Q and A FA857126Q3000 Updated 26 Feb 2026.docx

DOCX document 17 KB Posted

Attached to
BAF 78384 PSC & PWI Cage Material Robins AFB
Solicitation number
FA857126Q3000
Issued by

About this file

This is a Questions and Answers document for solicitation FA857126Q3000, addressing clarifications regarding two cage structures: a Production Support Center (PSC) cage and a Pylon Wing Interface (PWI) cage for Robins Air Force Base.

For the PSC cage, key specifications confirmed include: 2" x 2" x 10 gauge mesh, 10' x 10' doors with padlock hasp locks, 48" deep wire decking (with 42" deep frames), minimum 2500 lbs beam level capacity, a 4' swing door and 10' sliding door both on the 105' face, and a four-sided configuration not against any walls. The cage requires 18 upright frames to accommodate two non-continuous rows of racking at 8' wide sections, with 48" deep wire decking specified. For the PWI cage, also configured as four-sided, the customer already possesses the upright beams and requires only wire decks with no specified beam level capacity notation, though 2500 lbs wire decking capacity is listed. Both cages have mesh specified at 2" x 2" x 10 gauge per DEA standards.

View the file

Other files

File Type Posted
Q and A FA857126Q3000 Updated 05 March 2026 a.docx DOCX document
PD Hughey Revised.pdf PDF
Q and A FA857126Q3000 Updated 05 March 2026.docx DOCX document
PD Hughey Revised.docx DOCX document
Q and A FA857126Q3000 Updated 04 March 2026.docx DOCX document
B125_ PSC Cage.pdf PDF
B125_ PWI Cage.pdf PDF
Q and A FA857126Q3000.docx DOCX document
Provisions and Clauses list 1.pdf PDF
Combo Solicitation PSC and PWI Cage Material.pdf PDF
PD.pdf PDF
Show all 11

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Q&A Responses

1. Can you confirm is mesh on the cage should be 2” x 2” x 10ga OR if it is DEA? Yes, Mesh 2” x 2 X 10ga

2. What is the height of the doors requested. 10’ X 10’

3. Are you needing a padlock hasp lock for the doors? Yes

PSC cage:

1. This shows 42” deep frames with 48” deep wire decking. Should the wire deck be 42”d, or are the frames actually 48”d? The wire decking is 48” because the distance between the frames is 42” and each frame is 3’ thick. 42” + 3” + 3” = 48”

2. There is no beam level capacity noted, but the wire decking capacity is listed at 2500 lbs. Are you looking for 2500 lbs beam level capacity? Beam level 2500 or higher

3. Will the 4’ swing door and the 10’ sliding door both be on the 105’ face of the cage? Yes

4. Is the cage 2,3, or 4 sided? In other words, is the cage in a corner of the room (2 sided), against a back wall (3 sided) or not against any wall (4 sided). 4 sided

PWI cage:

1. There is a requirement for wire decks, but no mention of uprights or beams needed. Do you have a counts and sizes for these? We already have the upright beams for this cage.

2. There is no beam level capacity noted, but the wire decking capacity is listed at 2500 lbs. Are you looking for 2500 lbs beam level capacity? N/A

3. Is the cage 2,3, or 4 sided? In other words, is the cage in a corner of the room (2 sided), against a back wall (3 sided) or not against any wall (4 sided). 4 sided

Assuming they are requesting a continuous run of racking, if there are (16) each 8’ wide sections, you would require 17 frames (uprights), not 18. 18 frames (uprights) would give you (17) each 8’ wide sections.

The run is not continuous it’s two row that why extra frames upright is needed.

Can you let us know which way to quote? Also, it mentions that the frames are 42” deep, but the wire decking is 48” deep. Let us know which depth the customer requires.

Wire decking 48 “ deep.