SAM Q and A Round 3_13 Apr 2026_Signed.pdf

PDF 184 KB Posted

Attached to
F20016 Conference Room 028 Federal contract opportunity
Solicitation number
FA8601-26-Q-0032
Issued by
Department of the Air Force Materiel Command Lifecycle Management Center Wright Patterson Air Force Base

About this file

This is a Questions and Answers document issued by the Air Force Life Cycle Management Center (AFLCMC) at Wright-Patterson Air Force Base in response to contractor inquiries regarding solicitation FA8601-26-Q-0032 (Part 3), dated April 13, 2026.

The document addresses seven clarification questions from contractors regarding workstation furniture specifications and electrical infrastructure requirements. Key clarifications include: (1) panel and worksurface dimensions are both 30 inches deep per the Statement of Work and drawing ID-1; (2) the power pole will be integrated on top of the panel rather than within the open shelves; (3) the facility ceiling height is 8 feet tall; (4) the furniture contractor is responsible for providing the power pole; (5) an existing junction box is available for electrical connection approximately 27 feet away in the opposite direction from the new workstation; (6) dedicated circuit requirements are specified in SOW sections 2.210, 2.211, and 2.212; and (7) the facility is not unionized. The document is signed by Linh Jameson, Contracting Officer at AFLCMC/PZIBA.

View the file

Other files for this federal contract opportunity

Other files attached to F20016 Conference Room 028, newest first.
File Type Posted
Attachment 1 - SOW (Updated)_Redacted.pdf PDF
Attachment 2 - Solicitation (Updated)- FA860126Q0032_Redacted.pdf PDF
SAM Q and A Round 2_02 Apr 2026_Signed.pdf PDF
SAM Q and A_01 Apr 2026_Signed.pdf PDF
ID-1 F20016 RM 028 (Floorplan).pdf PDF
Attachment 2 - Solicitation - FA860126Q0032_Redacted.pdf PDF
Attachment 1 - SOW_Redacted.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DEPARTMENT OF THE AIR FORCE

AIR FORCE LIFE CYCLE MANAGEMENT CENTER

WRIGHT-PATTERSON AIR FORCE BASE OHIO

13 Apr 2026

FROM: AFLCMC/PZIBA

2275 D Street, Area B, Bldg 16 Wright-Patterson AFB OH 45433

SUBJECT: Response to Inquiries Regarding FA8601-26-Q-0032 (Part 3)

QUESTIONS

Question 1:

Based on the attachment 1, WS-1 30"x84", the worksurface required is 30"x84" and that the panels on the image sample, the depth of the worksurface is shorter than the panel. Also, the width of the open shelves is 30" which the image shows full on the panels. I want to understand which option it should go:

a. If worksurface's depth is shorter than the panel, then the setup should be 30"d panels, worksurface should be 24"d.

b. Disregard the image and make the panel and worksurface both have 30"d

ANSWER:

The panel and worksurface both are 30"D per the SOW and drawing ID-1.

Question 2:

The open shelves, 1 side cannot have same width as the panel as the pole will not fit. One side should have around 24"w or less to accommodate the pole. Please verify if this is acceptable.

The SOW does not specify this.

ANSWER:

The power pole will be integrated on top of the panel as shown in the image below.

Question 3:

How high is the ceiling?

ANSWER:

It is 8’ tall.

Question 4:

Who is providing the pole? Will it be you or the electrician?

ANSWER:

The furniture contractor shall provide the power pole.

Question 5:

Is there a place for him to tie the feed into, or will the electrician have to run it all the way back to the nearest electrical box?

ANSWER:

There is an existing junction box in place to feed into.

Question 6:

How far away is the nearest electrical box?

ANSWER:

Approximately 27’ towards the opposite direction of the new workstation.

Question 7:

Will it need dedicated circuits?

ANSWER:

Refer to the SOW 2.210, 2.2,11, 2.212.

Question 7:

Is this a union building?

ANSWER:

No.