Q and A FA857126Q3000.docx

DOCX document 16 KB Posted

Attached to
BAF 78384 PSC & PWI Cage Material Robins AFB Federal contract opportunity
Solicitation number
FA857126Q3000
Issued by
Department of the Air Force Materiel Command Air Force Sustainment Center

About this file

This is a Questions and Answers document for Air Force Solicitation FA857126Q3000, addressing clarifications on specifications for two material cage structures required by the Air Force Sustainment Center at Robins AFB, Georgia.

For the Production Support Center (PSC) cage, key clarifications include: mesh specification of 2" x 2" x 10 gauge; door height of 10' x 10'; padlock hasp locks required on doors; wire decking of 48" depth (accounting for 42" frame distance plus 3" frame thickness on each side); beam level capacity of 2,500 pounds or higher; both 4-foot swing door and 10-foot sliding door positioned on the 105-foot face; and the cage configured as a freestanding, four-sided structure. For the Pylon Wing Interface (PWI) cage, the government clarified that upright beams are already in the government's possession, requiring only wire deck supply; beam level capacity specification does not apply; and the cage is also four-sided. Both cages require 2" x 2" x 10 gauge mesh per DEA specifications.

View the file

Other files for this federal contract opportunity

Other files attached to BAF 78384 PSC & PWI Cage Material Robins AFB, newest first.
File Type Posted
Q and A FA857126Q3000 Updated 05 March 2026 a.docx DOCX document
PD Hughey Revised.pdf PDF
PD Hughey Revised.docx DOCX document
Q and A FA857126Q3000 Updated 05 March 2026.docx DOCX document
Q and A FA857126Q3000 Updated 04 March 2026.docx DOCX document
B125_ PSC Cage.pdf PDF
B125_ PWI Cage.pdf PDF
Q and A FA857126Q3000 Updated 26 Feb 2026.docx DOCX document
Combo Solicitation PSC and PWI Cage Material.pdf PDF
PD.pdf PDF
Provisions and Clauses list 1.pdf PDF
Show all 11

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Q&A Responses

1. Can you confirm is mesh on the cage should be 2” x 2” x 10ga OR if it is DEA? Yes, Mesh 2” x 2 X 10ga

2. What is the height of the doors requested. 10’ X 10’

3. Are you needing a padlock hasp lock for the doors? Yes

PSC cage:

1. This shows 42” deep frames with 48” deep wire decking. Should the wire deck be 42”d, or are the frames actually 48”d? The wire decking is 48” because the distance between the frames is 42” and each frame is 3’ thick. 42” + 3” + 3” = 48”

2. There is no beam level capacity noted, but the wire decking capacity is listed at 2500 lbs. Are you looking for 2500 lbs beam level capacity? Beam level 2500 or higher

3. Will the 4’ swing door and the 10’ sliding door both be on the 105’ face of the cage? Yes

4. Is the cage 2,3, or 4 sided? In other words, is the cage in a corner of the room (2 sided), against a back wall (3 sided) or not against any wall (4 sided). 4 sided

PWI cage:

1. There is a requirement for wire decks, but no mention of uprights or beams needed. Do you have a counts and sizes for these? We already have the upright beams for this cage.

2. There is no beam level capacity noted, but the wire decking capacity is listed at 2500 lbs. Are you looking for 2500 lbs beam level capacity? N/A

3. Is the cage 2,3, or 4 sided? In other words, is the cage in a corner of the room (2 sided), against a back wall (3 sided) or not against any wall (4 sided). 4 sided