This document includes a questions and answers set and federal contract opportunity solicitation. The solicitation seeks proposals for a Baggage Conveyor System at Yokota Air Base in Japan. The system will be installed in Building 80 and include conveyors, a scale conveyor, and integration with a new X-ray machine. Proposals are due by July 7, 2021. The contract will be awarded to the lowest priced technically acceptable offer using LPTA evaluation. The contract must be completed within 300 days of award. The solicitation is set aside for small businesses with less than 500 employees. The NAICS code is 333922. The Department of the Air Force Materiel Command Lifecycle Management Center at Wright Patterson Air Force Base is the contracting agency.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
FA8604‐21‐R‐B014
Yokota Air Base, Japan Questions/Answers Set 2 24 June 2021
Questions/Responses:
1. Please advise if the X‐ray machine is installed before the delivery of baggage handling conveyors.
Yes, current plans are that a new X‐ray machine will be on‐site before the delivery of the conveyors.
2. Please advise if check‐in counters, which is out scope of this RPF, are installed before the delivery of baggage handling conveyors.
Yes, current plans are that the check‐in counters will be installed before the delivery.
3. Please advice if floors, walls and ceiling of building #80 are finished before the delivery of baggage handling conveyors.
The building 80 renovations/constructions should be complete before the delivery.
4. Does "the existing electrical supplies located in each building." mean "Electrical 141" on E‐105 drawing? Or, would distribution boards for conveyors be provided separately at other location?
On E‐105 drawing, Electrical 141 is the electrical room for the whole building, so that will be where the electrical panels and boards will be located. The newly provided panelboards (per the Cover PD, 3.2.2.) will be installed and connected to the existing power source in this room.
5. Maximum baggage size "30" wide x 60" long x 36" high" won't fit in a scale conveyor. Please advise how it should be handled.
The max‐sized baggage will be handled manually by personnel, i.e. the scale conveyor will not be used.
6. Is it possible the scale conveyor ramped instead of dispatch conveyor? Please see attachment 11(dimensions should be varied) for example.
The ramped scale conveyor your provided attachment 11 would be possible.
7. Please advise conveying height and opening dimension of X‐ray machine. (Informing the model No. of X‐ray would work.)
A new x‐ray machine is scheduled to be procured. The brands/model not known at this time. However, the x‐ray machine will be on‐site before the delivery of the conveyors.