APPENDIX A.docx
DOCX document 41 KB Posted
- Attached to
- Storage Aid System (SAS) - Fairchild AFB, WA
- Solicitation number
- FA8604-12-R-7955
About this file
Appendix A
View the file
Other files
| File | Type | Posted |
|---|---|---|
| ADD_I.docx | DOCX document | |
| ADD_I.docx | DOCX document | |
| FA8604-12-R-7955_0001.pdf | ||
| DI DRPR 81003.pdf | ||
| DI MGMT 80909 T.pdf | ||
| APPENDIX D.docx | DOCX document | |
| BFR1B0-01.dwg | DWG drawing | |
| a002.doc | DOC document | |
| DI TMSS 80527.pdf | ||
| APPENDIX B.docx | DOCX document | |
| Notification_of_Compliance_with_Contract_Insurance_Requirements_(Sols).docx | DOCX document | |
| DI MGMT 80227 T.pdf | ||
| Contractor Information | — | |
| BFR1B0-03.dwg | DWG drawing | |
| BFR1B0-02.dwg | DWG drawing | |
| a003.doc | DOC document | |
| APPENDIX C.docx | DOCX document | |
| a004.doc | DOC document | |
| A001.doc | DOC document | |
| FA860412R7955_RFP.pdf | ||
| a006.doc | DOC document | |
| Cover PD.docx | DOCX document | |
| a007.doc | DOC document |
Show all 23
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
TECHNICAL PROPOSAL QUESTIONNAIRE
FOR
Offeror: _ Solicitation No. F33600- -R- _
Offeror:
| Solicitation Number: |
| FA8604- |
-R-
GAPPENDIX A
PALLET RACK
AT
FAIRCHILD AIR FORCE BASE, WASHINGTON
BUILDING 2163
CSN: BFR1B0
DATE: 31 August 2011
PREPARED BY:
Shane M. Legge
PROJECT ENGINEER
403 SCMS/GUEC
DONNA L. HARTMAN
REVIEWER
403 SCMS/GUEC
Table of Contents
| 1. General scope | 1 |
| 1.1. Definitions | 1 |
| 2. APPLICABLE DOCUMENTS | 1 |
| 3. REQUIREMENTS | 1 |
| 3.1. System description | 1 |
| 3.2. Physical and Performance Characteristics | 2 |
| 3.2.1. Configuration requirements | 2 |
| 3.2.2. Upright frames | 2 |
| 3.2.2.1. Columns | 2 |
| 3.2.2.2. Bearing plates | 3 |
| 3.2.2.3. Diagonal/horizontal bracing | 3 |
| 3.2.3. Shelf beams | 3 |
| 3.2.3.1. Connectors | 4 |
| 3.2.3.2. Shelf beamtocolumn safety lock | 4 |
| 3.2.4. Leveling shims | 4 |
| 3.2.5. Anchoring the structure | 4 |
| 3.2.6. Assembly | 5 |
| 3.2.7. Pallet supports | 5 |
| 3.2.8. wire Decking | 5 |
| 4. QUALITY ASSURANCE PROVISIONS | 5 |
| 4.1. Inspection | 6 |
| 4.2. Tests | 6 |
| 4.3. certifications | 7 |
Fairchild AFB App A - Page i General scope This appendix establishes the minimum performance, design, fabrication, installation, and test requirements for pallet rack in the 92ND LRS Envision Xpress, Building 2163, at Fairchild Air Force Base (AFB), WA. The work shall be completed in accordance with this appendix, the Cover Purchase Description (PD), and Air Force (AF) Drawings BFR1B0-01 and BFR1B0-02. This appendix covers all equipment, materials, and labor necessary to complete installation of the system.
Definitions Bay A storage location in the pallet rack which measures from the front shelf beam to the back shelf beam in depth, and from the inside of the upright frame to the inside of the opposite upright frame in width, and from the top of the shelf beam to the bottom of the next shelf beam above in height. The positions on the top level are considered bays even though they are not fully enclosed. The positions on the floor are considered bays even though there is no bottom shelf beam.
Decking A wire mesh surface spanning the area between two parallel shelf beams for the storage of loose or boxed items.
Pallet rack unit A unit is an assembly of two upright frames and all shelf beams joining those two upright frames; plus pallet supports, decking, or tire supports.
Pallet support Short beam which runs from the front to the back shelf beam used to help support pallets.
APPLICABLE DOCUMENTS
Applicable documents shall be in accordance with Section 2 of the Cover PD and the following documents.
NATIONAL FIRE PROTECTION ASSOCIATION (NFPA)
| NFPA 231C-91 |
| Standard for Rack Storage of Materials |
REQUIREMENTS
System description The pallet racks will be used to store palletized loads and loose items in such a manner to permit placement and removal of any individual load without disturbing any other load. Decking shall be provided to facilitate storage of loose or boxed items. Types “E” and “G” pallet rack shall interface with a rider-reach forklift. The pallet rack system shall be capable of supporting a minimum uniformly distributed load of 6,000 pounds (two 3,000 pound pallets) per bay. The pallet rack system shall be designed for use in seismic conditions in accordance with IBC Section 1613. The pallet rack shall conform to the requirements of the Rack Manufacturers Institute (RMI) June 1990 Specification for the Design, Testing, and Utilization of Industrial Steel Storage Racks.
Physical and Performance Characteristics Configuration requirements The rows of rack units shall be located as shown on AF Drawing BFR1B0-01. Types “E”, “G” and “F” pallet rack shall be located in Area B as designated on the building 2163 key plan shown on AF Drawings BFR1B0-01 and BFR1B0-02. The racks shall be capable of being assembled sidebyside, in a row, using common uprights to support the shelf beams.
Upright frames The upright frames shall be of steel, all welded construction consisting of two columns, diagonal and horizontal braces, and floor bearing plates. Each upright frame shall be capable of supporting fully loaded bays without permanent deformation. The upright frames of like racks shall be interchangeable. Upright frames shall meet the requirements listed in the table below, as a minimum.
| Type “E” |
| Type “F” |
| Type “G” |
| Capacity(lbs) |
| 12,000 |
| 30,000 |
| 18,000 |
| Height (in) |
| 144 |
| 144 |
| 144 |
Safety factor: 1.92 to 1
Columns The columns shall be a continuous channel, box channel, rectangular, square or other formation approved by the Contracting Officer or Technical Representative (COTR). Each column shall have openings to readily accommodate beam connectors, end-to-end, at corresponding heights through the height range of the column openings. The openings at the bottom shall allow for the tops of shelf beams to be installed at six inches above the ground and shall continue upward to the top of the column by 2 inch increments. All openings of each column shall be identical to each other and identical to the openings of all other columns. The position of all corresponding openings of the columns shall not vary more than 3/32 inch as measured from the bottom of the bearing plates. The arrangement of the openings and the fastening devices of the beams shall be such that the tops of the beams are flush, within 3/8 inch, with the top of the column. The width of the column, facing the aisle, shall be a minimum 2 7/8 inches.
Bearing plates The bottom of each column shall have a load bearing plate securely attached. Each bearing plate shall be sufficiently sized to disperse the maximum load imposed by the column. Each bearing plate shall have a minimum of two punched holes to accept minimum 1/2-inch anchor bolts in accordance with 3.2.6.
Diagonal/horizontal bracing The columns shall be braced by horizontal and diagonal braces. Each end of all braces shall be securely welded to the columns. The braces shall not protrude beyond the sides of the columns or obstruct the attachment of the shelf beams to the columns, at any height on the columns. The centerline of the bottom horizontal brace shall not be located more than 12 inches from the bottom of the upright frame, and the centerline of the top horizontal brace shall be located not farther than 12 inches from the top of the upright frame. Other diagonal and horizontal braces shall be uniformly spaced between the top and bottom horizontal braces.
Shelf beams Shelf beams shall be the box or step type. Any openings in the shelf beam construction shall face inward, they shall not face the aisle. The connector shall not be welded to the column. Shelf beamtocolumn connection shall be of the locking type. Each pair of shelf beams shall provide a bay width of 108 inches for Types “E” and “G”; 96 inches for Type “F”, with a uniformly distributed load of 6,000 pounds per bay, there shall be no permanent deformations, and elastic deflections shall not exceed 0.56 percent of the unsupported span, measured with respect to the two ends of the beam. Shelf beams shall be designed with a safety factor of 1.65 to 1. If cross-ties are used they shall be the drop-in type, the use of mechanical fasteners or welding is unacceptable.
Connectors Each end of the shelf beams shall have a multiple prong slipfit or slipjoint type shelf beamtocolumn connector. Separate shelf beams and connectors are unacceptable. The connectors shall be adjustable, allowing the shelf beams to be moved with no more than the use of a soft hammer. The connector shall be capable of transferring all loads and external forces of the shelf beam to the column without failure of the connection, or damage to the column or connector. The prongs shall be of sufficient number, size, and strength to withstand repeated loading and unloading of the rack, and to continually sustain the rated shelf beam load. The prongs shall engage with the openings of the columns in such a manner to prevent lateral rotation of the beam, with each prong contributing to the support of the beam. The prongs shall engage with the openings of the columns to ensure a snug metaltometal fit between the horizontal and vertical load carrying members. The prongs shall be of the same design as the opening.
Shelf beamtocolumn safety lock Each shelf beamtocolumn connection shall have a safety lock which shall lock the shelf beam to the column. The design and manner of construction of the device shall prevent accidental disengagement of the shelf beamtocolumn connection during movement or shifting of the assembled rack unit due to impact to the upright frame or shelf beam from horizontal or vertical directions. The safety locking device shall be an integral, attached part of the shelf beam. The safety lock shall be employed without the use of tools, and no part thereof shall obstruct or restrict the loading or unloading of the racks.
Leveling shims Leveling shims shall be provided with the rack units where necessary. The shims shall have holes corresponding to the holes in the bearing plate, and shall anchor or lock with the bearing plate when the rack is erected. Shims shall be equal in width and length to the bearing plate under which it is installed. Shims shall be of varying thickness so no more than five shims are installed at any point. Slotted shims shall be unacceptable.
Anchoring the structure The rack system shall be anchored to resist all design shear and uplift forces. The rack units shall be designed to be a rigid freestanding structure and shall not be connected to any existing building structure except the floor. Each bearing plate shall be securely anchored to the floor with minimum one 1/2-inch diameter anchor bolt. The minimum embedment of the anchor shall be in accordance with 3.3.2.3 of the Cover PD.
Assembly The assembled pallet rack system shall be rigid, stable, and without deformation or skewing when each bay is loaded to the capacity of the design loads. The pallet rack system shall assemble so that the columns are perpendicular to the beams and parallel to each other. Shelf frames shall be straight and square. All horizontal members shall be level to within 1/8 inch per 10 feet measured over any distance in the rack system.
Pallet supports A minimum of four steel pallet supports per bay shall be installed. The top of each pallet support shall be flush with the tops of the front and back shelf beams to within 1/8 inch. Each pallet support shall be capable of supporting a minimum safe load of 1,500 pounds. All pallet supports shall be flanged at the front and back of the support to inhibit accidental dislodging of pallet supports. Pallet supports shall be designed with a safety factor of 1.65 to 1.
wire Decking Wire mesh decking shall be installed in all bays between all parallel shelf beams and uprights. The decking shall be heavy duty welded steel wire with integral support channels capable of supporting a uniformly distributed load of 6,000 pounds per bay. The decking shall be designed with a safety factor of 1.65 to 1. The decking shall not exhibit permanent deformation and elastic deformations shall not exceed 0.56 percent of the unsupported span. The decking shall be plated or galvanized to protect against corrosion. Decking shall be the appropriate type to interface with the type shelf beam being provided. The ends of the wire mesh decking shall bend over the shelf beam to provide a secure load supporting deck and keep the decking from accidentally disengaging from the shelf beams. Where building columns are located within the pallet racks and where decking is required, the Contractor shall provide a useful decking bay by cutting the decking to fit around the building column.
QUALITY ASSURANCE PROVISIONS
Inspection The system shall be inspected to verify that it meets all the requirements of sections 1, 2, and 3 of this appendix and the Cover PD. These inspections shall be completed as part of the system checkout test and again as a part of the quality conformance test.
Tests The following tests shall be performed on the system as part of the system checkout test and again as a part of the quality conformance test.
| No. |
| Paragraph |
| Description |
3.1. and 3.2.3.
Three pallet bays, picked at random, shall each be loaded with two 3,000-pound pallets (total 6,000 pounds) to ensure the pallet beams are set in place. The loads shall then be removed. The distance from the top of each designated shelf beam to the top of the shelf beam above it shall be measured and recorded as M1. The 3,000-pound pallets shall then be put back into the designated pallet bays. The loads shall be left for a minimum of four continuous hours. The distance from the designated shelf beams to the top of the next shelf beam shall be measured again and recorded as M2. The following formula shall be used to determine the deflection amount:
Types “E” and “G” Deflection = [(M1 - M2) / 108] * 100 Type “F” Deflection = [(M1 - M2) / 96] * 100 If the deflection is greater than 0.56 or if permanent deformation exists when the loads are removed, the system shall fail.
| 3.2.3.2. |
| The shelf-to-column safety lock shall be tested at a minimum of ten random locations. Personnel shall attempt to separate empty shelf beams from the column without disabling the shelftobeam safety lock. If a shelf separates from a column then the system fails the test. |
| 3.1. |
| Test to ensure that the pallet rack system is capable of interfacing with the Raymond model 7400 riderreach forklifts.While testing the vehicles, verify that they interface with the pallet rack by loading and unloading the rack. Check the interface between the pallet rack, the riderreach forklift, and the operator. If normal operations are impeded in any way due to the rack configuration or the rack interferes with the storage and retrieval operations then the system fails the test. |
| 3.2.9. |
| Three decking bays, picked at random, shall each be loaded with two 3,000-pound pallets (total 6,000 pounds) to ensure the decking is set in place. The loads shall then be removed. The distance from the top of the deck to the top of the deck above it shall be measured and recorded as M1. The 3,000-pound pallets shall then be put back into the designated decking bays. The loads shall be left for a minimum of four continuous hours. The distance from the designated decking to the top of the decking above it shall be measured again and recorded as M2. The following formula shall be used to determine the deflection amount: |
Types “E” and “G” Deflection = [(M1 - M2) / 108] * 100
Type “F” Deflection = [(M1 - M2) / 108] * 100
If the deflection is greater than 0.56 or if permanent deformation exists when the loads are removed, the system shall fail.
certifications The Contractor shall provide certification that the following requirements have been met. All certifications shall be provided in accordance with the Contract Data Requirements List.
| No. |
| Paragraph |
| Certifications |
| 3.1. |
| The pallet rack conforms to the requirements the Rack Manufacturers Institute (RMI) June 1990 Specification for the Design, Testing, and Utilization of Industrial Steel Storage Racks. |
| 3.2.2. |
| Each upright frame shall have a minimum safe load capacity of 12,000 pounds and a safety factor of at least 1.92 to 1. |
| 3.2.2.2. |
| The bearing plates are of sufficient size to disperse the maximum load imposed on the column. |
| 3.2.3. |
| All shelf beams are designed for, constructed to, and capable of sustaining the minimum safe load with a safety factor of at least 1.65 to 1 |
TECHNICAL PROPOSAL QUESTIONAIRE
Fairchild AFB App A - Page 8
PALLET RACK
Offeror:
| Solicitation Number: |
| FA8604- |
-R-
| Project Title: |
| Storage Aid System |
| Base: |
| Fairchild AFB WA |
| CSN: |
| BFR1B0 |
Appendix A, Pallet Rack, 31 August 2011
This questionnaire shall be completed by the Offeror. All entries to this questionnaire shall be typed. The questionnaire will be used to determine the Offeror's understanding of the requirements and acceptability of the proposed equipment. Please attach product literature/cut sheets for all equipment detailed in this questionnaire and attach any exceptions to the Purchase Description Appendix or recommendations/design alternatives as detailed below.
Pallet Rack Manufacturer: _______________________________ Model Numbers: ________________________________________________
| Paragraph |
| Characteristics |
| 3.2.1. |
| Dimensions: |
Types “E” and “G” Width of pallet rack unit:___________ inches Depth of pallet rack unit:___________ inches Height of pallet rack unit:__________ inches
Type “F” Width of pallet rack unit:___________ inches Depth of pallet rack unit:___________ inches Height of pallet rack unit:__________ inches
| 3.2.2. |
| Type “E” |
Upright frame part number: ________________________ Minimum capacity of upright frame:__________ pounds based on a maximum shelf spacing of ____ inches Safety factor of: ___________________________ to 1
Type “F” Upright frame part number: ________________________ Minimum capacity of upright frame:__________ pounds based on a maximum shelf spacing of ____ inches Safety factor of: ___________________________ to 1
Type “G” Upright frame part number: ________________________ Minimum capacity of upright frame:__________ pounds based on a maximum shelf spacing of ____ inches Safety factor of: ___________________________ to 1
| 3.2.2.1. |
| Types “E” and “G” |
Width of column facing the aisle: __________ inches Vertical center-center spacing of column openings for shelf beam adjustment:___ inches
Type “F” Width of column facing the aisle: __________ inches Vertical center-center spacing of column openings for shelf beam adjustment:___ inches
| 3.2.2.2. |
| Number of punched holes per bearing plate:________ |
| 3.2.3. |
| Types “E” and “G” |
Shelf beam part number: __________________________
Type of shelf beam: ______________________________
Bay width provided by shelf beam: _________ inches
Minimum capacity per bay: _________________ pounds
Safety factor of: ___________________________ to 1
Will shelf deflection meet the requirements as specified? YES NO
Type “F” Shelf beam part number: __________________________ Type of shelf beam: ______________________________ Bay width provided by shelf beam: _________ inches Minimum capacity per bay: _________________ pounds Safety factor of: ___________________________ to 1 Will shelf deflection meet the requirements as specified? YES NO
| 3.2.3.2. |
| Will shelf beam-to-column safety locks be provided as specified? YES NO |
| 3.2.5. |
| Will leveling shims be provided as specified: |
YES NO
| 3.2.6. |
| Diameter of anchors to be provided:________ inches |
Length of anchors to be provided: _________ inches Number of anchors per bearing plate: _____________
| 3.2.8. |
| Part number of steel pallet supports: ____________ |
Number of steel pallet supports per bay: _________ Capacity of steel pallet supports: ________ pounds
| 3.2.9. |
| Will wire decking be provided as specified: YES NO |
Part number of decking: __________________________ Capacity of decking: _____________________________
EXCEPTIONS/RECOMMENDATIONS/DESIGN ALTERNATIVES
Attach any exceptions taken to the Purchase Description Appendix. Please outline those concerns in detail. Your exceptions will be reviewed to determine acceptability.
Are exceptions taken?
Number of pages attached: ____________________________________
Attach any recommendations or design alternatives you feel may enhance operation, maintainability, or reduce system cost. Your recommendations and design alternatives will be reviewed to determine acceptability.
Are recommendations/design alternatives attached?
Number of pages attached: ____________________________________
We have read the requirements of the Purchase Description Appendix and will comply with all paragraphs as written, with exceptions taken only to those items indicated on the attached exception sheet.
| _____________________________ | ________________________ |
| Offeror's Signature | Date |
TYPED NAME:
COMPANY NAME:
ADDRESS:
PHONE:
FAX:
Pallet Rack - Page 1 of 4
In-Checking Modular Office - Page 1 of Pallet Rack - Page 4 of 4 image1.wmf
File details come from the government source that posted it. Updated .