Questions and Answers.docx
DOCX document 13 KB Posted
- Attached to
- ITIPS Upgrade Telemetry Front-end Processor Systems Federal contract opportunity
- Solicitation number
- FA822823R0001
About this file
This document contains questions and answers regarding a federal contract opportunity for an ITIPS Upgrade Telemetry Front-end Processor Systems. The opportunity involves upgrading a telemetry front-end processor to process digital PCM signals coming from a TMoIP to PCM converter over approximately 3 feet of cable. Both data and clock signals will be provided in TTL format and should be fairly free of noise, requiring minimal filtering or signal processing. The solicitation number is FA822823R0001 and is being issued by the Department of the Air Force Materiel Command Air Force Sustainment Center.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Questions and Answers.docx | DOCX document | |
| SOW Updated 8.16.23.docx | DOCX document | |
| Combined Solicitation-Synopsis 8.24.23.docx | DOCX document | |
| Combined Solicitation-Synopsis 8.21.23.docx | DOCX document | |
| SOW Updated 8.16.23.docx | DOCX document | |
| SOW Updated 8.16.23.docx | DOCX document | |
| Combined Solicitation-Synopsis 8.16.23.docx | DOCX document | |
| Questions and Answers.pdf | ||
| SOW Updated.docx | DOCX document | |
| Combined Solicitation-Synopsis Updated.docx | DOCX document | |
| 10182 - Combined Solicitation-Synopsis.docx | DOCX document | |
| CDRL A001 Operation and Maintenance Manual.pdf | ||
| Solicitation - FA822823R0001.pdf | ||
| Statement of Work.docx | DOCX document |
Show all 14
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Questions and Answers
Question 1:
What kind of input signals are supplied to the system? Are both clock and data signals provided, and are the signals digital and reasonably free of noise? If digital signals are being provided, what signal levels can be expected – TTL, RS422, LVDS? This question tries to establish whether bits can be reliably captured digitally, potentially with clock recovery in the case of data-only signals, at the clock transitions, or whether some filtering or signal processing is required. Note that SoW item 2.1.8 appears to mention bit sync-related parameters, but otherwise the SoW does not explicitly call out bit sync capability as a requirement. Absent an explicit requirement, we need information about the signals in order to assess this.
Answer 1:
The input to the FEP is a digital PCM signal coming out of a TMoIP to PCM converter over approximately 3 feet of cable. The signal should be fairly free of noise. Both Data and Clock are present. The signal is TTL. Very minimal, if any at all, filtering or digital signal processing should be required.