2d Rd of Questions and Answers - FA8251-21-Q-0004-0001.docx
DOCX document 20 KB Posted
- Attached to
- F-16 A/B HUD - PDU Repairs
- Solicitation number
- FA8251-21-Q-0004
View the file
Other files
| File | Type | Posted |
|---|---|---|
| FA825221Q0004 - Question Set 3.docx | DOCX document | |
| FA825121Q0004_______0002.pdf | ||
| PWS_HUD_PDU_.docx | DOCX document | |
| FA825121Q0004_______0001.pdf | ||
| Questions and Answers- FA8251-21-Q-0004.pdf | ||
| Combined_CDRLs_A001_A002_A004_B001.pdf | ||
| CDRL_B002-IUID_Plan.pdf | ||
| Transportation.pdf | ||
| Packaging.pdf | ||
| RQR.pdf | ||
| PWS HUD PDU FD20202100171.pdf | ||
| Special_Packing_Instructions_1-7.pdf | ||
| WAGE_DET.pdf | ||
| CAV_Instructions.pdf | ||
| FA825121Q0004.pdf |
Show all 15
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
2nd round of Answered Questions 6 May RFQ Close Date 11 May/COB
1. CLIN 0001 BER CLIN - the NSN is incorrect and alternate part number 16VE017001-13 needs to be added. NSN is correct on the PR, including part number 16VE017001-13 – I did add it as an alternate on the PWS though they are the same HUD – updated PWS attached. Corrected in Amendment 0001 by contracting.
1. DATA CLIN 0003 – A003 Government Property Report is missing. I concurred to have this taken out of the recurring data CLIN CAVAF (Recurring Data CAVAF End Item Report A001 Contract Depot Maintenance Monthly Production Report A002 Government, Property Inventory Report A003 Maintenance Data Collection Report A004) I removed it from the PWS.
1. DATA CLINs 0003 & 0004 – Inspection/Acceptance Report states “Receiving Report Required”, however Block 7 of some of the CDRLS requires a letter of transmittal (LT) not (DD). Please correct DATA CLINS Inspection/Acceptance Report to read “IAW DD1423-1. Correct, PR states IAW DD1423-1/Corrected in Amendment – 0001 by contracting
1. Noted Clause 52.246-2 Inspection of Supplies was used rather than 52.246-4 Inspection of Services? Not sure where this clause comes from? Contracting / Tim Howard – Added 52.246-4 Inspection of Services and deleted 52.246-2 Inspection of Supplies.
1. Section 4.4 of the PWS requests immediate return of CND/RTOK units, however there is not a CLIN for this service. Removed this Section, this unit will not require CND/RTOK – updated PWS attached.