Q and A Round 2_5 December 2025.pdf

PDF 598 KB Posted

Attached to
Wind Tunnel Balance Federal contract opportunity
Solicitation number
FA860126Q0004
Issued by
Department of the Air Force Materiel Command Lifecycle Management Center Wright Patterson Air Force Base

About this file

This document is a Questions and Answers (Q&A) response from the Department of the Air Force's Business and Enterprise Systems Directorate at Wright-Patterson Air Force Base, addressing inquiries for solicitation FA8601-26-Q-0004. The document contains two specific technical questions and their corresponding answers. The first question seeks clarification on acceptable sensor models (Delta, Omega85, Omega160) for a wind tunnel balance, with the response indicating that the balance must meet all product/performance requirements from the solicitation and confirming that the 25m cable should run from the wind tunnel balance to the DAQ (Data Acquisition System). The second question pertains to the type of linear interaction matrix, with the government confirming that the 1st order linear interaction matrix is acceptable, despite the vendor suggesting the 2nd order matrix might perform better but at double the cost. The document is signed by Joshua L. Clymer, Contracting Officer from AFLCMC/PZIBA, on 5 December 2025.

View the file

Other files for this federal contract opportunity

Other files attached to Wind Tunnel Balance, newest first.
File Type Posted
Atach 2 - Updated Solicitation.pdf PDF
Q and A_01 December 2025-signed1.pdf PDF
Atach 1 - SOW.pdf PDF
Atach 2 - Solicitation.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DEPARTMENT OF THE AIR FORCE

BUSINESS AND ENTERPRISE SYSTEMS DIRECTORATE

WRIGHT PATTERSON AIR FORCE BASE, OHIO

5 December 2025

FROM: AFLCMC/PZIBA

2275 D Street, Area B, Bldg 16 Wright-Patterson AFB OH 45433

SUBJECT: Response to Inquiries Regarding FA8601-26-Q-0004

QUESTIONS

Question 1:

A. Can you please suggest if the sensors suggested below are acceptable:

Delta: https://www.ati-ia.com/products/ft/ft_models.aspx?id=Delta Omega85: https://www.ati-ia.com/products/ft/ft_models.aspx?id=Omega85 Omega160: https://www.ati-ia.com/products/ft/ft_models.aspx?id=Omega160

B. Can you also confirm if you need the 25m to be from the sensor to the power supply or the power supply to the DAQ?

ANSWER A:

The wind tunnel balance must meet all of the product/performance requirements from the solicitation.

ANSWER B:

The 25 m cable is from the wind tunnel balance to the DAQ.

Question 2:

We have compiled 2 quotes, (one) for 1st order linear interaction matrix and other for 2nd order 6x27 matrix.

Please confirm if the customer need 1st order or 2nd order. We believe that the 2nd order would work.

But it is double the cost of 1st order.

ANSWER:

The 1st order linear interaction matrix is acceptable.

Joshua L. Clymer

Contracting Officer

AFLCMC/PZIBA

2025-12-05T14:29:10-0500
CLYMER.JOSHUA.LEE.1469548445

File details come from the government source that posted it. Updated .