockable, swing out for rear access | 1 | EA | 1 | EA | ||||||||||
| 4405 | Wallmount Frame 24"H x 25" D | 1 | EA | 1 | EA | ||||||||||
| 4406 | Telephone Relay Rack | 1 | EA | 1 | EA | ||||||||||
| 6152 | Horizontal Cable Management For Two Post 19" Rack | 50 | EA | 50 | EA | ||||||||||
| 6153 | Vertical Cable Management For Two Post 19" Rack 4" Depth | 20 | EA | 20 | EA | ||||||||||
| 6154 | Vertical Cable Management For Two Post 19" Rack 8" Depth | 20 | EA | 20 | EA | ||||||||||
| 6155 | 'Wallmount Cabinet 24"H x 8"D, lockable, swing out for rear access (Mid Atlantic Part Number HDR 4 with Fan Kit ($350.00) | 10 | EA | 10 | EA | ||||||||||
| BUILDING INSIDE STRUCTURE CABLE AND DISTRIBUTION | |||||||||||||||
| HOUSE WIRING and OUTLETs | |||||||||||||||
| OUTLETS/JACKS | |||||||||||||||
| 3218 | Single Outlet Box - Flush Mount | 100 | EA | 100 | EA | ||||||||||
| 3219 | Single Outlet Box - Surface Mount | 50 | EA | 50 | EA | ||||||||||
| 3220 | Duplex Outlet Box - Flush Mount | 1,500 | EA | 1500 | EA | ||||||||||
| 3221 | Duplex Outlet Box - Surface Mount | 300 | EA | 300 | EA | ||||||||||
| 3222 | Quad Outlet Box - Flush Mount | 100 | EA | 100 | EA | ||||||||||
| 3223 | Quad Outlet Box - Surface Mount | 25 | EA | 25 | EA | ||||||||||
| 3224 | Sixplex Outlet Box - Flush Mount | 5 | EA | 5 | EA | ||||||||||
| 3225 | Sixplex Outlet Box - Surface Mount | 2 | EA | 2 | EA | ||||||||||
| 3226 | Eightplex Outlet Box - Flush Mount | 2 | EA | 2 | EA | ||||||||||
| 3227 | Eightplex Outlet Box - Surface Mount | 2 | EA | 2 | EA | ||||||||||
| 3228 | Voice Jack | 50 | EA | 50 | EA | ||||||||||
| 3229 | Cat 3 Jack | 100 | EA | 100 | EA | ||||||||||
| 3230 | Cat 5 Jack | 300 | EA | 300 | EA | ||||||||||
| 3231 | Cat 5e Jack | 300 | EA | 300 | EA | ||||||||||
| 3232 | Cat 6 Jack | 1,500 | EA | 1500 | EA | ||||||||||
| Fiber Optic Jacks | |||||||||||||||
| 3244 | Fiber Optic Connector - SC, SM | 500 | EA | 500 | EA | ||||||||||
| 3246 | Fiber Optic Connector - SC, MM | 72 | EA | 72 | EA | ||||||||||
| INSIDE CABLE (/Ft. Length) | |||||||||||||||
| 3258 | Plenum Cat III - 4 PR | 10,000 | FT | 10000 | FT | ||||||||||
| 3259 | Plenum Cat 5 - 4 PR | 30,000 | FT | 30000 | FT | ||||||||||
| 3261 | Plenum Cat 6 - 4 PR | 450,000 | FT | 450000 | FT | ||||||||||
| Plenum Cat 5 - 25 PR CABLE ASSY. (/Ft. Length) | |||||||||||||||
| 3269 | 25 Pair Cat 6 Plenum | 3,000 | FT | 3000 | FT | ||||||||||
| Connector Block | |||||||||||||||
| 3281 | 25 Pair Station Connector Block | 25 | EA | 25 | EA | ||||||||||
| 3282 | 50 Pair Station Connector Block | 25 | EA | 25 | EA | ||||||||||
| Cat 5 Connector Block (Patch Panel) with RJ cross connect | |||||||||||||||
| 3287 | 12 Port | 10 | EA | 10 | JB | ||||||||||
| 3288 | 24 Port | 10 | EA | 10 | JB | ||||||||||
| 3289 | 48 Port | 10 | EA | 10 | JB | ||||||||||
| 3290 | 72 Port | 2 | EA | 2 | JB | ||||||||||
| 3291 | 96 port | 2 | EA | 2 | JB | ||||||||||
| Cat 5 Connector Block (Patch Panel) with 110 connector | |||||||||||||||
| 3297 | 12 Port | 10 | EA | 10 | JB | ||||||||||
| 3295 | 24 Port | 10 | EA | 10 | JB | ||||||||||
| 3298 | 36 port | 10 | EA | 10 | JB | ||||||||||
| 3296 | 48 Port | 50 | EA | 50 | JB | ||||||||||
| 3299 | 72 Port | 10 | EA | 10 | JB | ||||||||||
| 4276 | 96 port | 10 | EA | 10 | JB | ||||||||||
| Cat 5e Connector Block (Patch Panel) with 110 connector | |||||||||||||||
| 4287 | 12 Port | 2 | EA | 2 | JB | ||||||||||
| 4288 | 24 Port | 2 | EA | 2 | JB | ||||||||||
| 4289 | 36 port | 2 | EA | 2 | JB | ||||||||||
| 4290 | 48 Port | 2 | EA | 2 | JB | ||||||||||
| 4291 | 72 Port | 2 | EA | 2 | JB | ||||||||||
| 4292 | 96 port | 2 | EA | 2 | JB | ||||||||||
| Cat 6 Connector Block (Patch Panel) with RJ cross connect | |||||||||||||||
| 4296 | 24 Port | 10 | EA | 10 | JB | ||||||||||
| 4298 | 48 Port | 50 | EA | 50 | JB | ||||||||||
| Cat 6 Connector Block (Patch Panel) with 110 connector | |||||||||||||||
| 4304 | 24 Port | 50 | EA | 50 | JB | ||||||||||
| 4306 | 48 Port | 50 | EA | 50 | JB | ||||||||||
| SURFACE-MOUNT RACEWAY | |||||||||||||||
| 3301 | Non-Metallic Raceway | 2,500 | FT | 2500 | FT | ||||||||||
| 3302 | Non-Metallic Box | 4 | EA | 4 | EA | ||||||||||
| BUILDING STATION TERMINAL BLOCKS | |||||||||||||||
| 3304 | 6-pair punch-down | 5 | EA | 5 | EA | ||||||||||
| 3305 | 12-pair punch-down | 5 | EA | 5 | EA | ||||||||||
| 3306 | 25-pair punch-down | 10 | EA | 10 | EA | ||||||||||
| 3307 | 50-pair punch-down | 50 | EA | 50 | EA | ||||||||||
| BUILDING DISTRIBUTION or RISER CABLES | |||||||||||||||
| 3311 | 6 Pair, 24 AWG | 150 | FT | 150 | FT | ||||||||||
| 3312 | 25 Pair, 24 AWG | 5,000 | FT | 5000 | FT | ||||||||||
| 3313 | 50 Pair, 24 AWG | 5,000 | FT | 5000 | FT | ||||||||||
| 3314 | 100 Pair, 24 AWG | 2,000 | FT | 2000 | FT | ||||||||||
| 3315 | 200 Pair, 24 AWG | 1,000 | FT | 1000 | FT | ||||||||||
| CENTRAL OFFICE FIELD/GRAY WIRE/TIP CABLES | |||||||||||||||
| 3323 | 25 Pair, 24 AWG | 200 | FT | 200 | FT | ||||||||||
| 3324 | 50 Pair, 24 AWG | 200 | FT | 200 | FT | ||||||||||
| FIBER OPTIC PATCH PANEL | |||||||||||||||
| 3328 | Fiber Optic Patch Panel (12 Fiber, w/o connectors) | 20 | EA | 20 | EA | ||||||||||
| 3329 | Fiber Optic Patch Panel (24 Fiber, w/o connectors) | 20 | EA | 10 | EA | ||||||||||
| 3330 | Fiber Optic Patch Panel (36 Fiber, w/o connectors) | 10 | EA | 10 | EA | ||||||||||
| 3331 | Fiber Optic Patch Panel (48 Fiber, w/o connectors) | 10 | EA | 10 | EA | ||||||||||
| 3332 | Fiber Optic Patch Panel (72 Fiber, w/o connectors) | 10 | EA | 10 | EA | ||||||||||
| 3333 | Fiber Optic Patch Panel (96 Fiber, w/o connectors) | 4 | EA | 4 | EA | ||||||||||
| 3334 | Fiber Optic Patch Panel (144 Fiber, w/o connectors) | 4 | EA | 4 | EA | ||||||||||
| 3335 | SC bulkhead connectors, SM | 500 | EA | 500 | EA | ||||||||||
| 3336 | SC bulkhead connector, MM | 24 | EA | 24 | EA | ||||||||||
| 3337 | ST bulkhead connectors, SM | 24 | EA | 24 | EA | ||||||||||
| 3338 | ST bulkhead connector, MM | 24 | EA | 24 | EA | ||||||||||
| 3339 | Patch Panel Cord Manager | 100 | EA | 100 | EA | ||||||||||
| FIBER OPTIC CABLE FOR INSIDE STRUCTURE INSTALLATION | |||||||||||||||
| 3346 | 6 Fiber Single Mode Cable | 200 | MR | 656 | FT | ||||||||||
| 3348 | 12 Fiber Single Mode Cable | 5,000 | MR | 16404 | FT | ||||||||||
| 3351 | 24 Fiber Single Mode Cable | 2,000 | MR | 6561 | FT | ||||||||||
| 3352 | 24 Fiber Multi-Mode Cable | 500 | MR | 1640 | FT | ||||||||||
| 3354 | 36 Fiber Single Mode Cable | 5,000 | MR | 16404 | FT | ||||||||||
| FIBER OPTIC PATCH CABLE ASSEMBLIES, SINGLE MODE, FROM PATCH PANEL TO PATCH PANEL | |||||||||||||||
| 3362 | SC-SC; Length 0.6 M | 24 | EA | 24 | EA | ||||||||||
| 3363 | SC-SC; Length 3M | 24 | EA | 24 | EA | ||||||||||
| 3364 | SC-SC; Length 5M | 24 | EA | 24 | EA | ||||||||||
| 3365 | SC-SC; Length 10M | 24 | EA | 24 | EA | ||||||||||
| 3366 | SC-SC; Length 20 M | 24 | EA | 24 | EA | ||||||||||
| FIBER OPTIC PATCH CABLE ASSEMBLIES, SINGLE MODE, FROM PATCH PANEL TO PATCH PANEL | |||||||||||||||
| 3398 | ST-ST; Length 0.6 M | 5 | EA | 5 | EA | ||||||||||
| 3399 | ST-ST; Length 3M | 5 | EA | 5 | EA | ||||||||||
| 3400 | ST-ST; Length 5M | 5 | EA | 5 | EA | ||||||||||
| 3401 | ST-ST; Length 10M | 5 | EA | 5 | EA | ||||||||||
| 3402 | ST-ST; Length 20 M | 5 | EA | 5 | EA | ||||||||||
| FIBER OPTIC CABLE ASSEMBLIES, SINGLE MODE, FROM PATCH PANEL TO PREMISE EQUIPMENT | |||||||||||||||
| 4311 | ST - SC Connectors (3 Ft) | 12 | EA | 12 | EA | ||||||||||
| 4312 | ST - SC Connectors (6 Ft) | 12 | EA | 12 | EA | ||||||||||
| 4313 | ST - SC Connectors (10 Ft) | 12 | EA | 12 | EA | ||||||||||
| 4314 | ST - SC Connectors (15 Ft) | 12 | EA | 12 | EA | ||||||||||
| 4315 | ST - SC Connectors (25 Ft) | 12 | EA | 12 | EA | ||||||||||
| 4316 | ST - SC Connectors (50 Ft) | 12 | EA | 12 | EA | ||||||||||
| 3424 | SC - SC Connectors (25 Ft) | 24 | EA | 24 | EA | ||||||||||
| 3425 | SC - SC Connectors (50Ft) | 24 | EA | 24 | EA | ||||||||||
| 3426 | SC - SC Connectors (75Ft) | 24 | EA | 24 | EA | ||||||||||
| 3427 | SC - SC Connectors (100Ft) | 24 | EA | 24 | EA | ||||||||||
| 3428 | SC - SC Connectors (150Ft) | 24 | EA | 24 | EA | ||||||||||
| FIBER OPTIC CABLE ASSEMBLIES, PLENUM, SINGLE MODE, FROM PATCH PANEL TO PREMISE EQUIPMENT | |||||||||||||||
| 3454 | SC - SC Connectors (25 Ft) | 40 | EA | 40 | EA | ||||||||||
| 3455 | SC - SC Connectors (50Ft) | 40 | EA | 40 | EA | ||||||||||
| 3456 | SC - SC Connectors (75Ft) | 40 | EA | 40 | EA | ||||||||||
| 3457 | SC - SC Connectors (100Ft) | 40 | EA | 40 | EA | ||||||||||
| 3458 | SC - SC Connectors (150Ft) | 40 | EA | 40 | EA | ||||||||||
| FIBER OPTIC CABLE ASSEMBLIES, PLENUM, MULTIMODE MODE, FROM PATCH PANEL TO PREMISE EQUIPMENT | |||||||||||||||
| 3469 | SC - SC Connectors (25 Ft) | 5 | EA | 5 | EA | ||||||||||
| 3470 | SC - SC Connectors (50Ft) | 5 | EA | 5 | EA | ||||||||||
| 3471 | SC - SC Connectors (75Ft) | 5 | EA | 5 | EA | ||||||||||
| OUTSIDE PLANT CABLE AND DISTRIBUTION | |||||||||||||||
| PROTECTED VERTICAL TERMINAL BLOCK COMPONENTS | |||||||||||||||
| 3484 | 100 pair vertical protector block, 8 1/2"H x 41/2"W, including protector modules | 2 | EA | 2 | EA | ||||||||||
| 3485 | 100 pair vertical protector block w/ ___' 24 AWG stub cable, 8 1/2"H x 41/2"W, excluding protector modules | 2 | EA | 2 | EA | ||||||||||
| 3486 | 3 Element Gas Tube Protector Module | 50 | EA | 50 | EA | ||||||||||
| 3488 | Line Grounding Module | 5 | EA | 5 | EA | ||||||||||
| SPLICING | |||||||||||||||
| Splicing Buried Metallic Cable: | |||||||||||||||
| 3494 | up to 25 pair | 2 | EA | 2 | EA | ||||||||||
| 3495 | 50 pair | 2 | EA | 2 | EA | ||||||||||
| 3496 | 75 pair | 1 | EA | 1 | EA | ||||||||||
| 3497 | 100 pair | 4 | EA | 4 | EA | ||||||||||
| 3498 | 150 pair | 1 | EA | 1 | EA | ||||||||||
| 3499 | 200 pair | 2 | EA | 2 | EA | ||||||||||
| 3500 | 300 pair | 1 | EA | 1 | EA | ||||||||||
| 3501 | 400 pair | 1 | EA | 1 | EA | ||||||||||
| 3502 | 600 pair | 1 | EA | 1 | EA | ||||||||||
| 3503 | 900 pair | 1 | EA | 1 | EA | ||||||||||
| 3504 | 1200 pair | 1 | EA | 1 | EA | ||||||||||
| 3505 | 1500 pair | 1 | EA | 1 | EA | ||||||||||
| 3506 | 1800 pair | 1 | EA | 1 | EA | ||||||||||
| 3507 | 2100 pair | 1 | EA | 1 | EA | ||||||||||
| 3508 | 2400 pair | 1 | EA | 1 | EA | ||||||||||
| Splicing for Underground Metallic Cable: | |||||||||||||||
| 3515 | up to 25 pair | 1 | EA | 1 | EA | ||||||||||
| 3516 | 50 pair | 1 | EA | 1 | EA | ||||||||||
| 3517 | 75 pair | 1 | EA | 1 | EA | ||||||||||
| 3518 | 100 pair | 2 | EA | 2 | EA | ||||||||||
| 3519 | 150 pair | 1 | EA | 1 | EA | ||||||||||
| 3520 | 200 pair | 2 | EA | 2 | EA | ||||||||||
| 3521 | 300 pair | 2 | EA | 2 | EA | ||||||||||
| 3522 | 400 pair | 2 | EA | 2 | EA | ||||||||||
| 3523 | 500 pair | 2 | EA | 2 | EA | ||||||||||
| 3524 | 600 pair | 2 | EA | 2 | EA | ||||||||||
| 3525 | 900 pair | 2 | EA | 2 | EA | ||||||||||
| 3526 | 1200 pair | 2 | EA | 2 | EA | ||||||||||
| 3527 | 1500 pair | 1 | EA | 1 | EA | ||||||||||
| 3528 | 1800 pair | 1 | EA | 1 | EA | ||||||||||
| 3529 | 2100 pair | 1 | EA | 1 | EA | ||||||||||
| 3530 | 2400 pair | 1 | EA | 1 | EA | ||||||||||
| Splicing for Buried Fiber Cable: | |||||||||||||||
| 3537 | 2 Fiber Strands, Fusion | 2 | EA | 2 | EA | ||||||||||
| 3538 | 4 Fiber Strands, Fusion | 2 | EA | 2 | EA | ||||||||||
| 3539 | 6 Fiber Strands, Fusion | 4 | EA | 4 | EA | ||||||||||
| 3540 | 12 Fiber Strands, Fusion | 5 | EA | 5 | EA | ||||||||||
| 3541 | 18 Fiber Strands, Fusion | 1 | EA | 1 | EA | ||||||||||
| 3542 | 24 Fiber Strands, Fusion | 4 | EA | 4 | EA | ||||||||||
| 3543 | 30 Fiber Strands, Fusion | 1 | EA | 1 | EA | ||||||||||
| 3544 | 36 Fiber Strands, Fusion | 4 | EA | 4 | EA | ||||||||||
| 3545 | 48 Fiber Strands, Fusion | 2 | EA | 2 | EA | ||||||||||
| 3546 | 72 Fiber Strands, Fusion | 1 | EA | 1 | EA | ||||||||||
| Splicing for Underground Fiber Cable: | |||||||||||||||
| 3551 | 2 Fiber Strands, Fusion | 2 | EA | 2 | EA | ||||||||||
| 3552 | 4 Fiber Strands, Fusion | 2 | EA | 2 | EA | ||||||||||
| 3553 | 6 Fiber Strands, Fusion | 5 | EA | 5 | EA | ||||||||||
| 3554 | 12 Fiber Strands, Fusion | 10 | EA | 10 | EA | ||||||||||
| 3555 | 18 Fiber Strands, Fusion | 1 | EA | 1 | EA | ||||||||||
| 3556 | 24 Fiber Strands, Fusion | 4 | EA | 4 | EA | ||||||||||
| 3557 | 30 Fiber Strands, Fusion | 1 | EA | 1 | EA | ||||||||||
| 3558 | 36 Fiber Strands, Fusion | 4 | EA | 4 | EA | ||||||||||
| 3559 | 48 Fiber Strands, Fusion | 2 | EA | 2 | EA | ||||||||||
| 3560 | 72 Fiber Strands, Fusion | 1 | EA | 1 | EA | ||||||||||
| METALLIC CABLE | |||||||||||||||
| Metallic Cable, PE 39, Unarmored (For installation into manhole/conduit): | |||||||||||||||
| 3567 | 6 Pair Cable, 19 Gauge | 100 | FT | ||||||||||||
| 3568 | 6 Pair Cable, 22 Gauge | 100 | FT | ||||||||||||
| 3569 | 6 Pair Cable, 24 Gauge | 100 | FT | ||||||||||||
| 3570 | 12 Pair Cable, 19 Gauge | 100 | FT | ||||||||||||
| 3572 | 12 Pair Cable, 24 Gauge | 500 | FT | ||||||||||||
| 3574 | 25 Pair Cable, 24 Gauge | 1,000 | FT | ||||||||||||
| 3576 | 50 Pair Cable, 24 Gauge | 1,000 | FT | ||||||||||||
| 3579 | 100 Pair Cable, 24 Gauge | 1,500 | FT | ||||||||||||
| 3581 | 150 Pair Cable, 24 Gauge | 300 | FT | ||||||||||||
| 3583 | 200 Pair Cable, 24 Gauge | 300 | FT | ||||||||||||
| 3585 | 300 Pair Cable, 24 Gauge | 300 | FT | ||||||||||||
| 3587 | 400 Pair Cable, 24 Gauge | 300 | FT | ||||||||||||
| 3588 | 600 Pair Cable, 24 Gauge | 250 | FT | ||||||||||||
| 3589 | 900 Pair Cable, 24 Gauge | 200 | FT | ||||||||||||
| 3590 | 1200 Pair Cable, 24 Gauge | 500 | FT | ||||||||||||
| 3591 | 1500 Pair Cable, 24 Gauge | 500 | FT | ||||||||||||
| 4345 | 1800 Pair Cable, 22 Gauge | 500 | FT | ||||||||||||
| 4346 | 1800 Pair Cable, 24 Gauge | 500 | FT | ||||||||||||
| Metallic Cable, PE 39, Armored, Gopher Resistant Tape (For direct buried installation): | |||||||||||||||
| 3604 | 6 Pair Cable, 24 Gauge | 600 | FT | ||||||||||||
| 3607 | 12 Pair Cable, 24 Gauge | 600 | FT | ||||||||||||
| 3609 | 25 Pair Cable, 24 Gauge | 1,000 | FT | ||||||||||||
| 3611 | 50 Pair Cable, 24 Gauge | 1,000 | FT | ||||||||||||
| 3613 | 100 Pair Cable, 24 Gauge | 2,000 | FT | ||||||||||||
| 3615 | 150 Pair Cable, 24 Gauge | 300 | FT | ||||||||||||
| 3617 | 200 Pair Cable, 24 Gauge | 300 | FT | ||||||||||||
| 3619 | 300 Pair Cable, 24 Gauge | 300 | FT | ||||||||||||
| 3621 | 400 Pair Cable, 24 Gauge | 400 | FT | ||||||||||||
| 3622 | 600 Pair Cable, 24 Gauge | 300 | FT | ||||||||||||
| 3623 | 900 Pair Cable, 24 Gauge | 300 | FT | ||||||||||||
| 3624 | 1200 Pair Cable, 24 Gauge | 300 | FT | ||||||||||||
| BUILDING ENTRANCE CABLES (Assembled from components) | |||||||||||||||
| 6 Pair Cable, 24 Gauge | |||||||||||||||
| 3635 | Transition Splice to 6 pair Building Cable | 1 | EA | 1 | EA | ||||||||||
| 3636 | 6 pair Protected Terminal Block equipped with Protector Gas Modules | 1 | EA | 1 | EA | ||||||||||
| 12 Pair Cable, 24 Gauge | |||||||||||||||
| 3668 | Transition Splice to 12 pair Building Cable | 2 | EA | 2 | JB | ||||||||||
| 3669 | 12 pair Protected Terminal Block equipped with Protector Gas Modules | 2 | EA | 2 | JB | ||||||||||
| 25 Pair Cable, 24 Gauge | |||||||||||||||
| 3639 | Transition Splice to 25 pair Building Cable | 5 | EA | 5 | EA | ||||||||||
| 3640 | 25 pair Protected Terminal Block equipped with Protector Gas Modules | 5 | EA | 5 | EA | ||||||||||
| 50 Pair Cable, 24 Gauge | |||||||||||||||
| 3642 | Transition Splice to 50 pair Building Cable | 5 | EA | 5 | EA | ||||||||||
| 3643 | 50 pair Protected Terminal Block equipped with Protector Gas Modules | 5 | EA | 5 | EA | ||||||||||
| 100 Pair Cable, 24 Gauge | |||||||||||||||
| 3645 | Transition Splice to 100 pair Building Cable | 5 | EA | 5 | EA | ||||||||||
| 3646 | 100 pair Protected Terminal Block equipped with Protector Gas Modules | 5 | EA | 5 | EA | ||||||||||
| 200 Pair Cable, 24 Gauge | |||||||||||||||
| 3648 | Vault Splice for 200 pair Building Cable | 1 | EA | 1 | EA | ||||||||||
| 3649 | Transition Splice to 200 pair Building Cable | 1 | EA | 1 | EA | ||||||||||
| 3650 | 200 pair Protected Terminal Block equipped with Protector Gas Modules | 1 | EA | 1 | EA | ||||||||||
| 300 Pair Cable, 24 Gauge | |||||||||||||||
| 3652 | Vault Splice for 300 pair Building Cable | 1 | EA | 1 | EA | ||||||||||
| 3653 | Transition Splice to 300 pair Building Cable | 1 | EA | 1 | EA | ||||||||||
| 3654 | 300 pair Protected Terminal Block equipped with Protector Gas Modules | 1 | EA | 1 | EA | ||||||||||
| 400 Pair Cable, 24 Gauge | |||||||||||||||
| 3656 | Vault Splice for 400 pair Building Cable | 1 | EA | 1 | EA | ||||||||||
| 3657 | Transition Splice to 400 pair Building Cable | 1 | EA | 1 | EA | ||||||||||
| 3658 | 400 pair Protected Terminal Block equipped with Protector Gas Modules | 1 | EA | 1 | EA | ||||||||||
| 600 Pair Cable, 24 Gauge | |||||||||||||||
| 3660 | Vault Splice for 600 pair Building Cable | 1 | EA | 1 | EA | ||||||||||
| 3661 | Transition Splice to 600 pair Building Cable | 1 | EA | 1 | EA | ||||||||||
| 3662 | 600 pair Protected Terminal Block equipped with Protector Gas Modules | 1 | EA | 1 | EA | ||||||||||
| 900 Pair Cable, 24 Gauge | |||||||||||||||
| 3664 | Vault Splice for 900 pair Building Cable | 1 | EA | 1 | EA | ||||||||||
| 3665 | Transition Splice to 900 pair Building Cable | 1 | EA | 1 | EA | ||||||||||
| 3666 | 900 pair Protected Terminal Block equipped with Protector Gas Modules | 1 | EA | 1 | EA | ||||||||||
| OUTSIDE PLANT PEDESTAL PROTECTED TERMINAL BLOCKS equipped with protector modules | |||||||||||||||
| Protected Blocks: | |||||||||||||||
| 3672 | 6 pair Terminal block | 2 | EA | 2 | EA | ||||||||||
| 3673 | 12 pair Terminal block | 2 | EA | 2 | EA | ||||||||||
| 3674 | 25 pair Terminal block | 4 | EA | 4 | EA | ||||||||||
| 3675 | 50 pair Terminal block | 4 | EA | 4 | EA | ||||||||||
| 3676 | 100 pair Terminal block | 1 | EA | 1 | EA | ||||||||||
| OUTSIDE PLANT PEDESTAL WITHOUT PROTECTED TERMINAL BLOCKS not equipped with protector modules | |||||||||||||||
| Fiber Optic Cable, PE 90, Armored (For direct buried installation) | |||||||||||||||
| 3705 | 6 Fiber Single Mode Cable | 400 | MR | ||||||||||||
| 3707 | 12 Fiber Single Mode Cable | 10,000 | MR | ||||||||||||
| 3708 | 12 Fiber Multi-Mode Cable | 5,000 | MR | ||||||||||||
| 3710 | 24 Fiber Single Mode Cable | 5,000 | MR | ||||||||||||
| 3711 | 24 Fiber Multi-Mode Cable | 1,000 | MR | ||||||||||||
| 3715 | 36 Fiber Single Mode Cable | 5,000 | MR | ||||||||||||
| 3717 | 48 Fiber Single Mode Cable | 5,000 | MR | ||||||||||||
| 3723 | 72 Fiber Multi-mode Cable | 5,000 | MR | ||||||||||||
| 3725 | 96 Fiber Composite (48 SM/48 MM) | 1,000 | MR | ||||||||||||
| MANHOLES/CONDUIT for UNDERGROUND PLANT HARDWARE | |||||||||||||||
| 3732 | 4 inch 1-Way Ducts, Schedule 40 | 10,000 | FT | 10000 | FT | ||||||||||
| 3733 | 4 inch 2-Way Ducts, Schedule 40 | 10,000 | FT | 10000 | FT | ||||||||||
| 3734 | 4 inch 2-Way Ducts, Schedule 80 | 500 | FT | 500 | FT | ||||||||||
| 3735 | 4 inch 4-Way Ducts, Schedule 40 | 500 | FT | 500 | FT | ||||||||||
| 3737 | 4 inch 4-Way Ducts; includes 1 ea 4-way fiber Duct | 500 | FT | 500 | FT | ||||||||||
| 3738 | 4 inch 4-Way Fiber Ducts | 500 | FT | 500 | FT | ||||||||||
| 3739 | 4 inch Split Ducts (Conduit Repair) | 500 | FT | 500 | FT | ||||||||||
| 3740 | 1 inch Fiber Optic Innerducts | 100,000 | FT | 100000 | FT | ||||||||||
| 3741 | 1 inch Fiber Optic Innerducts, Plenum | 40,000 | FT | 40000 | FT | ||||||||||
| 4365 | Traffic grate Handhole Lid 4' WD x 6' LT | 3 | EA | 3 | JB | ||||||||||
| 4367 | Marker Ball (Note: Installation price includes digging, placement, site restoration, and all material) | 3 | EA | 3 | JB | ||||||||||
| BUILDING INSIDE STRUCTURE CABLE AND DISTRIBUTION | |||||||||||||||
| LAN Fault Isolation and Data Rate Testing : | |||||||||||||||
| CHANNEL ACTIVATION : (These are always to be included) | |||||||||||||||
| 3754 | 2-Wire Circuit | 100 | JB | ||||||||||||
| 3755 | 4-Wire Circuit | 500 | JB | ||||||||||||
| 3756 | 4-Wire Data Service Unit | 25 | JB | ||||||||||||
| 3757 | 4-Wire DX Signalling Unit | 25 | JB | ||||||||||||
| 3758 | 2-Wire Channel Unit Card | 10 | JB | ||||||||||||
| 3759 | 4-Wire Channel Unit Card | 10 | JB | ||||||||||||
| 3760 | DS1 | 3 | JB | ||||||||||||
| 3761 | DS3 | 3 | JB | ||||||||||||
| 3762 | T-1 | 25 | JB | ||||||||||||
| 3763 | Trunk Port Activation | 25 | JB | ||||||||||||
| 3764 | OC-1 | 3 | JB | ||||||||||||
| 3765 | OC-3 | 3 | JB | ||||||||||||
| DEMARCATION POINT CROSS-CONNECTIONS : | |||||||||||||||
| (These are always to be included) | |||||||||||||||
| 3767 | LAN | 1000 | JB | ||||||||||||
| 3768 | 2-Wire Circuit | 200 | JB | ||||||||||||
| 3769 | 4-Wire Circuit | 300 | JB | ||||||||||||
| 3770 | DS1 | 3 | JB | ||||||||||||
| 3771 | DS3 | 3 | JB | ||||||||||||
| 3772 | T-1 | 25 | JB | ||||||||||||
| 3773 | OC-1 | 3 | JB | ||||||||||||
| 3774 | OC-3 | 3 | JB | ||||||||||||
| POINT-TO-POINT CROSS-CONNECTIONS : | |||||||||||||||
| (These are always to be included) | |||||||||||||||
| 3778 | LAN | 1000 | JB | ||||||||||||
| 3779 | 2-Wire Circuit | 200 | JB | ||||||||||||
| 3780 | 4-Wire Circuit | 300 | JB | ||||||||||||
| 3781 | DS1 | 3 | JB | ||||||||||||
| 3782 | DS3 | 3 | JB | ||||||||||||
| 3783 | T-1 | 25 | JB | ||||||||||||
| 3784 | OC-1 | 3 | JB | ||||||||||||
| 3785 | OC-3 | 3 | JB | ||||||||||||
| OUTSIDE PLANT CABLE AND DISTRIBUTION | |||||||||||||||
| METALLIC CABLE TERMINATION to EXISTING SPLICE | |||||||||||||||
| 3790 | 6 Pair | 3 | JB | ||||||||||||
| 3791 | 12 Pair | 3 | JB | ||||||||||||
| 3792 | 25 Pair | 5 | JB | ||||||||||||
| 3793 | 50 Pair | 4 | JB | ||||||||||||
| 3794 | 100 Pair | 4 | JB | ||||||||||||
| 3795 | 200 Pair | 2 | JB | ||||||||||||
| 3796 | 300 pair | 1 | JB | ||||||||||||
| 3797 | 600 pair | 1 | JB | ||||||||||||
| CABLE INSTALLATION | |||||||||||||||
| Metallic Cable in Existing Trench (Direct Buried): | |||||||||||||||
| 3803 | Placement of Metallic Cable (up to 50 pair) into Existing Trench | 5000 | FT | ||||||||||||
| 3804 | Placement of Metallic Cable (75 pair) into Existing Trench | 5000 | FT | ||||||||||||
| 3805 | Placement of Metallic Cable (100 pair) into Existing Trench | 5000 | FT | ||||||||||||
| 3806 | Placement of Metallic Cable (150 pair) into Existing Trench | 1500 | FT | ||||||||||||
| 3807 | Placement of Metallic Cable (200 pair) into Existing Trench | 1000 | FT | ||||||||||||
| 3808 | Placement of Metallic Cable (300 pair) into Existing Trench | 1000 | FT | ||||||||||||
| 3809 | Placement of Metallic Cable (400 pair) into Existing Trench | 1000 | FT | ||||||||||||
| 3810 | Placement of Metallic Cable (600 pair) into Existing Trench | 1000 | FT | ||||||||||||
| 3811 | Placement of Metallic Cable (900 pair) into Existing Trench | 1000 | FT | ||||||||||||
| 3812 | Placement of Metallic Cable (1200 pair) into Existing Trench | 1000 | FT | ||||||||||||
| 3813 | Placement of Metallic Cable (1500 pair) into Existing Trench | 1000 | FT | ||||||||||||
| 3814 | Placement of Metallic Cable (1800 pair) into Existing Trench | 1000 | FT | ||||||||||||
| 3815 | Placement of Metallic Cable (2100 pair) into Existing Trench | 500 | FT | ||||||||||||
| 3816 | Placement of Metallic Cable (2400 pair) into Existing Trench | 500 | FT | ||||||||||||
| Metallic Cable in Existing Conduit: | |||||||||||||||
| 3824 | Pulling Metallic Cable (up to 50 pair) through Existing Conduit | 5000 | FT | ||||||||||||
| 3825 | Pulling Metallic Cable (75 pair) through Existing Conduit | 5000 | FT | ||||||||||||
| 3826 | Pulling Metallic Cable (100 pair) through Existing Conduit | 5000 | FT | ||||||||||||
| 3827 | Pulling Metallic Cable (150 pair) through Existing Conduit | 1500 | FT | ||||||||||||
| 3828 | Pulling Metallic Cable (200 pair) through Existing Conduit | 1000 | FT | ||||||||||||
| 3829 | Pulling Metallic Cable (300 pair) through Existing Conduit | 1000 | FT | ||||||||||||
| 3830 | Pulling Metallic Cable (400 pair) through Existing Conduit | 1000 | FT | ||||||||||||
| 3831 | Pulling Metallic Cable (600 pair) through Existing Conduit | 1000 | FT | ||||||||||||
| 3832 | Pulling Metallic Cable (900 pair) through Existing Conduit | 1000 | FT | ||||||||||||
| 3833 | Pulling Metallic Cable (1200 pair) through Existing Conduit | 1000 | FT | ||||||||||||
| 3834 | Pulling Metallic Cable (1500 pair) through Existing Conduit | 1000 | FT | ||||||||||||
| 3835 | Pulling Metallic Cable (1800 pair) through Existing Conduit | 1000 | FT | ||||||||||||
| 3836 | Pulling Metallic Cable (2100 pair) through Existing Conduit | 1000 | FT | ||||||||||||
| 3837 | Pulling Metallic Cable (2400 pair) through Existing Conduit | 1000 | FT | ||||||||||||
| FIBER OPTIC CABLE INSTALLATION | |||||||||||||||
| Fiber Optic Cable in Existing Trench (Direct Buried): | |||||||||||||||
| 3846 | Placement of Fiber Optic Cable (6-72 Fiber) into Existing Trench | 1500 | FT | ||||||||||||
| 3847 | Placement of Fiber Optic Cable (96-144 Fiber) into Existing Trench | 1500 | FT | ||||||||||||
| Fiber Optic Cable in Existing Duct/Innerduct: | |||||||||||||||
| 3851 | Pulling Fiber Optic Cable (6-72 Fiber) through Existing Duct/Innerduct | 80000 | FT | ||||||||||||
| SURFACE PREPARATION / RESTORATION for OUTSIDE PLANT CABLE | |||||||||||||||
| 3856 | Rod, Clean, & Pull Rope through existing duct | 100000 | FT | ||||||||||||
| 3857 | Trenching through and restoration of Soft Surfaces, 6" wide, 30" deep [ single conduit] | 20000 | FT | ||||||||||||
| 3859 | Trenching through and restoration of Soft Surfaces, 18" wide, 30" deep [ 1x2 conduit layout] | 20000 | FT | ||||||||||||
| 3861 | Trenching through and restoration of Soft Surfaces, 18" wide, 40" deep [ 2x2 conduit layout] | 3000 | FT | ||||||||||||
| 3863 | Trenching through and restoration of Soft Surfaces, 30" wide, 40" deep [ 2x4 conduit layout] | 2000 | FT | ||||||||||||
| 3865 | Trenching through and restoration of Hard Surfaces, 6" wide, 30" deep [single conduit] | 500 | FT | ||||||||||||
| 3867 | Trenching through and restoration of Hard Surfaces, 18" wide, 30" deep [ 1x2 conduit layout] | 1000 | FT | ||||||||||||
| 3869 | Trenching through and restoration of Hard Surfaces, 18" wide, 40" deep [ 2x2 conduit layout] | 1000 | FT | ||||||||||||
| 3871 | Trenching through and restoration of Hard Surfaces, 30" wide, 40" deep [ 2x4 conduit layout] | 1000 | FT | ||||||||||||
| 4958 | Cutting through Asphalt, 24" wide | 30 | FT | ||||||||||||
| 3875 | Cutting through Concrete, 24" wide | 30 | FT | ||||||||||||
| 3879 | Reseeding | 500 | SQ FT | ||||||||||||
| 3880 | Resodding | 500 | SQ YD | ||||||||||||
| MANHOLES/CONDUIT for UNDERGROUND PLANT HARDWARE | |||||||||||||||
| 5201 | Furnish and Install a 5 Ft. L x 7 Ft. W x 7 Ft. H Manhole, (Note: Installation price includes digging, placement, site restoration, and all material) | 25 | JB | ||||||||||||
| 3891 | Placement of Conduit (Drill Hole) into Existing Manhole (Note: Installation price includes all required material for one 4 inch conduit, 5 foot stub length) | 40 | JB | ||||||||||||
| 3892 | Placement of Conduit (Remove Knockout Plug) into Existing Manhole (Note: Installation price includes all required material for one 4 inch conduit, 5 foot stub length) | 20 | JB | ||||||||||||
| 3893 | Placement of Conduit into Building Entry Point (Note: Installation price includes all required material) | 20 | JB | ||||||||||||
| 3894 | Furnish and Install a 4 Ft. W x 4 Ft. L x 4 Ft. H Handhole (Note: Installation price includes all required material) | 10 | JB | ||||||||||||
| 3895 | Furnish and Install a 4 Ft. W x 6 Ft. L x 4 Ft. H Handhole (Note: Installation price includes all required material) | 15 | JB | ||||||||||||
| 3896 | Furnish and Install a 4 Ft. W x 6 Ft. L x 6 Ft. H Handhole (Note: Installation price includes all required material) | 10 | JB | ||||||||||||
| CONDUIT INSTALLATION and BORING | |||||||||||||||
| 3899 | Bore through or under Hard Surface and Install 4 inch 2-Way Ducts into the Bore, Purchase Schedule 80 conduit under separate SLIN | 6000 | FT | ||||||||||||
| 3901 | Bore through or under Hard Surface and Install 4 inch 4-Way Ducts into the Bore, Provide and Install casing, Purchase Schedule 40 conduit under separate SLIN | 1000 | FT | ||||||||||||
| 4418 | Bore through or under Soft Surface | 1500 | FT | ||||||||||||
| 4419 | Core Drill 2" Hole Through 6" - 8" Wall (Concrete) | 5 | JB | ||||||||||||
| 4420 | Core Drill 2" Hole Through 6" - 8" Wall (Dry Wall) | 5 | JB | ||||||||||||
| 4421 | Core Drill 5" Hole Through 6" - 8" Wall (Concrete) | 6 | JB | ||||||||||||
| 4422 | Core Drill 5" Hole Through 6" - 8" Wall (Dry Wall) | 6 | JB | ||||||||||||
| Fiber Optic Innerducts | |||||||||||||||
| 3908 | Pulling Four - 1" Fiber Optic Innerducts through Existing Conduit | 80000 | FT | ||||||||||||
| 4444 | Placing 4" 4'way fiber ducts in existing trench | 10000 | FT | ||||||||||||
| 3909 | Placing Fiber Optic Innerduct in Existing Trench | 10000 | FT | ||||||||||||
| SPLICE PIT EXCAVATION: When associated with a Cable Cut and Repair the price includes preparation of damaged cable end for splicing; otherwise the price is for the excavation only. | |||||||||||||||
| 3916 | Single Splice Pit: Excavation, Backfill, and Restoration of Soft Surfaces | 5 | JB | ||||||||||||
| 3917 | Single Splice Pit: Excavation, Backfill, and Restoration of Hard Surfaces | 5 | JB | ||||||||||||
| 3919 | Dual Splice Pit and Connecting 25 ft Trench to Splice / Repair Bad Section: Excavation, Backfill, and Restoration of Soft Surfaces | 2 | JB | ||||||||||||
| 3920 | Dual Splice Pit and Connecting 25 ft Trench to Splice / Repair Bad Section: Excavation, Backfill, and Restoration of Hard Surfaces | 2 | JB | ||||||||||||
| 3921 | Dual Splice Pit and Connecting 25 ft Trench to Splice / Repair Bad Section: Excavation, Backfill, and Restoration of Rock Bases | 2 | JB | ||||||||||||
| Conduit Damage and Repair Setup | |||||||||||||||
| 3923 | 4 inch Conduit Removal and Repair per 10 foot span - no cable inside conduit (all miscellaneous material included) | 2 | JB | ||||||||||||
| 3924 | 4 inch Conduit Removal and Repair per 10 foot span - cable inside conduit (all miscellaneous material included) | 2 | JB | ||||||||||||
| 3925 | 4 inch Conduit Removal and Repair per 20 foot span - no cable inside conduit (all miscellaneous material included) | 2 | JB | ||||||||||||
| 3926 | 4 inch Conduit Removal and Repair per 20 foot span - cable inside conduit (all miscellaneous material included) | 2 | JB | ||||||||||||
| VENDOR SPECIFIC EQUIPMENT LIST | |||||||||||||||
| AVAYA EQUIPMENT | |||||||||||||||
| DEFINITY CONSOLES & VOICE TERMINALS: | |||||||||||||||
| 3972 | 6408D+M Digital Phone, With Display, 2 Lines Speaker Phone and 8 Buttons | 75 | EA | 75 | EA | ||||||||||
| 3973 | 6416D+M Digital Phone 2 Lines,With Display, Speaker Phone and 16 Buttons | 50 | EA | 50 | EA | ||||||||||
| 3974 | 6424D+M Digital Phone,With Display, 2 Lines Speaker Phone and 24 Buttons | 40 | EA | 40 | EA | ||||||||||
| 3984 | 8410D DVT w/ Display | 75 | EA | 75 | EA | ||||||||||
| 3985 | 8434D 34-Button DVT And Power | 25 | EA | 25 | EA | ||||||||||
| 3987 | Auxiliary Power Supply for 8434 Set | 20 | EA | 20 | EA | ||||||||||
| DEFINITY ISDN TERMINALS: | |||||||||||||||
| 4516 | I2022 ISDN Telephone with Display | 10 | JB | 10 | JB | ||||||||||
| 4517 | U interface module for the I2022 | 10 | JB | 10 | JB | ||||||||||
| 4518 | 6210 Tone Commander ISDN Sets With Display | 10 | JB | 10 | JB | ||||||||||
| 4519 | 6220 Tone Commander ISDN Sets With Display | 10 | JB | 10 | JB | ||||||||||
| 4520 | Power supply for 6210 tone Commander | 10 | JB | 10 | JB | ||||||||||
| SWITCHING SYSTEMS : (other than circuit card additions, module system expansions will not be performed under this contract unless negotiated by modification) | |||||||||||||||
| DEFINITY G1 & G3 PROVISIONING CIRCUIT PACKS: | |||||||||||||||
| 4018 | TN417 Auxiliary Trunk, G3i-G3r, 4 Port for On-Premise Trunk: Music, Paging Spkr, Recorded/Dictation | 1 | EA | 1 | EA | ||||||||||
| 4019 | TN429 DIOD Trunk, G3i-G3r, 8 Ports | 2 | EA | 2 | EA | ||||||||||
| 4022 | TN437 TIE Trunk, G3i-G3r, 4 Port for 4-wire E&M Immediate/WS/Delay Dial | 1 | EA | 1 | EA | ||||||||||
| 4025 | TN447 CO Trunk, G3i-G3r, 8 Ports GS | 1 | EA | 1 | EA | ||||||||||
| 4030 | TN464 DS1 TIE Trunk, DS1 ISDN PRI (G3r), or E1 | 1 | EA | 1 | EA | ||||||||||
| 4035 | TN553 Packet Data Line, G3r | 1 | EA | 1 | EA | ||||||||||
| 4036 | TN556 ISDN BRI Line, 12 Ports for BRI Terminals | 1 | EA | 1 | EA | ||||||||||
| 4037 | TN570C Expansion Interface Card | 1 | EA | 1 | EA | ||||||||||
| 4038 | TN572 Switch-Node Block Interface for G3r | 1 | EA | 1 | EA | ||||||||||
| 4039 | TN573B Switch Node Interface | 1 | EA | 1 | EA | ||||||||||
| 4040 | TN574 DS1 Converter for G3r | 1 | EA | 1 | EA | ||||||||||
| 4041 | TN577 Packet Gateway, G3r, 4 Ports for X.25 Protocol Interfaces | 1 | EA | 1 | EA | ||||||||||
| 4042 | TN726B Data Line Interface, 8-Ports | 1 | EA | 1 | EA | ||||||||||
| 4043 | TN746B Analog Line, 16-Port | 1 | EA | 1 | EA | ||||||||||
| 4044 | TN747B CO Trunk, G3i-G3r, 8 Ports | 1 | EA | 1 | EA | ||||||||||
| 4045 | TN750C Announcement Card | 1 | EA | 1 | EA | ||||||||||
| 4047 | TN775 B/C EPN Maintenance Board for G3si/r | 1 | EA | 1 | EA | ||||||||||
| 4048 | TN771 Difinity Maintenance Test Circuit Pack | 1 | EA | 1 | EA | ||||||||||
| 4049 | TN793B Analog Line, 24 Ports | 1 | EA | 1 | EA | ||||||||||
| 4050 | TN799B C-LAN (Control Local Area Network) Interface | 1 | EA | 1 | EA | ||||||||||
| 4051 | TN1648B System Access And Maintenance For G3r | 1 | EA | 1 | EA | ||||||||||
| 4052 | TN1650B I Meg Memory For G3r | 1 | EA | 1 | EA | ||||||||||
| 4053 | TN1654 DS1 Converter, T1 (24 channel) | 1 | EA | 1 | EA | ||||||||||
| 4054 | TN1655 Packet Interface for G3r | 1 | EA | 1 | EA | ||||||||||
| 4055 | TN767 DS1/ISDN PRI | 4 | EA | 4 | EA | ||||||||||
| 4056 | TN469 Analog Line, 8 Ports (neon), ONS or OPS w/ protection | 1 | EA | 1 | EA | ||||||||||
| 4064 | TN2147 CO Trunk, G3i-G3r, 8 Ports | 1 | EA | 1 | EA | ||||||||||
| 4066 | TN2182C Tone Clock, Tone Detector & Call Classifier | 1 | EA | 1 | EA | ||||||||||
| 4067 | TN2198 2-W ISDN BRI (Basic Rate Interface) Line | 4 | EA | 4 | EA | ||||||||||
| 4068 | TN2211 Optical Drive for G3r | 1 | EA | 1 | EA | ||||||||||
| 4069 | TN2224B 2W Digital Line, 24-Port | 15 | EA | 15 | EA | ||||||||||
| 4070 | TN2302 IP Media Processor Circuit Pack | 1 | EA | 1 | EA | ||||||||||
| 4071 | UN330B Duplication Interface for G3r | 1 | EA | 1 | EA | ||||||||||
| 4072 | UN331B Duplication Processor for G3r | 1 | EA | 1 | EA | ||||||||||
| 4073 | UN332B/C Data Storage/Network Control for G3r | 1 | EA | 1 | EA | ||||||||||
| POLY TELECONFERENCE EQUIPMENT | |||||||||||||||
| 4392 | Polycom ProVoiceStation 100 | 0 | EA | 0 | JB | ||||||||||
| 4393 | Polycom SoundStation | 2 | EA | 2 | JB | ||||||||||
| 4394 | Polycom SoundStation Premier w/IR Remote Keypad and Two extended Hypercardioid Microphones | 1 | EA | 1 | JB | ||||||||||
| TELLABS CONFERENCE SYSTEM CIRCUIT | |||||||||||||||
| 4236 | Tellabs 9193 2-Wire ARD Conference Originate Line Circuit or equivalent | 1 | EA | 1 | EA | ||||||||||
| 4237 | Tellabs 9194 2-Wire ARD Conference Amplifier or equivalent | 1 | EA | 1 | EA | ||||||||||
| 4238 | Tellabs 9193 Tone Supply or equivalent | 1 | EA | 1 | EA | ||||||||||
| 4239 | Tellabs 9132 Ringing Timer or equivalent | 1 | EA | 1 | EA | ||||||||||
| 4240 | Tellabs 9003A Ring Interrupter Control Module or equivalent | 1 | EA | 1 | EA | ||||||||||
| 4241 | Tellabs 9021 Alarm or equivalent | 1 | EA | 1 | EA | ||||||||||
| 4242 | Tellabs 9191 2-Wire ARD Conference Terminate Line Circuit or equivalent | 1 | EA | 1 | EA | ||||||||||
| 4243 | Tellabs 9196 2-Wire ARD Loop Start Access Trunk or equivalent | 1 | EA | 1 | EA | ||||||||||
| 4244 | Tellabs 9002 Relay Module 48 Vdc or equivalent | 1 | EA | 1 | EA | ||||||||||
| 4245 | Tellabs 7201 2-Wire Switched Gain Repeater or equivalent | 1 | EA | 1 | EA | ||||||||||
| 4246 | Tellabs 3228 Data Set xmt/rcv or equivalent | 1 | EA | 1 | EA | ||||||||||
| 4247 | Tellabs 81-8108 Ring Generator or equivalent | 1 | EA | 1 | EA | ||||||||||
| 4248 | Tellabs 9293 2-Wire ARD Conference Originate Line Circuit or equivalent | 1 | EA | 1 | EA | ||||||||||
| 4249 | Tellabs 9294 2-Wire ARD Conference Amplifier or equivalent | 1 | EA | 1 | EA | ||||||||||
| 4250 | Tellabs 9121 Tone Supply or equivalent | 1 | EA | 1 | EA | ||||||||||
| 4251 | Tellabs 9291 2-Wire ARD Conference Terminate Line Circuit or equivalent | 1 | EA | 1 | EA | ||||||||||
| 4252 | Tellabs Relay Module or equivalent | 1 | EA | 1 | EA | ||||||||||
| 4253 | Tellabs 4001C Line Amplifier or Equivalent | 1 | EA | 1 | EA | ||||||||||
| 4254 | Tellabs 4410 Pad/Xfmr or equivalent | 1 | EA | 1 | EA | ||||||||||
| 4255 | Tellabs 4422 Dual Repeat Coil or equivalent | 1 | EA | 1 | EA | ||||||||||
| 4256 | Tellabs 6003 Autoringdown 2W Coil or equivalent | 1 | EA | 1 | EA | ||||||||||
| 4257 | Tellabs 6131 2/4 Wire-4 Wire Terminal Interface Module or equivalent | 1 | EA | 1 | EA | ||||||||||
| 4258 | Tellabs 8050 Regulated DC Power Supply and Ringing Generator w/ Lamp Output or equivalent | 1 | EA | 1 | EA | ||||||||||
| 4259 | Tellabs 8103 Ringing Generator or equivalent | 1 | EA | 1 | EA | ||||||||||
| 4260 | Tellabs 9117 Voice Operated Switch Module or equivalent | 1 | EA | 1 | EA | ||||||||||
| Part I - A & B Grand Total: | $0.00 | $0.00 | $0.00 | $0.00 | $0.00 | $0.00 | $0.00 | $0.00 | $0.00 | $0.00 |
&"Arial,Regular"&12PRICING TABLE
&"Times New Roman,Regular"Attachment 1 &"Times New Roman,Regular"&P of &N &"Times New Roman,Regular"&A
C & D (CLINs X006-7) & X008-X-9
| Altus AFB OK | |||||||||||||||
| FA8773-09-R-0002 | |||||||||||||||
| 14-Jul-09 | |||||||||||||||
| BASE PERIOD | OPTION PERIOD 1 | OPTION PERIOD 2 | OPTION PERIOD 3 | OPTION PERIOD 4 | |||||||||||
| EST REMOVAL QTY | EST RELOCATION QTY | REMOVAL PRICE | RELOCATE PRICE | REMOVAL PRICE | RELOCATE PRICE | REMOVAL PRICE | RELOCATE PRICE | REMOVAL PRICE | RELOCATE PRICE | REMOVAL PRICE | RELOCATE PRICE | ||||
| Product ID | DESCRIPTION | C | D | C | D | C | D | C | D | C | D | C | D | ||
| GENERIC EQUIPMENT LIST | |||||||||||||||
| CUSTOMER PREMISE EQUIPMENT | |||||||||||||||
| TELEPHONE STATIONS | |||||||||||||||
| 3005 | Basic Telephone | 100 | JB | 200 | JB | ||||||||||
| 3014 | Outdoor Telephone | 3 | JB | 3 | JB | ||||||||||
| 3015 | Hazardous Area / Explosion Proof Telephone | 1 | JB | 1 | JB | ||||||||||
| 3018 | Wall Phone | 10 | JB | 10 | JB | ||||||||||
| UNIVERSAL KEY SYSTEM SETS | |||||||||||||||
| 3024 | Key System Size I, Initially Equipped for 8 Main Line & 16 Station Lines | 1 | JB | 1 | JB | ||||||||||
| 3028 | Key System Size II, Initially Equipped for 12 Main Lines & 24 Station Lines | 5 | JB | 5 | JB | ||||||||||
| 3032 | Key System Size III, Initially Equipped for 24 Main Lines & 48 Station Lines | 5 | JB | 5 | JB | ||||||||||
| VENDOR SPECIFIC EQUIPMENT LIST | |||||||||||||||
| AVAYA EQUIPMENT | |||||||||||||||
| SYSTEM 25 TELEPHONES & ACCESSORIES: | |||||||||||||||
| 3944 | BIS-10 W/ Built-In Speakerphone | 50 | JB | 50 | JB | ||||||||||
| 3946 | BIS-22D W/ Built-In Speakerphone & Display | 10 | JB | 10 | JB | ||||||||||
| 3948 | System 25 Attendant Console | 3 | JB | 4 | JB | ||||||||||
| DEFINITY CONSOLES & VOICE TERMINALS: | |||||||||||||||
| 3972 | 6408D+M Digital Phone, With Display, 2 Lines Speaker Phone and 8 Buttons | 50 | JB | 100 | JB | ||||||||||
| 3973 | 6416D+M Digital Phone 2 Lines,With Display, Speaker Phone and 16 Buttons | 50 | JB | 100 | JB | ||||||||||
| 3974 | 6424D+M Digital Phone,With Display, 2 Lines Speaker Phone and 24 Buttons | 25 | JB | 60 | JB | ||||||||||
| 3982 | 8403 DVT | 10 | JB | 10 | JB | ||||||||||
| 3983 | 8410B DVT | 10 | JB | 10 | JB | ||||||||||
| 3984 | 8410D DVT w/ Display | 50 | JB | 150 | JB | ||||||||||
| 3985 | 8434D 34-Button DVT And Power | 10 | JB | 100 | JB | ||||||||||
| SWITCHING SYSTEMS : (other than circuit card additions, module system expansions will not be performed under this contract unless negotiated by modification) | |||||||||||||||
| C & D Grand Total: | $0.00 | $0.00 | $0.00 | $0.00 | $0.00 | $0.00 | $0.00 | $0.00 | $0.00 | $0.00 | |||||
| CLIN X008 - GPS Data Collection Svcs | EST QTY | U/I | UNIT PRICE | EXTENDED PRICE | UNIT PRICE | EXTENDED PRICE | UNIT PRICE | EXTENDED PRICE | UNIT PRICE | EXTENDED PRICE | UNIT PRICE | EXTENDED PRICE | |||
| 2260 | Direct Buried Cable (LF = price per linear foot collected) | 75000 | LF | $0.00 | $0.00 | $0.00 | $0.00 | $0.00 | |||||||
| 2261 | Underground Cable (LF = price per linear foot collected) | 75000 | LF | $0.00 | $0.00 | $0.00 | $0.00 | $0.00 | |||||||
| 2262 | Manhole, Handhole, Pedestal, or Splice (EA = price per data point collected) | 10 | EA | $0.00 | $0.00 | $0.00 | $0.00 | $0.00 | |||||||
| TOTAL CLIN X008: | $0.00 | $0.00 | $0.00 | $0.00 | $0.00 | ||||||||||
| CLIN X009 | EST QTY | U/I | UNIT PRICE | EXTENDED PRICE | UNIT PRICE | EXTENDED PRICE | UNIT PRICE | EXTENDED PRICE | UNIT PRICE | EXTENDED PRICE | UNIT PRICE | EXTENDED PRICE | |||
| 2244 | Telecommunications Mechanic I | 500 |
pam.mcgowen: pam.mcgowen:
| THESE HOURS SHOULD BE RELATIVE TO THE ACTUAL T&M HOURS USED DURING THE PREVIOUS 3-5 YEARS, AVERAGED. | HR | $0.00 | $0.00 | $0.00 | $0.00 | $0.00 | ||||||||
| 2245 | Telecommunications Mechanic II | 500 | HR | $0.00 | $0.00 | $0.00 | $0.00 | $0.00 | ||||||
| 2246 | Telephone Lineman | 500 | HR | $0.00 | $0.00 | $0.00 | $0.00 | $0.00 | ||||||
| 2247 | Cable Splicer | 500 | HR | $0.00 | $0.00 | $0.00 | $0.00 | $0.00 | ||||||
| 2249 | Laborer | 500 | HR | $0.00 | $0.00 | $0.00 | $0.00 | $0.00 | ||||||
| TOTAL CLIN X009: | $0.00 | $0.00 | $0.00 | $0.00 | $0.00 |
&"Times New Roman,Regular"&12PRICING TABLE
&"Times New Roman,Regular"Attachment 1 &"Times New Roman,Regular"&P of &N &"Times New Roman,Regular"&A
File details come from the government source that posted it. Updated .