MGSU Contruction areas Jun 2026-construction.pdf

PDF 774 KB Posted

Attached to
RFI Notice (Thomas Hall – MGA, Warner Robins, GA)
Solicitation number
FA857926Q0000
Issued by

About this file

This is an architectural drawing for construction needs at Middle Georgia State University's Thomas Hall facility.

The drawing depicts a floor plan renovation project dated December 2024 with modifications noted as of April 3, 2026. Key construction requirements include: installation of 4-inch thick walls with base paint throughout; installation of new sliding glass service windows measuring 11 inches by 3 inches; installation of 6-minute cross-wall vents in existing ceilings; relocation of light switches and electrical fixtures; installation of new doors including a 36-inch door and day gate in an existing hallway; and removal and replacement of ceiling-mounted devices as required. The specification calls for aluminum extruded frame, single pane sliding transaction windows at Level 1 with bullet-resistant Lexan glazing similar to Model 600 security windows with ready access and paint matching existing doors. All new walls extend floor to ceiling with a height of approximately 11 feet 6 inches. The drawing references hollow core wood doors, windowed non-fire-rated wood frames, keyed entry, solid core metal doors, and hollow core metal doors with specific finishes and fire ratings. Room identifications include a Security Office (Storage area), Conference/Multipurpose Room (100), Break Room (101), Collab Room (103), and various work areas. The document is classified as Air Force Drawing No. 98752, Scale 1/8 inch equals 1 foot 0 inch, with D-size specifications and generated under the file path \BUILDINGS\0MGSU\2024MGSU.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Security OfficeStorage

Conference / Multipurpose Room

109 10

A106

A115

Security Office

Storage

Conference / Multipurpose

Room

Break Room / Multipurpose

Room

Collab Room

A106

Collab Room

A

B

C

D

8 7 6 5

IDENTIFYING NO.

PARTS LISTQUANTITY REQUIRED PER DASH NO.

ANGLES

1 DEG

NOMENCLATURE

DIMENSIONS ARE IN INCHES - TOLERANCES ON:

UNLESS OTHERWISE SPECIFIED

.xx±

.xxx±

FRACTIONS

+ 1/16

SYM

DECIMALS

.06 .062 -

AIR FORCE RELEASE

AIR FORCE AUTHENTICATION

ENG

CHK

CODE IDENT

DR

SW

MATERIAL/ SPECIFICATION

U.S. AIR FORCE

DRAWING NO.

98752

AIR FORCE CODE IDENT NO.

D

SIZE

TITLE

UNIT WT ZONE FIND NO.

B

LTR

3 2

APPROVED

REVISIONS

DESCRIPTION DATE

OFSHEET

A

C

D

ENGINEERING DRAWING LAYOUT D

USED ON

*** COMPUTER GENERATED ***

CODE IDENT NO. APPLICATION

CURRENT NEXT ASSEMBLY

FILE --

SCALE

RONNIE FIELDS

THOMAS HALL

STATE UNIVERSITY

MIDDLE GEORGIADEC 2024

\BUILDINGS\0MGSU\2024MGSU

1 1NOTED X

AutoCAD SHX Text

INSTALL 36" DOOR

AutoCAD SHX Text INSTALL 4" THICK WALLS, COVE BASE, PAINT (typ)

AutoCAD SHX Text

INSTALL DOOR

AutoCAD SHX Text

INSTALL NEW SLIDING 36" SECURE SERVICE WINDOW

AutoCAD SHX Text ~21'-7 1/2"

AutoCAD SHX Text ~33'-1"

AutoCAD SHX Text

EXISTING WALL

AutoCAD SHX Text

EXISTING DOOR

AutoCAD SHX Text 11'-3"

AutoCAD SHX Text

EXISTING WINDOWS

AutoCAD SHX Text 12'-4"

AutoCAD SHX Text 7'

AutoCAD SHX Text

INSTALL MIN. (2) ADDITIONAL SPRINKLERS

AutoCAD SHX Text

RETURN DUCT

AutoCAD SHX Text

LIGHT FIXTURE

AutoCAD SHX Text

EXISTING (6) SPRINKLERS

AutoCAD SHX Text 5'

AutoCAD SHX Text 3'

AutoCAD SHX Text

RETURN DUCT

AutoCAD SHX Text

SUPP DUCT

AutoCAD SHX Text

SUPP DUCT

AutoCAD SHX Text

SUPP DUCT

AutoCAD SHX Text

SUPP DUCT

AutoCAD SHX Text

INSTALL 6" MIN. CROSS WALL VENT IN CEILING

AutoCAD SHX Text

INSTALL 6" MIN. CROSS WALL VENT IN CEILING

AutoCAD SHX Text A

AutoCAD SHX Text B

AutoCAD SHX Text M

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text

STORAGE

AutoCAD SHX Text

ELEC

AutoCAD SHX Text

COMM

AutoCAD SHX Text

ELEC

AutoCAD SHX Text window

AutoCAD SHX Text

140 WORK STATIONS

AutoCAD SHX Text window

AutoCAD SHX Text

MULTI

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text Badge

AutoCAD SHX Text Badge

AutoCAD SHX Text Badge

AutoCAD SHX Text Badge

AutoCAD SHX Text Badge

AutoCAD SHX Text Badge

AutoCAD SHX Text glass wall

AutoCAD SHX Text

WORK AREAS

AutoCAD SHX Text 17'-4 1/4"

AutoCAD SHX Text

LIGHT FIXTURE

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text

COMM

AutoCAD SHX Text Badge

AutoCAD SHX Text

INSTALL DAY GATE IN EXISTING HALLWAY

AutoCAD SHX Text ~8'-6"

AutoCAD SHX Text 4'-7 1/8"

AutoCAD SHX Text 4'-4 7/16"

AutoCAD SHX Text 4'-11 3/16"

AutoCAD SHX Text 2'-8 5/8"

AutoCAD SHX Text ADD ADDITIONAL AND/OR RELOCATE ALL CEILING-MOUNTED DEVICES IN THIS AREA AS REQUIRED

AutoCAD SHX Text

INSTALL 6" MIN. CROSS WALL VENT IN CEILING

AutoCAD SHX Text C

AutoCAD SHX Text C

AutoCAD SHX Text REPLACE ONE URINAL W/ TOILET IN EACH OF THE TWO MENS RESTROOMS. EXTEND PARTITIONS AND ADD DOOR PER EACH REPLACEMENT.

AutoCAD SHX Text

MULTI

AutoCAD SHX Text glass wall

AutoCAD SHX Text

MOVE BOTH LIGHT FIXTURES PLAN NORTH 6" TO AVOID NEW WALL

AutoCAD SHX Text

MOVE LIGHT SWITCH TO OTHER SIDE OF DOORWAY

AutoCAD SHX Text

AutoCAD SHX Text E01

AutoCAD SHX Text e01

AutoCAD SHX Text

MIDDLE GA STATE UNIVERSITY - CONSTRUCTION NEEDS

AutoCAD SHX Text

SCALE: " = 1'-0"14" = 1'-0"

AutoCAD SHX Text

AutoCAD SHX Text E01

AutoCAD SHX Text e01

AutoCAD SHX Text

MIDDLE GA STATE UNIVERSITY - KEY PLAN

AutoCAD SHX Text

SCALE: 1/16" = 1'-0"

AutoCAD SHX Text

SCALE: " = 1'-0"316" = 1'-0"

AutoCAD SHX Text

SCALE: " = 1'-0"14" = 1'-0"

AutoCAD SHX Text

NOTE: ALL NEW WALLS ARE FLOOR TO CEILING. FLOOR TO CEILING HEIGHT ~ 11'-6"

AutoCAD SHX Text

NOTE: ADDED 3 APRIL 2026

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

3 APRIL 2026

AutoCAD SHX Text A

AutoCAD SHX Text HOLLOW CORE WOOD DOOR, WINDOWLESS, NON-FIRE-RATED, WOOD FRAME, KEYED ENTRY-SIDE INTERIOR LOCKSET, PAINT TO MATCH EXISTING DOORS

AutoCAD SHX Text B

AutoCAD SHX Text SOLID CORE WOOD DOOR, WINDOWLESS, NON-FIRE-RATED, METAL FRAME, KEYED ENTRY-SIDE INTERIOR LOCKSET, PAINT TO MATCH EXISTING DOORS

AutoCAD SHX Text C

AutoCAD SHX Text SOLID CORE METAL DOOR, WINDOWLESS, NON-FIRE-RATED, METAL FRAME, ENTRY-SIDE PUSHBAR, PAINT TO MATCH EXISTING DOORS, COORDINATE WITH ALARM/ACCESS CONTROL CONTRACTOR FOR FRAME WIRING AND PATHWAYS.

AutoCAD SHX Text M

AutoCAD SHX Text ALUMINUM EXTRUDED FRAME, SINGLE PANE SLIDING TRANSACTION WINDOW, " LEVEL 1 BULLET-RESISTANT 34" LEVEL 1 BULLET-RESISTANT LEXAN GLAZING, SIMILAR TO MODEL 600 SECURITY BY READY ACCESS. PAINT TO MATCH EXISTING DOORS.

AutoCAD SHX Text

AutoCAD SHX Text

26 JUN 2026

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

Sheets and Views
construction

File details come from the government source that posted it. Updated .