MMHS Osan Questions and Answers
FA8604-19-R-8108
Set 3 04/01/2019
Q1. In an earlier response to a question, What is the duty cycle of the Pallet Lifts?”
The answer provided was “15 – 20 cycles per day”
Is that is an 8 hour shift, or, in a full 24-hour day?
16 Hours/Day
Q2. Reference Attachment # 2 – Page 11 of 33 – Section 3.2.8.5.1.5. CYLINDERS
“The surface finish on piston rods and cylinder bore shall be from 0.12 to 0.38 micrometers.”
Would a 0.40 micrometer finish be acceptable? No
Q3. Reference Attachment #2 – Page 12 of 33 – Section 3.2.8.5.1.9. RESERVOIRS
“Access shall be provided thru bolt-on gasketed top and end covers.”
Would a top cover access only be acceptable? Yes