2d Rd of Questions and Answers - FA8251-21-Q-0004-0001.docx

DOCX document 20 KB Posted

Attached to
F-16 A/B HUD - PDU Repairs
Solicitation number
FA8251-21-Q-0004
Issued by

View the file

Other files

File Type Posted
FA825221Q0004 - Question Set 3.docx DOCX document
FA825121Q0004_______0002.pdf PDF
PWS_HUD_PDU_.docx DOCX document
FA825121Q0004_______0001.pdf PDF
Questions and Answers- FA8251-21-Q-0004.pdf PDF
Combined_CDRLs_A001_A002_A004_B001.pdf PDF
CDRL_B002-IUID_Plan.pdf PDF
Transportation.pdf PDF
Packaging.pdf PDF
RQR.pdf PDF
PWS HUD PDU FD20202100171.pdf PDF
Special_Packing_Instructions_1-7.pdf PDF
WAGE_DET.pdf PDF
CAV_Instructions.pdf PDF
FA825121Q0004.pdf PDF
Show all 15

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

2nd round of Answered Questions 6 May RFQ Close Date 11 May/COB

1. CLIN 0001 BER CLIN - the NSN is incorrect and alternate part number 16VE017001-13 needs to be added. NSN is correct on the PR, including part number 16VE017001-13 – I did add it as an alternate on the PWS though they are the same HUD – updated PWS attached. Corrected in Amendment 0001 by contracting.

1. DATA CLIN 0003 – A003 Government Property Report is missing. I concurred to have this taken out of the recurring data CLIN CAVAF (Recurring Data CAVAF End Item Report A001 Contract Depot Maintenance Monthly Production Report A002 Government, Property Inventory Report A003 Maintenance Data Collection Report A004) I removed it from the PWS.

1. DATA CLINs 0003 & 0004 – Inspection/Acceptance Report states “Receiving Report Required”, however Block 7 of some of the CDRLS requires a letter of transmittal (LT) not (DD). Please correct DATA CLINS Inspection/Acceptance Report to read “IAW DD1423-1. Correct, PR states IAW DD1423-1/Corrected in Amendment – 0001 by contracting

1. Noted Clause 52.246-2 Inspection of Supplies was used rather than 52.246-4 Inspection of Services? Not sure where this clause comes from? Contracting / Tim Howard – Added 52.246-4 Inspection of Services and deleted 52.246-2 Inspection of Supplies.

1. Section 4.4 of the PWS requests immediate return of CND/RTOK units, however there is not a CLIN for this service. Removed this Section, this unit will not require CND/RTOK – updated PWS attached.