Project Drawings.pdf

PDF 5 MB Posted

Attached to
Reconfiguration of Visualization Laboratory Federal contract opportunity
Solicitation number
FA8601-10-B-0006
Issued by
Department of the Air Force Materiel Command

About this file

Drawings

View the file

Other files for this federal contract opportunity

Other files attached to Reconfiguration of Visualization Laboratory, newest first.
File Type Posted
BID OPENING.docx DOCX document
Map of Twin Base Golf Course.pdf PDF
RECONFIGURE VIZUALIZATION LAB- Site Visit Roster.docx DOCX document
090036_RFI 2- Response.docx DOCX document
090036_RFI 3 Response.docx DOCX document
090036_RFI 1.docx DOCX document
FFP Addendum 2.docx DOCX document
General Wage Decision 30 July_OH 29.docx DOCX document
Project Specifications.pdf PDF
FA8601-10-B-0006 Solicitation.pdf PDF
Drawing Addendum 2_Cable Tray Routing.pdf PDF
FFP Addendum 1.docx DOCX document
Specs Addendum 1_Section 01 33 00.pdf PDF
Specs Addendum 1_Section 01 01 50.pdf PDF
Show all 14

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

01COVER/INDEX SHEET

SCHNEIDER

G001

SCHNEIDER SCHMITZ

COORDINATOR ENGINEERING CHIEF

DATE REVISION BYNO. DATE NO. REVISION BY

C I

V

IL

ENGI

N

E E

R

US AF

PAFB

WRIGHT-PATTERSON AIR FORCE BASE

88TH ABW

OF

DESIGN CHIEF

DATEDRAWNDESIGNED CHECKED

655 Eden Park Drive

Cincinnati, OH 45202-6000

FAX 513 621 6530

WEB www.kzf.com

Architecture | Engineering | Interiors | Planning

W

02.10.10

KZF Project# 5664.07

BUILDING 20248

RECONFIGURE VISUALIZATION LAB, F/20248

WPAFB Project# 090036

100% SUBMITTAL: 10 FEBRUARY 2010

OHIO

DAYTON

OHIO

FAIRBORN

DRAWING INDEX

MECHANICAL

WRIGHT-PATTERSON AIR FORCE BASE, OHIO

VICINITY MAP AREA ’B’ - LOCATION MAP SITE MAP

NO

SHEET SHEET NAME

NO

SHEET SHEET NAME

WPAFB

NOT TO SCALE NOT TO SCALE

NO

SHEET SHEET NAME

GENERAL ELECTRICAL

NO

SHEET SHEET NAME

01 COVER/INDEX SHEET

ARCHITECTURAL ABBREVIATIONS

ARCHITECTURAL SYMBOLS

ARCHITECTURE

ENTRY GATE

SITE MAP

G001 A001

A002

AD01

A101

DEMOLITION PLAN

FLOOR PLAN

A102 CEILING PLAN

A401

A501 WALL TYPES

I001

A601 DOOR SCHEDULE

INTERIOR FINISH SPECIFICATIONS & DRAWING NOTES

I101 INTERIOR FINISH PLAN

I201 FURNITURE PLAN

M001

MD01

ED01

E101

E201

E001

FLOOR PLAN - ELECTRICAL DEMOLITION

ELECTRICAL SYMBOLS

FLOOR PLAN - LIGHTING

FLOOR PLAN - POWER AND SYSTEMSM101 MECHANICAL NEW WORK PLAN

M401

MECHANICAL SYMBOLS

M002 MECHANICAL ABBREVIATIONS

MECHANICAL DEMOLITION PLAN

MECHANICAL ROOM ENLARGED PLAN

INTERIOR ELEVATIONS & SECTIONS

NO

SHEET SHEET NAME

27 F101

FIRE PROTECTION

FIRE PROTECTION PLAN 28

M501 MECHANICAL DETAILS

M601 MECHANICAL SCHEDULES

M701 MECHANICAL CONTROLS

M702 MECHANICAL CONTROLS

M703 MECHANICAL CONTROLS

NO

SHEET SHEET NAME

16 S101 FRAMING PLAN, SECTIONS, AND DETAILS

STRUCTURAL

08 A402

EXISTING CONDITIONS AND PENETRATION DETAILS.

E301

E302

ELECTRICAL SCHEDULES

ELECTRICAL PANELBOARD SCHEDULES

NO

SHEET SHEET NAME

A/V DRAWINGS

A/V01 A/V EQUIPMENT AND POWER DRAWINGS

RECONFIGURE VISUALIZATION LAB FACILITY, F/20248

LEVEL 3

BUILDING 20248,

AREA OF WORK:

WPAFB PROJECT# 090036

I40215

FLOOR TRANSITION DETAILS

INTERIOR ELEVATIONS

I401

E-W RUNWAY BEARING S85° 47’ 30"E 150’ X 7147.70’ (RESERVED RUNWAY FOR USAF MUSEUM-ESSENTIAL LANDING SURFACE) 34

SCHNEIDERSCHNEIDER

ARCHITECTURAL ABBREVIATIONS

SCHMITZ

A001

COORDINATOR ENGINEERING CHIEF

DATE REVISION BYNO. DATE NO. REVISION BY

C I

V

IL

ENGI

N

E E

R

US AF

PAFB

WRIGHT-PATTERSON AIR FORCE BASE

88TH ABW

OF

DESIGN CHIEF

DATEDRAWNDESIGNED CHECKED

655 Eden Park Drive

Cincinnati, OH 45202-6000

FAX 513 621 6530

WEB www.kzf.com

Architecture | Engineering | Interiors | Planning

W

02.10.10

KZF Project# 5664.07

BUILDING 20248

RECONFIGURE VISUALIZATION LAB, F/20248

WPAFB Project# 090036

100% SUBMITTAL: 10 FEBRUARY 2010

NOTE

STANDARD ARCHITECTURAL & STRUCTURAL ABBREVIATIONS

DRAWING

DOVETAIL ANCHOR

DRAIN TILE

DOWNSPOUT

DOOR

DOWN

DAMPPROOFING

DEAD LOAD

DUCTILE IRON PIPE

DIMENSION

DIAGONAL, DIAGRAM

DIAMETER

DRINKING FOUNTAIN

DETAIL, DETENTION

DESIGN

DEPARTMENT

DEMOLITION

DOUBLE

DEEP

CYLINDER

CUBIC

CENTER

CERAMIC TILE

COUNTERSUNK

COURSE

CARPET

CORRUGATED, CORRIDOR

CORNER

COORDINATE

CONTRACTOR

CONTINUOUS

CONSTRUCTION JOINT

CONSTRUCTION

CONNECTION

CONCRETE

COMPOSITION, COMPACTED

COMBINATION

COLUMN

CLEANOUT, COMPANY

CONCRETE MASONRY UNIT

CORRUGATED METAL PIPE

CLEAR, CLEARANCE

CEILING

CLOSET

CHALKBOARD

CONTROL JOINT

CABINET HEATER

CORNER GUARD

CEMENT

CLOSED CIRCUIT TV

CATCH BASIN

CABINET

CENTERLINE

BOTH WAYS

BUILT-UP ROOF

BETWEEN

BASEMENT

BRICK

BEARING

BASE PLATE

BOTTOM

BENCHMARK, BEAM

BLOCKING

BUILDING

BITUMINOUS

BOARD

BOTTOM OF FOOTING

BOTTOM OF CURB

BACK TO BACK

BOTTOM OF

BASELINE

AVERAGE

AUXILIARY

AUDIO VISUAL

ASPHALT

ARCHITECTURAL

APPROXIMATE

APPROVED, APPLIED

ACCESS PANEL

ANODIZED

ALTERNATE

ALUMINUM

AGGREGATE

ABOVE FINISH GRADE

ABOVE FINISH FLOOR

ARCHITECT/ENGINEER

ADJACENT

ADJUSTABLE

ADDITIONAL

AMERICANS WITH DISABILITIES ACT

AREA DRAIN

ACOUSTIC TILE

ACOUSTICAL/AIR CONDITIONING

ABOVE

ANCHOR BOLT

NUMBER OR POUND

AND

AT (THE RATE OF)

DWG

DTA

DT

DS

DR

DN

DMPF

DL

DIP

DIM

DIAG

DIA (OR )

DF

DET

DES

DEPT

DEMO

DBL

D

CYL

CU

CTR

CT

CSK

CRS

CPT

CORR

COR

COORD

CONTR

CONT

CONST JT

CONST

CONN

CONC

COMP

COMB

COL

CO

CMU

CMP

CLR

CLG

CL

CKBD

CJ

CH

CG

CEM

CCTV

CB

CAB

BW

BUR

BTWN

BSMT

BRK

BRG

BP

BOT

BM

BLKG

BLDG

BIT

BD

B/F

B/C

B/B

B/

BL

AVG

AUX

A/V

ASPH

ARCH

APPROX

APPD

AP

ANOD

ALT

AL, ALUM

AGG

AFG

AFF

A/E

ADJT

ADJ

ADDL

ADA

AD

ACT

AC

ABV

AB

QUANTITY

QUARRY TILE

PRESSURE TREATED WOOD

PARTITION

PAINT, POINT

POUNDS PER SQUARE INCH

POUNDS PER SQUARE FOOT

PROPOSED

PRE-FORMED

PAIR

PANEL

PLYWOOD

POUNDS PER LINEAR FOOT

PLUMBING

PLASTER, PLASTIC

PLASTIC LAMINATE

PLATE, PROPERTY LINE

PARKING, PACKAGE

PRE-FINISHED

POUNDS PER CUBIC FOOT

PAVING

PROPERTY LINE

OUNCE

OPPOSITE

OPENING

OPPOSITE HAND

OVERHEAD DOOR

OVERHEAD

OFFICE

OUTSIDE FACE

OUTSIDE DIAMETER

ON CENTER

OUT TO OUT

NOT TO SCALE

NORTH SOUTH

NOISE REDUCTION COEFFICIENT

NOMINAL

NUMBER

NOT IN CONTRACT

NEAR FACE

NOT APPLICABLE

MUNTIN

MULLION

METAL

MOUNTED

MOP RECEPTOR

MOVABLE

MODULAR, MODIFY

MASONRY OPENING

MILLIMETER

MISCELLANEOUS

MINIMUM

MANHOLE

MANUFACTURER

MEZZANINE

MECHANICAL

MAIL BOX

MAXIMUM

MATERIAL

MASONRY

MAINTENANCE

METER

LONG WAY

LIGHTWEIGHT

LIGHTING

LOW POINT

LONG LEG VERTICAL

LONG LEG HORIZONTAL

LIVE LOAD

LEFT HAND

LINEAL FOOT

POUND

LAVATORY

LAMINATE

LABORATORY

ANGLE, LONG, LEFT, LENGTH

KNOCKOUT

KITCHEN

KILO-POUND

KNOCKDOWN

JOINT

JOINT FILLER

JUNCTION BOX

JANITOR

JOIST

INVERT

INTERIOR

INSULATION

INFORMATION

INCLUDE

INCH

INSIDE FACE

INSIDE DIAMETER

QTY

QT

PTWD

PTN

PT

PSI

PSF

PROP

PRF

PR

PNL

PLYWD

PLF

PLBG

PLAS

PLAM

PL

PKG

PFN

PCF

PAV

PL

OZ

OPP

OPNG

OPHD

OHD

OH

OFF

OF

OD

OC

O/O

NTS

NS

NRC

NOM

NO

NIC

NF

N/A

MUNT

MULL

MTL

MTD

MR

MOV

MOD

MO

MM

MISC

MIN

MH

MFR

MEZZ

MECH

MB

MAX

MAT

MAS

MAINT

M

LW

LTWT

LTG

LP

LLV

LLH

LL

LH

LF

LB

LAV

LAM

LAB

L

KO

KIT

KIP

KD

JT

JF

JB

JAN

J

INV

INT

INSUL

INFO

INCL

IN

IF

ID

HARDWOOD

HEADWALL

AIR CONDITIONING

HEATING, VENTILATING &

HEATER

HEATING

HEIGHT

HOUR, HANDRAIL

HIGH POINT

HORIZONTAL

HOLLOW METAL

HARDWARE

HEADER

HARDBOARD

HEAVY DUTY

HANDICAPPED

HOSE BIBB

HIGH

GYPSUM

GYPSUM WALLBOARD

GUTTER

GROUND

GRADE BEAM

GRANULAR

GRADE

GOVERNMENT

GALVANIZED METAL PIPE

GAS METER

GLASS

GENERAL, GENERATOR

GENERAL CONTRACTOR

GALVANIZED

GALLON

GAUGE, GAGE

FIRE VALVE CABINET

FUTURE

FURRING

FOOTING

FOOT

FULL SIZE, FLOOR SINK

FIRE RETARDANT TREATED WOOD

FRAME

FIREPROOFING

FLOOR

FLASHING

FLEXIBLE

FINISH

FIRE HOSE RACK

FIRE HOSE CABINET

FIRE HYDRANT

FINISH FLOOR LINE

EQUIPMENT

FIXTURES, FURNISHINGS &

FINISH FLOOR ELEVATION

FINISH FLOOR, FAR FACE

FIRE EXTINGUISHER CABINET

FIRE EXTINGUISHER

FOUNDATION

FLOOR DRAIN

FACE BRICK, FLOOR BOX

FASTEN(ER)

FIRE ALARM

FACE OF STUDS

FACE OF MASONRY

FACE TO FACE, FLOOR TO FLOOR

FACE OF CONCRETE

FACE OF

EXTERIOR

EXPOSED, EXPANSION

EXHAUST

EXISTING

ELECTRIC WATER COOLER

EAST WEST

EACH WAY, EYE WASH,

ESTIMATE

EYE WASH

EMERGENCY SHOWER &

EMERGENCY SHOWER

EQUIPMENT

EQUAL

ENCLOSE

EMERGENCY

ELEVATOR

ELECTRIC

ELEVATION

EXPANSION JOINT

FINISH SYSTEM

EXTERIOR INSULATING

EACH FACE

EXPANSION BOLT

EACH

EDGE OF PAVEMENT

EDGE OF

HWD

HW

HVAC

HTR

HTG

HT

HR

HP

HORIZ

HM

HDW

HDR

HDBD

HD

HC

HB

H

GYP

GWB

GUT

GRD

GR BM

GRAN

GR

GOVT

GMP

GM

GL

GEN

GC

GALV

GAL

GA

FVC

FUT

FUR

FTG

FT

FS

FRTWD

FR

FP

FLR

FLG

FLEX

FIN

FHR

FHC

FH

FFL

FF&E

FFE

FF

FEC

FE

FDN

FD

FB

FAS

FA

F/S

F/M

F/F

F/C

F/

EXT

EXP

EXH

EXIST

EWC

EW

EST

ESEW

ES

EQMT

EQ

ENCL

EMER

ELEV

ELEC

EL

EJ

EIFS

EF

EB

EA

E/P

E/

TYPICAL

TELEVISION

TOILET

TACKBOARD

THROUGH

THICK

TERRAZZO

TEMPORARY, TEMPERATURE

TELEPHONE

TRENCH DRAIN

TEMPORARY BENCH MARK

TEST BORING

TOP OF WALL

TOP OF SLAB

TOP OF MASONRY

TOP OF JOIST

TOP OF FOOTING

TOP OF COLUMN

TOP OF CONCRETE, TOP OF CURB

TOP OF BEAM

TOP OF

TONGUE & GROOVE

TOP & BOTTOM

TREAD

SYSTEM

SYMMETRY, SYMMETRICAL

SHORT WAY

SUSPENDED, SUSPEND

SUPPLEMENTAL

STRUCTURAL

STORAGE

STEEL JOISTS

STEEL

STANDARD

SOUND TRANSMISSION CLASS

STATION

SERVICE SINK

STAINLESS STEEL

SQUARE

SPECIFICATION

SPECIAL

STANDPIPE

SHEET METAL, SQUARE METER

SLEEVE

SINK

SAW JOINT

SIMILAR

SHEET

SHOWER

STRUCTURAL GLAZED TILE

SQUARE FOOT

SECTION

SOLID CORE WOOD

SCHEDULE

SANITARY

RAILROAD

ROUGH OPENING

ROUND

ROOM

ROOF LEADER

RIGHT HAND

ROOFING

REVISED, REVISION

RESILIENT

REQUIRED

REMOVE, REMOVEABLE

REINFORCED, REINFORCING

REFRIGERATOR

REFERENCE

ROOF DRAIN

REFLECTED CEILING PLAN

REINFORCED CONCRETE PIPE,

RABBET

RESILIENT BASE

RIGHT OF WAY

RADIUS, RISER

YARD, YARD DRAIN

WELDED WIRE FABRIC

WEIGHT

WAINSCOT

WATERSTOP

WATERPROOFING, WORKING POINT

WATER METER

WIND LOAD

WALL HYDRANT, WATER HEATER

WIDE FLANGE, WASH FOUNTAIN

WOOD

WATER CLOSET

WOOD BASE

WITHOUT

WITH

WIDE, WIDTH

VINYL WALL COVERING

VENT THRU ROOF

V-JOINT

VERIFY IN FIELD

VESTIBULE

VERTICAL

VINYL COMPOSITION TILE

VITRIFIED CLAY PIPE

VARIES

SURVEY

UNITED STATES GEOLOGICAL

URINAL

UNLESS NOTED OTHERWISE

UNFINISHED

UNDERWRITERS LABORATORY

UNIT HEATER

UNDERGROUND

UNDERCUT

TYP

TV

TLT

TKBD

THRU

THK

TERR

TEMP

TEL

TD

TBM

TB

T/W

T/S

T/M

T/J

T/FTG

T/COL

T/C

T/BM

T/

T&G

T&B

T

SYS

SYM

SW

SUSP

SUPP

STR

STO

STLJ

STL

STD

STC

STA

SSK

SS

SQ

SPEC

SPC

SP

SM

SLV

SK

SJ

SIM

SHT

SH

SGT

SF

SECT

SCWD

SCH

SAN

RR

RO

RND

RM

RL

RH

RFG

REV

RES

REQD

REM

REINF

REFR

REF

RD

RCP

RBT

RB

R/W

R

YD

WWF

WT

WSCT

WS

WP

WM

WL

WH

WF

WD

WC

WB

W/O

W/

W

VWC

VTR

VJ

VIF

VEST

VERT

VCT

VCP

VAR

USGS

UR

UNO

UNF

UL

UH

UG

UC

TO THE EXTENT APPLICABLE.

ABBREVIATIONS AND APPLIES TO THIS SET OF DRAWINGS

THIS LEGEND IS COMPRISED OF STANDARD SYMBOLS AND

TERRANOVATERRANOVA

03ARCHITECTURAL SYMBOLS

SCHMITZ

A002

COORDINATOR ENGINEERING CHIEF

DATE REVISION BYNO. DATE NO. REVISION BY

C I

V

IL

ENGI

N

E E

R

US AF

PAFB

WRIGHT-PATTERSON AIR FORCE BASE

88TH ABW

OF

DESIGN CHIEF

DATEDRAWNDESIGNED CHECKED

655 Eden Park Drive

Cincinnati, OH 45202-6000

FAX 513 621 6530

WEB www.kzf.com

Architecture | Engineering | Interiors | Planning

W

02.10.10

KZF Project# 5664.07

BUILDING 20248

RECONFIGURE VISUALIZATION LAB, F/20248

WPAFB Project# 090036

100% SUBMITTAL: 10 FEBRUARY 2010

T-1M-1

M-2

S-1(16)

RAMP

DNDN

DNUP

DOWN

RAMP

RAMP UP

RAMP

UP

ROOM

COMM

BB AA A1 B1 C1 D1 E1

REFERENCE SYMBOLS

A2.04

SECTIONS

ELEVATIONS

SECTION NUMBER

DRAWING WHERE SECTION IS SHOWN

DIRECTION OF SECTION CUT

A2.04

A2.04

02 04

A2.04

DETAILS

ROOM NUMBERS

DOOR NUMBERS

INTERIOR PARTITIONS

DIRECTION OF ELEVATION VIEW

ELEVATION NUMBER

DRAWING WHERE ELEVATION IS SHOWN

ELEVATION NUMBERS

DIRECTION OF ELEVATION VIEWS

DRAWING WHERE ELEVATION IS SHOWN

DETAIL NUMBER

DRAWING WHERE DETAIL IS SHOWN

INDICATES FLOOR OR LEVEL

ROOM NUMBER - FIRST DIGIT

TO DOOR SCHEDULE

MULTIPLE DOORS OR BORROWED LITES - REFER

SUBSEQUENT LETTERS REPRESENT ROOMS WITH

CORRESPONDS WITH ROOM WHERE DOOR OCCURS-

DOOR OR BORROWED LITE NUMBER - NUMBER

DIRECTION OF PARTITION CUT

TOILET ROOM ACCESSORIES

MANUAL

TOILET ACCESSORY - REFER TO PROJECT

WINDOW NUMBERS

TO WINDOW SCHEDULE

EXTERIOR WINDOW OPENING NUMBER - REFER

REVISIONS

CLOUD SURROUNDING AREA OF CURRENT REVISION

TITLE BAR INFORMATION

ENTRANCE CANOPY

SECTION

DESCRIPTION OF DETAIL

DETAIL TITLE

NOTE

03SCALE

0 FT21

A1.02

DRAWING(S) WHERE DETAIL IS TAKEN

GRAPHIC SCALE

DETAIL NUMBER

TO THE EXTENT APPLICABLE.

ABBREVIATIONS AND APPLIES TO THIS SET OF DRAWINGS

THIS LEGEND IS COMPRISED OF STANDARD SYMBOLS AND

A

A

UNLESS OTHERWISE INDICATED

NOTE: ALL PARTITIONS ARE TYPE ’A’

INTERIOR PARTITION TYPE

ALL CONSTRUCTION DEBRIS SHALL BE PROMPTLY REMOVED FROM PREMISES.A.

B.

C.

D.

E.

F.

G.

H.

I.

ROOM NUMBERS ARE FOR CONSTRUCTION PURPOSES ONLY.J.

K.

L.

M.

USE ONLY WRITTEN DIMENSIONS; DO NOT SCALE DRAWINGS.N.

O.

P.

Q.

REFER ELECTRICAL DRAWINGS FOR EMERGENCY EXIT SIGNS & LIGHTS.

GENERAL NOTES

OR DETAILED.

NEW WORK SHALL ALIGN WITH & MATCH EXISTING WORK EXCEPT WHERE OTHERWISE DIMENSIONED

CEILINGS SHALL BE FINISHED TO MATCH ADJACENT SURFACES.

FOUNDATIONS, & ACCESSORIES. AFTER REMOVAL, ALL FINISHED SURFACES AT FLOORS, WALLS, &

SUCH REMOVAL SHALL BE COMPLETE, INCLUDING BUT NOT LIMITED TO ANCHORS, HANGERS,

WHEREVER EXISTING EQUIPMENT, PIPING, DUCTS, & SIMILAR ITEMS ARE REQUIRED TO BE REMOVED, DISCONNECTED, OR OTHERWISE MADE SAFE FOR WORK TO PROCEED.

DO NOT COMMENCE DEMOLITION WORK IN ANY AREA UNTIL UTILITIES HAVE BEEN CAPPED, PLUGGED, PATCHWORK SHALL BE FINISHED FLUSH ON BOTH SIDES OF THE OPENING.

& SIMILAR ITEMS WITH MATERIAL APPROPRIATE TO MATCH ADJACENT SURROUNDING MATERIAL.

PATCH OPENINGS, INCLUDING THOSE LEFT BY REMOVAL OF EXISTING DUCTS, CONDUITS, EQUIPMENT, UNLESS OTHERWISE INDICATED OR AS REQUIRED BY HARDWARE.

DOOR FRAMES INDICATED ON PLAN SHALL BE LOCATED MINIMUM 4’’ FROM ADJACENT WALLS

ACOUSTICAL CEILING GRID, OR OTHER NON-STRUCTURAL COMPONENTS.

DIRECTLY FROM STRUCTURE & SHALL NOT BE ATTACHED OR ANCHORED TO EXISTING CONDUITS, SUSPENDED ITEMS SUCH AS DUCTS, PIPES, CONDUITS, & SIMILAR ITEMS SHALL BE SUSPENDED

FINAL SKIM COAT OF GYPSUM BOARD TOPPING COMPOUND.

EXPOSED SURFACE OF PARTITION TO PROVIDE SMOOTH SURFACE FOR NEW FINISH BY APPLYING A

FOR PARTITIONS WHERE EXISTING PANELING OR WALLCOVERING IS NOTED TO BE REMOVED, REPAIR

EXISTING FLOOR, BORDERS, BASE, WAINSCOT, WALLS, & CEILING.

TO MATCH THE TYPE OF MATERIAL, SURFACE FINISH, SIZE, COLOR, & SIMILAR QUALITIES OF THE

TO MATCH EXISTING CONDITIONS. ’’MATCH EXISTING CONDITIONS’’ OR ’’PAINT TO MATCH’’ MEANS

PATCH ADJACENT MATERIALS (FLOORS, WALLS, & CEILINGS) AS REQUIRED BY NEW CONSTRUCTION

AS REQUIRED TO PROVIDE SUITABLE SUBSTRATE BENEATH NEW TILE FLOORS.

OTHERWISE INDICATED. MUD BEDS BENEATH EXISTING TILE FLOORS TO REMAIN. PATCH MUD BEDS

REMOVE FLOORING MATERIAL & BASE IN AREAS SCHEDULED TO RECEIVE NEW FINISHES UNLESS

SUITABLE SUBSTRATE FOR NEW FINISHES.

UNLESS OTHERWISE INDICATED. PATCH EXISTING WALL SURFACES AS REQUIRED TO PROVIDE

REMOVE ALL WALL FINISHES, TRIM, AND CEILINGS IN AREAS SCHEDULED TO RECEIVE NEW FINISHES

R.

MAY AFFECT INTENDED LAYOUT OR DETAILS.

NOTIFY CONTRACTING OFFICER BEFORE BEGINNING CONSTRUCTION OF ANY DISCREPANCIES WHICH

CONCRETE MASONRY UNITS, OR CONCRETE WALLS. CONTRACTOR SHALL VERIFY CONDITIONS &

DIMENSIONS ARE FROM FINISHED FACE OF NEW PARTITIONS, EXISTING PARTITIONS TO REMAIN, S.

CONSTRUCTION ALIGNMENT

A FINISH SURFACE UNLESS NOTED OTHERWISE.

ACROSS VOIDS. THIS ALIGNMENT REFERS TO

ALIGN WITH EXISTING COMPONENTS OR

ELEMENTS OF SIMILAR CONSTRUCTION SHALL

A

BARRIER LOCATIONS MUST BE APPROVED BY OWNER PRIOR TO INSTALLATION.

OCCUPIED AREAS OF BUILDING FROM DEMOLITION & CONSTRUCTION DUST & DEBRIS. DUST

GENERAL CONTRACTOR SHALL CONSTRUCT & MAINTAIN ADEQUATE DUST BARRIERS TO PROTECT

VERIFY IN FIELD.

CEILING HEIGHTS AVERAGE 9’-0" A.F.F. BUT VARY THROUGHOUT PROJECT. CONTRCTOR SHALL

LIFE SAFETY ANALYSIS

A. OCCUPANCY TYPE: B BUSINESS TESTING/RESEARCH)

IBC 2006

B.

OCCUPANT LOAD:

B 100 SF/PERSON

SF/PERSON

S-2 300 SF/PERSON

NONE REQUIREDOCCUPANCY & AREA SEPARATION:

C.

A-3 15

TRAVEL DISTANCE:D.

TOTAL EGRESS PATH300’-0"

COMMON PATH OF TRAVEL100’-0"

DEAD END CORRIDOR50’-0"

SEPARATION IS REQUIRED.

OCCUPANCIES TO THE BUSINESS USE, THEREFORE NO

FLOOR AREA & ARE CONSIDERED TO BE ACCESSORY

THE A-3 OCCUPANCIES ARE LESS THAN 10% OF THE TOTAL

OCC: 6

USE: B

551 S.F.

MEASUREMENT

DISPLAY

306F

OCC: 1

USE: S

166 S.F.

ROOM

MECHANICAL

306C

OCC: 3

USE: B

275 S.F.

LAB 1

306D

Occ: 3 Use: B 289 s.f.

lab 2 306E

OCC: 1

USE: S

63 S.F.

CLOSET

306B

OCC: 19

USE: B

1,908 S.F.

AREA

DEMONSTRATION

OCC: 1

USE: S

69 S.F

CLOSET

ELECTRICAL

305B

OCC: 0

USE: B

52 S.F.

CORRIDOR

EGRESS

305A

USE: A OCC: 20

299 S.F.

FOYER

OCC: 7

USE: B

610 S.F.

PROGRAMMING

306G

USE: B OCC: 0

266 S.F.

CORRIDOR

306A

ALLOWED)

(100’ MAX.

PATH OF TRAVEL

98’ COMMON

BUILDING 20248 IS 100% SPRINKLER PROTECTED.

T.

U.

(DRY LABORATORIES

A+S INCIDENTAL USES (>10%)

OCC: 26

USE: A-3

S.F.

CAB

BATTLE

V.

COORDINATED THROUGH OWNERS REPRESENTATIVE.

CONTRACTOR WORK IS PERMITTED BETWEEN 7AM AND 4 PM. SPECIAL CIRCUMSTANCES MAY BE

937-257-7320.

ABW/CEAR. COORDINATE THIS TURN-IN WITH THE WPAFB 88 ABW/CEAR RADIATION SAFETY BRANCH AT EMERGENCY EXIT SIGNS CONTAINING IONIZING RADIOACTIVE MATERIAL SHALL BE TURNED INTO 88 SUPPRESSION EQUIPMENT CONTAINING IONIZING RADIOACTIVE MATERIAL (SMOKE DETECTORS) AND ANY

NO ASBESTOS-CONTAINING MATERIALS CAN BE INSTALLED DURING THIS PROJECT. ANY FIRE

LANDFILLS. PLEASE CONTACT CEANP AT 257-5527 FOR DETAILS.

CEILING TILES SCHEDULED FOR REMOVAL MAY BE RECYCLABLE, DIVERTING DEMOLITION DEBRIS FROM

TURN-IN.

MANAGER AT 937-257-4769 TO CONFIRM WHAT MATERIALS ARE RECYCLABLE AND TO COORDINATE IN ACCORDANCE WITH WPAFB SPECIFICATION SECTION 01 02 20. CONTACT WPAFB RECYCLING PROGRAM ARE NOT SCHEDULED FOR OFF-SITE RECYCLING CAN BE TURNED INTO THE WPAFB RECYCLING CENTER RECYCLABLE MATERIALS THAT ARE COST EFFECTIVELY SEGREGATED FROM DEMOLITION DEBRIS AND THE WPAFB RECYCLING CENTER IS AVAILABLE FOR CONTRACTOR USE TO REDUCE WASTE DISPOSAL.

SCHNEIDERSCHNEIDER SCHMITZ

AD01

DEMOLITION PLAN

COORDINATOR ENGINEERING CHIEF

DATE REVISION BYNO. DATE NO. REVISION BY

C I

V

IL

ENGI

N

E E

R

US AF

PAFB

WRIGHT-PATTERSON AIR FORCE BASE

88TH ABW

OF

DESIGN CHIEF

DATEDRAWNDESIGNED CHECKED

655 Eden Park Drive

Cincinnati, OH 45202-6000

FAX 513 621 6530

WEB www.kzf.com

Architecture | Engineering | Interiors | Planning

W

02.10.10

KZF Project# 5664.07

BUILDING 20248

RECONFIGURE VISUALIZATION LAB, F/20248

WPAFB Project# 090036

100% SUBMITTAL: 10 FEBRUARY 2010

DNDN

DNUP

DOWN

RAMP

RAMP

UP

ROOM

COMM

TYP.

TYP.

TYP.

TYP.

TYP.

TYP.

11 EX. LEVER AND TRIM SHALL BE REPLACED

TYP.

08 13

BB AA A1 B1 C1 D1 E1

DRAWING NOTES

GENERAL DEMOLITION NOTES

A.

B.

01.

C.

02.

03.

04.

05.

06.

07.

D.

08.

CEILING NOTE

REFER TO DRAWING NOTES.

REMOVE CEILING PANELS AND LAY-IN SUSPENSION SYSTEM.

09.

10.

11.

12.

13.

AND STORE FOR REUSE. REFURBISH TO LIKE NEW CONDITION.

REMOVE EXISTING ENTRY DOORS AND SALVAGE ELECTRONIC ACCESS LOCK

EXISTING DOOR AND HARDWARE TO REMAIN

FINISHES.

PATCH AND REPAIR EXISTING PERIMETER WALL. PREP TO RECEIVE NEW

AND STRUCTURAL DRAWINGS.

PREP TO RECEIVE NEW MECHANICAL LOUVERS. COORDINATE WITH MECHANICAL

REMOVE PORTION OF EXISTING EXTERIOR WALL INCLUDING PRECAST PANEL AND

ACCESS FLOOR TILES.

STANDS SHALL REMAIN. REPAIR AS NECESSARY AND PREPARE TO RECEIVE NEW

REMOVE EXISTING RAISED ACCESS FLOOR TILES ONLY. EXISTING FRAME AND

REMOVE EXISTING DOOR, FRAME, AND HARDWARE.

TO BOTTOM OF CEILING TILE.

REMOVE EXISTING PARTITION WALLS; WALLS RUN FROM TOP OF RAISED FLOOR

NECESSARY.

REMOVE PLUG MOLDS FROM PERIMETER WALL. PATCH AND REPAIR AS

TO OWNER.

CAREFULLY REMOVE CEILING MOUNTED HEAD TRACKER SYSTEM AND DELIVER

ARE TO BE SALVAGED AND REUSED.

REMOVE EXISTING CEILING TILE AND FRAME. ALL ATTACHED SMOKE DETECTORS

CONSTRUCTION. REFER TO ARCHITECTURAL FLOOR PLANS.

REMOVE PORTION OF EXISTING PERIMETER WALL TO ACCOMODATE NEW

REMOVE AND DELIVER TO OWNER. PATCH EXISTING CONCRETE AS NECESSARY

EXISTING LAB EQUIPMENT SECURED TO CEILING STRUCTURE. CAREFULLY

LOCATION IS IN ADJACENT BUILDING WITH LOADING DOCK ACCESS.

CONTRACTOR. COORDINATE WITH OWNER ON STORAGE LOCATION - NOTE THAT

1,500lb TEST TABLE TO BE REMOVED, STORED, AND REINSTALLED BY

937-257-7320.

THIS TURN-IN WITH THE WPAFB 88 ABW/CEAR RADIATION SAFETY BRANCH AT

RADIOACTIVE MATERIAL SHALL BE TURNED INTO 88 ABW/CEAR. COORDINATE

(SMOKE DETECTORS) AND ANY EMERGENCY EXIT SIGNS CONTAINING IONIZING

ANY FIRE SUPPRESSION EQUIPMENT CONTAINING IONIZING RADIOACTIVE MATERIAL

SCOPE OF WORK SHALL BE MAINTIANED.

DURING DEMOLITION AND CONSTRUCTION. ALL EGRESS PATHS OUTSIDE THE

CONTRACTOR SHALL PROVIDE MEANS OF SECURING SCOPE OF WORK AREA

CAREFULLY REMOVED AND HANDED OVER TO OWNER.

START OF DEMOLITION U.N.O. ALL FIXED LABORARTORY EQUIPMENT SHALL BE

OWNER TO REMOVE ALL LOOSE LABORATORY RELATED EQUIPMENT PRIOR TO

ADDITIONAL INFORMATION AND TO SCHEDULE A WALK-THROUGH.

ETC.) MAY BE RECYCLED. CONTACT CEANP AT (937) 257-5527 FOR

WHICH ARE IN GOOD CONDITION (I.E. MOLD, WATER DAMAGE, ADHESIVE FREE

ACOUSTICAL, LAY-IN CEILING PANELS SCHEDULED FOR REMOVAL OR DEMOLITION

COORDINATE TURN-IN.

937-257-4769 TO CONFIRM WHAT MATERIALS ARE RECYCLABLE AND TO

CONTACT WPAFB RECYCLING PROGRAM MANAGER AT

CENTER IN ACCORDANCE WITH WPAFB SPECIFICATION SECTION 01 02 20.

FOR OFF-SITE RECYCLING CAN BE TURNED INTO THE WPAFB RECYCLING

EFFECTIVELY SEGREGATED FROM DEMOLITION DEBRIS AND ARE NOT SCHEDULED

REDUCE WASTE DISPOSAL. RECYCLABLE MATERIALS THAT ARE COST

THE WPAFB RECYCLING CENTER IS AVAILABLE FOR CONTRACTOR USE TO

E.

01DEMOLITION PLAN SCALE

2 4 8FT0 63/16

KEY PLAN

TYP.

TYP.

TYP.

06 06

TYP.

11 11

11 TYP.

11 11 11

11 110303

T-1M-1

M-2

S-1(16) DNDN

DNUP

DOWN

RAMP

ROOM

COMM

BB AA A1 B1 C1 D1 E1

32’-0�" 31’-5"

14’-5"8’-6"2’-0"

4’-0"

6’-0"

A

A

ELEC.

CORRIDOR

PROGRAMING

CLOSET

MECH. ROOM

LAB 2

FOYER

A401

A401

ALIGN

ALIGN

BATTLE CAB

ALIGN

MEASUREMENT

DISPLAY

AREA

DEMONSTRATION

CORRIDOR

EGRESS

D

D

D

A

A

B

D

D

D D

D

AC

EQEQ EQ

8’-0"

B

B

B

B

A L

IG

N

B

B B

E EE

B

B

B

305a b

B

A402

D

A401

A401

A401

0504 BID OPTION A

a

G

D

306F

306C

306B

306A

E b

A

305B 305A

306C 306D 306E 306F

306A

306G

306B

305Aa

DRAWING NOTES

01.

02.

03.

BID OPTION

A.

KNEE-WALL CONSTRUCTION UNDER THE E-GLASS.

TYPE IS CONCEALED ANGLES AT TOP AND BOTTOM. SUBSTITUTE STANDARD

STANDARD GLAZING PANELS TO EXTENTS SHOWN IN BUILDING SECTIONS. FRAME

PROVIDE AND INSTALL ELECTROCHROMIC GLASS (LC TYPE) IN LIEU OF

04.

05.

06.

MECHANICAL DRAWINGS.

EXTRUDED ALUMINUM WALL VENT CENTERED ABOVE DOOR. COORDINATE WITH

DOORS. PAINT TO MATCH NEW DOORS.

REPLACE EXISTING DOOR TRIM AND LEVER TO MATCH NEW ON ADJACENT

ADJACENT EXISTING CONSTRUCTION.

PATCH AND REPAIR EXISTING CORRIDOR WALL. PAINT ENTIRE WALL TO MATCH

FRP BLOCKING AS REQUIRED FOR CFCI VESA MOUNT: 200mmx600mm

GFCI MONITOR: VIEWSONIC MODEL #N4785p, 47" WIDESCREEN MONITOR. PROVIDE

PROVIDE AND INSTALL POWER, DATA, BACKING, AND SUPPORT BRACKET FOR

LOUVER. COORDINATE WITH STRUCTURAL AND MECHANICAL DRAWINGS.

PRECAST EXTERIOR. PAINT NEW STEEL, EXPOSED AT EXTERIOR, TO MATCH

ARCHITECTURAL LOUVERS MODEL #E4JP OR EQUAL. COLOR TO MATCH EXISTING

NEW LOUVER OPENING: PROVIDE AND INSTALL NEW EXTERIOR LOUVER -

SYSTEM PRIOR TO PURCHACE.

WITH MANUFACTURER THAT THE NEW TILE WILL FIT THE EXISTING SUPPORT

BE SUPPORTED BY EXISTING RAISED ACCESS FLOOR FRAME SYSTEM. CONFIRM

AIR DISTRIBUTION ACCESS FLOORING (OR EQUAL) THROUGHOUT. PANELS MUST

PROVIDE AND INSTALL NEW TATE WOOD CORE 5000 (24" SQ) UNDERFLOOR

FLOOR PLAN 01

KEY PLAN

SCALE

2 4 8FT0 63/16

INSTALLATION:

RAISED ACCESS FLOOR PANEL

HATCHING INDICATES AREA OF NEW

9’-2�"

04 0404

SCHNEIDERSCHNEIDER SCHMITZ

A101

FLOOR PLAN

COORDINATOR ENGINEERING CHIEF

DATE REVISION BYNO. DATE NO. REVISION BY

C I

V

IL

ENGI

N

E E

R

US AF

PAFB

WRIGHT-PATTERSON AIR FORCE BASE

88TH ABW

OF

DESIGN CHIEF

DATEDRAWNDESIGNED CHECKED

655 Eden Park Drive

Cincinnati, OH 45202-6000

FAX 513 621 6530

WEB www.kzf.com

Architecture | Engineering | Interiors | Planning

W

02.10.10

KZF Project# 5664.07

BUILDING 20248

RECONFIGURE VISUALIZATION LAB, F/20248

WPAFB Project# 090036

100% SUBMITTAL: 10 FEBRUARY 2010

A102

CEILING PLAN

COORDINATOR ENGINEERING CHIEF

DATE REVISION BYNO. DATE NO. REVISION BY

C I

V

IL

ENGI

N

E E

R

US AF

PAFB

WRIGHT-PATTERSON AIR FORCE BASE

88TH ABW

OF

DESIGN CHIEF

DATEDRAWNDESIGNED CHECKED

655 Eden Park Drive

Cincinnati, OH 45202-6000

FAX 513 621 6530

WEB www.kzf.com

Architecture | Engineering | Interiors | Planning

W

02.10.10

KZF Project# 5664.07

BUILDING 20248

RECONFIGURE VISUALIZATION LAB, F/20248

WPAFB Project# 090036

100% SUBMITTAL: 10 FEBRUARY 2010

DNDN

DNUP

DOWN

RAMP

ROOM

COMM

BB AA A1 B1 C1 D1 E1

DNDN

DNUP

ROOM

COMM

305B 305A

306C 306D 306E 306F

306A

306G

306B

EQ EQ EQ EQ EQ EQ

ALIGN ALIGN

03 03

E Q

E Q

EQ.EQ. EQ.EQ.

EQ.EQ. EQ.EQ.

EQ.18’-0"EQ.EQ. EQ.

E Q

E Q

E Q

E Q

E Q

E Q

E Q

E Q

EQ. EQ.

E Q

E Q

EQ. EQ.

EQ. EQ.

E Q

E Q

EQ. EQ. EQ. EQ.

TPL-1,3

TPL-5,7

TPL-5,7

TPL-9,11

TPL-27,29

TPL-27

DRAWING NOTES

01.

02.

03.

04.

05.

06.

07.

08.

09.

NOTE: LOCATE FIXTURES AS SHOWN WITHIN CEILING GRID.

SHEET A401

CONTINUOUS SOFFIT TO CONCEAL MOTORIZED WINDOW SHADES - REFER TO

CEILING GRID MATCHES RAISED ACCESS FLOOR GRID BELOW.

FRAMED AND PAINTED GYPBD BULKHEAD. PAINT CEILNG CP-1

MECHANICAL, AND DETAIL 01/A402

NEW PENETRATION AT ROOF STRUCTURE - COORDINATE WITH STRUCTURAL,

CP-2

OPEN TO STRUCTURE ABOVE. PAINT ALL STRUCTURE AND INFRASTRUCTURE

OPEN TO STRUCTURE ABOVE

PROVIDE WIDER TRACK TO ELIMINATE GAP

PLAN" LAY-IN TILE WITH SQ. TEGULAR EDGE OR EQUAL.

FORMATIONS ACOUSTIC CLOUD WITH 4" VECTOR EDGE AND "OPTIMA OPEN

NEW DECORATIVE SUSPENDED CEILING TILE SYSTEM - ARMSTRONG

NEW 2x2 ACOUSTIC CEILING TILE AND FRAME.

HITACHI MODEL #CP-X960WA. COORDINATE WITH USER.

PROVIDE POWER, DATA, AND MOUNT FOR GFCI CEILING MOUNTED PROJECTOR.

10.

CEILING PLAN 01SCALE

2 4 8FT0 63/16

KEY PLAN

EXPOSED CEILING

9’-0"

9’-0"

9’-0" 9’-0"

9’-0"

9’-0"

9’-0"

9’-0" 8’-0"8’-0"

9’-6"

9’-6"

9’-6" 9’-6"

9’-6"

9’-6" 9’-6"

9’-6"

9’-6"

7’-6"

A401

INTERIOR ELEVATIONS AND SECTIONS

COORDINATOR ENGINEERING CHIEF

DATE REVISION BYNO. DATE NO. REVISION BY

C I

V

IL

ENGI

N

E E

R

US AF

PAFB

WRIGHT-PATTERSON AIR FORCE BASE

88TH ABW

OF

DESIGN CHIEF

DATEDRAWNDESIGNED CHECKED

655 Eden Park Drive

Cincinnati, OH 45202-6000

FAX 513 621 6530

WEB www.kzf.com

Architecture | Engineering | Interiors | Planning

W

02.10.10

KZF Project# 5664.07

BUILDING 20248

RECONFIGURE VISUALIZATION LAB, F/20248

WPAFB Project# 090036

100% SUBMITTAL: 10 FEBRUARY 2010

EXTRUDED ALUMINUM

CONTINUOUS BLOCKING

(BY OTHERS) MUST BE

LEVEL

SHADECLOTH

IN DOWN

POSITION

REMOVABLE

CLOSURE

(WHITE)

ROLLER TUBE AND

SHADE BAND

REGULAR ROLL

ASSEMBLY (MOTOR

INSIDE TUBE)

HEMBAR IN UP

POSITION WITH

MAX. ROLL UP

DIAMETER UP TO

" [88.9mm]

LC

LC

POCKET INSTALLER NOTE

AND PARALLEL TO WINDOW WALL.

1 - POCKET MUST BE INSTALLED LEVEL

INTERFERE WITH BRACKET LOCATIONS.

2 - POCKET FASTENERS MUST NOT

O P

E N

IN

G

H E

IG

H T

S H

A D

O P

E N

G

H

IG

H T

3"

Ø4"

MIN.

POCKET (WHITE)

060 1 2 3INHALF

FULL

SHADE SOFFIT DETAIL (BASE BID)

0�"4"5�"

BOTTOM OF WINDOW HEAD

ALIGN BOTTOM WITH

GYP. BD. SOFFIT:

030 2 4 6FT1/4

SCALE

SECTION A

0’-0"

Top of Structure

1’-0"

Top of Raised Floor

040 2 4 6FT1/4

SCALE

BATTLE CAB / DEMO AREA GLAZ- BASE BID050 2 4 6FT1/4

SCALE

BATTLE CAB / DEMO AREA GLAZ- BID OPT A

20’-0"20’-0"

CHARACTERISTICS:

WITH THE FOLLOWING

ACTIVATION BY A SWITCH. COMPLY

TO CLEAR UPON ELECTRICAL

INSTANTLY FROM FROSTED WHITE

(LC GLASS) THAT CHANGES

PANELS WITH LIQUID CRYSTAL FLIM

LAMINATED ANNEALED GLASS

SWITCHABLE PRIVACY GLASS: CLEAR

OMIT MOTORIZED SHADES FROM BID.

PROVIDE POWER TO E GLASS AND

0.65%OFF

0.8%ON

SHADING COEFFICIENT

4%OFF

63%ON

DIFFUSED LIGHT TRANSMITTED

.01%OFF

75%ON

SPECUALR LIGHT TRANSMITTED

58%OFF

77%ON

VISABLE LIGHT TRANSMITTANCE:

080 2 4 6FT1/4

SCALE

XXX

ALIGN WITH HEAD OF DOOR

- 5 EQUAL PANES - BUTT GLAZE -

PROVIDE �" ELECTROCHROMIC GLASS

OF DOOR.

5 EQUAL PANES - ALIGN WITH HEAD

TEMPERED GLASS - BUTT GLAZE -

PROVIDE FULL HEIGHT �" CLEAR

A401

BOTTOM OF SHADE SOFFIT. A401

304 305

0 1 2 3FT1/2

SCALE 01

C

1’-3"3’-9"1’-0�"

A401

01/A

ELEVATION 01/A

MONITOR COVE 1 PLAN + ELEV

0 1 2 3FT1/2

SCALEMONITOR COVE 2 PLAN + ELEV 02

1’-1�"3’-9"1’-1�"

A401

02/A

CC D

ELEVATION 02/A

A101

MANUFACTURER - REFER TO SHEET

AND DEPTH WITH FLATSCREEN

CONFIRM RECESS HEIGHT, WIDTH,

A101

MANUFACTURER - REFER TO SHEET

AND DEPTH WITH FLATSCREEN

CONFIRM RECESS HEIGHT, WIDTH,

FLOOR GRID

ALIGN EDGES WITH RAISED ACCESS

A402

EXISTING CONDITIONS AND PENETRATION DETAILS

COORDINATOR ENGINEERING CHIEF

DATE REVISION BYNO. DATE NO. REVISION BY

C I

V

IL

ENGI

N

E E

R

US AF

PAFB

WRIGHT-PATTERSON AIR FORCE BASE

88TH ABW

OF

DESIGN CHIEF

DATEDRAWNDESIGNED CHECKED

655 Eden Park Drive

Cincinnati, OH 45202-6000

FAX 513 621 6530

WEB www.kzf.com

Architecture | Engineering | Interiors | Planning

W

02.10.10

KZF Project# 5664.07

BUILDING 20248

RECONFIGURE VISUALIZATION LAB, F/20248

WPAFB Project# 090036

100% SUBMITTAL: 10 FEBRUARY 2010

040 1 2FT3/4

SCALE

030 1 3INHALFEXISTING COND. - PRECAST

FULL

VERIFICATION OF EXSITING CONDITIONS PRIOR TO WORK ON BUILDING ENVELOPE.

COURTSEY ONLY. THE CONTRACTOR IS RESPONSIBLE FOR PRELIMINARY EXPLORATION AND

NOTE: EXSITING CONDITION DRAWINGS ARE PROVIDED TO THE CONTRACTOR AS A

EXISTING COND. - SECTION @ COL 10

0 1 3INHALF

FULL

2EXTERIOR LOUVER

0 1 3INHALF

FULL

2ROOF PENETRATION DETAIL

EXISTING PRECAST PANEL

COUNTER FLASHING

SILL PANEL WITH DRIP EDGE

CAULK

LOUVER FRAME

STRUCTURAL SUPPORT

STRUCUTRAL SUPPORT

LOUVER FRAME

CAULK

CLIP ANGLE SECURED TO PRECAST PANEL

EXISTING PRECAST PANEL

HEAD DETAIL - JAMB SIM

EXISTING ROOF STRUCTURE

EXISTING INSULATION

EPDM PATCH TO MATCH EXISTING

RECOMMENDATION

COUNTERFLASH PER MANUFACTURERS

MECHANICAL DRAWING

GREENHECK MODEL GPR OR EQUAL. - REFER TO

PREFABRICATED ROOF CURB WITH RAISED CANT -

DRAWINGS

GRAVITY RELIEF HOOD - REFER TO MECHANICAL

DEMOLITION.

DAYS PRIOR TO ROOF

TO OWNERS REPRESENTATIVE (3)

MATERIAL FINDINGS AND REPORT

SAMPLE SITE. SUBMIT HAZARDOUS

PROVIDE A TEMPROARY PATCH AT

CONTRACTOR IS REQUIRED TO

A CERTIFIED ROOFING

TEST FOR HAZARDOUS MATERIAL.

MATERIAL AND INSULATION TO

CORE SAMPLE OF EXISTING ROOF

NOTE: CONTRACTOR SHALL TAKE

SCHNEIDER SCHNEIDER SCHMITZ

A501

WALL TYPES

COORDINATOR ENGINEERING CHIEF

DATE REVISION BYNO. DATE NO. REVISION BY

C I

V

IL

ENGI

N

E E

R

US AF

PAFB

WRIGHT-PATTERSON AIR FORCE BASE

88TH ABW

OF

DESIGN CHIEF

DATEDRAWNDESIGNED CHECKED

655 Eden Park Drive

Cincinnati, OH 45202-6000

FAX 513 621 6530

WEB www.kzf.com

Architecture | Engineering | Interiors | Planning

W

02.10.10

KZF Project# 5664.07

BUILDING 20248

RECONFIGURE VISUALIZATION LAB, F/20248

WPAFB Project# 090036

100% SUBMITTAL: 10 FEBRUARY 2010

SCHEDULED CEILING

CONTINUOUS RUNNER

TOP OF STRUCTURAL SLAB

BOTH SIDES

CONTINUOUS ACOUSTICAL SEALANT

DO NOT FASTEN TO STUDS

SECURED TO STRUCTURE-

CONTINUOUS RUNNER

HUNG MILLWORK/CASEWORK

DOUBLE STUDS AT WALL

HEAD

CEILING

PLAN

�’’ GYPSUM BOARD EACH SIDE

1-1/2

SCALE

0 1FT6 in

�’’ GYPSUM BOARD

AT 16’’ OC

3�’’ x 20 GAGE METAL STUDS

4�’’

02PARTITION TYPE ’B’

1-1/2

SCALE

0 1FT6 in

DO NOT FASTEN TO STUDS

SECURED TO STRUCTURE-

CONTINUOUS RUNNER

SCHEDULED CEILING

CONTINUOUS RUNNER

TOP OF STRUCTURAL SLAB

HUNG MILLWORK/CASEWORK

DOUBLE STUDS AT WALL

BASE BASE

PLAN

CEILING

HEAD

4�’’

DO NOT FASTEN TO STUDS

SECURED TO STRUCTURE-

CONTINUOUS RUNNER

SCHEDULED CEILING

HUNG MILLWORK/CASEWORK

DOUBLE STUDS AT WALL

�’’ GYPSUM BOARD EACH SIDE

AT 16’’ OC

3�’’ x 20 GAGE METAL STUDS

CONTINUOUS RUNNER

TOP OF STRUCTURAL SLAB

1-1/2

SCALE

0 1FT6 in

PARTITIONS WITH ’S’ SUFFIX ONLY

SOUND ATTENUATION INSULATION-

1-1/2

SCALE

0 1FT6 in

DO NOT FASTEN TO STUDS

SECURED TO STRUCTURE-

CONTINUOUS RUNNER

SCHEDULED CEILING

CONTINUOUS RUNNER

TOP OF STRUCTURAL SLAB

HUNG MILLWORK/CASEWORK

DOUBLE STUDS AT WALL

BASE

PLAN

CEILING

HEAD

VARIES

AT 16’’ OC

2�’’ x 20 GAGE METAL STUDS

SEALANT BOTH SIDES

CONTINUOUS ACOUSTICAL

SEALANT BOTH SIDES

CONTINUOUS ACOUSTICAL

SEALANT BOTH SIDES

CONTINUOUS ACOUSTICAL

SEALANT BOTH SIDES

CONTINUOUS ACOUSTICAL

�’’ GYPSUM BOARD BOTH SIDES

PARTITION TYPE ’D’ PARTITION TYPE ’A’PARTITION TYPE ’C’

2�’’

FURRING STRIP

�’’ x 20 GAGE METAL 1

PARTITION TYPE ’E’

MATCH EXISTING

REFER TO PLAN

A601

DOOR SCHEDULE

COORDINATOR ENGINEERING CHIEF

DATE REVISION BYNO. DATE NO. REVISION BY

C I

V

IL

ENGI

N

E E

R

US AF

PAFB

WRIGHT-PATTERSON AIR FORCE BASE

88TH ABW

OF

DESIGN CHIEF

DATEDRAWNDESIGNED CHECKED

655 Eden Park Drive

Cincinnati, OH 45202-6000

FAX 513 621 6530

WEB www.kzf.com

Architecture | Engineering | Interiors | Planning

W

02.10.10

KZF Project# 5664.07

BUILDING 20248

RECONFIGURE VISUALIZATION LAB, F/20248

WPAFB Project# 090036

100% SUBMITTAL: 10 FEBRUARY 2010

A

2’’ 2’’SCHEDULE

REFER

R E

F

R

S C

H E

D U

L E

03FRAME TYPES

0 2 4 6FT1/4

SCALE

02DOOR TYPES

0 2 4 6FT1/4

SCALE

B

DOUBLE STUDS AT JAMB

SECURE TO STUD

STANDARD JAMB ANCHOR-

1 �’’1 �’’

TYPES (WHERE APPLICABLE)

FRAME TYPES FOR GLASS

�’’ GLASS - SEE DOOR &

STOPS ALL AROUND WITH

APPLIED HOLLOW METAL

01SCALE

0 2 in3 6 in4 in

REFER TO PLANS FOR TYPE

GYPSUM BOARD PARTITION-

HEAD / JAMB - H01

D O

F

IS

H

G L

A

T Y

P E

D O

P E

M A

T E

R

IA

L

M A

T E

R

IA

L

F R

A M

P E

H E

A D

J A

M B

F

IR

A

T

IN

G

H

O U

R S

L

IN

T

L

P E

H A

R D

W A

T

R E

M A

R K

S

S

IL

L

M U

L L

IO

N

F R

A

F

IS

H

INDICATED

THICK UNLESS OTHERWISE

NOTE: ALL DOORS 1 �’’

DOOR & OPENING SCHEDULE

DOOR FRAME

DETAILS

N U

M B

E R

D O

O R

SIZE

DOOR SCHEDULE REMARKS

01.

2’’ 2’’SCHEDULE

REFER

R E

F

H E

D U

L E

2’’

SCHEDULE

REFER

(2) 3-0 x 7-0

LEVEL 3

WD F HM

F

F

F

F

F

F

F

F

F

F

F FG

PT

ST

GL

HM

WD

PAINT

STAIN

GLASS

METAL

HOLLOW

WOOD

A

GLAZING

G1. �" THICK, CLEAR, FULLY TEMPERED GLASS

REFER TO INTERIOR DRAWINGS FOR PAINT AND STAIN COLORS.

305b 3-0 x 7-0 1

305a

02.

03.

04.

05.

2’’ 2’’SCHEDULE

REFER

R E

F

H E

D U

L E

W

W306 2-0 x 7-0

G1

G1 B 1

HM PT 3 01,02

(2) 3-0 x 7-0

FG G1 035

HM 6

HM 7

HM

HM

HM BG1 1

G1 W

REFER TO SHEET A401 FOR INFORMATION REGARDING BID OPTION A

TRIM SET TO MATCH NEW HARDWARE.

W/OWNERS SECURITY GROUP.

CONDITION. MODIFY HARDWARE SET AS NECESSARY TO ENSURE PROPER OPERATION. COORDINATE

SALVAGE AND RE-USE EXISTING ELECTRONIC KEYPAD AND LOCK MECHANISM. REFURBISH TO LIKE-NEW

SINGLE DUMMY TRIM ON MAIN CORRIDOR SIDE - DOOR IS EGRESS ONLY.

PAINT TO MATCH EXISTING ADJACENT DOORS

3-0 x 7-0

3-0 x 7-0

3-0 x 7-0

3-0 x 7-0

WD ST HM PT 01 01 - - - -

- HM A PT 01 01 - - - -

WD - ST HM A PT 01 01 - - - -

- ST HM A PT 01 01 - - - -

- ST HM A PT 01 01 - - - -

- ST HM A PT 01 01 - - - -

WD - ST HM A PT 01 01 - - - -

ST HM PT 01 01 - - - -

3-0 x 7-0

3-0 x 7-0

3-0 x 7-0

- ST HM A PT 01 01 - - - -

3-0 x 7-0 WD - ST HM A PT 01 01 - - - -

WD ST HM A PT 01 01 - - - -

306A

306B

306C

306D

306E

306F

306G

3-0 x 7-0

305Aa

305Ab

ST B PT 01 01 - - - -

PT 01 01 - - - - -- -- -

INTERIOR FINISH SPECIFICATIONS & GENERAL NOTES 11

I001

M. KELLY M. KELLY SCHMITZ

FC-1

WC-1

CA-1

CA-2

WP-1

WP-2

RB-1

FR-1

CP-1

PF-1

WALLCOVERING: (WC)

PAINT: (WP)

FLOOR RESILIENT: (FR)

PANEL FABRIC: (PF)

CEILING PAINT: (CP)

CEILING ACOUSTIC: (CA)

REFERENCE THIS DRAWING FOR FINISH SPECIFICATIONS.

REFERENCE ELEVATIONS FOR ALL MILLWORK FINISHES.

ARE TO OCCUR AT CENTERLINE OF DOOR.

ALL CHANGES IN FLOORING BETWEEN ROOMS WITH DOORS

ALL WALLS ARE TO BE PAINTED WP-1 UNLESS NOTED OTHERWISE.

ADJACENT WALL FINISH UNLESS NOTED OTHERWISE.

ALL WALL REVEALS ARE TO BE PAINTED TO MATCH

UNLESS OTHER WISE NOTED.

A SEMI GLOSS FINISH TO MATCH ADJACENT WALL FINISH

ALL ACCESS PANELS OR DIFFUSERS ARE TO BE PAINTED

TO MATCH ADJACENT WALL FINISH, UNLESS NOTED OTHERWISE.

PAINT FACE OF BULKHEAD AND UNDERSIDE OF BULKHEAD

AND BELOW ALL MILLWORK COUNTERS AND CABINETS.

CONTINUE SPECIFIED PAINT AND WALLCOVERINGS ABOVE

UNLESS NOTED OTHERWISE

ALL GYPSUM BOARD CEILINGS ARE TO BE PAINTED CP-1

INSIDE CORNER, UNLESS OTHERWISE NOTED.

ALL TRIM AND BASE TO TERMINATE INTO NEAREST

FINISH UNLESS OTHERWISE NOTED.

A SEMI- GLOSS FINISH TO MATCH ADJACENT WALL

ALL FIRE EXTINGUISHER CABINETS ARE TO BE PAINTED

GENERAL NOTES

A

B

REFERENCE FINISH PLAN FOR FINISHES AND DRAWING NOTES.

REMARKS

F L

O O

R

B A

S E

W A

L L

C E

IL

IN

G

R E

M A

R K

S

FINISH SCHEDULE

R O

O M

N U

M B

E R

R O

DEMONSTRATION AREA

BATTLE CAB

FOYER

306A

306B

306C

306D

306E

CLOSET

LAB 1

LAB 2

CORRIDOR

306F

306G

DISPLAY MEASUREMENT

PROGRAMMING

MECHANICAL ROOM

305A

305B

EGRESS CORRIDOR

ELECTRICAL

ROOM

ALL COLUMNS ARE TO BE PAINTED WP-1, UNLESS NOTED OTHERWISE.

INSTALL METHOD: MONOLITHIC

MULTI LEVEL PATTERN LOOP

COLOR: OPAQUE BLACK/63500

NAME: MIRROR IMAGE TILE/59466

SHAW CONTRACT GROUP

4" HIGH

COLOR: 63 BURNT UMBER

JOHNSONITE

SDT-1

COLOR: CHARCOAL/LIGHT GRAY 66

SIZE: 12X12X1/8

CONDUCTIVE TILE

FLEXCO FLOORING

TYPE II, 25 OZ.

52" WIDE/100% VINYL

COLOR: 030 PEWTER

NAME: PLEAT 395550

MAHARAM

STATIC DISSIPATIVE TILE: (SDT)

WP-3

TO BE PAINTED WP-2, SEMIGLOSS, UNLESS NOTED OTHERWISE.

ALL HOLLOW METAL DOORS, DOOR FRAMES AND SIDELIGHTS

FL-1

FLOOR LAMINATE: (FL)

C

D

E

F

G

H

I

J

K

L

M

N

O

P

CP-2

WP-4

REFERENCE INTERIOR DRAWING I-401 FOR TYPICAL FLOOR TRANSITIONS.

FINISH SPECIFICATIONS

UNBACKED FOR WRAPPED PANELS

NUMBER: 82 / 66" WIDE

PRODUCT LINE: XP

STYLE: RESONANCE 5136

CARNEGIE

BASE RESILIENT: (RB)

AND SPECIFICATION FROM OTHER MANUFCATURERS.

THESE FINISHES ARE THE BASIS OF DESIGN AND ARE NOT INTENED TO LIMIT THE SELECTION OF EQUAL COLORS

FLOOR CARPET: (FC)

DETECTORS OR FIRE ALARM STROBES.

DO NOT PAINT SPRINKLER HEADS, SMOKE AND HEAT

DUCTWORK, ETC. TO MATCH ADJACENT WALL/CEILING FINISH.

PAINT ALL EXPOSED PIPING, CONDUIT, ELECTRICAL DEVICES,

FR-1 RB-1

FC-1 RB-1 CA-1

FC-1 RB-1 WP-4 CA-1

FR-1 RB-1 CA-1

FL-1 RB-1 WP-1 CA-1

FL-1 RB-1 WP-1 CA-1

FR-1 RB-1 WP-1 CA-1

FR-1 RB-1 WP-1 CA-1

RB-1 WP-1 CA-1

FC-1 RB-1 WP-1 CA-1

FR-1 RB-1 WP-1 CA-1

FL-1 RB-1 WP-1 CA-1

SDT-1

1WP-1,3

WP-1,3 CA-2/CP-2

FOR DETAILS

SEE ACCESS FLOORING SPECIFICATIONS

SIZE: 2X2

COLOR: 3607 GREY DUSKSTYLE: PIANO/

FORBO MARMOLEUM

TATE ACCESS FLOOR SYSTEM

SEE SPECIFICATIONS FOR DETAILS

2X2 ACOUSTICALTILE

FINE FISSURED CERAMAGUARD

ARMSTRONG CEILINGS

FOR DETAILS

SEE ACCESS FLOORING SPECIFICATIONS

MR6005 FT / SIZE: 2X2

COLOR: WINTER GRAY MATRIX

STANDRAD LAMINATE OFFERING

TATE ACCESS FLOOR SYSTEM

WP-1 / PF-1

FINISH: SATIN

COLOR: DORIAN GRAY

SW7017

SHERWIN WILLIAMS

FINISH: SATIN

COLOR: NUANCE

SW7049

SHERWIN WILLIAMS

FINISH: SATIN

COLOR: NUANCE

SW7049

SHERWIN WILLIAMS

FINISH: SEMIGLOSS

COLOR: GAUNTLET GRAY

SW7019

SHERWIN WILLIAMS

FINISH: SATIN

COLOR: SASSY GREEN

SW6416

SHERWIN WILLIAMS

FINISH: SATIN

COLOR: DORIAN GRAY

SW7017

SHERWIN WILLIAMS

WD-1

FINISH: 01 CLEAR

VENEER: PLAIN SLICED NATURAL BIRCH

EGGERS INDUSTRIES

WOOD DOOR TO MATCH

WOOD VENEER: (WD)

ALL SCHEDULED WOOD VENEER DOORS TO MATCH WD-1.

1, 2

1, 2

REFERENCE DRAWING I.402 FOR WALL PANEL DESIGN.

SEE SPECIFICATIONS FOR DETAILS

FORMATIONS FLOATING CEILING

ARMSTRONG CEILINGS

COORDINATOR ENGINEERING CHIEF

DATE REVISION BYNO. DATE NO. REVISION BY

C I

V

IL

ENGI

N

E E

R

US AF

PAFB

WRIGHT-PATTERSON AIR FORCE BASE

88TH ABW

OF

DESIGN CHIEF

DATEDRAWNDESIGNED CHECKED

655 Eden Park Drive

Cincinnati, OH 45202-6000

FAX 513 621 6530

WEB www.kzf.com

Architecture | Engineering | Interiors | Planning

W

02.10.10

KZF Project# 5664.07

BUILDING 20248

RECONFIGURE VISUALIZATION LAB, F/20248

INTERIOR FINISH PLAN

I101

M. KELLY M. KELLY SCHMITZ

DRAWING NOTES

REFERENCE DRAWING I-401/B FOR TRANSITION DETAIL FROM CARPET TO RESILIENT FLOORING.

REFERENCE DRAWING I-401/A FOR TRANSITION DETAIL FROM RESILIENT TO STATIC DISSIPATIVE TILE.

REFERENCE DRAWING I-401/D FOR TRANSITION DETAIL FROM RESILIENT TO LAMINATE FLOORING.

04 REFERENCE DRAWING I-401/C FOR TRANSITION DETAIL FROM RESILIENT TO VINYL COMPOSITION FLOORING.

05 PAINT METAL DOOR FRAME TO MATCH ADJACENT, EXISTING, BUILDING STANDARD FRAMES.

06 PAINT WALL TO MATCH OPPOSITE, EXISTING, BUILDING STANDARD WALLS.

07 PAINT HOLLOW METAL DOOR AND FRAME TO MATCH ADJACENT, EXISTING, BUILDING STANDARD DOORS.

305B 305A

306C 306D 306E 306F

306A

306G

306B

PF-1

W C

WP-3

W P

06 06

07 05

DNDN

DNUP

ROOM

COMM

COORDINATOR ENGINEERING CHIEF

DATE REVISION BYNO. DATE NO. REVISION BY

C I

V

IL

ENGI

N

E E

R

US AF

PAFB

WRIGHT-PATTERSON AIR FORCE BASE

88TH ABW

OF

DESIGN CHIEF

DATEDRAWNDESIGNED CHECKED

655 Eden Park Drive

Cincinnati, OH 45202-6000

FAX 513 621 6530

WEB www.kzf.com

Architecture | Engineering | Interiors | Planning

W

02.10.10

KZF Project# 5664.07

BUILDING 20248

RECONFIGURE VISUALIZATION LAB, F/20248

FURNITURE PLAN

I201

M. KELLY M. KELLY SCHMITZ

NOTES

1. REFERENCE FFE PACKAGE FOR FURNITURE SPECS AND DETAILS.

305B 305A

306C 306D 306E 306F

306A

306G

306B

T-1M-1

M-2

S-1(16) DNDN

DNUP

ROOM

COMM

COORDINATOR ENGINEERING CHIEF

DATE REVISION BYNO. DATE NO. REVISION BY

C I

V

IL

ENGI

N

E E

R

US AF

PAFB

WRIGHT-PATTERSON AIR FORCE BASE

88TH ABW

OF

DESIGN CHIEF

DATEDRAWNDESIGNED CHECKED

655 Eden Park Drive

Cincinnati, OH 45202-6000

FAX 513 621 6530

WEB www.kzf.com

Architecture | Engineering | Interiors | Planning

W

02.10.10

KZF Project# 5664.07

BUILDING 20248

RECONFIGURE VISUALIZATION LAB, F/20248

I-401

INTERIOR FLOOR TRANSITION DETAILS

M. KELLY M. KELLY

FLOORING

RESILIENT

CONCRETE SLAB

TILE

STATIC DISSIPATIVE

B. CARPET TO RESILIENT FLOORING

A. RESILIENT FLOORING TO STATIC DISSIPATIVE TILE

CONCRETE SLAB

CARPET

TILE

VINYL COMPOSITION

C. RESILIENT TILE TO VINYL COMPOSITION TILE

D. RESILIENT TILE TO LAMINATE FLOORING

CONCRETE SLAB

TILE

VINYL COMPOSITION

CONCRETE SLAB

LAMINATE FLOOR TILE

LINOLEUM TILE

COLOR TO MATCH RB-1

CTA-XX-N

JOHNSONITE TRANSITION

TILE

LINOLEUM

COLOR TO MATCH RB-1

" RESILIENT� CARPET TO �

JOHNSONITE TRANSITION CTA-XX-C,

FS-XX-DW2. COLOR TO MATCH RB-1.

JOHNSONITE 1" FEATURE STRIP

COLOR TO MATCH RB-1

JOHNSONITE SSR-XX-B

COORDINATOR ENGINEERING CHIEF

DATE REVISION BYNO. DATE NO. REVISION BY

C I

V

IL

ENGI

N

E E

R

US AF

PAFB

WRIGHT-PATTERSON AIR FORCE BASE

88TH ABW

OF

DESIGN CHIEF

DATEDRAWNDESIGNED CHECKED

655 Eden Park Drive

Cincinnati, OH 45202-6000

FAX 513 621 6530

WEB www.kzf.com

Architecture | Engineering | Interiors | Planning

W

02.10.10

KZF Project# 5664.07

BUILDING 20248

RECONFIGURE VISUALIZATION LAB, F/20248

I402

INTERIOR ELEVATIONS

M. KELLY M. KELLY SCHMITZ

COORDINATOR ENGINEERING CHIEF

DATE REVISION BYNO. DATE NO. REVISION BY

C I

V

IL

ENGI

N

E E

R

US AF

PAFB

WRIGHT-PATTERSON AIR FORCE BASE

88TH ABW

OF

DESIGN CHIEF

DATEDRAWNDESIGNED CHECKED

655 Eden Park Drive

Cincinnati, OH 45202-6000

FAX 513 621 6530

WEB www.kzf.com

Architecture | Engineering | Interiors | Planning

W

02.10.10

KZF Project# 5664.07

BUILDING 20248

RECONFIGURE VISUALIZATION LAB, F/20248

WPAFB Project# 090036

100% SUBMITTAL: 10 FEBRUARY 2010

030 2 4 6FT1/4

SCALE

010 2 4 6FT1/4

SCALE

BATTLE CAB / WALL PANEL DESIGN

4’-11" 6’-8�"

20’-0"

2’-0" 2’-0" 6’-0"

020 2 4 6FT1/4

SCALE

DEMONSTRATION ROOM / WALL PANEL DESIGN

4’-0"

A F

F

2’-0"

16’-0"

FABRIC PF-1.

WRAPPED PANEL

NORTH WALL

FABRIC PF-1

WRAPPED PANEL

FABRIC PF-1

WRAPPED PANEL

FABRIC PF-1

WRAPPED PANEL

FABRIC PF-1

WRAPPED PANEL

2’-0"4’-0"

14’-0"

2’-0" 2’-0" 2’-0"

1’-9"

040 2 4 6FT1/4

SCALE

DEMONSTRATION ROOM / WALL PANEL DESIGN

SOUTH WALL

WEST WALL

DEMONSTRATION ROOM / WALL PANEL DESIGN

12’-0"14’-0"

7 5/8 "

2’-0"2’-0"4’-0"

OPEN TO OPEN TO ABOVE

OPEN TO OPEN TO ABOVEOPEN TO OPEN TO ABOVEOPEN TO OPEN TO ABOVE

20’-0"

4’-0"

FABRICPF-1

WRAPPED PANEL

A F

F

A F

F

S101

THIRD FLOOR

01FRAMING PLAN

AHU SUPPORT .

DETAIL 02

HEADER SUPPORT FOR LOUVER OPENING .

SECTION 03

3/8

SCALE

0 2 4FT

MECHANICAL ROOF OPENING .

DETAIL 04

FRAMING PLAN, SECTIONS, AND DETAILS

BUKALA SHARPSHAIR - .

B1

NTS

NTS

NTS

COORDINATOR ENGINEERING CHIEF

DATE REVISION BYNO. DATE NO. REVISION BY

C I

V

IL

ENGI

N

E E

R

US AF

PAFB

WRIGHT-PATTERSON AIR FORCE BASE

88TH ABW

OF

DESIGN CHIEF

DATEDRAWNDESIGNED CHECKED

655 Eden Park Drive

Cincinnati, OH 45202-6000

FAX 513 621 6530

WEB www.kzf.com

Architecture | Engineering | Interiors | Planning

W

02.10.10

KZF Project# 5664.07

BUILDING 20248

RECONFIGURE VISUALIZATION LAB, F/20248

WPAFB Project# 090036

100% SUBMITTAL: 10 FEBRUARY 2010

S101

S101

FOR EXISTING PIPING

ALLOW PASSAGE

STOP BEAMS TO

EXISTING PIPING.

306C

306B

306A

306C

306A

306B

W12x16

W x

W x

W x

W12x16

W x

C6x8.2

C6x8.2

FACE OF AHU

ALIGN WITH

FACE OF AHU

ALIGN WITH

W12x19

PL �"

(2) �" DIA BOLTS

BOTTOM FLANGE

4’-0" OC, MIN (2) PER BEAM,

�" EPOXY ANCHOR AT

1.

FLAT AND STABLE ON FLOOR.

SHIM STEEL ASSEMBLY TO LAY

NOTES:

TENSIONED, AT 11" OC

BOLT FULLY

�" DIA ASTM A325

TO MECHANICAL

OPENING, REFER

6" MIN11"3"

ELEVATION SECTION

ANTI-CORROSION COATING

REINFORCEMENT WITH

EXPOSED ENDS OF

(TYP 4 SIDES) COAT

".DO NOT OVERCUT"

OPENING IN PRECAST

WHEN CUTTING

NOTE:

B1

CONCRETE JOIST TEE

CONCRETE ROOF BEAM

CONCRETE ROOF BEAM

ROOF DECK

OPENING PRIOR TO CUTTING

VERIFY CLEARANCE FOR

WITH MECHANICAL. FIELD

ROOF OPENING. COORDINATE

ANTI-CORROSION COATING

REINFORCEMENT WITH

EXPOSED ENDS OF

(TYP 4 SIDES) COAT

."OR JOISTS

DO NOT CUT BEAMS"

. DO NOT OVERCUT""

OPENING IN PRECAST

WHEN CUTTING ROOF

NOTE:

EXTERIOR INTERIOR

C6x8.2

PL�"x6"

A A

A-A

AWAY FROM WALL

PLATE TO SHED WATER

SLOPE GROUT AT TOP OF

GROUT LEVELING COURSE.

ASTM C1107 NONSHRINK

M001

DRANSMAN FYE NADER

MECHANCIAL SYMBOLS

COORDINATOR ENGINEERING CHIEF

DATE REVISION BYNO. DATE NO. REVISION BY

C I

V

IL

ENGI

N

E E

R

US AF

PAFB

WRIGHT-PATTERSON AIR FORCE BASE

88TH ABW

OF

DESIGN CHIEF

DATEDRAWNDESIGNED CHECKED

655 Eden Park Drive

Cincinnati, OH 45202-6000

FAX 513 621 6530

WEB www.kzf.com

Architecture | Engineering | Interiors | Planning

W

02.10.10

KZF Project# 5664.07

BUILDING 20248

RECONFIGURE VISUALIZATION LAB, F/20248

WPAFB Project# 090036

100% SUBMITTAL: 10 FEBRUARY 2010

A

M3

AHU-1

R2

S1

G

(ABV)

(ABV)

CB-1

MH-1

ABV

ABV.

TW

AAV

MAV

F & T

A

X

A

A

R

ABV.

SG-1

RG-1

BDD

R

20X12

UC �"

20X12 L

C NC

NO

PSD

OR

AD

LD-1

OR

S R

H

T

STANDARD MECHANICAL SYMBOLS

GENERAL SYMBOLS

PLUMBING SYMBOLS

PIPING SYMBOLS HVAC DUCTWORK SYMBOLS

HVAC CONTROL SYMBOLS

HVAC DUCTWORK SYMBOLS (CONT.)

NOTES:

CO

VFD

AFMS

PUMP SUCTION DIFFUSER

45 DEGREE DROP

PIPE ELBOW DOWN

PIPE ELBOW UP

UNION

THERMOMETER WELL

CONCENTRIC REDUCER

ECCENTRIC REDUCER

FLEXIBLE CONNECTION

PLUG VALVE

O.S. & Y VALVE.

QUICK OPENING VALVE

PIPE TEE DOWN

PIPE TEE UP

BLOW-OFF STRAINER

ABBREVIATION OF PIPE CONTENTS

AUTOMATIC FLOW CONTROL VALVE

AUTOMATIC AIR VENT

PUMP

ABBREVIATION OF ITEM

THERMOMETER

PRESSURE GAGE & COCK

MANUAL AIR VENT

(SELF CONTAINED)

TRAP, STEAM W/ TYPE (F & T = FLOAT &

THERMOSTAT; BT = BUCKET, TT = THERMOSTATIC)

PIPE CAP

ALIGNMENT GUIDE (A = TYPE)

ANCHOR (A =TYPE)

EXPANSION JOINT (A = TYPE)

EXPANSION LOOP

FLEXIBLE CONNECTOR

PITCH OF PIPE (R = RISE; D = DROP)

IN DIRECTION OF FLOW

PRESSURE/TEMPERATURE PORT

BALL VALVE

BUTTERFLY VALVE

GATE VALVE

GLOBE VALVE

RELIEF VALVE

BALANCING VALVE

PRESSURE REDUCING VALVE

CHECK VALVE

CALIBRATED BALANCING VALVE

CHECK VALVE W/BALL DRIP

GATE ANGLE VALVE

GLOBE ANGLE VALVE

STRAINER

SUPPLY AIR

RETURN OR EXHAUST AIR

(INCHES W.G.)

DUCT PRESSURE CLASS INDICATOR

UNDER CUT DOOR,WITH SIZE & CFM

LOUVERED DOOR,WITH SIZE & CFM

UNIT HEATER, HORIZONTAL THROW

MANUAL SPLITTER DAMPER

FLEXIBLE DUCT CONNECTION

SUPPLY GRILLE (WALL OR SIDE OF DUCT,

SIMILAR FOR RETURN/EXHAUST GRILLES)

ACCESS DOOR (VERTICAL OF HORIZONTAL)

RECTANGULAR BRANCH TAKE-OFF

RETURN GRILLE (CEILING OR BOTTOM OF DUCT)

CEILING DIFFUSER (CEILING OR BOTTOM OF DUCT)

INTERNAL INSULATION

AUTOMATIC AIR DAMPER

VOLUME DAMPER

BACKDRAFT DAMPER

(200 = CFM QUANTITY)

AIR EXHAUST OR RETURN

(RG OR EG = GRILLE; RR OR ER = REGISTER)

(200 = CFM QUANTITY)

FIRE DAMPER - VERTICAL POSITION

(HORIZONTAL AIR FLOW; AD = ACCESS DOOR)

FIRE DAMPER - HORIZONTAL POSITION

(VERTICAL AIR FLOW; AD = ACCESS DOOR)

(HORIZONTAL AIR FLOW; AD = ACCESS DOOR)

(VERTICAL AIR FLOW; AD = ACCESS DOOR)

SMOKE DAMPER - VERTICAL POSITION

SMOKE DAMPER - HORIZONTAL POSITION

DUCT PITCH IN DIRECTION OF FLOW

(R = RISE; D = DROP)

(DIMENSIONS ARE CLEAR INTERNAL)

AIR SUPPLY OUTLET W/THROW DIRECTION

DUCT SIZE; FIRST NUMBER SHOWN IS

DIMENSION OF SIDE SHOWN

(SG = GRILLE; CD = CEILING DIFFUSER;

SR = REGISTER)

AIR SUPPLY DUCT ELBOW UP

AIR RETURN, OUTSIDE OR EXHAUST DUCT ELBOW UP

AIR SUPPLY DUCT ELBOW DOWN

AIR RETURN, OUTSIDE OR EXHAUST DUCT ELBOW DOWN

LINEAR DIFFUSER (200 = CFM QUANTITY)

UNIT HEATER, VERTICAL THROW

SANITARY WASTE STACK AND VENT NUMBER

KITCHEN EQUIPMENT/LABORATORY EQUIPMENT NUMBER

ROOF LEADER/DOWNSPOUT NUMBER

FLOOR PENETRATION LINE (ISOMETRIC)

VENT THRU ROOF (ISOMETRIC)

PIPE UP TO FIXTURE OR EQUIPMENT INDICATED

WATER ISOMETRIC NUMBER

INTERCEPTOR W/ TYPE (G=GREASE; O=OIL)

BACKWATER VALVE

BACKFLOW PREVENTER (RP=REDUCED PRESSURE;

DC=DUAL CHECK)

HUB DRAIN OUTLET W/ TRAP

FLOOR DRAIN W/ TRAP

RUNNING TRAP W/ CLEANOUT

COLD WATER

HOT WATER

HOT WATER RETURN

VENT PIPING

ROOF DRAIN

ROOF DRAIN W/ SCUPPER DRAIN

PIPING ABOVE FLOOR OR GRADE

(ABV=TYPE; SEE ABBREVIATIONS)

PIPING BELOW FLOOR OR GRADE

(ABV=TYPE; SEE ABBREVIATIONS)

FLOOR OR GRADE CLEANOUT

CATCH BASIN W/ DESIGNATION

MANHOLE W/ DESIGNATION

HOT WATER WITH HEAT TRACE

A

FOR ADDITIONAL CONTROL SYMBOLS & ABBREVIATIONS.

REFER TO HVAC CONTROL SCHEMATIC DRAWINGS

APPLICABLE.

AND APPLIES TO THE SET OF DRAWINGS TO THE EXTENT

THIS LEGEND IS COMPOSED OF STANDARD SYMBOLS

B

SELF OPERATED VALVE

TWO-WAY CONTROL VALVE

THREE-WAY CONTROL VALVE

ROOM THERMOSTAT

HUMIDISTAT

CARBON DIOXIDE SENSOR

MOTOR STARTER

VARIABLE FREQUENCY DRIVE

(C=CLOSED; NC=NORMALLY CLOSED; NO=NORMALLY OPEN)

FAN

STEAM HUMIDIFIER

DUCT CAP

PARALLEL BLADE AIR DAMPER

OPPOSED AIR DAMPER

AIR FLOW MEASURING STATION

DRAWING NOTE HEX

CONNECT TO EXISTING

DETAIL OUTLINE

DETAIL OR SECTION BUBBLE

USE "LETTERS" FOR SECTIONS

USE "NUMBERS" FOR DETAILS

EQUIPMENT MARK NUMBER

SHEET NUMBER WHERE SECTION/DETAIL IS SHOWN

ABBREVIATION OF ITEM

M002

DRANSMAN FYE NADER

MECHANCIAL ABBREVIATIONS

COORDINATOR ENGINEERING CHIEF

DATE REVISION BYNO. DATE NO. REVISION BY

C I

V

IL

ENGI

N

E E

R

US AF

PAFB

WRIGHT-PATTERSON AIR FORCE BASE

88TH ABW

OF

DESIGN CHIEF

DATEDRAWNDESIGNED CHECKED

655 Eden Park Drive

Cincinnati, OH 45202-6000

FAX 513 621 6530

WEB www.kzf.com

Architecture | Engineering | Interiors | Planning

W

02.10.10

KZF Project# 5664.07

BUILDING 20248

RECONFIGURE VISUALIZATION LAB, F/20248

WPAFB Project# 090036

100% SUBMITTAL: 10 FEBRUARY 2010

STANDARD MECHANICAL ABBREVIATIONS

NOTES:

AAD

AAV

A/C

ACCU

ACM

ACU

AD

AF

AFC

AFF

AFG

AHU

AL

ALV

AP

AS

ATV

AV

AW

AWV

AUTOMATIC AIR DAMPER

AUTOMATIC AIR VENT

AIR CONDITIONING

AIR COOLED CONDENSING UNIT

AIR COMPRESSOR

AIR CONDITIONING UNIT

AREA DRAIN

AIR FILTER

ABOVE FINISHED CEILING

ABOVE FINISHED FLOOR

ABOVE FINISHED GRADE

AIR HANDLING UNIT

ALUMINUM

ALARM VALVE

ACCESS PANEL

AIR SEPARATOR

ATMOSPHERIC VENT

AIR VENT

ACID RESISTANT WASTE

ACID RESISTANT WASTE VENT

BC

BD

BDD

BDV

BFP

BH

BHP

BOD

BOP

BP

BT

BOT

BTU

BTUH

BWV

BASEBOARD CONVECTOR

BYPASS DAMPER

BALL DRIP VALVE

BACKFLOW PREVENTER

BOX HYDRANT

BRAKE HORSEPOWER

BOTTOM OF DUCT

BOTTOM OF PIPE

BOOSTER PUMP

BATHTUB

BOTTOM

BRITISH THERMAL UNIT

BRITISH THERMAL UNIT PER HOUR

BACK WATER VALVE

C

CA

CB

CC ****

CC ****

CD ****

CD ****

CDWR

CDWS

CF

CFH

CFM

CH

CI

CIP

CKV

CO

COMP

COND

CR

CS

CSW

CT

CU ****

CU ****

CUH

C

CVR

CENTIGRADE TEMPERATURE

COMPRESSED AIR

CATCH BASIN

COOLING COIL

CABINET CONVECTOR

CEILING DIFFUSER

CONDENSATE DRAIN

CHILLED DRINKING WATER RETURN

CHILLED DRINKING WATER SUPPLY

CHEMICAL FEED

CUBIC FEET PER HOUR

CUBIC FEET PER MINUTE

CHILLER

CHILLED WATER RETURN

CHILLED WATER SUPPLY

CAST IRON

CAST IRON PIPE

CHECK VALVE

CLEANOUT

COMPRESSOR

CONDENSATE

CONDENSATE RETURN (STEAM)

CUP SINK

COLD SOFT WATER

COOLING TOWER

CONDENSING UNIT

COPPER

CABINET UNIT HEATER

COEFFICIENT, VALVE FLOW

CONSTANT VOLUME REHEAT BOX

CONDENSER WATER RETURN

CONDENSER WATER SUPPLY

DB ****

DB ****

DCW

DD

DF

DHW

DHWR

DHWS

DI

DIA

DM

DN

DPI

DPS

DPT

DPR

DPV

DS

DV

DW

DWG

DECIBEL

DOMESTIC COLD WATER

DECK DRAIN

DRINKING FOUNTAIN

DOMESTIC HOT WATER

DOMESTIC HOT WATER RETURN

DOMESTIC HOT WATER SUPPLY

DEIONIZED WATER

DIAMETER

DAMPER MOTOR

DOWN

DIFFERENTIAL PRESSURE INDICATOR

DIFFERENTIAL PRESSURE SWITCH

DIFFERENTIAL PRESSURE TRANSMITTER

DAMPER

DRY PIPE VALVE

DOWNSPOUT

DELUGE VALVE

DISTILLED WATER

DRAWING

EA

EADB

EARH

EAWB

EB

EF

EFF

EG

EH

EJ

EP

ES

ESEW

ESW

ET

EW

EWC

EWT

EXH

EXT

EXHAUST AIR

ENTERING AIR RELATIVE HUMIDITY

ELECTRIC BELL

EXHAUST AIR FAN

EFFICIENCY

EXHAUST AIR GRILLE

EXHAUST HOOD

EXPANSION JOINT

ELECTRIC PNEUMATIC

EMERGENCY SHOWER

EMERGENCY SHOWER & EYE WASH

EXTENDED SIDE WALL SPRINKLER

EXPANSION TANK

EMERGENCY EYE WASH

ELECTRIC WATER COOLER

ENTERING WATER TEMPERATURE

EXHAUST

EXISTING

EXTERNAL

FA

FCU

FD ****

FD ****

FDC

FDV

FDVC

FE

FEC

FH ****

FH ****

FHC

FHR

FHS

FLR

FMD

FOR

FOS

FOV

FPM

FPS

FS

FT

FU

FW

FPWH

FPYW

FAHRENHEIT TEMPERATURE

FIRE ALARM

FAN COIL UNIT

FIRE DAMPER

FLOOR DRAIN

FIRE DEPARTMENT CONNECTION

FIRE DEPARTMENT VALVE

FIRE DEPARTMENT VALVE CABINET

FIRE EXTINGUISHER

FIRE EXTINGUISHER CABINET

FIRE HYDRANT

FUME HOOD

FIRE HOSE CABINET

FIRE HOSE RACK

FIRE HOSE STATION

FLOOR

FLOW MEASURING DEVICE

FUEL OIL RETURN

FUEL OIL SUPPLY

FUEL OIL VENT

FEET PER MINUTE

FEET PER SECOND

FLOW SWITCH

FEET

FIXTURE UNIT

FEED WATER (BOILER)

G

GA

GAL

GALV

GCO

GO

GP

GDH

GPH

GPM

GPR

GAS

GAUGE OR GAGE

GALLON

GALVANIZED

GRADE CLEANOUT

GAS OUTLET

GAS PANEL

GAS DUCT HEATER

GALLONS PER HOUR

GALLONS PER MINUTE

GAS PRESSURE REGULATOR

H **** H ****

HB

HC

HD

HG

HO

HP

HPC

HPS

HR

HS

HSW

HTG

HVU

HWR

HWS

HX

HZ

HUMIDIFIER

HUMIDISTAT

HOSE BIBB

HEATING COIL

HUB DRAIN

HOT GAS (REFRIGERANT)

HUB OUTLET

HORSEPOWER

HIGH PRESSURE CONDENSATE RETURN

HIGH PRESSURE STEAM SUPPLY

HOUR

HOSE STATION

HOT SOFT WATER

HEATING

HEATING & VENTILATING UNIT

HEATING WATER RETURN

HEATING WATER SUPPLY

HEAT EXCHANGER

HERTZ

IA

ID

IE

IFB

IG

IH

IN

INV

ITC

IU

IW

INSTRUMENT COMPRESSED AIR

INSIDE DIAMETER

INVERT ELEVATION

INTEGRAL FACE & BYPASS

INTAKE GRILLE

INTAKE HOOD

INCHES

INVERT

INSPECTOR’S TEST CONNECTION

INDUCTION UNIT

INDIRECT WASTE

JS

KW

KWH

JANITOR’S SINK

KILOWATT

KILOWATT-HOUR

M

MA ****

MA ****

MADB

MARH

MAV

MAWB

MAX

MB

MBD

MBH

MCT

MECH

MH

MIN

MPC

MPS

MR

MTK

MV

MAIN CONTROL AIR SUPPLY

MEDICAL COMPRESSED AIR

MIXED AIR

MIXED AIR RELATIVE HUMIDITY

MANUAL AIR VENT

MAXIMUM

MIXING BOX

MANUAL BALANCING DAMPER

MARKED CEILING TILE

MECHANICAL

MANHOLE

MINIMUM

MEDIUM PRESSURE CONDENSATE RETURN

MEDIUM PRESSURE STEAM SUPPLY

MOP RECEPTOR

MAIN HALON TANK

MEDICAL VACUUM

N

NO

N O

NPSH

NTS

NITROGEN

NORMALLY CLOSED

NORMALLY OPEN

NITROUS OXIDE

NET POSITIVE SUCTION HEAD

NOT TO SCALE

O

OA

OADB

OAI

OARH

OAWB

OBD

OD

OS&Y

OXYGEN

OUTSIDE AIR

OUTSIDE AIR INTAKE

OUTSIDE AIR RELATIVE HUMIDITY

OPPOSED BLADE DAMPER

OUTSIDE DIAMETER

OUTSIDE SCREW & YOKE

PBD

PCV

PE

PF

PH

PI

PIV

PRS

PRV

PS

PSC

PSF

PSI

PSIA

PSIG

PV

PRESSURE GAUGE

PARALLEL BLADE DAMPER

PREHEAT COIL

PRESSURE CONTROL VALVE

PROCESS DRAIN

PNEUMATIC ELECTRIC

PHASE

PRESSURE INDICATOR

POST INDICATOR VALVE

PRESSURE REDUCING STATION

PRESSURE REDUCING VALVE

PRESSURE SWITCH

POST SIAMESE CONNECTION

POUNDS PER SQUARE FOOT

POUNDS PER SQUARE INCH

POUNDS PER SQUARE INCH - ABSOLUTE

POUNDS PER SQUARE INCH - GAUGE

PROCESS VENT

QV QUICK OPENING VALVE

SA ****

SA ****

SADB

SAN

SARH

SAWB

SB

SCH

SCV

SD ****

SD ****

SDA

SF ****

SF ****

SFM

SG

SH

SK

SMC

SP ****

SP ****

SPRK

SQIN

SR

ST ****

ST ****

STM

SV

SW

SUPPLY AIR

SHOCK ABSORBER

SANITARY SEWER

SUPPLY AIR RELATIVE HUMIDITY

SITZ BATH

SPEED CONTROL

SCHEDULE

SECTIONALIZING CONTROL VALVE

SMOKE DETECTOR

SUBSOIL TILE DRAIN

SOUND ATTENUATOR

SUPPLY AIR FAN

SQUARE FOOT

SUPPLY AIR GRILLE

SHOWER

SINK

SIAMESE CONNECTION

STANDPIPE

STATIC PRESSURE

SPRINKLER

SQUARE INCHES

SUPPLY RISER

STAINLESS STEEL

SERVICE SINK

STEAM TRAP

STORM SEWER

STEAM

SAFETY VALVE

SIDE WALL SPRINKLER

T

T&PV

TB

TCP

TCV

TEMP

TG

TK

TOD

TOP

TR

TS ****

TS ****

TV

TW

TYP

THERMOSTAT

TEMPERATURE & PRESSURE RELIEF VALVE

THRUST BLOCK

TEMPERATURE CONTROL PANEL

TEMPERATURE CONTROL VALVE

TRENCH DRAIN

TEMPERATURE

TRANSFER AIR GRILLE

TANK

TOP OF DUCT

TOP OF PIPE

TEMPERED WATER RETURN

TAMPER SWITCH

TEMPERED WATER SUPPLY

TURNING VANES

TREATED WATER

TYPICAL

UC

UG

UH

UR

UV

UN…