FA853310R20138______0003.pdf

PDF 38 KB Posted

Attached to
Universal Hydraulic Test Stands Federal contract opportunity
Solicitation number
FA8533-10-R-20138
Issued by
Department of the Air Force Materiel Command Lifecycle Management Center Robins Air Force Base

About this file

Amendment 0003 and Revision 02 to PD

View the file

Other files for this federal contract opportunity

Other files attached to Universal Hydraulic Test Stands, newest first.
File Type Posted
Q As 22 June.pdf PDF
Q As 8 June.pdf PDF
FA853310R20138______0002.pdf PDF
PD_Revision_01_4June2010.pdf PDF
Proposal_Requirements_and_Basis_for_Award_June_2010.pdf PDF
FA853310R20138______0001.pdf PDF
Attachment2.doc DOC document
Attachment4.doc DOC document
EDL_Diesel.pdf PDF
ELINSG001-G002.pdf PDF
Attachment1.doc DOC document
Attachment6.doc DOC document
ELINSE001-E002.pdf PDF
FinalUHTSSOW.pdf PDF
PD07WRGBZOENF10.pdf PDF
Attachment3.doc DOC document
ELINSA001-A003.pdf PDF
EDL_Electric.pdf PDF
ELINSC001-C004.pdf PDF
ELINSB001-B004.pdf PDF
ELINSD001-D005.pdf PDF
Attachment5.doc DOC document
ELINF001.pdf PDF
FA853310R20138_17may.pdf PDF
Show all 24

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT 1. CONTRACT ID CODE

J

2. AMENDMENT/MODIFICATION NO.

FA8533-10-R-20138-0003

3. EFFECTIVE DATE

22 JUN 2010

4. REQUISITION/PURCHASE REQ. NO.

FD2060-10-20138

5. PROJECT NO (If applicable)

6. ISSUED BY CODE

642 CBSG PKBB, MAJOR PROGRAMS

460 RICHARD RAY BLVD STE 200

CML PHN 478 222 1902

ROBINS AFB GA 31098-1813

BUYER: Brandi W. Moody/642 CBSG Brandi.Moody@robins.af.mil Phone: (478) 222- 1910 No Collect Calls

7. ADMINISTERED BY (If other than item 6) CODEFA8533

8. NAME AND ADDRESS OF CONTRACTOR (No., street, county, State and ZIP Code)

CODE

X

9A. AMENDMENT OF SOLICITATION NO.

FA853310R20138

9B. DATED (SEE ITEM 11)

10A. MODIFICATION OF CONTRACT/ORDER NO.

10B. DATED (SEE ITEM 13)

11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS

The above numbered solicitation is amended as set forth in item 14. The hour and date specified for receipt of Offers is extended, is not extended. Offers must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended, by one of the following methods. ( a ) By completing Items 8 and 15, and returning copies of the amendment; ( b ) By acknowledging receipt of this amendment on each copy of the offer submitted; or ( c ) By separate letter or telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.

12. ACCOUNTING AND APPROPRIATION DATA (If required)

13. THIS APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS

IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.

A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE CONTRACT ORDER NO. IN ITEM 10A.

B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation date, etc.) SET FORTH IN ITEM 14, PURSUANT TO AUTHORITY OF FAR 43.103(b).

C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:

D. OTHER (Specify type of modification and authority)

E. IMPORTANT: Contractor is not, is required to sign this document and return 1 copies to the issuing office.

14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)

15A. NAME AND TITLE OF SIGNER (Type or print)

15B. CONTRACTOR/OFFEROR

BY ________________________________________________________

(Signature of person authorized to sign)

15C. DATE SIGNED

16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)

16B. UNITED STATES OF AMERICA

BY ____________________________________________________

(Signature of Contracting Officer)

16C. DATE SIGNED

FACILITY CODE

NSN 7540-01-152-8070

PREVIOUS EDITION UNUSABLE

30-105 STANDARD FORM 30 (REV. 10-83)

PRESCRIBED BY GSA

FAR (48 CFR) 53.243

X

X X

Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.

Amendment/Modification FA8533-10-R-20138-0003

Continuation of block 14. DESCRIPTION OF AMENDMENT/MODIFICATION

The purpose of this amendment is as follows:

1. To incorporate the Purchase Description Revision 02, dated 21 June 2010 into Purchase Description (PD) PD07WRGBZOENF10, dated 29 October 2009.

2. There are no other changes to the RFP as a result of this amendment.

Request for Proposal FA8533-10-R-20138-0003

Request for Proposal FA8533-10-R-20138-0003

LIST OF DOCUMENTS, EXHIBITS OR ATTACHMENTS

Form Number Description/File Name Date Number of Pages Revision 02 to PD07WRGBZOENF10.pdf 21JUN2010 2

PURCHASE DESCRIPTION PD07WRGBZOENF10

Revision 02, dated 21 June 2010

PD07WRGBZOENF10, Universal Hydraulic Test Stand (UHTS) - Dual system, trailer-mounted, dated 29 October 2009, is revised as indicated in the paragraphs below:

1. All references to MIL-STD-810F in purchase description PD07WRGBZOENF10 are hereby replaced with MIL-STD-810G.

2. Remove paragraph 3.14 Housing

, in PD07WRGBZOENF10, dated 29 October 2009, and replace it with the following:

3.14 Housing

. The components of the UHTS shall be mounted and assembled on a trailer and covered with a weather-resistant housing. The complete UHTS shall meet the requirements of SAE AS8090 type 1 class 2 mobility. The structures shall be designed to provide a static safety factor of 3 and dynamic safety factor of 2, based on yield strength of the housing material, when loaded under the worst-case scenarios. The UHTS components and control panel shall be completely enclosed and protected by the weather-resistant housing. The housing shall be designed to support a 200 pound weight evenly distributed over a rectangular area that is 4.5 inches long by 5 inches wide, and shall prevent damage or permanent distortion as a result of the weight being applied in any location on top of the UHTS. The housing shall be adequately braced to prevent damage or permanent distortion as a result of being pushed manually. The housing shall be adequately braced to prevent distortion or excessive vibration during handling and operation of the stand or handling of the housing while being removed from the stand. Drip pan(s) to catch spilled fluids shall be provided. Metal hooks or a hanger shall be provided on the exterior of the housing to permit temporary storage of the pressure hoses. Hooks shall be designed to permit flat positioning of the hooks against the housing when not in use. The hooks and points of attachment to the housing should be of such strength that no permanent deformation of hooks or support occurs when the hoses, filled with fluid, are stored. The housing shall have a heater hose adapter in accordance with AF drawing 7347073 to direct heat from a ground heater onto the engine for cold weather starting. The heater opening shall be closed with an acoustically treated cap when not in use. The housing shall be provided with access doors to permit access for operating and servicing the stand. The doors shall be free from binding and easy to operate with one hand. Provisions shall be incorporated to rigidly secure the doors in the fully open and fully closed position. The housing shall be easily removable by no more than two personnel by actuating not more than 16 quick acting fasteners and lifting or sliding the housing off the stand. Handles shall be provided for this purpose. The lengths and width of the UHTS and housing shall be not less than the trailer frame.

3. Remove existing paragraph 3.11.5 Fluid filtration

, and replace it with the following:

3.11.5 Fluid filtration. High and low pressure filtration systems shall be incorporated for each system. These systems shall consist of the filter element housing, filter element, and differential pressure indicator. The filter units shall be an in-line type with replaceable elements.

The filter units shall have features necessary to promote ease of inspection, servicing and replacement of parts and elements. The filter element housing shall be capable of withstanding a minimum proof pressure of 2.5 times the operating pressure and a minimum burst pressure of

4.00 times the maximum operating pressure under all conditions, environments, and hydraulic fluids specified. The flow entering the housing shall not impinge on the filter element. The filter element and housing for the high pressure system shall be certified and acceptance qualified to MIL-PRF-81836. The filter element and housing for low pressure systems shall be certified and acceptance qualified to MIL-F-5504 or commercial equivalent. The filter assemblies shall be capable of withstanding 1000 hours of operation at 275° F fluid and ambient temperature with no degradation in performance. When the pressure drop across the high pressure filter unit exceeds the pre-determined differential pressure of 100 +/- 15 psi (adjustable), an alarm indication, both audio and visual, shall be activated. Once actuated, this indicator shall remain activated until manually reset. Indicators shall be mounted on the stand control panel to simultaneously indicate the pressure on both sides of the filter in the fill system and boost pump systems. The indicators shall have a range from 0 to 200 psi.

4. Remove existing paragraph 3.17.1 Electronic motor

3.17.1 Electronic motor

. The UHTS type II electric motor shall be a 3 phase Alternating Current drip-proof guarded medium machine designed, constructed, wired, and installed in accordance with National Electrical Contractors Association (NEMA) Motors and Generators (MG 1) and NEMA Safety Standard for Construction and Guide for Selection, Installation and Use of Electric Motors and Generators (MG 2) when operating from a 380 volts/3 phase/50 Hz (European strapping configuration) and 480 volts/3 phase/60 Hz current (U.S. strapping configuration).

5. Remove existing paragraph 3.17.3.2 Input voltage and frequency

, and replace it with the following:

3.17.3.2. Input voltage and frequency

60 (± 5%)Hz: 480 (± 10%) VAC

. The UHTS type II shall be capable of accepting inputs from different voltage systems. The UHTS unit shall be set at the factory to accept a 480 VAC input.

50 (± 5%)Hz: 380 (±10 %) VAC

6. Remove existing paragraph 4.7.7 Electrical power

4.7.7 Electrical power

. For the type II stands, run on 480 volts/3 ph/60 Hz and record the full load amperage and start up amperage. For the type II stands, in the alternate power testing configuration under 4.8.8.3, run on 380 volts/3 ph/50 Hz and record the full load amperage and start up amperage.

Revision 02 to PD07WRGBZOENF10.pdf
4.7.7 Electrical power. For the type II stands, run on 480 volts/3 ph/60 Hz and record the full load amperage and start up amperage. For the type II stands, in the alternate power testing configuration under 4.8.8.3, run on 380 volts/3 ph/50 Hz and record the full load amperage and start up amperage.

File details come from the government source that posted it. Updated .